Surge Protection & Line Conditioning Catalog

Total Page:16

File Type:pdf, Size:1020Kb

Surge Protection & Line Conditioning Catalog A Network Approach to Surge Protection and Line Conditioning UL Revised September, 1999 14 49 nd 2 EDITION LISTED PRODUCTS Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Leviton offers advanced surge suppression technology with network application strategies, to give you unmatched protection. The quality and variety of Leviton surge protection devices (SPD’s) allows you to optimize network protection by distributing it throughout a facility. Panel-mounted devices are installed at the service entrance to immediately reduce external surges. To prevent equipment damage from both internal and external surges, we offer branch panel and point-of-use devices to fit all environments and applications. Leviton provides a single source for the SPD’s you need to connect and protect! Leviton point-of-use devices come in a variety of styles so you can choose what’s right for your application, from hard-wired receptacles to plug-ins, plug-strips and a specialized power control center for integrated computer work stations. They also come in different grades to suit the needs of industrial, commercial and residential environments. Leviton’s wide selection of SPD’s provide various levels of protection, so you can choose the one that’s appropriate for your equipment. At Leviton, we are proud to state that we have been developing electrical and electronic wiring devices for over 90 years. During that time, we have been active in establishing industry-wide standards and educating the marketplace. Our nationwide team of over 200 factory-employed salespeople and industrial specialists has further established Leviton as a leading manufacturer of power quality devices. We look forward to continuing our efforts in developing not only innovative products but also in supporting our customers with effective power quality solutions. Products in this catalog are sorted by application: Each symbol below represents a specific application. Please refer to the Table of Contents at right to locate the products in this brochure that meet the exact needs of your particular application. Plug-In Line and Ground Low-Voltage Panel-Mounted Hard-Wired Conditioning and Data line Devices Devices Devices Devices Devices ©1999 (September) Leviton Manufacturing Co., Inc. All rights reserved. Note: All information contained herein was accurate at time of publication. Because Leviton engages in a continuing program of product improvement, all data is subject to change without notice. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 !2 Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Table of Contents Leviton’s network protection approach 5 An objective measure — IEEE C62 Standards 6 Testing to IEEE C62 Standard 7 UL verification of clamping data: Standard 1449 7 The NEMA LS-1 Specification Format 8 Application Environments (Including the Rockwell Automation Allen-Bradley ENCOMPASS Program) 9 Leviton Support Services 9 Product Section 11 Cat. No. 57000 Panel-Mounted Devices 12 Cat. No. 52000 Panel-Mounted Devices 14 Cat. No. 52000-RS Remote Supervisor 14 Cat. No. 47000 Panel-Mounted Devices 17 Cat. No. 32000 Panel-Mounted Devices 19 Cat. No. 42000 Panel-Mounted Devices 19 Cat. No. 51120 Panel-Mounted Devices 22 Cat. No. 50240-MSA Meter Socket Surge Arrester Adapter 24 Cat. No. 51020 and 51240 Wired-Module Devices 26 Cat. No. 3800 Equipment Cabinet Devices 28 Cat. No. 3803-DPH and 3803-485 Communication Protection Modules 30 Surge Suppression Single and Duplex Receptacles 33 Four-In-One Surge Suppression Receptacles 35 Plug-In Devices 37 Plug-Strip Devices 40 Computer Grade, Commercial Grade and General Purpose Grade Devices 43 Cat. No. 5400 Power Control Center 45 Cat. No. 5500 Rack-Mounted Devices 46 Line and Ground Conditioning Devices 48 Stand-Alone Low-Voltage Communications/Data Line Devices 51 Terms of Leviton Product Warranty and Downline Lifetime Limited Warranty 54 Index 55 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 3! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 4. 2. 3. 1. Applications For Commercial /Light Industrial Facility Above is a simplified example of the varied equipment which should be protected by surge protective devices. The existence of mission-critical electronic equipment located throughout a facility leaves many organizations vulnerable to transient voltage surges. 1. Power Distribution 3. Building Controls 4. Computers & Communications I Load center I Building management systems I Voice/data equipment I Switchgear I Motor controls (PBX system, LAN’s, WAN’s) I Distribution equipment I Drives I Security system I Fire alarm system I Patch Panels 2. Electrical Loads I UPS systems I Lamps I Ballasts I Lighting controls Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 !4 Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Leviton’s Advanced Surge Suppression Technology Combined With Network Application Strategies Sets The Standard For Unmatched Protection Leviton’s Network Approach throughout a facility’s AC distribution From service entrance to point of use, system. Leviton’s complete Surge Protective With a protection network installed Devices product line offers a spectrum along these lines, Figure 1 shows the of products, to cover virtually every surge-suppression sequence when a requirement in both new construction high-energy transient strikes from an and retrofit installations. outside source. The step-by-step The outstanding versatility of Leviton’s zoned protection begins at the service product line permits the application entrance, and extends to the point of a powerful network strategy that of use. provides effective surge suppression Figure 1 Incoming Lightning Surge 6 KV. 3KA. Service Distribution Entrance Panel Mount SPD SPD Point-of-Use SPD Leviton Leviton Leviton 5300P 57000 52000 2500A 400A 80A LOAD Service Entrance Ground Rod Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-63705 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com An Objective Measure Of Figure 2 Surge Protective Device Performance — ABC The IEEE C62 Standards Collection When describing performance Service Entrance of Surge Protective Devices, Meter many factors play a part in determining the effectiveness of these products. This can make it difficult to carry out a reasonable comparison between performance charac- teristics of competing products. Therefore, the Institute of Electrical and Electronic Engineers, or IEEE, established uniform requirements that Service characterize the environments Entrance for evaluating the performance Outbuilding of Surge Protective Devices. Meter Standard C62.41 describes three general categories of operating environment for Underground Service Surge Protective Devices. As shown in Figure 2, the three system exposure environments are called Category A, Category B, and Category C. With operating environment categories well defined, the IEEE also established a very Service Entrance Outbuilding precise description of several transient voltage and current Transformer waveforms that would be expected within each of these areas. The transient waveforms are configured as ringwaves Underground and combination waves. Service Charts 1 and 2 show the exact parameters that describe these waveforms in Category A, B A B C and C operating environments. • Outlets & long • Feeders and short branch circuits • Outside and service entrance Note that for Categories A branch circuits • Distribution panel devices • Service drop from and B, there are low, medium • All outlets at more • Bus and feeder industrial plants pole to building and high-exposure ringwave than 10m (30ft.) • Heavy appliance outlets with “short” • Run between transients shown in Chart 1. from Category B connections to service entrance meter & panel In Chart 2, there are low, • Overhead line to • All outlets at more • Lighting systems in large buildings detached building medium and high-exposure than 20m (60ft.) combination-wave transient • Underground from Category C line to well levels for Categories B and C. pump Demarcation between Location Categories B and C is arbitrarily taken to be at the meter or at the mains disconnect (ANSI/NFPA 70-1990 {2}, Article 230-70) for low-voltage service, or at the secondary of service transformer if the service is provided to the user at a higher voltage. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 !6 Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Testing to IEEE Chart 1 Standard 0.5 µs-100 kHz Ring Wave C62.41 Standards Voltages and Current Surges Expected in Location Categories A and B Low, Medium and High Exposures Single-Phase Modes: L-N, L-G, and [L&N]-G Confirms Surge Polyphase Modes: L-L, L-G, and [L’s]-G Protective Device Peak Values Effective Location System Voltage Current Impedance Category Exposure Ω Performance (kV) (kA) ( ) Using the IEEE Standard wave- A1 Low 2 0.07 30 forms, all manufacturers of Surge A2 Medium 4 0.13 30 Protective Devices now have a A3 High 6 0.2 30 common basis for making compar- B1 Low 2 0.17 12 isons. When subjected to consis- B2 Medium 4 0.33 12 tent, well-defined
Recommended publications
  • The ABC's of Lightning
    DEHN, INC. The ABC’s of Lightning TO BE SURE, USE DEHN® Lightning represents a stunning combination of nature’s beauty and awesome power Lightning currents conducted in modern electrical circuits can cause immediate and catastrophic equipment failure. Surges from induced lightning and power switching operations are smaller but are more numerous and can result in equipment misoperation, lockup or damage. DEHN®’s mission is “to protect life and property from the hazards of lightning and surges.” Lightning cannot be prevented, but proper use of DEHN®’s Lightning and Surge protection can safely divert lightning currents away from ourselves, our homes and our businesses. DEHN® has been providing Surge and Lightning Protection around the world for over 90 years. Currently employing a staff of over 1000 highly qualified personnel throughout the world, DEHN® is active in over 50 countries. DEHN® invests heavily in research and development, and is active in contributing and exchanging information with others at international technical conferences. The information contained in this catalog is as complete and accurate as possible. However DEHN® Inc., reserves the right to make changes to product specification and data without advance notice or obligation. © COPYRIGHT 2002 DEHN®, Inc. The ABC’s of Lightning and Surges A surge is a very short burst of voltage, which if In addition, the Rocky, Appalachian, and Sierra not suppressed, can cause equipment failure or lockup. Nevada mountain ranges have low ratio of cloud to cloud vs The duration of a surge is less than 1/1000 of a second. cloud to ground which means that a higher percentage Measurements of actual lightning strikes have shown of strikes reach the ground.
    [Show full text]
  • Silicon Surge Protector
    CAT.No.U029-4 SILICON SURGE PROTECTOR SHINDENGEN ELECTRIC MFG. CO., LTD. SILICON SURGE PROTECTOR ■The products shown in this catalog are intended for use in standard applications requiring normal,commercial levels of reliability. lf these products are to be used in equipment or devices requiring special or specific levels of quality and reliability in which failure or malfunction of a product may directly affect human life or health,contact the local SHINDENGEN office to confirm that the intended use of the product is appropriate. The quality levels of our products are defined below: Standard Applications Computers, office automation, communication terminals, test and measurement instrumentation,AV equipment,video games and related amusement equipment,home appliances,machine tooIs,industrial robots, personal equipment,etc. Special AppIications Transportation( automotive, marine, etc.) trunk-line communication, traffic signal equipment,commercial fire prevention/anti-theft equipment, various safety devices,medical equipment,etc. Specific Applications Nuclear power controIs,aerospace and aeronautical equipment,submarine relay equipment,devices and systems for preserving life,etc. ■Although efforts are constantIy made to improve quality and reliability,please select a product after careful examination so that personal injury,accidents and social damage can be prevented as a result of deploying measures such as a redundant design,designs that prevent the spreading of fire,designs that prevent malfunctions and so forth while taking safety into consideration as necessary. One of the most important issues regarding the construction of a high-level information system is to protect the electronic equipment and systems against various disasters. SHINDENGEN is proud to introduce our line of high-performance Silicon Surge Protectors,which are suited to a wide variety of digitaI applications.
    [Show full text]
  • Motor Surge Protection Type MSP
    Motor Surge Protection ̈̈̈̈̈ Type MSP ̈ 2.4 to 24 kV ̈ Surge protection for critical industrial loads: • Large motors and generators Specialty Capacitors • Large transformers • Medium-voltage switchgear and motor control centers Electrical distribution systems are subject to power surges, switching transients, faults, and lightning strikes at anytime. Such occurrences can be damaging to electrical systems, as well as various apparatus used in a manufacturing process. ABB offers the Type MSP,a protective device that provides protection for motors, rotating machines, and transformers, and yields assurance of continuous operation of the equipment, the electrical system, and the manufacturing process. The primary function of the Type MSP motor surge protector is to guard the winding insulation of the device being protected. Station class, metal oxide lightning arresters act to limit the maxi- mum voltage to the device to a predetermined magnitude. Specially designed surge capacitors, connected in parallel with the arresters, control the rate of rise of the resultant overvoltage. The combination of surge arresters and surge capacitors serve to limit the turn-to-turn insulation stress impressed on the device being protected. STANDARD FEATURES ̈ Rugged-welded 11-gauge metal enclosure ̈ Indoor NEMA 1/12" enclosure ̈ ANSI #61 light gray paint ̈ Heavy-duty rated surge capacitors ̈ Station class MOV surge arresters ̈ Copper bus bars ̈ Common ground connections OPTIONAL ̈ Hinged, padlockable front door ̈ Outdoor NEMA 3R enclosure ̈ Removable cable entry plates for top ̈ NEMA 4X stainless steel enclosure or bottom feed ̈ Intermediate class MOV surge arresters All ABB products are IndustrialIT enabled.
    [Show full text]
  • Varistors: Ideal Solution to Surge Protection
    Varistors: Ideal Solution to Surge Protection By Bruno van Beneden, Vishay BCcomponents, Malvern, Pa. If you’re looking for a surge protection device that delivers high levels of performance while address- ing pressures to reduce product size and compo- nent count, then voltage dependent resistor or varistor technologies might be the ideal solution. ew regulations concerning surge protection limit the voltage to a defined level. The crowbar group in- are forcing engineers to look for solutions cludes devices triggered by the breakdown of a gas or in- that allow such protection to be incorpo- sulating layer, such as air gap protectors, carbon block de- rated at minimal cost penalty, particularly tectors, gas discharge tubes (GDTs), or break over diodes in cost-sensitive consumer products. In the (BODs), or by the turn-on of a thyristor; these include automotiveN sector, surge protection is also a growing ne- overvoltage triggered SCRs and surgectors. cessity—thanks to the rapid growth of electronic content One advantage of the crowbar-type device is that its very in even the most basic production cars combined with the low impedance allows a high current to pass without dissi- acknowledged problems of relatively unstable supply volt- pating a considerable amount of energy within the protec- age and interference from the vehicle’s ignition system. tor. On the other hand, there’s a finite volt-time response Another growing market for surge protection is in the as the device switches or transitions to its breakdown mode, telecom sector, where continuously increasing intelligence during which the load may be exposed to damaging over- in exchanges and throughout the networks leads to greater voltage.
    [Show full text]
  • ISOLATOR/SURGE PROTECTOR 118Ka BACKGROUND
    LITERATURE ISOLATOR/SURGE PROTECTOR 118kA BACKGROUND This addendum to “The Isolator/Surge Protector” describes the operation of the ISP in greater detail. It is assumed that the reader has already read the ISP Introduction for a general discussion of the features and characteristics. To reiterate some of the ISP introduction material, the ISP blocks the flow of DC current and readily conducts AC current as long as the absolute value of the voltage across its terminals is less than a preselected voltage threshold level (12.5 or 20 volts) and the steady-state AC current is also within its rating. If either of these conditions are exceeded, the ISP momentarily transitions from its “blocking DC/conducting AC” mode to a virtual short circuit to both AC and DC. This transition is accomplished within 1 to 4 microseconds by the logic-controlled circuit turning ON thyristor T1 or T2 (depending on polarity). This protects the DC blocking/AC by-pass capacitor from failure due to excessive current. It also provides over-voltage protection between the two points to which the ISP is connected. Reference Figure 1 for a simplified diagram of the ISP showing all key circuit elements. Figure 1: Isolator/Surge Protector Circuit Figure 2: Simplified Isolator/Surge Protector DURING DC CONDITIONS Whenever the DC voltage exceeds the voltage transition level selected, cathodic isolation is then interrupted until the transient The ISP appears as an open circuit to any DC voltage up to condition which caused the ISP to transition to its shorted mode the 12.5 or 20 volt peak transition level selected.
    [Show full text]
  • TECH TIP – What Is Varistor?
    TECH TIP – What is Varistor? A varistor is a voltage dependent resistor (VDR). The resistance of a varistor is variable and depends on the voltage applied. The word is composed of parts of the words “variable resistor”. Their resistance decreases when the voltage increases. In case of excessive voltage increases, their resistance drops dramatically. This behavior makes them suitable to protect circuits during voltage surges. Causes of a surge can include lightning strikes and electrostatic discharges. The most common type of VDR is the metal oxide varistor or MOV. A varistor typically comes in a disc package: Characteristics A voltage dependent resistor has a nonlinear varying resistance, dependent on the voltage applied. The impedance is high under nominal load conditions, but will sharply decrease to a low value when a voltage threshold, the breakdown voltage, is exceeded. They are often used to protect circuits against excessive transient voltages. When the circuit is exposed to a high voltage transient, the varistor starts to conduct and clamps the transient voltage to a safe level. The energy of the incoming surge is partially conducted and partially absorbed, protecting the circuit. The most important selection parameter is the clamping voltage. It is recommended to use as high clamping-voltage as the protected circuit allows, to limit the amount of exposure to surges. For example, to protect 120VAC circuits, you would use an MOV rated at 150V as long as the circuit would allow voltages up to 150V. Varistors are useful for short duration protection in case of high transient voltage surges in the order of 1-1000 microseconds.
    [Show full text]
  • Stock Products Catalog
    2016 Stock Products Catalog EFFECTIVE January 1, 2016 PRIME WIRE & CABLE, Inc. 280 Machlin Court, City of Industry, CA 91789-3026 Industrial Products Division: Toll Free: (800) 962-2738 Fax: (800) 797-2226 Retail Products Division: Toll Free: (888) 445-9955 Fax: (909) 859-2926 www.primewirecable.com Table of Contents OUTDOOR EXTENSION CORD S ................................................................................................................. 4-7 Bulldog Tough ® Cords, Generator Cords & Adapters, TPE-Rubber Arctic Blue ™ All Weather Cords, Glacier Flex ® Cold Weather Cords, High Visibility Neon Flex ® Cords, Kaleidoscope of Colors ® Cords, Primelok ® Locking Connector Cords, No-Overload ® Circuit Breaker Cords, Farm & Shop Cords, Rubber Cords, Landscape Cords, Outdoor Cords, Outdoor Triple Tap Cords, Outdoor Twist-to-Lock Cords SHOCK-SAFE ® G.F.C.I. PRODUCT S................................................................................................................7 WIRING DEVICE S ........................................................................................................................................7 APPLIANCE & POWER SUPPLY CORD S..........................................................................................................8 Range & Dryer Cords, Air Conditioner Cords, Power Supply Cords HOUSEHOLD & UTILITY CORD S.................................................................................................................8-9 Household Cords, Snug Plug ® Cords, Office Cords, Shop and Utility
    [Show full text]
  • 3 Keys to Choosing a Surge Protector
    3 KEYS TO CHOOSING A SURGE PROTECTOR There are many different kinds of surge protectors. Surge protectors installed on power lines don’t absorb or otherwise diminish damaging power surges. Their primary function is to divert these destructive forces away from your sensitive circuitry. There are four basic kinds of surge protectors: metal oxide varistors (MOVs), avalanche diodes, filters, and gas tubes. Metal oxide varistors (MOVs) are a common choice. The word varistor is a combination of two words: variable resistor. As these words imply, an MOV is a highly resistive device that triggers during an AC power surge and diverts the excess voltage, preventing it from reaching your expensive computer equipment. MOVs are designed to accommodate surge levels up to a specified breakdown voltage. When this limit is exceeded, the MOV varies from a highly resistive state to a state of low resistance. The excess energy is “clipped” from the power line and sent to ground. Surges occurring at the peak of a sine wave are clipped by the MOV, but high-voltage spikes may still occur (though they’ll eventually be clipped), and the MOV response times can range up to 500 picoseconds. This is the primary weakness of an MOV, but it’s usually overcome by the inclusion of some other suppression technique within the surge protector. Avalanche diodes, also known as Zener diodes, are semiconductor devices similar to MOVs, but they feature much faster response times (usually less than one picosecond). Avalanche diodes are available in a wider range of sizes to provide accurate and repeatable voltage clamping.
    [Show full text]
  • MSP™ - Medium Voltage Motor Surge Protection
    66 Carey Road | Queensbury, NY | 12804 Ph: (518) 792-4776 | Fax: (518) 792-5767 www.nepsi.com | [email protected] MSP™ - Medium Voltage Motor Surge Protection General NEPSI's MSP™ (Motor Surge Protector) is de- signed to protect medium voltage motors and gen- erators from voltage surges due to lightning and switching events. The MSP™ accomplishes this task better than any other product by decreasing the slope and crest of impending voltage surges to safe levels. Application of the MSP™ is guaranteed to reduce the likelihood of motor failures, resulting in less down-time and higher productivity. Figure 1 NEPSI's Medium Voltage Motor Surge Protection equip- ment protects motor insulation from power system transi- ents. Product Scope Reduced medium voltage motor and generator failures from voltage surges due to lightning, faults, and switching events. Units can be custom designed for direct mounting to generators, mo- tor, and compressor housing. Units can be supplied with over- current and differential protection current transformers. Reduced downtime and material waste from motor failure. Simple to install and requires no maintenance. MSP's are custom designed for many OEM’s utilizing medium volt- age motors and generators. Figure 2 Principle operation of the MSP™ is to decrease the crest voltage and rate of rise of the impending surges. High rates of rise damage end turns while high crest voltages damage winding to core insulation. Both of these types of damaging surges are mitigated with NEPSI's MSP™. P a g e | 1 Bulletin: 700-00 Rev. Date: 9/25/2015 Northeast Power Systems, Inc.
    [Show full text]
  • 5 Causes of Power Surges and How to Protect Your Property
    5 Causes of Power Surges and How to Protect Your Property Power surges happen whenever the wiring in your home or office experiences brief jolts of high electrical voltage. Power surges can be minor or severe. Even appliances or electronics that are turned off can flicker or buzz during a power surge, making it seem as though Casper is paying you a visit. Far from harmless though, power surges can damage your electrical outlets, fry your appliances and electronics and start dangerous electrical fires. Being cognizant and proactive against the causes of power surges can potentially save your electronics and more importantly, your life. Here are five serious causes of power surges and what you can do to protect your home or business. 1. Overloaded Outlets or Circuits Survey the outlets under your desk, behind your television set, or anywhere else you have a tangled web of wires. Plugging in too many appliances or electronics in the same socket can lead to power surges and electrical fires. If you are experiencing power surges, have an electrician check to see if all of the outlets in a room might be operating on the same circuit. If so, overloading one outlet might not be the problem. The circuit itself may be overloaded trying to power too many appliances in the same room. 2. Damaged or Exposed Wiring Pesky little critters such as mice or squirrels can chew on the wiring inside the walls of your house or building causing the wiring to fail. Damaged or exposed wires can cause power surges because the electricity flowing through them is not being directed or handled in the way it normally should.
    [Show full text]
  • Open Forum on Surge Protection Application Editor: Frariqois D
    Open Forum on Surge Protection Application Editor: FrariQois D. Martzloff U.S. DEPARTMENT OF COMMERCE National Institute of Standards and Technology Bectronics and Bectrical Engineering Laboratory Bectrldty Division Gaithersburg, MD 20899 Co-sponsored by: Computer Business Equipment Manufacturers Association Bectric Power Research Institute IEEE Standards Coordinating Committee 22 on Power Quality IEEE Surge-Protective Devices Committee ILS. DEPARTMENT OF COMMERCE Robert A. Mcebacher, Smcntmy NATIONAL msrnUTl OF STANDARDS AND ISCHNOLOOY JolH ¥L LyoM, dC— Diraetor 100 .U56 NIST /M657 1991 NISTIR 4657 Proceedings Open Forum on Surge Protection Appiication Editor: Francois D. Martzloff U.S. DEPARTMENT OF COMMERCE National Institute of Standards and Technology Electronics and Electrical Engineering Laboratory Electricity Division Gaithersburg, MD 20899 Co-sponsored by: Computer Business Equipment Manufacturers Association Electric Power Research Institute IEEE Standards Coordinating Committee 22 on Power Quality IEEE Surge-Protective Devices Committee August 1991 US. DEPARTMENT OF COMMERCE Robert A. Mosbacher, Secretary NATIONAL INSrnun OF STANDARDS AND TECHNOLOGY Jotai W. Lyoee, Diractor ii Table of Contents FOREWORD V THE SURGE ENVIRONMENT Power Quality Comparison - 1979 vs. 1991 1 Douglas S. Dorr, National Power Laboratory Voltage Surge Generated by Static Converters 11 Suang Khuwatsamrit, Reliance Electric Company On the Propagation of Old and New Surges 19 Francois D. Martzloff, National Institute of Standards and Technology THE PERFORMANCE OF SURGE-PROTECTIVE DEVICES Transient Voltage Surge Suppressor Specifications: Realistic Performance or Smoke and l^rrors? 27 O. Melville Clark, General Semiconductors Industries, Inc. Time Response of TVSS Devices 33 Hans j. Steinhoff, Joslyn Performance of MOV Suppressors in Low-Voltage AC Circuits 43 Martin P. Corbett, Harris Semiconductor and Bernhard I.
    [Show full text]
  • Surge Protective Devices (SPD) SPEEDFAXTM Section
    Surge Protective Devices (SPD) SPEEDFAXTM Section c o n t e n t s Siemens Residential and Commercial Surge Protective Devices Scan to connect online to the most up-to- Family SPDs 10-2 date version of SOLID Protection 10-3 this Section of SPEEDFAX. BoltShield™ Surge Protective Devices 10-4 – 10-5 First Surge 10-6 – 10-7 TPS3 01 and TPS3 L1 (10 Mode) 10-8 TPS4 01 and TPS4 L1 (10 Mode) 10-9 TPS3 02 and TPS3 L2 (10 Mode) 10-10 TPS3 03 10-11 TPS3 03 DC 10-12 TPS3 05 and TPS3 L5 (10 Mode) 10-13 TPS4 05 and TPS4 L5 (10 Mode) 10-14 TPS3 06 and TPS3 L6 (10 Mode) 10-15 TPS4 06 and TPS4 L6 (10 Mode) 10-16 TPS3 09 10-17 TPS3 11 10-18 TPS3 12 and TPS3 L12 (10 mode) 10-19 TPS3 15 and TPS3 L15 (10 mode) 10-20 Frequently Asked Questions 10-21 Internally Mounted SPDs External or Wall Mounted SPDs Residential SPDs See pages 10-9 – 1-52 Features Features Features n Per Phase Surge Current Capacity n Per Phase Surge Current Capacity n Per Phase Surge Current Capacity ranging from 100 kA to 500 kA ranging from 50 kA to 1000 kA of 40, 50, 60, 100 or 140 kA n n n Industry best VPRs Industry best VPRs Complete Service Protection for 10 n In = 20 kA (most models) n In = 20 kA (most models) - Power n Across the board UL 96A compliance n Across the board UL 96A compliance - Telephone (most models) (most models) - Coax SPD n n Ground Reference Monitoring Ground Reference Monitoring n Ground Reference Monitoring (GRM) diagnostics (GRM) diagnostics (GRM) diagnostics (excluding TPS3 03 & TPS3 09) (Section was last modified on 08/13/21) Siemens Industry, Inc.
    [Show full text]