Dell EMC Host Connectivity Guide for Windows

Total Page:16

File Type:pdf, Size:1020Kb

Load more

Dell EMC Host Connectivity Guide for Windows P/N 300-000-603 REV 59 This document is not intended for audiences in China, Hong Kong, and Taiwan. Copyright © 2015 - 2017 Dell Inc. or its subsidiaries. All rights reserved. Published May 2017 Dell believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. Dell, EMC2, EMC, and the EMC logo are registered trademarks or trademarks of Dell Inc. or its subsidiaries. All other trademarks used herein are the property of their respective owners.. For the most up-to-date regulator document for your product line, go to Dell EMC Online Support (https://support.emc.com). 2 Dell EMC Host Connectivity Guide for Windows CONTENTS Preface........................................................................................................................................ 9 Chapter 1 General Procedures and Information General Windows information.................................................................... 14 Terminology........................................................................................ 14 Utilities and functions ......................................................................... 14 Windows environment............................................................................... 15 Hardware connectivity........................................................................ 15 Booting Windows from external storage.................................................... 16 Boot-from-SAN .................................................................................. 16 Benefits of boot-from-SAN ................................................................ 16 Boot-from-SAN configuration restrictions.......................................... 16 Risks of booting from the storage array.............................................. 17 How to determine I/O latency and load on the boot LUN ................... 17 Configuring Unity and VNX series systems for boot from SAN........... 18 SAN Booting a Windows Host to a Unity array .......................................... 19 Prerequisites ...................................................................................... 19 Configure host connections................................................................ 19 Create a LUN and configure to the host .................................................... 23 Microsoft Windows Failover Clustering ..................................................... 28 Chapter 2 iSCSI Attach Environments Introduction.............................................................................................. 30 Terminology....................................................................................... 30 Software............................................................................................ 30 Boot device support .......................................................................... 30 Windows 2008 R2 iSCSI Initiator manual procedure.................................. 31 Windows 2008 R2 iSCSI Initiator cleanup.......................................... 35 Using MS iSNS server software with iSCSI configurations........................ 38 iSCSI Boot with the Intel PRO/1000 family of adapters............................. 39 Preparing your storage array for boot................................................. 39 Post installation information ............................................................... 41 Notes on Microsoft iSCSI Initiator............................................................. 44 iSCSI failover behavior with the Microsoft iSCSI initiator................... 44 Microsoft Cluster Server ................................................................... 60 Boot................................................................................................... 60 NIC teaming........................................................................................ 61 Using the Initiator with PowerPath..................................................... 61 Commonly seen issues....................................................................... 65 Chapter 3 Virtual Provisioning Virtual Provisioning on Symmetrix............................................................. 70 Terminology........................................................................................ 71 Management tools .............................................................................. 72 Thin device ......................................................................................... 72 Implementation considerations.................................................................. 74 Over-subscribed thin pools................................................................. 74 Dell EMC Host Connectivity Guide for Windows 3 Contents Thin-hostile environments .................................................................. 75 Pre-provisioning with thin devices in a thin hostile environment......... 75 Host boot/root/swap/dump devices positioned on Symmetrix VP (tdev) devices ............................................................. 76 Cluster configurations ........................................................................ 76 Operating system characteristics .............................................................. 78 Chapter 4 Windows Host Connectivity with Dell EMC VPLEX Dell EMC VPLEX ...................................................................................... 80 Prerequisites ............................................................................................. 81 Host connectivity...................................................................................... 82 Configuring Fibre Channel HBAs ............................................................... 83 Setting queue depth and execution throttle for QLogic ...................... 83 Setting queue depth and queue target for Emulex.............................. 88 Windows Failover Clustering with VPLEX.................................................. 91 Setting up quorum on a Windows 2012/2012 R2 Failover Cluster for VPLEX Metro or Geo clusters .............................................................. 92 Configuring quorum on Windows 2008/2008 R2 Failover Cluster for VPLEX Metro or Geo clusters ............................................................. 96 VPLEX Metro or Geo cluster configuration........................................ 96 Prerequisites ...................................................................................... 97 Setting up quorum on a Windows 2008/2008R2 Failover Cluster for VPLEX Metro or Geo clusters ....................................................... 97 Chapter 5 Dell EMC PowerPath for Windows PowerPath and PowerPath iSCSI............................................................ 104 PowerPath for Windows.......................................................................... 105 PowerPath and MSCS...................................................................... 105 Integrating PowerPath into an existing MSCS cluster ...................... 105 PowerPath verification and problem determination ................................. 108 Problem determination ...................................................................... 110 Making changes to your environment ................................................ 113 PowerPath messages ........................................................................ 113 Chapter 6 Microsoft Native MPIO and Hyper-V Native MPIO with Windows Server 2008/Windows Server 2008 R2........ 116 Support for Native MPIO in Windows Server 2008 and Windows Server 2008 R2 .................................................................. 116 Configuring Native MPIO for Windows 2008 Server Core and Windows 2008 R2 Server Core.......................................................... 116 Native MPIO with Windows Server 2012 ................................................. 120 Support for Native MPIO in Windows Server 2012 ........................... 120 Configuring Native MPIO for Windows Server 2012 ......................... 120 Known issues .......................................................................................... 125 Hyper-V................................................................................................... 126 Appendix A Persistent Binding Understanding persistent binding ........................................................... 128 Methods of persistent binding .......................................................... 130 4 Dell EMC Host Connectivity Guide for Windows Contents Appendix B Dell EMC Solutions Enabler Dell EMC Solutions Enabler .................................................................... 132 References ....................................................................................... 132 Appendix C Veritas Volume Management Software ......................................... 133 Dell EMC Host Connectivity Guide for Windows 5 Contents 6 Dell EMC Host Connectivity Guide for Windows FIGURES FIGURES 1 Four paths ...............................................................................................................
Recommended publications
  • How Broad All-Flash Vendor Portfolios Help IT Customers

    How Broad All-Flash Vendor Portfolios Help IT Customers

    White Paper How Broad All-Flash Vendor Portfolios Help IT Customers Sponsored by: Dell EMC Eric Burgener May 2017 IDC OPINION In the current 3rd Platform computing era, enterprises of all sizes are being asked to continue to support legacy applications while providing support for next-generation applications (NGAs) in mobile computing, social media, big data/analytics, and cloud environments. At the same time, most information technology (IT) organizations are consolidating around virtual infrastructure for both legacy and new applications. This has significantly changed the I/O profiles that storage infrastructure has to deal with, and it has become clear that for most primary storage workloads, and even now for some secondary workloads, hard disk drives (HDDs) no longer adequately meet requirements. As a result, we are seeing overall enterprise storage revenue shift away from HDD-based designs toward newer flash-based designs with the following results: . Flash is rapidly coming to dominate primary workloads as a persistent storage medium. For latency-sensitive workloads, flash offers performance, capacity, storage density, energy and floor space consumption, efficiency, and reliability benefits that are compellingly better than the benefits systems based around HDDs can offer for 3rd Platform computing workloads, and 76% of enterprises plan to deploy or evaluate all-flash array (AFA) platforms in the next 12 months. Differing workload requirements are driving the rise of new storage architectures. In the past, most enterprise storage designs were based around a scale-up, dual-controller model, but in the past several years, new architectures have emerged, which include scale-out, software- defined, converged and hyperconverged infrastructure, and cloud designs.
  • CLOUDIQ DETAILED REVIEW a Proactive Monitoring and Analytics Application for Dell EMC™ Storage Systems

    CLOUDIQ DETAILED REVIEW a Proactive Monitoring and Analytics Application for Dell EMC™ Storage Systems

    CLOUDIQ DETAILED REVIEW A Proactive Monitoring and Analytics Application for Dell EMC™ Storage Systems Efficiency Flash Health Scores Performance Notifications ABSTRACT This white paper introduces Dell EMC™ CloudIQ, a free, cloud-native application that lets you easily monitor, analyze, and troubleshoot your Dell EMC Unity, SC Series, XtremIO, and PowerMax/VMAX systems from anywhere and at any time. This paper provides a detailed description of how to use CloudIQ to proactively monitor and troubleshoot Dell EMC storage systems. January 2019 1 The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any software described in this publication requires an applicable software license. Copyright © 2018 Dell Inc. or its subsidiaries. All Rights Reserved. Dell EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners. Published in the USA [1/2019] [White Paper] [H15691.4] Dell EMC believes the information in this document is accurate as of its publication date. The information is subject to change without notice. TABLE OF CONTENTS EXECUTIVE SUMMARY ...........................................................................................................5 Audience ..........................................................................................................................................
  • Using EMC VNX Storage with Vmware Vsphere Techbook CONTENTS

    Using EMC VNX Storage with Vmware Vsphere Techbook CONTENTS

    Using EMC® VNX® Storage with VMware vSphere Version 4.0 TechBook P/N H8229 REV 05 Copyright © 2015 EMC Corporation. All rights reserved. Published in the USA. Published January 2015 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC2, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries. All other trademarks used herein are the property of their respective owners. For the most up-to-date regulatory document for your product line, go to EMC Online Support (https://support.emc.com). 2 Using EMC VNX Storage with VMware vSphere TechBook CONTENTS Preface Chapter 1 Configuring VMware vSphere on VNX Storage Technology overview................................................................................... 18 EMC VNX family..................................................................................... 18 FLASH 1st.............................................................................................. 18 MCx multicore optimization..................................................................
  • Dell Emc Unity Hybrid Storage

    Dell Emc Unity Hybrid Storage

    SPECIFICATION SHEET DELL EMC UNITY HYBRID STORAGE The ultimate in simplicity & unifieD flash value The Dell EMC Unity™ HybriD-Flash proDuct line sets new stanDarDs for storage with compelling simplicity, moDern design, flexible deployments and affordable prices– to meet the neeDs of resource-constraineD IT professionals in large or small companies. If you are looking for rich features anD absolute simplicity in a small footprint, if you are cost-conscious anD need the best from the best, Dell EMC Unity HybriD Flash is for you. DesigneD for flash with rich Data services, it delivers flash performance with the cost advantage of disk. Architecture BaseD on the powerful new family of Intel E5-2600 processors, Dell EMC Unity HybriD storage systems implement an integrateD architecture for block, file, anD VMware VVols with concurrent support for native NAS, iSCSI, anD Fibre Channel protocols. Each system leverages Dual storage processors, full 12 Gb SAS back end connectivity and Dell EMC’s patenteD multicore architecteD operating environment to Deliver unparalleleD performance & efficiency. AdDitional storage capacity is aDDeD via Disk Array Enclosures (DAEs) and for additional performance, online controller upgrades are available. Physical Specifications 300 400 500 600 Min/Max Drives 5/150 5/250 5/500 5/1000 Array Enclosure There are 2 versions: A 2U Disk Processor Enclosure (DPE) with twenty five 2.5” drives and a 2U Disk Processor Enclosure with twelve 3.5” Drives. Drive Enclosure (DAE - All moDels support 2U twenty five drive trays for 2.5” drives, 3U fifteen drive trays for 3.5” drives, anD 3U eighty drive Disk Array Enclosure) trays for 2.5” drives Dell EMC Unity systems are powereD by 2 power supplies (PS) per DPE/DAE.
  • SRM 6.9 Administrator Guide

    SRM 6.9 Administrator Guide

    ADMINISTRATOR GUIDE Storage Resource Monitor Version 6.9 Last Updated: Tuesday, June 4, 2019 © 2019 SolarWinds Worldwide, LLC. All rights reserved. This document may not be reproduced by any means nor modified, decompiled, disassembled, published or distributed, in whole or in part, or translated to any electronic medium or other means without the prior written consent of SolarWinds. All right, title, and interest in and to the software, services, and documentation are and shall remain the exclusive property of SolarWinds, its affiliates, and/or its respective licensors. SOLARWINDS DISCLAIMS ALL WARRANTIES, CONDITIONS, OR OTHER TERMS, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE, ON THE DOCUMENTATION, INCLUDING WITHOUT LIMITATION NONINFRINGEMENT, ACCURACY, COMPLETENESS, OR USEFULNESS OF ANY INFORMATION CONTAINED HEREIN. IN NO EVENT SHALL SOLARWINDS, ITS SUPPLIERS, NOR ITS LICENSORS BE LIABLE FOR ANY DAMAGES, WHETHER ARISING IN TORT, CONTRACT OR ANY OTHER LEGAL THEORY, EVEN IF SOLARWINDS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. The SolarWinds, SolarWinds & Design, Orion, and THWACK trademarks are the exclusive property of SolarWinds Worldwide, LLC or its affiliates, are registered with the U.S. Patent and Trademark Office, and may be registered or pending registration in other countries. All other SolarWinds trademarks, service marks, and logos may be common law marks or are registered or pending registration. All other trademarks mentioned herein are used for identification purposes only and are trademarks of (and may be registered
  • Dell Emc Vmax All Flash

    Dell Emc Vmax All Flash

    DELL EMC VMAX ALL FLASH Mission-Critical Storage at Scale All flash arrays are accelerating the pace of business transformation as IT ESSENTIALS professionals search for the most relevant technologies to modernize their Leverage advanced 3D NAND operation and drive down operational and capital expenditures. As flash prices flash to consolidate high-demand rapidly decline, capacity points exceed spinning disk, and data reduction transaction processing and techniques advance, more organizations are evaluating, testing, and deploying decision support workloads all-flash solutions to tackle the most demanding mixed workloads that span Achieve consistent 350 across the modern datacenter. microsecond response times at massive scale for extreme-growth Dell EMC VMAX All Flash arrays are architected to solve the CIO challenge of hybrid cloud environments embracing a modernized flash-centric datacenter for mission- critical applications while simultaneously simplifying, automating, and consolidating Process up to 6.7 million IOPS at sub-1ms latency with up to IT operations. VMAX All Flash is engineered for the latest, high density flash 576 CPU cores and multi- technology and to specifically exploit the rich set of data services of VMAX All threading technology Flash. These data services address the new requirements of the modern Accelerate time to deployment with datacenter while continuing to deliver the reliability and mission-critical streamlined appliance-based availability Dell EMC customers have relied on for years. packaging and easy non-disruptive
  • Asia Pacific

    Asia Pacific

    Enterprise Data Storage Market Insights Future Technologies and Trends Will Drive Market Growth P8CD-72 September 2015 Contents Section Slide Number Scope and Market Overview 3 Enterprise Storage Market Trends 7 Future Technologies in Storage 12 Business Models of Vendors 16 Business Models of OEMs 26 Business Models of Distributors 31 Implications of Storage Trends on Data Centers 39 Frost & Sullivan Story 45 P8CD-72 2 Scope and Market Overview Return to contents P8CD-72 3 Scope of the Study Objectives • To provide an overview of the global enterprise data storage market, focusing on the trends, technology, and business models of major market participants • To understand the trends affecting the global storage market and the implications of these trends on the data center market • Future technologies entering the storage market • To gain a detailed understanding on the distribution structure and channel partner program for key storage vendors EMC and NetApp • To provide an understanding of the business model for ODM/OEMs in terms of service and support capabilities across regions; these include Foxconn and Supermicro ODM: Original Design Manufacturer OEM: Original Equipment Manufacturer Source: Frost & Sullivan P8CD-72 4 Market Overview The enterprise data storage market is changing at a rapid pace. More data is being digitized than ever before and stored on disks of various size capacities. Globally, by 2020, there are expected to be about 26 billion connected devices. These devices would generate large amounts of data that need to be stored and analyzed at some point of time. Storage devices need to be agile, scalable, low cost, able to handle huge data loads, and durable to sustain the huge data growth.
  • VPLEX with Geosynchrony 5.0 Product Guide

    VPLEX with Geosynchrony 5.0 Product Guide

    EMC® VPLEX™ GeoSynchrony® 5.2 Product Guide P/N 302-000-037-01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.EMC.com Copyright © 2013 EMC Corporation. All rights reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS IS.” EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date regulatory document for your product line, go to the Technical Documentation and Advisories section on EMC Online Support®. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. All other trademarks used herein are the property of their respective owners. 2 EMC VPLEX Product Guide Contents Chapter 1 Introducing VPLEX VPLEX overview..................................................................................................... 14 VPLEX product family........................................................................................... 16 Mobility .................................................................................................................... 19 Availability..............................................................................................................
  • Dell EMC E20-393 Exam Dell EMC Implementation Engineer, Unity Solutions Specialist Exam

    Dell EMC E20-393 Exam Dell EMC Implementation Engineer, Unity Solutions Specialist Exam

    Dell EMC E20-393 Exam Dell EMC Implementation Engineer, Unity Solutions Specialist Exam Questions & Answers Demo Questions & Answers PDF Page 2 Version: 13.0 Question: 1 A storage administrator has requested a recommendation on upgrading their VNX5600 to a comparable Unity storage array. The solution requires a maximum capacity of 3.5 PB. To meet the administrator's requirement without over provisioning the capacity, which Unity Hybrid storage array is recommended? A. Unity 300 B. Unity 400 C. Unity 500 D. Unity 600 Answer: D Explanation: Unity 600 delivers 1.2 TB to 3.0 PB max raw capacity. Question: 2 What is the minimum VMware Hypervisor version a server must be running in order to support the deployment of a UnityVSA system? A. 4.0 B. 5.0 C. 5.5 D. 6.0 Answer: C Explanation: UnityVSA requirements include: VMWare ESXi 5.x, 6.x References: https://sweden.emc.com/products-solutions/trial-software-download/unity- vsa.htm Question: 3 Questions & Answers PDF Page 3 Which feature is supported on a UnityVSA operating environment? A. Asynchronous Replication B. MCC Write Caching C. Quick Start Pool Provisioning D. Data at Rest Encryption Answer: A Explanation: Asynchronous Unified Replication is available natively on UnityVSA. This allows file and block resources to be replicated between UnityVSA systems, between UnityVSA and physical Unity systems, and also locally back to the same UnityVSA system Question: 4 A storage administrator is creating a host profile in Unisphere to provide host access to block storage resources using the iSCSI protocol. The host initiators were not automatically discovered and must be manually added.
  • Dell EMC Unity: Data at Rest Encryption a Detailed Review

    Dell EMC Unity: Data at Rest Encryption a Detailed Review

    Technical White Paper Dell EMC Unity: Data at Rest Encryption A Detailed Review Abstract This white paper explains the Data at Rest Encryption feature, which provides controller-based encryption of data stored on Dell EMC™ Unity storage systems to protect against unauthorized access to lost or stolen drives or system. The encryption technology as well as its implementation on Dell EMC Unity storage systems are discussed. June 2021 H15090.6 Revisions Revisions Date Description May 2016 Initial release – Unity OE 4.0 July 2017 Updated for Unity OE 4.2 June 2021 Template and format updates. Updated for Unity OE 5.1 Acknowledgments Author: Ryan Poulin The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any software described in this publication requires an applicable software license. This document may contain certain words that are not consistent with Dell's current language guidelines. Dell plans to update the document over subsequent future releases to revise these words accordingly. This document may contain language from third party content that is not under Dell's control and is not consistent with Dell's current guidelines for Dell's own content. When such third party content is updated by the relevant third parties, this document will be revised accordingly. Copyright © 2016-2021 Dell Inc. or its subsidiaries. All Rights Reserved. Dell Technologies, Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc.
  • EMC Recover Point and VCE Vblock

    EMC Recover Point and VCE Vblock

    EMC Recover Point and VCE vBlock Solution for Continuous Data Protection-Replication in Heterogeneous Environments and integration with VCE vBlock solution Dejan Živanović PreSales Manager EMC Technology Solutions Group © Copyright 2009 EMC Corporation. All rights reserved. 1 IT Challenges for Information Protection Local, Remote or Local & Remote ? Business Technical Considerations Considerations Recovery and Cost consistency Functionality, Capacity availability Recovery time Bandwidth objectives Recovery point Performance objectives PRIMARY DECISION DRIVERS The right replication solution can overcome these challenges © Copyright 2009 EMC Corporation. All rights reserved. 2 Real Time Recovery Points & Recovery from Disaster Historical Backup: Recovery Point Every 24 Hrs Snapshots and Clones Continuous Data Protection Creates copies like “time-lapse photographs” Change-based “VIDEO CAMERA” with Snapshot / Clone Technology: Recovery Point Every 4-6 Hrs DVR-like roll back capabilities (A)Sync Replication with Gold Copy: Recovery Point 12- 24Hrs • Either space efficient change-based CDP Timesnapshots based CDP: for Timebackup indexed off-loading , but no event driven recovery points • Or full copies or clones for test and • Journal every change made and set development with minimal production the window for the amount of time to impact record CDP: Unlimited recovery points with application-aware I/O bookmarks Patch A Patch B Patch C Patch G Hot Backup VSS © Copyright 2009 EMC Corporation. All rights reserved. 3 RecoverPoint Configuration
  • Migrating to EMC Unity with SAN Copy

    Migrating to EMC Unity with SAN Copy

    MIGRATING TO DELL EMC UNITY WITH SAN COPY ABSTRACT This white paper explains how to migrate Block data from a CLARiiON® CX™ or VNX™ Series system to Dell EMC Unity™. This paper outlines how to use Dell EMC SAN Copy™ to easily perform the migration of Block devices, and includes simple, step-by-step instructions for the migration. October, 2017 WHITE PAPER The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any software described in this publication requires an applicable software license. Copyright © 2016 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners. Published in the USA [12/16] [White Paper] [H15164.2] Dell EMC believes the information in this document is accurate as of its publication date. The information is subject to change without notice. 2 TABLE OF CONTENTS EXECUTIVE SUMMARY ...........................................................................................................4 Audience ........................................................................................................................................... 4 USING SAN COPY TO MIGRATE TO DELL EMC UNITY .......................................................4