Compressor Cooling

Total Page:16

File Type:pdf, Size:1020Kb

Compressor Cooling Compressor cooling Compressed air – the fourth utility A gas compressor is a mechanical compressed air are pneumatic tools, The major cooling applications for device that converts power into kinetic energy storage, production lines, compressors where heat exchangers energy by increasing the pressure of automated assembly stations, are used are: gas and reducing its volume. refrigeration, gas dusters and air-start • Air cooling systems. • Oil cooling Compressed air has become one of • Water cooling the most important power media used Another important power media is • Heat recovery in industry providing power for a compressed natural gas (CNG), which multitude of manufacturing operations. is made by compressing natural gas to In industry, compressed air is so widely less than 1% of the volume it occupies used that it is often regarded as the at standard atmospheric pressure. fourth utility, after electricity, natural gas CNG is generally used in traditional and water. General uses of combustion engines. Oil-free Compressor Oil Air Water Air cooling The compressed gas from the Oil cooling A multi-stage compressor can contain compressor is hot after compression, Both lubricated and oil-free one or several intercoolers. Since often 70-200°C. An aftercooler is used compressors need oil cooling. In compression generates heat, the to lower the temperature, which also oil-free compressors it is the lubrication compressed gas needs to be cooled results in condensation. The aftercooler oil for the gearbox that has to be between stages, making the is placed directly after the compressor cooled. In oil-injected compressors it is compression less adiabatic and more in order to precipitate the main part of the oil which is mixed with the isothermal. The inter-stage coolers the condensate as quickly as possible compressed air for lubrication, sealing typically result in some partial that would otherwise follow out into the and cooling that has to be cooled. condensation that is removed in vapor- system. The aftercooler is generally liquid separators. fitted with a vapor-liquid separator with automatic drainage. Oil-injected Compressor Oil Air Water Water cooling concentrated in the decreasing volume For compressor cooling A water cooler is generally used, direct and the excess is led off before the Alfa Laval offers: or indirect, to cool the closed loop gas leaves the compressor. The cooling water to the air/gas and oil energy used to produce compressed Air cooling coolers. Since this is typically an air or gas typically represents 80% • AlfaNova fusion-bonded plate heat outdoor installed air heat exchanger, of the total cost. Over 90% of the exchangers the water is mixed with anti-freeze energy supplied to the compressor • Copper brazed plate heat such as glycol. This is a common can be recovered. exchangers cooling method for CNG compressors. • Gasketed plate heat exchangers Air heat exchangers are particularly For water cooled compressors, the suitable when the availability of water is cooling water from the compressor can Oil cooling limited or as an alternative to cooling supplement a hot water flow. If the • Copper brazed plate heat towers. As air heat exchangers have a water is used for e.g., washing, exchangers closed cooling water loop – make-up cleaning or showers, a normal hot • Gasketed plate heat exchangers water, water contamination and water boiler is still required. However, chemicals to prevent algae can be the recovered heat is a supplement Water cooling avoided. that can reduce the load on the boiler. • AlfaBlue air heat exchangers This saves fuel and can possibly result Heat recovery in the use of a smaller boiler. Heat recovery When a gas is compressed heat is • Copper brazed plate heat emitted. The thermal energy is exchangers • Gasketed plate heat exchangers.
Recommended publications
  • Boiler & Furnace Combustion Imaging
    IMPAC Non-Contact Infrared Temperature Sensors IMPACApplication Non-Contact Note Infrared Temperature Sensors BOILER & FURNACE COMBUSTION IMAGING The Opportunity The continued rise of worldwide electricity consumption has put an ever increasing demand on power generation facilities. With coal fired power plants, this demand results in challenges to increase production while minimizing environmental impact. Optimizing the performance of the downtime. In addition, lance systems coal boiler can provide immediate typically operate blindly; attempting benefits and maximize the Rankine to uniformly target all boiler tubes for cycle efficiency. One common problem cleaning. It is possible to reduce the is the buildup of fly ash and soot furnace power to obtain a visual inspec- on the boiler tube surfaces which tion of some tubes, but the efficiency reduces the heat exchange efficiency. loss during this process is significant. These deposits (Slag) can be removed Properly tuning the combustion process with lances, and similar systems, but can help reduce the buildup of tube identifying when to implement this deposits, and can minimize emissions. action can be difficult to estimate and However, switching coal composition routine periodic lance operation can can further complicate the tuning cause thermal stress to boiler tubes, process, and lead to varying fouling of leading to failure and unscheduled the boiler tubes. Our Solution Advanced Energy leverages more than 25 years of infrared thermal imaging experience to developing the BoilerSpection™ SD solutions specifically designed to address the monitoring of heat exchange tubes in coal fired boilers and furnaces. Using a custom narrowband 3.9μm filter and precision boroscope optics, we view through boiler flames and provide the clearest image of boiler tubes available.
    [Show full text]
  • Consider Installing a Condensing Economizer, Energy Tips
    ADVANCED MANUFACTURING OFFICE Energy Tips: STEAM Steam Tip Sheet #26A Consider Installing a Condensing Economizer Suggested Actions The key to a successful waste heat recovery project is optimizing the use of the recovered energy. By installing a condensing economizer, companies can im- ■■ Determine your boiler capacity, prove overall heat recovery and steam system efficiency by up to 10%. Many average steam production, boiler applications can benefit from this additional heat recovery, such as district combustion efficiency, stack gas heating systems, wallboard production facilities, greenhouses, food processing temperature, annual hours of plants, pulp and paper mills, textile plants, and hospitals. Condensing economiz- operation, and annual fuel ers require site-specific engineering and design, and a thorough understanding of consumption. the effect they will have on the existing steam system and water chemistry. ■■ Identify in-plant uses for heated Use this tip sheet and its companion, Considerations When Selecting a water, such as boiler makeup Condensing Economizer, to learn about these efficiency improvements. water heating, preheating, or A conventional feedwater economizer reduces steam boiler fuel requirements domestic hot water or process by transferring heat from the flue gas to the boiler feedwater. For natural gas-fired water heating requirements. boilers, the lowest temperature to which flue gas can be cooled is about 250°F ■■ Determine the thermal to prevent condensation and possible stack or stack liner corrosion. requirements that can be met The condensing economizer improves waste heat recovery by cooling the flue through installation of a gas below its dew point, which is about 135°F for products of combustion of condensing economizer.
    [Show full text]
  • Modu-Fire® Forced Draft Gas-Fired Boiler 2500 - 3000
    MODU-FIRE® FD 2500-3000 Rev. 1.1 (11/21/11) MODU-FIRE® FORCED DRAFT GAS-FIRED BOILER 2500 - 3000 C.S.A. Design-Certified Complies with ANSI Z21.13/CSA 4.9 Gas-Fired Low Pressure Steam and Hot Water Boilers ASME Code, Section IV Certified by Harsco Industrial, Patterson-Kelley C.S.A. Design-Certified Complies with ANSI Z21.13/CSA 4.9 Gas-Fired Low Pressure Steam and Hot Water Boilers Model #:_______ Serial #______________________ Start-Up Date: _______________________ Harsco Industrial, Patterson-Kelley 100 Burson Street East Stroudsburg, PA 18301 Telephone: (877) 728-5351 Facsimile: (570) 476-7247 www.harscopk.com ©2010 Harsco Industrial, Patterson Kelley Printed : 6/27/2012 MODU-FIRE® Forced Draft Boiler 1 INTRODUCTION ...................................................................................................... 4 2 SAFETY .................................................................................................................... 4 2.1 General ............................................................................................................................ 4 2.2 Training ............................................................................................................................ 4 2.3 Safety Features ................................................................................................................ 5 2.4 Safety Labels ................................................................................................................... 5 2.5 Safety Precautions ..........................................................................................................
    [Show full text]
  • Comparing Exchangers for Boiler Water/High Temperature Indirect Water Heaters HUBBELL Case Study 1
    HUBBELLHEATERS.COM Comparing Exchangers for Boiler Water/High Temperature Indirect Water Heaters HUBBELL Case Study 1 There are a few different options available if you are looking for a hydronic water heater that uses boiler water or high temperature hot water to heat potable water. One of the biggest decisions regarding boiler water heater types is determining which heat exchanger the system should utilize. Some models use a tube bundle heat exchanger while others use a plate and frame or brazed plate system. Tube bundle heat exchangers and plate and frame/brazed plate systems vary greatly in the way that they heat water and maintain a certain temperature. Both produce hot water, but in different ways. Hubbell offers a wide range of hydronic water heating systems for water to water applications, which can be customized to meet your needs. Let’s take a look at the heat exchangers for hydronic water heaters that should be considered by end users. Tube Bundle Tube bundles are designed to transfer heat from a, boiler water, solar water or high temperature hot water (HTHW) system to the domestic potable hot water system. The primary heat source, in this case boiler water or HTHW, travels through the tubing in the bundle within the shell, and transfers heat to the secondary system (potable water) without allowing either liquid to come into direct contact with the other. Tube bundle heat exchangers are ideal for older non-condensing water heating systems, specifically ones that use oil to produce heat. Older boilers are more suitable for the tube bundle type heat exchanger as they deal with higher non-condensing water temperatures.
    [Show full text]
  • Boiler & Cooling Tower Control Basics
    Boiler & Cooling Tower Control Basics By James McDonald, PE, CWT Originally Published: CSTR – May 2006 For those of us who have been around boilers and cooling towers for years now, it can be easy to forget how we may have struggled when we first learned about controlling the chemistry of boilers and cooling towers. After running all the chemical tests, where do you start when the phosphate is too high, conductivity too low, sulfite nonexistent, and molybdate off the charts? Even better, how would you explain this decision process to a new operator? Cycles of Concentration The first place you always start is cycles of concentration (cycles). You may measure cycles by measuring conductivity or chlorides. If everything else is running normally, when the cycles are too high, everything else should be proportionally too high. When the cycles are too low, everything else should be proportionally too low. When the cycles are brought back under control, the other parameters should come back within range too. Example We wish to run a boiler at 2,000 µmhos, 45 ppm phosphate, and 40 ppm sulfite; however, the latest tests show 1,300 µmhos, 29 ppm phosphate, and 26 ppm sulfite. The conductivity is 35% lower than what it should be. Doing the math ((45- 29)/45=35%), we see that the phosphate and sulfite are also 35% too low. By reducing boiler blowdown and bringing the conductivity back within control, the phosphate and sulfite should be within their control range too. Boilers 100 Beyond Cycles Whether we’re talking about boilers or cooling towers, we know if we reduce blowdown, cycles will increase, and if we increase blowdown, cycles will decrease.
    [Show full text]
  • Heat Transfer Model of a Rotary Compressor S
    Purdue University Purdue e-Pubs International Compressor Engineering Conference School of Mechanical Engineering 1992 Heat Transfer Model of a Rotary Compressor S. K. Padhy General Electric Company Follow this and additional works at: https://docs.lib.purdue.edu/icec Padhy, S. K., "Heat Transfer Model of a Rotary Compressor" (1992). International Compressor Engineering Conference. Paper 935. https://docs.lib.purdue.edu/icec/935 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html HEAT TRANSFER MODEL OF A ROTARY COMPRESSOR Sisir K. Padhy General Electric C_ompany Appliance Park 5-2North, Louisville, KY 40225 ABSTRACT Energy improvements for a rotary compressor can be achieved in several ways such as: reduction of various electrical and mechanical losses, reduction of gas leakage, better lubrication, better surface cooling, reduction of suction gas heating and by improving other parameters. To have a ' better understanding analytical/numerical analysis is needed. Although various mechanical models are presented to understand the mechanical losses, dynamics, thermodynamics etc.; little work has been done to understand the compressor from a heat uansfer stand point In this paper a lumped heat transfer model for the rotary compressor is described. Various heat sources and heat sinks are analyzed and the temperature profile of the compressor is generated. A good agreement is found between theoretical and experimental results. NOMENCLATURE D, inner diameter D.
    [Show full text]
  • An Overview of the State of Microgeneration Technologies in the UK
    An overview of the state of microgeneration technologies in the UK Nick Kelly Energy Systems Research Unit Mechanical Engineering University of Strathclyde Glasgow Drivers for Deployment • the UK is a signatory to the Kyoto protocol committing the country to 12.5% cuts in GHG emissions • EU 20-20-20 – reduction in EU greenhouse gas emissions of at least 20% below 1990 levels; 20% of all energy consumption to come from renewable resources; 20% reduction in primary energy use compared with projected levels, to be achieved by improving energy efficiency. • UK Climate Change Act 2008 – self-imposed target “to ensure that the net UK carbon account for the year 2050 is at least 80% lower than the 1990 baseline.” – 5-year ‘carbon budgets’ and caps, carbon trading scheme, renewable transport fuel obligation • Energy Act 2008 – enabling legislation for CCS investment, smart metering, offshore transmission, renewables obligation extended to 2037, renewable heat incentive, feed-in-tariff • Energy Act 2010 – further CCS legislation • plus more legislation in the pipeline .. Where we are in 2010 • in the UK there is very significant growth in large-scale renewable generation – 8GW of capacity in 2009 (up 18% from 2008) – Scotland 31% of electricity from renewable sources 2010 • Microgeneration lags far behind – 120,000 solar thermal installations [600 GWh production] – 25,000 PV installations [26.5 Mwe capacity] – 28 MWe capacity of CHP (<100kWe) – 14,000 SWECS installations 28.7 MWe capacity of small wind systems – 8000 GSHP systems Enabling Microgeneration
    [Show full text]
  • Why Does the Wisconsin Boiler and Pressure Vessel Code, 636 41
    Why does the Wisconsin Boiler and Pressure Vessel Code, SPS 341, regulate air compressors? By Industry Services Division Boiler and Pressure Vessels Program Almost everyone forms a definite picture in their mind when they hear the term “air compressor.” They probably think of a steel tank of some shape and dimension, with an electric motor, and an air pump mounted on top of the tank. To better understand the requirements of the Wisconsin Boiler Code, SPS 341, pertaining to air compressors, we need to have some common terminology. If a person wanted to purchase an “air compressor” at a hardware or home supply store, they would certainly be offered the equipment described above, consisting of three separate mechanical devices; the motor, the pump, and the storage tank. First, there is an electric motor, used to provide power to the device that pumps air to high pressure. This pumping device is the only part of the unit that is properly called an "air compressor." The compressor delivers high-pressure air to the third and final part of the mechanical assembly, the air storage tank; commonly called a pressure vessel. Because the pressure vessel receives pressurized air, this is the only part of the device described above that is regulated SPS 341. SPS 341 regulates pressure vessels when the pressure vessel's volume capacity is 90 gallons (12 cubic feet) or larger, and the air pressure is 15 pounds per square inch or higher. A typical pressure vessel of this size would be 24 inches in diameter and 48 inches long. In industrial settings, it is common practice to mount very large air compressors in a separate location from the pressure vessels.
    [Show full text]
  • Performance Comparison Between an Absorption-Compression Hybrid Refrigeration System and a Double-Effect Absorption Refrigeration Sys-Tem
    Available online at www.sciencedirect.com ScienceDirect Available online at www.sciencedirect.com Procedia Engineering 00 (2017) 000–000 ScienceDirect www.elsevier.com/locate/procedia Procedia Engineering 205 (2017) 241–247 10th International Symposium on Heating, Ventilation and Air Conditioning, ISHVAC2017, 19- 22 October 2017, Jinan, China Performance Comparison between an Absorption-compression Hybrid Refrigeration System and a Double-effect Absorption Refrigeration Sys-tem Jian Wang, Xianting Li, Baolong Wang, Wei Wu, Pengyuan Song, Wenxing Shi* Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Department of Building Science, Tsinghua University, Haidian District, Beijing 100084, China Abstract Conventional absorption refrigeration systems (ARSs), which are mainly driven by heat, have a competitive primary energy efficiency (PEE) compared with chillers driven by electricity. In the typical ARS, a large quantity of high-temperature heat is supplied into the generator, while a substantial amount of low-temperature heat is rejected to the environment from the condenser, it’s a huge waste. In order to decrease the input heat for generator and enhance the performance of conventional ARS, a kind of absorption-compression hybrid refrigeration system recovering condensation heat for generation (RCHG-ARS) was ever proposed. In the present study, the models of both RCHG-ARS and double-effect absorption refrigeration system (DEARS) are established, and the effects of different parameters on them are simulated and compared with each other. As a conclusion, the PEE of RCHG-ARS can be 29.0% higher than that of DEARS, and RCHG-ARS has a wider working conditions than DEARS due to the existence of the compressor.
    [Show full text]
  • Bendix® Ba-922® Sae Universal Flange Air Compressor
    compressors BENDIX® BA-922® SAE UNIVERSAL FLANGE AIR COMPRESSOR High output compressed air generation for ultra demanding commercial & industrial applications. Experience Counts Ideal for niche industrial, agricultural, and For generations, Bendix Commercial Vehicle Systems (Bendix CVS) has petroleum applications, the universal flange been leading the way in air charging system experience and expertise. model . More fleets specify our hard-working products and systems than any other. Features an adapter mount to meet SAE J744 Bendix CVS continues its legacy of quality, reliability and durability with hydraulic pump, engine & motor mounting, a next generation high-performing, energy-saving compressor option – and drive dimensions standards; the Bendix® BA-922® SAE Universal Flange compressor. Can be mounted at several different angles An Ideal Solution For A Wide Range Of depending on physical constraints and application necessities; and Unique Applications Utilizing a standard SAE B Flange, and a 15-tooth BB spline for strength, Is driven by an engine PTO, hydraulic motor, the Bendix® BA-922® SAE compressor is designed to address a wide or electric motor. Option for belt drive as well. variety of commercial and industrial applications. Its clock-able front adapter allows the compressor to be easily mounted in several different positions depending on your requirement. Building On The Power Of The Bendix® BA-922® Compressor: High Air Delivery A dependable workhorse, the Bendix® BA-922® compressor provides maximum air delivery even at low speeds. Its high-output, two-cylinder design supplies 32 cfm (cubic feet per minute) displacement at 1,250 rpm (revolutions per minute). Power like this delivers the ability to recharge the system quickly and efficiently – even at low speeds – making it ideal for more demanding brake system applications.
    [Show full text]
  • Use Feedwater Economizers for Waste Heat Recovery, Energy Tips
    ADVANCED MANUFACTURING PROGRAM Energy Tips: STEAM Steam Tip Sheet #3 Use Feedwater Economizers for Waste Heat Recovery Suggested Actions ■■ Determine the stack temperature A feedwater economizer reduces steam boiler fuel requirements by transferring after the boiler has been tuned heat from the flue gas to incoming feedwater. Boiler flue gases are often to manufacturer’s specifications. rejected to the stack at temperatures more than 100°F to 150°F higher than The boiler should be operating the temperature of the generated steam. Generally, boiler efficiency can at close-to-optimum excess be increased by 1% for every 40°F reduction in flue gas temperature. By air levels with all heat transfer recovering waste heat, an economizer can often reduce fuel requirements by 5% surfaces clean. to 10% and pay for itself in less than 2 years. The table provides examples of ■■ Determine the minimum the potential for heat recovery. temperature to which stack gases Recoverable Heat from Boiler Flue Gases can be cooled subject to criteria such as dew point, cold-end Recoverable Heat, MMBtu/hr corrosion, and economic heat Initial Stack Gas transfer surface. (See Exhaust Temperature, °F Boiler Thermal Output, MMBtu/hr Gas Temperature Limits.) 25 50 100 200 ■■ Study the cost-effectiveness of installing a feedwater economizer 400 1.3 2.6 5.3 10.6 or air preheater in your boiler. 500 2.3 4.6 9.2 18.4 600 3.3 6.5 13.0 26.1 Based on natural gas fuel, 15% excess air, and a final stack temperature of 250˚F. Example An 80% efficient boiler generates 45,000 pounds per hour (lb/hr) of 150-pounds-per-square-inch-gauge (psig) steam by burning natural gas.
    [Show full text]
  • Compact Heat Exchangers for Mobile Co2 Systems
    COMPACT HEAT EXCHANGERS FOR MOBILE CO2 SYSTEMS A. Hafner SINTEF Energy Research Refrigeration and Air Conditioning Trondheim (Norway) ABSTRACT The natural refrigerant carbon dioxide (CO2) with all its advantages offers new possibilities of efficient heating and cooling at different climates. In reversible air conditioning systems the capacity and efficiency in cooling mode is seen to be most important. The efficiency of the reversible interior heat exchanger depends on the design of the heat exchanger. Efficiency reduction is among other factors caused by refrigerant- side pressure drop, heat conduction, refrigerant- and air maldistribution. Uniform air temperatures at the outlet of the heat exchanger are an important aspect regarding comfort and control of the mobile HVAC system. A prototype CO2 system with a separator, refrigerant pump and a single pass heat exchanger was tested under varies conditions. The tests were performed at low compressor revolution speed i.e. idle conditions. Compared with a baseline heat exchanger of equal size, the use of an external operated pump to circulate the refrigerant through the heat exchanger, increased the cooling capacity at equal pressure levels by up to 14 %. At equal cooling capacities the COP increased by up to 23 %. Airside temperature distribution was more uniform with this way of operating the system. 1 INTRODUCTION Several authors for example Hrnjak et al 2002, Nekså et al. 2001 describe CO2 systems where flash gas was bypassed the evaporator and thereafter reunified with the leaving gas of the evaporator. With such a system concept only liquid refrigerant enters the evaporator which has an positive effect on distribution of the refrigerant into 20000 the microchannels.
    [Show full text]