Diffractive Corneal Inlay for Presbyopia 8 9 Walter D

Total Page:16

File Type:pdf, Size:1020Kb

Diffractive Corneal Inlay for Presbyopia 8 9 Walter D J. Biophotonics 10, 1110–1114 (2017) / DOI 10.1002/jbio.201600320 1 2 3 4 5 LETTER 6 7 Diffractive corneal inlay for presbyopia 8 9 Walter D. Furlan,* ,1 Salvador Garcı´a-Delpech,2 Patricia Udaondo,2 Laura Remo´n,3 10 Vicente Ferrando,4 and Juan A. Monsoriu4 11 12 1 13 Departmento de Óptica y Optometría y Ciencias de la Visión, Universitat de València, 46100, Spain 2 14 Ophthalmology Department, Hospital Universitario La Fe, Valencia, 46026, Spain 3 15 Departamento de Física Aplicada, Universidad de Zaragoza, España 4 16 Centro de Tecnologías Físicas, Universitat Politècnica de València, Valencia, 46022, Spain 17 Received 18 December 2016, revised 13 April 2017, accepted 27 April 2017 18 19 Keywords: Presbyopia, refractive surgery, cornea, diffractive lenses 20 21 22 23 A conceptually new type of corneal inlays for a custom- roundings of the far and near foci, are also shown. 24 ized treatment of presbyopia is presented. The dif- Picture: Simulation of the appearance of the Diffractive 25 fractive inlay consists on a small aperture disc having an corneal inlay on a real eye. 26 array of micro-holes distributed inside the open zones of 27 a Fresnel zone plate. In this way, the central hole of the 28 disc lets pass the zero order diffraction and produces an 29 extension of the depth of far focus of the eye, while the 30 diffracted light through the holes in the periphery pro- 31 duce the near focus. Additionally, the micro-holes in the 32 inlay surface fulfill the essential requirement of allowing 33 the flow of nutrients through it to the cells of the cor- 34 neal stroma. Theoretical and optical-bench ex- 35 perimental results for the polychromatic axial Point 36 Spread Function (PSF) were obtained, showing an im- 37 proved performance compared to the small aperture 38 corneal inlay currently in the market (Kamra). Images 39 of a test object, obtained at several vergences in the sur- 40 41 42 43 1. Introduction the refractive index, or its curvature [2]. On the oth- 44 er hand, the small aperture corneal inlay, commer- 45 The treatment of presbyopia has been historically cially known as KamraTM (AcuFocus, Irvine, CA, 46 addressed from different perspectives: from spec- USA), is based on the pinhole effect, thanks to 47 tacles and contact lenses [1], to surgical approaches which it is possible to increase the depth of focus 48 [2]. The most recent alternative is the use of intra- (DOF) of the eye, providing good vision at inter- 49 corneal implants, also known as corneal inlays. Ac- mediate and short distances. The Kamra inlay is an 50 cording to their physical properties, this type of im- opaque (black) thin ring of polyvinylidene fluoride 51 plants can be divided in two main groups. On the (PVDF) with 3.8 mm diameter and a central aper- 52 one hand, refractive inlays are intended to locally ture of 1.6 mm [2,3]. It has 8,400 micro-holes 53 modify the power of the cornea by changing either, (of 5–11 mm diameter) randomly distributed in its 54 55 56 * Corresponding author: e-mail: [email protected] © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim J. Biophotonics 10 (2017) 1111 1 surface for facilitating the flow of nutrients to the 2 cells of the corneal stroma. With these dimensions, 3 the Kamra let pass through the central hole only 4 about 20 % of the light that reaches it, and around 5 5 % is diffracted through the permeable material. 6 Therefore, it is implanted only in one eye (mono- 7 vision). In spite of the good clinical outcomes, the 8 small aperture inlay has some shortcomings. A sig- 9 nificant reduction in the contrast sensitivity of the 10 surgical eye has been reported [3]; which is caused 11 by the combination of the small aperture (pinhole 12 effect) and the diffracted light by the micro-holes in 13 the opaque ring. Additionally, under low illumina- 14 tion, the use of a small aperture inlay could make 15 reading difficult, and also can cause problems in 16 stereoscopic acuity due to the differences between 17 the luminance of retinal images [4,5]. 18 In this letter we present a conceptually new ampli- 19 tude corneal inlay, with improved light throughput. 20 This Diffractive Corneal Inlay (DCI), in addition to 21 produce an extension of the depth for the far focus of 22 the eye, it creates a near focus taking advantage to the 23 light diffracted by the nutrient micro-holes in its sur- 24 face. Numerical simulations of the axial PSF are pre- 25 sented for different pupil diameters. The improved fo- 26 cusing and imaging performance of the DCI is Figure 1 a) Diffractive Corneal Inlay (DCI) (see the main 27 demonstrated with experiments performed under pol- text for details of design parameters); b) Small aperture 28 ychromatic illumination in an optical bench. inlay with the dimensions of the Kamra. Dashed red lines 29 in a) and b) represent the 3 and 5 mm diameter pupil. c) Monochromatic theoretical axial PSFs for 45 nm (blue 30 line), 550 nm (green line) and 650 nm (red line) computed 31 2. Diffractive inlay design for a 3 mm pupil diameter (c) and 5 pupil diameter (e). d) 32 and f) Idem c) and d) but computed for the small aperture 33 The main idea behind the design of the DCI is to inlay. 34 exploit the intrinsic diffraction produced by the nu- 35 trient-permeable micro holes, redistributing them in 36 annular zones that coincide with those of an ampli- 37 tude Fresnel zone plate (see Figure 1a), to create a by the light diffracted by the micro-holes in the an- 38 diffractive lens. A similar concept, called photon nuli (first diffraction order). Hence, the effects of 39 sieve, was proposed formerly by Kipp et al. [6] for the high diffraction orders on the far and near im- 40 focusing X-rays. ages are minimized, because of the destructive inter- 41 A photon sieve is in fact a variation on the Fres- ferences produced by the spatial distribution of the 42 nel zone plate, which instead of alternate trans- micro-holes [6,9]. Moreover, the spatial distribution 43 parent and opaque rings of equal area, is an opaque and diameter of micro-holes in each zone can also 44 disc with non-overlapping pinholes distributed in the be modified to obtain an optimized relative intensity 45 corresponding transparent Fresnel zones. It was re- between the near and far foci, and/or to correct high 46 ported that photon sieves can achieve a sharper fo- order ocular aberrations. A typical example of a 47 cus by suppressing the secondary maxima and high- DCI is shown in Figure 1a. The construction param- 48 er-order diffraction effects as compared to a Fresnel eters are listed in Table 1, in comparison with the 49 zone plate [6–9]. Accordingly, the diffractive corneal only small aperture inlay available on the market: 50 inlay (DCI) here proposed, is a single micro- the Kamra, shown Figure 1b. 51 structured device (with any substrate) that combines As can be noted, in this particular example the 52 the concepts of small aperture inlay and photon distribution of the micro-holes in Figure 1a alter- 53 sieve. Therefore, a DCI has two main foci: one, the nates an azimuthal sequence of two and three holes 54 far distance focus, which is formed mainly by the per zone. 55 light that passes through the central hole; and the To evaluate the focusing properties of the DCI 56 other one, the near distance focus, that is generated we have computed the axial irradiance provided by www.biophotonics-journal.org © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim 1112 W. D. Furlan et al.: Diffractive corneal inlay 1 Table 1 DCI and Kamara corneal inlays construction parameters. 2 3 Design wave- Addition Central External di- Total number of Maximum hole di- Minimum 4 length (Ad) hole ameter holes ameter hole di- 5 diameter ameter 6 DCI 550 nm 1.50 D 2.00 mm 4.15 mm 2,290 30.5 mm 18.8 mm 7 8 KAMRA 550 nm NA 1.60 mm 3.80 mm 8,400 11 mm5mm 9 10 11 both devices under plane wave coherent illumina- 12 tion. By using the Fresnel approximation, we nu- 13 merically computed monochromatic irradiances for 14 different wavelengths [10] and two pupil diameters: 15 3.00 mm and 5.00 mm. These pupils diameters were 16 selected because they are representative for people 17 from 40 to 60 years old, in bright and dim environ- 18 ments respectively [11] and also because they were 19 adopted in other studies dealing with Kamra [12]. 20 The results are shown in Figures 1c–1f. As expected, 21 the diffracted intensities are wavelength-dependent 22 with maximum irradiances for the design wave- 23 length. As can be noted in Figures 1e and 1f, the 24 5.00 mm pupil allows the light to pass outside the in- Figure 2 Scheme of the experimental setup employed to 25 lays increasing the values of the axial intensity, and obtain the polychromatic axial PSF.A 30 mm pin-hole 26 creating an interference pattern along the optical (PH) acts as a point object. LP 458 are linear polarizers to 27 axis. Note that, for each pupil diameter, the same allow the system to work in amplitude-only mode. L1 and 28 normalization was adopted to represent the results L2 are achromatic lenses of 200 mm focal length.
Recommended publications
  • The Kamra Corneal Inlay in the Clinic
    Clinical Update REFRACTIVE SURGERY The Kamra Corneal Inlay in the Clinic by leslie burling-phillips, contributing writer interviewing wayne crewe-brown, mb, chb, mmed, sheldon herzig, md, frcsc, and david g. kent, md, mbchb, franzco, fracs ommercially available in vantage of the inlay is that the distance Kamra in Place Europe, the Asia-Pacific vision compromise in the reading eye region, South America, and is significantly less than what is experi- the Middle East prior to FDA enced with monovision, where the pa- approval in April this year, tient must tolerate and accommodate Cthe Kamra corneal inlay (AcuFocus) for the distance vision blur created in now offers U.S. ophthalmologists an the reading eye,” said David G. Kent, alternative treatment for presbyopia. MD, MBChB, FRANZCO, FRACS, at According to the FDA, the device is the Fendalton Eye Clinic in Christ- indicated for phakic presbyopes be- church, New Zealand. tween the ages of 45 and 60 who do Studies. Long-term study results in- not require glasses or contact lenses for dicate that the inlay is a safe, effective, distance vision but have a near vision and reversible treatment for presby- correction need of +1.00 D to +2.50 D. opia. Patients in one study gained 2 or Three ophthalmologists—from New more lines of uncorrected near visual Zealand, Canada, and England—share acuity and did not show significant their experiences with the Kamra cor- loss in distance vision when evalu- neal inlay. ated 4 years after inlay implantation.1 The intrastromal pocket, created with Reading performance is also positively a pocket software–approved femtosec- How the Inlay Works affected.
    [Show full text]
  • CORNEAL INLAYS: RESEARCH and RESULTS Surgeons Provide an Update on Three Devices
    CORNEAL INLAYS: RESEARCH AND RESULTS Surgeons provide an update on three devices. Kamra most diagnostic equipment could still be used after the Kamra’s implantation. COVER FOCUS COVER BY R. LUKE REBENITSCH, MD Numerous studies in the United States and abroad have cor- roborated these results.12-15 In my experience with more than 100 The concept of corneal inlays is nothing new: Kamra inlays, I have had similar, if not better, results. José Barraquer, MD, has been credited with the original idea as early as the 1940s.1 The CONSIDERATIONS benefits of these implants are numerous— Comparison to Other Presbyopic Solutions reversibility, ease of repositioning, and pos- The Kamra has been shown to improve near vision across sible combination with previous and future the presbyopic age group, although those under the age of refractive correction. Early designs were asso- 50 experienced the greatest improvement.16 Results with ciated with difficulties such as vascularization, the inlay and IOLs were comparable, but there were some keratolysis, decentration, and poor biocompatibility.2-7 Only advantages with the latter modality for certain intermediate recently have technological advances overcome these con- and near demands.16 I now typically recommend the inlay to cerns. Approved by the FDA in April, the Kamra (AcuFocus) is patients under the age of 55 and refractive lens exchange to the first inlay available in the United States.8,9 those who are older than 55 years of age. There can be much Like most corneal inlays, the Kamra is implanted in the overlap, depending on the measured scatter within a patient’s patient’s nondominant eye.
    [Show full text]
  • One-Year Clinical Outcomes of a Corneal Inlay for Presbyopia
    CLINICAL SCIENCE One-Year Clinical Outcomes of a Corneal Inlay for Presbyopia Sandra M. C. Beer, MD, Rodrigo Santos, MD, Eliane M. Nakano, MD, Flavio Hirai, MD, Enrico J. Nitschke, Claudia Francesconi, MD, and Mauro Campos, MD phthalmologists have used a wide variety of procedures Purpose: To report the results of a 1-year follow-up analysis of the Oto correct for refractive errors. Corneal laser surgery safety and efficacy of the Flexivue Microlens corneal inlay. with multifocal patterns or monovision approaches have been Methods: The Flexivue Microlens corneal inlay was implanted in developed including laser-assisted in situ keratomileusis (LASIK),1,2 presbyLASIK,3 photorefractive keratectomy,4 the nondominant eye of patients with emmetropic presbyopia 5 2 laser epithelial keratomileusis thin-flap femto-LASIK, and (a spherical equivalent of 0.5 to 1.00 diopter) after the creation 6 7,8 of a 300-mm deep stromal pocket, using a femtosecond laser. The sub-Bowman keratomileusis. Conductive keratoplasty, patients were followed up according to a clinical protocol involving clear lens extraction, cataract surgery using multifocal, pseudoaccommodative intraocular lenses, or monovision refraction, anterior segment imaging analysis (Oculyzer), and optical 9–11 quality analysis (OPD-Scan). monofocal intraocular lenses have also been used to treat presbyopia. Results: Thirty-one patients were enrolled in this ongoing study. The necessity of a minimally invasive, removable, The mean age was 50.7 years (range 45–60 yrs), and 70% of the and safe surgical technique with a flat learning curve for patients were female. The mean uncorrected near visual acuity patients aged 45 to 60 years has led to the development of improved to Jaeger 1 in 87.1% of the eyes treated with the inlays.
    [Show full text]
  • COVER STORY Advantages of Corneal Inlays for Presbyopia
    COVER STORY Advantages of Corneal Inlays for Presbyopia Flexivue’s smart monovision technique is reversible and minimally invasive. BY IOANNIS PALLIKARIS, MD, PHD; DIMITRIOS BOUZOUKIS, MD; SOPHIA PANAGOPOULOU, PHD; AND ALICE LIMNOPOULOU, MD resbyopia is a multifactorial physiologic aging clear lens extraction are more invasive techniques. mechanism that leads to the progressive loss of The desire to develop a minimally invasive, reversible, sta- functional near vision. Scleral expansion surgery;1 ble, and safe surgical technique with an easy learning curve corneal laser surgery with multifocal patterns or for patients between the ages of 45 and 60 years—patients P 2 3 monovision approaches; conductive keratoplasty (CK); who could be considered too old for presbyopia corneal and clear lens extraction or cataract surgery using multifo- surgery and too young for lens extraction—led to the devel- cal, accommodating, or monovision monofocal IOLs4,5 are opment of a new approach based on the use of refractive among the techniques that have been used for the treat- corneal inlays. These devices are placed inside a tunnel cre- ment of presbyopia. Corneal laser surgery and CK are mini- ated in the corneal stroma. mally invasive methods, but they provoke irreversible The Flexivue Micro-Lens corneal inlay (Presbia changes in corneal anatomy, whereas scleral surgery and Coöperatief UA, Amsterdam, Netherlands) is a refractive hydrophilic polymer lens intended for insertion inside a corneal stromal tunnel in the nondominant eye. The lens’ central zone is free of refractive power, and the peripheral zone has a standard positive refractive power. The diameter of the Flexivue is 3 mm, and the thickness is less than 20 µm.
    [Show full text]
  • Corneal Inlay Implantation Complicated by Infectious Keratitis
    Downloaded from http://bjo.bmj.com/ on February 18, 2016 - Published by group.bmj.com Clinical science Corneal inlay implantation complicated by infectious keratitis Emma S Duignan,1 Stephen Farrell,1 Maxwell P Treacy,2 Tim Fulcher,2 Paul O’Brien,1 William Power,1 Conor C Murphy1,3 1Royal Victoria Eye and Ear ABSTRACT type of modern inlay, which was not encountered Hospital, Dublin, Ireland Background/aims To report five cases of infectious in this series, has a similar refractive index to the 2Mater Misericordiae University keratitis following corneal inlay implantation for the cornea and alters its refraction by changing the Hospital, Dublin, Ireland 2 3Department of surgical correction of presbyopia. anterior corneal curvature. The KAMRA inlay is Ophthalmology, Royal College Methods This was a retrospective, observational case an opaque, ring-shaped structure, 3.8 mm in diam- of Surgeons in Ireland, Dublin, series. Five eyes of five patients were identified eter, with a 1.6 mm central aperture that increases Ireland consecutively in two emergency departments during a the depth of focus by pinhole optics. It is com- fl 3 Correspondence to 1-year period, from November 2013 to November 2014. posed of polyvinylidene uoride and carbon. The Dr Emma S Duignan, Royal Patients’ demographics, clinical features, treatment and Flexivue Microlens inlay is a transparent circular Victoria Eye and Ear Hospital, outcomes are described. inlay, 3 mm in diameter, with a peripheral annular Adelaide Road, Dublin 2, Results There were four female patients and one male, refractive element and a central plano surface; it Ireland; [email protected] aged 52–64 years.
    [Show full text]
  • Small Aperture Technology
    Supplement October 2016 SMALL APERTURE TECHNOLOGY: Extending Depth of Focus for a Broad Spectrum of Presbyopic and Cataract Patients Supported by an educational grant from AcuFocus, Inc SMALL APERTURE OPTICS: A CONTINUOUS RANGE OF VISION Pinhole effect provides continuous extended, depth of focus without the disadvantages of monovision - Matteo Piovella, MD mall-aperture technology relies on the small With small aperture optics, the “near” eye still has excellent aperture, or pinhole effect to extend depth of distant vision, as described above. The visual system receives focus by blocking unfocused peripheral light two images that can be successfully converged. Pablo Artal rays and allowing only central light rays to reach PhD, and colleagues have demonstrated that small-aperture the retina. Initially introduced by AcuFocus, optics produce a benefit in stereoacuity compared to Inc. in the form of the KAMRA™ corneal inlay, it is now also monovision and that, even when a small aperture is combined S TM available for intraocular use. The IC-8 small aperture IOL with a small amount of mypoia, it preserves stereoacuity is a single-piece hydrophobic acrylic IOL embedded with a similar to that of normal binocular vision.1 central, opaque annular mask. The mask is 3.23 mm in overall Both patients and doctors can appreciate the benefits of diameter, with a 1.36-mm central opening, or aperture. implanting effective presbyopic IOL technology in one eye One year clinical data suggest that the IC-8 IOL functions only because it supports the most natural far vision with the like a premium lens with the ease of use of a monofocal IOL.
    [Show full text]
  • Corneal Remodeling for Refractive Errors – (0141)
    Medical Coverage Policy Effective Date ............................................10/15/2020 Next Review Date ......................................10/15/2021 Coverage Policy Number .................................. 0141 Corneal Remodeling for Refractive Errors Table of Contents Related Coverage Resources Overview .............................................................. 1 Intraocular Lens Implant Coverage Policy ................................................... 1 General Background ............................................ 4 Medicare Coverage Determinations .................. 19 Coding/Billing Information .................................. 19 References ........................................................ 21 INSTRUCTIONS FOR USE The following Coverage Policy applies to health benefit plans administered by Cigna Companies. Certain Cigna Companies and/or lines of business only provide utilization review services to clients and do not make coverage determinations. References to standard benefit plan language and coverage determinations do not apply to those clients. Coverage Policies are intended to provide guidance in interpreting certain standard benefit plans administered by Cigna Companies. Please note, the terms of a customer’s particular benefit plan document [Group Service Agreement, Evidence of Coverage, Certificate of Coverage, Summary Plan Description (SPD) or similar plan document] may differ significantly from the standard benefit plans upon which these Coverage Policies are based. For example, a customer’s benefit
    [Show full text]
  • Presbia Inc.) Corneal That Never Really Got Are Talking About Inducing Monovision Try to Improve Vision
    4 cover Story PRESBYOPIA PRESBYOPIA AND CORNEAL INLAYS Corneal inlays discover new lease of life as potential presbyopic treatment by Dermot McGrath he past few years have seen a Back to the future Given the current the inlays were eventually replaced by lasers resurgence of interest in corneal hype surrounding presbyopic inlays, it is which did the job more accurately,” he said. inlays as a potential treatment The Vue+/PresbyLens inlay (ReVision I think we need to perhaps easy to forget that the technology for presbyopia. Some surgeons has actually been around for a long time, optics Inc), currently undergoing clinical “keep an open mind have hailed the latest generation of inlay trials in the US, uses a refined version of this T said Daniel S Durrie MD, clinical professor and not rush to technologies as a breakthrough in the search of ophthalmology, University of Kansas approach, but changes the corneal curvature judgment on this for a universally effective and universally Medical Centre, and president, Durrie in the centre of the cornea only. promising technology applicable treatment for presbyopia. Vision, Kansas, US. The second type of inlay sought to change others warn that the marketing hype is “Corneal inlays for improving vision are the corneal power by putting a high index running ahead of the clinical reality and not a new concept. Back in the early 1980s refraction inlay in the cornea. José Güell MD that the inlay needs more hard data and we saw several different attempts at corneal “They ended up not being very permeable longer follow-up to assess its credentials as a inlays for the presbyopic market that never and the cornea biologically did not tolerate groundbreaking technology.
    [Show full text]
  • Refractive Surgery Issue • February 2014 • Review of Ophthalmology Vol
    MULTIMODAL IMAGING OF PLACOID DISORDERS P. 42 • WILLS RESIDENT CASE SERIES P. 67 NTG: THE NOCTURNAL BLOOD PRESSURE FACTOR P. 54 • WISE CHOICES FOR OCULAR DIAGNOSES P. 50 Review of Ophthalmology Vol. XXI, No. 2 • 2014 • February Refractive Surgery Issue • Glaucoma • Normal Tension Detection • New in Keratoconus Cataract Surgical Suite The NEW WAYS TO DETECT KERATOCONUS P. 58 • THE INTEGRATED CATARACT SURGICAL SUITE P. 18 February 2014 • revophth.com Refractive Surgery Issue Inlays and Presbyopia: On the Horizon P. 24 Crack a SMILE or Raise a Flap? P. 30 LASIK Xtra: Who Should Get It? P. 38 fc_rp0214.indd 1 1/27/14 3:47 PM ILEVRO™ Suspension Designed to put potency precisely where you need it 1,2 ONCE-DAILY POST-OP One drop should be applied once daily beginning 1 day prior to surgery through 14 days post-surgery, with an additional drop administered 30 to 120 minutes prior to surgery 3 Use of ILEVRO™ Suspension more than 1 day prior to surgery or use beyond 14 days post-surgery may increase patient risk and severity of corneal adverse events3 INDICATIONS AND USAGE ILEVRO™ Suspension is a nonsteroidal, anti-infl ammatory prodrug indicated Patients with complicated ocular surgeries, corneal denervation, corneal for the treatment of pain and infl ammation associated with cataract surgery. epithelial defects, diabetes mellitus, ocular surface diseases (e.g., dry eye Dosage and Administration syndrome), rheumatoid arthritis, or repeat ocular surgeries within a short period of time may be at increased risk for corneal adverse events which ™ One drop of ILEVRO Suspension should be applied to the affected eye may become sight threatening.
    [Show full text]
  • Refractive Surgery at a Crossroads
    2018 MEDICARE CODING UPDATE P. 19 • TORIC ALIGNMENT TECH P. 22 SUPPLEMENTS AND GLAUCOMA P. 40 • GORE-TEX SUTURING TRICKS P. 47 A REVIEW OF POSTERIOR SCLERITIS P. 50 • PEDIATRIC OCULAR ONCOLOGY P. 55 Review of Ophthalmology Vol. XXV, No. 2 • February 2018 • Presbyopic Corneal Inlays • Breakdown of Corneal • Breakdown Inlays 2018 • Presbyopic No. 2 • February Review of Ophthalmology Vol. XXV, FFebruaryebruary 22018018 reviewofophthalmology.comrreviiewofophthalmology.com NEW SCHOOL ANNUAL REFRACTIVE SURGERY ISSUESSUE Refractive Surgery OLD SCHOOL At A Crossroads New devices and procedures are emerging, but will they topple the tried-and-true? • Can Corneal Inlays Work forfor You?You? P. 26 • Breaking Down the SMILE ProcedureProcedure P. 3232 • Is There Still a Place for ManualManual LRIs?LRIs? P. 36 SMILE • • SMILE Manual LRIs • Toric Alignment Manual LRIs • Toric 001_rp0118_fc 2.indd 1 1/26/18 2:59 PM YOUR PATIENTS’ EYES TAKE IN A LOT. Sometimes it’s not all good. SYSTANE ® BALANCE Lubricant Eye Drops are scientifi cally formulated to work on all 3 layers of the tear fi lm, protecting the ocular surface with ingredients that increase lipid layer thickness by 40%.*,1 Recommend SYSTANE® BALANCE to your patients for the temporary relief of dry eye symptoms, and see how science leads to real relief. *Prospective, randomized, double-masked, single-dose, contralateral eye study, N=40. Lipid layer thickness was measured in nanometers, and baseline measurement was 63.38. The Relief is Real 1. Korb D, et al. Evaluation of extended tear stability by two emulsion based artifi cial tears. Poster presented at: 6th International Conference on the Tear Film and Ocular Surface: Basic Science and Clinical Relevance; September 22-25, 2010; Florence, Italy.
    [Show full text]
  • HOW IS EXTENDED DEPTH of FOCUS ACHIEVED with a SMALL-APERTURE LENS? the Pinhole Effect of the Kamra Inlay May Have Similar Efficacy When Transferred to an IOL
    HOW IS EXTENDED DEPTH OF FOCUS ACHIEVED WITH A SMALL-APERTURE LENS? The pinhole effect of the Kamra inlay may have similar efficacy when transferred to an IOL. BY PABLO ARTAL, PHD COVER FOCUS COVER Life happens on small and grand scales, through the central aperture. The IOL mask is 15% smaller right in front of us and from afar; most of in diameter than the one used in the Kamra inlay to us want to experience all of it. Since the first account for its more posterior placement. It also has fewer bifocal IOLs were developed in the 1980s, microperforations. scientists and manufacturers have been on Investigators collected data from more than 20,000 a dedicated mission to provide individuals patients worldwide with the Kamra inlay. They found with great vision at all distances after cata- that patients with the inlay gained a mean 3 lines of near ract surgery. visual acuity and 1 line of intermediate visual acuity, with a Following those early bifocal lenses, the development decrease of only 0.5 lines of monocular distance acuity and of multifocal lenses provided good vision at multiple dis- no decrease of binocular distance acuity.5 Results with the tances, and accommodative IOLs attempted to mimic the Kamra inlay remained stable over 60 months, even as pres- focusing ability of the natural eye. However, although many byopia progressed. of these options have been successful in achieving good In an eye with plano refraction, the small-aperture tech- visual acuity at distinct distances, this has often come at nique can provide an increased range of vision of about the price of decreased overall quality of vision.1-3 2.5 D.
    [Show full text]
  • The Kamra Inlay How This Premium Presbyopia Solution Can Improve Your Practice
    Supplement to January 2018 Sponsored by AcuFocus GOING MOD Simple Rules for Inlay Success GOING MOD The Kamra Inlay How this premium presbyopia solution can improve your practice. BY WILLIAM F. WILEY, MD he Kamra corneal inlay (AcuFocus) is currently our most pop- inlay performs its best when implanted in a slightly myopic (at least ular presbyopic solution, even ahead of presbyopia-correcting -0.75 D) eye. Most patients are not walking into the office with that TIOLs. Having now amassed a great deal of experience with the type of prescription, so in many instances, it is up to us to get the inlay, we are extremely confident in its ability to deliver safe and patient to that ideal refractive target prior to implanting the inlay. predictable postoperative results and in its capacity to extend our When this is achieved, we can maximize the function of the Kamra patients’ range of vision. inlay and get the patient in that perfect range for visual success. For this reason, we continue to use the Kamra inlay more fre- Ocular surface. Just like with any premium presbyopic quently and are excited to recommend it to our patients. The solution—multifocal IOLs, PRK, LASIK, and even refractive Kamra inlay compliments our other offerings and, generally speak- cataract surgery—it is important to first manage the ocu- ing, has helped to raise the awareness of refractive surgery. It has lar surface prior to implanting the Kamra inlay. Any high- also given us the ability to treat a wider range of patients and has performance optic is more sensitive to dry eye, and so address- increased our referral base, mainly because we have more happy ing that and controlling that prior to surgery is crucial.
    [Show full text]