(VCG) Parameters for Analyzing Repolarization Variability in ECG Signals

Total Page:16

File Type:pdf, Size:1020Kb

(VCG) Parameters for Analyzing Repolarization Variability in ECG Signals Biomed. Eng.-Biomed. Tech. 2016; 61(1): 3–17 Review Muhammad A. Hasan* and Derek Abbott A review of beat-to-beat vectorcardiographic (VCG) parameters for analyzing repolarization variability in ECG signals Abstract: Elevated ventricular repolarization lability is Introduction believed to be linked to the risk of ventricular tachycardia/ ventricular fibrillation. However, ventricular repolariza- The biological signals are generated within the human tion is a complex electrical phenomenon, and abnor- body through different physiological processes. These malities in ventricular repolarization are not completely signals are usually acquired in their raw form, and there- understood. To evaluate repolarization lability, vector- fore, it is required to carry out signal processing and cardiography (VCG) is an alternative approach where the analysis to reveal pertinent details. In the case of an electrocardiographic (ECG) signal can be considered as electrocardiographic (ECG) signal, the signal contains possessing both magnitude and direction. Recent research amplitude information without orientation of the heart has shown that VCG is advantageous over ECG signal vector direction. In clinical practice, the QT interval is analysis for identification of repolarization abnormality. measured as the duration of onset of Q wave and the One of the key reasons is that the VCG approach does not offset of T wave in the heart’s ECG electrical cycle, which rely on exact identification of the T-wave offset, which represents the global electrical repolarization of the ven- improves the reproducibility of the VCG technique. How- tricles. Note that QT-interval variability analysis from a ever, beat-to-beat variability in VCG is an emerging area single ECG beat demonstrates the static picture of repo- for the investigation of repolarization abnormality though larization abnormalities, but the beat-to-beat QT inter- not yet fully realized. Therefore, the purpose of this review val variability (QTV) establishes the dynamic changes is to explore the techniques, findings, and efficacy of beat- of the QT interval duration and repolarization labilities. to-beat VCG parameters for analyzing repolarization labil- Elevated beat-to-beat QTV is of interest as it has been ity, which may have potential utility for further study. associated with increased cardiovascular morbidity and mortality [10, 41, 42, 66, 72]. Keywords: electrocardiography (ECG); QT interval vari- However, recent findings suggest that beat-to-beat ability; repolarization; vector electrocardiogram (VCG). QTV varies between leads in 12-lead ECG, where partial factors contributing to these QTV variations can be real- DOI 10.1515/bmt-2015-0005 ized through the study of T-wave amplitude [37, 40, 41]. Received November 8, 2014; accepted April 17, 2015; online first In particular, the magnitude and temporal pattern of May 20, 2015 beat-to-beat QTV varies significantly between leads in 12-lead ECG. Therefore, quantification of QTV in differ- ent leads is associated with their respective ECG leads. *Corresponding author: Muhammad A. Hasan, PhD, Department Consequently, QTV data from different studies in differ- of Electrical and Computer Engineering, Ryerson University, ent leads may lead to inconsistencies. Thus, caution must Toronto, ON M5B 2K3, Canada, Phone: +1-416-979-5000, ext. 2048, E-mail: [email protected]; [email protected]; be taken when comparing QTV results obtained from dif- Department of Electrical and Electronic Engineering, The University ferent leads across studies. Therefore, another modality of Adelaide, Adelaide, SA 5005, Australia; and Centre for Biomedical called vector electrocardiography [or vectorcardiography Engineering (CBME), The University of Adelaide, Adelaide, SA 5005, (VCG)] may be useful for the analysis of dynamic changes Australia of repolarization abnormalities. Here, VCG measures Derek Abbott: Department of Electrical and Electronic Engineering, The University of Adelaide, Adelaide, SA 5005, Australia; and Centre cardiac electrical forces with both magnitude and vecto- for Biomedical Engineering (CBME), The University of Adelaide, rial direction; it may be thought of as a methodological Adelaide, SA 5005, Australia elaboration of the ECG. 4 M.A. Hasan and D. Abbott: Beat-to-beat vectorcardiographic approach for repolarization variability These electrical forces are generated by billions of proceed throughout the ventricular mass of the heart cardiac cells in the heart that can be modeled as a contin- [62]. In addition, using VCG loops, it is easier to observe uous series of vectors that form a resultant. Moreover, VCG the direction and magnitude of the heart vector. Usually, aims at a spatial representation that reflects the electri- recorded ECG cannot explain both the direction and mag- cal activity of the heart in the three (perpendicular direc- nitude of the heart vector. However, to observe the direc- tions of X, Y, and Z) spatial planes as shown in Figure 1. tion and magnitude of the heart vector, the VCG signal is Note that VCG allows the concept of a dipole originated required. Now, the VCG signal can be directly recorded in the heart and uses orthogonal leads that define these via the Frank lead system or can be derived from the ECG three spatial planes: frontal, horizontal, and sagittal [31]. signal using a transform method [singular value decom- By contrast, the standard 12-lead ECG represents only the position (SVD) or inverse Dower transform (IDT)] or via one-dimensional scalar value of the heart function, i.e., matrix coefficients (Kors). In addition, VCG loops may it represents only the magnitude and not the direction or have clinical importance for detecting cardiac diseases spatial information of heart signal. Improved understand- such as myocardial infarction or myocardial injury in ing for analysis and characterization of heart signals by coronary surgery over conventional ECG analysis [19, 94], considering both direction and magnitude of the ECG which is not easy to observe from a scalar ECG signal. signals as a three-dimensional phenomenon may be then Therefore, it has been proposed over recent decades by possible using techniques based on VCG. various researchers that VCG has significant utility com- Further, by observing QRS- and T-wave loops, we may pared to the standard 12-lead standard ECG [13, 14, 60, 84]. obtain extra features, and this is of benefit for further As VCG represents the spatial and temporal information of observation and analysis during the progress of the the heart action, it is thought to be a very promising tool ventricle activation front. This is because it may require for diagnosis of heart diseases [12, 73, 93, 96] and also can a longer time for the evolution of the activation front to be extended as a marker for biometrics [1]. Therefore, this paper focuses on a review of tech- niques, findings, and efficacy of beat-to-beat VCG approach for analyzing repolarization abnormalities. Left sagittal -500 80ms 60ms Frontal 0ms Synthesis of VCG 0 20ms VCG from Frank (X, Y, and Z) lead 500 For clinical studies, the VCG signal is recorded directly from the surface of the body. However, in older studies, 1000 VCG was recorded from the body using a special approach 500 that directly provided the three orthogonal components 60ms 0 20ms of the dipole vector, based on the Frank VCG lead system 40ms 500 [25]. This system consists of seven electrodes. There are 40ms five electrodes in the transverse plane; one electrode is on -1500 1000 -1000 the back of the neck and one on the left foot, as shown in Horizontal -500 1500 0 Figure 2. By utilizing the Frank VCG lead system, a three- 500 dimensional representation of electrical heart activity Color map for time can be found directly by measuring ECG in three different 0ms to 20ms 60ms to 80ms directions (Figure 2), i.e., right-to-left (X-axis), head-to- 20ms to 40ms 80ms to 100ms feet (Y-axis), and front-to-back (Z-axis). 40ms to 60ms T Loop color There are a number of reasons why the Frank VCG lead system is no longer used for clinical practice, mainly due to its non-standard lead configuration. Hence, an impor- Figure 1: The basic principle of vectorcardiography (after [31]). Electrical activity of the heart in the three perpendicular directions tant current issue is to derive VCG from standard 12-lead X, Y, and Z. The P, QRS, and T wave loops are observed in three ECG for improving diagnosis of heart signals. Although, a different planes (sagittal, frontal, and horizontal). study demonstrated quantitatively for deriving VCG signal M.A. Hasan and D. Abbott: Beat-to-beat vectorcardiographic approach for repolarization variability 5 H proposed by Dower [22]. Another technique was intro- duced by Kors et al. [54] for synthesizing the VCG from z standard 12-lead ECG. These simple estimated transforma- tion matrices are most commonly used to synthesize the VCG from 12-lead ECG. However, a number of studies have M investigated the reliability of these estimated matrices, I where the findings showed that this type of transforma- tion has a number of limitations in achieving orthogonal x VCG reconstruction [32, 33, 63]. The main problem of the A proposed transform matrices is due to estimation during E C reconstruction that gives rise to potential information loss or even unwanted information. Furthermore, the derived orthogonal leads from 12-lead ECG by applying these matrices may differ from those obtained from the actual y VCG leads. However, an alternative technique using SVD is sug- gested by Acar and Koymen [2] for deriving the VCG from 12-lead standard ECG for a single ECG beat. Here, the SVD is applied to the eight independent leads (I, II, V1, V2, V3, V4, V5, and V6) of the standard 12-lead ECG configuration to obtain eight decomposed signals. The first three decom- posed signals comprise an ECG dipole (see Figure 3), and 99% of the ECG energy can be represented in a three- dimensional minimum subspace [2], which are similar F to the orthogonal components obtained from the Frank VCG.
Recommended publications
  • Good Quality Care Increases Hospital Profits Under Prospective Payment by David C
    Good quality care increases hospital profits under prospective payment by David C. Hsia and Cathaleen A. Ahern This study shows that, contrary to popular belief, the overlooked because ofthis skimping. After deduction prospective payment system discourages skimping on for the cost ofthe omitted services and probability of medically indicated care. The quality ofcare on a negative diagnostic tests, good quality care would have nationally representative sample ofMedicare discharges increased hospital profits a significant 7.9 percent. As underwentjudgmental review using implicit criteria. the specificity ofdiagnosis and intensity oftreatment The reviewing physicians identified hospitalizations that increase, the DRG payment rises faster than the cost of omitted medically indicated services and diagnoses providing medically indicated services. Background Classification ofDiseases 9th Revision, Clinical Modification (ICD-9-CM) numeric codes (Public Since October 1, 1983, Medicare has used a Health Service and Health Care Financing prospective payment system (PPS) to pay hospitals for Administration, 1980). The fiscal intermediary groups inpatient care, as required by the Social Security the ICD-9-CM codes to the proper DRG, converts the Amendments of 1983. Each discharge's diagnoses and corresponding relative weight to a dollar amount (with procedures "group" it to one of 477 diagnosis-related certain minor adjustments for hospital-specific factors), groups (DRGs). The Health Care Financing and pays the hospital (Averill et al., 1986). Administration (HCFA) pays the hospital a fixed Omission of medically indicated procedures could amount representing the average cost for that DRG's cause diagnostic uncertainty and may therefore produce discharges (Code ofFederal Regulations, 1988). The vague ICD-9-CM codes (e.g., the classic weak, tired, hospital retains surpluses from discharges that cost it and dizzy).
    [Show full text]
  • Using Vectorcardiography in Cardiac Resynchronization Therapy
    Using Vectorcardiography In Cardiac Resynchronization Therapy By L.Lindeboom BMTE 10.19 Report Internship Catharina Hospital Eindhoven Eindhoven University of Technology Supervisors Dr. Ir. M. van ‘t Veer Dr. B.M. van Gelder Dr. Ir. M.C.M. Rutten Prof. Dr. N.H.J. Pijls 1 Abstract (English) The conductive system of the heart may be affected by a heart disease due to direct damage of the Purkinje bundle branches or by a changed geometry in a dilated heart. As a result the electrical activation impulse will no longer travel across the preferred pathway and a loss of ventricular synchrony, prolonged ventricular depolarization and a corresponding drop in the cardiac output is observed. During cardiac resynchronization therapy (CRT) a biventricular pacemaker is implanted, which is used to resynchronise the contraction between different parts of the myocardium. Optimize pacing lead placement and CRT device programming, is important to maximize the benefit for the selected patients. The use of vectorcardiography (VCG) for CRT optimization is investigated. In current clinical practice a 12-lead electrocardiogram (ECG) is used to measure the electric cardiac activity of a patient. Each cell in the heart can be represented as an electrical dipole with differing direction during a heartbeat. A collection of all cellular dipoles will result in a single dipole, the cardiac electrical vector. Spatial visualization of the intrinsically three- dimensional phenomena, using VCG, might allow for an improved interpretation of the electric cardiac activity as compared to the one dimensional projections of a scalar ECG. The VCG loops of one healthy subject and two subjects with a left bundle branch block (LBBB) and two subjects with a right bundle branch block (RBBB) are qualitatively described.
    [Show full text]
  • Mcfee and Parungao Orthogonal Lead Vectorcardiography in Normal Dogs C
    Iowa State University Capstones, Theses and Retrospective Theses and Dissertations Dissertations 1-1-1972 McFee and Parungao orthogonal lead vectorcardiography in normal dogs C. B. Chastain Iowa State University Follow this and additional works at: https://lib.dr.iastate.edu/rtd Recommended Citation Chastain, C. B., "McFee and Parungao orthogonal lead vectorcardiography in normal dogs" (1972). Retrospective Theses and Dissertations. 17945. https://lib.dr.iastate.edu/rtd/17945 This Thesis is brought to you for free and open access by the Iowa State University Capstones, Theses and Dissertations at Iowa State University Digital Repository. It has been accepted for inclusion in Retrospective Theses and Dissertations by an authorized administrator of Iowa State University Digital Repository. For more information, please contact [email protected]. McFee and Parungao orthogonal lead vectorcardiography in normal dogs by Claud Blankenhorn Chastain A Thesis Submitted to the Graduate Faculty in Partial Fulfillment of The Requirements for the Degree of MASTER OF SCIENCE Major: Veterinary Clinical Sci ences Appr oved: Signatures have been redacted for privacy Iowa State University Ame s, Iowa 1972 ~ 1?C&R3 - ~­ l - I . ii ~r:,1 V J/- ;/; ~ (; . 5 .:< TABLE OF CONTENTS Page INTRODUCTION AND OBJECTIVES 1 LITERATURE EVALUATION 3 Evolution of Vectorcardiology 3 Comparison of Lead Systems 9 Normal Human Vectorcardiograms 10 Clinical Application 13 Vectorcardiography in the Canine 15 MATERIALS AND METHODS 19 Selection of Subjects and Recording Method 19 Storage and Reproduction of the QRS Loop 21 Evaluation of the QRS Loop 24 RESULTS 26 Magnitude and Orientation of Vectors 26 Statistical Analysis 28 DISCUSSION 29 SUMMARY AND CONCLUSIONS 36 LITERATURE CITED 39 ACKNOWLEDGMENTS 51 APPENDIX 52 1 INTRODUCTION AND OBJECTIVES I Vectorcardiography is a measurement of the direction, magnitude and orientation of the mean instantaneous voltage distributions of the heart.
    [Show full text]
  • Acute Coronary Syndrome
    Technology Assessment Systematic Review of ECG-based Signal Analysis Technologies for Evaluating Patients With Acute Coronary Syndrome Technology Assessment Program Prepared for: Agency for Healthcare Research and Quality October 2011 540 Gaither Road Rockville, Maryland 20850 Systematic Review of ECG-based Signal Analysis Technologies for Evaluating Patients With Acute Coronary Syndrome Technology Assessment Report Project ID: CRDD0311 October 2011 Duke Evidence-based Practice Center Remy R. Coeytaux, M.D., Ph.D. Philip J. Leisy, B.S. Galen S. Wagner, M.D. Amanda J. McBroom, Ph.D. Cynthia L. Green, Ph.D. Liz Wing, M.A. R. Julian Irvine, M.C.M. Gillian D. Sanders, Ph.D. DRAFT – Not for citation or dissemination This draft technology assessment is distributed solely for the purpose of peer review and/or discussion at the MedCAC meeting. It has not been otherwise disseminated by AHRQ. It does not represent and should not be construed to represent an AHRQ determination or policy. This report is based on research conducted by the Duke Evidence-based Practice Center under contract to the Agency for Healthcare Research and Quality (AHRQ), Rockville, MD (Contract No. HHSA 290-2007-10066 I). The findings and conclusions in this document are those of the authors, who are responsible for its contents. The findings and conclusions do not necessarily represent the views of AHRQ. Therefore, no statement in this report should be construed as an official position of the Agency for Healthcare Research and Quality or of the U.S. Department of Health and Human Services. None of the investigators has any affiliations or financial involvement related to the material presented in this report.
    [Show full text]
  • Proposed In-Training Electrocardiogram Interpretation Competencies for Undergraduate and Postgraduate Trainees
    REVIEW Proposed In-Training Electrocardiogram Interpretation Competencies for Undergraduate and Postgraduate Trainees Pavel Antiperovitch, MD, BSc1, Wojciech Zareba, MD, PhD2, Jonathan S. Steinberg, MD2,3, Ljuba Bacharova, MD, DSc, MBA4, Larisa G. Tereshchenko, MD, PhD5, Jeronimo Farre, MD, PhD, FESC6, Kjell Nikus, MD, PhD7, Takanori Ikeda, MD, PhD8, Adrian Baranchuk, MD, FACC, FRCPC FCCS1*, on behalf of the International Society of Electrocardiology and the International Society of Holter and Noninvasive Electrocardiology 1Department of Medicine, Kingston General Hospital, Queen’s University, Kingston, Ontario, Canada; 2Department of Medicine, University of Roch- ester Medical Center, University of Rochester, Rochester, New York; 3Arrhythmia Center, Summit Medical Group, Short Hills, New Jersey; 4Interna- tional Laser Center, Bratislava, Slovakia; 5Knight Cardiovascular Institute, Oregon Health and Science University, Portland, Oregon; 6Department of Cardiology, Fundación Jiménez Díaz University Hospital, Universidad Autónoma de Madrid, Madrid, Spain; 7Heart Center, Tampere University Hospital, and Faculty of Medicine and Life Sciences, University of Tampere, Teiskontie, Finland; 8Department of Medicine, Toho University, Tokyo, Ota, Omorinishi, Japan. Despite its importance in everyday clinical practice, the trainees. Previous literature suggests that methods of ability of physicians to interpret electrocardiograms (ECGs) teaching ECG interpretation are less important and can is highly variable. ECG patterns are often misdiagnosed, be selected based on the available resources of each and electrocardiographic emergencies are frequently education program and student preference. The evidence missed, leading to adverse patient outcomes. Currently, clearly favors summative trainee evaluation methods, many medical education programs lack an organized which would facilitate learning and ensure that appropriate curriculum and competency assessment to ensure trainees competencies are acquired.
    [Show full text]
  • Feasibility of Non-Invasive Foetal Electrocardiography in a Twin Pregnancy Lore Noben1,2*, Michelle E
    Noben et al. BMC Pregnancy and Childbirth (2020) 20:215 https://doi.org/10.1186/s12884-020-02918-8 TECHNICAL ADVANCE Open Access Feasibility of non-invasive Foetal electrocardiography in a twin pregnancy Lore Noben1,2*, Michelle E. M. H. Westerhuis1,2, Judith O. E. H. van Laar1,2, René D. Kok3, S. Guid Oei1,2, Chris H. L. Peters4 and Rik Vullings5,2 Abstract Background: Twin pregnancy is associated with increased perinatal mortality. Close foetal monitoring is therefore warranted. Doppler Ultrasound cardiotocography is currently the only available method to monitor both individual foetuses. Unfortunately, the performance measures of this method are poor and erroneous monitoring of the same twin with both transducers may occur, leaving the second twin unmonitored. In this study we aimed to determine the feasibility of monitoring both foetuses simultaneously in twin gestation by means of non-invasive foetal electrocardiography (NI-fECG), using an electrode patch on the maternal abdomen. Methods: A NI-fECG recording was performed at 25 + 3 weeks of gestation on a multiparous woman pregnant with dichorionic diamniotic twins. An electrode patch consisting of eight adhesive electrodes was applied on the maternal abdomen, yielding six channels of bipolar electrophysiological measurements. The output was digitized and stored for offline processing. The recorded signals were preprocessed by suppression of high-frequency noise, baseline wander, and powerline interference. Secondly, the maternal ECG was subtracted and segmentation into individual ECG complexes was performed. Finally, ensemble averaging of these individual ECG complexes was performed to suppress interferences. Results: Six different recordings were obtained from each of the six recording channels.
    [Show full text]
  • 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations
    Prepublication Release Neonatal Life Support 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations Myra H. Wyckoff, MD, Chair; Gary M. Weiner, MD; On behalf of the Neonatal Life Support Collaborators DOI: 10.1542/peds.2020-038505C Journal: Pediatrics Article Type: Supplement Article Citation: Wyckoff MH, Weiner GM, et al. Neonatal Life Support 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. Pediatrics. 2020; doi: 10.1542/peds.2020-038505C This article has been copublished in Circulation. This is a prepublication version of an article that has undergone peer review and been accepted for publication but is not the final version of record. This paper may be cited using the DOI and date of access. This paper may contain information that has errors in facts, figures, and statements, and will be corrected in the final published version. The journal is providing an early version of this article to expedite access to this information. The American Academy of Pediatrics, the editors, and authors are not responsible for inaccurate information and data described in this version. ©2020 AmericanDownloaded Academy from www.aappublications.org/news of Pediatrics and American by guest on September Heart Association, 26, 2021 Inc. Neonatal Life Support 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations Myra H. Wyckoff, MD, Chair; Gary M. Weiner, MD; On behalf of the Neonatal Life Support Collaborators ABSTRACT: This 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations (CoSTR) for neonatal life support includes The full author list is available on page S214.
    [Show full text]
  • A New Subspecialty Within Emergency Medicine
    Emergency Cardiac Care – a new subspecialty within Emergency Medicine Prof V. Anantharaman Department of Emergency Medicine Singapore General Hospital Objectives • Heart disease is a common event and of concern to EM • Why have ECC as a defined sub-division • Types of cardiovascular issues relevant to EM • Fellowship • International networks Causes of Mortality – Singapore 2004 • Cancer 27.1% • Ischaemic Heart Disease 18.8% • Pneumonia 14.1% • Cerbrovascular Disease 9.8% • Accidents, Poisoning, Violence 6.5% • Other Heart Diseases 4.2% •COPD 3.1% Source: Singapore Health Facts, 2005 produced by Ministry of Health, Singapore Cardiac Arrest Statistics • # of AMI per annum 2,400 • # of OHCA per annum 1,000 • Survival rates (2004) 2.7% • # of IHCA per annum 2,600 • In-hospital survival rate 30.0% Cardiovascular Emergencies -- types • Acute Coronary Syndromes – Out-of-hospital – In-hospital – Chest Pain patients • Arrhythmias • Heart Failures • Cardiac Arrests • Thrombosis / Embolism • Hypertensive Emergencies • Cerebrovascular Emergencies Development of Cardiology • Invasive Cardiology • Nuclear Cardiology • Electro-physiology • Inpatient cardiology • Elective cardiology Where do cardiac emergencies occur? • Out – of – hospital – Residences – Public Places – GP clinics – Ambulances • Emergency Department • General non-cardiology wards Issues in Cardiac Emergencies • Morbidity – Slow recognition and unnecessary delay in emergency care results in poor functional cardiovascular status • Too many in the hospital staying too long – Expensive and
    [Show full text]
  • Detection of Myocardial Ischemia Due to Clinically Asymptomatic Coronary
    Journal of Electrocardiology 59 (2020) 100–105 Contents lists available at ScienceDirect Journal of Electrocardiology journal homepage: www.jecgonline.com Detection of myocardial ischemia due to clinically asymptomatic coronary artery stenosis at rest using supervised artificial intelligence- enabled vectorcardiography – A five-fold cross validation of accuracy☆ Till Braun a, Sotirios Spiliopoulos b, Charlotte Veltman a, Vera Hergesell b, Alexander Passow a,c, Gero Tenderich a,c, Martin Borggrefe d, Michael M. Koerner e,f,⁎ a Cardisio GmbH, The Squaire 12, D-60549 Frankfurt am Main, Germany b Department of Cardiac Surgery, University Heart Center Graz, Medical University Graz, Auenbruggerplatz 29, A-8036 Graz, Austria c Faculty of Medicine, University Bochum, Universitaetsstrasse 150, D-44801 Bochum, Germany d First Department of Medicine, University Medical Centre Mannheim (UMM), Faculty of Medicine Mannheim, University of Heidelberg, European Center for AngioScience (ECAS), and DZHK (Ger- man Center for Cardiovascular Research) partner site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim, Germany e Nazih Zuhdi Advanced Cardiac Care & Transplant Institute, Department of Medicine, Integris Baptist Medical Center, 3400 NW Expressway, Bldg C, Suite 300, Oklahoma City, OK 73162, USA f Department of Rural Health - Medicine/Cardiology, Oklahoma State University Center For Health Sciences, 1111 W 17th Street, Tulsa, OK 74107, USA article info abstract Background: Coronary artery disease (CAD) is a leading cause of death and disability. Conventional non-invasive Keywords: diagnostic modalities for the detection of stable CAD at rest are subject to significant limitations: low sensitivity, Cardisiography and personal expertise. We aimed to develop a reliable and time-cost efficient screening tool for the detection of Coronary artery disease coronary ischemia using machine learning.
    [Show full text]
  • The History of Vectorcardiography*
    Medical History, Supplement No. 5, 1985: 103-131 THE HISTORY OF VECTORCARDIOGRAPHY* by GEORGE E. BURCH** Vectorcardiography (VCG) is a part of electrocardiography (ECG). The vectorcardiogram displays the various complexes of the electrocardiogram, i.e. QRS, P and T complexes, in the form of "loops" which are determined from vectors representing successive instantaneous mean electric forces from the heart throughout an entire cardiac cycle. Since the heart is a three-dimensional structure, the electric forces from the heart during each heartbeat are oriented three-dimensionally and, therefore, can be represented by a time sequence ofvectors which display the magnitude and direction of these mean electric forces. Anyone who knows the fundamental and theoretical aspects of electrocardiography and knows clinical cardiology and employs electrocardiographs with high frequency response and good fidelity can visualize the detailed configuration of the vectorcardiogram from the electrocardiogram. The electrocardiogram displays the same information as the vectorcardiogram and even provides other information not readily available from the vectorcardiogram, especially temporal phenomena and disorders in cardiac rhythm. Nevertheless, vectorcardiography has developed as a result of the efforts of many investigators who were interested in the use of vector analysis of the cardiac electric potentials recorded from the surface of the body. Such investigations have contributed a great deal to a better understanding of electrocardiography and aspects of electrophysiology. Since the time sequence, magnitude, and spatial direction of the instantaneous mean vectors are determined by the order of depolarization and repolarization of the atria and ventricles which, in turn, are affected by the clinical state of the myocardium, it was considered that the spatial vectorcardiogram could be useful in learning more about the electrophysiology of the heart in normal and diseased states.
    [Show full text]
  • Non-Invasive Fetal Monitoring
    sensors Article Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms Radek Martinek 1,*, Radana Kahankova 1, Homer Nazeran 2, Jaromir Konecny 1, Janusz Jezewski 3, Petr Janku 4, Petr Bilik 1, Jan Zidek 1, Jan Nedoma 5 and Marcel Fajkus 5 1 Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic; [email protected] (R.K.); [email protected] (J.K.); [email protected] (P.B.); [email protected] (J.Z.) 2 Department of Electrical and Computer Engineering, University of Texas El Paso, 500 W University Ave, El Paso, TX 79968, USA; [email protected] 3 Institute of Medical Technology and Equipment ITAM, 118 Roosevelt Str., 41-800 Zabrze, Poland; [email protected] 4 Department of Obstetrics and Gynecology, Masaryk University and University Hospital Brno, Jihlavska 20, 625 00 Brno, Czech Republic; [email protected] 5 Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic; [email protected] (J.N.); [email protected] (M.F.) * Correspondence: [email protected]; Tel.: +420-597-325-995 Academic Editor: Wan-Young Chung Received: 24 March 2017; Accepted: 12 May 2017; Published: 19 May 2017 Abstract: This paper is focused on the design, implementation and verification of a novel method for the optimization of the control parameters (such as step size m and filter order N) of LMS and RLS adaptive filters used for noninvasive fetal monitoring.
    [Show full text]
  • Screening for Cardiovascular Disease Risk with Electrocardiography: an Evidence Review for the U.S
    Evidence Synthesis Number 163 Screening for Cardiovascular Disease Risk With Electrocardiography: An Evidence Review for the U.S. Preventive Services Task Force Pre pare d for: Agency for Healthcare Research and Quality U.S. Department of Health and Human Services 5600 Fishers Lane Rockville, MD 20857 www.ahrq.gov Contract No. HHSA-290-2015-00011-I, Task Orde r No. 5 Prepared by: RTI International–University of North Carolina at Chapel Hill Evidence-based Practice Center Research Triangle Park, NC Investigators: Daniel E. Jonas, MD, MPH Shivani Reddy, MD, MSc Jennifer Cook Middleton, PhD Colleen Barclay, MPH Joshua Green, BA Claire Baker Gary Asher, MD, MPH AHRQ Publication No. 17-05235-EF-1 June 2018 This report is based on research conducted by the RTI International–University of North Carolina at Chapel Hill Evidence-based Practice Center (EPC) under contract to the Agency for Healthcare Research and Quality (AHRQ), Rockville, MD (Contract No. HHSA-290-2015- 00011-I, Task Order No. 5). The findings and conclusions in this document are those of the authors, who are responsible for its contents, and do not necessarily represent the views of AHRQ. Therefore, no statement in this report should be construed as an official position of AHRQ or of the U.S. Department of Health and Human Services. The information in this report is intended to help health care decisionmakers—patients and clinicians, health system leaders, and policymakers, among others—make well-informed decisions and thereby improve the quality of health care services. This report is not intended to be a substitute for the application of clinical judgment.
    [Show full text]