BAC-9300 Series Bacnet Unitary Controllers (B-AAC)

Total Page:16

File Type:pdf, Size:1020Kb

BAC-9300 Series Bacnet Unitary Controllers (B-AAC) BAC-9300 Series BACnet Unitary Controllers (B-AAC) DESCRIPTION (BAC-9301C with MS/TP KMC Conquest™ BAC-9300 series controllers are designed Shown) to operate unitary and terminal equipment. The integrated alarming, scheduling, and trending enable these BACnet Advanced Application Controllers to be powerful edge devices for the modern smart building ecosystem. The factory-supplied programming covers common unitary applications. The controllers feature simple, menu-driven setup choices using an STE-9000 series digital sensor, which can be installed permanently as the room sensor or used temporarily as a technician’s service tool. Alternately, quick configuration of controller properties can be done using NFC (Near Field Communication) from a smart MCConquestTM phone, tablet, or computer (using KMC Connect Lite™ app) while Automation ardware the controller is unpowered. The Ethernet-enabled BAC-93x1CE models can also be configured by connecting an HTML5-compatible web browser to the built-in configuration web pages. To meet the most demanding building automation custom APPLICATIONS requirements, these controllers are also fully programmable. Custom configuration and programming, with wizards for Can be used with the following types of unitary equipment: application programming selection/configuration, are enabled • Air handling units (AHU) by KMC Connect™ software and the KMC Converge™ module for • Chilled beams Niagara Workbench. • Constant air volume (CAV) with external actuator • Fan coil units (FCU) KMC Converge and TotalControl™ software additionally provide • Heat pump units (HPU) the capability of creating custom graphical web pages (hosted • Roof top units (RTU) on a remote web server) to use as a custom user-interface for • Unit ventilators the controllers. • Variable air volume (VAV) with external actuator (Some applications require custom programming. See also MODELS Sample Installation on page 6.) FEATURES APPLICATIONS INPUTS OUTPUTS MODEL Air Pressure Real Time Ethernet MS/TP Sensor (Input) Clock (RTC) Port Port 1 opt. air pressure 4 BAC-9301 RTU, HPU, FCU, sensor and 8 (total) 10 total: AHU, and unit standard: 4 4 BAC-9301C • 6 triacs ventilator • 2 analog (temp. (binary) sensor port) 4 4 BAC-9301CE • 4 universal • 6 universal (software VAV/CAV (with inputs (software 4 4 BAC-9311 configurable external tri-state configurable as as analog or BAC-9311C actuator), RTU/ analog, binary, 4 4 4 binary) HPU static pressure or accumulator monitoring/control on terminals) 4 4 4 BAC-9311CE KMC Controls, 19476 Industrial Drive, New Paris, IN 46553 / 877-444-5622 / Fax: 574-831-5252 / www.kmccontrols.com SPECIFICATIONS Room Output Power Sensor Port Terminals Terminals A E Power/Status (Optional) LED MS/TP Status LED, B Network F Bulbs, EOL C Switch, and Terminals (Optional) Differential Air NFC Input Pressure D Target Terminals Port DIMENSIONS (Optional) Ethernet TERMINAL COLOR CODE Ports (Changed A 6.744 inches 171 mm D 6.000 inches 152 mm Black 24 VAC/VDC Power from One to Two B 5.500 inches 140 mm E 1.500 inches 38 mm in 2016) Gray MS/TP Communications C 5.000 inches 127 mm F 6.279 inches 159 mm Green Inputs and Outputs Inputs and Outputs Outputs, Universal (4 on Terminal Blocks) Universal outputs Configurable as an analog (0 ot 12 Inputs, Universal (6 on Terminal Blocks) VDC) or binary object (0 or 12 VDC, Universal inputs Configurable as analog, binary, or on/off) accumulator objects Power/protection Each short-circuit protected universal Termination 1K and 10K ohm sensors, 0–12 VDC, output capable of driving up to 100 or 0–20 mA (without need for an mA (at 0–12 VDC) or 100 mA total for external resistor) all outputs Resolution 16-bit analog-to-digital conversion Resolution 12-bit digital-to-analog conversion Protection Overvoltage protection (24 VAC, Wire size 12–24 AWG, copper, in removable continuous) screw terminal blocks Wire size 12–24 AWG, copper, in removable Outputs, Triac (6 Binary) screw terminal blocks Triac outputs Optically isolated zero-crossing triac Input, Dedicated Room Sensor Port output configured as a binary object Connector Modular connector for STE-9xx1 Power Maximum switching 24 VAC at 1.0 A series digital wall sensors or STE- for each output; maximum total for 6010/6014/6017 analog temperature controller is 3.0 A sensors Wire size 12–24 AWG, copper, in removable Cable Uses standard Ethernet patch cable screw terminal blocks up to 150 feet (45 meters) Input, Integrated Air Pressure Sensor (BAC-9311) D pressure range 0 to 2" wc (0 to 500 Pa) Sensor accuracy ±4.5% of the reading or (when near zero) 0.0008" wc (0.2 Pa), whichever is greater (@ 25° C); internally line- arized and temperature compensated Connections Barbed for 1/4 inch FR (Flame Retard- ant) tubing 2 Communication Ports Configurability MS/TP (optional) One EIA-485 port (removable terminal block) for BACnet MS/TP, operating OBJECTS* MAXIMUM # at 9.6, 19.2, 38.4, 57.6, 76.8, or 115.2 Inputs and Outputs kilobaud; max. length of up to 4,000 8 for 9 for feet (1,200 meters) of 18 AWG shield- Analog, binary, or accumulator input ed twisted-pair, no more than 51 pf/ft BAC-9301 BAC-9311 (167 pf/m); use repeaters for longer Analog or binary output 10 distances Values Ethernet (optional) On “E” models only, two 10/100BaseT Analog value 120 Ethernet connectors for BACnet IP, Foreign Device, and Ethernet 802.3 Binary value 80 (ISO 8802-3); segmentation support- Multi-state value 40 ed; up to 328 ft (100 m) between controllers (using T568B Category 5 Program and Control or better cable) Program (Control Basic) 10 NFC NFC (Near Field Communication) up PID loop 10 to 1 inch (2.54 cm) from the top of the enclosure Schedules Room sensor Modular STE connection jack for Schedule 2 STE-9000 series digital sensors and Calendar 1 STE-6010/6014/6017 analog sensors Logs Auxiliary One serial port with mini Type B con- nector (reserved for future use) Trend log 20 Trend log multiple (must be created) 4 (default 0) Alarms and Events Notification class 5 Event enrollment 40 Tables Input tables 20 Control Basic tables 20 *Configuration allows creation and deletion of objects (maxi- mum number of objects shown). The number and configuration of default objects depends on the selected application. For lists of default objects, see the KMC Conquest Controller Application Guide. See also the PIC statement for all supported BACnet objects. 3 Configuring, Programming, and Designing Indicators and Isolation LED indicators Power/status and MS/TP communi- SETUP PROCESS KMC CONTROLS cation or Ethernet status Config- Programming Web Page TOOL MS/TP bulbs One network bulb assembly indicates uration (Control Basic) Graphics* reversed polarity and isolates circuit 4 Conquest NetSensor Switch EOL (end of line) for MS/TP Internal configuration 4 web pages in Conquest Installation Ethernet “E” models** KMC Connect Lite™ (NFC) Power 4 app*** Supply voltage 24 VAC (50/60 Hz) or 24 VDC; –15%, 4 4 KMC Connect™ software +20%; Class 2 only; non-supervised (all circuits, including supply voltage, 4**** 4**** 4 TotalControl™ software are power limited circuits) ™ Required power 8 VA, plus external loads 4 4 KMC Converge module for Niagara WorkBench Wire size 12–24 AWG, copper, in a removable screw terminal block KMC Converge GFX 4 module for Niagara Enclosure and Mounting WorkBench Weight 14 ounces (0.4 kg) *Custom graphical user-interface web pages can be hosted on a Case material Green and black flame retardant remote web server, but not in the controller. plastic **Conquest Ethernet-enabled “E” models with the latest firmware can be configured with an HTML5 compatible web browser from Mounting Direct mounting to panels or on DIN pages served from within the controller. For information, see the rails Conquest Ethernet Controller Configuration Web Pages Applica- tion Guide. Environmental Limits ***Near Field Communication via enabled smart phone or tablet Operating 32 to 120° F (0 to 49° C) running the KMC Connect Lite app. Shipping –40 to 160° F (–40 to 71° C) ****Full configuration and programming of KMC Conquest con- trollers is supported starting with TotalControl ver. 4.0. Humidity 0 to 95% relative humidity (non-condensing) Warranty, Protocol, and Approvals Hardware Features Warranty Processor, Memory, and Clock KMC Limited Warranty 5 years (from mfg. date code) Processor 32-bit ARM® Cortex-M4 Memory Programs and configuration parame- BACnet Protocol ters are stored in nonvolatile memory; Standard Meets or exceeds the specifications auto restart on power failure in ANSI/ASHRAE BACnet Standard RTC Real time clock with (capacitor) pow- 135-2010 for Advanced Application er backup for 72 hours (“C” model Controllers only) for network time synchroniza- Type BTL-certified as a B-AAC controller tion or full stand-alone operation type 4 Regulatory Approvals Miscellaneous Hardware UL UL 916 Energy Management Equip- HCO-1103 Steel control enclosure with DIN rail ment listed mounting, 10 x 7.5 x 2.5 inches (257 UL 864 Smoke Control Equipment x 67 x 193 mm) listed (UUKL), 10th edition—for HCO-1035 Steel control enclosure, 20 x 24 x 6 smoke control applications, see inches (508 x 610 x 152 mm)* Smoke Control Manual for KMC HCO-1036 Steel control enclosure, 24 x 36 x 6 Conquest Systems, P/N 000-035-18) inches (610 x 914 x 152 mm)* BTL BACnet Testing Laboratory listed SP-001 Screwdriver (KMC branded) with a as Advanced Application Controller hex end (for NetSensor cover screws) (B-AAC) and a flat blade end (for controller CE CE compliant terminals) RoHS 2 RoHS 2 compliant HPO-9901 Controller replacement parts kit with FCC FCC Class A, Part 15, Subpart B and terminal blocks (1 gray, 1 black, 2 complies with Canadian ICES-003 green 3-terminal, 4 green 4-terminal, Class A* 2 green 5-terminal, 2 green 6-termi- nal) and DIN clips (2 small for router *This device complies with part 15 of the FCC Rules.
Recommended publications
  • Zone Control with Variable Air Volume Controls (VAV)- KMC Controls
    4/9/2014 Zone control with Variable Air Volume controls (VAV)- KMC Controls product search / > Solutions Zone control with Variable Air Volume controls (VAV) The goal of any HVAC system is to maintain a temperature within a space or zone. When the space is large, such as an Answers & Education auditorium or open factory space, the HVAC system delivers tempered supply air based on a single setpoint and space temperature. However, when the system must maintain the comfort level in several zones the problem becomes more Like 28 people like this. complex. For example, an office area system must maintain a comfortable temperature based on multiple setpoints in individual rooms. This complex problem is often solved by installing a system of variable air volume controls on branch outlets. The simplest variable air volume control (VAV) system controls air from a single supply duct and varies the airflow to each zone or room based upon the temperature in the room. A VAV system consists of four basic parts: a thermostat, a precision actuator controlled damper, an airflow sensor, and a controller. When the thermostat senses the space temperature is at the temperature setpoint, the controller closes the damper until the airflow reaches a predefined lower limit. As the room temperature moves away from setpoint, the controller opens the damper until the airflow reaches a predefined upper limit. In a typical cooling application the temperature of the air supplied air to a VAV control is 55° Fahrenheit. If the room is at the temperature setpoint, the damper in the VAV closes to minimum airflow.
    [Show full text]
  • BAS Requirements for FDA-Regulated Environments Contents
    White Paper Series BAS Requirements for FDA-Regulated Environments Contents Challenges and Opportunities for Industries 1 Challenges and Opportunities for Industries Validated System Implementation 2 Title 21 CFR Part 11 (of the Code of Federal Regulations) describes FDA (Food and Drug Administration) guidelines on electronic records and signatures. It defines the criteria under which they are considered “to be trustworthy, reli- able, and generally equivalent to paper” (Title 21 CFR Part 11 Section 11.1 (a)). Determining “Impact” and “Boundaries” 4 In practice, Part 11 requires pharmaceutical manufacturers, medical device manufacturers, biotech companies, and other FDA regulated industries to implement controls (such as audits, system validations, audit trails, electronic BAS Options for Validation 6 signatures, and documentation for software and systems involved in process- ing data) that are required to be maintained by or in compliance with FDA predicate rules. (See the Glossary of Terms section for explanations of italicized Glossary of Terms 7 terms.) The FDA introduced Title 21 CFR Part 11 to promote usage of digital technology in the life sciences industry that would be compatible with the FDA’s responsi- More Information 9 bility to protect public health. This resulted in the need for updating industry processes and procedures that address compliance of “validated” systems. About KMC Controls 9 Page 1 Companies rarely welcome new government regulation of any kind, but the FDA created incentive and opportunity for companies to improve performance and efficiency. Operational improvements from upgraded Building Automation Systems (BAS) has been especially notable since consistent temperature and humidity within manufacturing facilities is often critically important for quality control in pharmaceutical production.
    [Show full text]
  • APPLICATION Guide for Flexstat
    FlexStat™ BACnet Programmable Thermostats DRAFT Application Guide NOTE: Watermark is on nonwritable DRAFT Watermark layer. Turn the Contents layer off or delete layer to remove from the final document. General Information (All Output Configurations) .................. 3 Sample Custom Applications ..........................................................................20 Overview and General Installation ...................................................................4 Adding a Remote Temperature Sensor to an Input ......................................20 Mounting Considerations .................................................................................4 Using Another Controller’s Sensors ............................................................21 Wiring Considerations ......................................................................................5 Displaying the Current Setpoint .................................................................22 Inputs and Outputs ..........................................................................................6 Displaying Outside Air Temperature ...........................................................23 Connecting Standard Inputs .........................................................................6 Displaying Other Objects ...........................................................................23 4–20 mA Current Input ................................................................................7 Mapping Analog Inputs or Outputs as Binary .............................................24
    [Show full text]
  • Green Building & Controls Glossary
    GREEN BUILDING & CONTROLS GLOSSARY kmccontrols.com Read First: Top Tips on Using this Glossary These tips are for optimizing your use of the Adobe Acrobat PDF version of this document. For the fastest finding of terms, click on the appropriate bookmarks and/or cross-references. Alternately, use Acro- bat’s search function to look up terms. Bookmarks, at the left of the screen, are hyperlinks to document pages. From any page in this document, you can use book- marks to jump to any section heading. To jump to a bookmarked section, point to the bookmark name, and when the arrow be- comes a pointing hand, click on the name. Cross-references (in blue italics) at the end of glossary entries are hyperlinked to those topics. Click on the cross-reference to go instantly to that page. If printing pages, select from the print dialog box (Acrobat 7 and later) Page scal- ing > Multiple pages per sheet, Pages per sheet > 4. (Auto-Rotate Pages should also be checked.) This minimizes the number of sheets printed, and it still prints at nearly full size. (A commercially printed booklet version can also be ordered from KMC Controls.) 2 Green Building & Controls Glossary 19476 Industrial Drive New Paris, IN 46553, U.S.A. 877.444.5622 (574.831.5250) www.kmccontrols.com [email protected] KMC Controls,® KMDigital,® CommTalk,® ControlSet ®, Incontrol,® NetView,® NetSensor,® WinControl,® and “building your comfort zone®” are all registered trademarks of KMC Controls. KMC Conquest,™ KMC Commander,™ KMC CommanderBX™, KMC Con- nect,™ KMC Connect Lite,™ KMC Converge,™ FlexStat,™ TotalCon- trol,™ WebLite,™ LANLite,™ FirstWatch,™ BACstage,™ FullBAC,™ and BUILDING GENIUSES™ are all trademarks of KMC Controls.
    [Show full text]
  • OPERATION GUIDE for Flexstat
    FlexStat™ BACnet Programmable Thermostats Operation Guide Contents Overview ................................................................3 (Advanced) CO2 Sensor (and DCV) ................11 Applications and Installation ...................................3 CO2 Sensor Setup and Information ...........11 Operation (Basic) ....................................................4 DCV (Demand Control Ventilation) Setup .11 Navigation ..........................................................4 (Advanced) Communications (BACnet) ..........14 Room Temp. Setpoint Adjustment .......................4 (Advanced) Date/Time ...................................16 H/C, Fan, Occupancy, and Override ...................4 (Advanced) BACnet Device Properties ...........17 Main Menu and Settings ......................................4 (Advanced) Inputs ..........................................17 Display Options ..................................................5 (Advanced) Temp. Setpoint Limits ..................17 Configuration (Setup) ..............................................6 (Advanced) PID Loop Configuration ..............18 Main Menu Overview .........................................6 (Advanced) Restart/Restore ...........................18 About the FlexStat ...............................................6 (Advanced) Security Levels and Passwords .....18 Advanced Menu ..................................................7 (Advanced) Test ..............................................19 (Advanced) Application and Additional Setup ..7 (Advanced) Trend
    [Show full text]
  • CREATING and DELIVERING Complete Building Automation Solutions Who Is KMC Controls? Our Mission Is Building Your Comfort Zone
    CREATING and DELIVERING Complete Building Automation Solutions Who is KMC Controls? Our Mission is Building Your Comfort Zone Our corporate theme reflects our commitment to you: “building your comfort zone.” Through innovative product development, expertise in manufacturing, excellence in distribution, and responsiveness in customer support, we deliver effective, market- driven solutions for building control and automation. Since 1969, KMC Controls has been building and delivering innovative solutions for intelligent building automation and HVAC controls. As a financially solid family-owned-and-operated entity, KMC Controls delivers a responsiveness and flexibility not found in larger companies and corporate mergers. Brilliant Manufacturing through Innovation KMC Controls’ unique DNA traces back to the ingenuity and drive of company founder Ken Kreuter, a brilliant engineer who patented a large number of HVAC devices that are among the dozens currently held by the company. His family members are still active in various roles throughout the company. In addition to a culture of innovation, KMC has an ISO 9001:2000 registered quality system in place. We meet the highest quality standards and can still quickly make changes dictated by the needs of the market. Our quality and quick response have led to reliable production of a complete line of pneumatic, analog electronic, and digital controls. KMC is the only privately held, full-line controls manufacturer operating within the USA. Superb Customer Support Even the very best widgets would be worthless without proper support. Our Customer Service representatives excel at establishing personal relationships with their assigned customers. They know our product lines, have real-time inventory information at their fingertips, and can advise on product cross-reference information as well as all shipping options.
    [Show full text]
  • Installation, Operation, and Application Guide for Appstat™
    Installation, Operation, and Application Guide for AppStat™ BAC-4000 series controllers for Fan Coil Units, Roof Top Units, and Heat Pump Units. Revision D KMC Controls, Inc. ©2013, KMC Controls, Inc. NetSensor, WinControl, and the KMC logo are registered trademarks of KMC Controls, Inc. AppStat, BACstage, FlexStat, FullBAC, and TotalControl are trademarks of KMC Controls, Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of KMC Controls, Inc. Printed in U.S.A. The material in this manual is for information purposes only. The contents and the product it describes are subject to change without notice. KMC Controls, Inc. makes no representations or warranties with respect to this manual. In no event shall KMC Controls, Inc. be liable for any damages, direct or incidental, arising out of or related to the use of this manual. KMC Controls, Inc. P.O. Box 497 19476 Industrial Drive New Paris, IN 46553 U.S.A. TEL: 1.574.831.5250 FAX: 1.574.831.5252 E-mail: [email protected] 2 Revision D Installation, Operation, and Application Guide for AppStat Contents Contents Contents 3 Section 1: Introduction to the AppStat 7 Specifications 8 Installation accessories 12 AppStat model numbers 13 Safety considerations 16 Section 2: Installing the AppStat 17 Planning for motion sensing 17 Mounting the AppStat 18 Rough-in preparation 19 Installing the AppStat 19 Connecting inputs 20 Remote space
    [Show full text]
  • BAC-9000 Series Bacnet VAV Controller-Actuators (B-AAC)
    BAC-9000 Series BACnet VAV Controller-Actuators (B-AAC) DESCRIPTION (BAC-9001 with KMC Conquest™ BAC-9000 series controller-actuators are MS/TP Shown) designed to operate VAV (Variable Air Volume) terminal units. The integrated alarming, scheduling, and trending enable these BACnet Advanced Application Controllers to be powerful edge devices for the modern smart building ecosystem. With integrated actuators, internal air pressure sensors, and other powerful features, they are ideal for new installations and upgrades of less-efficient equipment. They easily mount to terminal boxes by securing a “V” clamp on the shaft and securing a single-screw anti-rotation bracket. The factory-supplied programming covers common VAV MCConquestTM Automation ardware applications. The controllers feature simple, menu-driven setup choices using an STE-9000 series digital sensor, which can be installed permanently as the room sensor or used temporarily as a technician’s service tool. Alternately, quick configuration of controller properties can be done using NFC (Near Field Communication) from a smart APPLICATIONS phone, tablet, or computer (using KMC Connect Lite™ app) while Application options include: the controller is unpowered. The Ethernet-enabled BAC-9001CE can also be configured by connecting an HTML5-compatible • Pressure independent or dependent VAV web browser to the built-in configuration web pages. • Cooling only and with changeover • Staged, modulated, floating, or time-proportional reheat For demanding building automation custom requirements, these • Series or parallel fan control controllers are also fully programmable. Custom configuration • Dual duct (with TSP-8003 actuators) and programming, with wizards for application programming • Supply/exhaust tracking (with TSP-8003 actuators) selection/configuration, are enabled by KMC Connect™ software • CAV (Constant Air Volume) and the KMC Converge™ module for Niagara Workbench.
    [Show full text]
  • Get Control of Your Green Building
    Get Control of Your Green Building And Earn LEED Certification Points in: • Energy and Atmosphere • Indoor Environmental Quality (Merry Lea Environmental Learning Center, Platinum LEED Certified) Green is good for the triple bottom line (people, planet, current generated by photovoltaic arrays and a wind and profit). Green buildings are good for occupants turbine (to get credit from the utility company), as well as (healthier and more comfortable working space), good other environmental conditions. for our environment (reduced resource depletion and higher sustainability—helps preserve the earth for future Whether your green building is small or large, KMC generations), and good for business (higher employee products provide powerful tools toward achieving points productivity, lower energy and life cycle costs, higher client for LEED certification in the two crucial categories of attraction/retention, higher resale value, and enhanced Indoor Environmental Quality and Energy and Atmosphere. public relations). In many government, school, hospital, hotel, office, and other commercial buildings, our controls have been Although any building may be built or remodeled with managing energy for decades—minimizing energy use various enhanced green characteristics, significant advan- while optimizing occupant comfort. Monitoring of air tages exist in obtaining building certification by one of temperature, humidity, pressure, CO2, and CO levels the “green” organizations, such as (among others) the U.S. provides for the controlling of condition levels, sounding Green Building Council’s LEED (Leadership in Energy and alarms, and recording trends. For energy metering and Environmental Design) Green Building Rating System.® A monitoring, we offer solutions that help provide data for building’s certification provides proof of its triple bottom line.
    [Show full text]
  • KMC Conquest™ Controller AIR DISTRIBUTION Application Guide
    KMC Conquest™ Controller AIR DISTRIBUTION Application Guide Contents GENERAL INFORMATION ....................................................................4 About KMC Conquest ...................................................................4 Specifications, Accessories, and Installation ...................................4 Video Tutorials ...........................................................................5 Submittal Sheets (Diagrams and Operation) ....................................5 Support .....................................................................................6 Important Notices .......................................................................6 Notes and Cautions .....................................................................6 Handling Precautions ..................................................................6 (STATUS) INDICATORS ......................................................................7 Indicators, Connections, and Status ...............................................7 Ready (Power/Status) LEDs (Green) ...............................................7 MS/TP LEDs (Amber) ...................................................................7 EIO LEDs (Green) ........................................................................8 Network Isolation Bulbs (HPO-0055) ..............................................8 Ethernet LEDs (Green and Amber) ..................................................8 CONNECTIONS (SENSORS, EQUIPMENT, NETWORKS) .............................9 Input Connections
    [Show full text]
  • Smoke Control Manual for KMC Conquest Systems
    Smoke Control Manual For KMC Conquest Systems SmokeKMC Controls, Control Manual 19476 Industrialfor KMC Conquest Drive, New Systems Paris, IN 46553 / 877.444.56221 / Fax: 574.831.5252 / www.kmccontrols.com000-035-18B Contents Important Notices ..............................................................................................................................4 Purpose............................................................................................................................................4 What is Smoke Control? ......................................................................................................................5 Smoke Control Systems ......................................................................................................................5 What is a Smoke Control System? ...................................................................................................5 UUKL Rating and UL 864 ................................................................................................................6 How to Implement ........................................................................................................................6 Dedicated and Non-Dedicated Equipment .........................................................................................6 HVAC System Smoke Control (Non-Dedicated Systems) Considerations ................................................6 Firefighter’s Smoke Control Station (FSCS) .............................................................................................7
    [Show full text]
  • Digital Designer's Guide
    Digital Designer’s Guide 000-035-07B SP-022B Important notices ©2010, KMC Controls, Inc. BACstage, FullBAC and TotalControl are trademarks of KMC Controls, Inc. WinControl XL Plus, NetSensor and the KMC logo are registered trademarks of KMC Controls, Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of KMC Controls, Inc. Printed in U.S.A. Disclaimer The material in this manual is for information purposes only. The contents and the product it describes are subject to change without notice. KMC Controls, Inc. makes no representations or warranties with respect to this manual. In no event shall KMC Controls, Inc. be liable for any damages, direct or incidental, arising out of or related to the use of this manual. KMC Controls P. O. B ox 4 97 19476 Industrial Drive New Paris, IN 46553 U.S.A. TEL: 1.574.831.5250 FAX: 1.574.831.5252 E-mail: [email protected] Digital Designer’s Guide Contents Part 1: DDC practices AN0504L Connecting inputs and outputs to KMC controllers............................................ 1-3 AN0604D Tips for connecting 24-volt power................................................................... 1-15 Part 2: Networking connectivity AN0903A Building Controls & Your Ethernet Network ...................................................... 2-3 AN0404A Planning BACnet networks................................................................................ 2-7 AN0704A Connecting EIA–485 network segments with fiber optic cables ....................... 2-31 Part 3: Job specific controllers AN0404B KMD-7001 and KMD-7051 VAV Controller...................................................... 3-3 AN0404C KMD–7002 and KMD–7052 VAV Controller................................................... 3-29 AN0905A KMD-7003 and KMD-7053 VAV Controller...................................................
    [Show full text]