FG-200 HSE/FF Modbus

Total Page:16

File Type:pdf, Size:1020Kb

FG-200 HSE/FF Modbus User Manual FG-200 HSE/FF Modbus FOUNDATION fieldbus network integration via Modbus including redundancy Version: EN-102015-1.00 © Copyright 2015 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds to the technical status at the time of printing of it and is passed on with the best of our knowledge. The information in these instructions is in no event a basis for warranty claims or contractual agreements concerning the described products, and may especially not be deemed as warranty concerning the quality and durability pursuant to Sec. 443 German Civil Code. We reserve the right to make any alterations or improvements to these instructions without prior notice. The actual design of products may deviate from the information contained in the instructions if technical alterations and product improvements so require. It may not, in part or in its entirety, be reproduced, copied, or transferred into electronic media. Softing Industrial Automation GmbH Richard-Reitzner-Allee 6 85540 Haar / Germany Tel: + 49 89 4 56 56-0 Fax: + 49 89 4 56 56-488 Internet: http://industrial.softing.com Email: [email protected] Support: [email protected] The latest version of this manual is available in the Softing download area at: http://industrial.softing.com. Table of Contents Table of Contents Chapter 1 Intro..d..u..c..t..i.o..n.....................................................................7 1.1 About FG-..2..0..0.. .H..S...E../.F..F.. .M...o..d..b..u..s....................................................... 7 1.2 System re.q..u..i.r.e..m...e..n..t.s....................................................................... 7 1.3 Scope of d..e..l.i.v..e..r.y............................................................................. 7 1.4 Safety pre.c..a..u..t.i.o..n..s........................................................................... 7 1.5 Intended u..s..e.................................................................................... 8 1.6 Document. .h..i.s..t.o..r.y............................................................................. 8 1.7 Conventio.n..s.. .u..s..e..d............................................................................ 8 Chapter 2 Hard..w...a..r.e.. .i.n...s..t.a..l.l.a..t.i.o..n......................................................9 2.1 Installation.. .i.n.. .h..a..z..a..r.d..o..u..s.. .l.o..c.a..t.i.o..n..s................................................... 9 2.2 Mounting.. .a..n..d.. .d..i.s.m...o..u..n..t.i.n..g............................................................. 12 2.3 Connecti.o..n.. .d..i.a..g..r.a..m........................................................................ 13 2.4 Connect .t.h..e.. .p..o..w...e..r. .s..u..p..p..l.y............................................................. 13 2.5 Connect .t.o.. .n..e..t.w...o..r.k........................................................................ 14 2.6 Modbus .s..e..r.i.a..l .c..o..n..n..e..c..t.i.o..n.............................................................. 14 2.7 Use two .F..G...-.2..0..0..s.. .a..s.. .a.. .r.e..d..u..n..d..a..n..t. .s..e..t........................................... 14 2.8 Connect .F...F..-.H...1.. .in..t.e..r..f.a..c.e..s.............................................................. 15 2.9 Power up.. .t.h..e.. .d..e..v..i.c..e...................................................................... 16 2.10 Add a se.c..o..n..d.. .F..G...-.2..0..0.. .t.o.. .f.o..r.m... .a.. .r..e..d..u..n..d..a..n..t. .s.e..t. .o..f. .F...G..-..2..0..0............ 17 Chapter 3 Co.m...m...i.s..s..i.o..n..i.n...g.. .t.h..e.. .F..G...-.2..0..0.. .H...S..E../.F..F... .M...o..d..b..u..s..............18 3.1 Install FF..-.C...O..N...F............................................................................. 18 3.2 Configur.e.. .I.P.. .a..d..d..r.e..s..s.. .a..n..d.. .M...o..d..b..u..s.. .p..a..r.a..m...e..t.e..r.s............................. 18 Chapter 4 Wo..r.k..i.n..g.. .w...i.t.h.. .t..h..e.. .F..G...-.2..0..0.. .H..S...E../.F..F.. .M...o...d..b..u..s..................20 4.1 FG-200 a..c..t.s.. .a..s.. .a.. .M...o..d..b..u..s. ./. .F...F..-.H..1.. .G...a..t.e..w...a..y................................. 20 4.1.1 FG-20.0.. .a..c..t.s.. .a..s.. .li.n..k.. .a..c..t.i.v.e.. .s..c..h..e..d..u..l.e..r............................................ 20 4.1.1.1 Configuration with F..F..-.C...O...N..F.......................................................... 21 4.1.1.1.1 The H1 field devic.e..s.. .a..r.e.. .p..r.e..-.c..o..n..f.i.g..u..r.e..d........................................ 21 4.1.1.1.2 The H1 field devic.e..s.. .a..r.e.. .n..o..t. .c.o..n..f..ig..u..r.e..d../.n..o..t. .a..v..a..i.l.a..b..l.e.. .y.e..t............. 26 4.1.2 FG-20.0.. .a..c..t.s.. .a..s.. .v.i.s..i.t.o..r. .h..o..s..t........................................................... 31 4.1.3 Config.u..r..e.. .t.h..e.. .M...o..d..b..u..s. .m...a..p..p..i.n..g.. .t.a..b..l.e............................................ 31 FG-200 HSE/FF Modbus - User Manual 3 Table of Contents 4.1.4 Modbu..s.. .s..t.a..t.is..t.i.c..s.. .c.o..u..n..t.e..r.............................................................. 36 4.2 FG-200 a..c..t.s.. .a..s.. .a.. .F..F..-.H...S..E.../. .F..F..-.H...1.. .g..a..t.e..w..a..y................................... 37 4.2.1 FG-200 acts as an H1 interface used by Emerson AMS System............................................................................................ 37 Chapter 5 Us.i.n..g.. .t.h..e.. .i.n..t..e..r.n..a..l. .w...e..b..s..e..r.v..e..r.. .i.n..t.e..r.f..a..c..e.......................39 5.1 Login to .w..e..b..s..e..r.v..e..r........................................................................ 39 5.2 Informati.o..n.. .m...e..n..u........................................................................... 40 5.3 Diagnost.i.c..s.. .m...e..n..u.......................................................................... 41 5.3.1 System............................................................................................ 41 5.3.2 Interne..t. .P...r.o..t.o..c..o..l........................................................................... 41 5.3.3 Fieldb.u..s......................................................................................... 42 5.3.4 Advan.c..e..d....................................................................................... 42 5.4 Monitor m...e..n..u................................................................................. 43 5.4.1 Point P...a..g..e..s. .s..u..b..m...e..n..u.................................................................... 43 5.4.2 Point D...a..t.a.. .s..u..b..m...e..n..u...................................................................... 43 5.5 Configur.a..t.io..n.. .m...e..n..u........................................................................ 44 5.5.1 Setting..s.......................................................................................... 44 5.5.1.1 General Settings su..b..m...e..n..u............................................................ 44 5.5.1.2 Internet Protocol su..b..m...e..n..u............................................................ 46 5.5.1.3 LD Settings submen..u..................................................................... 47 5.5.1.4 User Accounts subm...e..n..u................................................................ 47 5.5.2 System... .M...a..i.n..t.e..n..a..n..c..e..................................................................... 48 5.5.2.1 Restart submenu ....................................................................... 48 5.5.2.2 Firmware submenu....................................................................... 48 5.5.2.3 Configuration Backu..p.. .s..u..b..m...e..n..u..................................................... 49 5.5.2.4 Time submenu ....................................................................... 50 5.5.3 Page O...p..t.i.o..n..s................................................................................. 51 5.5.3.1 Point Pages subme.n..u.................................................................... 51 5.5.3.2 Point Columns subm...e..n..u................................................................ 53 5.5.3.3 Homepage submen.u...................................................................... 53 5.5.4 Fieldb.u..s......................................................................................... 53 5.5.4.1 Devices submenu ....................................................................... 54 5.5.4.2 Blocks submenu ....................................................................... 54 5.5.4.3 H1 Busparameter s.u..b..m...e..n..u........................................................... 55 5.5.4.4 HSE submenu ....................................................................... 56 4 FG-200 HSE/FF Modbus - User Manual Table of Contents 5.5.5 Modbu..s.......................................................................................... 56 5.5.5.1 Communication sub..m...e..n..u.............................................................. 56 5.5.5.2 Mapping submenu ....................................................................... 57 5.5.5.3 Import/Export subm.e..n..u.................................................................. 58 Chapter 6 Re.d..u..n..d..a..n..c..y.. .m...o...d..e........................................................59 6.1 Redunda..n..c.y.. .c..o..n..c..e..p..t.................................................................... 59 6.2 Fault
Recommended publications
  • Installing Fieldbus Installing Fieldbus
    Installing Fieldbus Installing Fieldbus Many automation engineers are coming face-to-face Figure 1. Standard FOUNDATION fi eldbus™ Segment. with fi eldbus applications for the fi rst time. Fieldbus (the use of digital communications for distributed Operator instrumentation and control networks) is an established Workstation technology with many benefi ts. However, fi eldbus installations require some additional considerations over and above traditional 4-20mA projects. High Speed Ethernet Choosing a “Fieldbus” Control System Fieldbus is a generic term for a variety of with H1/PA communications protocols using various media, but Interface all are simply a means to an end. What you want DC Power at commission of the project is a satisfactory and Input functional control system, and it is likely you will need Fieldbus DC to use multiple fi eldbuses to accomplish the many tasks Power Supply (Conditioner) required. For example, you may use FOUNDATION 350-500mA (Not Required for fi eldbus™ for process control, DeviceNet for discrete Fieldbus T PA Systems; May Be I/O, and PROFIBUS DP for motor drives. Every DCS Terminator with the Control System Interface) can easily integrate all of these functional plant buses into the control room Ethernet-based network. FOUNDATION fieldbus H1 or PROFIBUS PA In the process control world, “fi eldbus” usually Network (Twisted Wire Pair) 1,900m (6,233 ft) Maximum means FOUNDATION fi eldbus H1 or PROFIBUS PA. Segment Length Including Both are widely used around the world in refi neries Spur Lengths and process plants as modern day enhancements to Fieldbus Trunk Out traditional 4-20mA designs.
    [Show full text]
  • Foundation Fieldbus Overview
    FOUNDATIONTM Fieldbus Overview Foundation Fieldbus Overview January 2014 370729D-01 Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal to access the branch office Web sites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100 For further support information, refer to the Technical Support and Professional Services appendix. To comment on National Instruments documentation, refer to the National Instruments website at ni.com/info and enter the Info Code feedback. © 2003–2014 National Instruments. All rights reserved. Legal Information Warranty NI devices are warranted against defects in materials and workmanship for a period of one year from the invoice date, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor. The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in materials and workmanship, for a period of 90 days from the invoice date, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free. A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any equipment will be accepted for warranty work.
    [Show full text]
  • AIT Presentation
    Distributed Sensors & Connectivity as the answer to future grid requirements Karl-Heinz Mayer Director Engineering Innovation & Program Management AIT Industry Day – September 11th, 2015 © 2015 Eaton Corporation. All rights reserved. Power business – status quo • Electricity is still the backbone and driver of mankind‘s productivity – this seems not to be changed soon 2 © 2015 Eaton Corporation. All rights reserved. 2 Power business – status quo • Electricity is still the backbone and driver of mankind‘s productivity – this seems not to be changed soon • Climate changes are requesting less CO2 emission despite the worldwide increase of power demand Green Energy; programs for ISO 50001, LEED,…certifications 3 © 2015 Eaton Corporation. All rights reserved. 3 Power business – status quo • Electricity is still the backbone and driver of mankind‘s productivity – this seems not to be changed soon • Climate changes are requesting less CO2 emission despite the worldwide increase of power demand Green Energy; programs for ISO 50001, LEED,…certifications • Consumer – Prosumer transformation requests new system approaches Virtual power plants 4 © 2015 Eaton Corporation. All rights reserved. 4 Technology trends are lowering the hurdles to develop and connect more intelligent devices • Semiconductor component costs continue to decline • Functionality and power management performance improving • Pervasiveness of communications increasing • Cloud services and development tools are being used more and more…and their costs are dropping dramatically with scale 5 © 2015 Eaton Corporation. All rights reserved. 5 Future challenges 1. Growing Electricity 2. Electricity Peak 3. Increasing Variable 4. Increasing Demand & Ageing Management Energy Generation Integration of Electric Infrastruture Vehicle World Energy Consumption by fuel type, 1990-2040 - Source : EIA (2013) 6 © 2015 Eaton Corporation.
    [Show full text]
  • FOUNDATION Fieldbus Design Considerations Reference Manual
    Reference Manual PlantPAx Process Automation System: FOUNDATION Fieldbus Design Considerations Catalog Numbers 1757-FFLDx, 1757-FFLDCx Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.
    [Show full text]
  • Foundation Fieldbus Components
    Home FOUNDATION FIELDBUS COMPONENTS ◤ Product Series Page WebCode bus-Carrier bus-Carrier 9419 275 9419A Diagnosis Communication Module Diagnosis Communication Module 9415 272 9415A Fieldbus Power Supply Fieldbus Power Supply 9412 269 9412A Fieldbus Terminator Fieldbus Terminator 9418 287 9418A Field Device Coupler Ex i Field Device Coupler 4 Spurs 9411/21 277 9411C Ex i Field Device Coupler 4 Spurs 9411/24 281 9411E Ex i Field Device Coupler 8 Spurs 9411/21 279 9411D Ex i Field Device Coupler 8 Spurs 9411/24 283 9411F Ex n Field Device Coupler 9410 285 9410A General General 268 Overview Overview of Functions ISbus 267 Overview of System Components 267 For additional products and information please refer to r-stahl.com 266 FOUNDATION FIELDBUS COMPONENTS Apr 9, 2020· PK·en-US Overview of System Components Home Overview of the System Components 09 Overview of Functions ISbus Field device coupler 9410/34 9411/24 9411/21 Field device Installation Cl. I, Div. 2, Zone 2 Cl. I, Div. 2, Zone 2 Cl. I, Div. 2, Zone 1 FISCO/Entity (ia, ib) Cl. I, Div. 2, Zone 0/1 x x Cl. I, Div. 2, Zone 2 x FISCO/Entity (ic) Cl. I, Div. 2, Zone 2 x*) x Ex ic (entity) Cl. I, Div. 2, Zone 2 x*) x Ex d/q/m Cl. I, Div. 2, Zone 2 x Cl. I, Div. 2, Zone 2 x Ex nA Cl. I, Div. 2, Zone 2 x Ex i solenoid valve Cl. I, Div. 2, Zone 0/1 Ex i contact Cl. I, Div.
    [Show full text]
  • Foundation Fieldbus Physical Medium, Cabling and Installation
    smarwww.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp Introduction INTRODUCTION FOUNDATION™ fieldbus (FF) is an open architecture to integrate information, whose main objective is to interconnect control devices and industrial automation, distributing the control functions for the network and supplying information to all the layers of the system. The FOUNDATION™ fieldbus technology substitutes with advantages the 4-20mA + HART traditional, technology making possible the bi-directional communication among the devices in a more efficient way. This technology is much more than a protocol of digital communication or a local network to field instruments. It includes several technologies, such as distributed processing, advanced diagnosis and redundancy. A FOUNDATION™ fieldbus system is heterogeneous and distributed, composed by field devices, configuration and supervision software, communication interfaces, power supply and by its own physical network that interconnects them. One of the functions of the field devices is to execute the user application of control and supervision distributed by the network. This is the big difference between FOUNDATION™ fieldbus and other technologies that depend on a central controller to execute the algorithms. Compared to other systems, FOUNDATION™ fieldbus allows the access to many variables, not only related to the process, but also diagnostics of sensor and actuator, electronic components,
    [Show full text]
  • Protocol Selection Table
    Protocol Selection Table Bender offers signal line protection devices for many different communication and signal protocols. Use the table below to know which protectors must be used for a good surge protection. Selection table Protocol Signal Bender Surge protector I/O ± 5 VDC, < 250kHz NSL7v5-G NSLT1-7v5 I/O ± 12 VDC, < 250kHz NSL18-G NSLT1-18 I/O ± 24 VDC, < 250kHz NSL36-G NSLT1-36 I/O 0-20mA / 4-20mA NSL420-G NSLT1-36 I/O RS-232 NSL-DH I/O RS-422 NSL485-EC90 (x2) I/O RS-452 NSL485-EC90 (x2) I/O RS-485 NSL485-EC90 I/O 1-Wire NSL485-EC90 Protocol Signal Bender Surge protector 10/100/1000BaseT Ethernet NTP-RJ45-xCAT6 AS-i 32 VDC 1-pair NSL36-G NSLT1-36 BACnet ARCNET / Ethernet / BACnet/IP NTP-RJ45-xCAT6 BACnet RS-232 NSL-DH BACnet RS-485 NSL485-EC90 BitBus RS-485 NSL485-EC90 CAN Bus (Signal) 5 VDC 1-Pair NSL485-EC90 C-Bus 36 VDC 1-pair NSSP6A-38 CC-Link/LT/Safety RS-485 NSL485-EC90 CC-Link IE Field Ethernet NTP-RJ45-xCAT6 CCTV Power over Ethernet NTP-RJ45-xPoE DALI Digital Serial Interface NSL36-G NSLT1-36 Data Highway/Plus RS-485 NSL485-EC90 DeviceNet (Signal) 5 VDC 1-Pair NSL7v5-G NSLT1-7v5 DF1 RS-232 NSL-DH DirectNET RS-232 NSL-DH DirectNET RS-485 NSL485-EC90 Dupline (Signal) 5 VDC 1-Pair NSL7v5-G NSLT1-7v5 Dynalite DyNet NTP-RJ45-xCAT6 EtherCAT Ethernet NTP-RJ45-xCAT6 Ethernet Global Data Ethernet NTP-RJ45-xCAT6 Ethernet Powerlink Ethernet NTP-RJ45-xCAT6 Protocol Signal Bender Surge protector FIP Bus RS-485 NSL485-EC90 FINS Ethernet NTP-RJ45-xCAT6 FINS RS-232 NSL-DH FINS DeviceNet (Signal) NSL7v5-G NSLT1-7v5 FOUNDATION Fieldbus H1
    [Show full text]
  • Foundation™ Fieldbus
    Compliments of: The Fieldbus Foundation © 2003-2004 Fieldbus Foundation ™ FOUNDATION Fieldbus System Engineering Guidelines (AG-181) Revision 2.0 This preface, as well as all footnotes and annexes, is included for information purposes and is not part of AG-181. This document has been prepared under the direction of the End User Advisory Council (EUAC) of the Fieldbus Foundation. To be of real value, it should not be static but should be subject to periodic review. Toward this end, the foundation welcomes all comments and criticisms and asks that they be addressed to: Chairman End User Advisory Council Fieldbus Foundation 9005 Mountain Ridge Drive Bowie Building - Suite 190 Austin, Texas 78759-5316 USA Tel: 512.794.8890 Fax 512.794.8893 E-mail: [email protected] Visit our Worldwide Web Site: www.fieldbus.org This document in its present revision and at time of publication recognizes that High Speed Ethernet (HSE) products are available from the Fieldbus Foundation and its members. The next revision of this document will incorporate guidelines for the installation and implementation of HSE. The use of specific Vendor/Manufacturers in this document does not entail implicit endorsement of the product over other similar products by the authors or the Fieldbus Foundation. Individuals using this document are encouraged to seek out equivalent function equipment from other sources of which the authors may be unaware. To assist in our efforts to make this document as relevant as possible, should such equipment be known to a user of this document please forward that information to the address given above.
    [Show full text]
  • IEC61158 Technology Comparison State of the Bus Fieldbus Inc
    IEC61158 Technology Comparison State of the Bus Fieldbus Inc. • Provides vendor-neutral fieldbus solutions to End Users, Device Vendors, and Others needing additional fieldbus expertise • For Device Vendors FI can provide: Development tools such as stacks and function blocks Starter Kits Training Customized software and hardware Complete drop-in solutions • For End Users FI can provide: Training System Preparation (RFQ, scope, choosing host system and devices) System Design Installation Assistance System Configuration Assistance Commissioning Assistance Long Term Support (Improve diagnostics, make use of fieldbus data, trouble- shooting, process refinement) Fieldbus Inc. Contact Information Fieldbus Inc. 9390 Research Blvd., Suite I-350 Austin, Texas USA 78759 +1.512.794.1011 www.fieldbusinc.com [email protected] Purpose • Motivation for fieldbus projects • Technical analysis of IEC 61158/61184 • Criteria for fieldbus standard technologies • Comparison of process fieldbus technologies • Technical merits • Global significance • Market for fieldbus Fieldbus defined • fieldbus - an industrial network system for real-time distributed control. • fieldbus - any open, digital, multi-drop communications network for intelligent field devices Viable Standardized Technology • International recognition • Market significance • Global availability (global install base) • Suppliers • Support organizations (local and international) FIELDBUS MOTIVATION 7 The Justification For Fieldbus Well Established • Lower Project cost – helps with
    [Show full text]
  • Signalling Protocols
    Signalling Protocols Table 1 outlines some of the most common signalling protocols along with the Novaris surge protection product best suited to your application. For other signalling protocols please contact Novaris to discuss your protection requirements. Protocol Signal Type Novaris Product I/O ± 5 VDC, < 250kHz SL7v5-G SLT1-7v5 I/O ± 12 VDC, < 250kHz SL18-G SLT1-18 I/O ± 24 VDC, < 250kHz SL36-G SLT1-36 I/O ± 48 VDC, < 250kHz SL68-G SLT1-68 I/O 0-20mA / 4-20mA SL420-G SLT1-36 I/O RS-232 DB9-RS232 DB25-RS232 SL-DH I/O RS-422 SL485-EC90 (x2) DB9-RS485 I/O RS-452 SL485-EC90 (x2) DB9-RS485 I/O RS-485 SL485-EC90 DB9-RS485 I/O 1-Wire SL485-EC90 DB9-RS485 10/100/1000BaseT Ethernet RJ45-xCAT6 AS-i 32 VDC 1-pair SL36-G SLT1-36 BACnet ARCNET / Ethernet / BACnet/IP RJ45-xCAT6 BACnet RS-232 DB9-RS232 DB25-RS232 SL-DH BACnet RS-485 SL485-EC90 DB9-RS485 BitBus RS-485 SL485-EC90 DB9-RS485 CAN Bus (Signal) 5 VDC 1-Pair SL-DH DB9-RS232 C-Bus 36 VDC 1-pair SSP6A-38 CC-Link/LT/Safety RS-485 SL485-EC90 DB9-RS485 CC-Link IE Field Ethernet RJ45-xCAT6 CCTV Coaxial CLB-MF-10 CCTV Power over Ethernet RJ45-xPoE ControlNet Coaxial CLB-MF-10 DALI Digital Serial Interface SL36-G SLT1-36 Data Highway/Plus RS-485 SL485-EC90 DB9-RS485 DeviceNet (Signal) 5 VDC 1-Pair SL7v5-G SLT1-7v5 DF1 RS-232 DB9-RS232 DB25-RS232 SL-DH DirectNET RS-232 DB9-RS232 DB25-RS232 SL-DH DirectNET RS-485 SL485-EC90 DB9-RS485 Dupline (Signal) 5 VDC 1-Pair SL7v5-G SLT1-7v5 Dynalite DyNet RJ45-xPoE EtherCAT Ethernet RJ45-xCAT6 Ethernet Global Data Ethernet RJ45-xCAT6 Ethernet Powerlink Ethernet
    [Show full text]
  • PLC & Fieldbus Control Systems Automation Guidebook – Part 4
    PDHonline Course E448 (9 PDH) ______________________________________________________________________________ PLC & Fieldbus Control Systems Automation Guidebook – Part 4 Instructor: Jurandir Primo, PE 2014 PDH Online | PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.PDHonline.org www.PDHcenter.com An Approved Continuing Education Provider www.PDHcenter.com PDHonline Course E448 www.PDHonline.org PLC & FIELDBUS CONTROL SYSTEMS AUTOMATION GUIDEBOOK – PART 4 CONTENTS: 1. PLC HISTORY 2. INTRODUCTION 3. INPUT/OUTPUT (I/O) CAPABILITIES 4. LADDER LOGIC PROGRAMS 5. HUMAN-MACHINE INTERFACE (HMI) 6. HOW THE PLCs WORK 7. FIELDBUS CONTROL SYSTEMS 8. DCS AND FIELDBUS DEVELOPMENT 9. FIELDBUS MODELS AND NETWORK STRUCTURE 10. DIAGNOSTICS & COMMUNICATION INTERFACES 11. BASIC COMMUNICATION STANDARDS 12. REFERENCES & LINKS ©2014 Jurandir Primo Page 1 of 101 www.PDHcenter.com PDHonline Course E448 www.PDHonline.org 1. PLC HISTORY The early history of the PLC (Programmable Logic Controller) goes back to the 1960’s when control systems were still handled using relay control. During this time the control rooms consisted of sev- eral walls containing many relays, terminal blocks and mass of wires. In 1968 Bill Stone, who was part of a group of engineers at the Hydramatic Division of General Mo- tors Corporation, presented a paper at the Westinghouse Conference outlining their problems with reliability and documentation for the machines at this plant. He also presented a design criteria de- veloped by the GM engineers for a “standard machine controller”, to eliminate costly scrapping of assembly-line relays. These specifications along with a proposal request to build a prototype were given to four control builders: • Allen-Bradley, by way of Michigan-based Information Instruments, Inc.
    [Show full text]
  • 1756 Controllogix Communication Modules Specifications Technical
    Technical Data 1756 ControlLogix Communication Modules Specifications Standard ControlLogix Catalog Numbers 1756-EN2F, 1756-EN2T, 1756-EN2TR, 1756-EN3TR, 1756-ENBT, 1756-EWEB, 1756-CN2, 1756-CN2R, 1756-CNB, 1756-CNBR, 1756-DNB, 1756-DHRIO, 1756-RIO, 1756-DH485, 1756-SYNCH, 1756-EN2TXT, 1756-CN2RXT, 1756-DHRIOXT, 1757-FFLD2, 1757-FFLD4, 1757-FFLDC2, 1757-FFLDC4 ControlLogix-XT Catalog Numbers 1756-EN2TXT, 1756-CN2RXT, 1756-DHRIOXT Linking Device Catalog Numbers 1757-FFLD2, 1757-FFLD4, 1757-FFLDC2, 1757-FFLDC4 Topic Page Additional Resources 2 Available Communication Modules 2 EtherNet/IP Network 3 Stratix Switches 9 ControlNet Network 10 DeviceNet Network 17 DH+ and Remote I/O Networks 20 FOUNDATION Fieldbus Network 25 DH-485 Network 28 SynchLink Communication 31 Separate communication-interface modules are available for different networks. Install multiple communication-interface modules into the ControlLogix® backplane to configure a gateway to bridge or route control and information data between different networks. You do not need a ControlLogix controller in the chassis. 1756 ControlLogix Communication Modules Specifications Additional Resources These documents contain additional information concerning related products from Rockwell Automation®. Resource Description Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Provides general guidelines for installing a Rockwell Automation industrial system. Product Certifications website, http://www.ab.com Provides declarations of conformity, certificates, and other
    [Show full text]