EARTH LEAKAGE CIRCUIT BREAKER

People Electric Appliance serves for people.

• ISO9001 ISO14001 OHSAS18001 DZ47LE EARTH LEAKAGE CIRCUIT BREAKER EARTH LEAKAGE CIRCUIT BREAKER

APPLICATION

DZ47LE earth leakage circuit breaker is used for the protection against electrical leaka ge in t he circuit of 50Hz or 60Hz, rated voltage single-phase 240V, 3-phase 415V, rated current up to 60A When somebody gets an electirc shock or the residual current of the circuit exceeds the fixe value, the ELCB can cut off the power within the time of 0.1s automatically protecting the personal safety and preventing the equipement from the fault resulted from the residual current. With this function, the ELCB can protect the circuit against overload and or can be used for the unfrequent switchover of the circuit under normal conditions. It conforms to IEC61009 standard. DZ47LE 1P SPECIFICATIONS

Leakage Leakage Leakage Rated Rated current Pole No action dead action Voltage(V) (A) current(mA) current(mA) time(s) 1~10 220V 1P 30 15 15~32 0.1

380V 2,3,4P 40~60 100 50

a.TH35-7.5 rail is used for the product installation. DZ47LE 2P b.Outline and installation dimensions(see the figure and the table)

Dimensions Type ABCDE DZ47LE-60/1N 46 70 40 45 94 DZ47LE-60/2 64 70 40 45 94 DZ47LE-60/3 91 70 40 45 94 DZ47LE-60/3N 100 70 40 45 94 DZ47LE-60/4 118 70 40 45 94

MAIN TECHNICAL DATA DZ47LE 3P

Single-pole Double-pole Triple-pole Triple-pole Four-pole double line double line triple line four line four line

DZ47LE DZ47LE DZ47LE DZ47LE DZ47LE C45LE C45LE C45LE C45LE C45LE 1 / 2 2 / 2 3 / 3 3 / 4 4 / 4

DZ47LE 4P

• B-01 RDX65LE EARTH LEAKGE CIRCUIT BREAKER EARTH LEAKGE CIRCUIT BREAKER APPLICATION

RDX65LE is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage single-phase 230V, 3 phase 400V, rated current up to 60A.Whe n so mebody gets an electric shockor the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time of 0.1s automatically to protect the personal safety and prevent the equipment from the fault resulted by the residual current. With this funtion, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions. It conforms to IEC61009. SPECIFICATIONS RDX65LE 1P Number of Poles 1P+N, 2P+N, 3P+N, 4P+N Rated voltage 240/415V Rated current 6A 10A 16A 20A 25A 32A 40A 50A 63A Rated Operating Current(mA) 30mA 100mA 300mA Rated non-operation (I n) 0.5I n Tripping Curve C,D

RDX65LE 2P RDX2LE-100 EARTH LEAKGE CIRCUIT BREAKER

APPLICATION

RDX2LE-100 is suitable for the circuit of 50Hz, rated voltage 230/400V, and rated curre nt u pto 100A . It has the earth leakage, overload & short circuit protect function. It can also add over voltage protect function. It is mainly used in buiding illumination and electrical distribution system. SPECIFICATIONS

Number of Poles 1P+N,2P+N,3P+N,4P+N Rated Current(A) 40,50,63,80,100 Rated Residual Operating Current(I n)(mA) 30,50,100,200,300 RDX2LE-100 2P+N Rated Residual Non-operation Current(I no)(mA) 0.5I n Rated Voltage(V) AC 230/400 Residual Current Off-time 0.1S Short Circuit Capacity(Icu) 3000A Endurance 4000 Tripping Curve C,D Portection Degree IP20 OVERALL AND MOUNTING DIMENSIONS(UNIT:MM)

108 3P+N 4P 108 4P 81 3P 81 70 RDX2LE-100 3P+N 3P 7.5 2P 54 2P 54 44 16 1P 27 35 27 81 45

L

• B-02 DZ47LE EARTH LEAKAGE CIRCUIT BREAKER EARTH LEAKAGE CIRCUIT BREAKER

APPLICATION

This products provide a high level of protection against earth leakage faults by the RCD in addition to the overcurrent and short-circuit protection offered by the MCB. This products are suitable for the protection of circuits with the highest safety requirements (i.e.eletctric apparatus in rooms with high humidity,socket circuits, rooms with bath bubs of shower etc.)

SPECIFICATIONS

Rated voltage 230/400V

Rated current 6A 10A 16A 20A 25A 32A 40A 50A 63A

Pole 1P+N 2P 3P 4P

Rated operating current (mA) 30mA 50mA 100mA 300mA

Rated non-operating (I N) 0.5I N

Tripping curve C type D type

Type Electronic

DZ65LE EARTH LEAKAGE CIRCUIT BREAKER

APPLICATION

This products provide a high level of protection against earth leakage faults by the RCD in addition to the overcurrent and short-circuit protection offered by the MCB. This products are suitable for the protection of circuits with higher safety requirements (i.e.electric apparatus in rooms with high humidity, socket circuits, rooms with bath bubs or shower etc.)

SPECIFICATIONS

Rated voltage 240/415V

Rated current 6A 10A 16A 20A 25A 32A 40A 50A 63A

Pole 1P 2P 3P 4P

Rated operating current (mA) 30mA 50mA 100mA 300mA

Rated non-operating (I N) 0.5I n

Tripping curve C type D type

• B-03 DXM3L(DZ30L) RESIDUAL CURRENT CIRCUIT BREAKER WITH OVER CURRENT PROTECTION EARTH LEAKAGE CIRCUIT BREAKER

APPLICATIONS

DXM3L(DZ30L) leakage protective breaker, DXM3L(DZ30L) (phase wire+neutral wire+leakage +overload voltage) protective breaker is used in the single phase residence circuit of AC.5 0Hz/ 60Hz , rat ed voltage 220V, used as electron shock protection. It can protect civil electron circuit from over load and short-circuit. This product has advantages of small volume, high breaking capacity Test Monthly zero, and live wires are cutted off at the same time, also protecting person from electric shock when the livewire connected opposite. This product conforms to IEC61009, Gb6829, GB/16917 .

DXM3L(DZ30L) PC60NL EARTH LEAKAGE CIRCUIT BREAKER

APPLICATION

The PC60NL RCCB incorporates a residual current operated electromagnetic release which operates without any auxiliary source of supply to open a circuit automatically in the case of an earth leakage fault between phase and earth greater than or equal to I n. The PC60NL combined with MCB & RCCB Provides: 1. protection against indirect contact 2. complementary protection against direct contact 3. protection for the installation against insulation faults

PC60NL PS250LE RESIDUAL CURRENT CIRCUIT BREAKER

APPLICATION

PS250LE RCBO is suitable for the circuit of 50/60Hz, rated volta ge 230/400V,and rated current up to 100A. It has the earth leakage, overload, short circuit protect function. It can also add over voltage protect function. It is mainly used in building illumination and electrical distribution system.

SPECIFICATIONS

PS250LE 2P Number of Pole 1P+N,2P,3P+N,4P Rated Current(A) 40,50,63,80,100 Rated Residual Operating Current(I n)(mA) 30,50,100,200,300 Rated Residual Non-operation Current(I n)(mA) 0.5I n Rated Voltage(V) AC 230/400 Residual Current Off-time 0.1S Short Circuit Capacity(Icu) 3000A Endurance 4000 Tripping Type C,D PS250LE 4P Protection Degree IP20 • B-04 RDX6LE-63 EARTH LEAKAGE CIRCUIT BREAKER EARTH LEAKAGE CIRCUIT BREAKER

ADVANTAGE

Earth leakage Circuit Breaker With Overcurrent Protection Electronic type Compact structure, small volume, (two modules in width) With short circuit, overload and residual current protection

RDX6LE-63 Action function has nothing to do with main circuit voltage With midline cut-off functions, it is safer and more reliable. With double functional connection terminals, it has strong connection ability. With contact state indicator, it is easy to recognize the contact situation. Different handle colors are used to indicate different rated current. High breaking capacity:10KA With wide range of rated current, it can be used as family main United accessories series Type can provent the error tripping caused by electric equipment RDX6LE-63 SPECIFICATIONS

Pole No. 2 P Standards IEC61009(EN61009)GB16917.1 Type C 6,10,13,16,20,25,32,40A Rated Current Type D 6,10,13,16,20A

Rated eakage Current I n 30,100mA Rated Voltage(Ue) 230V;50Hz Tripping Time G Minimum 10ms for prolonging

Sensitivity AC type Type 3 Breaking Capacity Icn 10KA Tripping Characteristic C,D RDX6LE-63 Grade of Protection IP40 Electric:no less than 4000 times Service Life Machanic:no less than 20000 times Wire 1-25 square micron Terminal Connection Bus-bar row thickness 0.8-2mm Shell width Din Rail 35mm(Two modulus in width)

MOUNTING DIMENSION

5.5 30.5 4.5 1P+N 1 N 45 80

9.5 2 N 44 35 60

• B-05 PID RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER

APPLICATION

PID RCCB is in conformity with the standard of IEC61008. The RCC B ca n cu t of f the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk ine. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for useing in varieties of plants and enterprises, buildings, constructions. It can be used in circuits up to 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use in DC pulse system. SPECIFICATIONS

Number of Pole 1P+N,3P+N Rated Current(A) 16,20,25,40,50,63 Rated Residual Operating Current(I n)(mA) 30,100,300,500 AC 230/240 Rated Voltage(V) PID 2P AC400/415 Residual Operating Current Scope 0.5I n~1I n Residual Current Off-time 0.3S Short Circuit Capacity(Icu) 6000A Endurance 4000 Protection Degree IP20

NORMAL OPERATION AND MOUNTING REQUIREMENT

Circumstance temperature-5 ~+40 ,average temperature not exceeding 35 . Altitude above sea level less than 2000m. Humidity not exceeding 50% at 40 and not exceeding 90% at 25 . Installation class or . Pollution class . Installation method DIN Rail mounting type. The external magnetism shall not be more than 5 times of terrestrial one. PID 4P Product shall be installed vertically at the place where there shall be no severe impact or vibration. The product is switched on when the handle is at upper position.

OVERALL AND MOUNTING DIMENSIONS(Unit:mm)

72 74.5 36

N N 65 65 85 O.OFF 85 O.OFF 35.5

N

• B-06 PID-N RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER

CONSTRUCTION AND FEATURE

Applicable to terminal and pin/fork type busbar connection Contact position indication High short-circuit current withstand capacity Provides protection against earth fault/leakage current and function of isolation Fire resistant parts endures abnormal heating and strong impact

••••••••• Equipped with finger protected connection terminals ••• • ••• • ••••• Automatically disconnect the circuit when earth fault/ leakage current occurs and exceeds the rated sensitivity. Independent of and line voltage, and free from external interference, voltage fluctuation.

PID-N 2P TECHNICAL DATA

Pole No.: 2, 4 Connection terminal: Rated current(A): 25, 40, 63 Screw terminal Rated voltage: 230/400V AC Pillar terminal with clamp Rated frequency: 50/60Hz Fastening torque: 2.0Nm Mode: electro-magnetic type, electronic type Installation: Residual current characteristics: A, AC On symmetrical DIN rail 35mm Rated making and breaking capacity: 630A Panel mounting Rated residual operating current I n(mA): 10, 30, 100, 300, 500 Rated residual non-operating current I no: 0.5I n ••••••••• ••• •••• • Rated conditional short-circuit current Inc: 6000A ••••• Rated conditional residual short-circuit Current I c: 6000A Tripping duration: instantaneous tripping 0.1s Residual tripping current range: 0.5I n~1I n Electro-mechanical endurance: 4000 cycles Connection capacity: Rigid conductor 25mm2 PID-N 4P WIRING DIAGRAM

• B-07 PF7 RESIDUAL CURRENT DEVICE RESIDUAL CURRENT DEVICE

APPLICATION

The RCD is in conformity with the standard of IEC61008, GB16916 and BS EN61008. The RCD can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line, thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCD is mainly suitable for using in variety of plants and enterprises, buildings constructions, commerces, guesthouses and families. It can be used in circuits up to single phase 230V, three phases 400V 50 to 60Hz. The RCD is not suitable for using on DC pulse system.

ELECTRICAL

PF7 2P Design according to ICE61008 (EN 61008) Tripping time undelayed min.10 ms delay min.40 ms delay with selective disconnecting function Rated voltage 230/400V; 50Hz Rated tripping current 10,30,100,300,500mA Sensitivity AC and pulsating DC Rated short 10KA with 63A gL back-up Circuit strength 10KA with 80A gL(F7-80 and-863) 6KA(rated current 63A) with 63A gL Maximum back-up fuse for 63A gL Short circuit protection 80A gL (F7-80 and-863) Maximum back-up fuse for 45A gL(F7-25 and-40A) PF7 4P Oveload protection 40A gL(F7-80 A) Resistance to climatic conditions according to IEC 61008 Degree of protection built-in switch IP 40 Endurance electrical comp. 4.000 operating cycles mech comp. 20.000 operating cycles MECHANICAL

Frame size 45mm Socket size 80mm Device width 35mm (2mod.), 70mm (4mod.)

••••••••• Mounting quick fastening with 2 lock-in Positions on DIN rail En50022 Upper and lower terminals open mouthed/lift terminals Terminal protection finger and hand touch safe, VBG 5, OVE-EN 6 Terminal capacity 1 --- 25mm2 ••••••••• Busbar thickness 0.8 - 2mm

DIMENSION (Units: mm)

•••••••••

•••••••••

• B-08 PNFIN RESIDUAL CURRENT DEVICE RESIDUAL CURRENT DEVICE

APPLICATION

PNFIN Residual Current Device(RCD) is in conformity with the standard of IEC61008, VDE 0664, CEE27 and BS4293. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. PNFIN RCD is mainly suitable for using in varieties of plants, enterprises, buildings, constructions, commerces, guesthouses and families. It can be used in circuits up to single phase 240V, three phases 415V, 50 or 60Hz. SPECIFICATIONS Type PNFIN25 PNFIN40 PNFIN63 PNFIN100 Rated current In (A) 25 40 63 100 PNFIN 2P Rated operating current for earth leakage I n(A) 0.03,0.1,0.3,0.5 0.1,0.3,0.5 Rated non-operating current for earth leakage I n(A) 0.5I n Voltage Un(V) 240(220)V 415(380)V Pole 2,4 MAIN TECHNICAL DATA In 2I n 0.25A(or5I n) Operating time(second) 0.2 0.1 0.04 Limited value of non-operating current for 2In balance load or unbalance load In minimum value of rated making and In=25 In=40 In=63 breaking capacity 200 300 400 PNFIN 4P Rated conditional short circuit current Inc(A) 1500 2000 3000 Endurance(times) 4000

PFIN RESIDUAL CURRENT DEVICE

APPLICATION

PFIN Residual Current Device(RCD) is in conformity with the standard of VDE 0664, CEE27 and BS4293. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. PFIN ELCB is mainly suitable for varieties of plants and enterprises, buildings, constructions, commerces, hotels and families. It can be used in circuits up to single phase 240V, three phases 415V, 50 or 60Hz. PFIN 2P MAIN TECHNICAL DATA In 2I n 0.25A(or5I n) Operating time(second) 0.2 0.1 0.04 Limited value of non-operating current for 2In balance load or unbalance load In minimum value of rated making and In=25 In=40 In=63 breaking capacity 200 300 400 Rated conditional short circuit current Inc(A) 1500 2000 3000 Endurance(times) 4000 SPECIFICATION Type PFIN25 PFIN40 PFIN63 PFIN100 Rated current In (A) 25 40 63 100 PF1-4P Rated operating current for earth leakage I n(A) 0.03,0.1,0.3,0.5 0.1,0.3,0.5 Rated non-operating current for earth leakage I n(A) 0.5I n Voltage Un(V) 240(220)V 415(380)V Pole 2,4 • B-09 PF360 RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER

APPLICATION

The RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard of earth leakage of trunk line. Thus, it is suita ble to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for useing in varieties of plants and enterprises, buildings constructions. It can be used in circuits up to 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC pulse system. SPECIFICATION

Number of Pole 2P,4P Rated Current (A) 16,20,25,32,40,50,63,80,100 Rated Residual Operating Current (I n)(mA) 10,30,100,300,500 Rated Residual Non-operation Current (I no)(mA) 0.5 I n PF362 2P AC 230/240 Rated Voltage (V) AC 400/415 Residual Operating Current Scope 0.5I n~1I n Residual Current Off-time 0.3S Short Circuit Capacity (Icu) 3000A Endurance 4000 Protection Degree Ip20

OPERATION PRINCIPLE

1 3 1 357N

I > I >

PF364 4P 2 4 2 468N

OVERALL AND MOUNTING DIMENSIONS (UNIT: MM)

69

68 35 70 44 17.5 17.5 17.5 17.5 17.517.5 17.5 17.5 6.3 2 2 2 2 71 71 46 46 90.4 90.4 90.4

7.5 7.5

• B-10 PR RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER

DESCRIPTION

To open a circuit automatically in case of an earth leakage fault between phase and earth and / or neutral greater or equal to 10mA, 30mA, 100mA, 300mA or 500mA. It is used in domestic, commercial and industrial installations. EARTH FAULT INDICATOR

Mechanical indicator appearing on the front face of the RCCB is to be differed between tr ipping and off position yellow-tripped. NUISANCE TRIPPING PRC 2P All the RCCBs are protected against transient voltages (lightening, line disturbances)and transient currents (from high capacitive circuits) DC sensitive RCCBs or time delay devices are available, please consult us you also have the possibiliy to install the following accessories: electrical cover kit, locking kit. Sensitivity Pole Current rating cat.ref. High sensitiviy:10mA 2 16A PRC216B 2 25A PRC225B

30mA 2 16A PRCD216B 2 25A PRCD225B 2 40A PRCD240B 2 63A PRCD263B 2 80A PRCD280B 2 100A PRCD284B PRC 4P 4 25A PRCD425B 4 40A PRCD440B 4 63A PRCC463B 4 80A PRCD480B Medium sensitivity:100mA 2 25A PRCE225B 2 40A PRCE240B 2 63A PRCE263B 2 80A PRCE280B 2 100A PRCE284B 4 25A PRCE425B 4 40A PRCE440B 4 63A PRCE463B 4 80A PRCE480B Low sensitivity:300mA 4 100A PRCE484B 2 25A PRCF225B 2 40A PRCF240B 2 63A PRCF263B 2 80A PRCF280B 2 100A PRCF284B PRCC 2P 4 25A PRCF425B 4 40A PRCF440B 4 63A PRCF463B 2 80A PRCF480B 2 100A PRCF484B Low sensitivity:500mA 2 25A PRCG225B 2 40A PRCG240B 2 63A PRCG263B 2 80A PRCG280B 2 100A PRCG284B 4 25A PRCG425B 4 40A PRCG440B 4 63A PRCG463B 4 80A PRCG480B 4 100A PRCG484B Terminal cover kit: For RCCBs2 16 to 63A 10 sets PRCZ005 PRCC 4P (1 se = 2 covers) For RCCBs4 16 to 63A 10 sets PRCZ006 For RCCBs2 80 to 100A 10 sets PRCZ007 For RCCBs4 80 to 100A 10 sets PRCZ008

• B-11 PR101 RESIDUAL CURRENT CIRCUIT BREAKER EARTH LEAKAGE CIRCUIT BREAKER

APPLICATION

PR101 Series Earth Leakage Circuit Breakers apply to in AC circuit of frequency of 50 Hz, rated voltage up to 415V, ratedcurrent up to 80A. It is mainly use d as an indi rect con tact protection fot human. It also can be used to preven t against the fire danger caus ed b y ea rth falt current owing to equipment insulation damage. When the protective measures of the electric shock are out of work, the RCCB whose rated residual operating current less than 30mA can serve as the supplementary protection for in direct contact, but it can t be used as the sole direct contact protection.

PRODUCT FEATURES

1. PR101 Series Leakage Circuit Breakers are the protector for pure electromagnetic residual current operation. PR101 2P 2. The operation function is unrelated to circuit voltage, but operation is reliable. 3. It can be reliably operated on the loss of phase or neutral. 4. The capacity of resisting electromagnetic interference is strong.

MAIN TECHNICAL DATA

Un Im Inc In In Ino The maximum of break-time(s) Type Hz (V) Im Im A mA mA I N 2I N 5I N 0.25A 500A 30 15 0.2 0.1 - 0.04 0.04 500A 50 25 0.2 0.1 - 0.04 0.04 (In 6,10, PR101 50A 16,25, 75 40 0.2 0.1 - 0.04 0.04 2P 240 6000A 32,40, 10In) 100 50 0.2 0.1 0.04 - 0.04 (In 50,63 50A) 80 300 150 0.2 0.1 0.04 0.04 0.04 50, 500 250 0.2 0.1 0.04 0.04 0.04 60 30 15 0.2 0.1 - 0.04 0.04 500A 50 25 0.2 0.1 - 0.04 0.04 (In 6,10, PR101 4P PR101 50A 16,25, 75 40 0.2 0.1 - 0.04 0.04 4P 415 6000A 32,40, 10In) 100 50 0.2 0.1 0.04 - 0.04 (In 50,63 50A) 80 300 150 0.2 0.1 0.04 0.04 0.04 500 250 0.2 0.1 0.04 0.04 0.04 DIMENSIONS

45

91 72 54 376.5 43.7 T 36 T

TH35

90 L1 L2 L3 Y1Y2 N PE 135N 45 90 I M 2/1 4/3 6/5N/N A W1 T B 180 44 12-6672 246N 64 • B-12 PBV-D RESIDUAL CURRENT CIRCUIT BERAKER RESIDUAL CURRENT CIRCUIT BREAKER

ELECTRICAL DATA

Design according to IEC 61008 (EN 61008) Tripping time undelayed min.10 ms delay min.40 ms delay with selective disconnecting function Rated voltage 230/400V; 50Hz Rated tripping current 10,30,100,300,500mA Sensitivity AC and pulsating DC Rated short 10KA with 63A gL back-up fuse Circuit strength 10KA with 80A gL (F7-80 and -863) 6KA(rated current 63A)with 63A gL Maximum back-up fuse for 63A gL PBV-D 2P Short circuit protection 80A gL(F7-80 and 863) Maximum back-up fuse for 45A gL(F7-25 and -40A) Overload protectiton 40A gL(F7-80 A) Resistance to climatic conditions according to IEC 1008 Degree of protection built-in switch IP 40 Endurance electrical comp. 4.000 operating cycles mech comp 20.000 operating cycles

MECHANICAL DATA

Frame size 45mm Socket size 80mm Device width 35mm (2mod.), 70mm (4mod.) PBV-D 4P Mounting quick fastening with 2 lock-in Positions on DIN rail En50022 Upper and lower terminals open mouthed/lift terminals Terminal protection finger and hand touch safe, VBG 5, OVE-EN 6 Terminal capacity 1 --- 25mm2 Busbar thickness 0.8 - 2mm

• B-13 PG RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER

APPLICATION

PG RCCB, rated current is adjustable from 10A up to 60A. User can select suitable current for better protection against overload and short-circuit. The products comply with IEC61008.

SPECIFICATIONS

Number of Pole 24 Rated Voltage(V) 250/440 PG230 Rated Current(A) 10,15,20,30,45,50,60A Adjustable Leakage Motion Current(mA) 300,500 300,500 Leakage Dead Current(mA) 150,250 150,250

DIMENSION (Units: mm)

N1 N321

PG430 210 210

53 53 70 70 115 70

TG RESIDUAL CURRENT CIRCUIT BREAKER

APPLICATION TG230 TG RCCB, rated current is adjustable from 10A up to 60A. User can select suitable current for better protection against overload and short circuit.The products comply with IEC61008.

SPECIFICATIONS

Number of Pole 24 Rated Voltage(V) 250/440 Rated Current(A) 10,15,20,30,45,50,60A Adjustable Leakage Motion Current(mA) 300,500 300,500 TG430 Leakage Dead Current(mA) 150,250 150,250

• B-14 PL9 RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER

APPLICATION

PL9 Residual Curren t De vice is in conformity with the standard of IEC61008. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk l ine. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. PL9 RCD is mainly suitable for using in varieties of plants, enterprises, buildings, constructions, commerces, guesthouses and families. It can be used in circuits up to 1phase 230V and 3 phases 400V 50/60Hz.

SPECIFICATIONS PL9 2P

Number of Pole 2P,4P Rated Current(A) 40,50,60 Rated Residual Operating Current(I n)(mA) 30,100,300 Rated Residual Non-operation Current(I n)(mA) 0.5I n Rated Voltage(V) AC 230/400 Residual Current Off-time 0.1S Short Circuit Capacity(Icu) 3000A Endurance 4000 Protection Degree IP20 PL9 4P

SPECIFICATIONS

Type PDBR230 PDBR430

Poles 2P 4P

Rated voltage(V) 250V/440V PDBR230 2P

Rated current(A) 5A-15A,10-30A,30-60A Adjustable

Leakage motion current(mA) 300mA 500mA 1000mA

Leakage dead current(mA) 150mA 250mA 500mA

Accord with standand NFC61450 PDBR430 4P

• B-15 CBT EARTH LEAKAGE CIRCUIT BREAKER EARTH LEAKAGE CIRCUIT BREAKER

USAGE

CBT Residual Current Circuit Breaker without ov er curr ent prot ecti on conforms to the standard of GB16916.1, IEC61008, BS4293 etc. It is used in the circuits of AC50~60Hz, single phase 230V(220V), three phases 400V(380 V) i n in dus tri al & m ini ng ente rpri ses, comm erc ial buildings and housing for protection of personal electric shock hazard and electric equipment and for unfrequent switchover of circuits under normal conditions.

INSTRUCTIONS

This RCCB is intended for installation within an enclosure in an ambient temperature between -5 and 40 with an average value not exceeding 35 over a 24 hours period. It should not be

CBT 2P installedat an altitude greater than 2000m above sea level, nor in an atmosphere subject to excessive pollution by smoke, dust, chemical fumes, salt laden spray, prolonged periods of high humidity or other abnormal conditions. See current product catalogues for a wide range of suitable enclosure.

PL13 EARTH LEAKAGE PROTECTING DEVICE

SPECIFICATION

PL13-01 Conforms with UL standard 943 CLASS A(GFCI and 498 receptacle). Protects against fault shock hazard from frayed wiring, damaged appliances, wherever electrical contact might provide a path to ground through human body. Can be wired to provide 20 amp GFCI feed-through protection to other outlets on outlets on the same circuit. Overload and neutral line error grounding protection. Trip thresholds of 4~6 milliamps. Unit trips within 0.025 seconds of fault detection. Operate within -35 ~66 environmental temperature. Protect against 10~450MHz voice interference. PL13-02 Made of high impact termoplastic to resist da mage fr om impa ct a nd f requ ent use. And with unbreakable nylon wall plate. Back and side wiring terminals permit fast installation. Clearly marked line and load terminals. Incorporate dual bolt terminal and installation screws w hich accept standard screw driver blades. The voltage and frequency of the product can be designed as per customers different repuirements.

PL13-03

• B-16 GFCI RECEPTACLE RECEPTACLE

DESCRIPTION ART.NO. BODY COLOR BUTTON COLOR

GFCI, Duplex PTG15-L-2AL ALMOND RED RESET/ Receptacle With red PTG15-L-2DE DEEP-ALMOND BUTTON TEST Reset Button and blue PTG15-L-2BL BLACK Test button 20A, 125V PTG15-L-2GR GRAY AC, 60Hz, PTG15-L-2IV IVORY With LED light PTG15-L-2WH WHITE Indicator

PTG15-L

DESCRIPTION ART.NO. BODY COLOR BUTTON COLOR

GFCI, Duplex PTG20-L-1AL ALMOND ALMOND Receptacle Buttons PTG20-L-1DE DEEP-ALMOND DEEP-ALMOND Match body face color PTG20-L-1BL BLACK BLACK 20A, 125V AC, 60Hz, PTG20-L-1GR GRAY GRAY With LED light PTG20-L-1IV IVORY IVORY Indicator PTG20-L-1WH WHITE WHITE

PTG20-L

DESCRIPTION ART.NO. BODY COLOR BUTTON COLOR

GFCI, Duplex PTG20-L-2AL ALMOND RED RESET/ Receptacle With red PTG20-L-2DE DEEP-ALMOND BUTTON TEST Reset Button and blue PTG20-L-2BL BLACK Test button 20A, 125V PTG20-L-2GR GRAY AC, 60Hz, PTG20-L-2IV IVORY With LED light PTG20-L-2WH WHITE Indicator

PTG20-L 3 Grace Switch can control resistance and inductance load which meets residential use and commercial use for its reliability and unique performance. Switch Characteristics

Large head double-drive combination screws for quick wiring Back and side wire connection are easy to be installed Green grounding screw Choice of different color

• B-17 GFCI RECEPTACLE RECEPTACLE

DESCRIPTION ART.NO. BODY COLOR BUTTON COLOR

GFCI, Duplex PTG15-2AL ALMOND RED RESET/BUTTON TEST Receptacle With red PTG15-2DE DEEP-ALMOND Reset Button and blue PTG15-2BL BLACK Test button 20A, 125V PTG15-2GR GRAY AC, 60Hz, PTG15-2IV IVORY PTG15-2WH WHITE

PTG15

DESCRIPTION ART.NO. BODY COLOR BUTTON COLOR

GFCI, Duplex PTG20-1AL ALMOND ALMOND Receptacle Buttons PTG20-1DE DEEP-ALMOND DEEP-ALMOND Match body face color PTG20-1BL BLACK BLACK 20A, 125V AC, 60Hz. PTG20-1GR GRAY GRAY PTG20-1IV IVORY IVORY PTG20-1WH WHITE WHITE PTG20

DESCRIPTION ART.NO. BODY COLOR BUTTON COLOR

GFCI, Duplex PTG20-2AL ALMOND RED RESET/ Receptacle With red PTG20-2DE DEEP-ALMOND BUTTON TEST Reset Button and blue PTG20-2BL BLACK Test button 20A, 125V PTG20-2GR GRAY AC, 60Hz, PTG20-2IV IVORY PTG20 PTG20-2WH WHITE

DESCRIPTION ART.NO. BODY COLOR BUTTON COLOR

GFCI, Duplex PTG15-L-1AL ALMOND ALMOND Receptacle Buttons PTG15-L-1DE DEEP-ALMOND DEEP-ALMOND Match body face color PTG15-L-1BL BLACK BLACK 15A, 125V AC, 60Hz. PTG15-L-1GR GRAY GRAY PTG15-L With LED light PTG15-L-1IV IVORY IVORY indicator PTG15-L-1WH WHITE WHITE

• B-18 GFCI RECEPTACLE RECEPTACLE

PTM-1 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK

DESCRIPTION ART. N0. COLOR

Single-pole Toggle PTM-1AL ALMOND Switch With PTM-1DE DEEP-ALMOND Grounding Screw PTM-1BL BLACK Quick Wiring and PTM-1GR GRAY Side Wiring PTM-1IV IVORV PTM-1WH WHITE

PTM-2 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES

DESCRIPTION ART. N0. COLOR

3-Way Toggle PTM-2AL ALMOND Switch With PTM-2DE DEEP-ALMOND Grounding Screw PTM-2BL BLACK Quick Wiring and PTM-2GR GRAY Side Wiring PTM-2IV IVORV PTM-2WH WHITE

PTM-3 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES

DESCRIPTION ART. N0. COLOR

Single-pole PTM-3AL ALMOND Decorative Switch PTM-3DE DEEP-ALMOND Screw Quick PTM-3BL BLACK Wiring and Side PTM-3GR GRAY Wiring PTM-3IV IVORV PTM-3WH WHITE

PTM-4 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES

DESCRIPTION ART. N0. COLOR

3-WayDecorative PTM-4AL ALMOND Switch With PTM-4DE DEEP-ALMOND Grounding Screw PTM-4BL BLACK Quick Wiring and PTM-4GR GRAY Side Wiring PTM-4IV IVORV PTM-4WH WHITE

• B-19 GFCI RECEPTACLE RECEPTACLE

RECEPTACLE CHARACTERISTICS

Additional assembly screw Side wire connection and 8 holes back quick wire connection Choice of different color Green grounding screw Large head double-drive combination screws for quick wiring

DESCRIPTION ART. N0. COLOR

PTMSR-15/1J-AL PTMSR-15/1-AL PTMSR-15/1JED Standard Duplex PTMSR-15/1ED ALMOND Receptacle 15A, PTMSR-15/1JBL DEEP-ALMOND 125V AC PTMSR-15/1BL BLACK With 1J , for PTMSR-15/1JGR GRAY PTMSR-15/1J Self-grounding PTMSR-15/1GR IVORV Clip PTMSR-15/1JIV WHITE 1 for Standard wire PTMSR-15/1IV PTMSR-15/1JWH PTMSR-15/1WH

DESCRIPTION ART. N0. COLOR

PTMSR-15/2J-AL PTMSR-15/2-AL PTMSR-15/2JED Standard Duplex PTMSR-15/2ED ALMOND Receptacle 15A, PTMSR-15/2JBL DEEP-ALMOND 125V AC PTMSR-15/2BL BLACK With 2J , for PTMSR-15/2JGR GRAY Self-grounding PTMSR-15/2GR IVORV PTMSR-15/2J Clip PTMSR-15/2JIV WHITE 2 for Standard wire PTMSR-15/2IV PTMSR-15/2JWH PTMSR-15/2WH

• B-20