M.4.1 M.4.1 Only
Total Page:16
File Type:pdf, Size:1020Kb
INSTALL PER UL SYSTEM W-L-1054 USE HILTI FS-ONE MAX FIRESTOP SEALANT INSTALL PER UL SYSTEM W-L-1389 USE HILTI FS-ONE MAX FIRESTOP SEALANT METAL PIPE TYPE MAX. DIA. METAL PIPE STEEL PIPE (SCH. 10 TYPE MAX. DIA. Notes: 30" OR HEAVIER) STEEL PIPE (SCH. 5 OR HEAVIER) 2" 1. Refer to the following specifications for firestopping. CAST IRON PIPE 30" STEEL CONDUIT 2" a. 07 84 00 Firestopping COPPER PIPE 6" b. 07 84 13 Penetration Firestopping STEEL CONDUIT 6" EMT 2" c. 22 00 00 Plumbing EMT 4" d. 23 00 00 HVAC e. 26 00 00 Electrical f. 27 06 37 Communication For Quality Control requirements, refer to the Quality Control 1 METAL PIPE THROUGH GYPSUM WALL ASSEMBLY (1-HR.) 2 MULTIPLE METAL PIPES THROUGH GYPSUM WALL ASSEMBLY (1-HR.) portion of the specification. NOT TO SCALE NOT TO SCALE 2. Details shown are typical details, containing general information M.4.1 M.4.1 only. Always refer to the full UL system detail for complete system requirements. If field conditions do not match requirements of details, approved alternate details shall be utilized. Design requirements, field conditions and dimensions ATTACH COLLAR WITH HILTI TOGGLER BOLTS need to be verified for compliance with the details, including but not limited to the following: INSTALL PER UL SYSTEM W-L-2078 SLEEVE OPTIONAL USE HILTI FS-ONE MAX FIRESTOP * Fire Rating (F-Rating) INSTALL PER UL SYSTEM W-L-5028 SEALANT AND CP 643N OR CP 644 USE HILTI FS-ONE MAX FIRESTOP SEALANT * Temperature Rating (T-Rating) FIRESTOP COLLAR INSTALL PER UL SYSTEM W-L-2128 USE HILTI FS-ONE MAX FIRESTOP SEALANT * Leakage Rating (L-Rating) PLASTIC PIPE * Water Rating (W-Rating) TYPE MAX. DIA. * Annular Space PVC PIPE (SCH. 40) PLASTIC PIPE METAL PIPE * Percent Fill (CELLULAR OR SOLID 10" TYPE MAX. DIA. TYPE MAX. DIA. CORE) * Movement PVC PIPE (SCH. 40) STEEL PIPE (SCH. 40 4" CPVC PIPE (SDR 13.5) (CELLULAR OR SOLID 2" OR HEAVIER) * Type and thickness of fire-rated construction. (CLOSED PIPING CORE) 10" COPPER PIPE OR SYSTEM ONLY) 2" 3. If alternate details matching the field conditions are not available, CPVC PIPE (SDR 13.5) TUBING ABS PIPE (SCH. 40) (CLOSED PIPING 2" manufacturer's engineering judgment drawings are acceptable. (CELLULAR OR SOLID 6" SYSTEM ONLY) Contact Hilti Inc. for alternative systems or Engineering CORE) AB/PVC INSULATION Judgment (800-879-8000) Drawings shall follow the International FRPP PIPE (SCH. 40) 6" Firestop Council (IFC) Guidelines for Evaluating Firestop PVDF PIPE (SDR 32.5) 4" Systems Engineering Judgments. PLASTIC PIPE WITH AB/PVC INSULATION THROUGH GYPSUM 4. References: 3 PLASTIC PIPE THROUGH GYPSUM WALL ASSEMBLY (1-HR.) 4 PLASTIC PIPE THROUGH GYPSUM WALL ASSEMBLY (1-HR.) 5 WALL ASSEMBLY (1-HR.) * 2013 Underwriter's Laboratories Fire Resistance Directory, NOT TO SCALE NOT TO SCALE NOT TO SCALE Volumes 1 & 2 M.4.1 M.4.1 M.4.1 * NFPA 101 Life Safety Code Laboratories Fire Resistance Directory (volume 2.)" * NFPA 70 - National Electric Code UL or Intertek Classification or the intended temperature or fire ratings. 3. For additional information on the details, refer to the most current "Underwriter's 2. Details shown are up to date as of February 2015. * All governing local and regional building codes 1. Any modification to these details could result in an application/system not meeting the 5. Firestop System installation must meet requirements of ASTM STEEL RETAINING ANGLES E-814 (UL 1479) tested assemblies that provide a fire rating INSTALL PER UL SYSTEM W-L-7042 <Notes to designer (delete this note after reading and replace with title block information)> INSTALL PER UL SYSTEM W-L-5029 USE HILTI FS-ONE MAX, CP 601S, OR CP equal to that of construction being penetrated. USE HILTI FS-ONE MAX FIRESTOP SEALANT 606 FIRESTOP SEALANT 6. All rated through-penetration assemblies shall be prominently labeled with a Hilti Firestop Label equipped with a QR code with METAL PIPE the following information: TYPE MAX. DIA. INSTALL PER UL SYSTEM W-L-7155 METAL DUCT *Warning! - Do Not Disturb STEEL PIPE (SCH. 10 USE HILTI FS-ONE MAX, CP 606, OR CFS-S SIL GG 12" OR HEAVIER) TYPE MAX. DIA. FIRESTOP SEALANT *Through Penetration Firestop System CAST OR DUCTILE SPIRAL WOUND SHEET * UL System # * Product(s) used 12" IRON PIPE METAL DUCT (MIN. 24 20" * Hourly Rating (F-Rating) GA.) COPPER PIPE OR 6" TUBING SHEET METAL DUCT * Installation Date 12" METAL DUCT (MIN. 28 GA.) MAX. 100" X 100" *Contractor's Name 7. For outlet boxes requiring protection, use only Wall Opening GLASS FIBER OR CALCIUM SILICATE INSULATION Protective Materials, category CLIV as classified by Underwriter's Laboratories, Fire Resistance Directory (Volume 1.) JOB NUMBER: METAL PIPE WITH GLASS FIBER OR CALCIUM SILICATE METAL DUCT (WITHOUT DAMPER) THROUGH GYPSUM WALL 6 INSULATION THROUGH GYPSUM WALL ASSEMBLY (1-HR.) 7 ASSEMBLY (1-HR.) 8 METAL DUCT THROUGH GYPSUM WALL ASSEMBLY (1-HR.) DRAWN: M.4.1 NOT TO SCALE M.4.1 NOT TO SCALE M.4.1 NOT TO SCALE CHECKED: ISSUE DATE: STEEL RETAINING ANGLES REVISIONS: INSTALL PER UL SYSTEM W-L-8079 USE HILTI FS-ONE MAX FIRESTOP SEALANT CONTENTS: INSTALL PER UL SYSTEM W-L-7156 USE HILTI FS-ONE MAX FIRESTOP SEALANT MECHANICAL PENETRATIONS GYPSUM WALL 1 HR. METAL DUCT 100" X 100" SHEET NAME: GLASS FIBER INSULATION M.4.1 SHEET NUMBER: METAL DUCT WITH GLASS FIBER INSULATION THROUGH 9 GYPSUM WALL ASSEMBLY (1-HR.) 10 MULTIPLE PENETRATIONS THROUGH GYPSUM WALL ASSEMBLY (1-HR.) M.4.1 NOT TO SCALE M.4.1 NOT TO SCALE.