Eco-Design of CH Boilers

Total Page:16

File Type:pdf, Size:1020Kb

Eco-Design of CH Boilers Task 4 - final Preparatory Study on Eco-design of CH Boilers Task 4 Report (FINAL) Technical Analysis (incl. System Model) René Kemna Martijn van Elburg William Li Rob van Holsteijn Delft, 30 September 2007 VHK Van Holsteijn en Kemna BV, Elektronicaweg 14, NL-2628 XG Delft, Netherlands Report prepared for: European Commission, DG TREN, Unit D3, Rue de la Loi 200, 1100 Brussels, Belgium Technical officer: Matthew Kestner DISCLAIMER & IMPORTANT NOTE The authors accept no liability for any material or immaterial direct or indirect damage resulting from the use of this report or its content. This report contains the results of research by the authors and any opinions in this report are to be seen as strictly theirs. The report is not to be perceived as the opinion of the European Commission, nor of any of the expertsor stakeholders consulted. Eco-design Boilers, Task 4, Final | 30 September 2007 | VHK for European Commission II CONTENTS page 1 INTRODUCTION .............................................................................. 1 1.1 Scope .....................................................................................................................................1 1.2 Approach.............................................................................................................................. 2 1.3 Report structure................................................................................................................... 3 2 BASIC ENERGY AND MASS BALANCE ..................................................5 2.1 Introduction......................................................................................................................... 5 2.2 Global chemical reaction ..................................................................................................... 6 2.3 Mass balance........................................................................................................................ 6 2.3.1 Stoichiometric volume balance .............................................................................. 6 2.3.2 Air factor/ lambda .................................................................................................. 6 2.3.3 Humidity of combustion air ................................................................................... 7 2.3.4 Influence of emissions ............................................................................................ 7 2.3.5 Converting volume into mass balance.................................................................... 9 2.4 Energy balance combustion............................................................................................... 10 2.4.1 Introduction.......................................................................................................... 10 2.4.2 Combustion heat Qrad + Qconv ................................................................................. 11 2.4.3 Latent condensation heat Qlatent.............................................................................13 2.4.4 Heat loss in excess combustion air Qxsair ...............................................................15 2.4.5 Fuel loss Qfuel-loss .....................................................................................................15 2.5 Energy balance burner........................................................................................................17 2.6 Heat balance primary heat exchanger ............................................................................... 22 2.6.1 Introduction.......................................................................................................... 22 2.6.2 Flue gas losses in on-mode ................................................................................... 24 2.6.3 Losses through the generator envelope in on-mode ............................................ 26 2.6.4 Standing losses in off-mode.................................................................................. 27 2.6.5 Start-stop losses.....................................................................................................31 2.6.6 Primary heat exchanger: Flow diagram ............................................................... 33 2.7 Heat balance secondary and tertiary heat exchanger........................................................ 34 2.7.1 Secondary heat exchanger .................................................................................... 34 2.7.2 Tertiary heat exchanger ........................................................................................ 35 2.8 Heat balance with storage facilities ................................................................................... 36 2.9 Auxiliary energy ................................................................................................................. 37 2.10 Total energy balance .......................................................................................................... 38 3 EMISSIONS ................................................................................. 40 3.1 Introduction....................................................................................................................... 40 3.2 Environmental impact ........................................................................................................41 3.3 Emissions grouped by origin ............................................................................................. 43 3.4 Low non-CO2 Carbon Emission......................................................................................... 44 3.4.1 Formation ............................................................................................................. 44 3.5 Low NOx technology........................................................................................................... 45 3.5.1 Introduction.......................................................................................................... 45 3.5.2 Formation of NOx.................................................................................................. 46 3.6 Principles of Primary Control of NOx Emissions............................................................... 47 3.6.1 Modification of Fuel/Air Delivery-Burner System............................................... 48 3.6.2 Modification of Gas Burner ...................................................................................51 3.6.3 Primary NOx Control Technology Status.............................................................. 54 3.6.4 Secondary Control of NOx Emission..................................................................... 56 3.7 Low emissions vs boiler performance/efficiency ?............................................................ 56 3.8 References.......................................................................................................................... 58 Eco-design Boilers, Task 4, Final | 30 September 2007 | VHK for European Commission III 4 BURNERS ....................................................................................59 4.1 Introduction....................................................................................................................... 59 4.2 Trends ................................................................................................................................ 59 4.3 Types .................................................................................................................................. 60 4.3.1 Surface burners..................................................................................................... 60 4.3.2 Jet burners............................................................................................................ 64 5 HEAT EXCHANGERS..................................................................... 68 5.1 Introduction....................................................................................................................... 68 5.2 Typology............................................................................................................................. 70 5.3 HE – material..................................................................................................................... 73 5.4 HE – shape and design ...................................................................................................... 74 5.4.1 Heat exchangers based on tubes (finned and un-finned) .................................... 74 5.4.2 Heat exchangers based on plates...........................................................................77 5.4.3 Heat exchangers based on integrated castings (aluminium, cast-iron)............... 78 5.4.4 Other heat exchangers types.................................................................................80 6 BOILER CONTROLS .......................................................................81 6.1 Introduction boiler control &components..........................................................................81 6.2 Power input control ........................................................................................................... 83 6.2.1 Pneumatic ratio-control........................................................................................ 83 6.2.2 Integrated mixing & control valve ........................................................................ 84 6.2.3 Turndown ratio oil boilers...................................................................................
Recommended publications
  • Technical Catalogue
    YUTAKI S80 SERIES Hitachi Air Conditioning Products Europe, S.A. Ronda Shimizu, 1 - Políg. Ind. Can Torrella 08233 Vacarisses (Barcelona) España Hitachi certifies that our products have met EU consumer safety, health and environmental requirements. Hitachi Air Conditioning Products Europe, S.A. is certified with: ISO 9001 of AENOR, Spain for its Quality Management accordance with the standard S80 SERIES YUTAKI ISO 14001 of AENOR Spain for its Environmental Management systems accordance with the standard. Hitachi air conditioning products are manufactured according to: ISO 9001 of JQA, Japan for its Quality Management accordance with the standard ISO 14001 of JACO, Japan for its Environmental Management accordance with the standard. Y B D E Hitachi fulfills with the Certification NF-PAC that recognize the quality I F I T R E C requirements for these heat pumps systems. HEAT PUMP HITACHI participates in the Eurovent Certification Programme; the certified data of certified models are listed in the Eurovent Certification Online Directory (www.eurovent-certification.com). Technical Catalogue RWH-(4.0-6.0)FS(V)NFE Indoor unit RAS-(4-6)H(V)RNME-AF Outdoor unit DHWS-(195/260)S-2.0H1E DHW tank TCGB0075 rev.0 - 11/2012 Printed in Spain PC-S80TE LCD controller TCGB0075 rev.0 - 11/2012 Contents C o n t e n t s General information 1 Features and benefits 2 General data 3 Capacities and Selection data 4 Acoustic characteristic curves 5 Working range 6 General dimensions 7 Refrigerant cycle 8 Piping work and refrigerant charge 9 Electrical wiring 10 Installation configurations 11 Optional functions 12 Troubleshooting 13 TCGB0075 rev.0 - 11/2012 General Index Contents ..............................................................................................................................3 1.
    [Show full text]
  • Heating with Gas PDF 469 KB
    Heating with Gas Modern Gas Heating With fluctuating energy prices and a growing concern for the environment, it pays to modernize your outdated gas-fired boiler. You will save money, and the environment too. Reduce unnecessary waste A modern solution There are an estimated 20 million homes in With the Vitodens 100-W, Vitodens 200-W and the United States with heating systems 20 Vitodens 222-F Series, we offer a complete years of age or older†. For most of them, a line of gas-fired condensing boilers. significant share of energy and money go to waste unnecessarily every year due to Equipped with a corrosion-resistant stainless At approximately 40%, domestic heating outdated technology and an improperly sized steel Inox-Radial heat exchanger, our Vitodens accounts for the greatest proportion system. Along with wasting energy, these Series boilers can safely operate at extremely of energy consumption and most CO 2 boilers contribute to climate change by low boiler water temperatures. For you, this emissions. By replacing an outdated needlessly releasing harmful CO emissions. heating system with a modern solution, 2 greater energy utilization translates into you can significantly improve energy reduced heating costs as well as a smaller utilization – reducing fuel consumption By replacing an outdated system with a environmental footprint. Plus, our Vitodens as well as harmful greenhouse gas-fired condensing boiler, a homeowner Series gas-fired condensing boiler comes gas emissions. can expect to save as much as 30%* on ready for the future by automatically adjusting their annual heating bills. This not only to all gas types – including conditioned biogas.
    [Show full text]
  • Technical Data Manual VITOTRONIC 100 Digital Boiler Control Unit for Modulating Temperature Heating Systems
    Technical Data Manual VITOTRONIC 100 Digital boiler control unit for modulating temperature heating systems Vitotronic 100 Model KW10B, Part No. 7834 238 Digital boiler control With outdoor reset control For heating systems with one modulating temperature heating circuit (without mixing valve) With analog boiler water temperature display Integrated pump connections Viessmann quick-connect plug-in system OpenTherm functionality Certified as a component part for Viessmann boilers 5604 122 v1.0 07/2011 Vitotronic 100, KW10B Technical Data Product Information The benefits at a glance: Standard equipment: digital boiler control Vitotronic 100, Model KW10B with; space heating circuit controlled by room thermostat adjustable fixed high limit and outdoor reset logic power supply cord single-stage or two-stage boiler control (depending on burner) outdoor temperature sensor integrated diagnostic system boiler temperature sensor built-in boiler low temperature protection DHW temperature sensor short assembly time and start-up due to diagnostic 120VAC boiler pump and DHW pump outputs and wire terminals digital boiler control: - for single-boiler systems - outdoor reset control - for heating circuits without mixing valves - for single-stage or two-stage burner - with analog temperature display - with integrated diagnostic system Application In conjunction with the following Viessmann boiler Fuel Minimum boiler water temperature Boiler Model and Series without low limit with low limit (average temp.) Oil-fired hot water Vitorond 100 Oil 104º F (40º
    [Show full text]
  • AHU Installation & Operating Instruction Manual
    INSTALLATION & OPERATING MANUAL Air Handling appliances AHU 800 AHU1200 AHU 1600 Contents Safety information 5 Specifications 7 Heating capacity 8 Cabinet and air supply dimensions 9 Dimensions for the AHU 800 model 9 Dimensions for the AHU 1200 model 11 Dimensions for the AHU 1600 model 12 Thermostat connections 14 1.0 Introduction 17 1.1 Standard features and benefits 17 1.2 Conformity 18 2.0 Installation 19 2.1 Locating the appliance 19 2.1.1 Conditioned space 19 2.1.2 Un-conditioned space 19 2.1.3 New construction 19 2.1.4 Mobile home 19 2.1.5 Closet 20 2.1.6 Garage 20 2.1.7 Serviceability 21 2.2 Positioning and mounting the appliance 21 2.2.1 Return air openings for ducting 21 2.2.2 Positioning the air handling unit 22 2.2.3 Adding air conditioning coils or heat pump coils 22 2.2.4 Mounting an appliance on the wall 23 2.2.5 Repositioning the air filter brackets 24 2.3 Duct work 26 2.3.1 Sizing the ducts 26 2.3.2 Ducting installed in conditioned space 27 2.3.3 Ducting installed in un-conditioned spaces 27 2.3.4 Making the return air openings 27 2.4 Connecting the appliance to the boiler 28 2.4.1 Sizing pumps 28 1 Section: Contents 2.4.2 Using Propylene Glycol 30 2.5 Connecting the appliance to a tankless water heater 30 2.6 Electrical connections 32 2.6.1 Wiring of the external pump and 120VAC line 33 2.6.2 Connecting line voltage - examples for different scenarios 33 3.0 Operation 45 3.1 Checklist for electrical conditions, ducting and water connections 45 3.2 Default settings 46 3.3 Default fan speed settings 46 3.4 Sequence of operation
    [Show full text]
  • Installation & Operation Manual
    Installation & Operation Manual Snow Melting Control 654 Introduction The Snow Melting Control 654 is designed to operate electric or hydronic equipment to melt snow or ice from a driveway, loading dock, sidewalk, patio, helipad or car wash bay. The snow melt surface temperature is controlled using slab outdoor reset to reduce operating energy costs. The 654 provides automatic start and stop when used with the Snow / Ice Sensor 090. Automatic start with a timed stop is available when used with the Snow Sensor 095. The 654 can operate a dedicated hydronic boiler or a mixing device. Isolation relays are required to operate line voltage pumps. Electric systems require a separate GFCI and electrical relay contactor. Features • Automatic Snow / Ice Detection • Supports Both Inslab & Retrofit Aerial Sensors • Manual Start With Timer • Programmable Schedule • tekmarNet® Communication Compatible • Warm Weather Shut Down • Cold Weather Cut Out • Idling • Snow Melt Zoning With Priority • Tandem Snow / Ice Detection • Slab Protection • Storm • EconoMelt • Manual Override • Snow Melt Zone Tracking • Scenes • Away Key • Exercising • Alert Output of 56 © 203 Watts Radiant Table of Contents Important Safety Information .............................................3 Sequence of Operation ................................................... 35 Applications .......................................................................4 Snow Melting Overview ................................................ 35 Single Zone with Boiler .................................................
    [Show full text]
  • VIESMANN Data Communication Vitocom, Vitodata, Vitosoft, Vitogate
    VIESMANN Data communication Vitocom, Vitodata, Vitosoft, Vitogate Technical guide TeleControl Vitocom 100 ■ Type GSM2 ■ Type LAN1 with Vitotrol app and Vitodata 100 Vitocom 300 ■ Type LAN3 with Vitodata 300 ServiceControl ■ Vitosoft 300 Building Automation ■ Vitogate 200, type KNX ■ Vitogate 300, type BN/MB 5414 671 GB 5/2017 Index Index 1. TeleControl — overview 1.1 Device types, operating functions and product benefits ............................................. 5 1.2 Applications and users ................................................................................................ 6 ■ Selection aids .......................................................................................................... 6 ■ Intended use ........................................................................................................... 6 1.3 Device and operating functions; general system requirements .................................. 7 2. TeleControl — Vitocom 100 2.1 Vitocom 100, type GSM2 ............................................................................................ 8 ■ Application .............................................................................................................. 8 ■ Remote switching and remote scanning ................................................................. 8 ■ Remote monitoring .................................................................................................. 8 ■ Languages .............................................................................................................
    [Show full text]
  • Versatronik 521 OT LON Submittal V1.0 394051.Pub
    Versatronik® 521 & 521D OT/LON Communication Gateway 120VAC Wall-mount 704052 24VAC DIN-rail mount 704072 Effective Date: June 15, 2010 Previous Revision: N/A Product Overview The Versatronik® gateway ® may be either part of a The OT/LON model has the The Versatronik® 521 & control panel (24VAC) ability to communicate 521D OT/LON gateway or stand-alone control directly with the boiler. This provides a communication device (120VAC). makes it possible to have a translation between building management OpenTherm® enabled boilers The gateway communicates system take control of your and LON® enabled BMS with an OT-enabled boiler. It OT enabled boilers. In this systems. allows a LON-enabled configuration, a thermostat management system to take is not required. control of the boiler. Special Features Please contact your boiler (power cord supplied) manufacturer for a complete Dimensions: Available data points: list of features available. 8” X 6.5” X 1.75” Boiler setpoint (200 X 165 X 45mm) (also writeable) Specifications Weight: 3.55 lbs (1.6 kg) Boiler water temperature Appearance: galvanized Maximum modulation Electrical: steel base with white metal level 120VAC Wall-mount or cover Current modulation level 24VAC DIN-rail mount Room temperature 24VAC DIN-rail mount: Room temperature Power Requirements: Mounting style: DIN-rail setpoint 120VAC Wall-mount: Supply Voltage: 24VAC (room thermostat is MAX 7.5W (power supply not included) required) 24VAC DIN-rail mount: Dimensions: Outside temperature MAX 12W 6.25” X 3.5” X 2.25” Return water temperature (160 X 90 X 60mm) Flue gas temperature Recommendations: Weight: 0.5 lbs (255g) Boiler heat exchanger Avoid running wires beside Appearance: tan-coloured temperature or near high voltage plastic enclosure Boiler fan speed 120/240VAC conductors.
    [Show full text]
  • How to Increase Your Business with Opentherm! March 15
    Welcome How to increase your business with OpenTherm! March 15 EXPANDING HEATING SOLUTIONS WITH OPENTHERM The simplest way of meeting ErP while increasing market and technology excellence Agenda • Legislation overview (ErP) • OpenTherm: the standard protocol in heating controls – Protocol evolution – Protocol advantages • OpenTherm certification process – Testing procedure – Automated test tool • The UK case (impacting the Building Energy Performance) • OpenTherm and Advanced services for IoT 3 Legislation overview ErP = Energy related Products ErP & ELD in one slide ErP Labelling ErP Labelling (813/2013;814/2013) (811/2013;812/2013) 2009/125/EC 2010/30/EC What ErP EU Commision Regulation and ELD Infromation Minimal performaces are? (immediately valid throughout EU28; no national laws and/or variants) For Requirements End-User Boilers (gas,electric,oil) HP (Electric,gas) <70KW Energy Label <400KW mCHP (<50KW elctric CE certification on power) For Products the products WH (gas,electric, involved oil) Products&Package V<500lt V<2000lt Water storage (cylinder) Min.Energy Energy label Performances (products and What they systems) Min Environmental Fiche require? requirements (product&systems) (Nox,Noise) Marcom&tec material © 2015 by Honeywell International Inc. All rights reserved. Toward OEM High Efficiency Integrated system! ErP for Heating Systems From September the 26th, 2015, the following products will be introduced in the market only if standards of efficiency, sound level and thermal protection of buffers are complied. Minimum Labeling with requirements, ErP-Label among others, according to according to the efficiency Energy-related new law on Products law energy efficency labelling Boilers Oil, Gas, Electric 0-400kW 0-70kW Heatpumps 0-400kW 0-70kW 0-400kW 0-70kW Cogeneration-Syst.
    [Show full text]
  • Gas 310 DDR OT BACIP Gateway BACNET 704501
    DDR Part Number: 704501 DDR OT/BACIP Gateway Communication Gateway for OpenTherm to BACnet IP Document Applicable to: DIN Rail Mount 704501 Applicable Controls: DDR Boiler Controls for MCA Pro / C230 ECO-A and Gas 310 ECO Series Technical, Installation and Configuration Information Cautionary Statement The information presented in this document is only to be used by those familiar with its application and use. Communication Communication IMPORTANT Read and save these instructions for future reference DDRA 015 001 v1.1 04/2010 About these instructions Warning Before you operate this boiler, read this manual carefully and take extra precautions to all safety and warning symbols or important items. The operating manual is part of the documentation along with the boiler. The installer is required to explain your heating system and boiler operating instruc- tions. Notice Please read this manual and retain for future reference. Improper installation, adjustment, altera- tion, service or maintenance can cause injury, loss of life or property damage. Refer to this manual for assistance or additional information or consult a qualified installer, service agency or the gas supplier. Caution danger Reference Risk of injury and damage to equipment. Refer to another manual or other pages in Attention must be paid to the warnings on this instruction manual. safety of persons and equipment. Specific information Information must be kept in mind to maintain comfort. Trademark Information OpenTherm® is a trademark of the OpenTherm Association. For more information, please visit: BACnet® is a registered www.opentherm.eu trademark of the American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc., 1791 Tullie Circle NE, Atlanta, GA 30329.
    [Show full text]
  • Honeywell T4 T4R T4M PRODUCT SPECIFICATION SHEET
    LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET The T4, T4M and T4R thermostats are designed to provide automatic time and temperature control of heating systems in homes and apartments. The T4 It’s compatible with 24- 230V on/off appliances such as gas boilers, combi-boilers and heat pump. Also works with zone valve applications but not with electric heating (240V). The T4M and T4R versions support also OpenTherm® appliances. The T4 and T4M are for wired on the wall installations and Honeywell T4 & T4M the T4R for wireless installations. T4R exist of a thermostat Programmable Thermostat and a Receiver box. The solution is designed with the installer in mind and includes a Receiver module with mounting options for directly on the wall or on a wall box. Wiring can be from below or from the back by lifting the terminal platform, which makes installation quick and easy. The thermostat has a large and clear fix segment display with backlight, simple programming philosophy all to make it easier to install and very user friendly. The T4 product line is ideal for consumers who want to control their comfort remotely with a modern design, Honeywell T4R simple to program and easy to use product. Programmable Thermostat FEATURES • Minimalistic and modern design makes it easy to blend • Receiver box with clear LED indication and override button. in any type of homes. • On/Off or OpenTherm® (T4R/T4M) compatible control. • Table stand or wall mounted thermostat options to fit new and replacement installations. • A flip up wiring platform for easy wiring. • Backlight for easier viewing in all light conditions.
    [Show full text]
  • Iot-Based Monitoring of a Community Energy Scheme
    )XWXUH&LWLHV Shipman, R and Gillott, M. 2019. SCENe Things: IoT-based Monitoring of a Community Energy Scheme. Future Cities and Environment, DQG(QYLURQPHQW 5(1): 6, 1–10. DOI: https://doi.org/10.5334/fce.64 TECHNICAL ARTICLE SCENe Things: IoT-based Monitoring of a Community Energy Scheme Rob Shipman and Mark Gillott This paper describes a technology platform for monitoring homes within a community energy scheme. A range of sensors was deployed to measure in-home environmental conditions, occupancy, electrical power, electrical energy, thermal energy, heating behaviour and boiler performance to better understand and predict energy consumption in individual homes and across the community. The community assets include solar photovoltaic panels that are deployed in an urban solar farm and on rooftops to generate energy that is used to charge a central battery. This community scale storage supports participation in grid services to help balance the national grid and in future phases to power a community heat network, electric vehicle charging and self-consumption within individual properties. The monitoring data helps develop insights to optimise this multifaceted system and to provide feedback to residents to visualise and control their energy consumption and encourage reductions in demand. It was found that a diverse range of Internet of Things technologies was required to generate this data and make it available for subsequent access and analysis. This diversity was consolidated in the cloud to provide a common data structure for consumption by other services via industry standard interfaces. The cloud infrastructure utilised scalable and easily deployable services that are readily available from Internet of Things platforms from the major technology companies.
    [Show full text]
  • ENGINEERED for COMFORT Take Comfort in a Brand You Know You Can Trust
    Home Lyric T6 Series programmable thermostat ENGINEERED FOR COMFORT Take comfort in a brand you know you can trust The Lyric T6 is the latest in programmable thermostats, developed by the Honeywell design team to provide an intuitive heating control that incorporates the best features of modern connected devices. Honeywell is continually innovating to create products that really make a difference to you and your customers. Meet the Lyric T6 Series, the next generation in programmable thermostats, designed to fit the lifestyle of today’s customers. Engineered by experts We’ve been innovating for 125 years, creating heating controls that lead the way in both wireless and smart technologies. Built for installers, Fit for all applications designed for customers The Lyric T6 Series works with any boiler and Developed as part of a future world of connected application, offering integration into almost controls, the Lyric T6 Series is thoughtfully every heating system. designed and equipped with touch-screen • Controls on/off (230V) boilers, OpenTherm technology, remote access via tablet or boilers and heating systems, using TPI or smartphone, recognisable icons, wireless modulating control, delivering superior connectivity and a suite of features in tune with energy efficiency without user interaction today’s home controls. • Can be used as a room temperature The Lyric T6 Series connects to existing wiring control in a standard S Plan or with intuitive set-up and operation, making Y Plan system it simple to install. It also connects to your customer’s home Wi-Fi network without • Can control underfloor requiring a modem or extra equipment.
    [Show full text]