Tablet Management Rack 16 User's Guide

Table of Contents

Hazard Symbols Review ...... 2

Components ...... 2

Charging Set-up ...... 3-4

LED and Syncing ...... 4-5

Cleaning and Maintenance...... 6

Specifi cations ...... 6

Service and Warranty Information ...... 6

Reduce Reuse Recycle

Apple, iPad, iPhone, iPod, iPod touch, iTunes, and Macintosh are trademarks of Apple Inc., registered in the U.S. and other countries.

888-33-343-G-01 revB• 07/13 1 of 7 Hazard Symbols Review Symbol Signal Word Level of Hazard These symbols alert users of a safety condition that demands attention. All users should be able to A NOTE indicates important information that helps you NOTE recognize and understand the signifi cance of the fol- make better use of this product. lowing Safety Hazards if encountered on the product A CAUTION indicates either potential damage to or within the documentation. Children who are not CAUTION hardware or loss of data and tells you how to avoid the able to recognize and respond appropriately to Safety problem. Alerts should not use this product without adult A WARNING indicates either potential for property dam- supervision! WARNING age, personal injury, or death.

An Electrical indicates an impending electrical hazard ELECTRICAL which, if not avoided, may result in personal injury, fi re and/or death.

Components ABC

1x 4x 1x 1

1x 1x 4x 2

1 Plug in Power Cable a) Insert power cable into bottom of tower. b) Route cable through cable restraint.

888-33-343-G-01 revB• 07/13 2 of 7 2 Set-up racks and tower a) Insert tablets into racks and connect the cables that came with your . NOTE: If desired, attach cable identifi er . b) Connect USB Type A plug to tower and attach cable cover by snapping into place. c) Plug tower power cord into outlet. d) Bundle cables with velcro straps.

a a

a b

USB b type A

d

c

888-33-343-G-01 revB• 07/13 3 of 7 2 Tablet Charging

To begin charging the tablets, plug in the power cord.

The power cord is used to turn the power on and off. Charging occurs whenever the power cord is connected UNLESS a notebook USB cable is connected for syncing.

NOTE: The power cord acts as the connect/dis- connect device switching LED - Indicators power off and on. The socket outlet shall be installed near the equip- ment and shall be easily accessible.

Power Indicator – Communicates sync and charge status with the following signals:

Light Description Off No power to the tower. On - solid Tablets are charging. On - slow blink Computer is plugged into USB port and tablets are ready to sync or are syncing. On - fast blink Fault Status. Please make sure all cables are seated correctly and product is operating within specifi ed operating temperature. Can also indicate a failed USB cable. Contact Ergotron Customer Support if problem continues.

1-16 Individual Status Indicators (ISI) – Sequentially numbered LEDs (1 - 16) corresponding to each tablet in the tower: Light Description Green Fully charged. Amber Charging in progress. Off No device connected. (see note below)

NOTE: If tower is syncing all ISIs will be green. When used with the iPad (1st generation) and iPad 2, the ISI lights will continue to stay lit showing the color green indefi nitely after the unit is completely charged. When used with an iPad mini, and iPad with Retina Display (4th generation), or an iPad 3 and iOS 6.0 or later, the ISI will stay lit for approximately 15 minutes after the unit is completely charged. At this time, the iPad will turn off to conserve battery life, so the ISI will turn off also.

888-33-343-G-01 revB• 07/13 4 of 7 3 Tablet Syncing

Note: Complete the Tablet Charging instructions before starting the Syncing instructions. Tablets should be charged at least 50% before starting the syncing process. Tablets will only receive a 0.5A charge during the syncing process.

Tablets will mount as USB devices when the included USB cable is connected to a host notebook via the USB port on the back of the tower. To sync, follow the instructions for your particular third-party Mobile Device Management software. Files can also be transferred manually as the devices will be identifi ed as standard USB drives.

Apple Devices: Apple iPad, iPod touch, or iPhone devices will sync to a host Macintosh computer using third-party Mobile Device Management software, iTunes or Apple Confi gurator. To sync Apple devices using iTunes or Apple Confi gurator programs, Ergotron recommends using a Macintosh computer with the latest iTunes or Apple Confi gurator software. • Mac OS X v 10.5.8 or later • iTunes 9.1 or later (download from http://www.itunes.com/download) or Apple Confi gurator (download from the Mac ). Apple Confi gurator is only available for the Macintosh platform.

If you must use a PC with a Tablet Management product to sync your tablets, please check with the PC manufacturer to verify that it is designed to handle as least the following number of USB devices:

PC Capability Ergotron Product Number of USB Devices* Tablet Management Station 21 * For setup using iTunes, please see the Tablet Management Station web page for additional downloadable instructions.

USB type B

USB type A

888-33-343-G-01 revB• 07/13 5 of 7 Cleaning and Maintenance

Module and Equipment Electric Safety WARNING: Failure to observe the following Tablet Manage- There are specifi c risks associated with the use of equipment having ment Station Use Safety notices may result in serious personal power cables. You must be aware of, and avoid these risks when the injury or equipment damage. Tablet Management Station is located in close proximity to children.

WARNING: Failure to observe the following Electrical Safety Do not allow children to move the Tablet Management notices can result in fi re or death by electric shock. Station. • Do not allow anyone to sit, stand, or climb on the unit. • Do not block the fans and vent openings. To prevent over- Electrical cables can be hazardous. Misuse can result in fi re or heating, leave at least 127 mm (5-inch) clearance around fans death by electrical shock. and vents. • Double Pole / Neutral Fusing • Inspect power cables thoroughly before each use. • Do not use cables that are damaged. The unit is designed to be used indoors only. • Insert the plug completely into the outlet. • Do not use the unit for other than what has been noted in • Grasp the plug to remove from the outlet. this guide. • Do not unplug by pulling on the cable. • Do not place heavy objects on the unit surface or shelf. • Do not use excessive force to make connections. - The maximum weight capacity of each rack is 10 lbs • Do not plug the cable into an cable. (4.5 kg). • Do not remove, bend or modify any prongs or pins of cable. Moving the Tablet Management Station • Do not drive, drag or place objects over the cable. Before moving the unit: • Do not walk on the cable. 1. Disconnect the power cable from the wall. • Avoid overheating. Uncoil the cable and do not cover it with 2. Disconnect the USB cables from the tablets. any material. 3. Make sure the cables are wrapped and secure. • Do not run cable through doorways, holes in ceilings, walls or fl oors. Tablet Management Station Placement Keep the Tablet Management Station away from water. Observe these safety alerts for times when the Tablet Management • Do not use it when wet. Station is stationary: • Do not place the Tablet Management Station in close proxim- • Do not place Tablet Management Station on an object or ity to fl ammable liquids or gases. surface that cannot support its weight: 12.2 lbs (5.5 kg). • Do not run cables through doorways, holes in ceilings, walls, The unit cord acts as the connect/disconnect device switching or fl oors. power off and on. • Do not run cables across hallways, classrooms, or other areas where they will be walked on. • Do not leave unit unattended in areas where children have access.

TABLET MANAGEMENT STATION Input 100-240 V~, 2.0 A, 50/60 Hz This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired 35MR

operation. CAN ICES-3(A) / NMB-3(A). Product was placed UL 60950 on the market N13508 after 13 August 2005

827-068-01

888-33-343-G-01 revB• 07/13 6 of 7 Specifi cations

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. This Class A digital apparatus complies with Canadian ICES-003. / Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

Tower dimensions Power System 5.5 W x 8.8 D x 17.0 in H 100-240 V~, 2.0A, 50/60 Hz (140 x 224 x 207 mm) Environmental Rack dimensions Temperature range: 3.5 W x 8.5 D x 2.2 in H Operating 0° to 30°C (32° to 86°F) (89.8 x 216 x 55 mm) Storage -40° to 60°C (-40° to 140°F) Relative humidity (maximum): Rack weight limit Operating 10%–90% (non condensing) 10 lbs (4.5 kg) Storage 5%–95% (non condensing) Altitude (maximum): 2000 m (6,562 ft) Product weight 12.2 lb (5.5 kg) Compatibility: Made for LED status indicators (ISI) iPhone 5, iPhone 4S, iPhone 3GS, iPod touch (5th generation), iPod touch (4th Lights indicate power status and syncing activity generation), iPod touch (3rd generation), iPad mini, iPad with Retina Display (4th 17 LED lights generation), iPad (3rd generation), iPad 2, iPad

Cooling/ventilation Also compatible with most USB devices compliant with the USB 1.2 charging One 5-volt DC continuous operation fan standard including Samsung Galaxy Tab 2, products, Google Nexus 7, Viewsonic, ViewPad 7 and numerous phones by Samsung, HTC, , , Shipping weight Blackberry, Sony and LG. 14.9 lb (6.8 kg)

Service and Warranty

For Service Visit www.ergotron.com

www.ergotron.com NOTE: When contacting customer MADE IN CN 12-345-678 service, reference the serial number. 1234567-1234

888-33-343-G-01 revB• 07/13 7 of 7