2 Victoria Avenue, Perth, WA Affinity Village Club House, Baldivis, WA
Total Page:16
File Type:pdf, Size:1020Kb
CASE STUDIES 2013 1 2 Victoria Avenue, Perth, WA 54 2 Affinity Village Club House, Baldivis, WA 58 3 ANZ Centre, Melbourne, VIC 60 4 Darling Quarter, Sydney, NSW 62 5 Green and ‘future proofed’: ISPT’s Green Star portfolio 66 6 Lend Lease: Greening the residential sector one apartment at a time 68 7 McDonald’s Kilsyth South Restaurant, Melbourne, VIC 70 8 Metcash Distribution Centre, Sydney, NSW 74 9 Monash University Briggs Hall and Jackomos Hall, Melbourne, VIC 78 10 Sydney Water Corporate Headquarters, Sydney, NSW 82 11 The GPT Group Head Office Fitout, Sydney, NSW 86 12 The Key Spec 1, Keysborough, VIC 90 53 CASE STUDY 1 2 VICTORIA AVENUE 2 Victoria Avenue may seem small when compared to some of its high-rise counterparts in the Perth CBD, but as the very first project in Western Australia to achieve Green Star As Built certification, 2 Victoria Avenue represents big thinking, big sustainability and big leadership. A showcase office development, 2 Victoria Avenue is the first in Western Australia to achieve the Green Star certification ‘trifecta’ of Design, As Built and Interiors ratings. And, through the sustainable initiatives implemented and the achievement of Green Star certified ThE project ratings across all project phases, Stockland at A glANCE has delivered a ‘future-proofed’ asset that will deliver ongoing benefits through a 6 Star Green Star – Office Design v2 quality indoor environment and operational rating representing ‘World Leadership’ cost savings. in environmentally sustainable design When asked why it was so important 5 Star Green Star – Office As Built v2 for Stockland to achieve a Green Star and 5 Star Green Star – Office As Built rating for the development – Interiors v1.1 ratings representing a first in the Perth market – Stockland’s ‘Australian Excellence’ in Environmental Sustainability Manager, environmentally sustainable Greg Johnson, gives a simple answer. construction and interiors “Sustainability is embedded in The first development in Western our entire business and we have been Australia to achieve Green Star achieving Green Star ratings across a range As Built certification. 1 of sectors since 2008. The achievement of a Green Star As Built rating was a key 54 We“ set out to deliver a flexible and sustainable 5 Star Green Star - rated office building that could ‘stand the test of time.’ pROJECT DETAIlS Owner ”Greg Johnson Stockland Environmental Sustainability Manager Stockland Location 2 Victoria Avenue, Perth, Western Australia Size 7,200 square metres NLA Project TEAM commitment from the beginning of the Architect/Landscaping Consultant project. The As Built rating authenticates the Woodhead design of the building and will ensure that 2 Victoria Avenue can meet our tenants’ WhAT 2 vICTORIA Project Manager APP needs for a high performance, sustainable AvENUE AChIEvED: office space, now and into the future.” Structural/Civil Engineer Johnson explains that while Water Arup Stockland’s initial objective was to obtain a Reducing 2 Victoria Avenue’s 5 Star Green Star – Office Design v2 rating reliance on potable water consumption Main Contractor Diploma Civil Construction for the base building design, an aspirational was a top priority for the project team through approach to sustainability and partnership the building’s design and construction. Building Service Engineer/ with industry leaders enabled the developer “We are very conscious of the impact of local ESD Consultant to go one step further to achieve a ‘World conditions. At a time when Western Australia AECOM Leadership’ 6 Star Green Star – Office was in the throes of drought and with utility Design rating. prices ever on the rise, achieving the best “When it came to construction, possible water conservation outcome was we again decided to target 5 Star Green very important,” explains Johnson. For the As Star, and were pleased to achieve this Built submission, the project achieved 11 of level of certification for both the base the 13 points available under the Green Star building and our own fitout. Changing ‘Water’ category, scoring all available points circumstances meant that there were a for potable water efficiency. few aspects of the original design that Water is captured from 5 Star couldn’t be practically implemented WELS-rated showers and taps before being through construction, but the building has diverted for treatment by the building’s proven extremely successful nonetheless. onsite greywater system. This treated water We are thrilled with the way the building provides 100 per cent of water used for toilet is performing three years on, and pleased flushing across the development. Waterless with the recognition we have received for urinals further reduce water consumption our leadership in achieving a Green Star and fire test water is returned to the onsite As Built rating,” says Johnson. storage tank to be reused for site irrigation. 55 1 56 CASE STUDY / 2 Victoria AveNUe Together, the water efficiency measures implemented at 2 Victoria Avenue are conserving up to 4.4 million litres per year, a saving that equates to nearly two Olympic-sized swimming pools. Now a relatively common feature in the Australian commercial office sector, at the time that 2 Victoria Avenue was designed greywater treatment had never been implemented in a commercial building within the Perth CBD. Through the successful installation of the system, 2 Victoria Avenue became the Western Australian ‘test case’ for greywater. Project ESD Consultant, Graham Agar of AECOM explains how the implementation of the system at 2 Victoria Avenue has paved the way for recycled water treatment within the Perth market. “2 Victoria Avenue was one of the first projects to achieve an approval in principal for the design of the system, but the first Perth CBD project to have the system tested, commissioned and approved for operation. The commissioning, testing and reporting procedure required to be undertaken is now well understood by both contractors and the Western Australian Department of Health, Energy Although the wind-turbine technology meaning future projects will benefit from The energy efficiency initiatives was not implemented, Johnson is proud of the lessons learnt at 2 Victoria Avenue.” at 2 Victoria Avenue, which include T5 the leadership that Stockland and AECOM lighting, sub-metering and motion-sensors, were able to demonstrate by incorporating IEQ zoned lighting, and active chilled beam air the turbines into the building’s design. In addition to the pioneering approach conditioning, together save the building around “Knowing what we know now, we might have taken to the delivery of environmentally 50kg of CO2 per square metre of net lettable looked to other alternative energy generation sustainable outcomes, fitout flexibility, area each year – equating to a saving of initiatives, but at the time we were committed occupant amenity and indoor environment approximately 350 tonnes of CO2 each year to the turbines not only for their energy- quality (IEQ) were all high priorities. At the and around $61,000 in electricity costs. generation capacity, but as a way of visually time that the building was designed, For its Green Star – Office Design rating, demonstrating our environmental commitment the Perth market was at the peak of the 2 Victoria Avenue was recognised with a to the community. We’ve achieved great resources boom and the building was Green Star ‘Innovation’ point for the inclusion results for energy from other initiatives, so in specifically designed to accommodate the of three 2.5kW wind-powered helical turbines, the end I think we came out ahead. You never staff fluctuation and workforce mobility typical capable of generating between 6,600 know if you don’t try,” he concludes. to the resources sector. Floor plates can be and 9,600 kWh per year. However, public It is clear that the leadership shown easily reconfigured to accommodate multiple concerns and technology barriers meant that and the knowledge and experience gained tenancies, which are individually monitored the turbines were not installed at the time from 2 Victoria Avenue has inspired other and controlled to maximise energy-usage of construction. developers and project teams in Western efficiencies across the building. The building’s “The wind turbines were ideal on paper Australia to strive for Green Star ratings. active western façade incorporates but, as project teams so often discover, when Nowhere is this more evident than the automated shading, which acts to increase it came to implementation, there were external exponential growth in Green Star certifications occupant comfort by managing glare and concerns raised and risks identified with the achieved in Western Australia in 2012 – triple heat gain. The specification of low-volatile technology. As a developer, it’s important to that of the year before. By pioneering green organic compound (VOC) finishes and understand that no building exists or functions technologies and sharing their successes, low-formaldehyde wood composite products in isolation. In view of this, the decision was the 2 Victoria Avenue project team has throughout also make 2 Victoria Avenue a made not to pursue the implementation of forged a new, more sustainable path healthy and comfortable place to work. the turbines,” says Johnson. for the urban landscape of Perth. 57 CASE STUDY 2 AFFINITY VILLAGE CLUB HOUSE A Green Star rating leaves a community building, and individual metering ThE project with a lasting legacy – and a cost effective and motion sensors