FINAL REPORT

Non-Destructive Imaging Of Worn-off Hallmarks and Engravings From Metal Objects of Art Using Scanning Acoustic Microscopy

GRANT NUMBER MT-2210-0-NC-21

November 15, 2004

By

Paul L. Benson and Robert S. Gilmore TABLE OF CONTENTS

EXECUTIVE SUMMARY ...... 2

PART 1 INTRODUCTION ...... 3 1.1 Historical Development of Acoustic Imaging ...... 5

PART 2 METHODS AND MATERIALS...... 7 2.1 Theoretical Background...... 7 2.1.1 Stress Annealing ...... 7 2.1.2 Anisotropy...... 8 2.2 Coupling Fluid ...... 9 2.3 Acoustic Transducers...... 10 2.4 The Scanning Acoustic Microscope ...... 11 2.5 Initial Experimentation ...... 11 2.5.1 Sterling Silver Coupons ...... 11 2.5.2 Gold Coupons ...... 13 2.6 Objects Scanned...... 14

PART 3 RESULTS ...... 16 3.1 Sterling Silver Handle...... 16 3.2 Sterling Silver Fish Knife Blade ...... 17 3.3 Dessert Knife ...... 20 3.4 Apostle Spoon...... 20 3.5 Sterling Silver Fork...... 21 3.6 American Silver Dime ...... 22 3.7 English Teaspoon...... 23

PART 4 DISCUSSION ...... 23

PART 5 CONCLUSIONS ...... 25

PART 6 ACKNOWLEDGMENTS ...... 26

PART 7 REFERENCES ...... 26

PLATES………………...... 28

1 EXECUTIVE SUMMARY

The goal of this project was to determine if worn-off or illegible hallmarks on silver and gold works of art could be imaged using scanning acoustic imaging techniques. The project was quite successful, up to a point, and represents the first time acoustic images have been made of remnant deformation in silver and gold objects of art.

This imaging technique utilizes the residual plastic deformation left in the metal after the hallmarks or engravings have been struck to form a sonogram image representing the differences in the acoustic response of the struck area and the surrounding metal. Theoretically, this should be possible based on the calculated degree of anisotropy and the stress annealing temperature of both silver and gold. In practice, these residual stresses in gold of the historical alloys of 18K-22K (75%-92% gold) could not be imaged while silver, of various experimental alloys, did yield good images.

Numerous combinations of coupling fluids, lens geometries, and sound frequencies were tried in both surface-wave and back-wall imaging modes. In the end, FC-40 (an inert fluorocarbon liquid) used in the surface-wave imaging mode with an input frequency of 20 MHz through an F/1 lens produced the best results. These then are the recommended materials and parameters for imaging worn-off marks on silver and gold when using a scanning acoustic microscope.

Hallmarks and engravings from a total of twenty-six silver, two gold, and one copper alloy (bronze) objects were imaged during the two-year course of the project. Multiple images were made of the marks on these objects so that well over one hundred images were made during the project. The silver objects ranged in age from the 17th to the 20th centuries, the gold objects were modern coupons, and the one bronze object was a coin dating from the 1790’s. The silver content of the objects ranged from 80-95% silver while the gold objects were of 18K and 22K. The silver objects examined came from the collections of the Nelson-Atkins Museum of Art, private collections, and from purchases from dealers.

Imaging of worn-off or illegible hallmarks and engravings was successful one hundred percent of the time when residual flow was still present in the metal. Searches of the available literature on hallmarking techniques and consultations with silversmiths and the Superintendent Assayer of the Worshipful Company of Goldsmiths in revealed that heat was probably used during most of the final cleaning and shaping processes of silver objects after the hallmarks were applied. It now appears that in most cases the heat was sufficient to anneal the metal, thus eliminating the residual plastic flow. In these situations there was nothing to image except metal grain structure. Unfortunately, there are no visual clues on the surface of the metal to indicate whether the requisite plastic flow is still present in the subsurface.

2 1. INTRODUCTION

The use of hallmarks on silver has a long history dating back to the fourth century AD and represents the oldest known form of consumer protection. A series or system of five marks has been found on Byzantine silver dating from this period though their interpretation is still not completely resolved (Dodd, 1961). Figure 1. Typical set of English hallmarks indicating Hallmarking of European silver probably that the object is made of Sterling quality silver, originated in France in the 13th century and made by Hester Bateman in London in the year 1787, spread from there to other countries. The and a duty has been paid on the finished piece. alloy that is today universally recognized as ‘sterling silver’ (92.5% silver) originated in Hallmarks on silver and gold objects can fix an English statute of 1300 and was based on these pieces in history by providing direct the alloy of the English silver coinage in use evidence of the maker, the place and date of at that time. The English gold alloy manufacture, and the quality of the metal standard was based on an existing alloy alloy at a particular time. To some extent standard known as the “Touch of Paris” or then the historic, monetary, and intrinsic 19.2 carats/ 80% gold (Hare, 1978). In value of the objects are directly linked to the contrast to these long established standards, ability to discern the hallmarks. Silver’s the American standards were not formalized susceptibility to tarnishing means that it until 1906. must to be polished regularly to maintain its desired bright metallic surface finish. The As hallmarks were a form of consumer polishing process removes a thin layer of protection there were strict penalties for silver metal so that over time the hallmarks their misuse. For example, a goldsmith will be gradually reduced to the point where could have his substandard wares seized, he they are either illegible or completely worn could be fined, jailed, maimed, banished, or away, resulting in the loss of valuable even put to death (Jackson, 1921). historic information. The ability to read the original marks would greatly aid in placing The complete history of European these objects back into their rightful place in hallmarking of silver and gold is far from history. complete as some historical records have been lost through time. For example, the Even though the hallmark may be London guildhall records prior to1681 were completely worn away, there may still be lost in a fire at the Assay Office, and in sufficient residual plastic deformation within Holland records were destroyed when the the metal from the original act of striking the guild system was abolished in 1807. As the surface to create an image of the vanished history and standards of hallmarking silver hallmark. This residual deformation can be and gold objects from various countries is characterized in the form of an acoustic complex, it should be consulted on an response when the surface is insonified with individual basis (Figure 1). a focused acoustic beam; the amplitude of the response is then used to create an image on a computer screen. The highly polished

3 silver surface provides a nearly ideal procedure in law enforcement forensic medium for the utilization of acoustic laboratories. Unfortunately, all of these imaging techniques. As a general rule, the techniques are destructive to the metal to surface roughness of the material to be some extent (Table 1). The most common imaged should be less than one-third the technique involves polishing the area to be wavelength of the input acoustic frequency imaged then etching the surface with an acid to provide sufficient returned energy to to bring out the latent serial numbers; produce an image; when the surface needless to say, the use of this technique roughness exceeds this parameter there is would not be tolerated on works of art. The too much surface scattering of the acoustic newly developed acoustic imaging signal to produce a meaningful image. procedure is non-contact and does not harm the metal in any way. It is the only known Other methods have been successfully non-destructive technique that has the employed to images worn-off information potential to recover lost information from from metal. Recovery of filed-off serial silver and gold works of art. numbers from firearms is a well-established

Table 1. (compiled from Treptow, 1978)

4 1.1 Historical Development of Acoustic Imaging limited the industrial usefulness of scanning acoustic microscopy except for The ultrasonic imaging technologies for microelectronic assemblies. However, the visualizing the surfaces and interiors of near optical resolution of the acoustic opaque solids are well established (Gilmore, microscope images provided a new 1999). Between 1929 and 1931, Sokolov emphasis and enthusiasm for ultrasonic and Mulhauser independently proposed the imaging in general. This renewed effort, use of ultrasonic waves to form images of combined with the collateral advances in the the interior of materials for materials computational power, storage, and display characterization and nondestructive capabilities of small computers, resulted in evaluation (NDE). During the 1930’s all three decades of rapid progress in ultrasonic efforts to develop ultrasonic images imaging devices, methods and applications. involved the development of acoustic By the start of the 21st century ultrasonic amplitude sensitive screens that displayed imaging methods were well established to visible contrast in proportion to the acoustic characterize material microstructures, bonds, amplitude incident on the screen. These defects (flaws, voids, cracking, porosity, image converter screens (such as the layer delaminations), coating delaminations, Pohlmann Cell and the Sokolov Tube) had elastic modulus and density variations, heat such poor sensitivity and resolution that affected zones in welds and other fusion little use was made of them other than as processes, stress distributions in isotropic curiosities. Pulse-echo and pulse- materials, and in vitro carious lesions. transmission C-Scan images, using both Materials examined include ceramics, focused and unfocused ultrasonic beams, composites, glass, metals and alloys, were introduced in the early 1950’s. The polymers, plastics, semiconductors, primary use was for industrial NDE. These electronic components, geological materials, initial C-Scan images were displayed on coffee and soybeans, bone, teeth, soft photographic or voltage sensitive paper and biological tissue, and organic compounds. were acquired by scanning a single However, a recent literature search has transducer back and forth over the subject found only three references to the use of material. The image was built up line by acoustic microscopy for evaluating metal or line. By the early 1970’s ultrasonic C-Scan ceramic art objects (Stravoudis, 1989; inspections of both the surfaces and interior Benson, 1991; Ouahman, 1995). volumes of industrial materials were in general use and C-Scan images had been Several texts are available that clearly produced as high as 50 MHz in frequency. describe ultrasonic imaging and acoustic In the early 1970s work at Stanford microscopy (Lemons and Quate, 1979; University under the direction of C.F. Quate Briggs, 1982; Gilmore, 1999); therefore the (Lemons and Quate, 1979) combined zinc characteristics and operation of the systems oxide on sapphire transducers, C-Scan data will only be summarized here. A typical acquisition, and microwave electronics to transducer used for acoustic imaging create very small ultrasonic images at GHz consists of a piezoelectric layer cut to a frequencies. These images rivaled optical specified frequency and bonded to a plano- microscopy in resolution, detail, and field of concave lens to focus the ultrasonic beam. view; therefore, the devices that made them For high frequency operation the lens is were called Scanning Acoustic Microscopes. usually fabricated from single crystal The GHz frequencies, low depths of sapphire or fused quartz. Alternatively, penetration, and very small fields of view eliminating the lens and spherically curving

5 the piezoelectric layer itself can also focus the ultrasonic beam. In the case of pulse-echo C- Scan data acquisition, the transducer acts as both the transmitter and receiver of the acoustic energy. A short electrical pulse is applied to the piezoelectric layer to create the acoustic pulse and return acoustic echoes interact with the layer to create electrical signals. The object to be scanned is placed at the focal point of the ultrasonic beam. What makes the acoustic microscope unique is the Figure 3. Cross-sectional view of deformation in ability to place the focal point of the acoustic stamped hallmark. Slip lines, twinning bands, and energy either on the surface of the object or smaller grain size result where metal absorbs subsurface in the object’s interior. Again, as stamping compression (shown by arrows). From Treptow, 1978. with all C-Scan type data acquisition, the image is acquired by raster scanning the In the specific case of imaging worn ultrasonic beam and acquiring echo hallmarks, it has been demonstrated that amplitudes at an increment along the scan images of the residual deformation in the lines equal to the line-to-line spacing (Figure 2). metal from the stamping process can be obtained by two methods: (1) Backwall or back surface imaging where an acoustic beam is focused through the full thickness of the silver and on the back surface containing the hallmark deformation (Figure 4a); (2) Surface wave imaging of the surface containing the hallmark deformation (Figure 4b). In other words, surface waves are used to produce images of the entry surface, i.e., the struck surface, whereas backwall images are obtained from the surface opposite to the Figure 2. Schematic of an ultrasonic imaging struck surface. system; higher frequencies and higher image magnification would make the same schematic an acoustic microscope.

(a) (b) The contrast changes in acoustic images are produced by variations of elasticity, density, and acoustic attenuation within the material being imaged. When the hallmark is applied by striking the surface of the metal, a localized change in the silver’s physical properties occurs. Some of these properties that are altered include yield strength, tensile strength, hardness, and ductility. Any or all of these Figure 4. Schematic showing (a) back surface changes effects the acoustic attenuation of the reflection imaging (or backwall imaging) and (b) insonified signal directly under and in near mode converted surface wave imaging. proximity to the struck area (Figure 3).

6 Only that part of the reflected signal that choosing the proper reflection to gate and corresponds with the surface of interest is process requires experimentation and used to create the image; this process is experience on the part of the operator to referred to as ‘gating’ (Figure 5). Correctly obtain a properly resolved image.

Figure 5. A typical acoustic pulse showing a ‘gate’ around that portion of the pulse to be processed to form an image. (source of image unknown)

2. METHODS AND MATERIALS silver migrate and the microstructure entirely recrystallizes. Any residual plastic 2.1 Theoretical Background flow remaining from striking a hallmark would begin to relax at the stress annealing 2.1.1 Stress Annealing temperature and could totally disappear during recrystallization. Since the melting A first step in determining if the amount of o residual deformation in silver or any other point (Mp) of sterling silver is 893 C (1166oK) the stress annealing temperature material is sufficient for acoustic imaging is o to determine the stability of this deformation would be approximately 0.4 x 1166 K = 466oK, or approximately 93º above the over time. The lowest temperature that o might affect this stability is the residual boiling point of water (100ºC or 373 K). stress annealing temperature. This Room temperature is typically approximated at 300oK; since the lowest critical temperature is generally considered to be o approximately 4/10ths (0.4) of the absolute temperature for sterling silver (466 K) is melting temperature as expressed in degrees well above this temperature, it seems Kelvin (oK) (Callister, 2003). The highest reasonable to expect the residual temperature below the melting point deformation produced by a hallmark stamp affecting the retention of the deformation is to be relatively stable over a few hundred less exact, but is in the range of years of time, even if repeatedly washed in temperatures at which recrystallization hot water. Stress annealing temperatures for occurs. Here the grain boundaries in the other metals are given in Table 2.

7 Table 2. Approximate Stress Annealing Temperatures for Various Metals RATIO OF STRESS ANNEALING MELTING POINT (MP) IN MAX AMBIENT METAL TEMPERATURE IN DEG. DEG. CELSIUS TEMPERATURE TO MP IN CELSIUS DEG. KELVIN* Gold** 24K 1063 261 0.24 22K 1003 237 0.25 18K 905 198 0.27 14K 845 173 0.28 Silver pure 962 221 0.25 Sterling 863 193 0.27 Copper 1082 269 0.23 Lead 327 -33 0.50 Bronze 10% tin 1005 238 0.25 20% tin 890 192 0.27 Brass 10% zinc 1040 252 0.24 20% zinc 995 234 0.25 Iron 1538 451 0.18 Steel 1515 442 0.18 * at ratios less than 0.40 the plastic flow surrounding the hallmarks should be stable at temperatures up to the stress annealing temperature ** from Smith, 1978; all other melting point figures are from Lide, 2002; other figures were calculated

2.1.2 Anisotropy constants instead of the three required to A second consideration in imaging residual describe the cubic system. A typical test for deformation is to determine the acoustic isotropy (again within the cubic system) is properties of the subject material and any the Zener Anisotropy Ratio [C11 – C12] / possible anisotropy of the material. Unless 2.0 to C44 (Chung and Buessem, 1968). the deformation process produces micro- Clearly [1.239 – 0.939] / 2.0 = 0.150 and is fractures there is no reason to anticipate that not equal to 0.461 so silver possesses a truly isotropic material would be rendered considerable anisotropy. Therefore anisotropic by plastic deformation. ultrasonic backscatter from the silver grains Anisotropic materials, however, should should be able to track the modifications in undergo considerable change during the microstructure caused by the plastic flow deformation, since a local deformation in the silver around the hallmarks. would significantly rearrange that Anisotropy for other metals is shown in microstructure. It seemed appropriate to Table 3. Having established this possibility, estimate the anisotropy in silver to one should immediately state that determine if ultrasonic backscatter from the backscatter imaging of the silver silver microstructure itself might be used to microstructure has not proven effective to track the deformation underlying hallmarks. date for displaying residual deformation in The three elastic constants for single crystal the silver. The probable explanation for this silver (cubic system) are C11 = 1.239 Mbar, has to do with the small size of the silver C12 = 0.939 Mbar, and C44 = 0.461 Mbar grains since, even at 50 MHz, the grains are (Simmons and Wang, 1971). Isotropic too small to provide any backscatter materials have only two independent elastic amplitude.

8 Table 3. Estimation Of The Degree Of Anisotropy Of Various Metals RATIO OF [C11- METAL C11 C12 C44 C12]/2.0 TO C44* Gold 1.923 1.631 0.420 0.15 Silver 1.239 0.939 0.461 0.15 Copper 1.684 1.214 0.755 0.24 Lead 0.495 0.423 0.149 0.05 Brass-4% zinc 1.633 1.177 0.744 0.23 9% zinc 1.571 1.137 0.723 0.22 17% zinc 1.499 1.098 0.715 0.20 Iron 2.314 1.346 1.164 0.49 * If this ratio is less than C44 then the metal exhibits anisotropy. All data are from Simmons and Wang, 1971.

2.2 Coupling Fluid the metal. A search was made for a liquid with a relatively slow acoustic velocity For frequencies much above 1 MHz, transmission and that met certain health acoustic waves are rapidly attenuated in and safety considerations. A line of air so it is necessary to utilize a coupling perfluoro liquids called Fluorinert®, fluid between the transducer and object to manufactured by 3M Specialty Materials be imaged. The acoustic properties of the met the health and safety criteria and are coupling fluid are a significant factor in non-corrosive when in contact with determining the resolution that can be precious metals. They contain no achieved by the acoustic imaging system. hydrogen or chlorine making them un- The most widely used fluid is water but reactive to most metals and they are other fluids have acoustic properties environmentally safe, non-toxic, have a (namely a higher or lower velocity) that low volatility, and have an acoustic make them superior to water particularly transmission velocity of about one half when surface wave imaging is used (Table that of water. 4). After initial experimentation with various Distilled water at ambient room Fluorinert® liquids it was determined that temperature was initially used to produce FC-40 was best suited to the imaging back-wall acoustic images of the requirements. This coupling liquid had hallmarks. While this produced the least attenuation of the acoustic signal reasonable images it was felt that the while its acoustic properties best matched image resolution could be improved by the transducer lenses available at the time processing surface wave information from (Table 5).

9 Table 4. Relative Acoustic Velocities Of Some Coupling Fluids TEMPERATURE VELOCITY ABSORPTION COUPLING FLUID 2 (DEGREES C) (MM/µSEC) (S /M) Distilled Water 25 1.495 22.0 Distilled Water 60 1.550 10.2 Acetone 30 1.158 54.0 Ethanol 30 1.127 48.5 Methanol 30 1.088 30.2 FC-40 25 0.656 Not available

Table 5. Acoustic Properties Of Select Fluorinert® Liquids ACOUSTIC VELOCITY DENSITY VISCOSITY COUPLING LIQUID (MM/µSEC) (G/ML) (CENTISTOKES) FC-40 0.656 1.87 2.2 FC-70 0.687 1.93 14.0 FC-72 0.512 1.68 0.4 FC-77 0.505 1.78 0.8 FC-84 0.542 1.73 0.55 Distilled Water 1.495 1.00 1.0

The propagation of longitudinal sound Type V390 50 MHz F/2 transducer with 0.5” waves in water is approximately 1.48 focal length, 0.25” aperture opening, and a 1.5” mm/sec versus 0.656 mm/sec in the diameter quartz buffer-rod. For surface wave FC-40. This slower acoustic velocity imaging a Panametrics polymer film 20 MHz translates into a smaller angle of incidence F/1 transducer with 0.4” focal length and 0.4” for the generation of surface waves in aperture opening was used. These transducers silver allowing for the use of standard were already available at the facilities where all transducers for the imaging instead of imaging took place. requiring custom-made transducers if water was the coupling medium (Table 6). With the hopes that the resolution of the surface wave images could be further For this work FC-40 was used to make improved, a custom designed transducer was surface wave images in the sterling silver purchased. It was a Panametrics PZ25 33 objects discussed here. The images MHz PVDF film transducer with 0.25” focal acquired in this work were all made by length and 0.25” aperture opening. It was felt immersing the silver objects in FC-40 for that the shorter fluid path of this transducer surface wave imaging and in distilled would allow for higher frequency returns water for back-wall imaging. (improved resolution) but the frequency of the returned signals still did not exceed much more 2.3 Acoustic Transducers than 7.5MHz. This was only a slight improvement over the 20 MHz F/1 transducer After some initial testing it was determined that originally used and did not produce visually the best (highest resolution) images for back- superior images. wall imaging was obtained with a Panametrics

10 Table 6. Acoustic Velocities And Angle Of Incidence To Generate Surface Waves In Sterling Silver And Gold* STERLING CHARACTERISTIC 18K GOLD 22K WATER FC-40 SILVER Longitudinal 3.89 3.55 3.39 1.48 0.656 velocity (mm/sec) Shear velocity 1.73 1.46 1.31 0 0 (mm/sec) Rayleigh 1.63 1.33 1.15 Frequency Frequency velocity dependent dependent (mm/sec) Angle of Water FC-40 Water FC-40 Water FC-40 incidence to generate 65.3o 23.7o >90o 29o >90o 35o surface waves *All figures were experimentally derived

2.4 The Scanning Acoustic Microscope years so that the marks would be neither too deep nor too shallow. The struck surface of The microscope utilized for all the coupon was then polished with various experimentation is owned by General Electric grades of diamond paste on a Struers Research and Development and located in Prepamatic rotary lapping machine until the Schenectady, New York. The scanner is an hallmark was no longer visible; approximately Anorad ruling engine design. The electronics 0.3 mm of silver was removed. This was done were developed by General Electric and have a to approximate the slow removal of the silver bandwidth of 100 kHz to 100 MHz with 70 dB surface in much the same manner as years of of available gain. The dynamic range of this polishing. The polishing was done at the system is 40 dB and its output data is digitized premises of Honeywell Federal Manufacturing at 8-bits. The display software is called and Technologies in Kansas City, Missouri. Winview and was also developed by General Electric. Once the marks were completely removed from the surface, the coupon was placed in a 2.5 Initial Experimentation container with some keys and the container 2.5.1 Sterling Silver Coupons vibrated to produce scratches on the silver to simulate the surface on a genuine aged silver Initial experimentation was conducted on a object. The three ultrasonic images shown in blank sterling silver (92.5 % silver) coupon Figure 6 illustrate the detail ultrasonic imaging measuring approximately 25 mm x 25 mm x 3 can produce on both intact hallmarks and the mm. An experienced silversmith then placed deformation remaining after removal by three different hallmarks on one surface. A polishing. Figure 6a shows a 50 MHz F/2 silversmith was employed to produce the back wall image of a coupon that still retains hallmarks thinking that he would strike the almost all of the hallmarks placed on it as silver with approximately the same force used struck. Figure 6b shows a 50 MHz F/2 back- by silversmiths for the past several hundred wall image of the residual deformation in the coupon where almost all of the original

11 hallmarks have been polished away. Figure 6c In order to prove that this imaging technique shows a 20 MHz F/1 surface wave image of was not unique to the apparatus at General the same deformation as figure 6b except Electric, another research facility that employs viewed from the surface containing the residual acoustic microscopy, Honeywell Federal deformation. Both back-wall images were Manufacturing and Development in Kansas acquired using water to couple the ultrasonic City, Missouri, was asked to replicate the beam into the part. The surface wave image experimental procedure used on the test used FC-40 in order to mode convert a coupon. The images compared quite favorably longitudinal wave in the fluid into a surface to the images produced by General Electric so wave on the silver coupon’s surface. it is felt that the imaging procedure is applicable for use on other acoustic microscopes. See Plate No. 31.

Figure 6. Three ultrasonic images of a sterling silver test coupon. (a) A 50 MHz F/2 back- wall image of the original hallmark. (b) A 50 MHz F/2 back-wall image of the residual deformation remaining in the coupon after the hallmark has been polished away. (c) A 20 MHz F/1 surface wave image of the same deformation in 6b except imaged from the surface containing the deformation

12 2.5.2 Gold Coupons but surprisingly, either no images or barely perceptible images of the polished-off hallmarks Coupons of 18K and 22K gold, measuring were recovered (Figure 7). A possible approximately 25 mm x 25 mm x 3 mm, were explanation for these results can be accounted for purchased and stamped with hallmarks by an by one of the physical properties of gold- its experienced silversmith. These alloys were malleability. High purity gold is extremely chosen because the earliest historical European malleable and does not produce plastic flow standard for gold work was 19.2carats (80%). In when struck during the hallmarking process. later years additional standards were established Instead, the metal simply pushes aside and wells- but it was felt that 18K and 22K would represent up around the hallmark leaving no deformationto the alloys that would be most often encountered image. It is proposed that a lower purity gold, in works of art. such as 14K (58.3%), that has been alloyed with an increasing quantity of copper will exhibit some Once the hallmarks had been placed on the plastic deformation making it possible to recover coupons they were polished off as previously hallmarks using the acoustic imaging technique. described. Surface wave imaging of the gold No further experimentation with gold was done coupons was done only with FC-40 as the because of the lack of results on these two coupling medium; no back-wall imaging was coupons. done. Converted surface waves were captured

Figure 7. Acoustic images: (A) an 18K gold coupon and (B) a 22K gold coupon

13 2.6 Objects Scanned without meeting the generally accepted 92.5% silver content. In fact, there are examples of A total of twenty-nine silver objects were scanned American ‘sterling silver’ that contain no silver at (Table 7). Objects were selected to cover a broad all. In the end, these variations in the silver range of ages and to represent silverwork from content proved to have no effect on the ability to several countries. It was assumed that not all image the residual deformation in the silver. objects were “sterling” silver as alloy standards varied from country to country and changed Objects chosen for imaging were limited to a through the course of time. For example, the fairly small size for two considerations. First was English silver standard was changed from sterling the quantity of the coupling fluid available. After (92.5%) to Britannia (95%) for the period 1697- the coupling fluid, FC-40, was chosen only a 1719. However, the Britannia standard was small quantity, approximately two liters, was never abolished leaving the silversmith free to purchased due to the very high cost of the produce wares that were marked with the sterling material and for fear that it could quickly standard but could in fact be of the higher silver evaporate if there were no mechanism to prevent alloy. It should be remembered that the alloy it from doing so. Secondly, it was much more standards provided for minimum silver content difficult than initially thought to find silver but not a maximum silver content (Jackson, objects with worn-off hallmarks that the owners 1921). were willing to lend for the experiments. Insurance considerations prevented certain pieces Other countries established their own standards, from leaving the Nelson-Atkins Museum and which, again, varied over time. Imaging of private owners were hesitant to loan their silver to American silver objects was initially avoided, as the project without additional insurance. In the their silver content could not be verified without end, only five pieces from the Nelson-Atkins additional testing. Standards for American silver Museum were tested, with the rest coming from were not formally codified until 1906, which loans from silver dealers, private owners, or meant that silver could be called ‘sterling’ purchases.

14 Table 7. Objects Scanned For Hallmark Recovery Project

OBJECT DATE OWNER ORIGIN PLATE NO. Sterling silver test coupon Modern Purchased 1, 2 & 31 Sterling silver test coupon Modern Purchased Figure 12B (annealed) Teaspoon (Bateman) 1792 NAMA no. 72-45/4B English 3 Spoon (Christina) Early 20th C. Nelson American 4 c Teaspoon (salt) 1780 Purchased English 5 Teaspoon (Paul) Unknown P. Benson Unknown 6 Teaspoon (EW) 1790’s (?) Purchased English (?) 7 Teaspoon (MH) Unknown Purchased Unknown 8 Teaspoon (JRD) Unknown Purchased Unknown 9 Teaspoon (1 Mono) Unknown Purchased Unknown 10 Paten cover 1569 NAMA no. 52-16B English 11 Dessert knife 1800-1810 NAMA no. 76-34/12C French 12 Fish knife 1875-1925 NAMA no. F83-76/10 French 13 Spoon (Churchman) Unknown M. Churchman English 14 Fork (Belgium) 18th c. W. Wilkinson Belgium 15 Spoon (Apostle) 1603 J. Shredds English 16 Spoon (Apostle) 1603? J. Shredds English 17 Fork (Barbados) Colonial W. Wilkinson Barbados 18 Spoon (Rattail) 1716 J. Shredds English 19 U.S. Silver Dime 1840’s G. MacCurdy American 20 & 21 French coin 1790’s K. Garland French 22 Spoon (BH) 18th c J. Weidman Scottish 23 Spoon (George III) 1790 W. Wilkinson English 24 22K gold coupon Modern Purchased 25 18K gold coupon Modern Purchased 26 Nichols Silver Coupon A Modern Purchased 27 Nichols Silver Coupon B Modern Purchased 27 Trivet 1787 NAMA no. 71-45/1 English 28 Fork (Monogram) 1808 W. Wilkinson English 29 Spoon (1809) Unknown W. Wilkinson French 30 Caribbean

15 3.0 RESULTS legible on the other from this set, making it easier to target the desired image To eliminate duplicate discussions of the quality. In Figure 8a the makers’ initials are results of scanning all the individual objects, clear but much of the remaining hallmarks only a few of the results that illustrate a have been removed. Figure 8b shows particular point will be presented here. isolation, magnification, and partial recovery Acoustic images of all of the objects can be one of the hallmarks believed to be that of a found in the attached plates. lion. The image of the “lion” shown in Figure 8c is the best result of a series of 3.1 Sterling Silver Spoon Handle trials where the focus of the transducer was changed slightly for each trial. The Figure 8 shows a set of surface wave images importance of even very small changes in of a sterling silver spoon wrought by Peter the system focus has been repeatedly and Ann Bateman dating from 1792. This demonstrated in the course of this work. To teaspoon, one from a set of eight, was the untrained eye the figure of the lion is not chosen because its four hallmarks varied clear in the acoustic image but to an expert it from perfectly readable to completely is readily discernable (Wilkes, 2001). polished away. Also, the four hallmarks are

Figure 8. (a) Ultrasonic images of the handle of a sterling silver teaspoon wrought by Peter and Ann Bateman dating from 1792. (b) The initials of the makers are clear but much of the remaining hallmarks have been removed. (c) Shows the isolation, magnification, and partial recovery of a figure thought to be a lion.

16 Subsequent imaging processing comparisons another teaspoon from the same set. Again, with a visible hallmark from another there is near perfect registration of the teaspoon from this same set of spoons has recovered acoustic image on the visible confirmed that the recovered image of the hallmark. This demonstrates that the lion mark is identical to the visible hallmark. recovered hallmark image is actually the A series of six acoustic images of the worn- letter ‘r’ and that it was struck with the same off lion hallmark were adjusted for size and die as the visible hallmark on the other overlaid on top of a digital image of the teaspoon. visible lion hallmark. The acoustic images were made by adjusting the focal spot of the sound waves either a little higher or a little lower in the metal. With only a two hundred-nanosecond difference in the travel time of the sound waves from the first acoustic image to the sixth one there was a surprising difference in the quality of the images (200 nanosecond travel time converts to an actual distance difference of 0.0026 inch). The composite acoustic images had near perfect registration on the visible hallmark which demonstrates that the illegible hallmark was struck with the same die as the visible hallmark on the teaspoon from this set of teaspoons (Figure 9).

Figure 10. Recovered acoustic images of the date letter ‘r’ overlaying a digital image of a visible ‘r’ hallmark from the same set of teaspoons.

3.2 Sterling Silver Fish Knife Blade

Figure 11 is intended to show the lack of subsurface deformation where one would naturally assume that it should be present. Shown is a set of ultrasonic back-wall images of the sterling silver blade of a Figure 9. A recovered acoustic image of a worn-off French fish knife dated approximately 1875 lion hallmark overlaying a digital image of an to 1925. One hallmark has been isolated identical hallmark from the same set of teaspoons. and magnified (b) for comparison to the back-wall image of the deformation in the Figure 10 shows the best results of a series test coupon (c). Clearly no deformation of trials on recovering the date letter ‘r’. appears to extend from the fish knife Here, a series of three acoustic images of the hallmark, suggesting that it has either been letter ‘r’ were adjusted for size and improperly struck by the silversmith, it has orientation then overlain on top of a digital been worn away through the subsurface image of the corresponding hallmark from deformation zone, or the residual

17 deformation has been ‘relieved’ during an finished object would therefore have been annealing process. The annealing process subjected to multiple annealing steps during could have occurred during manufacture or its manufacture thereby relieving the metal that the heat from the process of soldering of any remnant deformation from the the handle to the blade was sufficient to hallmarking procedure (Bimbenet-Privat and cause a localized annealing of the hallmarks de Fontaines, 1995). This is in contrast to since they are placed quite close to the the English system of applying the attached handle. hallmarks only after the object had been completed or nearly completed, thus the A literature search found that three of the residual plastic deformation in the metal four hallmarks applied on French silver would be expected to be retained. An manufactured prior to 1789 were actually exception to this procedure will be discussed applied to the roughed–out silver sheet later. before the object was completed. The

Figure 11. Ultrasonic back-wall image of the sterling silver blade of a French fish knife dated approximately 1875 to 1925. One hallmark is isolated (b) and magnified for comparison to the back- wall image of the coupon (c). No deformation appears to extend from the fish knife hallmark.

18 To confirm the historical accounts of the 1789 French silver objects (after this date French hallmarking procedures a sterling the French hallmarking procedures were silver coupon was stamped with several changed). hallmarks as described earlier. Again, the marks were polished off and images of these By chance, Figure 11 also shows additional hallmarks were produced with the acoustic information recovered by acoustic imaging imaging technique. The coupon was then concerning the quality of the solder join of annealed in an oven at 700 ºC for twelve the handle to the blade. The light colored minutes and then subjected to the imaging spots inside the attachment area represent procedure. After only one annealing the gaps/flaws in the solder join. These areas remnant deformation has been ‘relaxed’ and have a different acoustic response than the the hallmarks can no longer be imaged surrounding well-soldered metal so they are (Figure 12). Incidentally, the dark area in readily visible. Figure 12 B shows an enrichment in copper compared to the lighter colored more silver Another interesting chance image was rich area around it. (See also the SEM-EDX obtained from a 16th century paten cover analysis on Plate 32) (not illustrated) during the course of imaging the hallmarks. In this case, flaws or bubbles Regrettably, this means that the acoustic in the coating that were not visually imaging technique will not work on pre- apparent but were quite obvious in the acoustic image.

Figure 12. Effects of annealing on sterling silver. (A) A recovered acoustic image of polished- off hallmarks on a sterling silver coupon before annealing. (B) The same area after annealing the coupon.

19 3.3 Dessert Knife This object serves as a reminder that inscriptions can be created by several means and only those Acoustic images of a steel bladed silver created by stamping the metal produce a French dessert knife dating from the subsurface deformation that can be recovered by beginning of the nineteenth century are acoustical imaging; the process of removing illustrated in Figure 13. The partially worn- metal does not create therequisite deformations. off maker’s name is ‘engraved’ on the steel blade and appears to be an ideal candidate 3.4 Apostle Spoon for the recovery of an engraving using the acoustic imaging method. The direct Figure 14 is an acoustic image of the hallmarks reflection image in (a) clearly shows the on a silver Apostle spoon supposedly dating from maker’s name with the central section 1503. The date letter “F” was visible and clearly completely worn away; Figure 13b is a readable but the other mark could not be surface wave image of the same area. No discerned. A series of acoustic images were made of the hallmarked area by focusing the sound at progressively deeper intervals into the metal. Unfortunately, none of the images were able to resolve the illegible mark but some unexpected information was gained. In Figure14 it can be seen that (1) there is a noticeable bulge in the handle where the hallmark has been applied and (2) there is a well defined join line just to the right of the letter “F” where it appears that the handle was either broken and repaired or that two individual handles have been joined to form one complete handle. In either case, the placement of the hallmarks is rather odd. It Figure 13. Silver dessert knife with a steel blade. should also be noted that this join and bulge are (a) Direct reflection acoustic image. (b) Surface not apparent in a visual inspection of the spoon. wave acoustic image of the same area. An experienced dealer was able to immediately remnant is seen in (b) because determine that the spoon was a forgery based on the maker’s name has not been applied to stylistic grounds while the acoustic image the blade by stamping but probably by provides hard evidence of the deceit. etching or through the mechanical removal of metal. In either case, there is no subsurface deformation so acoustical methods cannot recover the missing inscription.

20 Figure 14. Acoustic image of the hallmarks on a silver Apostle Spoon supposedly dating from 1503.

3.5 Monogram 1808 Silver Fork

Figure 15a is an acoustic image of a purposely-removed hallmark from an English fork by Thomas Barker dating from 1808. At some period during the spoon’s lifetime an owner decided to add the monogram ”M” to the back of the handle. In order to accommodate this addition, the lion hallmark was removed. Traditionally, there have been four ways of removing hallmarks and engravings. If the marks were shallow they could simply be polished away. Deeper marks could be hammered out with a subsequent thinning of the metal. They could also be filled with silver solder and finished to seamlessly blend with the surrounding metal. Finally, they could be filled by a process know as ‘stoning’. In this case the surface of the silver is literally Figure 15. Silver fork with a hallmark deliberately rubbed with a stone, pushing the removed. (A) Photograph of the visible hallmarks on the fork. (B) An acoustic image of the hallmarks surrounding metal into the indentations of showing that a fifth mark was present at one time. the hallmarks or engravings. Marks The now-missing hallmark has been interpreted as a removed by hammering and stoning cannot lion. be recovered by acoustic methods but marks erased by polishing and filling should be being the lion hallmark was based on a recoverable. In the case of the lion much clearer computer image at the time the hallmark, its recovery probably meant that image was acquired. the hallmark was simply polished away. Image processing using Adobe Photoshop Note that in the acoustic image presented CS was used to try to enhance the image of here, the hallmark is difficult to decipher. this recovered hallmark. Various filters At best it can only be recognized that there were applied to the original acoustic image was a hallmark present at some time in the to bring out any residual information that past (Figure 15b). The interpretation of this could be present in the acoustic image and it

21 is now possible to positively identify the 3.6 American Silver Dime hallmark as that of a lion, as was expected (Figure 16). One important application of the acoustic imaging technique involves the potential ability to image worn-off inscriptions on coins. Coins are commonly encountered on archaeological excavations and can provide critical assistance in dating and determining the history of the site.

Two coins, one copper alloy and the other one silver (Figure 17), were imaged to try and recover the date stamped on them. In neither case was this successful but different previously illegible markings on the coins were seen in the acoustic images. In this case, the ability to image the markings probably depended on whether or not there was a design on the opposite side in the corresponding position. Since both sides of the coins were struck at the same time there Figure 16. A. Original acoustic image of removed hallmark from the spoon in Figure 15a. B. Photo- is a mixing of the subsurface deformations enhanced image of the same hallmark indicating a that the acoustic signal could not resolve. worn image of a lion. C. Photograph of a lion Even though the dates of the coins could not hallmark for comparison with B. be directly ascertained, the images of the other markings were sufficient to allow an The use of photo-enhancement software expert to make an informed identification of greatly improved (in some cases) the quality both coins. of the acoustic images to the extent that positive identifications of images of worn- In the case of the dime illustrated in Figure off hallmarks could be made by non-experts. 17A the surface wave image reveals the Subsequently, all of the acoustic images word ‘one’ which is not visible in the direct acquired during the course of this reflection image Figure 17B. investigation were re-examined and these enhanced images are included in the Plates.

Figure 17. American silver dime dating from the 1840’s. (A) Surface wave acoustic image made in FC-40 as the coupling medium. (B) Same image except water was used as the coupling medium for the direct reflection image 22 3.7 “EW” English Teaspoon the previously unidentified teaspoon could now be identified as being made by Thomas The teaspoon had a partially readable Wallis (initials TW) and the date mark as the maker’s mark with the first initial being a letter “h” for the year 1783/84. The third “T”, the second initial too worn too be read, hallmark was not distinct but resembles the and two other illegible hallmarks present on mark for sterling quality metal; i.e. the lion the reverse of the handle (Figure 18). passant. (See Figure 20.)

Figure 20. Image processed acoustic image with the date letter “h” and the maker’s initials “TW” outlined for clarity. The third hallmark is still illegible but resembles the lion passant mark for sterling quality metal.

Figure 18. Photograph of a teaspoon with one 4. DISCUSSION partially readable hallmark and two illegible hallmarks. A total of twenty-nine silver, gold, and bronze objects from widely varying time The acoustic images revealed that the two periods have been subjected to the acoustic illegible hallmarks were probably the date imaging techniques. Objects imaged mark and the mark for sterling silver, a lion, included spoons, forks, knives, coins, a but both images lacked the resolution to paten cover, a trivet, and coupon blanks. make a definitive interpretation of the marks Results from the modern sterling silver (Figure 19). blanks have been very encouraging. The hallmarks were placed on the blanks in the early summer of 1997 by an experienced silversmith. These hallmarks were well and truly struck, i.e., their original existence is well documented. After the hallmarks were removed by polishing, ultrasonic imaging produced clearly decipherable images of the remnant deformation on the surface of the silver. Both surface wave imaging and back-wall imaging were clearly effective at Figure 19. Acoustic image of the ”EW” teaspoon displaying residual deformation in the silver. with illegible hallmarks and a partial hallmark. Where only part of the hallmark was removed, the imaging methods are able to Image processing using PhotoShop CS show remnant deformation extending out clarified the acoustic image to the extent that from the remnant surface dents in the

23 surface. The blanks are now approaching possibility is most unlikely as the theoretical seven years in age. Repeat images show stress annealing temperature of sterling results in 2002 that reproduce the results silver (193o C) is well above the boiling shown in the initial 1997 images. However, point of water. despite the clear anisotropy in silver, backscatter imaging of the silver One other scenario based on the hallmarking microstructure has not yet proven effective. procedure itself may also be possible. When Neither the silver microstructure itself nor a hallmark is applied to a thin piece of silver deformation of that microstructure has been a ‘witness mark’ may appear on the reverse shown by backscatter imaging at the 20 side of the silver from where the mark was MHz or 50 MHz frequencies used to date. struck. This witness mark is a raised area The failure of the backscatter imaging is with the same shape as the hallmark. If this confusing since both the back-surface mark is visible the silversmith may wish to reflection images and the surface wave remove it; this procedure is called ‘setting images clearly indicate that the acoustic back the hallmark’. The silversmith may properties of the silver showed significant simply hammer the witness marks flat or can changes at the hallmark locations. The apply localized heat to that area first to make small size of the silver grains may be one the hammering process easier and less likely factor in the inability to produce backscatter to cause any damage to the surrounding images. More work needs to be done to metal. In the case of flatware, the hallmarks fully understand this. were frequently applied to the back of the handles before they had been wrought to Work to recover partially obliterated their final shape. This allowed the assay hallmarks on antique silver objects has been office to place their marks completely on the less encouraging than the work on the silver and still allow the metalsmith the coupons. But in these cases one cannot be freedom to produce a slender handle that in certain that the hallmarks were properly the final shape would not provide sufficient struck in their original condition. The silver space for the hallmarks; the final shaping blade of the French fish knife (Figure11) would have certainly involved heating the demonstrates this case in point. The fish metal. This local annealing effect would knife is ideally configured for back-wall then diminish the ability to produce an imaging and yet no remnant deformation image of the hallmark using acoustic could be shown to extend from the dented methods. marks remaining on the blade. Several different scenarios could account for this. As mentioned earlier, it was not possible to First of all, the hallmark could have been experiment with silver objects of greater improperly struck so that the entire mark value than flatware due to insurance was never there in the first place. It is also restrictions. It is possible that objects that possible that the heat from the soldering are of a size that would allow for the attachment of the handle annealed the silver hallmarks to be fully struck without thus removing the residual deformation of alteration of the shape of the piece after the the hallmark. Use and/or polishing may marks have been applied would be more have partially removed the residual amenable to the imaging technique. For subsurface deformation or repeated washing example, the shape of a plate or vessel in boiling water over an extended period of would have been fully developed before the years partially annealed the silver. This last hallmarks were applied (except in France)

24 such that only a final cleaning would have produce an image. Unfortunately, there are been required to complete the piece and it is no visual clues on the surface of the metal not envisioned that cleaning, even in a hot that will permit speculation on the success acid bath to remove fire scale, would be or failure of the acoustic imaging technique. sufficient to remove the subsurface Each object will have to be imaged deformation of the hallmarking process. It individually to determine if there is any is quite regrettable that this could not have residual deformation to be found. been proven by experimentation on antique silver objects. Images of removed or worn-off engravings may be recoverable depending on their Surface wave images of two antique coins method of removal. The inscription would suggest that downward or compressive have to have been applied by chasing, i.e. by deformation, i.e., a dent, is more readily hammering the lines into the metal as defined than the up welling of material. opposed to removal of the metal with a Efforts to image the originally upraised scribe. Then they would have to be patterns of the years in which coins were ‘removed’ by either filling them with silver struck have not yet been successful. This solder or by being polished away. If the suggests that the deformation under dents is inscription was ‘removed’ by either more readily detected than bulges. Also, hammering or by stoning then the acoustic since both sides of a coin are struck at the method cannot be used for their recovery. same time there will be some mixing of subsurface deformations making it more Worn hallmarks on objects manufactured difficult to separate individual elements of from high purity gold cannot be imaged with the design, e.g., the date. the acoustic methods as described here. The historical standards for objects made of gold have been 18K or greater. It is suggested 5. CONCLUSIONS that at this purity gold is too malleable to produce plastic flow when struck in the The success rate for acoustic imaging of hallmarking process. As the quantity of worn-off hallmarks on the twenty-nine alloying metal in gold increases objects in this project has been (corresponding to a decrease in the purity of approximately ten per cent. While this the gold) the chances for the acoustic initially appears to be a fairly unsuccessful, recovery of worn hallmarks and inscriptions the project has succeeded in producing should increase but this has not yet been images one hundred per cent of the time proven experimentally. where remnant plastic deformation exists. Subsequent imaging processing of the Acoustic imaging of archaeological artifacts, images utilizing a standard software e.g. coins, has great potential to be a program further clarified about fifty percent valuable aid in dating and re-constructing of the acquired images. When the the history of excavated sites. The only deformation no longer exists either through caveat being that the objects must have a being poorly struck, being annealed out, or very smooth surface to permit successful completely worn/polished through the zone imaging. of deformation, acoustic methods cannot

25 6. ACKNOWLEDGEMENTS

This work described in this paper was The authors would like to thank Dr. Robert partially supported by a grant from the Organ, the Superintendent Assayer of The National Park Service and the National Worshipful Company of Goldsmiths, Center for Preservation Technology and London, for his contributions on Training. Its contents are solely the hallmarking technology; Marty Cunningham responsibility of the authors and do not at Honeywell Federal Manufacturing & necessarily represent the official position or Technologies, Kansas City for polishing the policies of the National Park Service or hallmarks off of the silver and gold coupons; National Center for Preservation Eric Jamieson also at Honeywell Federal Technology and Training. Manufacturing and Technologies for producing additional acoustic images; Dale A Coolidge Fellowship Grant from the Benson, Conservation Assistant and John General Electric Research and Development Lamberton, Digital Imaging Specialist at the Center to R. Gilmore supported part of Nelson-Atkins Museum of Art, for the Gilmore’s experimental research, and the image processing of the acoustic images, authors also thank GE for providing the Christina Nelson, former Curator of Center’s ultrasonic imaging facilities. Again, European and American Decorative Arts at the contents of this paper are solely the the Nelson-Atkins Museum of Art, for the responsibility of the authors and do not use of her silver collections and Wynyard necessarily represent any position or Wilkinson for the generous loan of silver policies of the General Electric Company. objects from his private business.

7. REFERENCES

Benson, P. L. 1991. Scanning acoustic Callister, W.D. Jr. 2003. Material Science th microscopy and potential application in and Engineering: An Introduction. 6 archaeological conservation. Unpublished edition. New York: John Wiley and Sons. dissertation in partial fulfillment of the requirements for the Degree in Dodd, E. C. 1961. Byzantine silver stamps. Conservation. Institute of Archaeology, Dunbarton Oaks Studies, 7: 23-35. University of London. Chung, D.H. and Buessem, W.R. 1968. The Bimbenet-Privat, M. and G. de Fontaines, elastic anisotropy of crystals. In 1995. La datation de l’orfèvrerie Anisotropy in Single-Crystal Refractory parisienne sous l’ancien régime: poinçons Compounds, Volume II. Ed. F.W. de jurande et poinçons de la marque 1507- Vahldiek and S.A. Mersol. New York: 1792. Paris: Paris Musées. Plenum Press.

Briggs, A. 1982. Acoustic Microscopy. Oxford: Oxford University Press.

26 Gilmore, R. 1999. Industrial ultrasonic Pickford, I., ed. 1989. Jackson’s silver and imaging/microscopy. Physical Acoustics, gold marks of ,Scotland & Volume XXIV, ed. E. Papadakis. New Ireland. 3rd edition. Woodbridge, Suffolk, York: Academic Press. 275-346. England: Antique Collector’s Club.

Hare, S. 1978. Touching Gold and Silver: Simmons, G. and Wang, H. 1971. Single 500 Years of Hallmarks. Catalogue of an Crystal Elastic Constants and Calculated exhibition at Goldsmith’s Hall, Foster Aggregate Properties: a Handbook. Lane, London EC2, November 7-30, 1978. Cambridge, MA: MIT Press. 85-86. London: Worshipful Company of Goldsmiths. Smith, E.A. 1978. Working in Precious Metals. London: N.A.G. Press Ltd. Jackson, C.J. 1921. English Goldsmiths and Their Marks. London: Macmillan and Co. Stavroudis, C. 1989. Possible applications Limited. of acoustic emission and scanning acoustic microscopy to the field of art Lemons, R. and Quate, C. 1979. Acoustic conservation: phase I- preliminary report Microscopy. In Physical Acoustics, - final draft. Malibu, California: Getty Volume XIV. ed. W.P. Thurston and R.N. Conservation Institute. 43-61. Thurston. New York: Academic Press. 1- 92. Treptow, R.S. 1978. Handbook of Methods for the Restoration of Obliterated Serial Lide, D.R. 2002. Handbook of Chemistry Numbers. NSAS Contractor report CR- and Physics. 83rd edition. Boca Raton, 135322. Cleveland, Ohio: NASA. Florida: CRC Press LLC. Wilkes, W. 2001. Personal communication. Ouahman, R. et al. 1995. Application de la Wynyard R.T. Wilkes F.S.A. Scot, Silver microscopie acoustique à l’étude des Merchant, 165-169 Portobello Road, produits de corrosion du fer London W11 2DY England. archéologique. In Metal 95: Proceedings of the International Conference on Metals Wyler, S.B. 1937. The Book of Old Silver, Conservation, Semur en Auxois, France, English, American, Foreign: with all September 25-28, 1995. 50-54. Available Hallmarks, Including Sheffield Plate Marks. New York: Crown.

27