CLOUD, POUR. AND BOILING POINT CLOUD AND POUR POINT 500/S CLOUD AND POUR POINT REFRIGERATOR 4 4 PLACES ASTM D97 IP 15 POUR POINT OF PRODUCTS Light and resistant structure made in die-casted aluminium covered This test method is intended for use on any petroleum product. Suitable by special plastic material, fitted with four wheels allowing movement. for black specimens, cylinder stock, and nondistillate fuel oil and for PVC cover with 16 wells in aluminium block (4 for each ) testing the fluidity of a residual fuel oil at a specified temperature is for accomodate 16 graduated jars, equipped with 4 holes where the described thermometers are placed. 16 small stand-by covers are enclosed. Working temperatures: 0, -18, -33, -51°C. Temperature is controlled by ASTM D2500 IP 219 CLOUD POINT OF PETROLEUM PRODUCTS 4 digital thermoregulator (one for each temperature) fitted with a probe This test method covers only petroleum products that are transparent PT100 A. Automatic defrosting device, earth leakage circuit breaker. in layers 40mm in thickness, and with a cloud point below 49°C CFC free refrigerant are used.

ASTM D5853 POUR POINT OF CRUDE OILS (535/S) 510/S CLOUD AND POUR POINT REFRIGERATOR 4 TEMPERATURES 1 PLACE IP 309; ISO 3015 ; ISO 3016; DIN 51428; DIN 51597 Light and resistant structure made in die-casted aluminium covered by special plastic material, fitted with four wheels allowing movement. PVC cover with 4 metal block wells (one for each temperature) for accomodate 490 4 graduated jars, equipped with 4 holes where the thermometers are placed. 4 small stand-by covers are enclosed. Working temperatures: 0, -18, -33, -51°C. Temperature is controlled by 4 digital thermoregulator (one for each temperature) fitted with a probe PT100 A. Automatic defrosting device, earth leakage circuit breaker. CFC free refrigerant gases are used.

520/S CLOUD AND POUR POINT REFRIGERATOR 3 TEMPERATURES 4 PLACES Light and resistant structure made in die-casted aluminium covered by special plastic material, fitted with four wheels allowing movement. PVC cover with 12 wells in aluminium block (4 for each temperature) for accomodate 12 graduated jars, equipped with 3 holes where the thermometers are placed. 12 small stand-by covers are enclosed. Working temperatures: 0, -18, -33°C. Temperature is controlled by 3 digital thermoregulator (one for each temperature) fitted with a probe PT100 A. Automatic defrosting device, earth leakage circuit breaker. CFC free refrigerant gases are used.

530/S CLOUD AND POUR POINT REFRIGERATOR 3 TEMPERATURES 1 PLACE Light and resistant structure made in die-casted aluminium covered by special plastic material, fitted with four wheels allowing movement. PVC cover with 3 metal block wells in aluminium block (one for each 490/S/140 CLOUD AND POUR POINT REFRIGERATOR UP TO -69°C temperature) for accomodate 3 graduated jars, equipped with 3 holes Light and resistant structure made in die-casted aluminium covered by where the thermometers are placed. 3 small stand-by covers are special plastic material, fitted with four wheels allowing movement. PVC enclosed. Working temperatures: 0, -18, -33°C. Temperature is controlled cover with four wells in aluminium block for accomodate four graduated by 3 digital thermoregulator (one for each temperature) fitted with a probe jars, equipped with a hole where the thermometer is placed. Four small PT100 A. Automatic defrosting device, earth leakage circuit breaker. CFC stand-by covers are enclosed. Temperature is controlled by digital ther- free refrigerant gases are used. moregulator fitted with a probe PT100 A. Automatic defrosting device, heating element controlled by a indipendent switch for a quick return to a 531/S CLOUD AND POUR POINT REFRIGERATOR ambient temperature, earth leakage circuit breaker. CFC free refrigerant 5 TEMPERATURES 4 PLACES gases are used Resistant structure painted with anti-acid epoxidic products, fitted with four wheels allowing movement. PVC cover with 20 wells in aluminium block (4 for each temperature) for accomodate 20 graduated jars, equipped with 5 holes where the thermometers are placed. 20 small 532/S stand-by covers are enclosed. Working temperatures: 0, -18, -33, -51, -69°C. Temperature is controlled by 5 digital thermoregulator (one for each temperature) fitted with a probe PT100 A. Automatic defrosting device, earth leakage circuit breaker. CFC free refrigerant gases are used.

532/S CLOUD AND POUR POINT REFRIGERATOR 5 TEMPERATURES 1 PLACE Resistant structure painted with anti-acid epoxidic products, fitted with four wheels allowing movement. PVC cover with 5 metal block wells (one for each temperature) for accomodate 5 graduated jars, equipped with 5 holes where the thermometers are placed. 5 small stand-by covers are enclosed. Working temperatures: 0, -18, -33, -51, -69°C. Temperature is controlled by 5 digital thermoregulator (one for each temperature) fitted with a probe PT100 A. Automatic defrosting device, earth leakage circuit breaker. CFC free refrigerant gases are used.

535 /S POUR POINT OF CRUDE OILS ASTM D5853 Resistant structure painted with anti-acid epoxidic products, fitted with four wheels allowing movement. PVC cover with 20 wells (4 for each temperature) for accomodate 20 graduated jars, equipped with 5 holes where is poured and thermometers are placed. 20 small stand- by covers are enclosed. Working temperatures: 0, -18, -33, -51, -69°C. Temperature is controlled by 5 digital thermoregulator (one for each temperature) fitted with a probe PT100 A. Automatic defrosting device, 12 CLOUD, POUR. FREEZING AND BOILING POINT9 earth leakage circuit breaker. CFC free refrigerant gases are used. Water FREEZING POINT bath up to 100°C, test vessel made in stainless steel tested to 10bar

ACCESSORIES ASTM D2386 IP 16 ISO 3013 DIN 51421 FREEZING POINT OF 10-0491 TEST JAR AVIATION FUELS (2370, 2375) Graduated glassware ASTM, pack of 4 Covers the determination of the temperature below which 10-0492 CORK COVER hydrocarbon crystals may form in aviation turbine fuels and aviation For centering thermometer, pack of 4 gasoline 10-0493 CORK DISK For test jar, pack of 4 10-0494 INSULATING GASKET Pack of 4 T-AS5C THERMOMETER ASTM 5C IP 1C T-AS6C THERMOMETER ASTM 6C IP 2C 2375/2 T-0500/POZ THERMOMETER 30 -70°C (for well) T-AS61C THERMOMETER ASTM 61C IP 63C (only for 535/S)

SPARE PARTS 10-0491 TEST JAR, pack of 4 10-0492 CORK COVER, pack of 4 10-0493 CORK DISK, pack of 4 10-0494 INSULATING GASKET, pack of 4 16-0024 DIGITAL THERMOREGULATOR 14-0006 PT100 PROBE. L=65 11-0017 DEFROSTING HEATER 10W 11-0018 DEFROSTING HEATER 15W

540

2370 FREEZING POINT ASTM D 2386 Consisting of double tube 20x230mm fitted with cap, brass wire stirrer and brass stopping box, Dewar jar 75x280mm mount-based.

2375 ELECTRIC FREEZING POINT ACC. ASTM D 2386 Consisting of double tube 20x230mm fitted with cap, geared motor 540 CLOUD AND POUR POINT APPARATUS for stirring with brass wire stirrer and brass stopping box, Dewar jar 75x280mm mount-based. Conventional CO2 model. Dewar jar with internal brass support and stainless steel base, optical glass test tube according to the method, thermometer cap, centering gasket, brass tube fitted with bottom disc. 2375/2 ELECTRIC FREEZING POINT ACC. ASTM D 2386 (2 PLACES) ACCESSORIES ACCESSORIES T-AS5C THERMOMETER ASTM 5C IP 1C T-AS114C THERMOMETER ASTM 114C IP 14C T-AS6C THERMOMETER ASTM 6C IP 2C SPARE PARTS SPARE PARTS 15-2371 DOUBLE TUBE 10-0491 TEST JAR, pack of 4 15-2372 WIRE STIRRER 10-0492 CORK COVER, pack of 4 18-2373 DEWAR JAR 75x280mm 10-0493 CORK DISK, pack of 4 15-2374 CAP 10-0494 INSULATING GASKET, pack of 4 18-0541 DEWAR

13 CLOUD, POUR. FREEZING AND BOILING POINT ASTM D1177 FREEZING POINT OF AQUEOUS ENGINE COOLANTS COLD FILTER PLUGGING POINT (CFPP) (2380, 2385) Covers the determination of the freezing point of an aqueous engine ASTM D6371 IP 309 DIN 51428 COLD FILTER PLUGGING POINT coolant in the laboratory OF DIESEL AND HEATING FUELS (2540) Determination of the cold filter plugging point (CFPP) temperature of diesel and domestic heating fuels by measuring the temperature at which the sample ceases to flow through a wire mesh filter 2380 2540 COLD FILTER PLUGGING POINT (CFPP) ASTM D6371 31x125mm test tube with a set of neoprene gasket, 3-hole Teflon stopper, 46mm dia. jacket, 20ml Pyrex pipette, wire filter equipped with filtering disc 325 M, U-shaped glass pressure gauge, 3-way stopcock, junction glass tubes, cap, bottle. ACCESSORIES 490/S/140 CLOUD AND POUR POINT REFRIGERATOR UP TO -69°C 2460/RC4D DOUBLE-STAGE ROTATING PUMP FOR VACUUM 10-0331 ANALOG STOPWATCH 10-0332 DIGITAL STOPWATCH T-AS5C THERMOMETER ASTM 5C IP 1C T-AS6C THERMOMETER ASTM 6C IP 2C

SPARE PARTS 15-2540 U-SHAPED GLASS PRESSURE GAUGE 15-2541 TEST TUBE 15-2542 JACKET 15-2543 PYREX PIPETTE 15-2544 FILTERING DISC 15-2544/F FILTER FOE FILTERING DISC 15-2545 TEFLON CAP 15-2546 3-WAY STOPCOCK 15-2547 BOTTLE 2380 ELECTRIC FREEZING POINT ASTM D1177 15-2548 3-HOLE TEFLON STOPPER Consisting of double tube Øint. 35x200mm fitted with cap, mounted 15-2549 JUNCTION GLASS TUBES Dewar jar Ø95x195mm, geared motor for stirring at 80rpm with wire stirrer, digital thermometer. This item is mounted on a plate structure ASTM D852 SOLIDIFICATION POINT OF BENZENE (2340) painted with anti-acid epoxidic products. Determination of the solidification point of benzene 2380/2 ELECTRIC FREEZING POINT ASTM D177 (2 PLACES)

SPARE PARTS 2340 15-2381 DOUBLE TUBE 15-2382 WIRE STIRRER 18-2383 DEWAR JAR 95x195mm

2385 ELECTRIC FREEZING POINT ASTM D1177 Consisting of double tube Øint. 35x200mm fitted with cap, geared motor for stirring at 80rpm with wire stirrer. This item is mounted on a tripod for place on refrigerator bench. ACCESSORIES 490/S/150 CLOUD AND POUR POINT REFRIGERATOR UP TO -69°C

SPARE PARTS 15-2381 DOUBLE TUBE 15-2382 WIRE STIRRER

BOILING POINT

ASTM D1120 BOILING POINT OF ENGINE COOLANTS (2320) Covers the determination of the equilibrium boiling point of engine 2340 SOLIDIFICATION POINT OF BENZENE ASTM D852 coolants Consisting of: 1 cooling bath cup (1 liter dewar with stainless steel stand), 1 cover for jacket tube with opening for dry ice, 1 jacket tube 2320 BOILING POINT ASTM D1120 25x150mm, 1 test tube 15x125mm, 1 stopper for test tube, 1 stopper 100ml flask, "15" tapered joint condenser, "12" taper for thermometer,. for thermometer, stirrer ring shaped stainless steel wire dia.2mm ACCESSORIES ACCESSORIES T-AS112C THERMOMETER ASTM 112C 1290/100 HEATING MANTLES T-AS2C THERMOMETER ASTM 2C SPARE PARTS 18-2341 DEWAR SPARE PARTS 15-2342 JACKET TUBE 25x150MM 15-2321 FLASK 15-2343 TEST TUBE 15x125MM, conf.10 pz. 15-2322 CONDENSER 15-2344 COVER FOR JACKET TUBE 15-2323 CONICAL CONNECTION 15-2345 STOPPER FOR TEST TUBE T-AS2C THERMOMETER ASTM 2C 15-2346 STOPPER FOR THERMOMETER 15-2347 STAINLESS STEEL WIRE