Candela, Lumen, Lux: a Brief Explanation
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Lecture 3: the Sensor
4.430 Daylighting Human Eye ‘HDR the old fashioned way’ (Niemasz) Massachusetts Institute of Technology ChriChristoph RstophReeiinhartnhart Department of Architecture 4.4.430 The430The SeSensnsoror Building Technology Program Happy Valentine’s Day Sun Shining on a Praline Box on February 14th at 9.30 AM in Boston. 1 Happy Valentine’s Day Falsecolor luminance map Light and Human Vision 2 Human Eye Outside view of a human eye Ophtalmogram of a human retina Retina has three types of photoreceptors: Cones, Rods and Ganglion Cells Day and Night Vision Photopic (DaytimeVision): The cones of the eye are of three different types representing the three primary colors, red, green and blue (>3 cd/m2). Scotopic (Night Vision): The rods are repsonsible for night and peripheral vision (< 0.001 cd/m2). Mesopic (Dim Light Vision): occurs when the light levels are low but one can still see color (between 0.001 and 3 cd/m2). 3 VisibleRange Daylighting Hanbook (Reinhart) The human eye can see across twelve orders of magnitude. We can adapt to about 10 orders of magnitude at a time via the iris. Larger ranges take time and require ‘neural adaptation’. Transition Spaces Outside Atrium Circulation Area Final destination 4 Luminous Response Curve of the Human Eye What is daylight? Daylight is the visible part of the electromagnetic spectrum that lies between 380 and 780 nm. UV blue green yellow orange red IR 380 450 500 550 600 650 700 750 wave length (nm) 5 Photometric Quantities Characterize how a space is perceived. Illuminance Luminous Flux Luminance Luminous Intensity Luminous Intensity [Candela] ~ 1 candela Courtesy of Matthew Bowden at www.digitallyrefreshing.com. -
Foot-Candles: Photometric Units
UPDATED EXTRACT FROM CREG JOURNAL. FILE: FOOT3-UP.DOC REV. 8. LAST SAVED: 01/02/01 15:14 PHOTOMETRICS Foot-Candles: Photometric Units More footnotes on optical topics. David Gibson describes the confusing range of photometric units. A discussion of photometric units may the ratio of luminous efficiency to luminous The non-SI unit mean spherical candle- seem out of place in an electronic journal but efficiency at the wavelength where the eye is power is the intensity of a source if its light engineers frequently have to use light sources most sensitive. Unfortunately, however, this output were spread evenly in all directions. It and detectors. The units of photometry are term can be confused with the term efficacy, is therefore equivalent to the flux [lm] ¸ 4p. some of the most confusing and least which is used to describe the efficiency at standardised of units. converting electrical to luminous power. Luminance Photometric units are not difficult to The candela measures the intensity of a understand, but can be a minefield to the Illumination, Luminous Emittance. point source. We also need to define the uninitiated since many non-SI units are still The illumination of a surface is the properties of an extended source. Each small in use, and there are subtle differences incident power flux density measured in element DS of a diffuse reflective surface will between quantities with similar names, such lumens per square metre. A formal definition scatter the incident flux DF and behave as if as illumination and luminance. would be along the lines of: if a flux DF is it were an infinitesimal point source. -
Light and Illumination
ChapterChapter 3333 -- LightLight andand IlluminationIllumination AAA PowerPointPowerPointPowerPoint PresentationPresentationPresentation bybyby PaulPaulPaul E.E.E. Tippens,Tippens,Tippens, ProfessorProfessorProfessor ofofof PhysicsPhysicsPhysics SouthernSouthernSouthern PolytechnicPolytechnicPolytechnic StateStateState UniversityUniversityUniversity © 2007 Objectives:Objectives: AfterAfter completingcompleting thisthis module,module, youyou shouldshould bebe ableable to:to: •• DefineDefine lightlight,, discussdiscuss itsits properties,properties, andand givegive thethe rangerange ofof wavelengthswavelengths forfor visiblevisible spectrum.spectrum. •• ApplyApply thethe relationshiprelationship betweenbetween frequenciesfrequencies andand wavelengthswavelengths forfor opticaloptical waves.waves. •• DefineDefine andand applyapply thethe conceptsconcepts ofof luminousluminous fluxflux,, luminousluminous intensityintensity,, andand illuminationillumination.. •• SolveSolve problemsproblems similarsimilar toto thosethose presentedpresented inin thisthis module.module. AA BeginningBeginning DefinitionDefinition AllAll objectsobjects areare emittingemitting andand absorbingabsorbing EMEM radiaradia-- tiontion.. ConsiderConsider aa pokerpoker placedplaced inin aa fire.fire. AsAs heatingheating occurs,occurs, thethe 1 emittedemitted EMEM waveswaves havehave 2 higherhigher energyenergy andand 3 eventuallyeventually becomebecome visible.visible. 4 FirstFirst redred .. .. .. thenthen white.white. LightLightLight maymaymay bebebe defineddefineddefined -
Illumination and Distance
PHYS 1400: Physical Science Laboratory Manual ILLUMINATION AND DISTANCE INTRODUCTION How bright is that light? You know, from experience, that a 100W light bulb is brighter than a 60W bulb. The wattage measures the energy used by the bulb, which depends on the bulb, not on where the person observing it is located. But you also know that how bright the light looks does depend on how far away it is. That 100W bulb is still emitting the same amount of energy every second, but if you are farther away from it, the energy is spread out over a greater area. You receive less energy, and perceive the light as less bright. But because the light energy is spread out over an area, it’s not a linear relationship. When you double the distance, the energy is spread out over four times as much area. If you triple the distance, the area is nine Twice the distance, ¼ as bright. Triple the distance? 11% as bright. times as great, meaning that you receive only 1/9 (or 11%) as much energy from the light source. To quantify the amount of light, we will use units called lux. The idea is simple: energy emitted per second (Watts), spread out over an area (square meters). However, a lux is not a W/m2! A lux is a lumen per m2. So, what is a lumen? Technically, it’s one candela emitted uniformly across a solid angle of 1 steradian. That’s not helping, is it? Examine the figure above. The source emits light (energy) in all directions simultaneously. -
LEP 2.4.04 Lambert's
R LEP Lambert’s law 2.4.04 Related topics Problems luminous flux, light quantity, light intensity, illuminance, lumi- 1. The luminous flux emitted reflected by a diffusely reflecting nance. surface is to be determined as a function of the angle of observation. Principle and task 2. Lambert’s law (cos-law) is to be verified using the graph of the measurement values. Visible light impinges on a diffusely reflecting surface. The luminance of this surface is determined as a function of the angle of observation. Set up and procedure The stand tube is introduced into the articulated radial holder, Equipment which is fitted with an angular scale, until it goes no further. The articulated radial holder is then attached to the tripod Housing for experiment lamp 08129.01 1 base, after which the tripod rods are clamped each with an Halogen lamp, 12 V/50 W 08129.06 1 edge facing upward. The luxmeter probe is attached to the Holder G 6.35 f. 50/100 W halo.lamp 08129.04 1 short support rod using the universal clamp in such a way that Double condenser, f 60 mm 08137.00 1 it points to the pivoting centre whilst being aligned with the Lens holder 08012.00 1 rod. The rest of the set up is shown in Fig. 1. The distances of Lens, mounted, f +200 mm 08024.01 1 the components from the pivot centre are shown in Fig. 2. Zinc sulfide screen 08450.00 1 Right angle clamp -PASS- 02040.55 4 On the luminous screen, the surface of which is directed per- Tripod base -PASS- 02002.55 1 pendicularly to the optical axis to start with, a circular surface B Barrel base -PASS- 02006.55 1 ( approx. -
Determination of Resistances for Brightness Compensation
www.osram-os.com Application Note No. AN041 Determination of resistances for brightness compensation Application Note Valid for: TOPLED® / Chip LED® / Multi Chip LED® TOPLED E1608® /Mini TOPLED® / PointLED® Advanced Power TOPLED® / FIREFLY® SIDELED® Abstract This application note describes the procedure for adjusting the brightness of light emitting diodes (LEDs) in applications by means of resistors. For better repeatability, the calculation of the required resistance values is shown by means of an example. Author: Hofman Markus / Haefner Norbert 2021-08-10 | Document No.: AN041 1 / 14 www.osram-os.com Table of contents A. Introduction ............................................................................................................ 2 B. Basic procedure ..................................................................................................... 2 C. Possible sources of errors ..................................................................................... 3 Temperature ...................................................................................................... 3 Forward voltage ................................................................................................. 4 D. Application example .............................................................................................. 4 E. Conclusion ........................................................................................................... 12 A. Introduction Due to manufacturing tolerances during production, LEDs cannot be produced -
2.1 Definition of the SI
CCPR/16-53 Modifications to the Draft of the ninth SI Brochure dated 16 September 2016 recommended by the CCPR to the CCU via the CCPR president Takashi Usuda, Wednesday 14 December 2016. The text in black is a selection of paragraphs from the brochure with the section title for indication. The sentences to be modified appear in red. 2.1 Definition of the SI Like for any value of a quantity, the value of a fundamental constant can be expressed as the product of a number and a unit as Q = {Q} [Q]. The definitions below specify the exact numerical value of each constant when its value is expressed in the corresponding SI unit. By fixing the exact numerical value the unit becomes defined, since the product of the numerical value {Q} and the unit [Q] has to equal the value Q of the constant, which is postulated to be invariant. The seven constants are chosen in such a way that any unit of the SI can be written either through a defining constant itself or through products or ratios of defining constants. The International System of Units, the SI, is the system of units in which the unperturbed ground state hyperfine splitting frequency of the caesium 133 atom Cs is 9 192 631 770 Hz, the speed of light in vacuum c is 299 792 458 m/s, the Planck constant h is 6.626 070 040 ×1034 J s, the elementary charge e is 1.602 176 620 8 ×1019 C, the Boltzmann constant k is 1.380 648 52 ×1023 J/K, 23 -1 the Avogadro constant NA is 6.022 140 857 ×10 mol , 12 the luminous efficacy of monochromatic radiation of frequency 540 ×10 hertz Kcd is 683 lm/W. -
Guide for the Use of the International System of Units (SI)
Guide for the Use of the International System of Units (SI) m kg s cd SI mol K A NIST Special Publication 811 2008 Edition Ambler Thompson and Barry N. Taylor NIST Special Publication 811 2008 Edition Guide for the Use of the International System of Units (SI) Ambler Thompson Technology Services and Barry N. Taylor Physics Laboratory National Institute of Standards and Technology Gaithersburg, MD 20899 (Supersedes NIST Special Publication 811, 1995 Edition, April 1995) March 2008 U.S. Department of Commerce Carlos M. Gutierrez, Secretary National Institute of Standards and Technology James M. Turner, Acting Director National Institute of Standards and Technology Special Publication 811, 2008 Edition (Supersedes NIST Special Publication 811, April 1995 Edition) Natl. Inst. Stand. Technol. Spec. Publ. 811, 2008 Ed., 85 pages (March 2008; 2nd printing November 2008) CODEN: NSPUE3 Note on 2nd printing: This 2nd printing dated November 2008 of NIST SP811 corrects a number of minor typographical errors present in the 1st printing dated March 2008. Guide for the Use of the International System of Units (SI) Preface The International System of Units, universally abbreviated SI (from the French Le Système International d’Unités), is the modern metric system of measurement. Long the dominant measurement system used in science, the SI is becoming the dominant measurement system used in international commerce. The Omnibus Trade and Competitiveness Act of August 1988 [Public Law (PL) 100-418] changed the name of the National Bureau of Standards (NBS) to the National Institute of Standards and Technology (NIST) and gave to NIST the added task of helping U.S. -
2019 Redefinition of SI Base Units
2019 redefinition of SI base units A redefinition of SI base units is scheduled to come into force on 20 May 2019.[1][2] The kilogram, ampere, kelvin, and mole will then be defined by setting exact numerical values for the Planck constant (h), the elementary electric charge (e), the Boltzmann constant (k), and the Avogadro constant (NA), respectively. The metre and candela are already defined by physical constants, subject to correction to their present definitions. The new definitions aim to improve the SI without changing the size of any units, thus ensuring continuity with existing measurements.[3][4] In November 2018, the 26th General Conference on Weights and Measures (CGPM) unanimously approved these changes,[5][6] which the International Committee for Weights and Measures (CIPM) had proposed earlier that year.[7]:23 The previous major change of the metric system was in 1960 when the International System of Units (SI) was formally published. The SI is a coherent system structured around seven base units whose definitions are unconstrained by that of any other unit and another twenty-two named units derived from these base units. The metre was redefined in terms of the wavelength of a spectral line of a The SI system after the 2019 redefinition: krypton-86 radiation,[Note 1] making it derivable from universal natural Dependence of base unit definitions onphysical constants with fixed numerical values and on other phenomena, but the kilogram remained defined in terms of a physical prototype, base units. leaving it the only artefact upon which the SI unit definitions depend. The metric system was originally conceived as a system of measurement that was derivable from unchanging phenomena,[8] but practical limitations necessitated the use of artefacts (the prototype metre and prototype kilogram) when the metric system was first introduced in France in 1799. -
Traffic and Road Sign Recognition
Traffic and Road Sign Recognition Hasan Fleyeh This thesis is submitted in fulfilment of the requirements of Napier University for the degree of Doctor of Philosophy July 2008 Abstract This thesis presents a system to recognise and classify road and traffic signs for the purpose of developing an inventory of them which could assist the highway engineers’ tasks of updating and maintaining them. It uses images taken by a camera from a moving vehicle. The system is based on three major stages: colour segmentation, recognition, and classification. Four colour segmentation algorithms are developed and tested. They are a shadow and highlight invariant, a dynamic threshold, a modification of de la Escalera’s algorithm and a Fuzzy colour segmentation algorithm. All algorithms are tested using hundreds of images and the shadow-highlight invariant algorithm is eventually chosen as the best performer. This is because it is immune to shadows and highlights. It is also robust as it was tested in different lighting conditions, weather conditions, and times of the day. Approximately 97% successful segmentation rate was achieved using this algorithm. Recognition of traffic signs is carried out using a fuzzy shape recogniser. Based on four shape measures - the rectangularity, triangularity, ellipticity, and octagonality, fuzzy rules were developed to determine the shape of the sign. Among these shape measures octangonality has been introduced in this research. The final decision of the recogniser is based on the combination of both the colour and shape of the sign. The recogniser was tested in a variety of testing conditions giving an overall performance of approximately 88%. -
Spectral Light Measuring
Spectral Light Measuring 1 Precision GOSSEN Foto- und Lichtmesstechnik – Your Guarantee for Precision and Quality GOSSEN Foto- und Lichtmesstechnik is specialized in the measurement of light, and has decades of experience in its chosen field. Continuous innovation is the answer to rapidly changing technologies, regulations and markets. Outstanding product quality is assured by means of a certified quality management system in accordance with ISO 9001. LED – Light of the Future The GOSSEN Light Lab LED technology has experience rapid growth in recent years thanks to the offers calibration services, for our own products, as well as for products from development of LEDs with very high light efficiency. This is being pushed by other manufacturers, and issues factory calibration certificates. The optical the ban on conventional light bulbs with low energy efficiency, as well as an table used for this purpose is subject to strict test equipment monitoring, and ever increasing energy-saving mentality and environmental awareness. LEDs is traced back to the PTB in Braunschweig, Germany (German Federal Institute have long since gone beyond their previous status as effects lighting and are of Physics and Metrology). Aside from the PTB, our lab is the first in Germany being used for display illumination, LED displays and lamps. Modern means to be accredited for illuminance by DAkkS (German accreditation authority), of transportation, signal systems and street lights, as well as indoor and and is thus authorized to issue internationally recognized DAkkS calibration outdoor lighting, are no longer conceivable without them. The brightness and certificates. This assures that acquired measured values comply with official color of LEDs vary due to manufacturing processes, for which reason they regulations and, as a rule, stand up to legal argumentation. -
Photometric Calibrations —————————————————————————
NIST Special Publication 250-37 NIST MEASUREMENT SERVICES: PHOTOMETRIC CALIBRATIONS ————————————————————————— Yoshihiro Ohno Optical Technology Division Physics Laboratory National Institute of Standards and Technology Gaithersburg, MD 20899 Supersedes SP250-15 Reprint with changes July 1997 ————————————————————————— U.S. DEPARTMENT OF COMMERCE William M. Daley, Secretary Technology Administration Gary R. Bachula, Acting Under Secretary for Technology National Institute of Standards and Technology Robert E. Hebner, Acting Director PREFACE The calibration and related measurement services of the National Institute of Standards and Technology are intended to assist the makers and users of precision measuring instruments in achieving the highest possible levels of accuracy, quality, and productivity. NIST offers over 300 different calibrations, special tests, and measurement assurance services. These services allow customers to directly link their measurement systems to measurement systems and standards maintained by NIST. These services are offered to the public and private organizations alike. They are described in NIST Special Publication (SP) 250, NIST Calibration Services Users Guide. The Users Guide is supplemented by a number of Special Publications (designated as the “SP250 Series”) that provide detailed descriptions of the important features of specific NIST calibration services. These documents provide a description of the: (1) specifications for the services; (2) design philosophy and theory; (3) NIST measurement system; (4) NIST operational procedures; (5) assessment of the measurement uncertainty including random and systematic errors and an error budget; and (6) internal quality control procedures used by NIST. These documents will present more detail than can be given in NIST calibration reports, or than is generally allowed in articles in scientific journals. In the past, NIST has published such information in a variety of ways.