Material Catalogue

Total Page:16

File Type:pdf, Size:1020Kb

Material Catalogue MATERIAL CATALOGUE We Prevent Corrosion Cathodic Corrosion Protection Table of Contents 4 l ANODES 4 l Impressed Current Anodes 4 l High Silicon Cast Iron Anode (FeSi) 8 l Mixed Metal Oxide Anode (MMO) 16l Graphite Anode 17l Platinized Titanium-Niobium Anode 20l Sacrificial Anodes 20l Magnesium Anode 24l Aluminum Anode 26l Zinc Anode 29l Accessories 29l Anode Backfill 31l Deep well groundbed accessories 33l TRANSFORMER RECTIFIERS & ELECTRICAL DEVICES 33l T/R Units 33l AC Power Rectifiers 47l Solar Generator 49l Thermoelectric Generator 50l AC Arrestor 51l Spark Gap 53l High Voltage Field Interference Capacitor Separator 54l Stray Current Protector 1 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection 55l Polarization Cell 56l CABLES & ACCESSORIES 56l Cables 60l Splicing Kit 61l Cable Connection 61l Thermit Welding 62l Pin Brazing 64l Connectors 65l Handy Cap & Cable Contact Hood 68l COATINGS, INSULATION MATERIALS & TAPES 68l Pipeline Cold Wrappings and Tapes 71l Heat Shrink Sleeves 74l Primer 75l Insulating Tapes 77l Insulating Kit 80l Insulating Joint 82l Rock Shield & Casing Carrier Pipe Isolator 86l TEST STATIONS & JUNCTION BOXES 86l Test post 92l Junction Box-Resistor Box 94l Anode Control Panel 2 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection 96l TEST & MEASURING EQUIPMENTS 96l Reference Electrodes 96l Cu/CuSO4 Cell 103l Zn/ZnSO4 Cell 104l Ag/AgCl Cell 107l Holiday Detector 111l GPS Data Logger for DCVG/CIPS 112l Interrupter 115l Ultra Sonic Corrosion Detector 117l Ultrasonic Pipe Tank Coating Wall Thickness Gauge 122l Insulator Tester 124l Pipe & Cable Locator 128l Earth Resistivity Tester 135l REMOTE MONITORING & CONTROL SYSTEM 138l Test Post Data Transmitter 140l CP Station Data Transmitter 142l Electric Clocking 144l CP Management System Software 3 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection ANODES . Impressed Current Anodes High Silicon Cast Iron Anode (FeSi) Characteristics Silicon Iron Anodes are used for Impressed Current Cathodic Protection Systems in a wide variety of Industrial Applications. Silicon Iron and Silicon Chromium Iron Alloys corrode relatively slowly. The low cost anode material offers long life at economical price. Materials There are two different alloy grades: N C -water environments. 4 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection Applications Silicon Iron Anodes are suitable for a wide range of industrial applications, in particular the following: - Industrial Use Type of Anode Installation - Pipelines Horizontal, Vertical or Deep well Groundbeds - Storage Tanks (External) Horizontal, Vertical or Deep well Groundbeds - Around Tanks - Water Storage Tanks (Internal) Anodes string suspended from tank roof - Jetties, Bridge Piling, Horizontal in the sea / River Bed - Sheet piling seawall or suspended between piles. Chemical Analysis 5 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection Cable Types V P V Chloride(PVC), Poly Ethylene (PE), Cross Linked Poly Ethylene (XLPE), High Molecular Weight Poly Ethylene (HMWPE), Poly Vinyl Fluoride (PVDF), Chloro Sulphonated Polyethylene (CSP),Ethylene Propylene Rubber (EPR) in various Combinations as insulating or sheathing. Anode Dimensions & Weight Alternative range of anodes in various lengths and weights, single or double ended are available on request. 6 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection Cable Connection to Anode and Encapsulation Canister Anodes Silicon iron anodes are available pre-packaged in galvanized mild steel canisters or cotton bags filled with coke-backfill. Canister anodes are the perfect impressed current anode for shallow vertical and horizontal surface groundbeds, as well as wet, marshy soil conditions where caving is likely to occur. 7 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection The primary anode element (FeSi Anode) is placed in a galvanized steel Canister filled with Coke backfill. The stable anode element passes current to this highly conductive calcined petroleum coke backfill. The backfill is well compacted inside the galvanized steel canister. To allow moisture to quickly migrate to the coke backfill for increased electrical conductivity, the anode is electrically connected to the steel canister, thereby accelerating the canister corrosion rate once the anode has been installed and energized. Mixed Metal Oxide Anode (MMO) To obtain the highest level of protection from an impressed current Cathodic Protection system, an anode with a very low consumption rate and high current capacity will be perfect. With mixed metal oxide anode, you get powerful protection and unsurpassed stability. The anodes are made using titanium substrates which are coated with a mixed metal oxide catalyst. The catalyst is thermally applied to the titanium to form an extremely chemical resistant bond. This special composition brings together the stability of titanium with the conductive properties of the mixed metal oxide catalyst to achieve superior performance and a very low consumption rate. Maximum allowable 12 V operating voltage Consumption rate 1 mg/A.y Maximum Current density 500 A/m2 (in Sea water) Maximum current density 100 A/m2 (in Coke or Fresh water) Maximum anode life 50 year 8 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection Applications Mixed metal oxide anodes have proven to operate effectively in all types of environments including areas with extremely low pH levels less than 1, and high chloride concentrations. MMO Rod anode MMO rod anodes perform well in all types of environments. Their mixed metal oxide coating prevents substrate attack in even highly acidic environments. The anodes have been used with great success in deep and conventional groundbeds, and in fresh, brackish and salt water electrolytes. These anodes can be used either bare or packaged in canisters containing petroleum coke breeze. For aqueous environments, the anodes can also be provided in a specially designed PVC perforated tube that directs current flow and provides extra protection to the anode. Dimensions Rod length 150 2500 mm Rod diameter 4 / 6 / 8 / 10 / 12 / 16 / 20 / 25 mm MMO Tubular anode To obtain the highest level of protection from an impressed current Cathodic Protection system, you need an anode with a very low consumption rate and high current capacity. With tubular mixed metal oxide anode, you get powerful protection and unsurpassed stability. The anodes are made using tubular 9 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection titanium substrates, which are coated with a mixed metal oxide catalyst. The catalyst is thermally applied to the titanium to form an extremely chemical-resistant bond. In soil and fresh water applications, the anodes have a recommended current density of approximately 100 amp/m2, and can be operated over 500 amp/m2 in sea water environments. Even at these relatively high discharge levels, the anodes will be consumed at less than 1.0 mg/amp- yr. The tubular configuration provides a larger surface area, which in turn permits greater current output and lower anode-to-electrolyte resistance. The tubular style also means lead wire connections can be made in the center of the anode. This connection is protected from moisture intrusion by a waterproofing sealant, which fills the entire anode tube. The ends of the anode are then covered with shrink tubing for a completely sealed electrical connection. Mixed metal oxide anodes have proven to operate effectively in all types of environments including areas with extremely low pH levels less than 1, and high chloride concentrations. They can be used singularly; their unique configuration also makes them ideal for use in strings on offshore platforms, deep well groundbeds or above ground storage tanks. In addition, the string anodes can be installed parallel to transmission pipelines, or used for other special applications. This anode can be used also in Canister. Diameter Length Max. Current Output in Max. Current Output in in mm ft mm Calcined Petroleum Coke Sea Water (Amp) (Amp) 0.75 19.1 2.0 610 2.6 13 0.75 19.1 4.0 1219 5.1 25 1.0 25.4 3.3 1006 11.1 50 1.25 31.8 4.0 1219 16.9 80 10 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection MMO Chain anode The tubular anodes are assembled as anode chain for deep groundbed installation. The current passes from the centre of any tube to the next. The materials used for the different parts of anodes and anode chains are suitable for satisfactory performance with regards to low ph-value and high chloride content of water as well as high concentration of chlorine gas. Anode chains are assembled with the desired length of cable and number of anodes to meet the design requirements. Tube length 2500 mm Tube diameter 25.4 / 40.0 / 45.0 / 50.8 mm MMO Mesh anode 11 Steffel GmbH www.steffel.com Tel: +49-5145-9891-0 Im Bulloh 6 [email protected] Fax:+49-5145-9891-90 29331 Lachendorf Germany Cathodic Corrosion Protection MMO Mesh Anode is designed specially for Cathodic Protection of steel in concrete.
Recommended publications
  • W Series Impulse Voltage Test System
    W SERIES IMPULSE VOLTAGE TEST SYSTEM Impulse Voltage Test System is used to generate impulse APPLICATION voltages from 100 KV to 2400 KV simulating lightning strokes The basic system is used to test any high voltage and switching surges with energies up to 240 KJ. equipment like The KVTEK make impulse voltage test systems are modular in ØPower Transformers construction, flexible and cover testing applications according to IEC, ANSI/IEEE and other national standards. ØDistribution Transformers The basic system can be upgraded in various ways to allow ØCable (Type Tests) optimizing the impulse test system for tests on different high ØSurge Arresters (impulse current tests) voltage equipments. ØMotor / Generators The system operation is user friendly and incorporates all the ØInsulators necessary features of Impulse Voltage Test. ØBushings ØGIS ØInstrument Transformers ØResearch & Development and Universities FEATURES ØLow internal inductance ØEasy and quick reconfiguration to suit different testing needs ØUser friendly operation through computer and microprocessor controlled hardware. ØEquipped with resistors for performing lightening full, lightening chopped and switching impulse tests on wide range of loads. ØAutomatic grounding device and security grounding system (available as an option). ØAlarm annunciation to display all fault conditions. ØFiltered clear air constantly supplied through the sphere gaps while the system is running. ØReliable and fail safe triggering circuitry. KVTEK POWER SYSTEMS PRIVATE LIMITED STRUCTURE CHARACTERISTICS CHARGING RECTIFIER ØAll the coupling sphere gaps are mounted in an insulated D100-0.05 (100 kV, 50 mA) OR D100-0.15 DC (100 kV, 150 mA) tube and every level of sphere gaps is equipped with spark Charging Power Supply comprises of: observation panel.
    [Show full text]
  • The Pin Brazing System Is Ideally Suited to This
    PIN BRAZING A metalurgically safe method of making electrical connections to pipelines and other metallic structures, which are to be cathodically protected or electrically earthed. Glenn Symington BAC Corrosion Control Ltd, Stafford park 11, Telford, UK.TF3 3AY INTRODUCTION Pin Brazing is an easy, metalurgically safe method of making electrical connections to steel and ductile iron pipelines as well as other metallic structures, which are to be cathodically protected or electrically earthed. Whilst the system has major advantages over alternative systems, some of which can cause unacceptable levels of irreversible damage to the structure itself, it is imperative that operator training and equipment maintenance is to a high standard. This paper explains the pin brazing process, the technique, the effects of this, alternative processes such as Cad Weld and also demonstrates system operation. THE PROCESS The BAC pin brazing technique is based primarily upon Electric-arc silver soldering using a specially designed portable pin brazing unit, a hollow brazing pin containing silver solder and flux. The brazing process is initiated by depressing a trigger on the brazing gun. This as with most forms of electrical welding simply completes a circuit through which a DC current is passed. The pin tip is the point of highest resistance at which point an arc is drawn, melting the solder flux whilst simultaneously heating the lug material and the surface of the structure or pipeline to the required soldering temperature. After approximately 1.5 seconds the circuit is mechanically or electronically broken, the solenoid is de-energised and the brazing pin is pushed forward into the molten pool of brazing alloy.
    [Show full text]
  • Installation Instructions to Ensure Proper Compres Installing Units with Any of the Optional Accessories Sor and Blower Operation
    INSTALLATION Litho U.S.A. 2003 INSTRUCTIONS LGC090S, LCC090S (7.5 Ton) WARNING LGA090H, LCA090H (7.5 Ton) Improper installation, adjustment, alteration, ser (8.5 Ton) vice or maintenance can cause property damage, LGA102H, LCA102H personal injury or loss of life. Installation and ser vice must be performed by a qualified installer, serĆ LGC102S, LCC102S (8.5 Ton) vice agency or the gas supplier LGA120H, LCA120H (10 Ton) Table Of Contents LGC120S, LCC120S (10 Ton) Dimensions. 1 LGC150S, LCC150S (12.5 Ton) Parts Arrangements. 2 L SERIES PACKAGED UNITS Shipping and Packing List. 3 504,785M General. 3 6/2003 Supersedes 504,563M Requirements. 3 Unit Support. 3 Electrical Connections. 7 Duct Connections. 4 Blower Operation and Adjustments. 9 Rigging Unit For Lifting. 4 Cooling Start−Up. 13 Condensate Drains. 4 Gas Heat Start−Up. 17 Gas Piping. 5 Heating Operation and Adjustments. 18 Pressure Test Gas Piping. 5 Electric Heat Start−Up. 19 High Altitude Derate. 6 Humiditrol® Start−Up and Operation. 20 Factory−Installed Options. 6 Service. 22 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE LCA SHOWN 06/03 504,785M *2P0603* *P504785M* LGA/LGC/LCA/LCC090, 102, 120, & 150 DIMENSIONS − LGA/LGC HEAT SECTION SHOWN *Reheat coils are factory−installed in Humiditrol units only. OPTIONAL OUTDOOR CONDENSER COIL AIR HOOD INTAKE AIR CONDENSER (Factory or COIL FAN (2) Field Installed) AA4 (102) 4 (102) BB 28 28 (711) (711) BOTTOM 51/2 20 61/4 20 SUPPLY AIR (140) (508) (159) (508) OPENING CONDENSER EVAPORATOR COIL COIL EE INTAKE BOTTOM AIR RETURN AIR CENTER BLOWER
    [Show full text]
  • FINDER Relays 7P Series
    7P Series - Surge Protection Device (SPD) Features 7P.21.8.275.1020 7P.22.8.275.1020 SPD Type 2 Surge arrester range - single phase systems • Surge arrester suitable for 230V system/ applications • Protects equipment against overvoltage caused by lightning strikes or switching transients 7P.21.8.275.1020 Varistor protection L - N 7P.22.8.275.1020 Varistor protection L - N + spark-gap protection N - PE • SPD Type 2 (1 varistor + 1 spark-gap) • SPD Type 2 (1 varistor) Spark-gap protection N - PE avoids earth • Combination of replaceable varistor and • Replaceable varistor module leakage current encapsulated spark gap modules • Visual and remote signalling of varistor status • Visual indication of Varistor status - • Visual and remote signalling of varistor status Healthy/Replace • Remote signalling contact of Varistor status Connector (07P.01) included • Replaceable modules • Complies with EN 61643-11 07P.01 07P.01 • 35 mm rail (EN 60715) mounting 12 11 14 12 11 14 7P.21 / 7P.22 Screw terminal L / N () L PE (L / N) N For outline drawing see page 6 SPD specification L-N N-PE Nominal voltage UN 230 V AC 230 V AC — Maximum continuous operating voltage UC 275 V AC / 350 V DC 275 V AC / 350 V DC 255 V AC Nominal discharge current (8/20 μs) In 20 kA 20 kA 20 kA Maximum discharge current (8/20 μs) Imax 40 kA 40 kA 40 kA Voltage protection level at 5kA UP5 0.9 kV 0.9 kV — Voltage protection level at In UP 1.2 kV 1.2 kV 1.5 kV Response time tA 25 ns 25 ns 100 ns Short-circuit proof at maximum overcurrent protection 35 kArms 35 kArms — Maximum overcurrent
    [Show full text]
  • Zinc Anodes-Prepacked
    CABLES CONNECTION PDS/VTS/CC/10 (CATHODIC PROTECTION) GENERAL In Cathodic Protection system, either in sacrificial CP system or Impressed current CP System, the cables such as header cable, bonding cable, monitoring cable etc needs to be connected to the pipeline, tank or any other intended structure for CP. The most commonly used methods for cable connections are as follows - Pin brazing and - Thermit welding PIN BRAZING Pin brazing is effectual method to attach copper conductor cable to steel or metallic structure such as tank or pipelines, this method is particularly used to connect cables to pipelines including monitoring cable, header cable, bonding cables. The pin brazing technique is based primarily upon Electric-arc silver soldering using a specially designed portable pin brazing unit, a hollow brazing pin containing silver solder and flux. The brazing process is initiated by depressing a trigger on the brazing gun. There are two basic types of connection that can be made Threaded Type Connection using an M8, M10 or M12 Threaded Brazing Pin. A normal copper crimp lug (supplied separately) is attached to the stud and secured in place with locknuts and washers (included with pin). Direct Type Connection using an 8mm Direct Brazing Pin and a Pin Brazing cable lug, available to suit cable sizes 10mm2 to 50mm2 For each type of connection a ceramic ferrule is required for each braze in either 12mm (threaded connection) or 8mm (direct connection) THERMIT WELDING Thermit welding is cost effective method to attach copper conductor cable such as monitoring cable, header cable, bonding cables to pipelines or tanks or any other structure intended for CP.
    [Show full text]
  • Ensuring the Integrity of Critical Pipe-To-Cathodic Protection System Connections
    Paper No. 08006 Ensuring the Integrity of Critical Pipe-to-Cathodic Protection System Connections Chris Googan Anticorrosion Engineering Limited Shrewsbury, England E-mail: [email protected] Glenn Symington BAC Corrosion Control Limited Telford, England Fax: +44 1952 290325 E-mail: [email protected] ABSTRACT Achieving cathodic protection (CP) on buried or immersed pipelines requires the connection of copper conductors to carbon steel. Connections are needed both for the primary current drain cables; and for the various test leads and bonds that enable the CP system to be monitored and managed. These connections are all too often made in less than ideal conditions (in the field or offshore), and with the urgency needed to keep pace with the pipeline installation schedule. Moreover, once made, they will be permanently out of sight; yet must remain intact throughout the entire life of the pipeline. This paper recaps the history of the available cable connection techniques in common use: thermite welding, pin brazing and conducting adhesives; and compares their relative merits. The comparison assesses their practicability, including health and safety, cost and the reliability of the resulting connections. In addition, the effects of the thermal processes on the metallurgical condition of the pipe wall are reviewed in the light of micro-hardness measurements. The metallurgical implications of using thermal connection techniques on high strength (>700 MPa) thin walled lines, of the type currently under review for future projects, are considered. 1. INTRODUCTION The cathodic protection (CP) of buried or immersed equipment involves the application of tried and trusted electrochemical principles. This electrochemistry is implemented, monitored and controlled by means of electrical circuitry, the design of which is rarely complex.
    [Show full text]
  • The Basics of Surge Protection the Basics of Surge
    The basics of surge protection From the generation of surge voltages right through to a comprehensive protection concept In dialog with customers and partners worldwide Phoenix Contact is a global market leader in the field of electrical engineering, electronics, and automation. Founded in 1923, the family-owned company now employs around 14,000 people worldwide. A sales network with over 50 sales subsidiaries and 30 additional global sales partners guarantees customer proximity directly on site, anywhere in the world. Our range of services consists of products associated with a wide variety of electrotechnical applications. This includes numerous connection technologies for device manufacturers and machine building, components for modern control cabinets, and tailor-made solutions for many applications and industries, such as the automotive industry, wind energy, solar energy, the process industry or applications in the field Iceland Finland Norway Sweden Estonia Latvia of water supply, power transmission and Denmark Lithuania Ireland Belarus Netherlands Poland United Kingdom Blomberg, Germany Russia Canada Belgium distribution, and the transportation Luxembourg Czech Republic France Austria Slovakia Ukraine Kazakhstan Switzerland Hungary Slovenia Croatia Romania South Korea USA Bosnia and Serbia Spain Italy Herzegovina infrastructure. Kosovo Bulgaria Georgia Japan Montenegro Portugal Azerbaijan Macedonia Turkey China Greece Tunisia Lebanon Iraq Morocco Cyprus Pakistan Taiwan Israel Kuwait Bangladesh Mexico Algeria Jordan Bahrain India
    [Show full text]
  • Protection Characteristics of Spark Gaps
    fz <?rz>7orz> /fur-- *9- Protection characteristics of spark gaps Marja-Leena Pykala Veikko Palva 27 deceived ' ccq 2315 S3 OSTl Report Helsinki University of Technology High Voltage Institute Espoo, Finland 1997 DISCLAIMER Portions of this document may be illegible electronic image products. Images are produced from the best available original document. Report TWH ; Helsinki University of Technology High Voltage Institute ^*gh Voltage Itvs^ Protection characteristics of spark gaps Marja-Leena Pykala Veikko Palva ISSN 1237-895X ISBN 951-22-3438-6 January 27, 1997 Espoo, Finland 2 (24 ) Preface The High Voltage Institute of Helsinki University of Technology (HUT) has operated as the National Standards Laboratory of High Voltage Measurements since October 1995. Research is largely concentrated on high voltage measurement and metrology. This project concentrated on practical issues: distribution transformers and protective spark gaps. The project was supervised by the following expert group: Jarmo Elovaara from IVO Power Engineering Oy, Juha Sotikov from Finnish Electricity Association and Esa Virtanen from ABB Transmit Oy as well as Martti Aro, Matti Karttunen and Veikko Palva from Helsinki University of Technology. Abstract Distribution transformers in rural networks have to cope with transient overvoltages, even with those caused by the direct lightning strokes on the lines. In Finland, the 24 kV network conditions, such as wooden pole lines, high soil resistivity and isolated neutral network, lead into fast transient overvoltages. The distribution transformers (< 200 kVA) have been protected and a major part is still protected using protective spark gaps. The protection characteristics of different spark gap types were studied widely using improved measuring techniques.
    [Show full text]
  • Residual Resistance Simulation of an Air Spark Gap Switch
    Residual resistance simulation of an air spark gap switch. V. V. Tikhomirov, S.E. Siahlo∗ February 27, 2015 Research Institute for Nuclear Problems, Belarusian State University, Bobruiskaya 11, 220030 Minsk, Belarus Abstract The numerical simulation of an air spark gap has been carried within two theoretical models. The kinetic one [1] allowed us to calculate time dependencies for the residual resistance (0.2 - 0.4 Ohm for our selection of a circuit parameters), the spark gap channel width, the electron number density, the mobility, the conductivity, the ionization degree, the magnetic field in the discharge channel, the channel inductance and the electron drift velocity. Simulating a real circuit and taking into account a spark gap residual resistance demonstrates good agreement of both models with the experimental data, while that without taking into account this resistance overestimates the maximal current in the circuit by approximately 5%. 1 Introduction The high-voltage spark gap switches are essential elements of the circuits containing magneto- cumulative generators, capacitive and inductive energy storages, electro-explosive circuit break- ers etc. Very frequently spark gaps affect sufficiently the operation of the circuits and one cannot satisfactorily describe main elements functioning in the absence of a quantitative model of the processes occurring in the spark gaps. This article is devoted to the comparison of two such models considering a real circuit, where the influence of a high-voltage spark gap results in a decrease of the maximal current for about 5%. We review in detail the model [1] based on the time dependent method for the electron number density simulation in the air spark gap channel using an anisotropic solution of the kinetic equation [2].
    [Show full text]
  • I-N + Silicon Structures
    University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Electrical & Computer Engineering, Department P. F. (Paul Frazer) Williams Publications of May 1993 Inhibition of surface-related electrical breakdown of long p+-i-n+ silicon structures F. E. Peterkin University of Nebraska - Lincoln P. F. Williams University of Nebraska - Lincoln, [email protected] B. J. Hankla University of Nebraska - Lincoln L. L. Buresh University of Nebraska - Lincoln S. A. Woodward University of Nebraska - Lincoln Follow this and additional works at: https://digitalcommons.unl.edu/elecengwilliams Part of the Electrical and Computer Engineering Commons Peterkin, F. E.; Williams, P. F.; Hankla, B. J.; Buresh, L. L.; and Woodward, S. A., "Inhibition of surface-related electrical breakdown of long p+-i-n+ silicon structures" (1993). P. F. (Paul Frazer) Williams Publications. 6. https://digitalcommons.unl.edu/elecengwilliams/6 This Article is brought to you for free and open access by the Electrical & Computer Engineering, Department of at DigitalCommons@University of Nebraska - Lincoln. It has been accepted for inclusion in P. F. (Paul Frazer) Williams Publications by an authorized administrator of DigitalCommons@University of Nebraska - Lincoln. inhibition of surface-related electricall breakdown of long p+-i-n+ silicon structures F. E. Peterkin, P. F. Williams, B. J. Hankla, L. L. Buresh, and S. A. Woodward Department of Electrical Engineering, University of Nebraska-Lincoln, Lincoln, Nebraska 68.588-05Il (Received 22 January 1992; acceptedfor publication 10 February 1993) Semiconductors such as silicon and GaAs appear attractive for use in high voltage devices becauseof their high bulk dielectric strength. Typically, however, such devicesfail at a voltage well below that expecteddue to a poorly understood,surface-related breakdown process.In this letter we present empirical results which show that such breakdown of long silicon pf-i-n+ devicescan be inhibited by the application of weak visible or near-infrared illumination.
    [Show full text]
  • Two-Electrode Spark Gap Preamble
    Two-Electrode Spark Gap Preamble INTRODUCTION PRINCIPLES OF OPERATION The range of two-electrode spark gaps offered by e2v A simple two-electrode spark gap is shown in Fig. 1. At low technologies comprises hermetically sealed gas-filled switches voltages the gap is an insulator. As the voltage increases, the available with DC breakdown voltages from 400 V to 50 kV. few free electrons (present in the gap as a result of cosmic Two-electrode spark gap applications include voltage surge radiation and other ionising effects) are accelerated to higher protection, lightning protection, single-shot pulse generators, velocities, until they are able to ionise atoms of the gas filling. high energy switches and turbine engine ignition circuits. This leads to an avalanche effect as the additional electrons produce further ionisation and as the current builds up, the PRINCIPAL FEATURES voltage falls (see Fig. 2). There is a range of current over which emission from the cathode takes the form of a glow discharge * No Standby Power Consumption and the voltage is almost constant. * Consistent Breakdown Voltage * High Current Capability GAS FILLING MAIN ELECTRODE GAP 4169B * Fast Switching * Rugged and Reliable over Temperature Range * Lightweight TWO-ELECTRODE SPARK GAP SELECTION When considering the choice of spark gap, the following factors should be taken into account: * Application * Peak Current and Waveform * Coulombs per Shot INSULATOR * Maximum Repetition Rate * Main Gap Voltage Fig. 1. Basic structure of a typical 2-electrode spark gap * Environmental Conditions A further increase in current produces cathode heating by ion The e2v technologies two-electrode spark gap preamble should bombardment, leading to the formation of emission sites and be read in conjunction with the relevant product data sheet to another voltage drop across the gap.
    [Show full text]
  • PS/6772 It Should Be Noted Here That If, for Any Reason, This Feedback
    14 ins-SI/Note MAE/68~5 5.10.1968 K66 KICKLJ PROJECT C. Carter Introduction This note describes the supplies and associated equipment used to power the FK66 Kicker Magnet. A pulse forming network consisting of two low loss 16 coaxial cables in parallel is charged from a H.V. power supply. At the desired maximum voltage the stored energy in the cables is switched into the magnet which is also matched by a triggered spark gap. As the magnet is a balanced four terminal network? both positive and negative supplies are needed, as are the associated pairs of cables and spark gaps. A change—over switch selects the direction of ‘kick'. A choice of 3 bunch or 6 bunch ejection required two pairs of charging cables (termed the ‘short' and 'long' cables), and thus four individual power supplies (Fig. 1). General description 2 The four similar power supplies are all housed in an oil filled tank. The control element in each is a ML8495 tube, which is held normally off by a rectifier A.C. voltage obtained from a power oscillator. A ramp function generator modulates this oscillator to turn the tube on, which charges the cables (Figs. 2 and 3). A voltage divider chain on the output is used for measurement and also as a reference point for comparison with the applied ramp function. PS/6772 It should be noted here that if, for any reason, this feedback 100p is broken9 control of the series tube ML8495 will be lost resulting in full output voltage on the cables.
    [Show full text]