POMPY TŁOCZKOWE DLA OBIEGU OTWARTEGO Eaton PVQ - pompy tłoczkowe o zmiennej wydajności Table of Contents

Introduction...... 3 PVQ10 and PVQ13 Model Number System ...... 4 Controls (Compensators) ...... 6 Performance Curves ...... 7 Operating Data ...... 9 Installation Dimensions ...... 10 Shaft Options ...... 11 Controls ...... 13

PVQ20 and PVQ32 Model Number System ...... 16 Controls (Compensators) ...... 18 Performance Curves ...... 19 Operating Data ...... 19 Shaft Torque Data ...... 21 Installation Dimensions ...... 23 Controls ...... 25 Thru-drives ...... 29

PVQ25 Model Number System ...... 31 Controls (Compensators) ...... 33 Performance Curves ...... 34 Operating Data ...... 35 Controls ...... 36 Shaft Options ...... 37 Controls ...... 38

PVQ40 and PVQ45 Model Number System ...... 43 Controls (Compensators) ...... 45 Performance Curves ...... 46 Operating Data ...... 48 Controls ...... 49 Thru-drives ...... 56 Application Data ...... 60

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 2 Introduction

PVQ piston pumps are in-line, variable displacement Many PVQ pumps are available in a thru-drive units and are available in nine sizes. Displacement is configuration to accommodate a multitude of applica- varied by means of pressure and/or flow compensator tion and installation requirements. Thru-drive models controls. An impressive assortment of control options can be coupled to various types and sizes of fixed and offers maximum operating flexibility. variable displacement pumps, resulting in a compact and versatile package. Such a package offers lower PVQs operate at quietness levels that meet today’s installed cost by reducing the installation size and by demanding industrial conditions. The sound level of requiring only one mounting pad on the prime mover. each unit approaches or is below that of the electric motor driving it. Sound is reduced by a patented Quiet PVQs have excellent operating characteristics, timing arrangement that also produces low pressure and the pumps’ many control and mounting options “pulses” in the outlet flow. This leads to reduced allow choosing the optimum model for any appli- tendencies for noise in systems using PVQs. cation. Additionally, PVQs possess the same durability and long life characteristics expected of the best The PVQ series is capable of operating with many industrial products in today’s marketplace. For over types of hydraulic fluid. Water-content and phosphate 75 years, the Eaton name has been synonymous with ester fluids can be accommodated, in addition to the long trouble-free service. typical petroleum based and synthetic fluids.

Operating Data DISPLACEMENT, SPEED, AND PRESSURE RATINGS Maximum Geometric Maximum Model Displacement Rated SpeedPressure Q Series Number System cm3/r (in3/r) r/min bar (psi) Displacement, PVQ10 10,5 (0.643) 1800 210 (3000) PVQ13 13,8 (0.843) 1800 140 (2000) Speed, and PVQ20 21,1 (1.290) 1800 210 (3000) Pressure Ratings PVQ25 25,2 (1.540) 1800 210 (3000) PVQ32 32,9 (2.010) 1800 140 (2000) PVQ40 41,0 (2.500) 1800 210 (3000) PVQ45 45,1 (2.750) 1800 186 (2700) Application Data • Fluid Cleanliness • Hydraulic Fluids and Temperature Ranges • Fire Resistant Fluids • Installation and Start-up • Ordering Procedure

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 3 Model Number System PVQ10 and PVQ13

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 P V Q 1 0 A 2 R S E 1 S 2 0 C * 2 1 V * 1 1 B D 1 2 S *

Nos Feature Code Description Nos Feature Code Description 1,2,3 Series PVQ P Inline piston pump 15,16 Control type C**V**B Pressure compensator C**, as V Variable volume above with load-sensing. Q Quiet series Standard load-sensing setting 4,5 Displacement in 10 10,5 cc/rev (0.64 cir), 210 bar is 11 bar (160 psi); range cc/rev and pressure (3000 psi) 10-17 bar (150-250 psi); with ratings 13 13,8 cc/rev (0.84 cir), 140 bar bleed-down orifice. (2000 psi) Example: C21V11B indicates PVQ10 compensator with 6,7 Mounting flange A2 Flange SAE J744 82-2 (SAE A) 210 bar pressure setting and specifications MA Flange ISO 3019/2-80A2HW 11 bar load-sense differential. (available with “N” drive shaft only) C**V**P Pressure compensator with 8 Rotation viewed R Right hand (cw), standard load-sensing as C**V**B from shaft end L Left hand (ccw), optional above, but with bleed-down orifice plugged. 9,10 Ports, type and SE SAE O-ring rear port, location 1.0625” inlet C**VC**B Pressure compensator with and outlet (standard) load-sensing. Compensator SS SAE O-ring side port, same as C** above. Standard 1.3125” inlet and outlet load-sensing setting is 24 bar (optional) (350 psi), range 17-31 bar 11 Shafts, input 1 Straight keyed SAE “A” (250-450 psi). With bleed- modified, .75” dia. x 1.75” down orifice. long 3 Splined SAE “A” modified, 9T C**VC**P Pressure compensator with 16/32 DP major dia. fit load-sensing. Same as C**VC**B N Shaft end ISO 3019/2 E20N above, but with bleed-down (available with “MA” mount orifice plugged. only) CG Pressure compensator 12 Seals S Buna N, standard modified for hydraulic remote F Fluorocarbon, optional control. 13,14 Pump design 20 Design number subject to number change. Installation CD** Electric dual range dimensions remain unchanged compensator. PVQ10: CD21 is for designs 10-19. standard 210 bar setting of 15,16 Control type C** Pressure compensator. high range (24-210 bar). PVQ10: Standard model is PVQ13: CD14 is standard C21, indicating setting of 210 140 bar setting of high bar (3000 psi); range is 02-21 range (24-140 bar). Both units in tens of bar (350-3000 psi). require low range to be set by PVQ13: Standard model is customer (20-100 bar). C14, indicating factory setting of 138 bar (2000 psi); range is UV Unloading Valve for 02-14 in tens of bar accumulator circuits. (350-2000 psi). See installation details.

CM** Low pressure compensator. Standard model is CM7, indicating factory setting of 69 bar (1000 psi); range is 02-10 in tens of bar (350-1500 psi).

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 4 Model Number System PVQ10 and PVQ13

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 P V Q 1 0 A 2 R S E 1 S 2 0 C * 2 1 V * 1 1 B D 1 2 S *

Nos Feature Code Description Nos Feature Code Description 17,18 Pressure setting 21 210 bar (3000 psi) PVQ10 25,26 Control design 12 O-ring seal design 14 140 bar (2000 psi) PVQ13 27,28 Special pump S2 Shaft up mounting 19,20 Flow control option Blank No flow control option suffixes S3 British Standard Parallel V Threads Counterbore Ports VC (ISO R288 threads). Contact 21,22 Load sense Blank No flow control Eaton for available differential 11 configurations. pressure setting 24 S9 Special CG compensator for use with electronically 23 Flow control option Blank No flow control modulated relief valves. B P 24 Displacement Blank Without adjustable maximum option displacement stop (standard). D Adjustable maximum displacement stop (optional).

RATINGS Model Maximum Geometric Rated Maximum Input Power at Max. Approx. Number Displacement Speed Pressure Pressure and Rated Speed Weight System cm3/r (in3/r) r/min bar (psi) kW (hp) kg (lb) PVQ10 10,5 (0.643) 1800 210 (3000) 7,4 (10) 7,2 (16) PVQ13 13,8 (0.843) 1800 140 (2000) 6,5 (8.75) 7,2 (16) Pressure Limits: Case pressure – 0,35 bar (5 psig) maximum Inlet pressure – 0,2 bar (5 in. Hg) vacuum to 2 bar (30 psig)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 5 Controls

Pressure Compensators Remote Control Pressure Load-sensing and Pressure Standard load-sensing and The pressure compensator con- Compensator Limiting Compensators pressure limiting control with trol automatically adjusts pump Exactly the same as the “C” This compensator provides load- 11 bar differential pressure delivery to maintain volume (pressure compensation option) sensing control under all pres- (standard factory setting). requirements of the system at a except the machine operator is sure conditions up to the Includes bleed-down orifice to preselected operating pressure. able to change the compensator desired maximum. It automati- exhaust load-sense signal for Maximum pump delivery is setting through the use of a cally adjusts pump flow in low-pressure standby condition. maintained to approximately 3,4 remote pilot relief valve, such as response to a remote pressure Same as C**V11B above, but bar (50 psi) below the pressure Eaton C-175. signal and maintains outlet pres- with bleed-down orifice plugged. setting before being reduced. sure at a level slightly above load Same as C**V11B, but with fac- The pressure compensator con- Electric Dual Range Pressure pressure. The integral pressure tory differential pressure setting trol operates on one side of cen- Compensator limiter overrides the load-sens- of 24 bar. ter and has an adjustment range ing control, reducing pump dis- as designated in the model num- The dual range pressure com- placement as the preset maxi- Same as C**V11P, but with fac- bering system. pensator control automatically mum operating pressure is tory differential pressure setting adjusts pump delivery to main- reached. of 24 bar. tain volume requirements of the Pressure Compensator with system at either of two prese- Standard load-sense differential Adjustable Maximum lected operating pressures. pressure settings, by control Displacement Stop Maximum pump delivery is type, follow. See model number The adjustable maximum stop maintained to approximately 3,4 system for setting range. pressure control enables (50 psi) below either pres- maximum pump delivery to be sure control setting before being externally adjusted from 25% to reduced. 100% while maintaining all of Control type and pressure range the standard features of a pres- are designated in the model sure compensated pump. To number system. assist initial priming, manual adjustment control setting must Note: Graphic symbols shown with external be at least 40% of maximum valve(s) and cylinder to illustrate typical usage. flow position.

(†orifice open) (†orifice plugged)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 6 Performance Curves PVQ10 Oil type: SAE 10W Oil temperature: 49°C (120°F) Inlet: 0.2 bar (5 in. Hg)

Note: To obtain full flow 100% operation of pump, pres- 210 bar (3000 psi) sure compensator setting 140 bar (2000 psi) must be 14 bar (200 psi) 70 bar (1000 psi) above desired operating 80% pressure. Full flow curves 35 bar (500 psi) were obtained with com- pensator settings 14 bar 60% (200 psi) above 210 bar (3000 psi) max. rated pres-

sure. Volumetric efficiency 40%

100% 70 bar (1000 psi) 140 bar (2000 psi)

80%

35 bar (500 psi) 60% 210 bar (3000 psi) Overall efficiency 40%

l/min USgpm 32 8

24 6

140 bar (2000 psi) 16 70 bar (1000 psi) 4

Delivery 35 bar (500 psi) Delivery 8 210 bar (3000 psi) 2

0 0

kW hp 15 20

15 10 10 210 bar (3000 psi) 5 140 bar (2000 psi) Input power 70 bar (1000 psi) 5 Input power 35 bar (500 psi) 0 0 500 1000 1500 2000 Speed r/min

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 7 Performance Curves PVQ13 Oil type: SAE 10W Oil temperature: 49°C (120°F) Inlet: 0.2 bar (5 in. Hg)

Note: To obtain full flow opera- 100% tion of pump, pressure compen- sator setting must be 14 bar (200 psi) above desired operating pres- 140 bar (2000 psi) sure. Full flow curves were 80% 70 bar (1000 psi) obtained with compensator set- 35 bar (500 psi) tings 14 bar (200 psi) above 210 bar (3000 psi) max. rated pres- 60% sure. Volumetric efficiency 40%

100% 140 bar (2000 psi) 70 bar (1000 psi) 80% 35 bar (500 psi)

60% Overall efficiency 40%

l/min USgpm 32 8

24 6

16 4 140 bar (2000 psi) Delivery 70 bar (1000 psi) Delivery 8 35 bar (500 psi) 2

0 0

kW hp 15 20

15 10 10

5 140 bar (2000 psi) Input power 5 Input power 70 bar (1000 psi) 35 bar (500 psi) 0 0 500 1000 1500 2000 Speed r/min

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 8 Operating Data PVQ10 and PVQ13 Sound Data Temperature: 50°C (120°F) Test Fluid: URSA-ED (10W) Inlet Pressure: Atmospheric (0 psig)

SOUND DATA Sound Level dB(A)* Full Stroke Cutoff Speed r/min Pressure bar (psi) PVQ10 PVQ13 PVQ10 PVQ13 1000 35 (500) 51 53 43 42 70 (1000) 55 54 48 50 100 (1500) 56 55 50 52 140 (2000) 57 61 51 56 175 (2500) 59 – 51 – 1200 35 (500) 53 54 46 44 70 (1000) 55 54 49 52 100 (1500) 56 58 51 56 140 (2000) 57 65 53 57 175 (2500) 60 – 54 – 1500 35 (500) 56 56 47 44 70 (1000) 59 59 49 51 100 (1500) 59 60 51 55 140 (2000) 60 67 53 56 175 (2500) 62 – 53 – 1800 35 (500) 58 58 52 49 70 (1000) 60 61 53 56 100 (1500) 62 63 55 58 140 (2000) 63 – 57 – 175 (2500) 65 – 57 – *Sound pressure data equivalent to NFPA Standard. Note: To ensure maximum noise reduction at full flow conditions, Engineering recommends limiting pressure of PVQ10 to 175 bar (2500 psi) and PVQ13 to 100 bar (1500 psi) at 1800 rpm.

PVQ10 RESPONSE DATA PVQ10 PVQ13 and PVQ13 Control Type On stroke Off stroke On stroke Off stroke Response Data Pressure compensator 0.040 sec. 0.020 sec. 0.048 sec. 0.016 sec. Yoke response recorded at rated speed and pressure, 0 psi inlet, 82°C (180°F), SAE 10W oil. Pressure rise was 6900 bar (100,000 psi) per second.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 9 Installation Dimensions PVQ10 and PVQ13 with Rear Ports Millimeters (inches)

Compensator position Case drain connection for R.H. rotation models 177 Caution: While pump is operating do .562-18 UN-2B straight (6.97) not back compensator adjustment thíd for .375 O.D. screw out beyond dimension shown. tubing 162,8 Compensator (6.41) Outlet connection for R.H. 20,6 1 108,7 rotation models 1 /16-12 (0.81)R (4.28) UN-2B straight thd. (0.75 28,4 position for O.D. tubing) 44,4 69,8 (1.12) L.H. rotation (1.75) models (2.75) 28,4 84,8 84,8 130 6,3(0.25) 12,7 (1.12) (3.34) (3.34) (5.12)D 6,1(0.24) (0.50) Model number shown here 79,2 50 (3.12) (1.97) 82,55 (3.250) 82,50 (3.248) D 38,1 A B (1.50) 52,3 (2.06) 33,5 16,8 21,13 (0.832) (1.32) (0.66) 163,6 28,6 53,2 47,7 21,00 (0.827) (1.125) Right hand 11,1 (6.44) 57,1 rotation (2.09) (1.88)R Alternate (0.437)D 4,79 (0.1885) 25,4 Compensator (2.250) case drain 106,4 2 holes square adjustment 67,8 connection 4,76 (0.1875) (1.00) (2.67) (4.188) screw 0.94 hex 135,9 19,05 (0.750) (5.35) 19,02 (0.749) D Direction of rotation shown here Outlet connection for L.H. rotation models 11/16 -12 UN-2B straight thd. (0.75 O.D. tubing)

PVQ10 and Outlet connection 1.3125-12 UN-2B straight thd. (1.00 O.D. PVQ13 with 153,2 tubing) for R.H. rotation models Side Ports (6.03)

79,2 50 (3.12) (1.970) Port Port A B 38,1 52,3 (1.50) (2.06)

177 82,5 (6.97) (3.250) Outlet connection 1.3125-12 165,1 UN-2B straight thd. (1.00 O.D. (6.500) tubing) for L.H. rotation models

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 10 Shaft Options

No. 3 Shaft “N” Shaft with “MA” Flange (Flange and shaft end ISO 3019/2-80A2HW-E20N)

31,7 (1.25) 22,51 22,38 22,00 23,8 (0.886) (0.866) (0.938) (0.881) 11,27 79,98 (0.444) 0.6249 Major 79,93 0.6245 Dia. (3.149) (3.147) 20,001 19,99 36,0 5,99 (0.788) (1.42) 5,97 (0.787) (0.234) 8,51 (0.235) SAE standard involute spline flat root (0.335) Square key major diameter fit. 9 teeth 16/32 pitch 7,24 54,50 diameter ref. .4835/.4725 minor diameter (0.285) (2.15) 109,00 (4.29)

Controls Load-sensing Remote with Pressure Load sensing comp. control To mounting face port location for R.H. Compensator Limiting of pump mtg. flg. rotation .4375-20 UNF-2B Compensator boss connection Adjustment 167,39 (6.59) 1. Turn pressure control (such 190,75 as C-175) CCW to minimum (7.51) setting. 2. Turn compensator adjust- ment plug to desired minimum pressure (17 bar, 250 psi or higher). 3. Full pressure range can now Load sensing control port 45,1 19,05 be obtained with pressure (1.775) location for L.H. rotation control. (0.75) 28,45 Caution: Effective compensator (1.12) pressure will be compensator Max. control setting (17-69 bar, 250-1000 psig) plus remote relief valve setting. .4375-20 UNF-2B Do not operate pump 28,45 D thread for "CG" with this port plugged. (1.12) Compensator adj. knob. control models. Do not back out adj. knob Connect to pressure beyond 28,4 (1.12) dim. control, such as shown while pump is C-175. SAE O-ring operating. boss connection .250 O.D. tubing

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 11 Shaft Options

No. 3 Shaft “N” Shaft with “MA” Flange (Flange and shaft end ISO 3019/2-80A2HW-E20N)

31,7 (1.25) 22,51 22,38 22,00 23,8 (0.886) (0.866) (0.938) (0.881) 11,27 79,98 (0.444) 0.6249 Major 79,93 0.6245 Dia. (3.149) (3.147) 20,001 19,99 36,0 5,99 (0.788) (1.42) 5,97 (0.787) (0.234) 8,51 (0.235) SAE standard involute spline flat root (0.335) Square key major diameter fit. 9 teeth 16/32 pitch 7,24 54,50 diameter ref. .4835/.4725 minor diameter (0.285) (2.15) 109,00 (4.29)

Controls Load-sensing Remote with Pressure Load sensing comp. control To mounting face port location for R.H. Compensator Limiting of pump mtg. flg. rotation .4375-20 UNF-2B Compensator boss connection Adjustment 167,39 (6.59) 1. Turn pressure control (such 190,75 as C-175) CCW to minimum (7.51) setting. 2. Turn compensator adjust- ment plug to desired minimum pressure (17 bar, 250 psi or higher). 3. Full pressure range can now Load sensing control port 45,1 19,05 be obtained with pressure (1.775) location for L.H. rotation control. (0.75) 28,45 Caution: Effective compensator (1.12) pressure will be compensator Max. control setting (17-69 bar, 250-1000 psig) plus remote relief valve setting. .4375-20 UNF-2B Do not operate pump 28,45 D thread for "CG" with this port plugged. (1.12) Compensator adj. knob. control models. Do not back out adj. knob Connect to pressure beyond 28,4 (1.12) dim. control, such as shown while pump is C-175. SAE O-ring operating. boss connection .250 O.D. tubing

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 12 8 Controls Electric Dual Range Pressure Compensator Control

Adjustment 1. With the directional valve de- energized, loosen locknut “5” and turn the adjusting screw “4” to the desired first stage pressure setting, then tighten locknut “5.” 2. With solenoid de-energized, turn adjusting spool “1” counterclockwise (CCW) until nut “3” is bottomed in adjusting screw slot. (Second stage setting is now equal to 1. Adjusting spool — sets first stage pressure setting.) 288,5 Turn adjusting spool clock- second stage pressure (11.36) wise (CW) to desired second stage pressure requirements. One complete turn of ad- 2. Locknut — 17,3 (0.68) justing spool equals approxi- across flats mately 41 bar (600 psi). 3. Locknut — must be Energize solenoid and check contained within slot of pressure setting. De-energize adjusting screw as shown solenoid and re-adjust if nec- essary. Secure this setting by 4. Adjusting screw 25,4 tightening locknut “2.” (1.00) across flats — sets first stage pressure 5. Locknut — 31,7 (1.25) across flats 158,7 158,7 (6.25) (6.25)

50 (1.97)

Position for Dual range pressure R.H. models compensator position Electrical conduit conn.1 /2 NPTF thd.

Inrush amps Solenoid Data Solenoid current (R.M.S.) Holding amps (110V AC 50 Hz 115/120V AC 60 Hz - .54 110V AC 50 Hz2.0 .64* and 115/120V AC *Maximum peak inrush amps approximately 1.4 x R.M.S. value shown. 60 Hz) Refer to catalog GB-C-2015B for additional solenoid valve data.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 13 Controls Electric Dual Range Pressure Compensator with Maximum Displacement Stop

Maximum Flow Adjustment With the system pressure below both compensator settings, loosen maximum stop adjusting Electrical conduit screw locknut and adjust screw connection 1/2 to desired flow position (turning NPTF thd. screw clockwise decreases flow Minimum delivery and turning screw counterclock- position (flush with nut). Do not adjust below flush. 170,4 wise increases flow). To lock (6.71) Position for screw in position tighten lock- R.H. models nut. To assist initial priming, adjust control setting to at least 40% of maximum flow position.

Compensator Control 22,9 1. With the directional valve (0.90) de-energized, loosen locknut 168,4 168,4 “5” and turn the adjusting (6.63) 50 15,7 (6.63) screw “4” to the desired first (1.97) Locknut 1 1,2 (0.44) across flats (0.62) stage pressure setting, then Maximum stop (adjusting screw) tighten locknut “5.” .250-20 UNC thd. 2. With directional valve Maximum delivery position de-energized, turn adjusting spool “1” counterclockwise until nut “3” is bottomed in adjusting screw slot. (Second stage setting is now equal to first stage pressure setting.) 1. Adjusting spool — sets Turn adjusting spool clock- second stage pressure 212,8 wise to desired second stage (8.38) pressure requirements. One complete turn of adjusting spool equals approximately 41 bar (600 psi). Energize solenoid and check pressure 91,4 setting. De-energize solenoid 2. Locknut — 17,3 (0.68) (3.60) and re-adjust if necessary. across flats Secure this setting by tight- 3. Locknut — must be ening locknut “2.” contained within slot of adjusting screw as shown 4. Adjusting screw 25,4 (1.00) across flats — sets first stage pressure 5. Locknut — 31,7 (1.25) across flats

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 14 Controls Unloading Valve Control

With the unloading valve control Setting Pressures the variable pump will unload at 1. Back out accumulator un- a preset pressure. The pump will loading pressure adjustment maintain this no flow, low pres- screw to below desired Unload valve sure (approximately 14 bar [200 unloading pressure. psi]) standby condition, until sys- control port tem pressure drops to about 2. Adjust desired standby To l o a d 85% of the preset unloading pressure. pressure. The pump will then 3. Set accumulator pressure by Inlet return on stroke and provide full screwing in Check Valve flow until the preset unloading the accumulator unloading pressure is reached again. adjustment screw. With this control, an efficient Accumulator recharge (cut-in) Outlet accumulator charging circuit is pressure is a function of the obtained. The pump will provide maximum accumulator pres- Drain full flow to fill the accumulator sure and is not adjustable. until the maximum charging 4. Check pressure settings and pressure is reached. The pump re-adjust if necessary. then goes to a standby condition until the accumulator pressure drops to 85% of the desired Standby pressure maximum. The accumulator is adjustment then recharged as the cycle Control Port .4375-20 Accumulator unloading UNF-2B thd. SAE O-ring boss starts over again. pressure adjustment connection .25 OD tubing A separate right angle check valve must be provided to main- 145,5 tain the accumulator hydraulic (5.95) charge and prevent back flow when the pump is unloaded. The 79,2 check valve’s internal leakage (3.12) 50,0 must not exceed five drops per (1.97) minute. The control port must be Port Port connected to system pressure, A B downstream of the check valve.

Adjustment range PVQ10 100-210 bar (1500-3000 psi) 56,1 PVQ13 100-140 bar (1500-2000 psi) (2.21) Cut-in pressure is 85% of unloading pressure, minimum. 225,3 198,4 (8.87) (7.82) 164,3 (6.57)

70,6 (2.78)

29,5 52,3 (1.16) (2.06)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 15 Model Number System PVQ20 and PVQ32

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 P V Q 2 0 A 2 R A 9 S E 1 S 2 1 C * 2 1 V * 1 1 B D 1 2 S *

Nos Feature Code Description Nos Feature Code Description 1,2,3 Series PVQ P Inline piston pump CM** Low pressure compensator. V Variable volume Standard model is CM7, Q Quiet series indicating factory setting of 4,5 Displacement in 20 21,1 cc/rev (1.29 cir), 210 bar 70 bar (1000 psi); range is cc/rev and pressure (3000 psi) 02-10 in tens of bar ratings 32 32,9 cc/rev (2.01 cir), 140 bar (350-2000 psi). (2000 psi) C**V**B Pressure compensator C**, as above with load-sensing. 6,7 Mounting flange B2 Flange SAE J744 101-2 (SAE B) Standard load-sensing setting specifications MB Flange ISO 3019/2-100A2HW is 11 bar (160 psi); range 10-17 (available with N” drive shaft bar (150-250 psi); with bleed- only) down orifice. Example: 8 Rotation viewed R Right hand (cw), standard C21V11B indicates PVQ20 from shaft end L Left hand (ccw), optional compensator with 210 bar pressure setting and 9,10 Thru-drive without Blank No thru-drive 11 bar load-sense differential. coupling (available A9 SAE J744 82-2 (SAE A) w/9T C**V**P Pressure compensator with spline with side ports only) load-sensing as C**V**B A11 SAE J744 82-2 (SAE A) w/11T above, but with bleed-down spline orifice plugged. 11,12 Ports, type and SE SAE O-ring rear port, C**VC**B location 1.625” inlet and outlet Pressure compensator with (standard) load-sensing. Compensator SS SAE O-ring side port, same as C** above. Standard 1.625” inlet and outlet load-sensing setting is 24 bar (optional) (350 psi), range 17-31 bar (250-450 psi). With bleed- 13 Shafts, input 1 Straight keyed SAE “B” down orifice. modified, 2.31'' long C**VC**P Pressure compensator with 3 Splined SAE “B” modified, 13T load-sensing. Same as 16/32 DP major dia. fit C**VC**B above, but with N Shaft end ISO 3019/2 E25N bleed-down orifice plugged. (available with “MB” mount only) CG Pressure compensator 28 26-tooth splined shaft (Eaton). modified for hydraulic remote Used in PVQ20/32 single to control. mount on PVQ40/45 “B26” CD** Electric dual range compensator. thru-drive. PVQ20: CD21 is standard 210 14 Seals S Buna N, standard bar setting of high range F Fluorocarbon, optional (24-210 bar). PVQ32: CD14 is 15,16 Pump design 21 Design number subject to standard 140 bar setting of high number change. Installation dimensions range (24-140 bar). Both units remain unchanged for designs require low range to be set by 10-19. customer (20-100 bar). UV Unloading Valve for accumultor 17,18 Control type C** Pressure compensator. PVQ20: circuits. See installation details. Standard model is C21, indicating setting of 210 bar (3000 psi); range is 02-21 in tens of bar (350-3000 psi). PVQ32: Standard model is C14, indicating factory setting of 138 bar (2000 psi); range is 02-14 in tens of bar (350-2000 psi).

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 16 Model Number System PVQ20 and PVQ32

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 P V Q 2 0 A 2 R A 9 S E 1 S 2 1 C * 2 1 V * 1 1 B D 1 2 S *

Nos Feature Code Description Nos Feature Code Description 19,20 Pressure setting 21 210 bar (3000 psi) PVQ20 27,28 Control design 12 C** and CM** 14 140 bar (2000 psi) PVQ32 12 C**D and CM**D 21,22 Flow control option Blank No flow control 13 C**V(C)**B and C**V(C)**P V 21 UV, CD** CG 30 VC 29,30 Special pump S2 Shaft up mounting 23,24 Load sense Blank No flow control option suffixes S3 British Standard Parallel differential Threads Counterbore Ports pressure setting (ISO R288 threads). Contact Eaton for available 25 Flow control Blank No flow control configurations. optional features B S9 Special CG compensator for P use with electronically 26 Control option Blank Without adjustable maximum modulated relief valves displacement stop (standard) D Adjustable maximum displacement stop (optional)

RATINGS Model Maximum Geometric Rated Maximum Input Power at Max. Approx. Number Displacement Speed Pressure Pressure and Rated Speed Weight System cm3/r (in3/r) r/min bar (psi) kW (hp) kg (lb) PVQ20 21,1 (1.290) 1800 210 (3000) 14,9 (20) 14 (31) PVQ32 32,9 (2.010) 1800 140 (2000) 15,6 (21) 14 (31) Pressure Limits: Case pressure – 0,35 bar (5 psig) maximum Inlet pressure – 0,2 bar (5 in. Hg) vacuum to 2 bar (30 psig)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 17 Controls

Pressure Compensator Remote Control Pressure Load-sensing and Pressure Standard load-sensing and pres- Controls Compensator Limiter Compensator Control sure limiting control with 11 bar The pressure compensator con- Exactly the same as the “C” This compensator provides differential pressure (standard trol automatically adjusts pump (pressure compensation option) load-sensing control under all factory setting). Includes bleed- delivery to maintain volume except the machine operator is pressure conditions up to the down orifice to exhaust load- requirements of the system at a able to change the compensator desired maximum. It automati- sense signal for low-pressure preselected operating pressure. setting through the use of a cally adjusts pump flow in standby condition. Maximum pump delivery is remote pilot relief valve, such as response to a remote pressure Same as C**V11B above, but maintained to approximately 75 Eaton C-175. signal and maintains outlet pres- with bleed-down orifice plugged. psi (PVQ20) or 100 psi (PVQ32) sure at a level slightly above load Same as C**V11B, but with fac- below the pressure setting Electric Dual Range Pressure pressure. The integral pressure tory differential pressure setting before being reduced. The pres- Compensator Control limiter overrides the load-sens- of 24 bar. sure compensator control oper- ing control, reducing pump dis- ates on one side of center and The dual range pressure com- placement as the preset maxi- Same as C**V11P, but with fac- has an adjustment range as des- pensator control automatically mum operating pressure tory differential pressure setting ignated in the model numbering adjusts pump delivery to main- is reached. of 24 bar. system. tain volume requirements of the system at either of two prese- Standard load-sense differential lected operating pressures. pressure settings, by control Pressure Compensator Control type, follow. See model number with Adjustable Maximum Maximum pump delivery is system for setting range. Displacement Stop maintained to approximately 75 psi (PVQ20) or 100 psi (PVQ32) The adjustable maximum stop below either pressure control pressure control enables the setting before being reduced. maximum pump delivery to be externally adjusted from 25% to Control type and pressure range 100% while maintaining all of are designated in the model the standard features of a pres- number system. sure compensated pump. To Note: Graphic symbols shown with external assist initial priming, manual valve(s) and cylinder to illustrate typical adjustment control setting must usage. be at least 40% of maximum flow position.

(†orifice open) (†orifice plugged)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 18 Performance Curves PVQ20 Oil type: SAE 10W Oil temperature: 49°C (120°F) Inlet: 0.2 bar (5 in. Hg)

Note: To obtain full flow oper- 100% ation of pump, pressure com- 35 bar (500 psi) pensator setting must be 14 70 bar (1000 psi) bar (200 psi) above desired operating pressure. Full flow 80% 140 bar (2000 psi) curves were obtained with 210 bar (3000 psi) compensator settings 14 bar (200 psi) above 210 bar 60% (3000 psi) max. rated pressure. Volumetric efficiency

100%

70 bar (1000 psi) 80% 140 bar (2000 psi) 210 bar (3000 psi) 35 bar (500 psi) 60% Overall efficiency 40%

l/min USgpm 40 10

32 8

24 6 35 bar (500 psi) 70 bar (1000 psi)

Delivery 16

140 bar (2000 psi) 4 Delivery 210 bar (3000 psi)

8 2

0 0

kW hp 15 20

210 bar (3000 psi) 15 10 140 bar (2000 psi) 70 bar (1000 psi) 10 35 bar (500 psi) 5 Input power 5 Input power

0 0 500 1000 1500 2000 Speed r/min

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 19 Performance Curves PVQ32 Oil type: SAE 10W Oil temperature: 49°C (120°F) Inlet: 0.2 bar (5 in. Hg)

Note: To obtain full flow oper- 100% ation of pump, pressure com- 35 bar (500 psi) pensator setting must be 14 bar (200 psi) above desired 70 bar (1000 psi) operating pressure. Full flow 80% 140 bar (2000 psi) curves were obtained with compensator settings 14 bar (200 psi) above 140 bar (2000 60% psi) max. rated pressure.

Volumetric efficiency 40%

100% 140 bar (2000 psi) 70 bar (1000 psi) 35 bar (500 psi) 80%

60% Overall efficiency 40%

l/min USgpm 76 20

57 15

38 Delivery 10 Delivery 140 bar (2000 psi) 70 bar (1000 psi) 19 35 bar (500 psi) 5

0 0

kW hp 15 20

15 10

140 bar (2000 psi) 10 5 70 bar (1000 psi)

Input power 35 bar (500 psi) 5 Input power

0 0 500 1000 1500 2000 Speed r/min

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 20 Operating Data PVQ20 and PVQ32 Sound Data Temperature: 50°C (120°F) Test Fluid: URSA-ED (10W) Inlet Pressure: Atmospheric (0 psig)

SOUND DATA Sound Level dB(A)* Full Stroke Cutoff Speed r/min Pressure bar (psi) PVQ20 PVQ32 PVQ20 PVQ32 1000 35 (500) 53 58 43 47 70 (1000) 56 59 47 50 140 (2000) 57 61 52 54 210 (3000) 59 – 54 – 1200 35 (500) 55 61 43 47 70 (1000) 58 62 48 51 140 (2000) 59 63 52 54 210 (3000) 61 – 55 – 1500 35 (500) 57 63 47 50 70 (1000) 59 65 51 54 140 (2000) 61 65 56 55 210 (3000) 62 – 59 – 1800 35 (500) 60 66 50 53 70 (1000) 62 67 53 56 140 (2000) 63 68 58 62 210 (3000) 64 – 58 – *Sound pressure data equivalent to NFPA Standard.

PVQ20 RESPONSE DATA PVQ20 PVQ32 and PVQ32 Control Type On stroke Off stroke On stroke Off stroke Response Data Pressure compensator 0.070 sec. 0.023 sec. 0.080 sec. 0.020 sec. load-sense compensator 0.090 sec. 0.015 sec. 0.100 sec. 0.018 sec. Yoke response recorded at rated speed and pressure, 0 psi inlet, 82°C (180°F), SAE 10W oil. Pressure rise was 6900 bar (100,000 psi) per second.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 21 Shaft Torque Data PVQ20/32A9 and PVQ20/32A11

Thru-drive Shaft Torque Data THRU-DRIVE SHAFT TORQUE DATA Any deviation from these Model Maximum Input Maximum Thru-drive maximum torque values must Number Torque Total Torque Output System* Input Shaft Code Nm (lb. in.) Nm (lb. in.) be approved by Eaton engineering. PVQ20/32A9 1 135 (1200) 3 208 (1850) 58 (517) N 337 (2987) PVQ20/32A11 1 135 (1200) 3 208 (1850) 123 (1100) N 337 (2987) *SAE “B” 4 inch thru-drive pilot not available in PVQ20/32 frame size.

Installation Dimensions Vertical “Shaft-up” Installation – “S2” Drain Port Option

29,2 Additional drain port, (1.15) 3/4"-16 UNF-2B

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 22 Installation Dimensions Rear Ports, “C” and “CM” Controls, No. 1 Shaft

208 (8.19) Compensator Case drain 189 position for R.H. Compensator connection 58,7 (7.44) rotation models 66,5 position for L.H. .7500-16 146 (2.62) (5.750) (2.31) 123,7 84,8 rotation models UNF-2B (4.87) 33,3 (3.34) 28,4 straight thd. 73 9,5 74,7 (1.31) (2.88) 28,4 (1.12)D (for 0.50 6,4 (0.251) (.375) (2.94) O.D. tubing) Sq. key (1.12) 6,3 (0.250) 82,5 (3.25) 45,7 101,6 (4.000) AB (1.80) 101,5 (3.998) 52,3 65 (2.06) (2.56) 22,9 (0.90) 93,5 Outlet connection for 120,6 25,1 (0.989) 12,7 24,9 (0.979) (0.50) (3.68) R.H. rotation models – 14,3 (0.562)D (4.75)D 193,8 186,9 1.6250-12 UN-2B thd. 2 holes (for mounting) 22,22 (0.875) (7.63) Outlet connection for (7.36) (for 1.25 O.D. tubing) Right hand rotation 22,20 (0.874)D L.H. rotation models – 1.6250-12 UN-2B thd. Alternate case drain connection (for 1.25 O.D. tubing) .7500-16 UNF-2B straight thd. (for 0.50 O.D. tubing) Caution– while pump is operating do not back compensator adjustment screw out beyond dimension shown.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 23 Installation Dimensions

Side Ports Case drain connection .7500-16 UNF-2B straight thd. (for 0.50 O.D. tubing) 174,5 28,4 61 108,7 (6.87) (1.12) (2.40) (4.28) 52,4 (2.062) 82,5 (3.25)

31,7 65 (1.25) (2.56)

1.6250-12 UN-2B thd. inlet or Outlet connection for 98,5 (3.88) Outlet connection for outlet connection – 2 places L.H. rotation models 196,8 R.H. rotation models (for 1.25 O.D. tubing) (7.75) Alternate case drain connection .7500-16 UNF-2B straight thd. (for 0.50 O.D. tubing) No. 3 Shaft 31,7 22,2 (1.25) 22,1 (0.873) 28,01 (0.872) 23,8 27,71 Major (0.938) (1.103 Dia. (1.09 100 99,95 D (3.937) (3.935) 2 2 (0 (0

SAE standard involute spline flat root major diameter fit. 13 teeth 16/32 pitch 0.8125 pitch diameter (ref.) 0.7335/0.7225 minor diameter

“N” Shaft with 8,00 7,96 “MB” Flange (0.315) (0.314) (Flange and shaft end ISO 28,01 Square key 3019/21000A2HW-E25N) 27,71 (1.103) (1.091) 14,25 (0.56) 100 99,95 D (3.937) (3.935) 25,006 24,994 D 42,0 (0.9845) (1.65) (0.9840)

or 10,5 (0.413) itch 9,25 70,00 eter (0.364) (2.76) 140,00 (5.51)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 24 Controls

Remote Load-sensing Compensator with Pressure Limiter Adjustment To mounting face 1. Turn pressure control (such of pump mtg. flg. as C-175) CCW to minimum setting. Load sensing comp. control 2. Turn compensator adjust- port location for R.H. ment plug to desired mini- 167,39 rotation .4375-20 UNF-2B mum pressure (17 bar, (6.59) boss connection 250 psi or higher). 190,75 3. Full pressure range can now (7.51) be obtained with pressure control. Caution: Effective compensator pressure will be compensator control setting (17-69 bar, 250-1000 psig) plus remote relief valve setting. 45,1 Load sensing control port (1.775) 19,05 location for L.H. rotation (0.75) 28,45 (1.12) Max.

.4375-20 UNF-2B Do not operate pump 28,45 D Compensator adj. knob. thread for "CG"control models. with this port plugged. (1.12) Do not back out adj. knob Connect to pressurecontrol, such as beyond 28,4 (1.12) dim. shown while pump is C-175. SAE O-ring boss connection operating. .250 O.D. tubing

Pressure Minimum delivery position Compensator (screw flush with nut) do not adjust below flush. 70,9 118,7 28,4 Control with 265,7 (2.79) (4.66) (1.12) (10.46) Adjustable Max. 226,1 28,4 D 23,9 (8.90) (1.12) (0.94) Displacement 17,3 (0.68) Stop 90,2 52,3 (3.55) Adjustment (2.06) Loosen locknut on adjusting AB rod. Turn adjusting rod clockwise 25,1 (CW) to decrease maximum (0.99) pump delivery or counter- clockwise (CCW) to increase Locknut 1— 1,2 (0.44) Adjusting rod maximum pump delivery until across flats (Approx. cc/rev Adjustable maximum stop desired setting is obtained. change per turn: pressure compensator control Secure this setting by tightening PVQ20 – 1.88 position on left hand models locknut. PVQ32 – 2.82)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 25 Controls

Electric Dual Range Pressure Compensator Control

Adjustment 1. With the directional valve de- energized, loosen locknut “5” and turn the adjusting screw “4” to the desired first stage pressure setting, then tighten 1. Adjusting spool — sets 318,2 locknut “5.” second stage pressure (12.53) 2. With solenoid de-energized, turn adjusting spool “1” counterclockwise (CCW) until 2. Locknut — 17,3 (0.68) nut “3” is bottomed in across flats adjusting screw slot. (Second 3. Locknut — must be stage setting is now equal to contained within slot of first stage pressure setting.) adjusting screw as shown Turn adjusting spool clock- wise (CW) to desired second 4. Adjusting screw 25,4 stage pressure requirements. (1.00) across flats — sets One complete turn of adjust- first stage pressure ing spool equals approxi- 5. Locknut — 31,7 (1.25) mately 41 bar (600 psi). 134,9 158,7 across flats Energize solenoid and check (5.31) (6.25) pressure setting. De-energize solenoid and re-adjust if nec- essary. Secure this setting by tightening locknut “2.” 52,3 (2.06)

Dual range pressure Position for compensator position L.H. models

Electrical conduit conn. 1/2 NPTF thd.

Inrush amps Solenoid Data Solenoid current (R.M.S.) Holding amps (110V AC 50 Hz 115/120V AC 60 Hz – .54 110V AC 50 Hz 2.0 .64* and 115/120V AC *Maximum peak inrush amps approximately 1.4 x R.M.S. value shown. 60 Hz) Refer to catalog GB-C-2015B for additional solenoid valve data.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 26 Controls Electric Dual Range Pressure Compensator with Maximum Displacement Stop

Maximum Flow Adjustment With the system pressure below both compensator settings, loosen maximum stop adjusting screw locknut and adjust screw to desired flow position (turning screw clockwise decreases flow and turning screw counterclock- wise increases flow). To lock screw in position, tighten lock- nut. To assist initial priming, 201,7 adjust control setting to at least (7.94) Position for 40% of maximum flow position. L.H. models

Compensator Control 1. With the directional valve de- energized, loosen locknut “5” and turn the adjusting screw 25,1 “4” to the desired first stage (0.99) pressure setting, then tighten locknut “5.” 23,9 52,3 (0.94) 2. With directional valve de- Electrical conduit (2.06) Locknut 1– 1 ,2 (0.44) across flats 1 energized, turn adjusting connection /2 NPTF thd. Minimum delivery Maximum stop (adjusting screw) spool “1” counterclockwise position (flush with until nut “3” is bottomed in nut). Do not adjust .250-20 UNC thd. adjusting screw slot. (Second below flush. Maximum delivery position stage setting is now equal to first stage pressure setting.) Turn adjusting spool clock- wise to desired second stage pressure requirements. One complete turn of adjusting spool equals approximately 41 bar (600 psi). Energize solenoid and check pressure 1. Adjusting spool — sets setting. De-energize solenoid second stage pressure and re-adjust if necessary. Secure this setting by tight- 215,1 ening locknut “2.” (8.47) 2. Locknut — 17,3 (0.68) across flats 93,5 (3.68) 3. Locknut — must be contained within slot of adjusting screw as shown 4. Adjusting screw 25,4 (1.00) across flats — sets first stage pressure 144,5 192,3 5. Locknut — 31,7 (1.25) (5.69) (7.57) across flats

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 27 Controls Unloading Valve Control

With the unloading valve control Adjustment range the variable pump will unload at PVQ20 100-210 bar a preset pressure. The pump will (1500-3000 psi) maintain this no flow, low pres- PVQ32 100-140 bar Unload valve sure (approximately 14 bar [200 (1500-2000 psi) control port psi]) standby condition, until sys- tem pressure drops to about Cut-in pressure is 85% of To l o a d 85% of the preset unloading unloading pressure, minimum. pressure. The pump will then Inlet return on stroke and provide full Setting Pressures Check Valve flow until the preset unloading 1. Back out accumulator unload- pressure is reached again. ing pressure adjustment With this control, an efficient screw to below desired Outlet accumulator charging circuit is unloading pressure. Drain obtained. The pump will provide 2. Adjust desired standby full flow to fill the accumulator pressure. until the maximum charging pressure is reached. The pump 3. Set accumulator pressure by then goes to a standby condition screwing in the accumulator until the accumulator pressure unloading adjustment screw. drops to 85% of the desired Accumulator recharge (cut-in) pressure is a function of the maximum. The accumulator is 246,4 then recharged as the cycle maximum accumulator pres- (9.70) starts over again. sure and is not adjustable. 174,5 A separate right angle check 4. Check pressure settings and (6.87) valve must be provided to main- re-adjust if necessary. 174,5 tain the accumulator hydraulic (6.87) charge and prevent back flow when the pump is unloaded. The check valve’s internal leakage must not exceed five drops per minute. The control port must be connected to system pressure, 65,0 downstream of the check valve. (2.56)

Standby pressure Accumulator unloading adjustment pressure adjustment Control Port .4375-20 UNF-2B thd. SAE O-ring boss connection .25 OD tubing

145,5 (5.95)

82,5 (3.25) 52,4 (2.06)

56,1 (2.21) EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 28 Thru-drives PVQ20/32 “A9” and “A11” SAE “A”

No. 1 shaft. Input torque not to exceed 73 Nm (650 lb. in.) plus tabulated auxiliary pump torque with no overhung load. Applications requiring overhung load capability or other shaft ends are subject to approval by Vickers Engineering. Note: Ports are reversed for L.H. rotation. Control location same for both L.H. and R.H. rotation. 101,6 (4.00) 101,5 (3.998) 6,4 (0.251) 6,3 (0.250)

22,22 (0.875) 22,20 (0.874) 20,6 20,6 (0.81) 174,7 (0.81) (6.88) Caution: While pump is operating, do not back compensator adj. out Construction plug. Do not remove. beyond 28,4 (1.12) dim. shown. Drain port .7500-16 UNF-2B thd. SAE O-ring boss conn. .500 O.D. tubing. 129,3 166,1 (5.09) 11,2 (6.54) 28,4 (0.44) Drain port .7500-16 7,9 47,5 123,4 UNF-2B thd. SAE O-ring (0.31) (1.12) (1.87) (4.86) boss conn. .500 O.D. tubing 82,5 .375-16 UNC-2B thd. 110,2 (3.25) 18,3 (0.72) deep 96 (4.34) (3.78)

18,7 (0.738) 76,7 18,5 (0.729) (3.02) Outlet port R.H. 9,6 see note. (0.39) 12,7 106,4 1.6250-12 UN-2B 25,1 (0.989) Inlet port R.H. see 24,9 (0.979) 74,7 (0.50) 98,5 (4.19) thd. SAE O-ring (2.94) note. 1.6250-12 boss connection 162 UN-SAE str. thd. (3.88) (6.38) 196,8 1.250 O.D. tubing 230,6 SAE O-ring boss (7.75) (9.08) connection 1.250 O.D. tubing Alternate drain port .7500-16 UNF-2B thd. SAE O-ring boss connection .500 O.D. tubing

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 29 Thru-drives PVQ20/32 “A9” and “A11” SAE “A”

187 (7.36) 93,5 (3.68)

120,6 (4.75) Note: Ports are reversed for L.H. rotation. Control location same for both L.H. and 4,8 R.H. rotation. (0.188) 31,7 (1.25)

14,3 (0.562) 2 places 73,1 (2.88) 146,05 (5.75)

Output spline (see table)

82,6 Thru-Drive (3.252) Cutaway View Use O-ring AS568-042 at interface of auxiliary pump mounting A See table B

PVQ20/32 “A9” AND “A11” SAE “A” Installation Dimensions mm (in) Max. Torque Model Number System Spline Data Nm (in. lb.) A B Coupling Kit “A9” ASA B5.15-1960 9 teeth 16/32 DP 58 (517) 16,7 (0.66) 33,0 (1.30) 02-136810 Flat root side fit “A11” ANS B92.1-1970 11 teeth 16/32 DP 123 (1100) 18,5 (0.73) 39,1 (1.54) 02-306041 Flat root side fit Note: O-ring included with pump. Coupling kit, cap screws, and washers must be ordered separately to mount rear pump.

Typical TYPICAL REAR PUMPS (WITH SHAFT CODES) FOR PVQ20/32 THRU-DRIVES Model Series Typical Rear Pump Rear Pump Shaft Code Thru-drive Coupling Kit Rear Pumps PVQ10/13 3 PVB5/6 S124 suffix (with shaft codes) “A9” 02-136810 V10 11 for PVQ20/32 V20 62 Thru-drives Note: “A11” (not listed above) is intended for special application only.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 30 Model Number System PVQ25

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 P V Q2 5 A R 1 1 A A 1 0 B 1 1 2 4 0 0 A 2 0 0 1 A P C 9 0 1

Nos Feature Code Description Nos Feature Code Description 1,2 Code title PV Open circuit piston pump 13 Diagnostic pressure 0 No diagnostic pressure point 3,4,5,6 Displacement Q25A 25.2cm3/r [1.54 in3/r] point 7 Input shaft rotation L Left-hand rotation (CCW) 14 Controller type C Electric dual range pressure R Right-hand rotation (CW) Compensator with directional control valve 8,9 Front mounting and 01 2 Bolt B (SAE J744-101-2) with E Unloading valve (accumulator input shaft 22.2 [.88] DIA straight keyed circuits) shaft (SAE J744-22-1), key G Adjustable pressure included compensator 05 2 Bolt B (SAE J744-101-2) with H Adjustable pressure and flow 13T 16/32DP 41.1 [1.62] long compensator splined shaft J Adjustable hydraulic remote 09 2 Bolt B (SAE J744-101-2) with control pressure compensator 26T 32/64DP splined shaft 10 Shaft-2 Bolt VDMA A with 25.0 15,16 Pressure comp./ 07 65.5-72.4 bar [950-1050 lbf/in2] [.984] DIA straight keyed shaft, unloading valve 33 206.8-213.7 bar key included setting [3000-3100 lbf/in2] 10,11 Main ports AU End ports; tube ports per 17,18 Flow comp. setting 00 No flow compensator setting location and size SAE J514, suction 1.625-12 or unload VLV 11 9.65-12.41 bar [140-180 lbf/in2] UN-2B, pressure – 1.0625-12 standby 24 22.75-25.51 bar [330-370 UN-2B SAE lbf/in2] AV End ports; tube ports per 19,20 Secondary 00 No secondary compensator ISO 6149-1, suction M42 x 2, compensator setting setting pressure – M27 x 2 04 186.2-193.1 bar [2700-2800 12 Drain port size 6 M18 metric O-ring port – top (D1) lbf/in2] 7 M18 metric O-ring port– 21 Control special 0 No special features bottom(D2) features A Bleed down orifice – 8 M18 mertic O-ring port – shaft up B External manual stroke B .750-16 UNF-2B SAE O-ring adjustment port – top (D1) 22 Maximum 1 Standard displacement C .750-16 UNF-2B SAE O-ring displacement option 2 Adjustable maximum displace- port – bottom (D2) ment (set at maximum) D .750-16 UNF-2B SAE O-ring port – shaft up

Note: Consult an Eaton representative for additional settings

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 31 Model Number System PVQ25

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 P V Q2 5 A R 1 1 A A 1 0 B 1 1 2 4 0 0 A 2 0 0 1 A P C 9 0 1

Nos Feature Code Description 23,24 Auxiliary mounting 00 No auxiliary mounting or and output shaft output shaft 25 Shaft seals 0 No shaft seal 1 Standard shaft seal (nitrile) Vitron option 3 Flurocarbon 4 HNBR shaft seal luster glycol fluids 26,27 Special features AP Cast iron housing and industrial timing 28,29 Paint 00 No paint CD Blue primer 30 Customer and unit 0 STD – mark assembly identification Number and build data Code on plate 31 Design code A First

Note: Consult an Eaton representative for additional settings

RATINGS Model Maximum Geometric Rated Maximum Input Power at Max. Approx. Number Displacement Speed Pressure Pressure and Rated Speed Weight System cm3/r (in3/r) r/min bar (psi) kW (hp) kg (lb) PVQ25 25,2 (1.54) 1800 210 (3000) 16 (24) 14 (31) Pressure Limits: Case pressure – 0,35 bar (5 psig) maximum Inlet pressure – 0,2 bar (5 in. Hg) vacuum to 2 bar (30 psig)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 32 Controls

“G” Option “J” Option “H” Option Standard load-sensing and pres- Pressure Compensator Remote Control Pressure Load Sensing and Pressure sure limiting control with 11 bar Controls Compensator Limiter Compensator Control differential pressure (standard factory setting). Includes bleed- The pressure compensator con- Exactly the same as the pres- This compensator provides down orifice to exhaust load- trol automatically adjusts pump sure compensation option, load-sensing control under all sense signal for low-pressure delivery to maintain except the machine operator is pressure conditions up to the standby condition. volume requirements of the sys- able to change the compensator desired maximum. It automati- tem at a preselected operating setting through the use of a cally adjusts pump flow in Other Standard Load pressure. Maximum pump deliv- remote pilot relief valve, such as response to a remote pressure Sense Options: ery is maintained to ap- Eaton C-175. signal and maintains outlet pres- proximately 75 psi (PVQ025) sure at a level slightly above load 1. Bleed-down orifice plugged. below the pressure setting “C” Option pressure. The integral 2. Factory differential pressure before being reduced. The pres- pressure limiter overrides the setting of 24 bar. sure compensator control Electric Dual Range Pressure load-sensing control, reducing operates on one side of center Compensator Control pump displacement as the and has an adjustment range The dual range pressure com- preset maximum operating pres- as designated in the model num- pensator control automatically sure is reached. bering system. adjusts pump delivery to main- Standard load-sense differential tain volume requirements of the pressure settings, by control Pressure Compensator Control system at either of two pre- type, follow. See model number with Adjustable Maximum selected operating pressures. system for setting range. Displacement Stop Maximum pump delivery is The adjustable maximum stop maintained to approximately pressure control enables the 75 psi (PVQ025) below either maximum pump delivery to be pressure control setting before externally adjusted from 25% to being reduced. 100% while maintaining all of Control type and pressure the standard features of a pres- range are designated in the sure compensated pump. To model number system. assist initial priming, manual Note: Graphic symbols shown with external adjustment control setting must valve(s) and cylinder to illustrate typical be at least 40% of maximum usage. flow position.

“G” Option “J” Option “H” Option “C” Option

(†orifice open) (†orifice plugged)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 33 PVQ25 Performance Curves Performance at 1800 r/min Oil type: SAE 10W Oil temp: 50° C (120° F) Inlet pressure: 0 psi

100% Volumetric efficiency 90% kW (hp) 80% Overall efficiency 16,8 (22.5)

70% 14,9 (20.0) Efficiency 60% 13,0 (17.5) Input power 50% 11,2 (15.0)

9,3 (12.5) l/min (USgpm) Delivery 47,3 (12.5) 7,5 (10.0) Input power 37,9 (10.0) 5,6 (7.5)

Delivery Input power pump compensated 28,4 (7.5) 3,7 (5.0)

1,9 (2.5)

0 0 35 70 100 140 175 210 (500) (1000) (1500) (2000) (2500) (3000) Outlet pressure – bar (psi)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 34 PVQ25 Operating Data Sound Data Temperature: 50°C (120°F) Test Fluid: URSA-ED (10W) Inlet Pressure: Atmospheric (0 psig)

SOUND DATA Sound Level dB(A)* Speed Pressure Full r/min bar (psi) Stroke Cutoff 1000 35 (500) 56.5 54.9 70 (1000) 57.7 58.3 100 (1500) 58.6 60.0 140 (2000) 59.5 61.3 175 (2500) 60.9 62.0 210 (3000) 66.6 63.1 1200 35 (500) 60.9 56.9 70 (1000) 62.4 60.1 100 (1500) 63.1 62.3 140 (2000) 63.3 63.6 175 (2500) 63.8 64.5 210 (3000) 63.8 65.5 1500 35 (500) 61.9 57.7 70 (1000) 63.5 61.9 100 (1500) 64.2 62.7 140 (2000) 65.3 63.3 175 (2500) 65.1 64.7 210 (3000) 65.9 65.3 1800 35 (500) 64.0 59.0 70 (1000) 65.2 62.0 100 (1500) 66.0 63.4 140 (2000) 67.1 64.4 175 (2500) 67.5 65.7 210 (3000) 67.4 66.6 *Sound pressure data equivalent to NFPA Standard.

Response Data Control Type On stroke Off stroke Pressure compensator 0.030 sec. 0.012 sec. Yoke response recorded at rated Load sense compensator 0.040 sec. 0.012 sec. speed and pressure, 0 psi inlet, 82°C (180°F), SAE 10W oil. Pressure rise was 6900 bar (100,000 psi) per second.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 35 Installation Drawings

PVQ25 with Pressure Compensator Control

Note: Ports are reversed for Outlet port "B" (see note) 1.0625-12 UN-2B thd. R.H. rotation L.H. rotation 196,6 (7.74) SAE O-ring boss connection .750 O.D. tubing (Shown for R.H. rotation) 25,0 167,5 (0.98) (6.59) 44,0 44,0 14,53 9.4 (1.73) (1.73) Drain port "D2" 14,0 R (0.37) 14,15 2 places .750-16 UNF-2B thd. (0.572) (0.55 R) 14,0 0,8 max. R 47,0 SAE O-ring boss (0.557) (0.03) (0.55) (1.85) connection .500 O.D. tubing 73,0 70,0 60,0 56,0 (2.87) (2.76) 101,60 30 (2.36) 2 places 140,0 101.55 ( 2.20) (5.51) 146,0 51,5 (4.000) 28,4 52,0 70,1 (5.75) (2.03) (3.998) 83,1 ( 1.12) (2.05) (2.76) 73,4 (3.27) (2.89) 1.5 x 45 (0.06) 120,6 162,5 77,0 30,0 (4.75) #2 shaft (6.40) (1.18) (3.03) 19,5 R 19,0 114,1 (0.77 R) 186,1 (4.49) 154,0 (0.75) (7.33) 33,3 (6.06) (1.31) Compensator position for R.H. rotation 41,1 (Reverse for L.H. rotation) (1.62) Inlet port "A" (see note) 1.625-12 UN-2B thd. SAE O-ring boss connection 1.250 O.D. tubing (Shown for R.H. rotation) 29,5 (1.16) Construction plugs Do not remove 85,1 (3.35) 27,0 (1.06) 170,2 (6.70)

Alternate drain port "D1" .750-16 UNF-2B thd. 153,5 SAE O-ring connection (6.04) .500 O.D. tubing

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 36 Shaft Options

No. 1 Shaft No. 10 Mounting and Input Shaft SAE “B” Straight keyed (Flange and shaft end ISO 3019/21000A2HW-E25N)

22,225 6,375 22,200 6,350 x 31,75 lg. key (0.8750) (0.251) (1.250) 8,00 (0.8740) (0.250) 7,96 25,12 58,6 (0.315) (2.31) 28,01 (0.314) 24,87 27,71 Square key (0.989) (1.103) (0.979) (1.091) 100 99,95 D (3.937) (3.935) #1 shaft 25,006 14,25 1.5 x 45 24,994 D 42,0 (0.56) (0.06) 50.8 (0.9845) (1.65) (2.00) (0.9840) 10,5 (0.413) 9,25 70,00 (0.364) (2.76) 140,00 (5.51)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 37 Controls

Load Sensing with Pressure of pump mtg. flg. Limiter Load sensing comp. control 167,39 port location for R.H. (6.59) rotation .4375-20 UNF-2B 190,75 boss connection (7.51)

Load sensing control port 19,05 location for L.H. rotation (0.75) 28,45 (1.12) Max.

Compensator adj. knob. 28,45D (1.12) Do not back out adj. knob beyond 28,4 (1.12) dim. shown while pump is operating.

Remote Compensator

Adjustment 45,1 (1.775) 1. Turn pressure control (such as C-175) CCW to minimum setting. 2. Turn compensator adjust- ment plug to desired mini- mum pressure (17 bar, 250 psi or higher). .4375-20 UNF-2B Do not operate pump 3. Full pressure range can now thread for "CG" with this port plugged. be obtained with pressure control models. Connect to pressure control. control, such as Caution: Effective compensator pressure C-175. SAE O-ring will be compensator control setting boss connection (17-69 bar, 250-1000 psig) plus remote relief .250 O.D. tubing valve setting.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 38 Controls

Pressure Compensator Control with 52,0 72,6 (2.05) Adjustable Max. (2.86) 90,1 28,4 (3.55) Displacement (1.12) Stop Locknut 11,2 (0.44) across flats Adjustment 63,8 28,4 Adjusting screw (2.51) (1.12) 23,8 (0.90) across flats Loosen locknut on adjusting rod. Turn adjusting rod clockwise (CW) to decrease maximum 11,0 123,8 30,0 Max. Control position for pump delivery or counterclock- (4.87) (1.18) (0.43) wise (CCW) to increase maxi- Maximum stop right hand rotation mum pump delivery until adjusting rod desired setting is obtained. (Approx. 2.22 cc/rev Secure this setting by tightening change per turn) locknut. 252,1 220,2 (9.93) 196,2 (8.67) (7.72) Control position for left hand rotation Dimensions to flange face

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 39 Controls Electric Dual Range Pressure Compensator Control

Adjustment 1. With the directional valve Dimension from de-energized, loosen locknut flange face “5” and turn the adjusting screw “4” to the desired first stage pressure setting, then tighten locknut “5.” 2. With solenoid de-energized, turn adjusting spool “1” counterclockwise (CCW) until nut “3” is bottomed in adjusting screw slot. (Second stage setting is now equal to 312,1 1. Adjusting spool — sets (12.29) first stage pressure setting.) second stage pressure Turn adjusting spool clock- wise (CW) to desired second stage pressure requirements. 2. Locknut — 17,3 (0.68) One complete turn of across flats adjusting spool equals ap- proximately 41 bar (600 psi). 3. Locknut — must be Energize solenoid and check contained within slot of pressure setting. De-energize adjusting screw as shown solenoid and re-adjust if nec- 4. Adjusting screw 25,4 essary. Secure this setting by (1.00) across flats — sets tightening locknut “2.” first stage pressure 5. Locknut — 31,7 (1.25) 126,6 186,6 across flats (4.98) (7.35)

52,0 (2.05)

Dual range pressure Position for compensator position R.H. models

Electrical conduit conn.1 /2 NPTF thd.

Inrush amps Solenoid Data Solenoid current (R.M.S.) Holding amps (110V AC 50 Hz 115/120V AC 60 Hz – .54 110V AC 50 Hz 2.0 .64* and 115/120V AC *Maximum peak inrush amps approximately 1.4 x R.M.S. value shown. 60 Hz) Refer to catalog GB-C-2015B for additional solenoid valve data.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 40 Controls Electric Dual Range Pressure Compensator with Maximum Displacement Stop

Maximum Flow Adjustment Dimension from With the system pressure below flange face both compensator settings, loosen maximum stop adjusting screw locknut and adjust screw to desired flow position (turning screw clockwise decreases flow and turning screw counterclock- 196,2 wise increases flow). To lock (7.72) Position for screw in position, tighten lock- L.H. models nut. To assist initial priming, adjust control setting to at least 40% of maximum flow position.

Compensator Control 25,1 1. With the directional valve (0.99) de-energized, loosen locknut 30,0 (1.18) “5” and turn the adjusting 52,3 Electrical conduit screw “4” to the desired first (2.06) Locknut 1– 1,2 (0.44) across flats connection 1/2 NPTF thd. stage pressure setting, then Minimum delivery Maximum stop (adjusting screw) tighten locknut “5.” position (flush with Maximum stop nut). Do not adjust .250-20 UNC thd. adjusting rod 2. With directional valve below flush. Maximum delivery position (Approx. 2.22 cc/rev de-energized, turn adjusting change per turn) spool “1” counterclockwise until nut “3” is bottomed in adjusting screw slot. (Second stage setting is now equal to first stage pressure setting.) Turn adjusting spool 1. Adjusting spool — sets 213,4 clockwise to desired second second stage pressure (8.40) stage pressure require- ments. One complete turn of adjusting spool equals approximately 41 bar (600 psi). Energize solenoid and 2. Locknut — 17,3 (0.68) check pressure setting. across flats 93,5 De-energize solenoid and re- (3.68) adjust if necessary. Secure 3. Locknut — must be this setting by tightening contained within slot of locknut “2.” adjusting screw as shown 4. Adjusting screw 25,4 (1.00) across flats — sets first stage pressure 5. Locknut — 31,7 (1.25) across flats 136,3 196,3 (5.37) (7.73)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 41 Controls Unloading Valve Control – “E” Option

With the unloading valve control Adjustment range the variable pump will unload at PVQ25 100-210 bar (1500- a preset pressure. The pump will 3000 psi) maintain this no flow, low pres- Unload valve sure (approximately 14 bar [200 Cut-in pressure is 85% of control port psi]) standby condition, until sys- unloading pressure, minimum. tem pressure drops to about To l o a d 85% of the preset unloading Setting Pressures pressure. The pump will then 1. Back out accumulator un- Inlet Check Valve return on stroke and provide full loading pressure adjustment flow until the preset unloading screw to below desired pressure is reached again. unloading pressure. Outlet With this control, an efficient 2. Adjust desired standby pres- accumulator charging circuit is sure. obtained. The pump will provide Drain full flow to fill the accumulator 3. Set accumulator pressure by until the maximum charging screwing in the accumulator pressure is reached. The pump unloading adjustment screw. then goes to a standby condition Accumulator recharge (cut-in) until the accumulator pressure pressure is a function of the maximum accumulator pres- 196,6 drops to 85% of the desired (7.74) maximum. The accumulator is sure and is not adjustable. 167,5 then recharged as the cycle 4. Check pressure settings and (6.59) starts over again. re-adjust if necessary. A separate right angle check valve must be provided to main- tain the accumulator hydraulic charge and prevent back flow when the pump is unloaded. The check valve’s internal leakage 41,1 must not exceed five drops per (1.62) minute. The control port must be connected to system pressure, downstream of the check valve. 162,5 (6.40) 272,8 (10.74)

Control Port .4375-20 Accumulator unloading UNF-2B thd. SAE O-ring boss pressure adjustment connection .25 OD tubing

Standby pressure adjustment

52,0 (2.05)

145,5 (5.95)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 42 Model Number System PVQ40 and PVQ45

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 P V Q4 0 A R 1 1 A A 1 0 B 1 1 2 4 0 0 A 1 A A 1 A F C D 0 1

Nos Feature Code Description Nos Feature Code Description 1,2 Code title PV Open circuit piston pump 12 Drain port size 1 .875-14 UNF-2B SAE O-ring port–top (D1) 3,4,5,6Displacement Q40A 41.0cm3/r [2.50 in3/r] and location 2 .875-14 UNF-2B SAE O-ring port – Q45A 45.1cm3/4 [2.75 in3/r] bottom (D2) 3 .875-14 UNF-2B SAE O-ring port – 7 Input shaft L Left-hand rotation (CCW) shaft up rotation R Right-hand rotation (CW) 6 M18 X 1.5 metric O-ring port – top (D1) 8,9 Front mounting 01 2 Bolt B (SAE J744-101-2) with 7 M18 X 1.5 metric O-ring port – bottom (D2) and input shaft 22.2 [.88] DIA straight key shaft 8 M18 X 1.5 metric O-ring port – shaft up (SAE J744-22-1) (key included) 13 Diagnostic 0 No diagnostic pressure port 02 2 Bolt B-B (SAE J744-101-2) with 25.4 pressure port 1 .4375-20 UNF-2B SAE O-ring port – [1.00] DIA straight key shaft plugged (SAE J744-25-1) (key included) 2 M14 X 1.5 metric O-ring port – plugged 05 2 Bolt B-B (SAE J744-101-2) with 13T 16/32DP 41.1 [1.62] long splined shaft 14 Controller type C Electric dual range pressure compensator 08 2 Bolt B-B (SAE J744-101-2) with 15T with directional control valve 16/32DP splined shaft E Unloading valve (accumulator circuits) 09 2 Bolt B (SAE J744-101-2) with 26T G Adjustable pressure compensator 32/64DP splined shaft H Adjustable pressure and flow compensator 10 Shaft-2 Bolt VDMA A with25.0 [.984] J Adjustable hydraulic remote control DIA straight keyed shaft, key included pressure compensator 2 10,11 Main ports AA Side ports; tube ports per SAE J514, 15,16 Pressure comp./ 07 65.5-72.4 bar [950-1050 lbf/in ] unloading valve 18 182.7-189.6 bar [2650-2750 lbf/in2] location and size suction – 1.875-12 UN-2B, pressure – 2 1.3125-12 UN-2B 33 206.8-213.7 bar [3000-3100 lbf/in ] AB End ports; tube ports per SAE J514, 17,18 Flow comp. setting 00 No flow compensator setting suction – 1.875-12 UN-2B, pressure – or unload valve 11 9.65-12.41 bar [140-180 lbf/in2] 1.3125-12 UN-2B standby 14 12.41-15.17 bar [180-220 lbf/in2] AC Side ports; SAE J518 flange, suction – 24 22.75-25.51 bar [330-370 lbf/in2] 1.500 SAE 4-bolt split flange port (code 19,20 Secondary 00 No secondary compensator setting 61); pressure – 1.000 SAE 4-bolt split comp. setting 04 186.2-193.1 bar [2700-2800 lbf/in2] flange port (code 61) AD End ports; SAE J518 flange, suction – 21 Control special 0 No special features 1.500 SAE 4-bolt split flange port (code features A Bleed down orifice 61); pressure – 1.000 SAE 4-bolt split B External manual stroke adjustment flange port (code 61) 22 Maximum 1 Standard displacement AE Side ports; ISO 6149-1 tube, suction – displacement 2 Adjustable maximum displacement M48 X 2, pressure – M33 X 2 option (set at maximum) AF End ports; ISO 6149-1 tube, suction – M48 X 2, pressure – M33 X2 AS End ports; ISO 6162 flange, suction – 1.500 SAE 4-bolt split flange port with M12 X 1.75 threads; pressure – 1.000 SAE 4-bolt split flange port with M10 X 1.5 threads

Note: Consult an Eaton representative for additional settings

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 43 Model Number System PVQ40 and PVQ45

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 P V Q4 0 A R 1 1 A A 1 0 B 1 1 2 4 0 0 A 1 A A 1 A F C D 0 1

Nos Feature Code Description 23,24 Auxiliary mounting 00 No auxiliary mounting or output shaft 25 Shaft seals 0 No shaft seal output shaft AA 2 Bolt A (SAE J744-82-2) w/ 9T 1 Standard shaft seal (fluorocarbon) 16/32DP external splined shaft 8 HNBR shaft seal (water glycol) AB 2 Bolt A (SAE J744-82-2) w/ 11T 26,27 Special features AP Cast iron housing and industrial timing 16/32DP external splined shaft AC 2 Bolt B (SAE J744-101-2) w/ 13T 28,29 Paint 00 No paint 16/32 DP internal splined coupling CD Blue primer AD 2 Bolt B (SAE J744-101-2) w/ 15T 30 Customer and unit 0 STD – mark assembly number, 16/32DP internal splined coupling full model code and build date code AE 2 Bolt B (SAE J744-101-2) w/ 26T on plate 32/64DP external splined shaft AH 2 Bolt A (SAE J744-82-2) w/ 9T 31 Design code A First design 16/32DP internal splined coupling AJ 2 Bolt A (SAE J744-82-2) w/ 11T 16/32DP internal splined coupling AK 2 Bolt B (SAE J744-101-2) w/ 26T 32/64DP internal splined coupling

Note: Consult an Eaton representative for additional settings

RATINGS Model Maximum Geometric Rated Maximum Input Power at Max. Approx. Number Displacement Speed Pressure Pressure and Rated Speed Weight System cm3/r (in3/r) r/min bar (psi) kW (hp) kg (lb) PVQ40 41,5 (2.500) 1800 210 (3000) 27,6 (37) 20,6 (45.4) PVQ45 45,1 (2.750) 1800 186 (2700) 28,3 (38) 20,6 (45.4) Pressure Limits: Inlet pressure – 0,2 bar (5 in. Hg) vacuum to 2 bar (30 psig) Case pressure – 0,35 bar (5 in. Hg) maximum Note: Integral relief valve limits case pressure peaks to 0,7 bar (10 psi) higher than inlet pressure to protect pump. Flow from valve is returned directly to pump inlet. Use of case drain line required to limit steady-state case pressure.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 44 Controls

“G” Option “J” Option “H” Option Standard load-sensing and pres- Pressure Compensator Remote Control Pressure Load Sensing and Pressure sure limiting control with 11 bar Controls Compensator Limiter Compensator Control differential pressure (standard factory setting). Includes bleed- This control automatically varies Exactly the same as the “C” This compensator provides load- down orifice to exhaust load- pump displacement to meet the (pressure compensation option) sensing control under all pres- sense signal for low-pressure system flow demand for a con- except the machine operator is sure conditions up to the standby condition. stant system pressure. able to change the compensator desired maximum. It automati- Displacement starts to reduce to setting through the use of a cally adjusts pump flow in Other Standard Load Sense zero within 14 bar (200 psi) of remote pilot relief valve. response to a remote pressure Options: the compensator setting. Power signal and maintains outlet pres- draw-off is minimized, therefore, “C” Option sure at a level slightly above load 1. Bleed-down orifice plugged. system relief valves should not pressure. The integral pressure Electric Dual Range Pressure 2. Factory differential pressure be required. limiter overrides the load-sens- setting of 24 bar. Compensator Control ing control, reducing pump dis- Pressure Compensator Control The dual range pressure com- placement as the preset maxi- with Adjustable Maximum pensator control automatically mum operating pressure is Displacement Stop adjusts pump delivery to main- reached. tain volume requirements of the The adjustable maximum stop Standard load-sense differential system at either of two prese- pressure settings, by control pressure control enables the lected operating pressures. maximum pump delivery to be type, follow. See model number externally adjusted from 25% to Maximum pump delivery is system for setting range. 100% while maintaining all of maintained to approximately the standard features of a pres- 3,4 bar (50 psi) below either sure compensated pump. To pressure control setting before assist initial priming, manual being reduced. adjustment control setting must Control type and pressure range be at least 40% of maximum are designated in the model flow position. number system. Note: Graphic symbols shown with external valve(s) and cylinder to illustrate typical usage.

“G” Option “J” Option “C” Option “H” Option

(†orifice open) (†orifice plugged)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 45 Performance Curves PVQ40 Oil type: SAE 10W Oil temperature: 82°C (180°F) Inlet: 0 psi

Note: To obtain full flow 100% operation of pump, pres- 210 bar (3000 psi) sure compensator setting 140 bar (2000 psi) must be 14 bar (200 psi) above desired operating 80% 70 bar (1000 psi) pressure. Full flow curves 35 bar (500 psi) were obtained with com- pensator settings 14 bar 60% (200 psi) above 210 bar (3000 psi) max. rated pres-

sure. Volumetric efficiency 40%

100% 140 bar (2000 psi) 70 bar (1000 psi) 80% 35 bar (500 psi) 210 bar (3000 psi) 60% Overall efficiency 40% USgpm l/min 76 20

57 15

38 10 35 bar (500 psi) Delivery 70 bar (1000 psi) Delivery 19 140 bar (2000 psi) 5 210 bar (3000 psi)

0 0

kW hp 45 60

45 30 30 210 bar (3000 psi) 15 140 bar (2000 psi) Input power 15 Input power 70 bar (1000 psi) 35 bar (500 psi) 0 0 500 1000 1500 2000 Speed r/min

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 46 Model Series PVQ45 Oil type: SAE 10W Oil temperature: 82°C (180°F) Inlet: 0 psi

Note: To obtain full flow 100% operation of pump, pres- 140 bar (2000 psi) sure compensator setting 70 bar (1000 psi) must be 14 bar (200 psi) above desired operating 80% 35 bar (500 psi) pressure. Full flow curves 186 bar (2700 psi) were obtained with com- pensator settings 14 bar 60% (200 psi) above 186 bar (2700 psi) max. rated pressure. Volumetric efficiency 40%

100%

35 bar (500 psi) 80% 70 bar (1000 psi) 140 bar (2000 psi) 186 bar (2700 psi)

Overall efficiency 60% USgpm l/min 95 25

76 20

57 15

35 bar (500 psi) Delivery 38 70 bar (1000 psi) 10 Delivery 140 bar (2000 psi) 186 bar (2700 psi) 19 5

0 0

kW hp 45 60

45 30 30 186 bar (2700 psi) 15 140 bar (2000 psi) Input power 15 Input power 70 bar (1000 psi) 35 bar (500 psi) 0 0 500 1000 1500 2000 Speed r/min

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 47 Operating Data PVQ40 and PVQ45 Sound Data Temperature: 50°C (120°F) Test Fluid: URSA-ED (10W) Inlet Pressure: Atmospheric (0 psig)

SOUND DATA Sound Level dB(A)* Speed Pressure Full r/min bar (psi) Stroke Cutoff 1000 35 (500) 60 58 70 (1000) 61 61 140 (2000) 63 65 210 (3000)* 65 65 1200 35 (500) 61 60 70 (1000) 62 62 140 (2000) 65 65 210 (3000)* 66 68 1500 35 (500) 65 61 70 (1000) 67 64 140 (2000) 68 67 210 (3000)* 68 69 1800 35 (500) 68 60 70 (1000) 69 65 140 (2000) 69 68 210 (3000)* 71 70 **PVQ40 at 210 bar (3000 psi) and PVQ45 at 186 bar (2700 psi) **Sound pressure data equivalent to NFPA Standard.

Response Data Control Type On Stroke Off Stroke Pressure compensator 0.050 sec. 0.020 sec. Yoke response recorded at rated Load sense compensator 0.040 sec. 0.010 sec. speed and pressure, 0 psi inlet, 82°C (180°F), SAE 10W oil. Pressure rise was 6900 bar (100,000 psi) per second.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 48 Controls Side Port Controls, No. 2 Mounting and Input Shaft Millimeters (inches)

Drain port "D1" .875-14 UNF-2B thd. SAE Outlet port "B" see note. O-ring boss connection .625 O.D. tubing 1.3125-12 UN-2B thd. SAE 191,00 O-ring boss connection (7.52) 1.000 O.D. tubing. Shown 41,56 for R.H. rotation. (1.64) Construction plug. Do not remove. 95,25 97,28 (3.75) (3.83) 50,04 194,56 (1.97) 190,5 (7.66) (7.50) Note: Ports are reversed for L.H. rotation 25,37 (0.999) 25,4 25,35 (0.998) (1.00)

14,22 25,45 Max. (0.56) (1.12) 176,28 (6.94) Caution – While pump is operating do not back compensator Inlet port "A" see note. adjustment screw out 1.875–12 UN–2B thd. SAE beyond dimension shown. O-ring boss connection Plug shown for industrial 1.500 O.D. tubing. Shown models. for R.H. rotation Compensator position for L.H. rotation 6,35 (0.250) x 31.75 (1.250) Lg. key Compensator position R.H. 6,38 (0.251) for R.H. rotation 118,11 58,67 (4.65) Rotation (2.31) 211,07 173,74 (6.84) 34,04 28,22 (8.31) 86,87 (1.11) 1 9,53 (3.42) (1.34) 120,65 (.375) 28,45 27,97 (1.12) 20,32 (0.80)R (4.75) (1.101) 56,90 (2.24) 93,2 84,84 (3.67) 101,6 63,5 (3.34) 55,63 (4.00) (2.50) (2.19) 101,5 (3.998) 63,5 12,7 (0.50) (2.50) 91,44 88,1 (3.60) Typ. (3.47) 14,15 184,91 (0.557) 50,8 (7.28) 98,30 73,03 (2.00) 52,83 14,53 (2.875) 218,19 (3.87) (2.08) (0.572) (8.59) 196,60 146,05 (7.74) (5.750) Alternate drain port "D2" Date of assembly .875-14 UNF-2B thd. SAE stamped on flange O-ring boss connection .625 O.D. tubing

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 49 Controls

173,74 Note: Ports are reversed Rear Ports Inlet port "A" see note. (6.84) 1.875-12 UN-2B thd. SAE 86,87 for L.H. rotation O-ring boss connection (3.42) 47,7 47,7 1.500 O.D. tubing. Shown (1.88) (1.88) for R.H. rotation

84,8 91,4 96,8 (3.34) (3.60) (3.81)

73,7 3 84,8 3,8 (3.34) (2.90) (0.15) 91,4 (0.12) (3.60) Outlet port "B" see note. 1.3125-12 UN-2B thd. SAE Alternate drain port "D2 " O-ring boss connection 221,2 .875-14 UNF-2B thd. SAE (8.71) 1.000 O.D. tubing. Shown O-ring boss connection for R.H. rotation .625 O.D. tubing No. 08 Mounting No. 05 Shaft and Input Shaft No. 1 Shaft: SAE “B” Straight Keyed SAE “B” Splined SAE “B-B” Splined

44,45 45,97 (1.75) 44,45 (1.81) 25.12 22,225 (1.75) (0.989) (0.8750) 6,375 24,87 22,200 33.3 38,1 (0.251) x 31,75 lg. key y (0.979) (0.8740) 6,350 (1.250) (1.31) (1.50) (0.250) 23,75 (0.935) 101,6 (4.00) 101,5 (3.99) 30 1.5 x 45 1,52 (0.06) (0.06) x 45 9,52 9,4 33,32 (0.375) (1.312) (0.37) 5,8 Spline: SAE "B" Involute,, 13T Spline: SAE " B-B" Involute, (0.23) 16/32 DP flat root side fit 15T, 16/32 DP flat root side fit No. 10 Mounting 10,50 (4.30) and Input Shaft 100 (3.937) 99,95 (3.935) 42,0 with VDMA (1.65) Sq. key Flange 8,00 (0.315) 7,96 (0.314) 11,27 (Flange and shaft end ISO (0.444) 3019/2-100A2HW-E25N)

28,01 (1.103) 25,006 (0.9845) 27,71 (1.091) 24,994 (0.9840)

9,25 (0.364) 70 (2.75) 140,0 (5.51)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 50 Controls

Pressure Compensator Remote with Load Sensing Control

Load sensing comp. control 215,90 port location for R.H. rotation (8.50) .4375-20 UNF-2B thd. SAE 211,32 O-ring boss connection .250 (8.32) 239,27 O.D. tubing (9.42)

6,60 22,35 63,5 (2.6) (0.88) (0.250)

Load sensing control 118,88 131,57 port location for L.H. 50,8 (4.68) Comp. control (5.18) rotation (2.00) 74,68 port for L.H. 28,45 10,92 79,25 rotation (2.94) (0.43) (3.12) 19,05 (1.12) 28,45 (0.75) (1.12) Max.

55,63 55,63 (2.19) (2.19) Compensator adj. knob. Do not back out adj. knob beyond 28,45 (1.12) dimension shown while pump is operating. Comp. control port location for R.H. rotation .4375-20 UNF-2B thd. SAE O-ring boss connection .250 O.D. tubing

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 51 Controls Pressure Compensator Control with Adjustable Maximum Displacement Stop

Adjustment Loosen locknut on adjusting rod. Turn adjusting rod clockwise (CW) to decrease maximum pump delivery or counter- clockwise (CCW) to increase maximum pump delivery until desired setting is obtained. Secure this setting by tightening locknut. To assist initial priming, manual adjustment control set- ting must be at least 40% of maximum flow position. This control enables the maxi- 219,4 mum pump delivery to be (8.64) externally adjusted from 25% 279,1 to 100% while maintaining all (10.99) of the standard features of a pressure compensated pump. Note: Not available with thru-drive models. Maximum stop adjusting screw .250-20 UNC thd. 13,9 (Approx. cc/rev 59,7 (0.59) change per turn: (2.35) PVQ40 – 3.22 Minimum delivery position PVQ45 – 3.55) (screw flush with nut) 34 Maximum delivery position (1.34)

28,4 127,7 28,4 23,87 across flats (1.12) (5.03) (0.94) (1.12) Max.

Compensator adj. knob. Do not back adj. knob beyond 28,4 (1.12) 97,2 dimension shown while (3.83) 55,6 pump is operating. (2.19)

Locknut 1 1,7 (0.44) across flats

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 52 Controls Electric Dual Range Pressure Compensator with Maximum Displacement Stop

See preceding page and following page for adjustment procedures.

279,1 (10.99) 2 lead wires from solenoid, approx. 152 mm (6.00 in) long with M3 (#6) 219,4 size terminals provided for (8.64) customer connection. Control position shown for L.H. rotation

15 (0.59) Max. Min. delivery delivery Control position position shown for R.H. position (screw flush with nut) 34 u rotation (1.34) 180,6 Solenoid Data 131,8 (7.11) (5.19) Max. stop adj. screw (110V AC 50 Hz (.250-20 UNC thd.) and 115/120V AC 73,41 (2.89) Electrical conduit 60 Hz) 17,53 connection (0.69) 1/2 NPT thread Inrush amps Holding Solenoid current (R.M.S.) amps 115/120V AC 60 Hz - 2.0 .54 Manual 110V AC 50 Hz .64* actuator *Maximum peak inrush amps approxi- 1. Adjusting spool — sets mately 1.4 x R.M.S. value shown. second stage pressure Refer to catalog GB-C-2015B for addi- Locknut 218,9 tional solenoid valve data. 11,2 (0.44) 195,1 (8.62) uNote: Any sliding spool valve, if across flats (7.68) held shifted under pressure for long 150,4 periods of time, may stick and not 2. Locknut — 17,3 (0.68) (5.92) spring return due to fluid residue for- across flats mation and, therefore, should be 3. Locknut — must be cycled periodically to prevent this 55,6 from happening. contained within slot of (2.19) adjusting screw as shown 4. Adjusting screw 25,4 (1.00) across flats — sets first stage pressure 5. Locknut — 31,7 (1.25) across flats

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 53 Controls Electric Dual Range Pressure Compensator Control

Adjustment 1. With the directional valve de- energized, loosen locknut “5” and turn the adjusting screw “4” to the desired first stage pressure setting, then tighten locknut “5.” 2. With solenoid de-energized, turn adjusting spool “1” counterclockwise (CCW) until nut “3” is bottomed in 214,6 adjusting screw slot. (Second (8.45) stage setting is now equal to 268 first stage pressure setting.) (10.55) Turn adjusting spool clock- wise (CW) to desired second 1. Adjusting spool – sets 312,7 stage pressure requirements. second stage pressure (12.31) One complete turn of adjust- 335,2 ing spool equals approximate- (13.2) ly 41 bar (600 psi). Energize solenoid and check pressure 2. Locknut – 17,3 (0.68) setting. across flats De-energize solenoid and re- Manual adjust if necessary. Secure 3. Locknut – must be actuator this setting by tightening contained within slot of locknut “2.” adjusting screw as shown Electrical conduit 4. Adjusting screw 25,4 connection (1.00) across flats – sets 1/2 NPT thread first stage pressure 5. Locknut – 31,7 (1.25) Solenoid Datau across flats (110V AC 50 Hz and 115/120V AC 122,2 190,2 60 Hz) Control position (4.81) 83 (7.49) shown for R.H. (3.27) rotation Inrush amps Holding Solenoid current (R.M.S.) amps 115/120V AC 60 Hz - .54 110V AC 50 Hz2.0 .64* 55,6 (2.19) *Maximum peak inrush amps approxi- mately 1.4 x R.M.S. value shown. Control position Refer to catalog GB-C-2015B for addi- shown for L.H. tional solenoid valve data. rotation uNote: Any sliding spool valve, if held shifted under pressure for long periods of time, may stick and not spring return due to fluid residue for- 2 lead wires from mation and, therefore, should be cycled periodically to prevent this solenoid, approx. 152 mm from happening. (6.00 in) long with M3 (#6) size terminals provided for customer connection.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 54 Controls Unloading Valve Control – “E” Option

With the unloading valve control Adjustment range the variable pump will unload at PVQ40 100-210 bar a preset pressure. The pump will (1500-3000 psi) maintain this no flow, low pres- PVQ45 100-186 bar Unload valve sure (approximately 14 bar [200 (1500-2700 psi) control port psi]) standby condition, until sys- tem pressure drops to about Cut-in pressure is 85% of To l o a d 85% of the preset unloading unloading pressure, minimum. pressure. The pump will then Inlet return on stroke and provide full Setting Pressures Check Valve flow until the preset unloading 1. Back out accumulator un- pressure is reached again. loading pressure adjustment With this control, an efficient screw to below desired Outlet accumulator charging circuit is unloading pressure. Drain obtained. The pump will provide 2. Adjust desired standby full flow to fill the accumulator pressure. until the maximum charging pressure is reached. The pump 3. Set accumulator pressure by then goes to a standby condition screwing in the accumulator until the accumulator pressure unloading adjustment screw. drops to 85% of the desired Accumulator recharge (cut-in) maximum. The accumulator is pressure is a function of the 219,4 then recharged as the cycle maximum accumulator pres- (8.64) starts over again. sure and is not adjustable. 184.9 A separate right angle check 4. Check pressure settings and (7.28) valve must be provided to main- re-adjust if necessary. tain the accumulator hydraulic charge and prevent back flow when the pump is unloaded. The check valve’s internal leakage must not exceed five drops per minute. The control port must be 91.4 connected to system pressure, (3.60) downstream of the check valve.

Standby pressure Control Port .4375-20 adjustment UNF-2B thd. SAE O-ring boss connection .25 OD tubing Accumulator unloading pressure adjustment 145,5 (5.95)

74,7 (2.94) 55,6 (2.19)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 55 Thru-drives PVQ40 and PVQ45 SAE “A”

28,22 (1.11) 6,35 (0.251) 27,97 6,30 (0.250) Sq. key 147,57 (1.10) (5.81) A (see table on next page)

25,37 31,75 Output spline – see (0.999) (1.25) thru-drive table on next 25,35 page 97,28 (0.998) (3.83) 25,4 (1.00) 194,56 82,55 87,38 (7.66) (3.253) (3.44) No. 2 shaft 50.8 Drain port "D1". .875-14 UNF-2B thd. (2.00) SAE O-ring boss connection .825 1,42 (0.056) O.D. tubing 22,61 1,32 (0.052) 58,67 151,13 (0.89) (2.31) (5.95) 12,7 12,7 (0.50) 191,26 (0.500) (7.53) 50,8 (2.00)

Load sensing control port Note: Ports are reversed .375-16 UNC-2B thd. .4375-20 UNF-2B thd. SAE for L.H. rotation. .88 deep – 4 places O-ring boss connection .250 Outlet port "B". 28,45 O.D. tubing Do not back out comp. (1.12) Inlet port "A". See note See note. 1.00 adjusting knob beyond Max. 1.50 diameter inlet. SAE diameter inlet. this dimension while J518 4-bolt flange. SAE J518 4-bolt pump is operating. Standard pressure series flange. Standard pressure series .500-13 UNC-2B thd. 95,25 52,37 45,97 84,84 1.06 deep – 4 places (3.75) (2.062) Outlet port 38,1 (1.81) (3.34) .375-16 UNC-2B 26,18 (1.50) thd. .72 deep – "B" face (1.031) 2 holes 84,84 23,75 (3.34) 101,6 (4.00) (0.935) 69,85 101,5 (3.99) (2.75) 73,6 1,52 (0.06) x 45 (2.90) 91,44 34,935 88,1 (3.60) 13,1 (1.375) (0.516) 14,48 (3.47) 9,4 (0.57) 17,86 26,2 (0.37) 35,7 (0.703) 53,09 (1.031) "A" flange 242,06 (1.406) (2.09) 105,43 (9.53) Alternate drain (4.19) port "D2" 91,95 91,95 (3.62) (3.62)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 56 Thru-drives PVQ40 and PVQ45 SAE “B”

191,0 Outlet port "B" see note. (7.52) 142,4 1.3125-12 UN-2B thd SAE O-ring (5.61) boss connection 1.00 O.D. tubing 41,6 A (see below) (1.64) 5,8 No. 4 shaft 98,5 (0.23) Modified (3.88) involute spline – SAE BB 197,3 107,2 (4.221) 107,1 (4.219) (7.77) 1,52 (0.06) x 45 101,7 (4.003) 101,6 (4.001) 1,45 (0.057) 23,75 Drain port 1.30 (0.051) (0.935) 38,10 12,7 (1.500) 176,3 (0.50) 45,9 (6.94) 57,2 (1.81) (2.25) Do not back out comp. adjusting knob beyond this dimension while pump is Note: Ports are reversed for L.H. rotation. operating. 28,45 (1.12) Load sensing control port Max. .4375-20 UNF-2B thd. SAE 25,4 O-ring boss connection (1.00) 9,7 .250 O.D. tubing No. 2 shaft (0.38) 120,65 (4.75) 6,35 x 31,75 lg. key 14,5 Inlet port "A" see note. 1.875-12 .500-13 (0.25) (1.250) (0.57) UN-2B thd. SAE O-ring boss UNC-2B th connection 1.500 O.D. tubing .88 deep – 2 holes 28,2 (1.110) 27,9 (1.100) 101,6 (4.00) 25,1 63,50 (0.999) (2.50)

50,8 (2.00) 73,03 146,05 56,7 254,8 (2.875) (2.31) (10.03) (5.750) 95,25 95,25 (3.75) (3.75) 98,30 (3.87) 196,6 (7.74)

Thru-drive Max. Torque Dimension A Thru-drive Shaft Spline Data Nm (in. lb.) mm (in.) Coupling Type Coupling ASA B5.15-1960 AA 9 teeth 16/32 DP 58 (517) 10,92 (0.43) 9T/9T 864224 Flat root side fit ANS B92.1-1970 AB 11 teeth 16/32 DP 118 (1050) 12,57 (0.495) 11T/11T 864325 Flat root side fit Special Eaton 24,89 (0.98) 26T/26T 627168 AE 26 teeth 32/64 DP 179 (1587) 10,92 (0.43) 26T/13T 864307 Flat root side fit 20,56 (0.81) 26T/15T 475134 Note: Coupling, screws, and washers must be ordered separately to mount rear pump. “A” O-ring (AS568-042) and “B” O-ring (AS568-155) are included with each thru-drive pump. Couplings for “B26” are step type for 13 and 15 tooth as shown.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 57 Thru-drives Shaft Torque Data PVQ40/45

THRU-DRIVE SHAFT TORQUE DATA Maximum Input Maximum Thru-drive Torque Total Torque Output Shaft Input Shaft Code Nm (lb. in.) Nm (lb. in.) 2 215 (1900) 5 208 (1850) 9T 58 (517) 8 337 (2987) 2 215 (1900) 5 208 (1850) 11T 123 (1100) 8 337 (2987) 2 215 (1900) 5 208 (1850) 26T 179 (1587) 8 337 (2987) Note: Both input and output limits must be met.

Typical Rear TYPICAL REAR PUMPS (WITH SHAFT CODES) FOR PVQ40/45 THRU-DRIVES Pumps (with Thru-drive shaft Typical Rear Pump Rear Pump Shaft Code Thru-drive Coupling PVQ10/13 3 Shaft Codes) PVB5/6 S124 suffix 9T 864224 for PVQ40/45 V10 11 Thru-drives V20 62 2 864307 PVE012 28 627168 3 864307 PVQ20/32 28 627168 3 864307 26T PVQ40/45 4 475134 28 627168 V2010 OR V2020 11 864307 20V 151 864307 2520V 166 475134 Note: 11T (not listed above) is intended for special application only.

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 58 Thru-drives PVQ40 and PVQ45 Pump Support Bracket

An optional support bracket should be used when a heavy second pump is mounted to a thru-drive PVQ40 or PVQ45. The support bracket (627179), two screws (199740), and two washers (427700) must be ordered separately. 171,45 (6.75) 11,68 147,83 (0.46) (5.820) 85,85 10,41 (0.410) 2 holes 85,85 (3.38) 10,29 (0.405) (3.38)

33,78 17,27 (1.33) R 12,85 (0.506) 2 holes 55,37 (0.68) 12,73 (0.501) 82,55 (2.18) (3.25)

19,05 (0.75) 19,05 19,05 (0.75) (0.75) 28,575 114,30 28,575 (1.125) (4.500) (1.125)

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 59 Application Data Fluid Cleanliness

Proper fluid condition is essen- Eaton publication 561 “Eaton levels in the system and are than those described. Other tial for long and satisfactory life Guide to Systemic Contamina- coded in the chart below. Fluids manufacturers will often recom- of hydraulic components and tion Control” available from your other than petroleum, severe mend levels above those speci- systems. Hydraulic fluid must local Eaton distributor or by con- service cycles, or temperature fied. Experience has shown, have the correct balance of tacting Eaton. Recommenda- extremes are cause for adjust- however, that life of any cleanliness, materials, and tions on filtration and the selec- ment of these cleanliness hydraulic component is short- additives for protection against tion of products to control fluid codes. See Eaton publication ened in fluids with higher clean- wear of components, elevated condition are included in 561. 561 for exact details. liness codes than those listed viscosity, and inclusion of air. Recommended cleanliness lev- Eaton products, as any com- below. These codes have been Essential information on the cor- els, using petroleum oil under ponents, will operate with proven to provide a long, trou- rect methods for treating common conditions, are based apparent satisfaction in fluids ble-free service life for the hydraulic fluid is included in on the highest fluid pressure with higher cleanliness codes products shown, regardless of the manufacturer.

System Pressure Level bar (psi) Product <70 (<1000) 70-210 (1000-3000) 210+ (3000+) Piston Pumps – Variable 18/16/14 17/15/13 16/14/12

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 60 Application Data

Hydraulic Fluids Fire Resistant Installation Ordering and Temperature Fluids and Start-up Procedure Ranges All pumps can be used with (Commissioning) Order pumps by the full model water glycol and polyol ester flu- designation. Pump displace- Use antiwear hydraulic oil, or ids. All pumps can be operated Before a pump is started, fill ment, mounting flange type, automotive type crankcase oil to 140 bar (2000 psi) with these the case through the uppermost direction of rotation, pump designations SC, SD, SE or SF fluids, except PVQ13 and PVQ32 drain port with hydraulic oil of configuration, shaft end type, per SAE J183FEB80. which are limited to the type to be used. The case seals, pressure adjustment Select a viscosity grade that 105 bar (1500 psi). Input speed drain line must be connected to range, and specific control will allow optimum viscosity, should not exceed 1800 r/min. the reservoir below oil level. functions are all specified in the between 40 cSt (180 SUS) and System temperature should not For multiple pump arrangements full model number system. 16 cSt (80 SUS), to be achieved exceed 54° C (130° F). Inlet vac- that include non-PVQ sections, Couplings, O-rings, capscrews within the optimum perfor- uum should not exceed the requirements of the non- and washers must be ordered mance envelope shown below. 101,6 millibar (3 in. Hg). For PVQ units must be considered. separately for all thru-drive more information, refer to Eaton For further information, see pumps. publication 579. Eaton data sheet B-920 or I-286-S.

Viscosity SUS cSt 2300 500 Extreme performance envelope

Typical SAE 10W Optimum performance viscosity grade oil envelope 250 54

70 13

–20 10 38 65 82 ˚C

–4 50 100 150 180 ˚F Temperature

EATON Vickers Q Series Piston Pumps Catalog V-PP-MC-0002-E December 2002 61 ODDZIAŁ GDAŃSK tel. /+48/ 55 625 51 21 fax /+48/ 55 625 51 22

ODDZIAŁ RUMIA CENTRALA ELBLĄG tel. /+48/ 58 679 34 15 fax /+48/ 55 625 51 25 ul. Rawska 19B 82-300 Elbląg ODDZIAŁ tel. /+48/ 32 787 52 88 tel. /+48/ 55 625 51 00 fax /+48/ 55 625 51 38 fax /+48/ 55 625 51 01 ODDZIAŁ OLSZTYN Dział Handlowy tel. /+48/ 89 532 01 05 fax /+48/ 89 715 21 42 tel. /+48/ 55 625 51 51 ODDZIAŁ WARSZAWA [email protected] tel. /+48/ 22 468 86 97 fax /+48/ 55 625 51 32

BIURO WE WROCŁAWIU tel. /+48/ 782 838 000 fax /+48/ 55 625 51 35

BIURO W KIELCACH tel. /+48/ 885 995 501 fax /+48/ 55 625 51 01

BIURO W KRAKOWIE tel. /+48/ 885 995 019 fax /+48/ 55 625 51 01

BIURO W OPOLU tel. /+48/ 885 995 011 fax /+48/ 55 625 51 01

BIURO W BYDGOSZCZY tel. /+48/ 790 222 771 fax /+48/ 55 625 51 01 www.hydropress.pl BIURO W BIAŁYMSTOKU tel. /+48/ 89 532 01 05 fax /+48/ 89 715 21 42

BIURO W ŁODZI tel. /+48/ 609 221 421 fax /+48/ 89 715 21 42