Article Beehive Air Sampling and Sensing Device Operation in Apicultural Applications—Methodological and Technical Aspects

Andrzej Szczurek and Monika Maciejewska *

Faculty of Environmental Engineering, Wroclaw University of Science and Technology, Wybrzeze˙ Wyspia´nskiego27, 50-370 Wrocław, ; [email protected] * Correspondence: [email protected]; Tel.: 48-71-320-28-68

Abstract: The basis of effective is the information about the state of the colony. A rich source of respective information is beehive air. This source may be explored by applying gas sensing. It allows for classifying bee colony states based on beehive air measurements. In this work, we discussed the essential aspects of beehive air sampling and sensing device operation in apicultural applications. They are the sampling method (diffusive vs. dynamic, temporal aspects), sampling system (sample probe, sampling point selection, sample conditioning unit and sample delivery system) and device operation mode (‘exposure-cleaning’ operation). It was demonstrated how factors associated with the beehive, bee colony and ambient environment define prerequisites for these elements of the measuring instrument. These requirements have to be respected in order to assure high accuracy of measurement and high-quality information. The presented results are primarily based on the field measurement study performed in summer 2020, in three , in   various meteorological conditions. Two exemplars of a prototype gas sensing device were used. These sensor devices were constructed according to our original concept. Citation: Szczurek, A.; Maciejewska, M. Beehive Air Sampling and Sensing Keywords: Device Operation in Apicultural gas sensor; bee; monitoring; indoor air quality; electronic nose Applications—Methodological and Technical Aspects. Sensors 2021, 21, 4019. https://doi.org/10.3390/ s21124019 1. Introduction are critically important for the environment and to the economy [1]. Re- Academic Editor: Giovanna Marrazza cently, the population of these insects has been disappearing at an alarming rate throughout the world. This dangerous phenomenon is still poorly recognized and understood. Prob- Received: 21 May 2021 ably, it is caused by the combined effect of many interrelated, difficult, or impossible to Accepted: 8 June 2021 control factors, e.g., shifting flowering seasons due to climate change, reduced floral diver- Published: 10 June 2021 sity, use of pesticides, habitat loss, lack of genetic diversity, insect parasites and harmful microorganisms [2]. To prevent the losses of bee colonies, populations of these insects have Publisher’s Note: MDPI stays neutral to be maintained in an optimal state of health and afforded opportunities to grow. with regard to jurisdictional claims in Good beekeeping practices need solid, comprehensive information about the state published maps and institutional affil- of colonies, the beehive environment as well as events that may require the iations. ’s action [3]. Traditionally, it comes from observation of honeybee behavior as well as conditions associated with beehives and the environment. This approach may be widely applied; however, it is time consuming and requires great experience. In addition, the obtained information is subjective since it depends on the individual abilities of Copyright: © 2021 by the authors. inspectors or . Licensee MDPI, Basel, Switzerland. The disadvantages of visual inspection mean that monitoring based on instrumental This article is an open access article methods raises great interest in apiculture [4]. This strategy is focused on measurements of distributed under the terms and parameters such as temperature, air humidity, analysis of sound and vibration of a beehive, conditions of the Creative Commons counting outgoing and incoming bees (forager traffic) as well as the number of bees in the Attribution (CC BY) license (https:// hive entrance area, video observation, weighing of the colony, and determination of the creativecommons.org/licenses/by/ 4.0/). content of beehive air [5–9]. The obtained data may provide information about the health,

Sensors 2021, 21, 4019. https://doi.org/10.3390/s21124019 https://www.mdpi.com/journal/sensors Sensors 2021, 21, 4019 2 of 18

productivity, and behavior of honey bees, events and factors influencing the state of bee colony, and physical and chemical conditions inside beehives. Continuous monitoring based on measurements of physical and chemical parameters has been proposed to study colony growth, activity, metabolic processes, genetics, and behavior. In this way, beekeepers can be informed about /pre-swarming state, extreme nectar flow, queenless state, broodless state, dead colony, starving, and first cleaning flight in spring, as well as diseases, including , to evaluate treatment effects. The use of instrumental measuring methods allows to obtain information without invasive hive inspections and disrupting the beehive environment. The aim of this paper is to discuss the selected issues regarding the application of gas sensing devices in beekeeping. We shall focus on beehive air sampling and the operation of the measuring instrument, which is subordinate to the sampling method. Our attention was directed to the impact caused by the environmental factors (beehive and ambient environment) because during gas sensing device operation in field conditions, they significantly affect the measuring process and make it more complicated. Practical aspects and technical limitations are presented. Sharing the observations resulting from the experience acquired during many measurement sessions performed in the field, in different apiaries, owned by different beekeepers and in various ambient conditions, is the principal value of this work. The structure of the paper is as follows. In Section2, the issue of beehive air measure- ments for beekeeping is addressed. We note that the gas sensing application in this domain is promising. Section3 presents the scope of field studies, which have been the source of the most important observations we shared in the paper; the prototype gas sensing device is introduced. Section4 is dedicated to the presentation and discussion of the obtained results. It concentrates on two issues. They are various aspects of: (1) the sampling method and sensing device operation (Section 4.1), and (2) the sampling system itself (Section 4.2). Both are examined in view of performing beehive air measurements in real conditions. Conclusions are presented in Section5.

2. Beehive Air Measurement for Beekeeping It has been noticed that the valuable information for the modern apiculture is associ- ated with the chemical composition of beehive air. The gaseous mixture inside the hive is a unique and complex mixture of many different volatile compounds. These substances are produced and emitted by bees themselves (e.g., pheromones, other chemicals released to repel pests and predators, metabolites, etc.); honey, nectar, larvae, , , and propolis; materials out of which hives are constructed (wood, paint, plastic, etc.) and outside sources, e.g., vehicles, farms, industries, and households in the vicinity of hives. The specific chemical composition of beehive air is essential for the existence of a honey bee colony [10,11]. It creates the odor of the nest, which has the primary and vital func- tion of determining the identity of the colony members. Some volatile compounds drive honeybees’ hygienic behavior. The chemical composition of beehive air reflects sanitary conditions inside the hive and the health condition of the honey bee colony [12]. Today, there are a number of analytical methods and instruments, e.g., infrared analyzers, Fourier-transform infrared spectrometers (FT-IR spectrometers), ion mobility spectrometers (IMS) or gas chromatographs with an appropriate detector (usually FID, tuned mass spectrometer MS or other mass-selective detector), which are capable of detect- ing, identifying, and quantitating the specific chemical species in beehive air [13]. They offer objectivity, good accuracy, sensitivity, and repeatability. However, the cost of such analytical instruments is prohibitive and beyond the reach of the average beekeeper. This equipment is bulky in size, heavy in weight, inconvenient to transport, and its energy consumption is high. The measurement procedure is time-consuming and labor-intensive. Additionally, trained and experienced personnel is required to attain reliable measurement results. Analytical instruments are still mainly dedicated to laboratory works when the speciation is absolutely necessary. Sensors 2021, 21, 4019 3 of 18

The alternative for the conventional equipment, to a certain extent, are measuring instruments based on a sensor technology [14]. They allow to reduce the cost of tests and increase the number of applications in field conditions. Low-cost sensing systems often cost orders of magnitude less than conventional instruments. Sensor devices can be used in modern apiculture for: (1) the identification and quantification of chemical substances that are indicators characterizing the state of the honey bee colony as well as conditions inside beehives, and (2) the classification of beehive air quality [15]. The second variant is more promising. It results from the properties of beehive air indicators. These substances occur in very complex gaseous mixtures. Their concentration is very low, at the level of ppb or ppm. The detection limit of commercial gas sensors usually does not allow to detect these substances. Majority of gas sensors are not selective enough to identify a single chemical species in the gaseous mixture. Additionally, indicators describing honey bee colony states are poorly understood and recognized. Therefore, a holistic approach based on the classification of beehive air quality is frequently proposed and taken into account in the potential applications of an equipment based on gas sensors. Sensing devices, designed for the classification of complex gaseous mixtures, are very often called electronic noses [16]. The working principle of these instruments is inspired by the sensing mechanism of mammal senses. A typical e-nose device includes: a sampling system, an array of chemical gas sensors, a signal conditioning and data acquisition module, and a computer microprocessor with sample classification method (pattern-recognition algorithm). Gas sensors incorporated into the e-nose respond to a wide spectrum of volatile compounds. Hence, the multi-sensor array produces combined output pattern in response to many substances present in the sample mixture. The collective analysis of data originating from the sensor array is the basis for the classification of the tested gas mixtures. The information is obtained by comparing the output from the sensor array to reference databases, produced by the instrument training that is based on mathematical and statistical processes involving pattern recognition algorithms. Classification algorithms use chemometric methods dedicated for processing multivariate data. The electronic nose technology provides effective solutions for the accurate, reliable, and speedy identification of multi-component gas mixtures. It was shown that measuring abilities of the instru- ments based on gas sensors and pattern recognition methods allow to detect varroosis and determine the infestation rate in individual beehives [17,18]. Despite the increasing progress in sensor technology, gas sensing devices of this kind remain largely limited by environmental and technological factors [19–22]. The practical application of these devices is still challenging, and several problems have to be solved. A number of studies have shown that proper gas sampling and operation has a strong influence on the measurement characteristics of the gas sensing device [23,24]. Sampling is one of the most important stages of a measurement process. The sample is the actual source of information about the studied object. Therefore, its proper acquisition is especially important to ensure the information accuracy. If a sample is not collected properly, the whole measurement process is erroneous. Even perfect sensors cannot remove errors generated by faulty sampling. Proper operation of a measurement instrument is essential to ensure that high-quality information is obtained based on the gas sample.

3. Experimental Part 3.1. Gas Sensing Device The gas sensing devices used in our work were direct reading instruments. They provide single values of responses per sensor, at a given point in time, that allow to classify different complex gas mixtures. These devices were developed in the Laboratory of Sensor Technique and Indoor Air Quality Studies, WUST. The instruments were dedicated not only for professionals. They were easy to use and worked with the minimal operator attention. The measurement process was automated. They allowed to perform both short- and long- term measurements. The data was provided in real time. The embedded GSM-module allowed for the remote internet connection and the collection of the measurement results. Sensors 2021, 21, x FOR PEER REVIEW 4 of 19

only for professionals. They were easy to use and worked with the minimal operator at- Sensors 2021, 21, 4019 4 of 18 tention. The measurement process was automated. They allowed to perform both short- and long-term measurements. The data was provided in real time. The embedded GSM- module allowed for the remote internet connection and the collection of the measurement Theresults. construction The construction of these of devices these devices made themmade well-suitedthem well-suited to work to work in field in conditions.field condi- Thetions. sensing The sensing devices devices were were simple simple to deploy to deploy in apiaries in apiaries in in remote remote localizations. localizations.They They allowedallowed toto performperform onlineonline measurements,measurements, directly directly at at thethe beehives.beehives. ThereThere waswas notnot requiredrequired samplesample transporttransport toto thethe laboratorylaboratory oror itsits specialspecial handlinghandling toto avoidavoid deteriorationdeterioration ofof thethe collectedcollected gas.gas. TheThe seriousserious limitationlimitation ofof thethe devicesdevices waswas highhigh energy energy consumption. consumption. TheThe powerpower consumptionconsumption of the measurement device device should should not not exceed exceed 40 40 W W and and typically typically it itis isaround around 10 10 W W (without (without heated heated gas gas line). line). Sensor Sensor heaters heaters consume consume around around 3 W. 3 The W. Thetem- temperatureperature control control of ofthe the sensor sensor chamber chamber requires requires about about 3 3 W. W. TheThe electronicselectronics consumeconsume aroundaround 11 to 1.3 W. W. Data Data transmission transmission requires requires less less than than 1 1W. W. The The pump pump needs needs about about 1.7 1.7W. W.The The heated heated gas gas line line consumes consumes 7 W. 7 W.In order In order to assure to assure 10 h 10 of h continuous of continuous operation, operation, we weused used high high amp-hour amp-hour batteries batteries REC22-12-(Capacity REC22-12-(Capacity 22Ah 22Ah @ 20hr-rate, @ 20hr-rate, Voltage Voltage 12V) which 12 V) whichwere heavy were heavy(weight (weight approximately approximately 6.2 kg) 6.2and kg) expensive. and expensive. Independent Independent power sources, power sources,such as solar such panels, as solar offered panels, an offered opportunity an opportunity to work in to localizations, work in localizations, where the where electrical the electricalsupply network supply was network not available. was not However, available. b However,eekeepers beekeepersdid not accept did this not solution. accept thisThe solution.gas sensing The devices gas sensing developed devices in developedour lab can in be our used lab as can portable be used as as well portable as stationary as well asinstruments. stationary instruments.Currently, a handheld Currently, version a handheld is not version yet available. is not yet However, available. compared However, to comparedtraditionalto analytical traditional instruments analytical based instruments on gas analysis based on methods, gas analysis such methods,as gas chromatog- such as gasraphy chromatography mass spectrometry mass (GC-MS) spectrometry and Fourier (GC-MS) transform and Fourier infrared transform (FT-IR) infrared spectrometry, (FT-IR) spectrometry,gas sensor devices gas sensor have devices the potential have the to potentialbe small, to compact, be small, fast, compact, inexpensive fast, inexpensive and cost- andeffective cost-effective in operation. in operation. TheThe gasgas sensingsensing devicedevice whichwhich waswas usedused inin ourour experimentsexperiments isis shownshown inin FigureFigure1 .1. It It consistedconsisted ofof thethe followingfollowing parts:parts: • gas sampling unit with sample delivery system; • gas sampling unit with sample delivery system; • array of six low-cost semiconductor gas sensors (TGS822, TGS823, TGS826, TGS2600, • array of six low-cost semiconductor gas sensors (TGS822, TGS823, TGS826, TGS2600, TGS2602, TGS2603) with partial or overlapping sensitivities; TGS2602, TGS2603) with partial or overlapping sensitivities; • circuit for an analog signal conditioning; • circuit for an analog signal conditioning; • module for data acquisition, and storage; • module for data acquisition, and storage; • signal preprocessing module; • signal preprocessing module; • pattern recognition machine; • pattern recognition machine; • GSM module for data transmission; • GSM module for data transmission; • GPS module for instrument localization. • GPS module for instrument localization.

FigureFigure 1.1. GasGas sensingsensing devicedevice whichwhich waswas usedused inin ourour experiments.experiments.

AsAs shownshown in Figure 11,, thethe gasgas sensing device is is portable portable and and protected protected by by two two inde- in- dependentpendent waterproof waterproof cases. cases. The The top top case case hosts hosts the themeasuring measuring instrument. instrument. The Thebottom bottom case case contains batteries. There is a cable connection between the two parts. The device is fitted with two gas inlets: ambient air inlet for regeneration gas preparation (first from the top), gas sample inlet (second from the top) and gas outlet. Keypad allows for the Sensors 2021, 21, 4019 5 of 18

direct communication with the instrument. Signaling diodes provide the information about its status. The major element of the measurement device was the gas sensor array. It was com- posed of commercially available semiconductor gas sensors, which are offered by Figaro Engineering, Osaka, Japan [25]. We chose the following ones: TGS822, TGS823, TGS826, TGS2600, TGS2602 and TGS2603. According to the producer, for sensors included in the array, the target gases are as follows: TGS822—organic solvent vapors, TGS823—organic solvent vapors, TGS826—ammonia, TGS2600—air contaminants (high sensitivity to hy- drogen and carbon monoxide), TGS2602—air contaminants (high sensitivity to odorous gases such as ammonia and H2S) and TGS2603—air contaminants (high sensitivity to odorous gases such as amine-series and causing sulphurous odour). However, the indi- vidual semiconductor gas sensors are sensitive to multiple volatile compounds and their sensitivity ranges are partially overlapping. On purpose, sensors applied in our device had different detection ranges. In particular, the detection range of sensors TGS2600, TGS2602 and TGS2603 is from 1 ppm to several dozen ppm. The detection ranges of sensors TGS822, TGS823 and TGS826 are from 10 ppm to more than 1000 ppm. The selection of sensors was based on the assumption that: (1) we should concentrate on volatile organic compounds as the source of information about bee colony, (2) the composition of beehive air is complex, largely unknown, and highly variable. The gas sensor signal was defined as the voltage across the voltage divider, which consists of the chemosensing element and the load resistor. The method to convert the sensor resistance RS to the recorded signal, VRL, is given by Equation (1).

VRL = VC RL/ (RL + RS) (1)

where: VC is the circuit voltage equal to 3.3 V, RL is the value of the load resistor equal to 10 kΩ for TGS sensors series 800 and 2 kΩ for TGS sensors series 2000. This paper is focused on the first element of the gas sensing instrument, which is the gas sampling and sample delivery system and the device operation mode. Two exemplars of the gas sensing device were used for testing these elements of the equipment in real field conditions.

3.2. Apiaries The presented results are primarily based on field studies. The field studies were performed in July, August, and September 2020. The measurements were carried out in three professional, private apiaries, located in southwestern Poland, in dolno´sl˛askie and opolskie voivodships. Two apiaries were located on the border between forests and fields. One was located in the garden. We encountered various kinds of beehives in the apiaries. They are displayed in Figure2. The majority of beehives were wooden ones. They were built by beekeepers themselves. The beehives were the modified versions of some standard constructions, or they were beekeepers’ own constructions. The adjustment of well-established constructions to the local, specific needs is a common situation among Polish beekeepers. The measurements were performed during the daytime, in various meteorological conditions. The weather was mild or hot with temperatures ranging from 20 ◦C to above 30 ◦C in the middle of the day. Most days were sunny. Single days were cloudy. Rainy weather was encountered only once. Sensors 2021, 21, 4019 6 of 18 Sensors 2021, 21, x FOR PEER REVIEW 6 of 19

(a) (b)

(c)

Figure 2. Different kindskinds ofof beehives,beehives, whichwhich werewere included included in in the the study. study. They They were were wooden. wooden. They They were were built built by by beekeepers. beekeep- (ers.a) Apiary (a) Apiary 1 located 1 located on the on borderthe border between between forest forest and and field, field, (b) Apiary(b) Apiary 2 located 2 located in the in garden,the garden, (c) Apiary (c) Apiary 3 located 3 located on the on borderthe border between between forest forest and and field. field.

The measurements were performed during the daytime, in various meteorological 4. Results and Discussion conditions. The weather was mild or hot with temperatures ranging from 20 °C to above 30 °CIn in our the study, middle gas of samplingthe day. Most was thedays operation were sunny. of removing Single days a part were of beehivecloudy. airRainy (of weatherproper volume) was encountered from the wholeonly once. beehive in such a manner that the sample represented, within measurable limits of error, the chemical composition of this gas. The objective of 4.sampling Results wasand toDiscussion ensure that the sampled gas was representative. The representative gas sample has the same characteristics as beehive air at the sampling point and time. In our study, gas sampling was the operation of removing a part of beehive air (of Our studies have shown that several issues have to be taken into account in the proper volume) from the whole beehive in such a manner that the sample represented, development of the beehive air sampling method and equipment. The most important are: withinproperties measurable of beehive limits air, environmentalof error, the chemical conditions, composition honey bee of behavior, this gas. constructionThe objective and of samplingmaterials ofwas sampling to ensure equipment, that the sampled and characteristics gas was representative. of gas sensors. The Other representative factors such gas as sampleconvenience, has the site same accessibility, characteristics technical as beehive limitations air at and the costssampling also playpoint an and important time. role in developingOur studies the have sampling shown strategy. that several In all issues test situations, have to be consideration taken into account must be in given the de- to: velopmentfluctuations of of the pressure, beehive temperature, air sampling or method concentration and equipment. of beehive The air most components important due are: to propertiesuncontrollable of beehive variations air, environmental in the beehive cond and outdooritions, honey environment bee behavior, moisture construction content and materialsexpected interferences.of sampling equipment, and characteristics of gas sensors. Other factors such as convenience, site accessibility, technical limitations and costs also play an important role in4.1. developing Sampling Method the sampling and Device strategy. Operation In all test situations, consideration must be given to: fluctuations4.1.1. Diffusive of pressu Samplingre, temperature, or concentration of beehive air components due to uncontrollableOnline measurements variations in ofthe beehive beehive air an cand outdoor be performed environment using moisture diffusive content or dynamic and expectedmethods interferences. of gas sampling. The operating principle of the diffusive sampling relies on the movement of a sample due to the concentration gradient established between the tested gas and a sensor. The gas is taken from the beehive at a rate controlled only by a

Sensors 2021, 21, 4019 7 of 18

physical process such as diffusion through a static air layer or a porous material and/or permeation through a membrane. The gas transport is described by Fick’s First Law. Main advantages of the diffusive sampling are cost effectiveness and simplicity. This method is especially attractive when limitations in dimension and energy consumption are the critical factors. The diffusive sampling does not require a power supply since the active movement of beehive air through the sensor device is not involved. Natural air currents deliver gas sample to sensors. As a pump or fan is not applied to move the gas, the sampling process is completely quiet. This is an important advantage in applications in which the measuring device has to be located inside the beehive. Diffusive sampling also has serious disadvantages. The performance of this method is dependent on the diffusion coefficient, which is affected by the unique chemical and physical properties of gas under test, construction of the sensor housing (its geometry and shape) as well as by a number of environmental factors. Sensor devices based on gas diffusion have to deal with fluctuations of environmental conditions. The dependence of the diffusion coefficient on temperature and pressure significantly reduces the sampling rate when stagnant conditions occur. It is a strong limitation if the measuring system presents the memory effects. The relatively slow gas exchange in diffusive sampling causes the responses of the sensors to be slower. It may be problematic and undesirable in some applications. In our work, we gave preference to dynamic sampling.

4.1.2. Dynamic Sampling Due to the conditions inside a beehive, a measurement device should be located outside the beehive. The consequence of such a choice is that the dynamic sampling must be involved in the measurement process. In this method, the representative portion of the tested gas is continuously withdrawn from the sampling point and transported, at a controlled flowrate, to the sensor chamber for real-time measurements. The movement of the sample is activated by a pump. The dynamic sampling ensures continuous and constant gas flow across the measurement unit. Dynamic sampling is especially valuable for assessing a temporal variability of beehive air properties. Usually, this gas is highly heterogeneous and its content changes dynamically in time.

4.1.3. Continuous Sampling Theoretically, continuous sampling coupled with sensor measurements may rapidly provide data regarding changes in a beehive environment. In practice, there are some constraints in the application of this strategy. The shortcomings result, e.g., from the properties of gas sensors—especially chemiresistors. Many of these devices present a drift, memory effect and a tendency to become saturated under the influence of some organic compounds. It leads to poor reversibility and reproducibility of the sensor responses and is reflected in a false interpretation of the measurement results. Among the most serious limitation of many gas sensors is the “long-term” drift problem. It may be identified and characterized by significant temporal variations of sensor signals, changes in the sensing material baseline and measurement sensitivity over time. Sensors with “long-term” drift do not give stable responses over a long period of time, even when they are exposed to identical gas mixtures. Saturation of the sensing material, long term drift, as well as the memory effect originate from numerous, sometimes unrecognized processes, e.g., aging, contamination or poisoning of a sensing material. It is difficult to eliminate causes of these processes. The appropriate operation of sensor device allows to reduce these disadvantages.

4.1.4. ‘Exposure-Cleaning’ Operation The hybrid method, which is a combination of exposure and cleaning operations, may be a good alternative for continuous sampling. In such an approach, the portion of the tested gas is taken and transferred to the sensor chamber in a periodic manner. The gas sampling and exposure are performed simultaneously. The exposure of each sensor to the test gas is followed by a cleaning phase, which is aimed to restore the sensor Sensors 2021, 21, x FOR PEER REVIEW 8 of 19

processes. The appropriate operation of sensor device allows to reduce these disad- vantages.

4.1.4. ‘Exposure-Cleaning’ Operation The hybrid method, which is a combination of exposure and cleaning operations, Sensors 2021, 21, 4019 may be a good alternative for continuous sampling. In such an approach, the portion8 of 18of the tested gas is taken and transferred to the sensor chamber in a periodic manner. The gas sampling and exposure are performed simultaneously. The exposure of each sensor to the test gas is followed by a cleaning phase, which is aimed to restore the sensor char- characteristics.acteristics. This This operation operation is carried is carried out outby means by means of a ofstream a stream of a of reference a reference gas. gas. In our In ourconstruction, construction, this thisgas gaswas wasdry dryair, air,purified purified by a by simple a simple filtering filtering of atmospheric of atmospheric air. The air. Thefilter filter consisted consisted of an of activated an activated charcoal. charcoal. The re Thespective respective part of part the of reference the reference gas line, gas inside line, insidethe gas the sensor gas sensor device, device, is shown is shown in Figure in Figure 3. The3 Teflon. The Teflon filter and filter the and charcoal the charcoal filter, filter,which whichwere mounted were mounted on the on gas the line gas used line used for deliv for deliveringering the cleaned the cleaned ambient ambient air airfor forsensors sensors re- regeneration,generation, are are displayed. displayed. Filt Filtrationration was was used used to to reduce and stabilizestabilize thethe concentrationsconcentrations ofof organicorganic compoundscompounds in in the the ambientambient air, air, which which was was delivered delivered to to the the sensor sensor system. system. Based Based onon ourour calculations,calculations, thethe charcoalcharcoal filterfilter waswas sufficientsufficient toto performperform measurementsmeasurements forfor thethe wholewhole season,season, i.e.,i.e., forfor sixsix months months of of continuous continuous measurements. measurements.

FigureFigure 3.3. The interior interior of of gas gas sensing sensing device. device. Top—the Top—the ga gass line line used used for fordelivering delivering the thecleaned cleaned am- bient air for sensors regeneration; Teflon filter and charcoal filter were mounted on this line. Bottom ambient air for sensors regeneration; Teflon filter and charcoal filter were mounted on this line. —the gas line used for delivering gas sample; only Teflon filter was mounted on this line. Bottom —the gas line used for delivering gas sample; only Teflon filter was mounted on this line.

TimeTime requiredrequired for for performing performing thethe ‘exposure-cleaning‘exposure-cleaning’’ operation operation is is an an important important factor factor influencinginfluencing the the application application potential potential of of gas gas sensing sensing devices. devices. In our In our work, work, the sampling the sampling and exposureand exposure time wastime 5was min. 5 min. It was It determinedwas determin oned the on basis the basis of the of beehive the beehive air measurement air measure- datament analysis data analysis as the totalas the amount total amount of time sufficientof time sufficient to reach 90%to reach of the 90% saturation of the saturation value by thevalue measurement by the measurement signals, see signals, Figure see4a. Figure In general, 4a. In the general, full stabilization the full stabilization of the semicon- of the ductorsemiconductor gas sensors gas insensors beehive in airbeehive measurements air measurements cannot be cannot expected be expected since these since devices these seldomdevices reach seldom an equilibriumreach an equilibrium state with state volatile with organic volatile compounds organic compounds (VOCs) in a(VOCs) short time. in a Usually,short time. the Usually, response the time response of gas sensors time of ranges gas sensors from seconds ranges from up to seconds several minutes.up to several It is causedminutes. by It slow is caused dynamics by slow of the dynamics sensing material. of the sensing Moreover, material. rapid Moreover, fluctuations rapid of the fluctua- tested gastions composition, of the tested or gas variation composition, of its access or variat to theion sample of its access probe areto the oftentimes sample encounteredprobe are of- intentimes beehive encountered air measurements, in beehive see Figureair measurements,4b. see Figure 4b. The duration of the cleaning phase results from the time required for achieving full regeneration of the sensing material. In our device, this value was set at the level of 5 min. Based on multiple measurements, this time was sufficient to attain the repeatable level of regeneration of the sensing material, although the regeneration was not always complete. This fact is illustrated in Figure4, by the sensor baseline shift upon subsequent regenerations as compared with the first exposure to clean air. In general, the required recovery time may be longer than the response time. Oftentimes, it is the factor which limits achieving high measurement frequencies for continuous monitoring applications. Dynamic sampling prevents changes of gas sample composition before it reaches the sensor chamber. The method based on ‘exposure–cleaning’ operation ensures the rapid transfer and exchange of gas inside the measurement chamber as well as fast regeneration of sensors. However, a high sampling rate can change the beehive air composition around a sampling probe. It is due to natural ventilation of the beehive. For that reason, the amount of air taken from a beehive should be relatively small, although sufficient to obtain a representative sample. This poses a requirement on the flow rate of the sampled gas. In our system, the gas flow rate was set at the level of 1 L/min. It was not observed that this flow rate applied for a five-minute sampling period caused a measurable change of the signal resulting from the dilution of beehive air in the surrounding of the sampling point. This conclusion was inferred from the observation that sensor signals recorded during Sensors 2021, 21, x FOR PEER REVIEW 9 of 19

(a) (b) Figure 4. Raw sensor signals resulting from ‘exposure-cleaning’ operation repeated four times, pre- ceded by the establishment of the initial baseline; (a) signals of most sensor approach the steady state during exposure to beehive air; (b) sensor signals do not attain steady state due to rapid fluc- tuations of the tested gas composition or obstruction of its access to sample probe. Dotted lines show Sensors 2021, 21, 4019 9 of 18 the baseline of the first sensor signal as indicated by the initial exposure to clean air.

The duration of the cleaning phase results from the time required for achieving full

Sensors 2021, 21, x FOR PEER REVIEWregeneration multiplesubsequent of the sensing ‘exposure-cleaning material. In our’ operations device, this were value not was systematically set at the level decreasing, of 5 min.9 of 19 see BasedFigure on multiple5, unless measurements, due to changes this of beehive time was atmosphere sufficient causedto attain by the bee repeatable colony activity level of e.g., regenerationits diurnal of cycle, the sensing see Figure material,6c,d. although the regeneration was not always complete. This fact is illustrated in Figure 4, by the sensor baseline shift upon subsequent regenera- tions as compared with the first exposure to clean air. In general, the required recovery time may be longer than the response time. Oftentimes, it is the factor which limits achiev- ing high measurement frequencies for continuous monitoring applications. Dynamic sampling prevents changes of gas sample composition before it reaches the sensor chamber. The method based on ‘exposure–cleaning’ operation ensures the rapid transfer and exchange of gas inside the measurement chamber as well as fast regeneration of sensors. However, a high sampling rate can change the beehive air composition around a sampling probe. It is due to natural ventilation of the beehive. For that reason, the amount of air taken from a beehive should be relatively small, although sufficient to ob- tain a representative sample. This poses a requirement on the flow rate of the sampled gas. In our system, the gas flow rate was set at the level of 1 L/min. It was not observed that this flow rate applied(a) for a five-minute sampling period caused(b a) measurable change of the signal resulting from the dilution of beehive air in the surrounding of the sampling point.FigureFigure This 4. 4.Raw conclusionRaw sensor sensor signals was signals inferred resulting resulting from from from the ‘exposure-cleaning ‘observationexposure-cleaning that’ operation’ operationsensor repeatedsignals repeated recorded four four times, times, dur- pre- pre- ceded by the establishment of the initial baseline; (a) signals of most sensor approach the steady ing cededmultiple by the subsequent establishment ‘exposure-cleaning of the initial baseline;’ operations (a) signals were of mostnot systematically sensor approach decreasing, the steady state state during exposure to beehive air; (b) sensor signals do not attain steady state due to rapid fluc- during exposure to beehive air; (b) sensor signals do not attain steady state due to rapid fluctuations seetuations Figure of 5,the unless tested duegas composition to changes or of obstruction beehive atmosphere of its access tocaused sample by probe. bee Dottedcolony lines activity show of the tested gas composition or obstruction of its access to sample probe. Dotted lines show the e.g.,the itsbaseline diurnal of the cycle, first see sensor Figure signal 6c,d. as indicated by the initial exposure to clean air. baseline of the first sensor signal as indicated by the initial exposure to clean air. The duration of the cleaning phase results from the time required for achieving full regeneration of the sensing material. In our device, this value was set at the level of 5 min. Based on multiple measurements, this time was sufficient to attain the repeatable level of regeneration of the sensing material, although the regeneration was not always complete. This fact is illustrated in Figure 4, by the sensor baseline shift upon subsequent regenera- tions as compared with the first exposure to clean air. In general, the required recovery time may be longer than the response time. Oftentimes, it is the factor which limits achiev- ing high measurement frequencies for continuous monitoring applications. Dynamic sampling prevents changes of gas sample composition before it reaches the Sensors 2021, 21, x FOR PEER REVIEW sensor chamber. The method based on ‘exposure–cleaning’ 10operation of 19 ensures the rapid

transfer and exchange of gas inside the measurement chamber as well as fast regeneration of sensors. However, a high sampling rate can change the beehive air composition around (a) (b) a sampling probe. It is due to natural ventilation of the beehive. For that reason, the amount of air taken from a beehive should be relatively small, although sufficient to ob- tain a representative sample. This poses a requirement on the flow rate of the sampled

gas. In our system, the gas flow rate was set at the level of 1 L/min. It was not observed that this flow rate applied for a five-minute sampling period caused a measurable change of the signal resulting from the dilution of beehive air in the surrounding of the sampling point. This conclusion was inferred from the observation that sensor signals recorded dur- ing multiple subsequent ‘exposure-cleaning’ operations were not systematically decreasing, see Figure 5, unless due to changes of beehive atmosphere caused by bee colony activity e.g., its diurnal cycle, see Figure 6c,d.

(c)

Figure 5. Results of bee colonyFigure monitoring 5. Results using of bee ‘exposure-cleaning colony monitoring’ operation. using ‘exposure-cleaning On the measurement’ operation. On the measurement day, the beehive air did notday, display the beehiveany pattern air did of temporal not display variation, any pattern which of could temporal be associated variation, which could be associated with the measurement system operation. In particular, sensor signals did not decrease regularly in with the measurement system operation. In particular, sensor signals did not decrease regularly in time; (a) raw sensor signals, (b) baseline for subsequent ‘exposure-cleaning’ operations, and (c) sensor time; (a) raw sensor signals, (b) baseline for subsequent ‘exposure-cleaning’ operations, and (c) sensor signals after differential baseline correction. signals after differential baseline correction.

(a) (b)

(a) (b)

(c) (d) Figure 6. Results of monitoring two bee colonies, living in one apiary, in adjacent beehives during two consecutive days. (a) Bee colony 1 on day 1; (b) bee colony 1 on day 2; (c) bee colony 2 on day 1; (d) bee colony 2 on day 2.

In the designed sensor system, cleaned ambient air was not only used for sensor re- generation and cleaning of the measuring system; it was also the reference gas. The signal measured at the end of the cleaning phase was settled as the baseline value, VRL0, and it was used as the reference for the subsequent exposure to the gas sample. It was assumed that the useful response of sensor array (Figure 5c) to the tested gas should be the differ- ence between the signal measured during the exposure VRL (Figure 5a) and the baseline VRL0 (Figure 5b). From the baseline behavior during the day (Figure 5b), it may be noticed

Sensors 2021, 21, x FOR PEER REVIEW 10 of 19

(c) Figure 5. Results of bee colony monitoring using ‘exposure-cleaning’ operation. On the measurement day, the beehive air did not display any pattern of temporal variation, which could be associated with the measurement system operation. In particular, sensor signals did not decrease regularly in Sensors 2021, 21, 4019 time; (a) raw sensor signals, (b) baseline for subsequent ‘exposure-cleaning’ operations, and (c) sensor10 of18 signals after differential baseline correction.

(a) (b)

(c) (d)

FigureFigure 6. 6.ResultsResults of ofmonitoring monitoring two two bee bee co colonies,lonies, living living in inone one apiary, apiary, in in adjacent adjacent beehives beehives during during twotwo consecutive consecutive days. days. (a ()a Bee) Bee colony colony 1 1on on day day 1; 1; (b (b) )bee bee colony colony 1 1 on on day day 2; 2; ( (cc)) bee bee colony colony 2 on day 1; 1; (d) bee colony 2 on day 2. (d) bee colony 2 on day 2.

InIn the the designed designed sensor sensor system, system, cleaned cleaned ambient ambient air was air wasnot only not only used used for sensor for sensor re- generationregeneration and andcleaning cleaning of the of measuring the measuring system system;; it was italso was the also reference the reference gas. The gas. signal The measured at the end of the cleaning phase was settled as the baseline value, VRL0, and it signal measured at the end of the cleaning phase was settled as the baseline value, VRL0, wasand used it was as the used reference as the referencefor the subsequent for the subsequent exposure to exposure the gas tosample. the gas It sample.was assumed It was thatassumed the useful that response the useful of responsesensor array of sensor (Figure array 5c) to (Figure the tested5c) to gas the should tested be gas the should differ- be encethe between difference the between signal measured the signal during measured the duringexposure the V exposureRL (Figure V RL5a)(Figure and the5a) baseline and the VRL0baseline (Figure V RL05b).(Figure From the5b). baseline From the behavior baseline duri behaviorng the during day (Figure the day 5b), (Figure it may5b), be it noticed may be noticed that sensor regeneration process was effective. Hence, the information collected during a particular exposure was not biased by the previous exposure. Based on the experimental data, measurement results obtained from a single ‘exposure- cleaning’ operation do not provide accurate information about beehive air. Data analysis has shown that valuable information was obtained if a measurement session consisted of at least four consecutively performed ‘exposure-cleaning’ operations, see Figure4. In other words, measurement sessions should consist of a minimum of four tests. The monitoring program of beehive air may be based on one or many separate measurement sessions, performed in different time periods; see, e.g., Figures5 and6.

4.1.5. Consideration of Temporal Factors Influencing Operation of Gas Sensing Devices in Beekeeping The gas sample should be representative in terms of any temporal variations associated with the monitored process. Hence, ‘exposure-cleaning’ operation may have to be performed many times at different time points. The duration of the individual measurement sessions, their number, and the period of time when they are performed depends on the purpose of the monitoring program, the temporal variations of factors influencing beehive air, and also on technical conditions. The selection of the appropriate time for measurements has a Sensors 2021, 21, 4019 11 of 18

principal significance for the realization of beehive monitoring. There is a high probability of obtaining misleading information when the measuring session is performed in an inadequate time period. This problem is mainly associated with the temporal variability of beehive air [26]. The chemical composition of air inside the beehive presents a temporal variability, see Figure6. It is caused by internal factors, but it is also influenced by the outdoor environment. The concentration of VOCs in the beehive air and their variation in time may be influenced by the outdoor level of these substances. There are many sources of VOCs in the environment, both biotic and abiotic, with the time-dependent emission, which may affect the air inside the beehive. The variability of this gas results also from the changing weather conditions, especially fluctuations of atmospheric temperature, pressure, and humidity as well as rain and wind. Internal factors include the activity and behavior of honey bees, e.g., changes in foraging activity. Each of those temporal disturbances induces specific variation of sensor signals. Figure6 presents the results of monitoring of two bee colonies, for one colony in Figure6a,b, and for the second colony in Figure6c,d. They inhabited the adjacent beehives of the same kind, in one apiary. Measurements were carried out on two days. The results collected on day I are shown in Figure6a,c and the results collected on day II are shown in Figure6b,d. Clearly, the air in the beehives of two bee colonies displayed different characteristics and temporal variability patterns, although the ambient conditions in the monitoring period were the same. The factors associated with the colony itself dominated the information contained in gas sensing device readings. It should be underlined that the observed temporal variation of sensor signals contains relevant pieces of information, and it should not be confused with noise, which is random and erratic. The changes of beehive air very often present specific patterns of occurrence. The most obvious cycles of variation are seasonal and diurnal. The seasonal cycle is associated with the meteorological conditions which exhibit quite a predictable annual pattern of changes. The diurnal cycle of variation is mostly caused by a daily pattern of bee activity. As beehive air characteristics may vary in different time scales, the selection of the appropriate time for measurements and the duration of the measurement session is a particularly important issue. In other words, there has to be a chosen number of ‘exposure-cleaning’ operations that should be carried out. If the level of temporal variability of beehive air is high, a larger number of ‘exposure-cleaning’ operations need to be performed. Many ‘exposure-cleaning’ operations give a chance to obtain the results, with better precision and accuracy. However, long measurement sessions require time and resources. The universal solution of this problem is unknown. Only the detailed observation of the environmental factors and understanding of honey bee colony biology can give a clue to whether the duration of measurement session is sufficient to obtain the appropriate data. The important issue is also the time of the day when the measuring sessions should be performed. It was demonstrated that the adequate time of sampling and measurements allows to obtain better effectiveness of bee disease detection [26]. This knowledge is important from an economical point of view because it helps in planning an effective sampling program for the whole apiary.

4.2. Sampling System The dynamic sampling is performed by a suitable pneumatic system. In this work, the role of the sampling system was to withdraw the representative portion of beehive air and convey it to the sensor chamber. Our sampling system was easily adaptable to different field conditions thanks to modular construction. It consisted of a sample probe, filtration unit and the sample delivery system. The construction of a sampling system is largely dependent on the type of gas to be tested. Physical adsorption on solid surfaces, chemical activity and stability of various beehive air components are different. Therefore, materials used for the sampling operations and construction of the sampling equipment Sensors 2021, 21, 4019 12 of 18

that come into contact with the beehive air must be such that they do not significantly affect the composition of gas sample.

4.2.1. Sample Probe The insertion of a sample probe in the hive should be to a maximum non-intrusive, in order to avoid modifying the bees’ environment. In addition, the sampling procedure and the probe material cannot change the chemical composition of a gas sample. Two types of sampling probes were tested in our studies. These probes are shown in Figure7. The first one was prepared in advance by a 3D printing technique. The first kind of probe was very convenient, provided that the probe could be located between combs and placed there by accessing the beehive from the top. There was not an observed probe interference with comb maintenance by the bees. The second probe was invented in the apiary, in response to the urgent need. We found that a beekeeper may not agree to disturb bees by opening the beehive for probe installation. In such a case, the air has to be sampled via the exit of the hive. However, in a moderate climate, late summer, beehive exits are narrowed to prevent robbing by pests, e.g., mice. Gas sampling through the beehive exit requires that the sample probe has a small diameter, it is relatively stiff (not to move around the bottom of the beehive) and allows for collecting air over a certain distance, rather than from nearly one point. This is because one does not see the actual location of the probe when accessing the beehive this way. This goal was largely attained by the second kind of probe. It was made by cutting the gas line (PE) with small cuts, close to its end, at the distance of about 10 cm. We did not notice that the construction of the probe was reflected in the measured sensor signals, i.e., readily changed their character. However, it should Sensors 2021, 21, x FOR PEER REVIEWbe mentioned that bees tend to cover foreign objects inside the hive with propolis or13 wax,of 19

which would interfere with the beehive air access to the sampling probe and its movement across the probe. So, this element must be checked with some regularity to ensure that it is sufficiently clean. The first construction was more prone to clogging.

(a) (b)

FigureFigure 7. 7. SampleSample probes probes used used in in our our studies: studies: ( (aa)) probe probe made made in in advance advance by by 3D 3D printing; printing; the the thickness thickness ofof the the probe is greater than thethe gas line diameter (6/4 mm); mm); ( (bb)) probe probe invented invented and and made made in in field field conditions. The gas line was cut with small holes, close to its end. The probe has the diameter of the conditions. The gas line was cut with small holes, close to its end. The probe has the diameter of the gas line. gas line. 4.2.2.4.2.2. Sampling Sampling Point Point Selection Selection TheThe sampling probeprobe locationlocation in in the the measured measured object object is is of of the the utmost utmost importance importance for thefor themeasurement measurement process. process. In a In closed a closed system, system where, where the gasthe gas composition composition is homogeneous is homogeneous and andunchanged, unchanged, samples samples may may be taken be taken anywhere anywhere within within the object.the object. However, However, the composition the compo- sitionof beehive of beehive air varies air withinvaries awithin beehive a beehive [27]. Hence, [27]. theHence, selection the selection of an appropriate of an appropriate sampling samplingsite was of site paramount was of paramount importance importance in our study. in The our spatial study. variability The spatial of variability beehive air of results bee- hivefrom air the results construction from the of construction a beehive, behavior of a beehive, of honey behavior bee colony of honey and thebee influencecolony and of the influenceoutdoor environment. of the outdoor Additionally, environment. the Additi constructiononally, of the the construction beehive as well of the as thebeehive attitude as wellof the as beekeeperthe attitude has of athe strong beekeeper influence has a on stro theng possibility influence on to installthe possibility the sample to install probe the in samplea particular probe location, in a particular for example, location, between for example, combs, between see Figure combs,8a, or see at Figure the bottom 8a, or of at thethe bottombeehive, of see the Figure beehive,8b. see Figure 8b.

(a) (b) Figure 8. Different location of the sampling point inside the beehive: (a) between combs and (b) under combs, at the bottom of the beehive.

Based on our measurements, the differences among sensor responses to gas sampled at various points within a hive could be large. For example, the placement of the probe near the beehive exit usually resulted in strongly fluctuating sensor signals. The exem- plary measurement results collected in such circumstances are shown in Figure 9b. Con- trarily, when the air was sampled from the space between the combs, sensor signals dis- played less variability. The respective example of measurement results is shown in Figure 9a.

Sensors 2021, 21, x FOR PEER REVIEW 13 of 19

(a) (b) Figure 7. Sample probes used in our studies: (a) probe made in advance by 3D printing; the thickness of the probe is greater than the gas line diameter (6/4 mm); (b) probe invented and made in field conditions. The gas line was cut with small holes, close to its end. The probe has the diameter of the gas line.

4.2.2. Sampling Point Selection The sampling probe location in the measured object is of the utmost importance for the measurement process. In a closed system, where the gas composition is homogeneous and unchanged, samples may be taken anywhere within the object. However, the compo- sition of beehive air varies within a beehive [27]. Hence, the selection of an appropriate sampling site was of paramount importance in our study. The spatial variability of bee- hive air results from the construction of a beehive, behavior of honey bee colony and the influence of the outdoor environment. Additionally, the construction of the beehive as Sensors 2021, 21, 4019 well as the attitude of the beekeeper has a strong influence on the possibility to install13 ofthe 18 sample probe in a particular location, for example, between combs, see Figure 8a, or at the bottom of the beehive, see Figure 8b.

(a) (b)

Figure 8. Different location ofFigure the sampling 8. Different point location inside theof the beehive: sampling (a) between point inside combs the and beehive: (b) under (a combs,) between at the combs bottom and (b) of the beehive. under combs, at the bottom of the beehive.

BasedBased on on our our measurements, measurements, the the differences differences among sensor responses to gas sampled atat various points within a hive could be la large.rge. For example, the placement of the probe nearnear the beehivebeehive exitexit usually usually resulted resulted in in strongly strongly fluctuating fluctuating sensor sensor signals. signals. The The exemplary exem- Sensors 2021, 21, x FOR PEER REVIEW plarymeasurement measurement results results collected collected in such in circumstancessuch circumstances are shown are shown in Figure in Figure9b. Contrarily, 9b.14 ofCon- 19

trarily,when the when air wasthe air sampled was sampled from the from space the between space between the combs, the sensor combs, signals sensor displayed signals dis- less playedvariability. less Thevariability. respective The examplerespective of example measurement of measurement results is shown results in is Figure shown9a. in Figure 9a.

(a) (b)

FigureFigure 9. 9.GasGas sensor sensor responses responses to beehive to beehive air when air when the probe the probe was waslocated: located: (a) between (a) between combs, combs, (b) near the beehive exit. (b) near the beehive exit.

InIn our our opinion, opinion, the the placement placement of of the the samp samplingling probe probe should should be be standardized, standardized, at at a a fixedfixed location location with with respect respect to to the the hive, hive, such such as, as, e.g., e.g., at atthe the middle middle frame frame in inthe the brood brood box, box, oror with with respect respect to tothe the colony, colony, such such as, as, e.g., e.g., the the center center of of the the brood brood cluster. cluster. Theoretically, Theoretically, suchsuch an an approach approach allows allows to perform to perform sampling sampling at very at very precise precise locations locations within within the hive. the hive. In practice,In practice, it was it observed was observed that the that location the location of the of sampling the sampling probe probe changed changed over time. over It time. was It causedwas caused directly directly by the bybees’ the movement, bees’ movement, and indi andrectly, indirectly, by the byeffects the effectsof their of activity, their activity, e.g., thee.g., changing the changing size of sizethe ofbrood the broodclusters. clusters. Multi-point Multi-point sampling sampling at selected at selected points pointswas con- was sidered,considered, but in but our in opinion, our opinion, it was it too was invasive. too invasive.

4.2.3.4.2.3. Sample Sample Conditioning Conditioning Unit Unit InterferencesInterferences represent represent one one of of the the key key factors factors influencing influencing measuring measuring characteristics characteristics ofof gas gas sensing sensing devices. devices. They They may may result result from from numerous numerous sources. sources. The The identification identification and and quantificationquantification of of complex complex gas gas mixtures mixtures is isnega negativelytively affected affected in in the the presence presence of of chemical chemical interferencesinterferences above above the the expected expected levels. levels. Some Sometimes,times, the sample the sample conditioning conditioning system system de- signeddesigned for the for removal the removal of interfering of interfering substances substances helps helps to reduce to reduce this problem. this problem. For the For ap- the plicationapplication in question, in question, we considered we considered the incorporation the incorporation of filtration of filtration and drying and drying of the sam- of the pledsampled gas. gas. Beehive air contains gases as well as particulate matter. Particulate filters, installed in holders, were used to extract the solid particles from the sampled gas. Glass fiber, pol- ytetrafluoroethylene (PTFE) and nylon filters were tested. Finally, PTFE filters with a high retention rate and long service life were applied in the sampling system, inside the instru- ment—see Figure 3. It was assumed that their replacement would be carried out by a qualified technical service, once per season. Additionally, syringe nylon filters 25 mm, 0.45µm were applied. They were mounted externally on the sample gas line, between the beehive and the measurement device and at the end of air sampling line—see Figure 1. They provided the first step protection of sensors against the solid particles contained in the beehive and atmospheric air. These filters were recommended for replacement after one day of measurements. The exchange was easy, so filter cleaning was not practiced. In gas sensor measurements, the most common interference results from water va- por. The sensor sensitivity to this compound is a very serious weakness in an electronic nose technology because the signals generated in the semiconductor as sensors are strongly affected by gas humidity changes. In our studies, the permeation dryer based on a bundle of Nafion tubes was tested in view of applying it for beehive air sample condi- tioning. Nafion is a copolymer of tetrafluoroethylene (Teflon) and perfluoro-3,6-dioxa-4- methyl-7-octene-sulphonic acid. This material is highly selective in the removal of water, while most of other substances are retained quantitatively. However, although they do not attack or damage the Nafion tubing, some polar organic substances are absorbed by it and consequently lost from the gas sample. The integrity of the sample is not preserved.

Sensors 2021, 21, 4019 14 of 18

Beehive air contains gases as well as particulate matter. Particulate filters, installed in holders, were used to extract the solid particles from the sampled gas. Glass fiber, polytetrafluoroethylene (PTFE) and nylon filters were tested. Finally, PTFE filters with a high retention rate and long service life were applied in the sampling system, inside the instrument—see Figure3. It was assumed that their replacement would be carried out by a qualified technical service, once per season. Additionally, syringe nylon filters 25 mm, 0.45µm were applied. They were mounted externally on the sample gas line, between the beehive and the measurement device and at the end of air sampling line—see Figure1. They provided the first step protection of sensors against the solid particles contained in the beehive and atmospheric air. These filters were recommended for replacement after one day of measurements. The exchange was easy, so filter cleaning was not practiced. In gas sensor measurements, the most common interference results from water vapor. The sensor sensitivity to this compound is a very serious weakness in an electronic nose technology because the signals generated in the semiconductor as sensors are strongly affected by gas humidity changes. In our studies, the permeation dryer based on a bundle of Nafion tubes was tested in view of applying it for beehive air sample conditioning. Nafion is a copolymer of tetrafluoroethylene (Teflon) and perfluoro-3,6-dioxa-4-methyl- Sensors 2021, 21, x FOR PEER REVIEW 7-octene-sulphonic acid. This material is highly selective in the removal of water,15 whileof 19

most of other substances are retained quantitatively. However, although they do not attack or damage the Nafion tubing, some polar organic substances are absorbed by it and consequently lost from the gas sample. The integrity of the sample is not preserved. Figure 10 presents the results of the laboratory experiment, where we tested the gas sensor Figure 10 presents the results of the laboratory experiment, where we tested the gas sensor responses to dry and humid air containing ethanol vapors, as an example of polar VOCs. responses to dry and humid air containing ethanol vapors, as an example of polar VOCs. The gas sensor response to dried air containing ethanol decreased, when the sample The gas sensor response to dried air containing ethanol decreased, when the sample passed passed the Nafion dryer prior to sensor measurement (Figure 10a). Clearly, some ethanol the Nafion dryer prior to sensor measurement (Figure 10a). Clearly, some ethanol was was removed from the gas sample due to this operation. Similar observation was made removed from the gas sample due to this operation. Similar observation was made for for humid air containing ethanol vapors. Sensor responses were changed when gas sam- humid air containing ethanol vapors. Sensor responses were changed when gas sample ple passed Nafion dryer prior to measurement (Figure 10b), while relative humidity re- passed Nafion dryer prior to measurement (Figure 10b), while relative humidity reduction duction was limited. Based on the experiments, we concluded that the application of was limited. Based on the experiments, we concluded that the application of Nafion dryers Nafion dryers for beehive air sample conditioning is limited. for beehive air sample conditioning is limited.

(a) (b)

FigureFigure 10. 10. (a)( aGas) Gas sensor sensor responses responses to todried dried air, air, which which contained contained ethanol ethanol vapors vapors when: when: (left) (left) sample sample waswas transferred transferred directly directly to tothe the measuring measuring device device and and (right) (right) and and sample sample passed passed the the Nafion Nafion dryer dryer prior to measurement. (b) Gas sensor responses to humid air, which contained ethanol vapors when: prior to measurement. (b) Gas sensor responses to humid air, which contained ethanol vapors when: (left) sample was transferred directly to the measuring device and (right) and sample passed the (left) sample was transferred directly to the measuring device and (right) and sample passed the Nafion dryer prior to measurement. Nafion dryer prior to measurement. In general, the elimination of chemical interferences is one of the greatest challenges In general, the elimination of chemical interferences is one of the greatest challenges in practical applications of gas sensing devices. This problem has not been solved yet. The in practical applications of gas sensing devices. This problem has not been solved yet. The sample conditioning systems can have a negative influence on the representativeness of sample conditioning systems can have a negative influence on the representativeness of beehivebeehive air air measurements. measurements. In In our approach,approach, interferences interferences resulting resulting from from water water vapor vapor were weretaken taken into into account account at the at levelthe level of the of measurementthe measurement data data processing. processing.

4.2.4. System of Gas Delivery The system of gas delivery was designed to transport a volume of the beehive air from the sampling point to the measurement chamber and to maintain the gas composi- tion throughout the sampling system for the sensor measurement. It included a gas line, valves to control the gas flow and gas mover (a pump). The gas delivery system cannot cause degradation and loss of the sampled gas prior to measurements. The chemical complexity of beehive air must be maintained. The ap- propriate tubing can reduce the chance of sample decomposition. Sample lines must be made of inert material. Polytetrafluoroethylene (PTFE) was selected as a tubing material inside the sensor device. Outside, polyethylene tubing was used. Adsorption of beehive air components on the surface of this material was low. However, oftentimes, condensate was formed on the inner wall of the tubes. The water condensation played the main role in this process. During sampling, the gas sample inside the tube is under the influence of ambient conditions. Physical conditions inside and outside the beehive are usually differ- ent. The brood nest temperature is of extreme importance to the colony, and it is controlled with the utmost precision. Honey bees maintain the temperature of the brood nest be- tween 32 °C and optimally 35 °C. The relative humidity inside the beehive is not constant. The bees try to maintain an average humidity value of 60% inside. The maximum amount of water vapor that can be present in beehive air before it condenses (reach the saturation

Sensors 2021, 21, 4019 15 of 18

4.2.4. System of Gas Delivery The system of gas delivery was designed to transport a volume of the beehive air from the sampling point to the measurement chamber and to maintain the gas composition throughout the sampling system for the sensor measurement. It included a gas line, valves to control the gas flow and gas mover (a pump). The gas delivery system cannot cause degradation and loss of the sampled gas prior to measurements. The chemical complexity of beehive air must be maintained. The appropriate tubing can reduce the chance of sample decomposition. Sample lines must be made of inert material. Polytetrafluoroethylene (PTFE) was selected as a tubing material inside the sensor device. Outside, polyethylene tubing was used. Adsorption of beehive air components on the surface of this material was low. However, oftentimes, condensate was formed on the inner wall of the tubes. The water condensation played the main role in this process. During sampling, the gas sample inside the tube is under the influence of ambient conditions. Physical conditions inside and outside the beehive are usually different. The brood nest temperature is of extreme importance to the colony, and it is controlled with the utmost precision. Honey bees maintain the temperature of the brood nest between 32 ◦C Sensors 2021, 21, x FOR PEER REVIEW ◦ 16 of 19 and optimally 35 C. The relative humidity inside the beehive is not constant. The bees try to maintain an average humidity value of 60% inside. The maximum amount of water vapor that can be present in beehive air before it condenses (reach the saturation point) point)depends depends almost almost entirely entirely upon the upon outside the ou temperature.tside temperature. The water The condensate water condensate was formed was formedin the delivery in the delivery system, system, when thewhen temperature the temperature of the of tube the walls tube walls was lower was lower than thethan dew the dewpoint point of the of gas the sample. gas sample. Such Such an effect an effect was observedwas observed during during our measurementour measurement sessions ses- sionsmany many times, times, as shown as shown in Figure in Figure 11. 11.

(a) (b)

Figure 11. Condensate, whichFigure was formed11. Condensate, inside gas which line, during was formed beehive inside air measurements: gas line, during (a) initially beehive condensate air measurements: adheres (a) to the walls of the tubing, (binitially) later, the condensate amount of adheres condensate to the may walls be of sufficient the tubing, to block (b) later, the tubing. the amount of condensate may be sufficient to block the tubing. The water condensation has an adverse impact on the measuring equipment and mustThe be eliminated.water condensation If it occurs, has there an adverse is a risk impact that the on first the step measuring filter will equipment be completely and mustwettened. be eliminated. In turn, theIf it firstoccurs, step there filter is wettinga risk that is the reflected first step in gasfilter sensor will be signals. completely The wettened.exemplary In measurement turn, the first results, step filter which wetting illustrate is reflected such a situation,in gas sensor are shownsignals. in The Figure exem- 12. plaryThe first measurement three sets of results, sensor which signals illustrate were recorded such a whensituation, the firstare shown step filter in Figure was dry. 12. DueThe firstto filter three wetting, sets of signalssensor suddenlysignals were decreased, recorded and when they the remained first step at filter the new was low dry. level. Due Into filtersuch awetting, case, the signals composition suddenly of thedecreased, measured and gas they sample remained does notat the reflect new the low beehive level. airIn suchcomposition. a case, the The composition sample is not of representativethe measured gas and sample the measurement does not reflect results the are beehive erroneous. air composition.Water vapor The sample condensation is not representative poses a risk of and the the first measurement step filter clogging. results are When erroneous. unno- ticed, it may lead to the damage of the electronic elements of the sensor device, and also the pump. Transfer lines may be heated to prevent water condensation during sample transport when a temperature drops below the dew point. We developed a heated sample line in this study. It consists of PTFE tubing surrounded by the heating coil and insulation with an outer protective sleeve. A spiral-wound heating element for uniform heat distribution was used. Silicone or elastomer foam was used as the thermal isolation. Electricity for the heated sample line was supplied from batteries, which power the sensor device. The power consumption of the heated gas line was 7 W, which is high compared with the power consumption of the gas sensing device without it (see Section 3.1). The heated sample lines

Figure 12. Sensor signals change due to wetting of the first step filter. Wetting took place after the third test measurement.

Water vapor condensation poses a risk of the first step filter clogging. When unno- ticed, it may lead to the damage of the electronic elements of the sensor device, and also the pump. Transfer lines may be heated to prevent water condensation during sample transport when a temperature drops below the dew point. We developed a heated sample line in this study. It consists of PTFE tubing surrounded by the heating coil and insulation with an outer protective sleeve. A spiral-wound heating element for uniform heat distribution was used. Silicone or elastomer foam was used as the thermal isolation. Electricity for the heated sample line was supplied from batteries, which power the sensor device. The power consumption of the heated gas line was 7 W, which is high compared with the power consumption of the gas sensing device without it (see Section 3.1). The heated sam- ple lines should be lightweight and flexible. In practice, it is difficult to fulfil this require- ment. Our heated sample line caused logistic problems.

Sensors 2021, 21, x FOR PEER REVIEW 16 of 19

point) depends almost entirely upon the outside temperature. The water condensate was formed in the delivery system, when the temperature of the tube walls was lower than the dew point of the gas sample. Such an effect was observed during our measurement ses- sions many times, as shown in Figure 11.

(a) (b) Figure 11. Condensate, which was formed inside gas line, during beehive air measurements: (a) initially condensate adheres to the walls of the tubing, (b) later, the amount of condensate may be sufficient to block the tubing.

The water condensation has an adverse impact on the measuring equipment and must be eliminated. If it occurs, there is a risk that the first step filter will be completely wettened. In turn, the first step filter wetting is reflected in gas sensor signals. The exem- Sensors 2021, 21, 4019 plary measurement results, which illustrate such a situation, are shown in Figure 12.16 The of 18 first three sets of sensor signals were recorded when the first step filter was dry. Due to filter wetting, signals suddenly decreased, and they remained at the new low level. In suchshould a case, be lightweight the composition and flexible. of the measured In practice, gas it issample difficult does to fulfil not reflect this requirement. the beehive Ourair composition.heated sample The line sample caused is not logistic representative problems. and the measurement results are erroneous.

FigureFigure 12. 12. SensorSensor signals signals change change due due to to wetting wetting of of the the fi firstrst step step filter. filter. Wetting Wetting took took place place after after the the thirdthird test test measurement. measurement.

WaterThe problem vapor condensation of water condensation poses a risk could of th bee partially first step solved filter clogging. by adjusting When the unno- length ticed,of the it sample may lead line. to Itthe must damage be as of short the electr as possible,onic elements with no of bends the sensor between device, the samplingand also thepoint pump. and the gas sensing device. The short residence time of the tested gas in the sampling systemTransfer is very lines important. may be heated The samplingto prevent system water condensation in our work during had a samplesample transport residence whentime lessa temperature than 1.5 s. drops However, below water the condensationdew point. We was developed sometimes a heated observed. sample Therefore, line in thisinspection study. It of consists the gas lineof PTFE by the tubing beekeeper surrou isnded recommended. by the heating coil and insulation with an outerDynamic protective sampling sleeve. is A liable spiral-wound for leakage. he However,ating element for assuring for uniform gas sample heat distribution integrity, it wasis not used. allowed Silicone that or the elastomer tested gas foam becomes was used diluted as the by thermal the atmospheric isolation. air Electricity during transferfor the heatedto the sensorsample chamber. line was Therefore,supplied from the appropriate batteries, which construction power andthe gas-tightnesssensor device. of The the powersampling consumption system is aof principal the heated requirement. gas line was In field7 W, conditions, which is high connectors compared and with adapters the powerplay an consumption especially important of the gas role. sensing Quick device fastening without gas-tight it (see connectionsSection 3.1). wereThe heated successfully sam- pleused. lines The should sampling be lightweight system must and be flexible. regularly In examinedpractice, it and is difficult tested for to fulfil leaks. this require- ment.Pumps Our heated are required sample line in ordercaused to logistic convey problems. the sample to the sensor chamber. In our gas sensor device, we used the miniature eccentric diaphragm pump for gases SP 570 EC. Pulse-width modulation (PWM) was used for pump performance control. The beehive air was automatically aspirated by the pump at a prescribed flow rate and sampling time. The pump was located after the measuring unit. The pump had the capability to extract the gas from the beehive as well as to draw a reference air for cleaning operation. The flow capacity of the pump should be large enough to prevent long residence time of gas sample inside the measurement system. It has to be airtight because the beehive air cannot be diluted. Dynamic sampling requires power. In most realistic measuring systems, there is a limit of power supply. Thus, the power consumption of the pump has to be relatively low (see Section 3.1). It was not observed that the gas sensing device operation in field conditions imposed the need for frequent replacement of the sampling system components, except for the first step filters. However, proper maintenance of all sampling equipment is vital to the proper operation of the measuring device. The sample probe and gas lines must not be clogged or somehow obstructed. They should be kept clean and dry, free of water condensate.

5. Conclusions This paper discussed the selected issues regarding the application of gas sensing devices in beekeeping. They are beehive air sampling and the operation of the instrument, which is subordinate to the sampling method. Our attention was mainly focused on the impact of the environmental factors (beehive and ambient environments), as they significantly affect measurement results and gas sensing device operation in field conditions. The main conclusions are as follows: Sensors 2021, 21, 4019 17 of 18

• Dynamic sampling allows for the collection of representative samples of beehive air, and its unobstructed delivery to sensors chamber, which results in high accuracy of measurement. Proper gas flow rate selection is crucial. • The ‘exposure-cleaning’ operation allows for performing short-term measurements as well as long-term monitoring of beehive air. It prevents measurement bias and assures good temporal resolution of the acquired information. An adequate duration of exposure and cleaning operations is important. • The sampling system cannot change the composition of the gas sample. Proper construction materials are needed for this purpose; we chose PTFE and PE. • The sample probe geometry has to be defined on the basis of the intended localization of the sampling point in the beehive. Assess constraints apply. • The location of the sampling point in the beehive should be strictly defined, as it influences gas sensor responses. • The sampling system has to be fitted with elements that protect the sensing device from particulate matter and water condensate. This role is fulfilled by adequate filters. A Nafion drier was excluded as it changed the chemical composition of the gas sample. • Elements of the sampling system have to be checked, cleaned, dried, or replaced as a part of regular daily maintenance of the gas sensing device. It is necessary for attaining proper measurement results and to prevent the damage of the instrument. We believe that the information presented in this paper is valuable for designers and constructors of gas sensing devices. We draw attention to the problems that have a general character, while their solutions are heavily dependent on the kind of application. We hope that sharing our knowledge and experience will contribute to progress in developing gas sensing devices for apiculture.

Author Contributions: Conceptualization, A.S.; methodology, A.S. and M.M.; software, M.M.; validation, A.S. and M.M.; formal analysis, A.S. and M.M.; investigation, A.S. and M.M.; resources, A.S.; data curation, M.M.; writing—original draft preparation, A.S. and M.M.; writing—review and editing, A.S. and M.M.; visualization, M.M.; supervision, A.S.; project administration, A.S.; funding acquisition, A.S. All authors have read and agreed to the published version of the manuscript. Funding: This research was funded by the National Centre for Research and Development under grant no. BIOSTRATEG3/343779/10/NCBR/2017. Institutional Review Board Statement: Not applicable. Informed Consent Statement: Not applicable. Data Availability Statement: Data sharing is subject to restrictions. Acknowledgments: We would like to greatly acknowledge the owners and the personnel of apiaries, where we performed the field study in summer 2020. We were moved by their professionalism, open- ness, and welcoming attitude. They shared with us precious knowledge, which highly influenced our thinking about measurement solutions for beekeeping. Conflicts of Interest: The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.

References 1. Gallai, N.; Salles, J.M.; Settele, J.; Vaissière, B.E. Economic valuation of the vulnerability of world agriculture confronted with decline. Ecol. Econ. 2009, 68, 810–821. [CrossRef] 2. Watson, K.; Stallins, J.A. Honey Bees and Colony Collapse Disorder: A Pluralistic Reframing. Geogr. Compass 2016, 10, 222–236. [CrossRef] 3. Sperandio, G.; Simonetto, A.; Carnesecchi, E.; Costa, C.; Hatjina, F.; Tosig, S.; Gilioli, G. Beekeeping and honey bee colony health: A review and conceptualization of beekeeping management practices implemented in . Sci. Total Environ. 2019, 696, 133795. [CrossRef] 4. Zacepins, A.; Stalidzans, E.; Meitalovs, J. Application of information technologies in precision apiculture. In Proceedings of the 13th International Conference on Precision Agriculture (ICPA 2012), Indianapolis, IN, USA, 20–23 July 2012. Sensors 2021, 21, 4019 18 of 18

5. Bozek, K.; Hebert, L.; Portugal, Y.; Stephens, G.J. Markerless tracking of an entire honey bee colony. Nat. Commun. 2021, 12, 1733. [CrossRef] 6. Ferrari, S.; Silva, M.; Guarino, M.; Berckmans, D. Monitoring of swarming sounds in bee hives for early detection of the swarming period. Comput. Electron. Agric. 2008, 64, 72–77. [CrossRef] 7. Sánchez, V.; Gil, S.; Flores, J.M.; Quiles, F.J.; Ortiz, M.A.; Luna, J.J. Implementation of an electronic system to monitor the thermoregulatory capacity of honeybee colonies in hives with open-screened bottom boards. Comput. Electron. Agric. 2015, 119, 209–216. [CrossRef] 8. Meikle, W.G.; Weiss, M.; Maes, P.W.; Fitz, W.; Snyder, L.A.; Sheehan, T.; Mott, B.M.; Anderson, K.E. Internal hive temperature as a means of monitoring honey bee colony health in a migratory beekeeping operation before and during winter. Apidologie 2017, 48, 666–680. [CrossRef] 9. Bilik, S.; Kratochvila, L.; Ligocki, A.; Bostik, O.; Zemcik, T.; Hybl, M.; Horak, K.; Zalud, L. Visual Diagnosis of the Parasitic Mite in Honeybees Using Object Detector Techniques. Sensors 2021, 21, 2764. [CrossRef] 10. Arenas, A.; Fernandez, V.M.; Farina, W.M. Floral scents experienced within the colony affect long-term foraging preferences in honeybees. Apidologie 2008, 39, 714–772. [CrossRef] 11. Mas, F.; Horner, R.; Brierley, S.; Harper, A.; Suckling, D.M. The Scent of Individual Foraging Bees. J. Chem. Ecol. 2020, 46, 524–533. [CrossRef][PubMed] 12. Edwards-Murphy, F.; Magno, M.; Whelan, P.M.; O’Halloran, J.; Popovici, E.M. b+WSN: Smart beehive with preliminary decision tree analysis for agriculture and honey bee health monitoring. Comput. Electron. Agric. 2016, 124, 211–219. [CrossRef] 13. El-Wahed, A.A.A.; Farag, M.A.; Eraqi, W.A.; Mersal, G.A.M.; Zhao, C.; Khalifa, S.A.M.; El-Seedi, H.R. Unravelling the beehive air volatiles profile as analysed via solid-phase microextraction (SPME) and chemometrics. J. King Saud Univ. Sci. 2021, 33, 101449. [CrossRef] 14. Cecchi, S.; Terenzi, A.; Orcioni, S.; Spinsante, S.; MarianiPrimiani, V.; Moglie, F.; Ruschioni, S.; Mattei, C.; Riolo, P.; Isidoro, N. Multi-sensor platform for real time measurements of honey bee hive parameters. IOP Conf. Series Earth Environ. Sci. 2019, 275, 012016. [CrossRef] 15. Meikle, W.G.; Holst, N. Application of continuous monitoring of honeybee colonies. Apidologie 2015, 46, 10–22. [CrossRef] 16. Cheng, L.; Meng, Q.-H.; Lilienthal, A.J.; Qi, P.F. Development of compact electronic noses: A review. Meas. Sci. Technol. 2021, 32, 062002. [CrossRef] 17. Szczurek, A.; Maciejewska, M.; B ˛ak,B.; Wilk, J.; Wilde, J.; Siuda, M. Gas sensor array and classifiers as a means of varroosis detection. Sensors 2020, 20, 117. [CrossRef] 18. Szczurek, A.; Maciejewska, M.; B ˛ak,B.; Wilk, J.; Wilde, J.; Siuda, M. Detecting varroosis using a gas sensor system as a way to face the environmental threat. Sci. Total Environ. 2020, 722, 1–10. [CrossRef][PubMed] 19. Borecki, M.; Duk, M.; Kociubi´nski,A.; Korwin-Pawlowski, M.L. Multiparametric Methane Sensor for Environmental Monitoring. In Proceedings of the SPIE 10175, Electron Technology Conference 2016, Wisla, Poland, 22 December 2016; Volume 10715, p. 101750M. 20. Miskell, G.; Salmond, J.; Grange, S.; Weissert, L.; Henshaw, G.; Williams, D. Reliable Long-Term Data from Low-Cost Gas Sensor Networks in the Environment. Proceedings 2017, 1, 400. [CrossRef] 21. Zhang, Y.; Szabo, C.; Sheng, Q.Z. Cleaning Environmental Sensing Data Streams Based on Individual Sensor Reliability. In Lecture Notes in Computer Science, Proceedings of the Web Information Systems Engineering—WISE 2014, Thessaloniki, , 12–14 October 2014; Benatallah, B., Bestavros, A., Manolopoulos, Y., Vakali, A., Zhang, Y., Eds.; Springer: Cham, Switzerland, 2014; Volume 8787. 22. Betty, C.A.; Choudhury, S.; Girija, K.G. Reliability studies of highly sensitive and specific multi-gas sensor based on nanocrystalline SnO2 film. Sens. Actuators B Chem. 2014, 193, 484–491. [CrossRef] 23. Szczurek, A.; Maciejewska, M. Gas sensing method applicable to real conditions. Meas. Sci. Technol. 2013, 24, 045103. [CrossRef] 24. Szczurek, A.; Maciejewska, M.; Zelek, M. Influence of gas sampling on MOS response in real measurement conditions. Procedia Eng. 2014, 87, 588–591. [CrossRef] 25. Figaro Sensor. Available online: https://www.figaro.co.jp/en/product/sensor/ (accessed on 6 June 2021). 26. Szczurek, A.; Maciejewska, M.; Zajiczek, Z.;˙ B ˛ak,B.; Wilk, J.; Wilde, J.; Siuda, M. The effectiveness of Varroa destructor infestation classification using an E-nose depending on the time of day. Sensors 2020, 20, 2532. [CrossRef][PubMed] 27. Szczurek, A.; Maciejewska, M.; B ˛ak, B.; Wilk, J.; Wilde, J.; Siuda, M. Beehive indoor air measurement for bee colony diagnostics. In Indoor Air 2020: Creative & Smart Solutions for Better Built Environments, Proceedings of the 16th Conference of the International Society of Indoor Air Quality & Climate, Seoul, Korea, 1 November 2020; The International Society of Indoor Air Quality & Climate: Philadelphia, PA, USA, 2020; pp. 2439–2444.