Fundamentals of Kitchen Ventilation
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Article 5A. Mechanical Code
ARTICLE 5A. MECHANICAL CODE 4-5a01. UNIFORM MECHANICAL CODE INCORPORATED. The Uniform Mechanical Code, 1997 edition, including Appendix A, prepared and published by the International Conference of Building Officials, 5360 Workman Mill Road, Whittier, California 90601-2298 is hereby adopted and incorporated by reference as authorized by K.S.A. 12-3009 to 12-3012 inclusive, for the purpose of establishing rules and regulations for mechanical systems installed or modified in the city and jurisdiction thereof, except as otherwise provided in this article. Not less than three copies of the Uniform Mechanical Code, 1997, shall be marked or stamped “Official Copy as Incorporated by the Code of the City of Ulysses,” and shall be filed with the city clerk to be open for inspection and available to the public at all reasonable hours. Persons charged with the enforcement of this code shall be supplied copies at the cost of the city. (Ord. 1025, Sec. 1) 4-5a02. PERMIT FEES. Table 1A of the Uniform Mechanical Code is amended by deleting the original language and substituting the following: (a) For the issuance of each permit - $5; (b) For the installation or relocation of each forced-air or gravity- type furnace or burner, including ducts and vents attached to such appliance, up to and including 10,000 BTU's - $6; (c) For the installation or relocation of each floor furnace, including vent; or each suspended heater, recessed wall heater or floor mounted unit heater - $6; (d) For the installation, relocation or replacement of each appliance vent installed -
Fantech Ventilation Solutions Guide
Ventilation Solutions Edition 2019-2021 Welcome to Fantech This year we launch a new era of the Fantech product Bouctouche, Canada catalog. Redesigned and rethought, the printed book you hold in your hands along with future marketing materials are moving in a new direction inspired by our vision to become your best friend in HVAC. In that spirit, this edition is dedicated to finding unique solutions to help make your work shine. This edition is focused on product applications and how our products can be a win-win solution to various challenges that you face in your day-to-day work. On pages to follow, we packaged core products with accessories that allow you to complete your job all in one go. Included in this catalog are more application renderings than ever before. Visualization of our products in action has helped our customers see the versatility and value in using Fantech equipment in a variety of applications to increase Indoor Air Quality. Skinnskatteberg, Sweden This catalog is designed to help you see your job with a different set of eyes. After all, Fantech's most important eyes on a project are yours. Lenexa, Kansas Index Products by Family Featured Product Accessories CM/DM HEPA Filtration Unit .....................................................100 ECO-Touch .........................................................................................93 CVS Multiport Exhaust Fan ..........................................................24 Hoodliner .............................................................................................93 -
Commercial Kitchen Hood Worksheet / Checklist
TAYLOR BUILDING / ZONING DEPARTMENT 425 Papermill Rd. - P.O. Box 158 Taylor AZ. 85937 Phone (928) 536-7366 COMMERCIAL KITCHEN HOOD WORKSHEET / CHECKLIST Two copies of this worksheet / checklist must accompany plan sets submitted with commercial kitchen range hood permit applications. It explains and organizes information needed by the Building Department to efficiently review plans and issue permits. The applicant is responsible for assuring the accuracy and consistency of the information. A. Project Address:___________________________________________________________________ B. Established use and history of building: Is it an existing restaurant, food processing area or food service area: Yes No C. Location of exterior ductwork and mechanical equipment: 1. Is ductwork or mechanical equipment located outside of building other than roof top? Yes No 2. Applicant shall provide plan and elevation views showing ductwork, duct enclosure, hood, cooking surface air supply, exhaust system, and equipment support including structural detail (See attached examples 1,2 and 3). D. Type of hood: (507.2) 1. For grease and smoke removal: Type I ______Quantity (Example: Deep fryer, char-broilers, grill, pizza ovens and all solid-fuel appliances) 2. For steam, vapor, heat or odor removal: Type II ______Quantity (Example: steamer, pastry dishwashers) Hood shall have a permanent, visible label identifying it as a Type II hood. 3. Is hood for solid-fuel cooking equipment? Yes No If yes, a separate exhaust system is required. E. Type of material and gage (506.3.1.1, 507.4, 507.5) TYPE I HOOD TYPE II HOOD Gage Gage Type of Material Min. Req. Proposed Min. Req. Proposed Duct and Stainless Steel 18 Ga. -
Commercial Kitchen Ventilation- Efficient Exhaust and Heat Recovery
#331-1 CH-89-9-6 Commercial Kitchen Ventilation Efficient Exhaust and Heat Recovery D.K. Black ASHRAE Life Member ABSTRACT ciency and, if it malfunctions, can shut down the entire This paper outlines those considerations and kitchen and restaurant. requirements that are pertinent to the design and opera The subject of commercial kitchen ventilation covers tion of a properly functioning exhaust system 'for a a number of factors or considerations that combine to form commercial kitchen. It embraces such subjects as air the basis of a system that will perform satisfactorily, be cost quality, energy conservation, air pollution control, sanita effective, and comply with applicable codes. tion, and fire safety. Determination of necessary and These factors include smoke capture, grease extrac appropriate exhaust air volumes for various items of cobk· tion and disposal, fire protec1ion. and the maintenance of ing equipment is discussed. The potential for heat acceptable air quality and temperature in the kitchen recovery Is detailed, together with a description of the space. Modern systems may also include air pollutioh con technology involved. trol and heat recovery equipment. Efficient grease extraction is extremely important. INTRODUCTION Grease that is hOt exhausted will collect in ductwork and The state of the art in commercial kitchen ventilation create a fire hazard. To such areas, the difference between is indeed essentially an art, accepting certain basic funda 90% and 95% efficiency is not 5% but rather 100%. mentals of thermodynamics, environmental control, and air Centrifugal ~rease extraction has proved to be highly movement, but responding largely to experience and effective and is currently employed on most leading logic. -
Download PDF Catalog
When Time Matters! ANTI-POLLUTION ECOLOGICAL SYSTEM I The FAST ecological system was designed to meet all types of commercial kitchen installations. The ecological system is an environmentally-friendly solution that helps maintain air quality. The main objective of the ecological system is to extract the maximum amount of grease in the air emanating from the kitchen hood, to then vent it through the exhaust system and out of the building. Installing an ecological system also has several other advantages: • The filtered air from the system can be vented to the outside of the building at ground level, generating substantial savings by eliminating the use of a fully welded duct all the way to roof level. • A fully welded duct between the hood and the filtration section in accordance with NFPA96 and a standard duct as per the National Building Code of Canada between the filtration section and the outside of the building. • 99 % of all grease and smoke from the kitchen hood is extracted by the ecological device. • Fire risk is greatly reduced. • Acceptable reduction of cooking odours emanating from the hood. • The entire unit can be installed in the kitchen ceiling, a service room or on the roof. • Can be installed in a multi-restaurant project such as a food court. • Can be installed in a heritage building or a building with a specific architecture. • listed • The exterior finish of the unit is stainless steel. 2-i Product improvement is an ongoing policy at FAST. Slight modifications may be made to technical specifications without prior notice. Please contact us for immediate assistance. -
Kitchen Ventilation Improvement
Kitchen Ventilation Improvement Course No: M01-003 Credit: 1 PDH Steven Liescheidt, P.E., CCS, CCPR Continuing Education and Development, Inc. 22 Stonewall Court Woodcliff Lake, NJ 07677 P: (877) 322-5800 [email protected] Design Guide Improving Commercial Kitchen Ventilation System Performance This design guide provides informa- tion that will help achieve optimum Introduction performance and energy efficiency in An effective commercial kitchen ventilation (CKV) system requires bal- commercial kitchen ventilation sys- ance—air balance that is. And as the designer, installer or operator of the kitchen tems. The information presented is applicable to new construction and, in ventilation system, you may be the first person called upon to perform your own many instances, retrofit construction. “balancing act” when the exhaust hood doesn’t work. Unlike a cooking appliance, The audience for this guideline is which can be isolated for troubleshooting, the exhaust hood is only one component kitchen designers, mechanical engi- of the kitchen ventilation system. To further complicate things, the CKV system is a neers, food service operators, prop- subsystem of the overall building heating, ventilating and air-conditioning (HVAC) erty managers, and maintenance people. This guide is intended to system. Fortunately, there is no “magic” to the relationship between an exhaust hood augment comprehensive design in- and its requirement for replacement or makeup air (MUA). The physics are simple: formation published in the Kitchen air that exits the building (through exhaust hoods and fans) must be replaced with Ventilation Chapter in the ASHRAE outside air that enters the building (intentionally or otherwise). The essence of air Handbook on HVAC Applications. -
Table No. 1-A Uniform Mechanical Code
1997 EDITION TABLE NO. 1-A UNIFORM MECHANICAL CODE * This is a “fixed fee” based permit schedule. * Permit Issuance and Heaters 1. For the issuance of each mechanical permit………………………………….. $23.50 2. For issuing each supplemental permit for which the original permit has not expired, been canceled or finaled……………………………………………….. 7.25 Unit Fee Schedule (Note: The following do not include permit-issuing fee.) 1. Furnaces For the installation or relocation of each forced-air or gravity-type furnace or burner, including ducts and vents attached to such appliance, up to and including 100,000Btu/h(29.3W)…………………………………………………………… 14.80 For the installation or relocation of each forced-air or gravity-type furnace or burner, including ducts and vents attached to such appliance over 100,000 Btu/h(29.3kW).………………………………………………………………….. 18.20 For the installation or relocation of each floor furnace, including vent……………………………………………………….....................………… 14.80 For the installation or relocation of each suspended heater, recessed wall heater or floor-mounted unit heater………………………………………….…………. 14.80 2. Appliance Vents For the installation, relocation or replacement of each appliance vent installed and not included in an appliance permit..…..……...…...................................…… 7.25 3. Repairs or Additions For the repair of, alteration of, or addition to each heating appliance, refrigeration unit, cooling unit, absorption unit, or each heating, cooling, absorption or evaporative cooling system, including installation of controls regulated by the Mechanical Code……………………………………………….. 13.70 4. Boilers, Compressors and Absorption Systems For the installation or relocation of each boiler or compressor to and including 3 horsepower (10.6kW), or each absorption system to and including 100,000 B~ (29.3kW)……..……………….....................……………………………………. -
Introduction to Ventilation & Indoor Air Quality
INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY PRESENTED BY: Eng. Shehab S. Bekhet INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY How much time - %, do we spend indoors?? 2 INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY We Spend 90% of Our Time Indoors! ! 3 INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY 4 INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY Shehab Bekhet Senior Mechanical Engineer Dar Al Handasah More than 27 years of various experience, gained throughout long career path covers wide and diversified fields and ranges of responsibilities combining design, construction and technical back-up skills. The range of mechanical works cover preliminary & detailed design, preparation of specification and tender documents, follow up, approval of shop drawings and project management and construction supervision of building services including HVAC, plumbing, fire protection, building automation and control systems. Successfully contributed to design and construction of several large projects in more than 12 countries in the Gulf Area, Middle East, and Africa, such as: • Dubai International Airport- UAE • Higher College for Men & Women- UAE • Development of King Abdul Aziz Endowment for the Two Holy Mosques. • Al Hassa & Al Dammam Hospital – Saudi Arabia • Rafik Al Hariri Airport – Lebanon • Sheraton Hotel Rehabilitation – Egypt. A keynote speaker and administered many of training courses and seminars in various topics of HVAC systems. INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY 6 INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY Introductory Film Indoor Ar Quality INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY 8 INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY The presentation covers the following main items: Indoor Air Quality, (IAQ): . Definition. Common Pollutants and health effect. -
2018 Uniform Mechanical Code Preface
SOUTHERN NEVADA AMENDMENTS TO THE 2018 UNIFORM MECHANICAL CODE PREFACE This document was developed by the Southern Nevada Building Officials' Uniform Mechanical Code (UMC) Committee and presents recommended amendments to the 2018 Uniform Mechanical Code as published by the International Association of Plumbing and Mechanical Officials (IAPM0). Participation in the 2018 UMC Committee was open to all interested parties. However, voting on amendment proposals was limited to one vote each for six of Southern Nevada municipalities (Clark County, Henderson, Las Vegas, North Las Vegas, Boulder City, and Mesquite), the Clark County School District, and three industry representatives. All committee proceedings were conducted in accordance with Robert's Rules of Order. The recommended amendments contained herein are not code unless adopted and codified by governmental jurisdictions. These amendments are not intended to prevent the use of any material or method of construction not specifically prescribed herein, provided any alternates have been approved and their use authorized by the Building Official. This document may be copied and used in whole or in part without permission or approval from the organizations listed on the cover page. Page 2 of 8 Dated: July 3, 2018 Table of Contents Chapter1: Administration 4 Section 203 Definitions Section 304.3.1.2 Permanent Ladders Section 304.4 Appliances in Attics and Under-Floor Spaces Section 504.4 Clothes Dryers 5 Section 504.4.2.1 — Length Limitation Section 510.1.6.1 Bracing and Supports Section 511.2.2.1.1 Performance Test Section 603.4.1 Length Limitation 6 Section 603.13 Air Dispersion Systems Section 608.1 Automatic Shutoffs Section 802.6.1 Termination Requirements Section Chapter 10, Boilers and Pressure Vessels 7 Section 1301.2 Dry Gas Section 1310.1.6 Piping Underground Beneath Buildings Section 1701.1 Standards 8 Page 3 of 8 Dated: July 3, 2018 Section Chapter 1: Administration Delete Chapter 1 in its entirety, except for sections 101.1, 101.2 and 101.3. -
Key Factors and Problems in the Performance of Kitchen Ventilation Systems Explorative Review Study
FACULTY OF ENGINEERING AND SUSTAINABLE DEVELOPMENT Department of Building Engineering, Energy Systems and Sustainability Science Key factors and problems in the performance of kitchen ventilation systems Explorative review study Álvaro Ros Hueda 2020 Student thesis, Advanced level (Master degree, one year), 15 HE Energy Systems Master Programme in Energy Systems Supervisor: Alan Kabanshi Assistant supervisor: Roland Forsberg Examiner: Magnus Mattsson ABSTRACT Regarding the great importance of a good working environment, in this research, ventilation systems installed in kitchens of restaurants were studied in order to avoid problems and to understand the key factors that can influence on the performance of the system. The results obtained were taken into account to provide some recommendations to a real ventilation system of a restaurant called Pastaria in Gävle (Sweden). This concrete ventilation system was not performing good, and some calculations based on the kitchen design were made trying to offset the problem. A large number of scientific studies related to restaurant kitchen hoods and ventilation systems were used to get the findings. These articles were obtained from scholar web databases. The main problem found in kitchen hoods is the inadequate exhaust airflow. The minimum required airflow varies depending on the size and shape of the hood. Keil et al. (2004) found in their research that only 39% and 24% of the studied hoods met the minimum recommended airflow from ACGIH and ASHRAE guidelines, respectively. Other key factors found are related to the kitchen design. The kitchen hood is recommended to have incorporated a capture hood covering all the burners. Side panels can be employed to increase the capture and containment. -
Section 230001
DCAMM STANDARD SPECIFICATIONS MASS. STATE PROJECT NUMBER REV 7.1 - CMR PROJECT NAME, LOCATION SECTION 230001 HEATING, VENTILATING AND AIR CONDITIONING (Trade Bid Required) Trade Contractors on this CM at Risk project are required by law to provide Payment and Performance Bonds for the full value of their Trade Contracts, and Trade Contractors must include the full cost of the required Payment and Performance Bonds in the Bid price they submit in response to this RFB. Bids will only be accepted from Trade Contractors pre-qualified by the Awarding Authority. TABLE OF CONTENTS PART 1 - GENERAL ....................................................................................................................................5 1.1 GENERAL PROVISIONS ............................................................................................................5 1.2 DESCRIPTION OF WORK ..........................................................................................................6 1.3 SUBMITTALS ..............................................................................................................................8 1.4 DEFINITIONS.............................................................................................................................10 1.5 CONTRACT DOCUMENTS ......................................................................................................10 1.6 DISCREPANCIES IN DOCUMENTS .......................................................................................11 1.7 MODIFICATIONS IN LAYOUT ...............................................................................................11 -
Integrating Kitchen Exhaust Systems with Building HVAC – 07.22.09 2 Ventilation
Design Guide 3 Improving Commercial Kitchen Ventilation System Performance Integrating Kitchen Exhaust Systems with Building HVAC The Opportunity: Reduce Utility Costs and Improve This design guide provides information that may help achieve optimum perfor- Kitchen Comfort mance and energy efficiency in com- mercial kitchen ventilation systems by The replacement air required for commercial kitchen ventilation systems integrating kitchen exhaust with building HVAC. The information presented is is always 100% of the exhaust air—what goes out must come in! A common applicable to new construction and, in some instances, retrofit construction. design practice is to supply at least 80% of replacement air using an independent The audience for this guideline is kitch- en designers, mechanical engineers, makeup air unit (MAU) with the remaining 20% supplied by conditioned outside code officials, food service operators, air from heating, ventilating, and air-conditioning (HVAC) roof-top units (RTU) property managers, and maintenance people. The building code analysis is serving the kitchen and/or by transfer air from adjacent spaces. This keeps the focused on California’s Title 24. This guide is intended to augment compre- kitchen under a negative pressure (relative to the dining room) to prevent cook- hensive design information published in the Kitchen Ventilation Chapter in the ing odors from migrating into the dining area. In many climates the replacement ASHRAE Handbook on HVAC Applica- tions, as well as companion publications air from an independent makeup air unit is not conditioned, which may create under the design series subtitled Im- uncomfortable conditions (too cold and/or too hot) in the kitchen.