13MS8011 POL Guide Standard Default 12/3/13 1:45 PM Page 1

Total Page:16

File Type:pdf, Size:1020Kb

13MS8011 POL Guide Standard Default 12/3/13 1:45 PM Page 1 13MS8011 POL Guide_Standard Default 12/3/13 1:45 PM Page 1 13MS8011 LABORATORY GUIDE 2013–2014 EDITION To Order: 1.800.P.SCHEIN (1.800.772.4346) 8am–9pm, et To Fax: 1.800.329.9109 24 Hrs JOIN OUR COMMUNITY www.henryschein.com/medical 13MS8011 POL Guide_Standard Default 12/3/13 1:09 PM Page 2 table of contents Henry Schein introduces the 2013/2014 Physician Office Lab Supply Guide. This guide is intended to serve as an overview of our most popular diagnostic testing options and supplies needed at the point of care. Don't see what you are looking for, ask your Sales Consultant. From rapid test kits to large analyzers, from CLIA waived to highly complex, we have POL solutions for all your needs. If you have questions regarding diagnostic, pharmaceutical, or vaccine items used in your practice, the DxRx Solutions Hotline is here to help! The DxRx Solutions Hotline can provide CPT Code, package inserts, CLIA product status, product storage requirements, and brand-to-generic comparisons. Let us help you today! DxRx Solutions Hotline 1-877-523-SHOT 8:30am – 5:00pm, ET [email protected] TABLE OF CONTENTS Respiratory ..................................................................5 General Chemistry and Lipids ......................................48 Strep A ..................................................................9-11 Coagulation................................................................49 Diabetes Management............................................12-18 Blood Collection ....................................................50-53 Kidney Function ..........................................................19 Lab Equipment ............................................................54 Urinalysis ..............................................................20-25 Lab Supplies ..........................................................55-57 Fecal Occult ..........................................................26-28 MOHs Lab Solutions....................................................58 Fecal Occult Immunochemical ................................29-30 Cytology/Histology Supplies ..................................60-61 Women's Health ..................................................31-34 Stains & Reagents ..................................................62-63 Infectious Disease Testing........................................35-39 Plated Media ..............................................................65 Drugs of Abuse Testing ..........................................40-41 Clinical Chemistry ..................................................66-81 Specialty Testing ....................................................42-46 Hematology ..........................................................82-85 Cardiac......................................................................47 Immunoassay ......................................................86-111 2 13MS8011 13MS8011 POL Guide_Standard Default 12/3/13 1:09 PM Page 3 diagnostics small package BIG REVOLUTION It will change the way you view rapid testing... New • Proven Performance vs PCR — • Results You Can Trust— PCR is currently the highest sensitivity Easy-to-read digital display eliminates standard available subjective interpretation • Reproducibility You Can Count On — • Convenient Workflow— Unique Adaptive Read Technology helps Testing requires minimal hands-on time reduce false-positive results Medical technology that captures the trusted answer BD Diagnostics www.bd.com/ds/veritorsystem 7 Loveton Circle Sparks, MD 21152-0999 BD, BD Logo and Veritor are property of Becton, Dickinson and Company ©2011 BD www.bd.com/ds To Order: 1.800.P.SCHEIN (1.800.772.4346) 8am–9pm, et • To Fax: 1.800.329.9109 24 Hrs 13MS8011 www.henryschein.com/medical 3 13MS8011 POL Guide_Standard Default 12/3/13 1:09 PM Page 4 respiratory THE ONESTEP LINE OF DIAGNOSTIC TESTS FEATURES SUPERIOR CLINICAL PERFORMANCE, ACCURACY, AND QUICK RESULTS LOOK WHAT’S BEEN ADDED TO THE HENRY SCHEIN ONESTEP+ INFLUENZA A & B TEST OneStep+ Influenza A & B Test This test provides a simple, rapid method to aid in the differential diagnosis of influenza A & B using nasal swab specimens. • CLIA Waived • 10-minute results • Sensitivity (A/B): 93.8%/77.4% • Specificity (A/B): 95.8%/98% (112-6219).....................................................25/box CPT® Codes: Influenza A: 87804QW†; Influenza B: 87804-59† Serving you Quality, Selection and Performance. It’s our promise to you. 4 13MS8011 13MS8011 POL Guide_Standard Default 12/3/13 1:09 PM Page 5 respiratory ONESTEP+ INFLUENZA A & B TEST This test provides a simple, rapid method to aid in the differential diagnosis of influenza A & B using nasal swab specimens. • CLIA Waived BD Veritor™ System • 10-minute results A rapid chromatographic • Sensitivity (A/B): 93.8%/77.4% immunoassay for use • Specificity (A/B): 95.8%/98% with symptomatic patients. #1126219, Influenza A & B Test NEW! This CLIA-waived kit is to (112-6219) .........................................25/box be used with the BD Veritor CPT® Codes: 87804QW† (Influenza A); System Reader to test nasal and 87804-59† (Influenza B) nasopharyngeal swab samples that are freshly collected, processed and dispensed directly onto an assay test device. • Proven performance vs. PCR • Unique Adaptive Read Technology provides reproducibility you can count on • Easy-to-read digital display eliminates subjective interpretation and delivers the “Trusted Answer” QuickVue® Influenza Tests • Convenient workflow with minimal An immunoassay for detecting influenza hands-on time types A and B. Three simple steps with #256055, BD Veritor™ System Reader results in 10 minutes or less. Color-coded (992-0003) ................................................ea procedure card helps demonstrate each #256045, CLIA-waived BD Veritor™ System step of test. Kit contains positive and Flu A+B Kit negative controls, and stores at room temperature. (992-0002).................................30 tests/pkg • Detects both A and B types of influenza CPT® Codes: Influenza A: 87804QW† / Influenza B: • CLIA waived 87804-59†; Using the Objective and Differentiated Reader System: 87999† • Sensitivity (A/B): 94%/70% • Specificity (A/B): 90%/97% • Color-coded procedure card helps demonstrate each step of the test #00317, Non-differential • No instrumentation needed (227-9012) .........................................25/box • Results in 10 minutes or less, right in the #20103, Swab Pack* with 25 Individually exam room Pouched Sterile Foam Swabs • Room-temperature storage with up to a (986-3022) .........................................25/pkg 24-month shelf life from date of manufacture #20171, Transport Tubes* with 25 • Made in the USA Sterile Foam Swabs Inside Plastic Transport Tubes #20183, A+B Test, Differentiates Type A or (227-3550) .........................................25/box Type B CPT® Codes: Influenza A, 87804QW†/ (227-5611) .........................................25/box Influenza B, 87804-59† BinaxNOW® Influenza A & B Tests Rapid test for identification and differentiation of influenza A and B, using specimen collected by nasal washes/aspirates, nasal swabs and nasopharyngeal swabs. • CLIA waived • Differentiates types A and B on the same card OSOM® Influenza A & B Tests • Sensitivity (A/B): 70–89%/50–69% • Specificity (A/B): 90–99%/94–100% In vitro diagnostic test for the qualitative • Easy to use: no additional detection of influenza A and B antigens. reagents needed • Differentiates between influenza A and B • On-board extraction • Sensitivity (A/B): 73.8%/60% • 15-minute results • Specificity (A/B): 96.4%/96.4% • Same specimen can be used with • Easy to read: 3 distinct lines BinaxNOW® RSV test • Nasal swab specimens • Made in the USA • Less than 1 minute hands-on time; results in 10 minutes #416-022 #190 • Room-temperature storage (106-3126) .........................................27/box (153-9781) .........................................22/box • Moderately complex #416-110 • 2 extra test sticks included for external #191, Influenza A & B Control Kit (348-7480) .........................................10/box QC testing (106-3132) ................................................ea CPT® Codes: Influenza A: 87804QW†/Influenza B: • Made in the USA CPT® Codes: Influenza A and B, 87804-59† 87804-59† To Order: 1.800.P.SCHEIN (1.800.772.4346) 8am–9pm, et • To Fax: 1.800.329.9109 24 Hrs 13MS8011 www.henryschein.com/medical 5 13MS8011 POL Guide_Standard Default 12/3/13 1:10 PM Page 6 respiratory 6 13MS8011 13MS8011 POL Guide_Standard Default 12/3/13 1:10 PM Page 7 respiratory BinaxNOW® RSV Tests • CLIA waived • Easy to use: no additional reagents needed • On-board extraction • 15-minute results • Built-in control to ensure accuracy • Same specimen can be used with BinaxNOW Influenza A & B Test BinaxNOW® S. • Made in the USA pneumoniae Urinary #430-100, Test Antigen Test (301-8899) .........................................10/box An in vitro rapid immunochromatographic #430-122, Test assay for the qualitative detection of (512-5059) .........................................22/box S. pneumoniae ® antigen in the urine CPT Code: 87807QW† of patients with pneumonia and in the cerebral spinal fluid (CSF) of patients with meningitis. In conjunction with culture and other methods, it is intended to aid in the diagnosis of both pneumococcal pneumonia and pneumococcal meningitis. • Dependable accuracy • Accuracy/sensitivity: urine: 86% sensitivity/94% specificity; CSF: 97% Clearview® RSV Test sensitivity/99% specificity A 15-minute, four-step
Recommended publications
  • OSPE Renal Micro AA
    MICROBIOLOGY PRACTICAL TEAMWORK 437 URINARY TRACT INFECTION Objectives: 1- Know the important steps in specimen collection and transport to the lab. 2-How to process urine Specimens in the lab. – Urine microbiological and biochemical analysis. – Organisms culture and identification. – Antibiotic susceptibility testing. – Results interoperation. 3- Know the clinically important etiological Organisms associated with UTI, their identification and susceptibility testing. Done by : ABEER ALABDULJABBAR NOURA ALOTHAIM OMAR ALSUHAIBANI Important aspects of Microbiologic Examination of UTI SPECIMEN COLLECTION : -Urine collection SPECIMEN PROCESSING : -Urine analysis -Urine culture -Interpretation of microbiology -laboratory result 1- SPECIMEN COLLECTION Type of specimens Midstream urine (MSU): best for adult The urine collected in a wide mouthed container from patients a mid stream specimen is the most ideal for processing Female patients pass urine with a labia separated and mid stream sample is collected Adhesive bag best for child Suprapubic aspiration Catheter sample: (used with elderly) Urine specimens for laboratory investigations can be collected from catheterized patients as shown (left). The second port is for putting fluids into the bladder (right). Urine from the drainage bag should not be tested because it may have been standing for several hours. TRANSPORT MEDIA -Sterile urine container -Dip slide (one side is CLED media and the other is MacConkey agar or blood agar) 2- SPECIMEN PROCESSING B-Culture and C-Antimicrobial A-Urine analysis identification Susceptibility D-Results (ID) testing interpretation • Microbiological Disk diffusion Culture media test Macroscopic Urine inoculation and E test Microscopic reading of culture Biochemical Identification of cultured organisms A-Urine analysis v Biochemical : Biochemical Urine Examination (Dip stick) Testing for UTI : Midstream clean catch with dipstick analysis Dipstick results may be affected by medications/dyes, i.e.
    [Show full text]
  • Product List 2006
    94474 Product COVER 5/12/05 6:09 pm Page 1 [email protected] Данный документ является собственностью компании "СИМАС" www.simas.ru Product List 2006 т.ф. (495) 980-29-37, 781-21-58, 319-22-78, 311-22-09 Oxoid Price List 2006 International Orders UK Orders International Customer Services UK Customer Services Oxoid Limited Oxoid Limited Wade Road Wade Road Basingstoke Basingstoke Hampshire RG24 8PW Hampshire RG24 8PW UK Telephone: 01256 816566 Telephone: +44 (0) 1256 841144 Facsimile: 01256 334994 Facsimile: +44 (0) 1256 463388 e-mail: [email protected] e-mail: [email protected] Web: www.oxoid.com Web: www.oxoid.com Technical Support Helpline Technical Support Helpline Telephone: 01256 694281 Telephone: +44 (0) 1256 694287 Facsimile: 01256 329728 Facsimile: +44 (0) 1256 329728 e-mail: [email protected] e-mail: [email protected] For details of your local Oxoid distributor Telephone: +44 (0) 1256 694347 Facsimile: +44 (0) 1256 329728 www.oxoid.com ForFor.b:w9cee(e-bb@+5.b@b-wi,b9b@b-wlP Conditions of Sm9@Fb@@ndibil: [email protected] ec’ F,w.oph.:Support +5.b:xoi. +ee(e-bb@ 94474 Product Text 3/12/05 9:31 am Page 1 [email protected] Данный документ является собственностью компании "СИМАС" www.simas.ru Contents PAGE PAGE ❐ Important Information 2 ❐ AST 25 ❐ Products by Organism 3 Aura System 25 ❐ Worldwide Distributors 6 Disc Dispensers 25 Discs 28 ❐ Prepared Media 21 Diagnostic Discs 28 Dip Slides 21 ❐ Ready Bags 22 ID Biochemical Tests 29 Prepared Media 22 Microbact 29 Biochemical Reagents 28 OBIS Kits 28 ❐ Culture Media 9 Touch Sticks
    [Show full text]
  • OXOID MANUAL PRELIMS 16/6/06 12:18 Pm Page 1
    OXOID MANUAL PRELIMS 16/6/06 12:18 pm Page 1 The OXOID MANUAL 9th Edition 2006 Compiled by E. Y. Bridson (substantially revised) (former Technical Director of Oxoid) Price: £50 OXOID MANUAL PRELIMS 16/6/06 12:18 pm Page 2 The OXOID MANUAL 9th Edition 2006 Compiled by E. Y. Bridson (substantially revised) (former Technical Director of Oxoid) 9th Edition 2006 Published by OXOID Limited, Wade Road, Basingstoke, Hampshire RG24 8PW, England Telephone National: 01256 841144 International: +44 1256 841144 Email: [email protected] Facsimile National: 01256 463388 International: +44 1256 463388 Website http://www.oxoid.com OXOID SUBSIDIARIES AROUND THE WORLD AUSTRALIA DENMARK NEW ZEALAND Oxoid Australia Pty Ltd Oxoid A/S Oxoid NZ Ltd 20 Dalgleish Street Lunikvej 28 3 Atlas Place Thebarton, Adelaide DK-2670 Greve, Denmark Mairangi Bay South Australia 5031, Australia Tel: 45 44 97 97 35 Auckland 1333, New Zealand Tel: 618 8238 9000 or Fax: 45 44 97 97 45 Tel: 00 64 9 478 0522 Tel: 1 800 331163 Toll Free Email: [email protected] NORWAY Fax: 618 8238 9060 or FRANCE Oxoid AS Fax: 1 800 007054 Toll Free Oxoid s.a. Nils Hansen vei 2, 3 etg Email: [email protected] 6 Route de Paisy BP13 0667 Oslo BELGIUM 69571 Dardilly Cedex, France PB 6490 Etterstad, 0606 Oxoid N.V./S.A. Tel: 33 4 72 52 33 70 Oslo, Norway Industriepark, 4E Fax: 33 4 78 66 03 76 Tel: 47 23 03 9690 B-9031 Drongen, Belgium Email: [email protected] Fax: 47 23 09 96 99 Tel: 32 9 2811220 Email: [email protected] GERMANY Fax: 32 9 2811223 Oxoid GmbH SPAIN Email: [email protected] Postfach 10 07 53 Oxoid S.A.
    [Show full text]
  • Microbiology Program –Medical Faculty (5-Y
    MICROBIOLOGY PROGRAM – Medicine Faculty 2020/2021 Didactic hours: Seminars: 36 hrs, practical classes: 34 hrs S1. Basics of medical bacteriology: morphology of bacteria. Procaryotic cell structure: capsule, flagella, fimbriae, cell wall, cell membrane, LPS, cytoplasm components; spores. Morphology of bacteria: bacterial cell (structure, dimensions, shapes, arrangements – cocci, rods (bacilli), spirochetes. Differential characteristics of bacteria: differences of bacterial cell wall structure: Gram- positive, Gram negative -negative bacteria, mycobacteria. Classification of microorganisms: kingdom, phylum, class, order, family, genus, species (strain, biotype, serotype, serovar). Direct detection of bacteria: bacterial cell detection (microscopy; smears), bacterial component (antigen) detection in the specimen sample (serology) genetic material detection (molecular techniques). Types of slide preparation - unstained (wet mount) slide preparation, stained smear; direct smear, smear from culture. Types of microscopes: bright-field light microscopy, dark-field microscopy, fluorescent microscopy. Staining techniques and application: simple and differential staining, positive and negative staining; staining types: Gram staining, Ziehl-Neelsen (acid –fast) staining , Neisser staining, Giemsa staining, Loeffler staining. Major groups of Gram-positive bacteria – cocci: Staphylococcus, Streptococcus, Enterococcus; bacilli: Bacillus, Clostridium; Corynebacterium, Listeria, Lactobacillus, Mycobacterium, Nocardia, Actinomyces. Major groups of Gram-negative
    [Show full text]
  • Microbiologically-Influenced Corrosion (MIC) Or Biocorrosion
    MICROBIALLY INFLUENCED CORROSION OF INDUSTRIAL MATERIALS - BIOCORROSION NETWORK - (Brite-Euram III Thematic Network N° ERB BRRT-CT98-5084 Biocorrosion 00-02 Simple methods for the investigation of of the role of biofilms in corrosion September 2000 Task 1: Biofilms Publication by Iwona Beech, Alain Bergel, Alfonso Mollica, Hans-Curt Flemming (Task Leader), Vittoria Scotto and Wolfgang Sand SIMPLE METHODS FOR THE INVESTIGATION OF THE ROLE OF BIOFILMS IN CORROSION BRITE EURAM THEMATIC NETWORK ON MIC OF INDUSTRIAL MATERIALS TASK GROUP 1 BIOFILM FUNDAMENTALS IWONA BEECH ALAIN BERGEL ALFONSO MOLLICA HANS-CURT FLEMMING (TASK LEADER) VITTORIA SCOTTO WOLFGANG SAND 1 CONTENTS 1 MICROBIOLOGICAL FUNDAMENTALS 1.1 WHAT IS MIC? 1.2 PRINCIPLES OF MICROBIAL LIFE 1.3 SOME DETAILS OF MICROBIAL LIFE 1.4 MICROORGANISMS INVOLVED IN MIC 2 MICROBIOLOGICAL INVESTIGATION OF MIC 2.1 LIQUID SAMPLES 2.2 SOLID SAMPLES 2.3 PRE-TREATMENT OF SAMPLES 2.4 DETECTION AND IDENTIFICATION OF MICROORGANISMS 2.4.1 MICROSCOPICAL EXAMINATION 2.4.2 RAPID DETECTION 3 A GUIDE TO SIMPLE METHODS TO ASSESS THE PRESENCE OF BIOFILMS IN FIELD AND THE MIC RISK 3.1 INTRODUCTION 3.2 METHODS FOR BIOFILM EVALUATION 3.2.1 CARBOHYDRATE ANALYSIS 3.2.1.2 PROTEIN ANALYSIS 3.3.1 IS THE BIOFIL M COMPOSED OF OXYGEN PRODUCERS OR OXYGEN CONSUMERS? 3.4 THE CORROSION POTENTIAL MEASUREMENT: A TOOL FOR EVALUATING THE MIC RISK 2 1 MICROBIOLOGICAL FUNDAMENTALS Iwona Beech and Hans-Curt Flemming 1.1 What is MIC? MIC is the acronym for “Microbally Influenced Corrosion”. It refers to the possibility that microorganisms are involved in the deterioration of metallic (as well as non-metallic) materials.
    [Show full text]
  • European Urinalysis Guidelines SUMMARY
    Scand J Clin Lab Invest 2000; 60: 1 ± 96 European Urinalysis Guidelines SUMMARY These European Urinalysis Guidelines are given Classi®cation of examiniations under the auspices of the European Confedera- Examinations have been re-classi®ed into four tion of Laboratory Medicine (ECLM). hierarchical levels based on accuracy of mea- surements (chemistry on Page 12, particle Medical needs for urinalysis analysis on Page 23, microbiology on Page Urinalysis should always be performed on the 31). In addition, the previous literature on the basis of medical need, and appropriate exam- visual appearance and odour of urine is inations for various clinical populations and presented (Page 13). presentations should be determined by cost/ bene®t analysis. On this basis, selection indica- Chemical methods of examination tions for urinalysis are suggested for detecting Principles and performance criteria of multiple diseases of the kidneys or urinary tract (Page 6). test strips are reviewed (Page 13). A nitrite test The referral for detailed urine examinations should not be used alone in detecting urinary should include an adequate description of the tract infections because of its low sensitivity. specimen type, and should inform the labora- Quali®ed procedures for measurement are tory of the clinical need in order to facilitate recommended (Page 56). Pregnancy examina- correct selection of examination procedures and tions are reviewed brie¯y (Page 18). interpretation of results (Page 6). This medical Quantitative chemical measurements are dis- information is mandatory when the choice is cussed in detail, mainly with respect to protein being made between minimum and optimum measurements (Page 18). Measurements asses- procedures for different specimens.
    [Show full text]
  • Point-Of-Care Testing for Urinary Tract Infections Horizon Scan Report 0045 June 2016
    Diagnostic Evidence Co-operative Oxford Point-of-care testing for urinary tract infections Horizon Scan Report 0045 June 2016 Clinical Question: In diagnosing patients with suspected urinary tract infections, what is the accuracy and utility of point-of- care tests compared to the current standard of urine microscopy, culture and antibiotic sensitivity analysis? Background, Current Practice and Advantages over Existing Technology: Background Urinary tract infections (UTIs) are among the most common types of infections, with an estimated 92 million people affected worldwide in 2013.1 The global burden of this disease is rising, with 16.1% increase in age- standardised incidence between 1990 and 2013 and 58,000 years lost to disability (YLD) in 2003 alone.1 UTIs are also a significant cause of mortality especially among the elderly population with 4835 deaths in England and Wales reported in 2012.2 UTI symptoms accounted for 1-3% of all primary care consultations3 and it was the main indication for 13.7% of community antibiotic prescriptions.4 The 1994/5 cost estimates of treating UTIs in the National Health Service were £124 million.5 Two decades on, it can only be assumed that with the rising prevalence of UTIs combined with the emergence of antibiotic-resistant organisms, the health and economic burden of the disease is likely to have increased. UTIs are broadly defined as infection of the urethra, bladder, ureters or kidneys by non-commensal micro- organisms, most commonly Escherichia coli, Staphylococcus saprophyticus and Enterococcus faecalis.6 Other causative uropathogens include Enterobacteriaceae sp. (Proteus mirabilis and Klebsiella sp.), group B streptococci, Pseudomonas aeruginosa, and Citrobacter sp.
    [Show full text]
  • READY-TO-USE DIPSLIDE MEDIA DA-212115.03 Rev.: Aug 2005
    INSTRUCTIONS FOR USE – READY-TO-USE DIPSLIDE MEDIA DA-212115.03 Rev.: Aug 2005 BD™ BBL UROTUBE • BBL UROTUBE M • BBL UROTUBE E • BBL UROTUBE E. coli • BBL UROTUBE SXT INTENDED USE BBL UROTUBE products are dipslides used for the isolation and determination of the colony count of microorganisms isolated from urine specimens. The surfaces of the dipslides are coated with two or three different culture media. All BBL UROTUBE products contain CLED Agar for the determination of the total count of bacteria and/or yeasts, and MacConkey Agar for the detection of Gram negative bacteria, e.g., Enterobacteriaceae. The third medium, if available, is dependent on the respective product. PRINCIPLES AND EXPLANATION OF THE PROCEDURE Microbiological method. Dipslides are widely used today as a screening technique for the enumeration and isolation of microorganisms from routine urine specimens.1-5 After the dipslide is immersed into a properly collected fresh urine specimen and the slide is subsequently incubated, the colony number on the surface of CLED Agar is compared to a reference picture. CLED Agar was developed by Sandys in 1960 to prevent the swarming of Proteus by restricting the electrolytes in the culture medium which was modified later several times for use in urine culture.6 It was designated as Cystine-Lactose-Electrolyte-Deficient (CLED) medium and reported to be ideal for dip-inoculum techniques and for urinary bacteriology in general.6,7 The nutrients in CLED Agar are supplied by the gelatin and casein peptones, and beef extract. Lactose is included to provide an energy source for organisms capable of utilizing it by a fermentative mechanism.
    [Show full text]
  • Laboratory Manual of Microbiology
    Laboratory Manual of Microbiology Laboratory Manual of Microbiology Vivek Kumar Microbiology Section, Department of Soil and Water Research, Plant Wealth Sector, Public Authority of Agriculture and Fish Recourses, State of Kuwait Published by: Scientific Publishers (India) 5-A, New Pali Road, P.O. Box 91, Jodhpur – 342 001 (India) E-mail: [email protected] www.scientificpub.com © Scientific Publishers (India), 2011 All rights reserved. No part of this publication or the information contained herein may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, by photocopying, recording or otherwise, without written prior permission from the editor and the publishers. ISBN: 978-81-7233-706-3 (HB) 978-81-7233-707-0 (PB) Lasertype set : Rajesh Ojha Printed in India PREFACE The rapid expansion of microbiology has lad to proliferation of technical methods. This laboratory manual of microbiology is an attempt to form a comprehensive reference source for a common microbiologist. The manual is aimed at the graduate and advanced student and the research worker who studies or uses micro- organisms. Each exercise has been designed to be modular and with brevity. The exercises have also been designed to use commonly available microbiological tools and instruments to complete in short time period. This laboratory manual of microbiology has been written to meet the needs of students taking microbiology as major or subsid- iary subject. The intention is to provide the student with an organi- zed, user-friendly tool to better enable him or her to understand laboratory aspects of microbiology as well as to hopefully make learning laboratory material and preparing for independent player of a given experiment.
    [Show full text]
  • LIOFILCHEM® S.R.L
    Liofilchem® Product Catalogue 2019 Clinical and Industrial Microbiology ® ! Microbiology Products Est. 1983 MICROPLANET MICROPLANET 2 In memory of Dr. Santa Ruggieri 1962-2011 MICROPLANET 3 Visit www.liofilchem.com to be up to date with our product updates, latest news, special offers and information on products and services. The Liofilchem website offers a convenient and eco-friendly complete on-line Product Catalogue, fliers, brochures and video featured product pages. Liofilchem Quality Control Certificates, Technical Sheets, MSDS and much more are available for download at the on-line Technical Library." TheMICROPLANET Liofilchem on-line technical documentation service is convenient, quick and available 24/7. 4 LIOFILCHEM® s.r.l. Via Scozia, Zona Industriale 64026 Roseto degli Abruzzi (Te) Italy Tel.: +39 0858930745 Fax: +39 0858930330 www.liofilchem.com Since 1983 Liofilchem® s.r.l. has committed its Research and Development department to the production of reliable and high quality bacteriology products. Our dedication to Customer satisfaction and exceptional manufacturing versatility have granted Liofilchem® continuous growth, as a result of the increasing quality of our products and the worldwide distribution of the Liofilchem® brand name. Liofilchem® is present in over 130 countries with agents and distributors placing our products in clinical and industrial laboratories around the world. Our catalogue is comprised of approximately 6000 items basically classified into two main categories, clinical and industrial microbiology. Liofilchem® manufacturing
    [Show full text]
  • Practical UTI
    Lecture : Practical UTI important Extra notes "ﻻ ﺣول وﻻ ﻗوة إﻻ ﺑﺎ@ اﻟﻌﻠﻲ اﻟﻌظﯾم" وﺗﻘﺎل ھذه اﻟﺟﻣﻠﺔ إذا داھم اﻹﻧﺳﺎن أﻣر ﻋظﯾم ﻻ notes Doctors ﯾﺳﺗطﯾﻌﮫ ، أو ﯾﺻﻌب ﻋﻠﯾﮫ اﻟﻘﯾﺎم ﺑﮫ . Objectives: 1- to Know the important steps in specimen collection and transport to the lab. 2. How to process urine Specimens in the lab. – Urine microbiological and biochemical analysis. – Organisms culture and identification. – Antibiotic susceptibilitytesting. – Results interoperation. 3. Know the clinically important etiological Organisms associated with UTI, their identification and susceptibility testing. • اﻟﻌﻣل ﻣﻌﺗﻣد و ﺷﺎﻣل ﻋﻠﻰ ﻣﺣﺎﺿرات اﻟدﻛﺎﺗرة : Overview • ﻻ ﺗﺧﺎﻓون ﻣن ﻋدد اﻟﺳﻼﯾدز , اﻟﺳﻼﯾدز ﺧﻔﯾﻔﺔ و ﻏﺎﻟﺑﯾﺔ اﻟﻣﻌﻠوﻣﺎت ﻣﻌروﻓﺔ وﺳﮭﻠﺔ اﻟﻣﺣﺎﺿرة ﺗﺗﻛﻠم ﻋن أرﺑﻊ ﻣﺣﺎور أﺳﺎﺳﯾﺔ : إن ﺷﺎء ﷲ collecting urine 1- • ﻓﻲ ﻧﮭﺎﯾﺔ اﻟﻣﺣﺎﺿرة ﻓﯾﮫ ﻛﯾﺳﯾز ﻣن ﺳﻼﯾد اﻟدﻛﺎﺗرة , ﻟﻛن اﻟﺣل ﻣن اﻟﺗﯾم analysis urine 2- • رﻛزوا ﻋﻠﻰ .. groth + stain + culture their and microorganism microorganisms the 3- (وﺑﺎﻟﺗوﻓﯾﯾق اﺟﻣﻌﯾﯾن) Testing Susceptibility Antimicrobial 4- Important aspects of Microbiologic Examination of UTI: • Urine collection • Urine analysis • Interpretation of microbiology • laboratory result 1- Urine collection Midstream urine (MSU): • The urine collected in a wide mouthed container from patients a mid stream specimen is the most ideal for processing • Female patients pass urine with a labia separated and mid stream sample is collected Adhesive bag Types of specimens: Suprapubic aspiration (for children) Clean catch Catheter sample: (used with elderly) • Urine specimens for laboratory investigations can be collected from catheterized patients as shown (left). The second port is for putting fluids into the bladder (right). • Urine from the drainage bag should not be tested because it may have been standing for several hours.
    [Show full text]
  • 1 Methicillin-Resistant Staphylococcus Aureus On
    Methicillin-Resistant Staphylococcus aureus on Public Transportation Vehicles: Sampler Performance, Prevalence, and Epidemiology DISSERTATION Presented in Partial Fulfillment of the Requirements for the Degree Doctor of Philosophy in the Graduate School of The Ohio State University By Jonathan Kyle Lutz, M.P.H. Graduate Program in Public Health The Ohio State University 2011 Dissertation Committee: J. Mac Crawford, Advisor Armando E.S. Hoet Jiyoung Lee John R. Wilkins III 1 Copyright by Jonathan Kyle Lutz 2011 i Abstract Methicillin-resistant Staphylococcus aureus (MRSA) is an important public health threat, with significant disease burden. Of particular concern are the growing number of cases that have origins in the community (CA-MRSA); these infections often affect individuals without underlying risk factors for disease. Because MRSA colonizes a large number of people, can be easily spread by fomites, and survives on surfaces for months, the environment is an important element in MRSA transmission. Public transportation vehicles, which have high levels of crowding and significant hand-to-fomite contact, may represent an important site for MRSA transmission. This study determined the background prevalence of MRSA on buses from a large transportation agency. Prior to vehicle sampling, a laboratory-based study was conducted to evaluate the performance of four sampling methods for recovery of S. aureus from a stainless steel surface. Results indicate that overall, the electrostatic wipe resulted in the greatest performance across all inoculating concentrations ([relative sampling efficiency=SE; 2 analytical sensitivity=Sn] SE48h=17.8%; Sn48h=7 CFU/100cm ). However, the swab sampler performed well when corrected for area actually sampled (SE48h=24.3%; 2 Sn48h=76 CFU/100cm ), but is greatly limited by the surface area which can be effectively sampled.
    [Show full text]