Thermal Energy Systems — What You Need to Know Increasingly, Building Designers Are Turning to Thermal Energy to Help Deliver Sustainable Outcomes

Total Page:16

File Type:pdf, Size:1020Kb

Thermal Energy Systems — What You Need to Know Increasingly, Building Designers Are Turning to Thermal Energy to Help Deliver Sustainable Outcomes cover story >>> SEAN McGOWAN REPORTS Thermal energy systems — what you need to know Increasingly, building designers are turning to thermal energy to help deliver sustainable outcomes. Thermal energy systems come in many forms, from thermal mass to chilled water storage and phase change materials — and are delivering results in a range of applications. With today’s focus on more responsible building design, including sustainability, occupant health and comfort, indoor air quality and importantly, low energy consumption, thermal energy systems are emerging to play an important role in delivering these outcomes. While some forms of thermal energy have been used by man to provide thermal comfort for hundreds, if not thousands of years, more recent developments are delivering both measurable and sustainable benefits. HVAC&R Nation takes a closer look at five thermal energy systems, and discovers what you really need to know. Thermal mass Thermal mass is the ability of a building material to absorb and store heat, before releasing it at a later time. Therefore when used correctly, it can provide cooling during warmer months, and heating during cooler months. Thurgoona Campus, Charles Sturt University “Thermal mass is the quiet According to Arkins, this process is called the best, but in areas where the diurnal temperature range achiever of the building world,” “thermal flywheel” effect, where the greater the time is small, thermal mass can make internal conditions says Chris Arkins, associate lag of external construction the greater the effectiveness worse by radiating all the heat at nighttime during with Steensen Varming of the mass. a heat wave, and absorbing all the heat you produce on a winter night. Australia. Thermal mass influences the internal temperature within a building by providing heat sink surfaces for Thurgoona Campus, Charles radiation, conductive and convective heat exchange; by “It has characteristics that when understood and applied providing a time lag between peak external and internal Sturt University, Albury Australia in an appropriate manner can provide opportunities not temperatures and by providing a reduction in heat Experiencing hot windy summers, the Thurgoona commonly available through more traditional systems transfer across an external wall. Campus of Charles Sturt University in Albury has used and design approaches.” thermal mass to hold warmth in winter and coolth in Thermal mass can also be used in mixed mode to summer. Rammed earth exterior and internal walls Building materials of high density, such as concrete, reduce air conditioning loads, with the most common between 300mm and 600mm have been employed, bricks and tiles are said to have a high thermal mass, application being a nighttime purge cycle to precool along with concrete floor slabs and suspended slabs while those which are lightweight such as timber have the building mass and remove overnight residual internal to upper floors and ceilings. a low thermal mass. Therefore by using materials with a heat gains. high thermal mass, and positioning them in such a way The campus’s main lecture theatre is buried under that they make the most of the sun’s radiation at the “Energy savings are then realised through reduced a grassed mound to take advantage of the thermal right times of the year, thermal benefits can be exploited. morning pull down loads plus the convective cooling properties of the earth around it, moderating heat offered by the storage capacity of the mass,” says Arkins, losses and protecting it from extreme ambient heat, As the summer sun is positioned high in the sky, and the adding that in commercial CBD buildings, this can while many of the buildings use stack-induced natural winter sun is positioned lower, shading techniques can typically only be achieved through mechanical means; ventilation created by thermal chimneys. moderate the thermal effects of the summer sun, and with the fan power required often offsetting the energy maximise the heat gain in winter when the sun is lower. savings achieved. Thermal mass in a building acts as a thermal battery, Decoupled thermal mass or thermal sink – whereby in summer it absorbs heat, Where it works Decoupled thermal mass storage is a term used to describe keeping the space comfortable, while in winter the In areas that experience a large diurnal temperature situations where thermal mass is accessed outside the same thermal mass can store the heat from the sun and range (that is, a large difference between daytime building envelope, such as the earth below the building, release it during the night. and nighttime temperatures), thermal mass works or depending on location, water from a river, lake or ocean. www.hvacrnation.com.au September 2008 HVAC&R Nation 19 Federation Square, Melbourne The two most common applications of decoupled around the world, where it can reduce first costs in some thermal mass are labyrinth systems which consist of cases, as well as increase lettable space. tunnels built from a high thermal mass material that “The use of low temperature water from ice storage use air to transfer the thermal storage capacity of allows savings in piping, pumps and air handling the labyrinth to the building; and geothermal heat equipment,” explains Ramez Naguib, international exchangers that provide access to substantial thermal marketing manager for Baltimore Aircoil Company. mass, with water used as the medium to transfer energy to and from the building to the earth. Ice thermal storage systems generally produce ice at night taking advantage of off-peak electrical tariffs, and Labyrinth designs are particularly effective in exploiting therefore helping to reduce peak demand on electrical the diurnal temperature variations of a location to supply. This ice is then stored until cooling is required, at Federation Square labyrinth provide low energy cooling. For example, Australia’s which time water is circulated through the ice storage largest labyrinth lies under Melbourne’s Federation area before being distributed to the system to provide operational hours to cool the Atrium via a low velocity Square and is 1600m² in size and 1.2 kilometres in length. space cooling. displacement system at floor level, as well as provide These systems work by flooding the labyrinth with environmental climate control and act as a pre-cooling An ice storage system offers two major benefits. Firstly, cool night air, which in turn cools the high thermal system for other areas of the complex. it can take advantage of off-peak electrical tariffs, mass material. During the day, air is drawn through the and secondly, it can reduce the chilled water flow “In peak summer conditions, the labyrinth is capable labyrinth where it is cooled before entering the building. requirements by half. In winter, the process is generally reversed. of delivering air to the Atrium at up to 12°C below the external ambient temperature, equivalent to “An ice storage system with supply and return water Where it works conventional air conditioning, but using one tenth of the temperatures of 2°C and 13°C versus a traditional system energy consumption and generating less than one tenth using 7°C to 13°C requires almost half the water flow, Again, decoupled thermal mass systems take advantage of the CO² emissions,” explains Arkins. pump BHP and smaller pipes,” says Naguib. of large diurnal temperature ranges, so areas that experience this type of climate are prime candidates Other installations “In addition, when low temperature air distribution for this system. is also used, additional savings are realised from • The Earth Centre, Doncaster U.K. smaller ductwork, smaller fans as well as less energy Federation Square, • National Museum of World Cultures, Gothenburg consumption and increased usable space.” Melbourne Australia Sweden The fact that this system has traditionally been an open Below Melbourne’s Federation Square lies a 1600m² loop has delayed its widespread adoption, however new concrete labyrinth which provides energy efficient Ice storage ice-on-coil technology allows designers to have a closed cooling and heating to the complex’s Atrium and other loop system. areas. Using ice for thermal comfort has been used for In Australia, however, such systems have not proven centuries, and not just by the Eskimos. It works by pulling the cool night air off the adjacent popular, with only handful of older buildings using the Yarra River through the labyrinth, which in turn cools In modern times, ice thermal storage has been system. While electricity suppliers prefer the system down the thermal mass walls, and is used during successfully implemented in many building projects because of its use of off-peak electricity, its high 20 HVAC&R Nation September 2008 www.hvacrnation.com.au energy requirements mean it’s unlikely to be popular anytime soon. Where it works Ice storage has been used effectively in major projects around the world, including the U.S.A. and Japan where its use in district cooling projects is both popular and effective. In Australia its use is limited. Centex Building, Dallas Texas, U.S.A. The Centex Building in Dallas is one of the United States’ most energy efficient buildings, thanks largely to its ice storage system. By combining the use of fourteen ice tanks with two high efficiency electric rotary water- cooled chillers, the normal peak electrical load of a building such as this has been dramatically reduced. The chillers cool a glycol solution to – 4°C to produce ice in the storage tanks, which are then used for eight hours starting from noon to provide efficient cooling to the building while using only one chiller. This partial ice storage system provides up to 7400kWh of cooling capacity, with the melting ice providing 40% of the building’s cooling requirements on a 38°C day, and a much higher percentage during cooler months.
Recommended publications
  • IRITS-0313-040 EUEN 0518 DEC Refrigerated Dryer Datasheet.Indd
    Dec High-Efficiency Cycling Dryers 42-5,400 m3/hr Achieve maximum energy savings, while ensuring a continuous supply of dry high-quality air. increase reliability. Features such as dryer self-regulation and plug-and-play installation make start-up convenient, while readily-available parts make ongoing maintenance simple and easy. Advanced Environmental Sustainability By shutting off the compressor during low loads, Dec dryers dramatically reduce energy waste. Dec dryers use R134a and R407c refrigerants that are environmentally-friendly with low global warming potential to help reduce greenhouse gas emissions. High-quality components provide longer lasting dryers that require fewer replacement parts, minimising environmental impact. Higher Efficiency, Lower Cost The high-efficiency design and construction of Ingersoll Energy Savings by Technology Rand Dec cycling dryers helps you achieve better 4.0 performance, while reducing energy consumption. The Dec Dryer 3.5 patented high-efficiency heat exchanger, combined with Non-Cycling 3.0 Dryers a thermal mass circuit, helps save energy at any load. The kW 2.5 Variable Speed highly efficient refrigerant compressor is automatically Drive Dryers 2.0 deactivated to save energy when not needed. 1.5 Energy Savings Consumption 1.0 Reliability and Simplicity through Experience 0.5 Utilising extensive dryer design experience, the Ingersoll Rand 0.0 Dec dryer includes features like microprocessor control 02025507580100 and a heavy-duty electronic no-loss (ENL) drain that % Load Efficiency Is the Bottom Line The Dec dryer’s efficient design and construction are evident in terms of superior air quality and throughput with a lower Low Operating Cost cost of operation.
    [Show full text]
  • Thermal Mass
    Thermal Mass • What is Thermal Mass? • Types of Thermal Mass • Historical Applications • Thermal Properties of Materials • Analyzing Heat/Cool Storage • Strategies • Other Factors • Computer Analysis • Bibliography Thermal Mass • Thermal mass refers to materials have the capacity to store thermal energy for extended periods. • Thermal mass can be used effectively to absorb daytime heat gains (reducing cooling load) and release the heat during the night (reducing heat load). Types of Thermal Mass • Traditional types of thermal mass include water, rock, earth, brick, concrete, fibrous cement, caliche, and ceramic tile. • Phase change materials store energy while maintaining constant temperatures, using chemical bonds to store & release latent heat. PCM’s include solid-liquid Glauber’s salt, paraffin wax, and the newer solid-solid linear crystalline alkyl hydrocarbons (K-18: 77oF phase transformation temperature). PCM’s can store five to fourteen times more heat per unit volume than traditional materials. (source: US Department of Energy). Historical Applications • The use of thermal mass in shelter dates back to the dawn of humans, and until recently has been the prevailing strategy for building climate control in hot regions. Egyptian mud-brick storage rooms (3200 years old). The lime-pozzolana (concrete) Roman Pantheon Today, passive techniques such as thermal mass are ironically considered “alternative” methods to mechanical heating and cooling, yet the appropriate use of thermal mass offers an efficient integration of structure and thermal services. Thermal Properties of Materials The basic properties that indicate the thermal behavior of materials are: density (p), specific heat (cm), and conductivity (k). The specific heat for most masonry materials is similar (about 0.2-0.25Wh/kgC).
    [Show full text]
  • A Simplified Ground Thermal Response Model for Analyzing
    1 A Simplified Ground Thermal Response 2 Model for Analyzing Solar-Assisted Ground 3 Source Heat Pump Systems 4 5 6 7 8 9 10 Jamie P. Fine, Hiep V. Nguyen, Jacob Friedman, Wey H. Leong, and Seth B. Dworkin* 11 12 Department of Mechanical and Industrial Engineering 13 Ryerson University 14 350 Victoria Street, Toronto, Canada 15 (*Corresponding author: [email protected]) 16 17 Abstract 18 19 Ground source heat pump systems that are installed in areas with heating or cooling dominant 20 seasons, or in buildings with utilization characteristics that lead to a disparity in demand, often 21 encounter challenges related to ground thermal imbalance. This imbalance can lead to long-term 22 ground temperature changes and may cause premature system failure. This paper focuses on 23 combining a ground source heat pump system with a solar thermal array, with the goal of 24 eliminating the effect of ground thermal imbalance, and minimizing system lifetime cost. A 25 thermal mass ground heat transfer model is combined with a time-stepping model to analyze the 26 system for a variety of solar array sizes. The details associated with this modelling technique are 27 presented, and case studies are provided to illustrate the results of the calculations for three 28 different buildings. It is shown that increasing the solar array size can offset ground thermal 29 imbalances, but increasing the array size also results in a larger initial system cost. An economic 30 analysis is then carried out to determine the system lifetime cost as a function of this solar array 31 size, and an optimal array size from an economic perspective was found.
    [Show full text]
  • A Comprehensive Review of Thermal Energy Storage
    sustainability Review A Comprehensive Review of Thermal Energy Storage Ioan Sarbu * ID and Calin Sebarchievici Department of Building Services Engineering, Polytechnic University of Timisoara, Piata Victoriei, No. 2A, 300006 Timisoara, Romania; [email protected] * Correspondence: [email protected]; Tel.: +40-256-403-991; Fax: +40-256-403-987 Received: 7 December 2017; Accepted: 10 January 2018; Published: 14 January 2018 Abstract: Thermal energy storage (TES) is a technology that stocks thermal energy by heating or cooling a storage medium so that the stored energy can be used at a later time for heating and cooling applications and power generation. TES systems are used particularly in buildings and in industrial processes. This paper is focused on TES technologies that provide a way of valorizing solar heat and reducing the energy demand of buildings. The principles of several energy storage methods and calculation of storage capacities are described. Sensible heat storage technologies, including water tank, underground, and packed-bed storage methods, are briefly reviewed. Additionally, latent-heat storage systems associated with phase-change materials for use in solar heating/cooling of buildings, solar water heating, heat-pump systems, and concentrating solar power plants as well as thermo-chemical storage are discussed. Finally, cool thermal energy storage is also briefly reviewed and outstanding information on the performance and costs of TES systems are included. Keywords: storage system; phase-change materials; chemical storage; cold storage; performance 1. Introduction Recent projections predict that the primary energy consumption will rise by 48% in 2040 [1]. On the other hand, the depletion of fossil resources in addition to their negative impact on the environment has accelerated the shift toward sustainable energy sources.
    [Show full text]
  • Cycling Refrigerated Air Dryers — Are Savings Significant?
    | 11/11 SUSTAINABLE MANUFACTURING FEATURES CYCLING REFRIGERATED AIR DRYERS — ARE SAVINGS SIGNIFICANT? BY TIMOTHY J. FOX AND RON MARSHALL FOR THE COMPRESSED AIR CHALLENGE® One of the many tasks in assessing a compressed air system supply refrigerated dryers that have different energy implications, especially side is to analyze the air treatment system for appropriateness and when the dryers are subject to partial heat and moisture loading. In efficiency. Most compressed air systems have one or more air dryers order to make a good choice in terms of energy efficiency, the purchaser in place to remove the water vapor contained in the compressed air should take care in understanding the operating characteristics of the produced by the system air compressors. If there is no air dryer, the different refrigerated dryer options available. normally hot saturated air produced by the air compressors will cool Air compressors consume the majority of the power required by a in downstream system components, and condensed water will form in compressed air system; a well running system requiring between 18 and pressurized system pipework. This water may contaminate downstream 22 kW of energy input per 100 scfm of air produced at a compressor air-powered tools and production machinery with rust, oil and pipe discharge pressure of about 100 psig (kW/100 cfm is called specific debris. Refrigerated style dryers are typically used in industrial plants power). Fully loaded refrigerated air dryer specific power levels range to process general industrial compressed air that would be use by tools between 0.6 and 0.8 kW per 100 scfm, or about 3 to 4% of the total and pneumatic machinery.
    [Show full text]
  • Analysis and Comparison of Some Low-Temperature Heat Sources for Heat Pumps
    Article Analysis and Comparison of Some Low-Temperature Heat Sources for Heat Pumps Pavel Neuberger * and Radomír Adamovský Department of Mechanical Engineering, Faculty of Engineering, Czech University of Life Sciences Prague, Kamýcká 129, 165 21 Prague-Suchdol, Czech Republic; [email protected] * Correspondence: [email protected]; Tel.: +420-224-383-179 Received: 12 April 2019; Accepted: 13 May 2019; Published: 15 May 2019 Abstract: The efficiency of a heat pump energy system is significantly influenced by its low- temperature heat source. This paper presents the results of operational monitoring, analysis and comparison of heat transfer fluid temperatures, outputs and extracted energies at the most widely used low temperature heat sources within 218 days of a heating period. The monitoring involved horizontal ground heat exchangers (HGHEs) of linear and Slinky type, vertical ground heat exchangers (VGHEs) with single and double U-tube exchanger as well as the ambient air. The results of the verification indicated that it was not possible to specify clearly the most advantageous low- temperature heat source that meets the requirements of the efficiency of the heat pump operation. The highest average heat transfer fluid temperatures were achieved at linear HGHE (8.13 ± 4.50 °C) and double U-tube VGHE (8.13 ± 3.12 °C). The highest average specific heat output 59.97 ± 41.80 W/m2 and specific energy extracted from the ground mass 2723.40 ± 1785.58 kJ/m2·day were recorded at single U-tube VGHE. The lowest thermal resistance value of 0.07 K·m2/W, specifying the efficiency of the heat transfer process between the ground mass and the heat transfer fluid, was monitored at linear HGHE.
    [Show full text]
  • Thermal Autonomy As Metric and Design Process
    Thermal Autonomy as Metric and Design Process Brendon Levitt. Author Loisos + Ubbelohde, Alameda, California California College of the Arts, San Francisco M. Susan Ubbelohde. Co-Author Loisos + Ubbelohde, Alameda, California University of California, Berkeley George Loisos. Co-Author Loisos + Ubbelohde, Alameda, California Nathan Brown. Co-Author Loisos + Ubbelohde, Alameda, California California College of the Arts, San Francisco ABSTRACT: Metrics for quantifying thermal comfort and energy consumption focus on the role of mechanical systems, not architecture. This paper proposes a new metric, "Thermal Au- tonomy," that links occupant comfort to climate, building fabric, and building operation. Ther- mal Autonomy measures how much of the available ambient energy resources a building can harness rather than how much fuel heating and cooling systems will consume. The change in mental framework can inform a change in process. This paper illustrates how Thermal Auton- omy analysis gives rich visual feedback as to the diurnal and seasonal patterns of thermal com- fort that an architectural proposition is expected to deliver. Thermal Autonomy has far-reaching utility as a comparative metric for envelope design, identifying mechanical strategies, and mixed-mode operation decisions. Foremost, it is a generative metric to quantify ways that the building filters the ambient environment. The use of Thermal Autonomy is illustrated through parametric building thermal simulation and analysis. INTRODUCTION There is a need for the fundamental re-alignment of how we measure and think about thermal comfort in buildings. Most existing metrics were developed to inform the design of mechanical systems. Occasionally, metrics are proposed that define when people are likely to be comforta- ble without heating or cooling systems, but these metrics are framed to avoid energy use rather than embrace the opportunities of climate.
    [Show full text]
  • Thermal Mass Requirement for Building Envelope in Different Climatic Conditions
    Click here for table of contents Click here to search THERMAL MASS REQUIREMENT FOR BUILDING ENVELOPE IN DIFFERENT CLIMATIC CONDITIONS ANIR KUMAR UPADHYAY Architect / Urban Planner 4/24, Park Street, Kogarah NSW 2217, Australia ABSTRACT This study investigates the thermal mass requirement at three different places: Mackay, Brisbane and Amberley in Queensland, Australia. These places have been selected considering their proximity to the nearby coast. Mackay is situated along the coast, Brisbane is located near the coast and Amberley lies inland. Climate data of these cities were retrieved from Bureau of Meteorology’s data bank and climate analysis tools such as Mahoney tables, Building bioclimatic chart were used to get a clear picture of prevailing climatic conditions. Wind roses for different times in different seasons were prepared to understand the wind direction and speed. This paper concludes that provision of thermal mass in buildings is beneficial in coastal as well as inland locations of Queensland. THERMAL MASS IN BUILDING Thermal mass is a major building element in passive solar building design. Passive solar building design understands the local micro-climate and uses natural energies like sun and wind to maintain thermal comfort in buildings. Thermal mass in building fabric will affect the thermal response and performance of spaces. Incorporating thermal mass in buildings helps to balance fluctuating temperatures across the diurnal cycle. A heavy weight building envelope will respond slowly to heat gains from all types of natural or artificial heating sources like sun or mechanical heating systems. Hence, thermal mass assists in the reduction of energy consumed in heating and cooling.
    [Show full text]
  • IRM-G-8721 Nvcdryerbroch
    Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer High Heat Transfer at Work The superior performance of the Nirvana dryer can be attributed to the provides reliability like no other dryer in its class: reliability effective heat transfer capabilities of the exchanger design, utilized that you can count on to protect your air system day in throughout the package for each stage of heat removal. The dryer design includes a pre-cooling system with stainless steel heat exchangers to An innovative corrugated and and day out; reliability built in by design. properly condition the air for drying. A re-heater section of the dryer's folded stainless steel panel is air side also uses these high performance heat exchangers to prepare the stacked inside two stainless steel dried compressed air for re-entry into the air system. This prevents pipe shells, then welded together to form sweating and readies the compressed air for use in process applications. a unitized heat exchanger. This design ensures reliability through the elimination of dissimilar metals or tube in tube chaffing, which is a • common cause for heat exchanger leaks and failures. The Nirvana is a genuine cycling dryer, incorporating innovative features that make it • not only the most reliable, but the most energy efficient, dryer in its class. • The key element central to the Nirvana's 100% stainless steel construction reliability and energy efficiency is its permits optimal heat transfer, distinct, patented heat exchanger design. resulting in a consistent pressure Providing high heat transfer with low dew point.
    [Show full text]
  • Design of Ground Source Heat Pump Systems Thermal Modelling and Evaluation of Boreholes
    THESIS FOR THE DEGREE OF LICENTIATE OF ENGINEERING Design of ground source heat pump systems Thermal modelling and evaluation of boreholes SAQIB JAVED Building Services Engineering Department of Energy and Environment CHALMERS UNIVERSITY OF TECHNOLOGY Göteborg, Sweden 2010 Design of ground source heat pump systems Thermal modelling and evaluation of boreholes Saqib Javed © SAQIB JAVED, 2010 Licentiatuppsats vid Chalmers tekniska högskola Ny serie nr 2706 ISSN 0346-718X Technical report D2010:02 Building Services Engineering Department of Energy and Environment Chalmers University of Technology SE-412 96 GÖTEBORG Sweden Telephone +46 (0)31 772 1000 Printed by Chalmers Reproservice Göteborg 2010 ii Design of ground source heat pump systems Thermal modelling and evaluation of boreholes SAQIB JAVED Building Services Engineering Chalmers University of Technology Abstract Ground source heat pump systems are fast becoming state-of-the-art technology to meet the heating and cooling requirements of the buildings. These systems have high energy efficiency potential which results in environmental and economical advantages. The energy efficiency of the ground source heat pump systems can be further enhanced by optimized design of the borehole system. In this thesis, various aspects of designing a borehole system are studied comprehensively. A detailed literature review, to determine the current status of analytical solutions to model the heat transfer in the borehole system, indicated a shortage of analytical solutions to model the short-term borehole response and the long-term response of the multiple borehole systems. To address the modelling issue of long-term response of multiple boreholes, new methods based on existing analytical solutions are presented.
    [Show full text]
  • Underfloor Heating Guide
    UNDERFLOOR HEATING GUIDE Bringing you the best underfloor heating in South Australia for 30 years. Introduction to Underfloor Heating Due to its supreme level of comfort and great heating efficiency, underfloor heating has become a popular way to heat Australian homes. The feeling of well-being is something we all long for. Feeling warm and comfortable in our homes helps maintain the feeling of well-being and promotes good health. There are numerous ways to experience warmth but only a few that guarantee real comfort. Not only that, hydronic underfloor heating is a worthwhile investment that significantly lower your energy bills. Radiant energy emitted by the floor is partly reflected by each surface and partly absorbed. Where it is absorbed, that surface becomes a secondary emitter. After a while, all surfaces become secondary emitters. Furnishings themselves radiate energy and the room becomes evenly and uniformly warmed. The energy and heat reaches into every corner of the room―no cold spots, no hot ceilings and no cold feet. Sunray has been a leading retailer and installer of hydronic heating systems in South Australia for 3o years. We only use quality components and can assure you of a hydronic system that will provide many years of economical comfort and service. This guide offers information on the different underfloor heating methods and solutions, system components, zone options, combination systems and heat sources available. Say goodbye to dust, ducts and noisy fans. Welcome to the clean, silent world of hydronic heating. sunraycomfort.com.au 2 Underfloor Heating Methods & Solutions Underfloor Heating Before choosing underfloor heating, many Before choosing underfloor heating, factors need to be considered; one of, if not the UnderfloorMethods & Solutions Heating mostBefore important choosing of which,underfloor is floor heating,construction.
    [Show full text]
  • Thermal Mass - Energy Savings Potential in Residential Buildings
    Thermal Mass - Energy Savings Potential in Residential Buildings J. Kosny, T. Petrie, D. Gawin, P. Childs, A Desjarlais, and J.Christian Buildings Technology Center, ORNL ABSTRACT: In certain climates, massive building envelopes-such as masonry, concrete, earth, and insulating concrete forms (ICFs)-can be utilized as one of the simplest ways of reducing building heating and cooling loads. Very often such savings can be achieved in the design stage of the building and on a relatively low-cost basis. Such reductions in building envelope heat losses combined with optimized material configuration and the proper amount of thermal insulation in the building envelope help to reduce the building cooling and heating energy demands and building related CO 2 emission into the atmosphere. Thermal mass effects occur in buildings containing walls, floors, and ceilings made of logs, heavy masonry, and concrete This paper presents a comparative study of the energy performance of light-weight and massive wall systems. An overview of historic and current U.S. field experiments is discussed herein and a theoretical energy performance analysis of a series of wall assemblies for residential buildings is also presented. Potential energy savings are calculated for ten U. S. climates. Presented research work demonstrate that in some U. S. locations, heating and cooling energy demands for buildings containing massive walls of relatively high R-values can be lower than those in similar buildings constructed using lightweight wall technologies. KEY WORDS: DOE-2, whole building energy consumption, heat transfer, thermal resistance, calculation procedure, walls. INTRODUCTION: Several massive building envelope technologies (masonry and concrete systems) are gaining acceptance by U.
    [Show full text]