Copyrighted Material

Total Page:16

File Type:pdf, Size:1020Kb

Copyrighted Material R2,55 radiation, 150 2 RAdj,55 Bomb calorimeter, 375 β, diameter ratio, 319 Bourdon gauge, 253 γ,ratio of specific heats, 326 bridge full, 259, 264, 435 acceleration, 436 half, 259, 260 accelerometer, 441 quarter, 259 Fiber Optic , 448 burst signal, 308 Piezoelectric, 445 accuracy, 6, 44 calibration, 5, 6 acousto-optic cell, 413 Callendar correction, 132 aliases, 80 calorific value, 360, 374 Alphatron gauge, 279 calorimetric method, 360, 370, 404 amplifier capacitance type pressure transducer, differential, 471 266 differentiating, 472 capture efficiency, 424 instrumentation, 474 Chauvenet’s criterion, 32 integrating, 472 Chemiluminescence, 418 logarithmic, 473 Chi Squared test, 62 summing, 470 circular frequency, 438 analog to digital converter (ADC), 480, coefficient of thermal expansion, 166 488 cold junction, 113 angular velocity, 448 Collis and Williams correlation, 296 APD, 417 compensated probe, 184 compressibility, 286, 326 beat frequency, 447 COPYRIGHTEDconduction MATERIAL error, 184 Beer’s law, 416 confidence interval, 9 bell prover, 340 confounded, 81 Bernoulli principle, 283 constant head tank, 381 best estimate, 8 continuous flow calorimeter, 378 Betz manometer, 467 correlation bias, 6 index of, 55 bit, 480 correlation black body coefficient, 54 cavity, 151 517 518 INDEX count, 480 total, 158 covariance, 50 entropy, 112 critical value, 64 equilibrium, 104 cross section error estimator, 15 absorption, 416 error propagation, 42 extinction, 416, 426 errors, 6 total, 417 random, 6 cubical expansion, 163 systematic, 6 cumulative probability, 9 Euler number, 83 current loop, 482 EXCEL, 494 Exhaust gas, 410 damping coefficient, 438 expansion factor, 326 critical, 438 damping ratio, 251, 440 factorial dead weight tester, 254, 435 2k,75 degrees of freedom, 15, 17, 65 fractional, 79 derived quantity, 4, 40 full, 74 Design of experiments, 74 one half, 79 DIAL, 415 quarter, 81 dial gauge, 434 factors, 74 diaphragm/bellows gauge, 262 film coefficient, 224 differential absorption, 416 filter, 476 diffuse, 391 high pass, 477 digit, 481 low pass, 477 digital data logger, 479, 488 neutral density, 155 digital panel meter (DPM), 480 notch, 476 digital voltmeter, 480 red, 154 dimensional analysis, 74, 82 twin T, 476 dimensionless, 83 fin analysis, 188, 192 dimensionless groups, 74 first order system, 173 Dixon’s Q test, 39 fit, 49 dominant factor, 78 fixed point Doppler primary, 107 effect, 303 secondary, 108 shift, 303, 447 flow coefficient, 318 velocimeter, 303 flow meter Laser, 307 calibration, 337 ultrasonic, 304 drag effect, 330 drag coefficient, 331 positive displacement type, 334 drop resistor, 482 turbine, 335 dual thin film probe, 345 variable area, 316 dynamometer, 448 discharge coefficient, 318 brake drum, 449 flow nozzle, 323 Electric generator, 449 irrecoverable pressure loss, 324 orifice plate, 319 electrical analog, 173 pressure taps, 319 emissivity, 157, 214, 225, 390, 400 selection, 330 hemispherical, 391 venturi, 323 spectral, 151, 153 variable area type, 346 INDEX 519 vortex shedding type, 334 ice point, 106 Flue gas, 410 ideal gas scale, 107 fluid velocity, 282 impact probe, 288 flying start - flying finish, 340 influence coefficient, 74 force balancing element, 273 integrating radiometer, 400 force measurement, 430 integrating sphere, 394 Fourier number, 369 interaction effect, 75 full bridge, 492 interpolation, 115 intrusive, 4 Gardon gauge, 205 ionization gauge, 278 sensitivity, 207 ITS90, 108 gauge constant, 207 time constant, 211 Joule heating, 110 transient analysis, 210 Gas Chromatography, 419 Kelvin relations, 110, 112, 113 gas concentration, 409 Kelvin sensing, 135 gas thermometer, 105 King’s law, 294 gauge factor, 256 Kirchoff’s law, 470 Gaussian distribution, 8, 10 Kolmogorov Smirnov two sample test, global polynomial, 115 29 gold point, 149 goodness of fit, 54 LABVIEW, 494 Graphic User Interface (GUI), 490 laminar flow, 380 Grashof number, 364 Laser Doppler Vibrometer, 446 LDV, 307 heat capacity, 360, 370 fringe system, 307 liquid, 373 reference beam system, 308 solid, 370 lead wire model, 186 heat diffusion, 110 lead wires, 118 heat flux, 205 compensating, 119 heat flux sensor least square method, 401 axial conduction guarded, 214 least squares, 11 slug type, 215, 218 levels, 74 thin film, 212, 220 Line reversal technique, 161 construction detail, 222 low pass filter, 306 thin wafer, 213 LVDT, 263, 266 heat transfer coefficient, 138, 223 convection, 172 Mach number, 282 cylindrical probe, 225 main effects, 76 radiation, 200 manometer heating value (HV), 379 U - tube, 245 high frequency transmitter, 493 well type, 247 high vacuum, 275 inclined tube, 247 Hooke’s law, 433 mass flow rate, 316 hot wire anemometer, 293 MATLAB, 494 constant current, 297 McLeod gauge, 276 constant temperature, 295 mean, 8 hypotheses, 4 measurements, 4 monochromator, 393 520 INDEX multi-hole probe, 291 pyrometer five hole, 292 total radiation, 157 three hole, 291 two color, 159 vanishing filament, 153 natural frequency, 438 pyrometer equation NDIR, 413 ideal, 153 Newtonian fluid, 380 practical, 153 non-intrusive, 5 pyrometry, 149 non-linear fit, 60 normal distribution, 8 QtiPlot, 67 normal equations, 50 NTC thermistors, 140 radiation error, 194 radiation shield, 196 opacity, 426 Rayleigh number, 176 operational amplifier, 469 recovery factor, 344 optical RPM meter, 453 reentry, 209 Orsat gas analyzer, 422 reference orthogonal set, 79 ice point, 119 outliers, 32 reflectance, 425 reflectivity parity plot, 59 bidirectional, 391 partial pressure, 410 directional hemispherical, 391, 399 phase lag, 181 hemispherical directional, 393, 398 Pierce’s criterion, 35 regression Pirani gauge, 277 linear, 49 Pitot static tube, 284 multiple linear, 57 Pitot tube, 282, 347 polynomial, 54 Planck distribution, 150 simple model, 76 platform balance, 430 repeatability, 74 Platinum 67, 121 repeatable, 6 Platinum resistance temperature scale, replicate, 74 132 resistance Poisson ratio, 256, 263, 493 flow, 250, 271 portable emissometer, 406 specific, 255, 256 Prandtl number, 177 thermal, 173, 270 Prandtl tube, 284 Resistance thermometer, 131 pre-amplifier, 493 Platinum, 131 precise, 6 resolution, 44, 81, 480 pressure response dynamic, 283 dynamic, 249 stagnation, 282 flat, 157 static, 283 linear, 6 pressure coeffcient, 293 non-linear, 6, 140 pressure transients, 269 periodic input, 179 primary quantity, 4 ramp input, 178 principal stresses, 450 steady state, 178, 181 Prony brake, 449 step input, 173 Propagation of errors, 40 transient, 178, 181, 249 proving ring, 435 Reynolds number, 55, 83, 199 INDEX 521 Rotameter, 330 subsonic flow, 286 analysis, 330 supersonic flow, 288 rotating cylinder viscometer, 380, 384 RTD, 131, 346 Tachometer, 453 Bridge circuit, 135 temperature dissipation constant, 138 actual, 152 four wire, 132 brightness, 152 lead wire compensation, 135 bulk mean, 346 measurement circuits, 135 color, 159 self heating, 138 inside a solid, 184 temperature coefficient of resis- mixing cup, 347 tance, 132 moving fluid, 185, 194 three wire, 132 solid, 191 stagnation , 344 sampling, 423 surface, 183 iso-kinetic, 424 systematic error, 183 Saybolt viscometer, 380, 383 transient, 171 search method, 60 true, 160 Conjugate Gradient, 60 Test for normality, 19 Levenberg-Marquardt, 60 χ2 test, 26 steepest descent, 60 Box and whisker plot, 20 second order system, 251 Jarque-Bera test, 24 Segmented or piecewise regression, 68 Q-Q plot, 22 shear modulus, 432 thermal conductivity, 360 shear stress, 450 comparator, 360, 367 shielded thermocouple, 344 Gaurded hot plate signal conditioning, 492 solid sample, 361 electronic, 468 Guarded hot plate, 360 mechanical, 466 liquid sample, 364 single wire model, 187 Laser flash method, 360, 369 slip rings, 493 Radial heat conduction appara- soap film burette, 337 tus, 360, 364 software, 494 thermistor solar flux, 209 circuit, 145 sonic nozzle, 328 thermistors, 140 soot, 423 thermo-electricity spectroscope, 162 Peltier effect, 110 specular, 390 Seebeck effect, 110 spring balance, 432 Thomson effect, 110 spring constant, 432 thermo-physical properties, 360 SRM, 368 thermocouple standard error, 19 bayonet probe, 127 Stefan Boltzmann constant, 158, 195 differential, 128 Steinhart-Hart equation, 141 junctions, 126 Stokes number, 424 butt welding, 127 Stolz equation, 319 button, 127 strain gauge, 255 exposed, 126 Strouhal number, 335 grounded, 126 Student t distribution, 17 separated wire, 126 522 INDEX parallel, 129 types, 122 thermocouples series, 128 thermoelectric power, 121 thermometer bimetallic, 166 IC temperature sensor, 171 liquid crystal, 170 liquid in glass, 163 thermometer error, 189 thermometer well, 185, 199 thermometric error, 127, 189, 192, 199, 201 thermometric property, 105, 107 thermometry, 104 thermopile, 128, 129, 212 thermostat, 170 Thompson τ test, 38 time constant, 173 time of flight, 282 TOF, 282 velocimeter, 309 torque, 448 transmittance, 426 trend line option, 64 triple point of water, 106 USB port, 488 vacuum, 275 variance, 8 velocimeter cross correlation, 313 velocity of approach factor, 318 vena contracta, 323 viscosity, 360, 380 voltage gain, 470 volume flow rate, 316 wedge probe, 289 Wein’s approximation, 150 displacement law, 151 Young’s modulus, 166, 169, 263, 433, 493 zeroth law of thermodynamics, 104 Zhukaskas correlation, 199, 294.
Recommended publications
  • BROOKFIELD DIAL READING VISCOMETER with Electronic Drive
    BROOKFIELD DIAL READING VISCOMETER with Electronic Drive Operating Instructions Manual No. M00-151-I0614 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY with offices in : Boston • Chicago • London • Stuttgart • Guangzhou BROOKFIELD ENGINEERING LABORATORIES, INC. 11 Commerce Boulevard, Middleboro, MA 02346 USA TEL 508-946-6200 or 800-628-8139 (USA excluding MA) FAX 508-946-6262 INTERNET http://www.brookfieldengineering.com TABLE OF CONTENTS I. INTRODUCTION .....................................................................................5 I.1 Components .......................................................................................................5 I.2 Utilities ................................................................................................................6 I.3 Specifications .....................................................................................................6 I.4 Set-Up ................................................................................................................7 I.5 IQ, OQ, PQ .........................................................................................................7 I.6 Safety Symbols and Precautions .......................................................................8 I.7 Cleaning .............................................................................................................8 II. GETTING STARTED ..............................................................................9 II.1 Operation ...........................................................................................................9
    [Show full text]
  • HAAKE Viscometer Standard Operating Procedure [Updated Sept 10, 2014]
    HAAKE Viscometer Standard Operating Procedure [Updated Sept 10, 2014] HAAKE Viscometer 7 R+ Location of Machine: Composites Lab, RFM 1218 Location of SOP and Machine Operating & Safety Manual: Composites Lab website under resources; Composites Lab TRACS site; and Hardcopy near machine. Emergency Contact: Call 911 Call EHS & Risk Management at 512-245-3616 Call Head Lab Technician, Dr. Ray Cook (office 512-245-2050) Call Dr. Jitendra S Tate (office 512-245-4872) Before using this machine: You must have permission from Dr. Tate. You must have received formal training from technician or, trained research student (designated by Dr. Tate) related to machine safety and operation. You must read and understand SOP and Machine Cleaning Manual. You must use this machine under direct supervision of Dr. Tate or, Dr. Cook or, trained research student (designated by Dr. Tate). You must have signed “Lab Rules” document with Dr. Tate. This document must be signed every semester fall, spring, and summer (as applicable). If you do NOT follow above instructions you will be held responsible for your own safety and damages. Safety Precautions: Protective Equipment: Prior to performing this procedure, the following personal protective equipment must be obtained and ready for use: Gloves, Safety Goggles, Face Mask, Lab Coat. Important Safeguards: 1. Prior to performing this procedure, the following safety equipment must be accessible and ready for use: (e.g. chemical fume hood, biological safety cabinet, laminar flow hood, chemical spill kits) Fume hood 2. All liquids should be drained to containers for chemical disposal and properly marked. 3. In the event that a hazardous material spill during this procedure, be prepared to clean with cleaner according to MSDS of materials used.
    [Show full text]
  • Building and Validating a Rotational Viscometer Brian Cherrington & Jack Rothstein Mechanical Engineering Faculty Mentors: Dr
    Building and Validating a Rotational Viscometer Brian Cherrington & Jack Rothstein Mechanical Engineering Faculty Mentors: Dr. Maria-Isabel Carnasciali, Dr. Samuel Daniels Abstract This project was an effort to redesign an initial prototype rotational viscometer to experimentally test whether or not viscosity values vary significantly when the geometry of the viscometer is changed. The scope of the project involved designing and building a viscometer that could vary the gap between the inner and outer cylinders, variation of the testing fluid’s temperature, and control of the device’s RPM. After weeks of planning, designing, and fabrication the new viscometer was complete. In order to control the device, monitor the sensor readings, and calculate the testing fluid’s viscosity a LabVIEW program was created. Testing on medium to high viscous fluids was completed to determine if the viscosity values and the geometry of the viscometer are dependent or independent of each other. The results did show a correlation between measured viscosity and variations in the geometry of the viscometer. More testing is required to further verify the results and properly calibrate the device. Introduction For this project a new design was conceptualized, fabricated, and tested. This new design met several criteria including, Viscosity is often referred to as a fluid’s thickness or how much it resists deformation due to an applied force. Designed for future use in ME labs; Rotational viscometers measure the amount of torque needed Designed to be durable, sustainable, and easy to to rotate an object moving through fluid at a known RPM. dissemble and clean; Using the measured torque, RPM, and dimensions of the Multiple inner cylinders for varying gap sizes; device, the viscosity can be calculated using equation 1.
    [Show full text]
  • Miniav®-X Automatic Viscometer Instruction & Operation Manual
    MiniAV®-X Automatic Viscometer Instruction & Operation Manual 81.2254 i CONTENTS 1 INTRODUCTION/INSTALLATION 1 The miniAV®-X Automatic Viscometer .................................................................................. 1 Measuring kinematic viscosity ............................................................................................... 2 Safety cautions ..................................................................................................................... 2 Specifications ....................................................................................................................... 4 Installation ............................................................................................................................ 4 Required installation components ............................................................................... 4 Vacuum Pump unit connections ................................................................................. 6 Bath unit connections ................................................................................................ 6 VISCPRO® for Windows® XP® ............................................................................................ 6 Installing VISCPRO® software .............................................................................................. 7 Computer requirements ............................................................................................. 7 Windows® XP® installation .......................................................................................
    [Show full text]
  • List of Equipments in the Department (Chemical Engineering) Mechanical
    List of Equipments in the Department (Chemical Engineering) Mechanical Operation lab Fluid Mechanics Lab Heat transfer Lab Mass Transfer lab • Cyclone Separator • Reynold’s Apparatus • Double Pipe Heat Exchanger • Tray Dryer • Plate & Frame Filter Press • Bernoulli’s Theorem Apparatus • Shell & Tube Heat Exchanger • Sieve Plate Distillation Column • Vibrating Screen • Pitot Tube Apparatus • Vertical Condenser • Liquid-Liquid Extraction • Jaw Crusher • Calibration of Orifice meter, • Computerized Control Shell & • Adsorption of CO 2 • Ball Mill Venturi meter and Rota meter Tube Heat Exchanger • Steam Distillation • Roll Crusher • Coefficient of Discharge of • Thermal Conductivity of Metal • Bubble Cap Distillation Column • Rotary Vacuum filter Orifice and Mouthpiece Bar • Cooling Tower • Fluidized Bed • Film & Drop Wise Condensation • Diffusivity Apparatus • Single Effect Evaporator • Fluidized Bed Dryer • Simple Steam Distillation • Simple Distillation • VLE Apparatus • Equilibrium Flash Distillation • Humidification & Dehumidification • Refractometer Process Control Lab Chemical Reaction Engg. Lab Fuel Combustion Energy Technology Lab Environmental Lab • Process Training Simulator with • Plug Flow Reactor • Flash & Fire Point Apparatus • BOD Incubator Modules (Software) • Isothermal Batch Reactor • Aniline Point Apparatus • pH Meter • Pressure Control System • Single Tube Packed Bed Reactor • Orsat Gas Analysis Apparatus • Sedimentation Apparatus • Flow Control System • RTD in CSTR / Mixed flow • Redwood Viscometer • UV-VIS Spectrophotometer • pH control System Reactor • Bomb Calorimeter • DO Meter • Real Time Simulator Trainer • RTD in Tubular Reactor • Smoke Point Apparatus • Digital Conductivity Meter • Level Control System • Adiabatic Batch Reactor • Temperature Control System • Distillation Column • Two Tank Interacting system • Two Tank Non-Interacting System • CSTR Control System Research Equipments • UV-Spectrophotometer • Gas Chomatography .
    [Show full text]
  • Department of Chemical Engineering
    DISTILLATION FLASK : Made of borosilicate glass is specified dimension. Capacity: 125 ml. GRADUATED RECEIVER: Capacity : 100 ml. sub-division 1 ml. the cylinder is made of heat resistance borosilicate glass. FLASK SUPPORT ASSEMBLY BOARD: Three asbestos board on each with centre hole 32 mm, 37.5 mm and 50 mm. are provided. TEMPERATURE CONTROLLER: By solid state variable heat controller. Complete Apparatus as described above but supplied with 3 Nos. flask support boards and glassware for operation on 220/230 V, 1ph, 50 c/s, A.C. mains. SPARES FOR ABOVE DISTILLATION APPARATUS: 1. Distillation Flask, borosilicate glass, Capacity : 125 ml. packet of 2(two) pieces. 2. Receiver, 100 ml. packet of 2(two) pieces . 3. Thermometer : Mercury-in-Glass, with NABL Certificate IP – 5C, packet of two pieces.; IP – 6C, packet of two pieces; ASTM – 7C, packet of two pieces. ASTM – 8C, packet of two pieces. 4. Heating Element, packet of two pieces. …………….. 5. Flask support plate, packet of one each (Total 3 nos.) 32 mm. Centre Hole; 37.5 mm. Centre Hole; 50 mm. Centre Hole 2. FLASH POINT PENSKY MARTENS (CLOSED) CONFORMS TO : IS: 1448 & 1209 – 58, IP: 34, ASTM: D-93 SPECIAL FEATURES: Cup & Cover with ebonite handle for operating at high Temperature. For determining the flash point of petroleum products having a flash point above 120º C (48.89º F). The instrument which will give trouble free service under continuous operating conditions. The cast iron air bath is fitted with heaters for uniform heating. An enclosed safety type heater made of nichrome heating element. Temperature is controlled by Digital Temperature Indicator cum controller which ensure smooth and easy control of the temperature.
    [Show full text]
  • Physical Quantity Measured by a Vibration Viscometer (Re: JCSS Standardization of Viscosity)
    Article for the 23rd Sensing Forum Theme: Physical Quantity Measured by a Vibration Viscometer (Re: JCSS Standardization of Viscosity) Presented by: Naoto Izumo R&D Division, A&D Company, Limited October 2 ~ 3, 2006 Tsukuba Center Inc. Tsukuba, JAPAN Physical Quantity Measured by a Vibration Viscometer Subtitle: The JCSS Standardization of Viscosity Naoto Izumo R&D Division, A&D Co., Ltd. Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 Japan Abstract The objective of this article is to introduce a viscometer that utilizes a new viscosimetry measuring method. In addition, the article will recommend a new unit system, which is utilized in the vibration viscometer. Using examples, the article explains JCSS viscosity standardization and recent requirements for viscosity measurements. Keywords: Vibration Viscometer, Static Viscosity (Viscosity × Density), Viscosity JCSS, Cloud Point Introduction The following is an introduction of the vibration viscometer, a new method for measuring viscosity. In addition to providing a description of the physical quantity that is measured using the vibration viscometer, a new unit system for viscosity will be proposed. Furthermore, there is an explanation regarding the Japan Calibration Service System (JCSS) standardization of viscosity and viscosity measurements using actual examples. There is also discussion of recent requirements for measuring viscosity. History and Development of Viscosity Measurement The history of viscosity measurements is extensive and is believed to date back to when people began measuring the viscosities of engine oils with the advent of the automobile industry in the United States. In the U.S., it had become necessary to control the viscosities of engine oils as a method of maintaining the performance of engines.
    [Show full text]
  • QCM Viscometer for Bioremediation and Microbial Activity Monitoring Wesley A
    304 IEEE SENSORS JOURNAL, VOL. 3, NO. 3, JUNE 2003 QCM Viscometer for Bioremediation and Microbial Activity Monitoring Wesley A. Gee, Member, IEEE, Kirsti M. Ritalahti, William D. Hunt, and Frank E. Löffler Abstract—A quartz crystal microbalance has been used to parameter eliminates the necessity of complex data interpreta- monitor the polymer production of a bacterial population in tion of samples by trained technicians. liquid medium. The increasing amount of produced polymer The aim of this study was to show that the QCM is a unique corresponds to an increase in the viscosity of the liquid, which is directly measurable as the fluid contacts the surface of the quartz and effective method to monitor a biological growth process to crystal in the sensor system. This procedure is being developed as aid in characterizing unknown bacterial populations. As a vis- a novel method for measuring microbial polymer production and cometer, this high shear rate device could be used in conjunc- growth of an environmental isolate obtained from river sediment tion with low shear rate laboratory viscosity measurement tech- contaminated with petroleum hydrocarbons. This measurement niques that currently include mechanical (rotational), capillary, technique may be used to monitor growth characteristics of unknown anaerobic bacteria when used in conjunction with falling ball, and other gravity or positive displacement methods. other currently employed microbiological test methods, such as spectrophotometry, to measure turbidity. II. DESCRIPTION OF BACTERIAL STRAIN In the presence of glucose, a novel, strictly anaerobic bacterial isolate, designated strain JEL-1, produces a viscous, as yet uniden- An unusual bacterial population, designated strain JEL-1, tified, polymer.
    [Show full text]
  • LABORATORY Viscometers
    LABORATORY VISCOMETERS www.irmeco.de Viscometer Cannon-Fenske Routine Cannon-Fenske Routine Viscometer according to ASTM D445-446, ASTM D2515, ISO 3104-3105 used for quick and easy measurement of the viscosities of trans- parent Newtonian liquids. Constant value (K) indication at +40°C and +100°C. Made of borosilicate glass, and non-alterable timing marks. Size Nominal Kinematic Art. No. No. viscometer constant viscosity range (mm2/s)/s mm2/s 25 0.002 0.5 to 2 10 15 81025 50 0.004 0.8 to 4 10 15 81050 75 0.008 1.6 to 8 10 15 81075 100 0.015 3 to 15 10 15 81100 150 0.035 7 to 35 10 15 81150 200 0.1 20 to 100 10 15 81200 300 0.25 50 to 250 10 15 81300 350 0.5 100 to 500 10 15 81350 400 1.2 240 to 1200 10 15 81400 450 2.5 500 to 2500 10 15 81450 500 8 1600 to 8000 10 15 81500 600 20 4000 to 20000 10 15 81600 All IRMECO® capillary viscometers are supplied with a Works Calibration Certificate issued in accordance with the conditions of accreditation granted by a National Metrological Register. 2 Viscometer Cannon-Fenske Routine Cannon-Fenske Opaque Cannon-Fenske Opaque Viscometer (reverse flow) according to ASTM D445-446, ASTM D2515, ISO 3104-3105 used for dark Newtonian liquids; especially suitable for liquids so dark in colour that cannot be seen in a Cannon-Fenske routine viscometer. It is also used to study shearing stress and shearing rate.
    [Show full text]
  • Brookfield Digital Viscometer
    BROOKFIELD DIGITAL VISCOMETER MODELDV-1+ Operating Instructions Manual No. M/92-021-A-892 BROOKFIELD ENGINEERING LABORATORIES, INC. 240 Cushing Street, Stoughton, MA 02072 USA Phone: 617-344-4310/4313 800-628-8139 (U.S. except MA); Fax: 617-344-7141 Telex: 924497 BRENLAB STOU (Western Union); 200195 BEL (RCA) TABLE OF CONTENTS L J:N'TRODUCfiON ......................................................................... 3 1 Com:p<>nents ............................................................................ 3 2 Utilities ................................................................................... 4 3 Specifications ......................................................................... 4 4 Set-Up ............................. ;....................................................... 4 S Key Functions ........................................................................ 5 ll. GETTJ:N'G STARTED .................................................................. 6 1 Autozero ................................................................................. 6 2 Spindle Selection .................................................................... 6 3 Speed Selection & Setting ...................................................... 7 4 Autorange Operation .............................................................. 9 S Out of Range Operation ....................................................... 10 Appendix A Cone/Plate Viscometer Set-Up .................................. 11 Appendix B - Viscosity Ranges .......................................................
    [Show full text]
  • Protocol: Measuring Viscosity of Cosmetics with Microvisctm
    Protocol: Measuring Viscosity of Cosmetics with microVISCTM Key Words: Face lotion, hand lotion, cream, viscosity, shear thinning, cleaning, high shear, non-Newtonian fluid, protocol, thixotropy Goal: Cosmetic lotions are often non-Newtonian fluids with yield stresses and thixotropic structure. These properties are vital for their function as selfcare products, but also make their rheological properties difficult to characterize. In particular, data collection can be time consuming and instrument cleaning can be challenging. This application note will share an easy-to-implement protocol to precisely measure complex cosmetic formulations using VROC technology. Introduction Skin care is an important part of personal healthcare. The epidermis is one of the body’s largest organs and is the first line of defense against pathogens, so maintaining and promoting healthy skin is vital for healthy life. Skincare products, specifically lotions, have been used for decades to promote skin health. When developing these products, manufacturers must carefully choose ingredients that must meet both consumer tastes and regulatory standards. These constraints make it vital to characterize lotion formulations, but also these criteria make consistent and fast measurements more challenging. Lotions are comprised of multiple materials including polymers, oils, waxes, gels, and silicones (Sharma et al. 2018). These ingredients can dramatically alter the viscosity of the lotion, but also make measuring viscosity difficult, messy, and variable. The combination of these ingredients can even cause lotions to behave as thixotropic materials. Thixotropy is the time dependent shear thinning property of non-Newtonian fluids (Mewis 1979). Thixotropic materials will slowly return to their high viscosity state once shearing has ceased.
    [Show full text]
  • Visco Handbook THEORY and APPLICATION of VISCOMETRY with GLASS CAPILLARY VISCOMETERS Welcome to SI Analytics!
    Visco handbook THEORY AND APPLICATION OF VISCOMETRY WITH GLASS CAPILLARY VISCOMETERS Welcome to SI Analytics! We express our core competence, namely the production of analytical instruments, with our company name SI Analytics. SI also stands for the main products of our company: sensors and instruments. As part of the history of SCHOTT® AG, SI Analytics has nearly 80 years experience in glass technology and in the development of analytical equipment. As always, our products are manufactured in Mainz with a high level of innovation and quality. Our electrodes, titrators and capillary viscometers will continue to be the right tools in any location where expertise in analytical measurement technology is required. In 2011 SI Analytics became part of the listed company Xylem Inc., headquartered in Rye Brook / N.Y., USA. Xylem is a leading international provider of water solutions. We are pleased to introduce you to the Visco Handbook! It replaces the previous brochure "Theory and Practice of Capillary Viscometry". This has been updated, redesigned and restructured. The information content of some areas such as polymer analysis was increased and specially themed areas such as hydrodynamic principles were moved into their own appendices so as not to deter the reader by too much theory. The focus was placed on the practical and general information needed by each user of capillary viscometry. Both laboratory experiences and policies of the relevant standards are considered here. We thus hope to provide you with a faithful companion for everyday laboratory work, one that you can use profitably. We of SI Analytics are pleased to work with you successfully in the future.
    [Show full text]