Consolidated Edison Company of New York, Inc. 2020-2022 Gas Operations Capital Programs/Projects Updated

Total Page:16

File Type:pdf, Size:1020Kb

Consolidated Edison Company of New York, Inc. 2020-2022 Gas Operations Capital Programs/Projects Updated EXHIBIT ___ (GIOSP-1) PAGE 1 of 157 CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 2020-2022 GAS OPERATIONS CAPITAL PROGRAMS/PROJECTS UPDATED EXHIBIT ___ (GIOSP-1) PAGE 2 of 157 Year Total CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 2020-2022 GAS CAPITAL Current Budget PROGRAMS Total Dollars ($000) Project/Program Description Category Code RY1 RY2 RY3 Distribution System Improvement Programs Distribution Integrity Main Replacement Program Regulatory Required $ 342,305 $ 349,151 $ 360,320 Distribution Integrity Main Enhancement Operationally Required $ 13,081 $ 13,357 $ 13,610 Service Replacement Program Operationally Required $ 119,120 $ 120,619 $ 123,239 Large Diameter Gas Main Program Strategic $ 11,445 $ 12,014 $ 12,609 Isolation Valve Program Strategic $ 5,118 $ 4,999 $ 5,000 Optimain - Main Replacement Prioritization Software Strategic $ 1,000 $ 750 $ - Sub-Total $ 492,069 $ 500,890 $ 514,778 System Reliability Winter Load Relief Operationally Required $ 17,719 $ 17,495 $ 17,494 Gas Reliability Improvement Program Strategic $ 9,159 $ 11,499 $ 11,500 Regulator Station Revamp Strategic $ 5,000 $ 5,000 $ 5,000 Tarrytown-Ossining HP Tie Strategic $ 2,626 $ 2,627 $ 2,627 Ossining IP Upgrade to HP Strategic $ 3,210 $ 3,211 $ 3,211 Purchase Armonk High Pressure Tie Strategic $ 1,196 $ 1,167 $ 1,167 Rehabilitation of the Gas Supply Main to City Island Strategic $ 3,826 $ - $ - Sub-Total $ 42,736 $ 40,999 $ 40,999 Distribution System Improvement Programs Total $ 534,805 $ 541,889 $ 555,777 Transmission Programs and Projects Transmission Risk Reduction and Reliability Projects Remotely Operated Valves (ROVs) Strategic $ 3,519 $ 3,519 $ 3,519 Transmission Main Leaks Strategic $ 5,238 $ 7,885 $ 7,885 Westchester / Bronx Border to White Plains Strategic $ 45,776 $ 48,188 $ 47,864 Newtown Creek Metering Station Strategic $ 6,345 $ 4,824 $ - Bronx River Tunnel to Bronx Westchester Border Strategic $ 44,276 $ 42,975 $ 42,651 Bronx River Tunnel and Easement Strategic $ 11,651 $ 15,001 $ - Gate Station Outlet Piping & Overpressure Protection - Manhattan Strategic $ - $ 8,000 $ 8,000 (CONFIDENTIAL*) Rye Gate Station Overpressure Protection Strategic $ 1,000 $ - $ - Queens Transmission Upgrade (NESE approved) Operationally Required $ 36,000 $ 27,000 $ 1,500 Sub-Total $ 153,805 $ 157,392 $ 111,419 Pressure Control PC - Corroded Gauge Lines Strategic $ 50 $ 52 $ 52 PC - Uncoated Piping Strategic $ 101 $ 104 $ 104 PC - Pressure Monitoring / Telemetric Strategic $ 2,279 $ 2,280 $ 2,280 PC - Replace Iroquois Station Roofs Strategic $ 150 $ - $ - PC - Replace Network and Control System at Iroquois Gate Station Strategic $ 2,200 $ - $ - PC - Station Gas Detector & Fire Detection/Alarm Systems Strategic $ 325 $ 200 $ - PC - Replace Odor-Eyes at Gate Stations Strategic $ 100 $ 100 $ 100 PC - Replace Gas Chromatographs Strategic $ 390 $ 390 $ 120 PC - Replace Obsolete Teledyne RTUs Strategic $ 300 $ 300 $ 300 PC - Regulator Automation Strategic $ 9,300 $ 9,301 $ 9,300 PC - Gridboss / Automated Adaptive Controls Strategic $ 506 $ 888 $ 888 PC - System Automation and Reliability Enhancement Program Strategic $ 1,500 $ - $ - PC - Unserviceable Equipment Strategic $ 507 $ 506 $ 506 PC - Replace Regs, Valves & Strainer 2 and Larger Strategic $ 507 $ 506 $ 506 Sub-Total $ 18,215 $ 14,627 $ 14,156 Transmission Programs and Projects Total $ 172,020 $ 172,019 $ 125,575 *Will be distributed pursuant to a protective order UPDATED EXHIBIT ___ (GIOSP-1) PAGE 3 of 157 Year Total CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 2020-2022 GAS CAPITAL Current Budget PROGRAMS Total Dollars ($000) Project/Program Description Category Code RY1 RY2 RY3 Customer Connections Customer Connections Regulatory Required $ 84,613 $ 75,088 $ 72,949 New Business - Regulator Stations Operationally Required $ 7,165 $ 8,823 $ 8,823 Customer Connections Total $ 91,778 $ 83,911 $ 81,772 Technical Operations Liquefied Natural Gas (LNG) LNG - Install Vaporizer 1 Strategic $ 1,000 $ - $ - LNG - Plant Boil-Off Compressor Strategic $ - $ 750 $ 1,458 LNG - Plant Motor Control Center Strategic $ - $ 1,500 $ 6,000 LNG - Plant Regeneration Skid Strategic $ 2,500 $ 500 $ - LNG - Building Refurbishment Strategic $ 800 $ - $ - LNG - Electrical Distribution System Upgrade Project Strategic $ - $ 2,000 $ 4,000 LNG - Nitrogen Refrigeration Cycle Replacement Strategic $ 3,350 $ 9,000 $ 14,000 LNG - Plant Controls Instrumentation Upgrade Program Strategic $ 1,164 $ 4,112 $ 4,112 LNG - Spring Pipe Hanger and Pipe Support Replacement Program Strategic $ 1,000 $ 1,000 $ 1,000 LNG - Upgrade Plant Pneumatic Valve Operators Strategic $ 873 $ 873 $ 873 LNG - Plant Security Upgrade Program Strategic $ 850 $ 1,000 $ 1,000 Sub-Total $ 11,537 $ 20,735 $ 32,443 Tunnels Tunnels - Ravenswood Tunnel - Feeder Supports Strategic $ 1,976 $ 1,976 $ 1,976 Tunnels - Ravenswood Tunnel - NYF Gas Main Rollers Strategic $ 1,976 $ 1,976 $ 1,976 Tunnels - Asphalt Paving Strategic $ 81 $ - $ - Tunnels - Security Improvements Operationally Required $ 310 $ - $ - Tunnels - Steel Replacement Program Strategic $ 1,000 $ 1,000 $ 1,000 Tunnels - Annual Sump Pumps Strategic $ 75 $ 75 $ 75 Tunnels - Carbon Fiber Wrap Program Strategic $ 800 $ 800 $ 800 Tunnels - Astoria Elevator Modernization Operationally Required $ - $ 3,000 $ - Tunnels - 11th Street Elevator Modernization Operationally Required $ 3,000 $ - $ - Tunnels - Lighting Improvement Program Strategic $ 600 $ 600 $ 600 Tunnels - Concrete Restoration Program Operationally Required $ 500 $ - $ - Sub-Total $ 10,318 $ 9,427 $ 6,427 Meters Meter Purchases - New Business and Program Replacements Regulatory Required $ 10,354 $ 11,123 $ 11,572 Meter Installations - New Business and Program Replacements Regulatory Required $ 18,719 $ 18,623 $ 18,996 AMI Gas Detector Strategic $ 8,667 $ 17,313 $ 17,799 Sub-Total $ 37,740 $ 47,059 $ 48,367 Technical Operations Total $ 59,595 $ 77,221 $ 87,237 Gas Information Technology Gas Central Strategic $ 19,535 $ - $ - Leak Detection Equipment Strategic $ 560 $ 260 $ 20 Gas Information Technology Total $ 20,095 $ 260 $ 20 Security Improvements New Gas Control Room and LAN Room (CONFIDENTIAL*) Strategic $ - $ 3,000 $ 3,000 Tier 2 Security Improvements (CONFIDENTIAL*) Strategic $ 1,024 $ - $ - Security Improvements Total $ 1,024 $ 3,000 $ 3,000 Municipal Infrastructure Total $ 101,329 $ 109,344 $ 116,757 Grand Total $ 980,646 $ 987,644 $ 970,138 *Will be distributed pursuant to a protective order UPDATED EXHIBIT ___ (GIOSP-1) PAGE 4 of 157 TABLE OF CONTENTS WHITE PAPERS 1. DISTRIBUTION SYSTEM IMPROVEMENT PROGRAMS .................................... 6 I. DISTRIBUTION INTERGRITY: ........................................................................................... 7 Main Replacement Program ................................................................................................ 7 Distribution Integrity Main Enhancement ......................................................................... 10 Service Replacement Program .......................................................................................... 12 Large Diameter Gas Main Program .................................................................................. 14 Isolation Valves ................................................................................................................. 17 Optimain - Main Replacement Prioritization Software ..................................................... 19 II. SYSTEM RELIABILITY: ..................................................................................................... 21 Winter Load Relief ............................................................................................................ 21 Gas Reliability Improvement Program ............................................................................. 24 Regulator Station Revamps ............................................................................................... 26 Tarrytown-Ossining HP Tie .............................................................................................. 28 Ossining IP Upgrade to HP ............................................................................................... 30 Purchase Armonk High Pressure Tie ................................................................................ 32 Rehabilitation of the Gas Supply Main to City Island ...................................................... 34 2. TRANSMISSION PROGRAMS AND PROJECTS ................................................... 36 I. TRANSMISSION RISK REDUCTION AND RELIABILITY PROJECTS: ....................... 37 Remotely Operated Valves (ROVs) .................................................................................. 37 Transmission Main Leaks ................................................................................................. 39 Westchester / Bronx Border to White Plains..................................................................... 41 Newtown Creek Metering Station ..................................................................................... 44 Bronx River Tunnel to Bronx Westchester Border ........................................................... 46 Bronx River Tunnel and Easement ................................................................................... 49 Rye Gate Station Overpressure Protection ........................................................................ 52 Queens Transmission Upgrade (NESE approved) ...........................................................
Recommended publications
  • Trenchless for Gas Infrastructure 2020 Spring/Summer
    TRENCHLESS FOR GAS INFRASTRUCTURE 2020 SPRING/SUMMER World Record 42-Inch Gas Main CIPL Save Time. Make Money. TRY THE BET TER WAY TO BORE. Subsite HDD Guidance systems can improve the accuracy and efficiency of your bores. Our exclusive Green Ops™ process leverages modern data-sharing technology to give you a clear plan, more control, and faster reporting for safer, more productive jobs. Learn more at subsite.com and ask your Ditch Witch® dealer. © 2020 The Charles Machine Works, Inc. your single source for trenchless rehab & Replacement. HammerHead Trenchless provides precision-manufactured equipment, a comprehensive range of trenchless materials and supplies, and all the training and support you need to replace underground gas pipelines with minimal excavation. Offering only the best and most innovative trenchless technologies available in the gas industry, our responsive team is by your side throughout the life of your quality HammerHead equipment to ensure your success on every job. TOUGH EQUIPMENT. TRUSTED SUPPORT. visit hammerheadtrenchless.com or call 800.331.6653 PIPE BURSTING | PNEUMATIC PIERCING TOOLS | PIPE EXTRACTION | PIPE SLITTING ©2020 Charles Machine Works HG12_8.375x10.875-5.indd 1 3/6/2020 11:54:58 AM CONTENTS FEATURES: Chair – Babs Marquis 11 20 [email protected] Publication Advisor – George Ragula [email protected] PUBLISHER New World Record 42-Inch Direct Pipe® Installation under Gas Main CIPL the Calumet River 662 Dudley Avenue Records are made to be broken, and the world record Part of a multi-faceted project to retrofit a 36-inch Winnipeg, MB Canada CIPL in summer 2019 of a 42-Inch Cast Iron Gas Main steel gas transmission line in Chicago involved a R3M 1R8 in a complex layout buried under 8 lanes of the Garden record-setting 1500-foot installation under the State Parkway in East Orange NJ was a breakthrough Calumet River.
    [Show full text]
  • State of New York Public Service Commission Case 19
    STATE OF NEW YORK PUBLIC SERVICE COMMISSION CASE 19-E-0065 – Proceeding on Motion of the Commission as to the Rates, Charges, Rules and Regulations of Consolidated Edison Company of New York, Inc. for Electric Service. CASE 19-G-0066 – Proceeding on Motion of the Commission as to the Rates, Charges, Rules and Regulations of Consolidated Edison Company of New York, Inc. for Gas Service. JOINT PROPOSAL October 16, 2019 TABLE OF CONTENTS Page Procedural Setting ................................................................................................................2 Overall Framework ..............................................................................................................5 A. Term ...........................................................................................................................5 B. Rates and Revenue Levels ........................................................................................6 1. Electric ...............................................................................................................6 a. Supply and Supply-related Charges and Adjustments, Monthly Adjustment Clause and NYPA Surcharge ................................................6 b. Revenue Decoupling Mechanism (“RDM”) .............................................9 c. PJM OATT Charges ...............................................................................10 d. Other Charges .........................................................................................11 e. Tax Cuts and Jobs Act of 2017
    [Show full text]
  • Consolidated Edison Company of New York
    CONSOLIDATED EDISON COMPANY OF NEW YORK GAS OPERATIONS PANEL GAS TABLE OF CONTENTS Page CAPITAL EXPENDITURES .................................................................................................9 Operating Area Annual Capital Programs ...................................20 Supply Main Projects ...................................................................................37 Technical Operation Programs and Projects ...........................40 Transmission Projects and Programs ..........................................58 Gas Pressure Control Programs and Projects .........................72 Special Information Technology Projects .............................77 O&M EXPENDITURES ............................................................................................................86 DEFERRAL ACCOUNTING/RECONCILIATIONS ....................................................... 90 SAFETY PERFORMANCE MEASURES .................................................................................99 GAS OPERATIONS PANEL - GAS 1 Oo Would the members of the Gas Operations Panel please 2 state your names and business addresses? 3 Our names are Frank Ciminiello, Liliana Gonzalez, 4 Edward C. Foppiano, and Jyotin Thaker. Our business 5 addresses are 1615 Bronxdale Avenue, Bronx, New York, 6 10462 (for Ciminiello and Foppiano), 1560 Bruckner 7 Boulevard, Bronx, New York 10473 (for Gonzalez), and 8 315 Saw Mill River Road, Valhalla, New York 10595 (for 9 Thaker). I0 By whom are you employed and in what capacity? ii We are all employed
    [Show full text]
  • Letter Submitting Ten Copies of the 1999 Annual Report of Its Parent
    James S. Baumstark Vice President Nuclear Engineering Consolidated Edison Company of New York, Inc. Indian Point 2 Station Broadway & Bleakley Avenue Buchanan, New York 10511 Internet: [email protected] Telephone: (914) 734-5354 Cellular: (914) 391-9005 May 5, 2000 Pager: (917) 457-9698 Fax: (914) 734-5718 Re: Indian Point Unit No. 1 and No. 2 Docket No. 50-003 and 50-247 Document Control Desk US Nuclear Regulatory Commission Mail Station P1-137 Washington, DC 20555 In accordance with Section 50.7 1(b) of the Commission's regulations, Consolidated Edison Company of New York, Inc. submits herewith ten (10) copies of the 1999 Annual Report of its parent holding company, Consolidated Edison, Inc. Sincerely, cc: Mr. Hubert J. Miller Regional Administrator - Region I US Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. Jefferey F. Harold, Project Manager Project Directorate I- I Division of Reactor Projects I/II US Nuclear Regulatory Commission Mail Stop 14B-2 Washington, DC 20555 Senior Resident Inspector US Nuclear Regulatory Commission PO Box 38 Buchanan, NY 10511 •\ faort son-g on th raio orfl ale reain a eggk ahe lovg Wer thre bsies andi' a go statg fo life Contents To Our Shareholders : 2 Strategy : 6 Diversity: 10 Community: 14 The Environment: 18 Technology: 22 Corporate Policy Committee : 24 Financial Section : 25 To Our Shareholders The energy industry is going through a period of unprecedented change. While this change brings chal lenges, it also brings new potential and great opportunities. At Con Edison, we're taking advantage of the new dynamics in our industry to maximize our potential for future growth and strength.
    [Show full text]