Bio Clean CPSTM

Total Page:16

File Type:pdf, Size:1020Kb

Bio Clean CPSTM Comprehensive Stormwater Solutions Guide 2021v3 CATALOG Storage | Biofiltration | Filtration Separation | Trash Capture | Specialty Filters Table of Contents Product Categories & Solutions Storage Products Page 4 - 5 UrbanPondTM ...........................................................................................................................................Page 4 Biofiltration Products Page 6 - 13 Modular Wetlands® Linear ................................................................................................................Page 6 WetlandMod® .....................................................................................................................................Page 10 Modular Wetlands® Fiberglass ...................................................................................................... Page 12 Filtration Products Page 14 - 19 Kraken® Filter .......................................................................................................................................Page 14 Water PolisherTM .................................................................................................................................. Page 18 For over 20 years, Bio Clean has proudly offered the industry's most dependable and effective stormwater solutions. We are constantly Separation Products Page 20 - 25 innovating, and our superior product line and engineering services TM SciCloneX Separator ......................................................................................................................Page 20 are all designed to meet your local challenges and stormwater SciClone® Separator ..........................................................................................................................Page 22 compliance goals. DSBB Separator (Debris Separating Baffle Box) ...................................................................... Page 24 Bio Clean’s Stormwater Solutions Guide is a comprehensive reference catalog for our full line of Storage & Detention Systems, Trash Capture Products Page 26 - 33 Biofilters, Membrane Filters, Hydrodynamic Separators, Screen & Catch Basin Inlet Filters ................................................................................................................... Page 26 Trash Capture Devices, and Specialty Products. Full Capture Type .........................................................................................................................Page 28 Kraken® Filter Type ..................................................................................................................... Page 28 Bio Clean ARSTM ..................................................................................................................................Page 30 Learn more or contact us at: BioCleanEnvironmental.com Bio Clean CPSTM ...................................................................................................................................Page 32 Curb Guard ...........................................................................................................................................Page 33 Specialty Products Page 34 - 35 Downspout Filter ............................................................................................................................... Page 34 COMPREHENSIVE STORMWATER SOLUTIONS GUIDE STORAGE PRODUCTS STORAGE PRODUCTS UrbanPondTM UrbanPondTM UrbanPondTM is a modular precast concrete underground storage system Configurations that mimics the function of ponds and open detention basins. Modules are UrbanPond is a modular precast concrete structure that can be assembled from one to several hundred modules, in various shapes available in 8x8 feet square or 8x16 rectangular options, giving designers and configurations to meet site-specific constraints and volume requirements. The 8x8 foot square modules are very versatile and more versatility to accommodate dense development, urban infill, or larger minimize pick weight and crane size requirements, while the 8x16 modules maximize installation efficiency, and dramatically reduce high-volume projects. The modular design can be placed under roadways, the amount of crane picks. parking lots and landscape areas in various shapes, sizes, and depths. In addition, a robust precast form allows it to be buried deeper without the need Frame and Cover with Risers to Grade for specialized backfill, increased wall thickness, or extra rebar reinforcement. For easy maintenance and inspection access. LinkUP Slab (8x8) LinkUP Slabs span the open cavities LinkUP Slab (8x16) like a checkerboard. Advantages LinkUP Slabs span the open cavities • Superior strength and load capacity • Higher void percentages and increased material efficiency for like a checkerboard. • Designed to meet H-20 loading requirements best-in-class cost per cubic foot storage • Can be installed deeper without the need to increase wall • 8x8 Modules are lighter weight and easier to install thickness or add additional rebar • 8x16 Modules reduce crane picks and maximize space • Every module drains down fully • LinkUP slabs can supplement for full modules, further decreasing cost and installation time Outflow Pipe Applications Inflow Pipe UrbanPond is engineered specifically for: • Detention with controlled discharge utilizing built-in outlet orifice structures. 8X16 MODULES 8X8 MODULES • Retention for long-term holding of runoff on-site to meet strict stormwater requirements. • Harvesting self-contained treatment and reuse of stormwater for irrigation and grey water needs. • Capture & Infiltration of runoff back into underlying native soils for recharge needs. • Treatment utilized as an underground extended detention basin or pond for advanced treatment of stormwater - integrates well with treatment train components (biofiltration, separation, etc.). • Flood Control of peak storm events to minimize downstream flooding and erosion. Perimeter Double Interior Double Single Single Interior Double Perimeter Double • Low Impact Development to maximize land use with underground storage - construct an urban infill without a pond at grade. Infiltration Treatment Trains Sizing Chart UrbanPond infiltration galleries are designed to maximize Bio Clean provides a full suite of treatment options for any type transfer of water for percolation into native soils and UrbanPond is available with inside heights ranging from 3 feet to 14 feet, in 6-inch increments. Single UrbanPond Modules are of site. By fully integrating the designs of each product in-house, groundwater recharge. The features include open floor spaces available with inside heights ranging from 3 feet to 7 feet, in 6-inch increments, and the Double UrbanPond Modules are stackable up Bio Clean treatment trains provide unmatched levels of water under the LinkUP Slabs and 30” diameter infiltration openings to 14 feet. The system’s internal offset leg configuration provides channel-less water distribution for stormwater entering and exiting quality. Ask us for a complete overview of each UrbanPond in each module. the system. Treatment Train combination and their unique benefits. UrbanPond Inside 8x8 Module Storage Volume 8x16 Module Storage Volume Height (ft.) (cu. ft.) (cu. ft.) 3 180 360 4 242 484 UPSTREAM & DOWNSTREAM TREATMENT 5 304 607 The DSBB Separator (pg. 24) can treat large flows, and captures trash, debris, and suspended solids, as well as hydrocarbons. The Modular Wetlands Linear 6 366 730 (pg. 6) is the only biofiltration product that can be placed downstream of a detention system. 7 428 854 Infiltration Openings 8 485 968 9 546 1091 Maintenance 10 608 1214 UrbanPond is designed to be easily accessed and maintained from finished surface via multiple 11 670 1338 access ports. Using a standard vacuum truck, each access point is conveniently located, as ports are strategically placed throughout the assembly. Modules can be modified to act as clear wells or 12 732 1461 pretreatment chambers for capturing trash, debris, and sediment. This consolidates maintenance 13 793 1584 requirements to a select few modules. Standard manholes, hinged manholes, and other access 14 855 1708 hatches are available. 4 ©2021 COPYRIGHT | BIO CLEAN ENVIRONMENTAL SERVICES, INC. COMPREHENSIVE STORMWATER SOLUTIONS GUIDE 5 BIOFILTRATION PRODUCTS BIOFILTRATION PRODUCTS Pre-filter Box BioMediaGREEN ® ® Modular Wetlands Linear Modular Wetlands Linear Individual Media Filters The Modular Wetlands® Linear is the only biofiltration system to utilize patented horizontal flow, allowing for a smaller footprint, higher treatment capacity, and a wide range of versatility. While most biofilters use little or Display Unit - 4x8 Vault Type Unit no pretreatment, the Modular Wetlands Linear incorporates an advanced pretreatment chamber that includes separation and pre-filter boxes. Horizontal Pre-Filter Box Biofiltration Media flow also gives the system the unique ability to adapt to the environment through Vertical Underdrain a variety of configurations, bypass orientations, and diversion applications. Flow Control Riser Advantages Pre-filter Box • Horizontal flow biofiltration • Flow control • Greater filter surface area • No depressed planter area • Pretreatment chamber • Auto drain down means no • Patented perimeter void area mosquito vector Inflow The Urban Impact For hundreds of years, natural wetlands surrounding our shores have played an integral role as nature’s stormwater treatment system. But as cities grow and develop, our environment’s natural filtration
Recommended publications
  • 2011RIC01 PP.Pdf
    1 2 3 4 Intended users: City and County public works Young engineers Developers Public officials and other non-engineers The Decision Tree distills information from many manuals and sources into one spot, and provides convenient documentation for how/why decisions are made on a project-by-project basis. Intended for use with projects for which there is no regional stormwater facility available. 5 BMP functions that may be required: -Sediment control -Nutrient removal -Volume reduction -Peak discharge rate control -Channel protection 6 7 Stormwater ponds are typically installed as an end-of-pipe BMP at the downstream end of a trunk storm sewer system or of a treatment train. Wet extended detention basins are the only type of pond that complies with the NPDES Permit. - Dry detention ponds are ones in which the outlet elevation matches or is slightly below that of the inlet elevation. All runoff that enters the pond is consider to leave the pond, but the outlet is restricted to temporarily store the runoff prior to discharge. There is no sediment storage, and sediment that was previously deposited often is carried downstream with larger storm events. Therefore, dry detention ponds provide rate control but no water quality benefits. - FtlFrequently, unlined wet d et enti on pon ds can dtbttdry out between storm even tifthts if they are constructed in sandy soil due to infiltration. These may still be considered to provide water quality benefits as the runoff has to pond up to a certain depth before it can discharge through the outlet pipe, allowing for sedimentation.
    [Show full text]
  • Bio Clean CPSTM
    Comprehensive Stormwater Solutions Guide 2021v2 CATALOG Storage | Biofiltration | Filtration Separation | Trash Capture | Specialty Filters Table of Contents Product Categories & Solutions Storage Products Page 4 - 5 UrbanPondTM ...........................................................................................................................................Page 4 Biofiltration Products Page 6 - 13 Modular Wetlands® Linear ................................................................................................................Page 6 WetlandMod® .....................................................................................................................................Page 10 Modular Wetlands® Fiberglass ...................................................................................................... Page 12 Filtration Products Page 14 - 19 Kraken® Filter .......................................................................................................................................Page 14 Water PolisherTM .................................................................................................................................. Page 18 For over 20 years, Bio Clean has proudly offered the industry's most dependable and effective stormwater solutions. We are constantly Separation Products Page 20 - 25 innovating, and our superior product line and engineering services SciClone® Separator .........................................................................................................................Page
    [Show full text]
  • Permanent BMP Operations & Maintenance Manual
    Permanent BMP Operations & Maintenance Manual STATE OF HAWAII, DEPARTMENT OF TRANSPORTATION, AIRPORTS DIVISION 400 Rodgers Boulevard, Suite 700 Honolulu, Hawaii 96819-1880 June 2018 Version 2 TABLE OF CONTENTS 1.0 INTRODUCTION............................................................................................................. 1 1.1 Requirements ............................................................................................................................. 2 1.2 Stormwater PBMP Inventory ................................................................................................... 3 1.2.1 Treatment PBMPs ................................................................................................................... 3 1.2.2 LID PBMPs ............................................................................................................................. 4 1.2.3 Source and Treatment Control Vegetative PBMPs ................................................................. 4 1.2.4 Source Control Evaporation Ponds and Infiltration Bed PBMPs ............................................ 5 2.0 TREATMENT PBMPs ..................................................................................................... 6 2.1 Oil Water Separators ................................................................................................................ 6 2.1.1 OWS Inspection Procedures.................................................................................................... 6 2.1.2 OWS Maintenance Procedures
    [Show full text]
  • Storm Water Low-Impact Development, Conventional Structural, And
    Storm Water Low-Impact Development, Conventional Structural, and Manufactured Treatment Strategies for Parking Lot Runoff Performance Evaluations Under Varied Mass Loading Conditions Robert M. Roseen, Thomas P. Ballestero, James J. Houle, Pedro Avelleneda, Robert Wildey, and Joshua Briggs Eleven storm water treatment strategies were evaluated for water quality many communities are curious about different treatment strategies. performance and storm volume reduction during rainfall–runoff events Many factors influence engineers, planners, resource managers, between September 2004 and August 2005. Evaluated treatment strategies and others in the selection of treatment strategies. The state of the included structural best management practices (BMPs) (swales, retention practice currently focuses predominantly on storm volume and ponds), low-impact development (LID) designs (treatment wetland, fil- peak flow reduction, with some attention also paid to sediment tration and infiltration designs), and manufactured BMPs (filtration, issues. This is evident by the widespread dominance of storm water infiltration, and hydrodynamic separators). Contaminant event mean ponds as treatment measures and swales as conveyance means. concentration, performance efficiency, and mass-based first flush were These systems continue to dominate the storm water landscape evaluated for storms with varying rainfall–runoff characteristics. Previ- despite volumes of quality research indicating that there are more ous research demonstrated that treatment performance of storm water effective treatment systems as well as the inclusion of these alter- control measures varies widely in response to site-specific contaminant nate designs in more recent storm water design manuals. A wide loading functions. For that reason, the devices were tested in parallel, with range of research on contaminant-specific removal strategies exists a single influent source providing uniform loading to all devices.
    [Show full text]
  • Rain/Stormwater Treatment Products List of Manufacturers & Products
    RAIN/STORMWATER TREATMENT PRODUCTS LIST OF MANUFACTURERS & PRODUCTS Rainwater Harvesting BMP Products BMPs, such as infiltration pits and cisterns, can be tailored to harvest, treat and use rain/stormwater for non-potable uses, such as landscape irrigation (sub-surface and spray), toilet/urinal flushing, and clothes washing. For more information on this strategy and a list of some vendors in the region, go to sustainablesm.org/runoff and click on left side, Rainwater Harvesting, then click Rain Barrel & Cistern Suppliers to learn more about the City’s program. Proprietary Products: Bord na Mona Environmental Products U.S. Inc., RainSava system, www.bnm-us.com Contech, www.Conteches.com, UrbanGreen Rainwater Harvesting system, single source solution with all components for a rainwater/stormwater use system. Oceansafe Inc., www.lithocrete.com/oceansafe Oldcastle Precast Inc., Storm Capture™ Reuse System, www.oldcastleprecast.com Ozcon Water Harvesting, Jason Holloway, owner, 510 375 6381, [email protected] www.ozconbuilding.com, specializing in modular underground water storage for landscape irrigation, as well as underground storm water management; eligible for LEED points and potentially huge savings on water bills. Infiltration Pit BMP Filler Products Visit the Code Requirements page at sustainablesm.org/runoff for more information on this strategy and a list of some vendors, or follow this direct link (or under Code Requirements, Infiltration Pit): smgov.net/uploadedFiles/Departments/OSE/Categories/Urban_Runoff/UR_Infiltration_Pit.pdf
    [Show full text]
  • BMP Maintenance Brochure
    WHY ARE BMPS NECESSARY, WHO ADDITIONAL INFORMATION Urban Stormwater MAINTAINS THEM, AND WHY DOES THE Links to the following resources can be found at: Best Management Practices CITY INPSECT THEM? http://alexandriava.gov/tes/DEQ/deqpublications.html (BMPs) Inspection Program The City of Alexandria Environmental • Alexandria Supplement to the Northern Virginia City of Alexandria, Virginia Management Ordinance implements the BMP Handbook City’s stormwater management program in • City of Alexandria BMP Maintenance Agreement A stormwater “Best Management Practice” compliance with the Virginia Stormwater (BMP) is a facility or structure that reduces Management Act and Chesapeake Bay • City of Alexandria Environmental Management the water quality impacts of stormwater Ordinance Preservation Act. These regulations runoff from developed areas. require the City to control the level of • City of Alexandria Master Plan Water Quality pollutants entering waterways such as the Management Supplement Potomac River and the Chesapeake Bay. Wet pond treating • “Stormwater Pollution and Management” brochure stormwater from a BMPs are designed to reduce pollutants shopping center such as sediments, oil, grease and nutrients. Examples of urban stormwater MAINTENANCE SERVICE PROVIDERS BMPs are wet and dry ponds, bioretention The City’s Division of Environmental Quality can areas, sand and storm filters, and provide BMP owners with a list of vendors who hydrodynamic separator devices. Regular have experience in maintaining stormwater maintenance is necessary for proper Trash inside an management facilities. overflow riser function and long-term viability. Please note that the City makes no representation or Ultra urban areas such as the City of warranties regarding the qualifications or suitability of Alexandria are densely developed areas any particular vendor, nor does a vendor's inclusion or with scarce open space and pervious non-inclusion on this list constitute any such surfaces.
    [Show full text]
  • Drainage Facility Cleaning Contractors (PDF), Also Found At
    Snohomish County Drainage Manual Volume VI Stormwater Facility Maintenance July 2020 Ecology Review DRAFT Snohomish County Drainage Manual Volume IV - Stormwater Facility Maintenance i Contents Introduction ................................................................................................................................................................1 Common Components 1. Catch Basins ............................................................................................................................................................5 2. Conveyance Storm Pipes ..................................................................................................................................... 11 3. Debris Barriers (e.g., Trash Racks) ....................................................................................................................... 13 4. Control Structure/Flow Restrictors ..................................................................................................................... 17 5. Facility Discharge Points ...................................................................................................................................... 24 6. Energy Dissipaters and Outfall Systems .............................................................................................................. 26 Stormwater Flow Control Facilities 7. Detention Ponds .................................................................................................................................................
    [Show full text]
  • HX Guide to the Downstream Defender®
    HX Guide to the Downstream Defender® Advanced Vortex Separation for Stormwater Treatment Stormwater Solutions www.hydro-int.com Contents Overview ...............................................................................................................2 I. Introduction to Advanced Vortex Separation ......................................................3 II. Removing Solids from Stormwater with Advanced Vortex Separation ..............4 III. Stormwater Treatment Applications for Advanced Vortex Separation ..............5 IV. The Principles of Conventional and Advanced Vortex Separation ...................6 V. The Evolution of Advanced Vortex Separation ..................................................8 VI. Basic Vortex Separators vs. Advanced Vortex Separators ..............................9 Further Information ..............................................................................................16 Overview Today, more manufactured stormwater treatment devices are available than ever before. The choices made by designers and specifiers of stormwater treatment devices have a huge impact on achieving stormwater treatment and water quality goals. Although having such a wide selection of stormwater treatment devices gives engineers and site designers more “tools” in their design toolbox, it is important to understand that not all stormwater treatment devices are the same. The purpose of this guide is to provide information about Advanced Vortex Separation technology and how its attributes make it well suited to a wide variety
    [Show full text]
  • Policy on the Use of Hydrodynamic Separators to Achieve Compliance with NPDES Provision C.3
    Donald P. Freitas Program Manager Policy on the Use of Hydrodynamic Separators to Achieve Compliance with NPDES Provision C.3 Hydrodynamic separators, when used as a sole method of stormwater treatment, do not meet the “maximum extent practicable” requirement for stormwater treatment effectiveness with regard to compliance with NPDES Provision C.3 in Contra Costa. The following types of facilities, if sized and designed as described in the Stormwater C.3 Guidebook, can meet the “maximum extent practicable” standard for stormwater treatment effectiveness: • Swales, planter boxes, bioretention areas, and other facilities using filtration through soil or sand (sized according to the flow-based criterion). • Dry wells, infiltration trenches, infiltration basins, and other facilities using infiltration to native soils (sized according to the volume-based criterion). • Extended detention basins, constructed wetlands or other facilities using settling (sized according to the volume-based criterion, with a detention time of 48 hours). Hydrodynamic separators, including vortex separators and continuous deflection separators (“CDS units”), are substantially less effective than any of the above-listed facilities for removing stormwater pollutants of concern. This difference in effectiveness can be inferred by comparing design criteria and mode of operation and by analyzing the relative capability of each type of facility to remove small particles. The difference in effectiveness can also be validated by reviewing available results of laboratory and field tests. Experience to date has shown swales, planter boxes, bioretention areas, or other effective treatment facilities can be successfully applied to Contra Costa development sites. Lack of space, in itself, is not a suitable justification for using a less effective treatment device since uses of the site and the site design can be altered as needed to accommodate a swale, planter box, bioretention area, or other effective BMP.
    [Show full text]
  • Hydrodynamic Separators As Stormwater Best Management Practices
    Report No. UT-04.15 HYDRODYNAMIC SEPARATORS AS STORMWATER BEST MANAGEMENT PRACTICES Final Report Prepared For: Utah Department of Transportation Research and Development Division Submitted By: Stantec Consulting Inc. Authored By: Karen Nichols, P.E. Kade Moncur Julie Howe April 2005 NOTICE This report is disseminated under the sponsorship of the Utah Department of Transportation. The contents of this report reflect the views of the authors, who are responsible for the facts and the accuracy of the data presented herein. UDOT RESEARCH & DEVELOPMENT REPORT ABSTRACT 1. Report No. UT-04.15 2. Government Accession No. 3. Recipient’s Catalog No. 4. Title and Subtitle 5. Report Date November 2004/Revised April 2005 Hydrodynamic Separators as Stormwater Best Management Practices 6. Performing Organization Code 7. Author(s) 9. Performing Organization Report No. Stantec Consulting Inc. Karen Nichols, P.E. Kade Moncur Julie Howe 9. Performing Organization Name and Address 10. Work Unit No. Stantec Consulting Inc. 3995 S. 700 E., Ste. 300 11. Contract No. 81FR0215 Salt Lake City, UT 84107 12. Sponsoring Agency Name and Address 13. Type of Report and Period Covered Utah Department of Transportation 4501 South 2700 West 14. Sponsoring Agency Code Salt Lake City, UT 84114-8410 15. Supplementary Notes 16. Abstract The use of hydrodynamic separators in the treatment of stormwater runoff for UDOT basins was evaluated. This evaluation included: 1) identifying potential stormwater pollutants of concern in transportation corridors, 2) identifying documented stormwater pollutant load estimation methods, 3) prepare a listing of available proprietary treatment BMPs, 4) develop a selection methodology for water quality BMPs, 5) prepare technical specifications for hydrodynamic separators.
    [Show full text]
  • Chapter 11- Mechanical Systems
    Iowa Storm Water Management Manual Design Standards Chapter 11- Mechanical Systems Chapter 11- Section 1 General Information for Proprietary Mechanical Systems Chapter 11- Section 2 Hydrodynamic Devices Chapter 11- Section 3 Gravity Separator Systems Chapter 11- Section 4 Catch Basins with Sumps and Catch Basin Inserts Chapter 11- Section 1 General Information for Proprietary Mechanical Systems A. Introduction A variety of manufactured structural control systems are available from commercial vendors designed to treat stormwater runoff and/or provide water quantity control. These systems include: Hydrodynamic systems such as gravity and vortex separators Filtration systems Catch basin media inserts Chemical treatment systems Package treatment plants Prefabricated detention structures Many proprietary systems are useful on small sites and space-limited areas where there is not enough land or room for other structural control alternatives. Proprietary systems can often be used in pretreatment applications in a treatment train. An example would be special systems for capture and removal of oils and petroleum products from storm runoff at industrial sites and fueling areas such as truck plazas. However, proprietary systems are often more costly than other alternatives and may have high maintenance requirements. Perhaps the largest difficulty in using a proprietary system is the lack of adequate independent performance data. Below are general guidelines that should be followed before considering the use of a proprietary commercial system. Note: It is the policy of this Manual not to recommend any specific commercial vendors for proprietary systems. However, this subsection is being included in order to provide communities with a rationale for approving the use of a proprietary system or practice in their jurisdictions.
    [Show full text]
  • Maintenance Guidance for Stormwater Hydrodynamic
    MAINTENANCE GUIDANCE FOR STORMWATER HYDRODYNAMIC SEPARATORS By JUNG-HOON KIM A Dissertation submitted to the Graduate School-New Brunswick Rutgers, The State University of New Jersey in partial fulfillment of the requirements for the degree of Doctor of Philosophy Graduate Program in Civil and Environmental Engineering written under the direction of Qizhong Guo and approved by ________________________ ________________________ ________________________ ________________________ New Brunswick, New Jersey October, 2014 © 2014 JUNG-HOON KIM ALL RIGHT RESERVED ABSTRACT OF THE DISSERTATION Maintenance Guidance for Stormwater Hydrodynamic Separators by JUNG-HOON KIM Dissertation Director: Professor Qizhong Guo The goal of this research is to develop effective maintenance procedures and quantify maintenance schedules for stormwater manufactured treatment systems, known as Hydrodynamic Separators (HDS). The HDS has started to be widely used with the purpose of removing pollutants from stormwater runoff and its use is expected to continue in the foreseeable future. Therefore, determining optimum maintenance procedures, intervals and costs is vital for their successful utilization. Information on characteristics and location of each installed HDS was collected and identified through a field monitoring and maintenance study. Based on this information, twelve (12) HDS were selected and three (3) data forms were developed: asset data form, inspection data form, and maintenance data form to help level the playing field, properly track the devices, and inspect and maintain the devices in a timely fashion and in a cost-effective way. Before initiation of the continuous monitoring program, stormwater and bottom sediment, the quantities of bottom sediment, oil, and buoyant debris in the devices were measured and the samples of trapped water and bottom sediment were taken for the quality analysis.
    [Show full text]