BAC-9300 Series Bacnet Unitary Controllers (B-AAC)
Total Page:16
File Type:pdf, Size:1020Kb
BAC-9300 Series BACnet Unitary Controllers (B-AAC) DESCRIPTION (BAC-9301C with MS/TP KMC Conquest™ BAC-9300 series controllers are designed Shown) to operate unitary and terminal equipment. The integrated alarming, scheduling, and trending enable these BACnet Advanced Application Controllers to be powerful edge devices for the modern smart building ecosystem. The factory-supplied programming covers common unitary applications. The controllers feature simple, menu-driven setup choices using an STE-9000 series digital sensor, which can be installed permanently as the room sensor or used temporarily as a technician’s service tool. Alternately, quick configuration of controller properties can be done using NFC (Near Field Communication) from a smart MCConquestTM phone, tablet, or computer (using KMC Connect Lite™ app) while Automation ardware the controller is unpowered. The Ethernet-enabled BAC-93x1CE models can also be configured by connecting an HTML5-compatible web browser to the built-in configuration web pages. To meet the most demanding building automation custom APPLICATIONS requirements, these controllers are also fully programmable. Custom configuration and programming, with wizards for Can be used with the following types of unitary equipment: application programming selection/configuration, are enabled • Air handling units (AHU) by KMC Connect™ software and the KMC Converge™ module for • Chilled beams Niagara Workbench. • Constant air volume (CAV) with external actuator • Fan coil units (FCU) KMC Converge and TotalControl™ software additionally provide • Heat pump units (HPU) the capability of creating custom graphical web pages (hosted • Roof top units (RTU) on a remote web server) to use as a custom user-interface for • Unit ventilators the controllers. • Variable air volume (VAV) with external actuator (Some applications require custom programming. See also MODELS Sample Installation on page 6.) FEATURES APPLICATIONS INPUTS OUTPUTS MODEL Air Pressure Real Time Ethernet MS/TP Sensor (Input) Clock (RTC) Port Port 1 opt. air pressure 4 BAC-9301 RTU, HPU, FCU, sensor and 8 (total) 10 total: AHU, and unit standard: 4 4 BAC-9301C • 6 triacs ventilator • 2 analog (temp. (binary) sensor port) 4 4 BAC-9301CE • 4 universal • 6 universal (software VAV/CAV (with inputs (software 4 4 BAC-9311 configurable external tri-state configurable as as analog or BAC-9311C actuator), RTU/ analog, binary, 4 4 4 binary) HPU static pressure or accumulator monitoring/control on terminals) 4 4 4 BAC-9311CE KMC Controls, 19476 Industrial Drive, New Paris, IN 46553 / 877-444-5622 / Fax: 574-831-5252 / www.kmccontrols.com SPECIFICATIONS Room Output Power Sensor Port Terminals Terminals A E Power/Status (Optional) LED MS/TP Status LED, B Network F Bulbs, EOL C Switch, and Terminals (Optional) Differential Air NFC Input Pressure D Target Terminals Port DIMENSIONS (Optional) Ethernet TERMINAL COLOR CODE Ports (Changed A 6.744 inches 171 mm D 6.000 inches 152 mm Black 24 VAC/VDC Power from One to Two B 5.500 inches 140 mm E 1.500 inches 38 mm in 2016) Gray MS/TP Communications C 5.000 inches 127 mm F 6.279 inches 159 mm Green Inputs and Outputs Inputs and Outputs Outputs, Universal (4 on Terminal Blocks) Universal outputs Configurable as an analog (0 ot 12 Inputs, Universal (6 on Terminal Blocks) VDC) or binary object (0 or 12 VDC, Universal inputs Configurable as analog, binary, or on/off) accumulator objects Power/protection Each short-circuit protected universal Termination 1K and 10K ohm sensors, 0–12 VDC, output capable of driving up to 100 or 0–20 mA (without need for an mA (at 0–12 VDC) or 100 mA total for external resistor) all outputs Resolution 16-bit analog-to-digital conversion Resolution 12-bit digital-to-analog conversion Protection Overvoltage protection (24 VAC, Wire size 12–24 AWG, copper, in removable continuous) screw terminal blocks Wire size 12–24 AWG, copper, in removable Outputs, Triac (6 Binary) screw terminal blocks Triac outputs Optically isolated zero-crossing triac Input, Dedicated Room Sensor Port output configured as a binary object Connector Modular connector for STE-9xx1 Power Maximum switching 24 VAC at 1.0 A series digital wall sensors or STE- for each output; maximum total for 6010/6014/6017 analog temperature controller is 3.0 A sensors Wire size 12–24 AWG, copper, in removable Cable Uses standard Ethernet patch cable screw terminal blocks up to 150 feet (45 meters) Input, Integrated Air Pressure Sensor (BAC-9311) D pressure range 0 to 2" wc (0 to 500 Pa) Sensor accuracy ±4.5% of the reading or (when near zero) 0.0008" wc (0.2 Pa), whichever is greater (@ 25° C); internally line- arized and temperature compensated Connections Barbed for 1/4 inch FR (Flame Retard- ant) tubing 2 Communication Ports Configurability MS/TP (optional) One EIA-485 port (removable terminal block) for BACnet MS/TP, operating OBJECTS* MAXIMUM # at 9.6, 19.2, 38.4, 57.6, 76.8, or 115.2 Inputs and Outputs kilobaud; max. length of up to 4,000 8 for 9 for feet (1,200 meters) of 18 AWG shield- Analog, binary, or accumulator input ed twisted-pair, no more than 51 pf/ft BAC-9301 BAC-9311 (167 pf/m); use repeaters for longer Analog or binary output 10 distances Values Ethernet (optional) On “E” models only, two 10/100BaseT Analog value 120 Ethernet connectors for BACnet IP, Foreign Device, and Ethernet 802.3 Binary value 80 (ISO 8802-3); segmentation support- Multi-state value 40 ed; up to 328 ft (100 m) between controllers (using T568B Category 5 Program and Control or better cable) Program (Control Basic) 10 NFC NFC (Near Field Communication) up PID loop 10 to 1 inch (2.54 cm) from the top of the enclosure Schedules Room sensor Modular STE connection jack for Schedule 2 STE-9000 series digital sensors and Calendar 1 STE-6010/6014/6017 analog sensors Logs Auxiliary One serial port with mini Type B con- nector (reserved for future use) Trend log 20 Trend log multiple (must be created) 4 (default 0) Alarms and Events Notification class 5 Event enrollment 40 Tables Input tables 20 Control Basic tables 20 *Configuration allows creation and deletion of objects (maxi- mum number of objects shown). The number and configuration of default objects depends on the selected application. For lists of default objects, see the KMC Conquest Controller Application Guide. See also the PIC statement for all supported BACnet objects. 3 Configuring, Programming, and Designing Indicators and Isolation LED indicators Power/status and MS/TP communi- SETUP PROCESS KMC CONTROLS cation or Ethernet status Config- Programming Web Page TOOL MS/TP bulbs One network bulb assembly indicates uration (Control Basic) Graphics* reversed polarity and isolates circuit 4 Conquest NetSensor Switch EOL (end of line) for MS/TP Internal configuration 4 web pages in Conquest Installation Ethernet “E” models** KMC Connect Lite™ (NFC) Power 4 app*** Supply voltage 24 VAC (50/60 Hz) or 24 VDC; –15%, 4 4 KMC Connect™ software +20%; Class 2 only; non-supervised (all circuits, including supply voltage, 4**** 4**** 4 TotalControl™ software are power limited circuits) ™ Required power 8 VA, plus external loads 4 4 KMC Converge module for Niagara WorkBench Wire size 12–24 AWG, copper, in a removable screw terminal block KMC Converge GFX 4 module for Niagara Enclosure and Mounting WorkBench Weight 14 ounces (0.4 kg) *Custom graphical user-interface web pages can be hosted on a Case material Green and black flame retardant remote web server, but not in the controller. plastic **Conquest Ethernet-enabled “E” models with the latest firmware can be configured with an HTML5 compatible web browser from Mounting Direct mounting to panels or on DIN pages served from within the controller. For information, see the rails Conquest Ethernet Controller Configuration Web Pages Applica- tion Guide. Environmental Limits ***Near Field Communication via enabled smart phone or tablet Operating 32 to 120° F (0 to 49° C) running the KMC Connect Lite app. Shipping –40 to 160° F (–40 to 71° C) ****Full configuration and programming of KMC Conquest con- trollers is supported starting with TotalControl ver. 4.0. Humidity 0 to 95% relative humidity (non-condensing) Warranty, Protocol, and Approvals Hardware Features Warranty Processor, Memory, and Clock KMC Limited Warranty 5 years (from mfg. date code) Processor 32-bit ARM® Cortex-M4 Memory Programs and configuration parame- BACnet Protocol ters are stored in nonvolatile memory; Standard Meets or exceeds the specifications auto restart on power failure in ANSI/ASHRAE BACnet Standard RTC Real time clock with (capacitor) pow- 135-2010 for Advanced Application er backup for 72 hours (“C” model Controllers only) for network time synchroniza- Type BTL-certified as a B-AAC controller tion or full stand-alone operation type 4 Regulatory Approvals Miscellaneous Hardware UL UL 916 Energy Management Equip- HCO-1103 Steel control enclosure with DIN rail ment listed mounting, 10 x 7.5 x 2.5 inches (257 UL 864 Smoke Control Equipment x 67 x 193 mm) listed (UUKL), 10th edition—for HCO-1035 Steel control enclosure, 20 x 24 x 6 smoke control applications, see inches (508 x 610 x 152 mm)* Smoke Control Manual for KMC HCO-1036 Steel control enclosure, 24 x 36 x 6 Conquest Systems, P/N 000-035-18) inches (610 x 914 x 152 mm)* BTL BACnet Testing Laboratory listed SP-001 Screwdriver (KMC branded) with a as Advanced Application Controller hex end (for NetSensor cover screws) (B-AAC) and a flat blade end (for controller CE CE compliant terminals) RoHS 2 RoHS 2 compliant HPO-9901 Controller replacement parts kit with FCC FCC Class A, Part 15, Subpart B and terminal blocks (1 gray, 1 black, 2 complies with Canadian ICES-003 green 3-terminal, 4 green 4-terminal, Class A* 2 green 5-terminal, 2 green 6-termi- nal) and DIN clips (2 small for router *This device complies with part 15 of the FCC Rules.