Aurair B2 Pocket Guide
Total Page:16
File Type:pdf, Size:1020Kb
GUIDE Introduction System Requirements Hardware Overview Installation Requirements Thank you for purchasing the AurAir® Air OPTIONAL: Power CO2 WiFi ON/OFF • For indoor use only! Plug Value Mode Button Quality Monitor model Base-F or Pro-F. The • Device with WiFi capabilities like an AurAir Air Quality Monitor includes the • Type F Power Socket AurAir software, which allows you to smartphone, laptop or tablet WARNING: To reduce the risk of fire or electric manage your AurAir using a web browser. • Web Browser: Mozilla Firefox, Google shock, do not expose this product to rain or Chrome, or Microsoft Internet Explorer moisture. This pocket guide includes the warranty terms and is for use with the Base-F and Pro-F models. This guide will refer to both Hardware Installation models as the AurAir Monitor. The AurAir Network Topology Requirements Monitor is powered by the power socket. WARNING: FAILURE TO PROVIDE PROPER OPTIONAL: VENTILATION MAY CAUSE FIRE HAZARD, Packaged Contents KEEP AT LEAST 20 MM OF CLEARANCE • A DHCP-enabled network (for the AurAir Humidity Pressure (Base-F) Mode Config NEXT TO THE VENTILATION HOLES ON Monitor to obtain an IP address in case for Value AQI (Pro-F) Button Button THE BACK FOR ADEQUATE AIRFLOW. use with a cloud environment. Interface Description 1. Insert the AurAir Monitor into the type F • A management station computer running Power socket which is directly power socket. Power Plug an operating system like Microsoft Win- connected to the power plug. dows, Apple OS or Linux, capable of Measured CO2 value, refreshed every CO2 Value supporting a web browser. Located either minute. onsite and connected to the same Layer-2 Indicator which WiFi mode is selected, WiFi Mode network, or off-site connected to the same either AP mode or Client mode. Layer-2 network using a VPN. ON/OFF Button Switches display ON or OFF Measured humidity value, refreshed Humidity Value every minute. AurAir Skipping the optional WiFi-configuration POCKET • One AurAir Monitor Pressure (Base-F) Measured pressure value (Base-F) or Air Quality • This pocket guide NOTE: In case you do not connect the AurAir AQI (Pro-F) Air Quality Index (Pro-F). Monitor to your WiFi network: Even without Toggles display between numeric or Monitor GUIDE Mode Button configured WiFi connection, the AurAir Moni- graphic mode Model: Base-F TERMS OF USE: All AurAir Monitors must tor will function normally as a standalone Displays the used SSID and cloud use a standard power socket. device. Config Button Pro-F username and password Initial configuration Step 2 Embedded Web Interface / Device Dashboard If you click on the ‘settings’ link below the b. Select the WiFi ssid and password AurAir logo on the dashboard, the configurati- Step 1 Connect your iPhone or Android smartphone The AurAir Monitor can be set and controlled on page is opened. Click on the pulldown list next to the ‘Select or Laptop/Tablet to the AurAir WiFi AP. through a browser and WiFi connection of a SSID’ field, scroll and select the correct WiFi After the installation of the AurAir Monitor into network ssid. Enter the WiFi network SSID smartphone, laptop or tablet. General - The Configuration Page password if the WiFi network is password the power socket, following the installation Several examples of WiFi connection possibili- protected. After clicking on ‘submit’ to save the instructions, the power is automatically turned ties: When using Windows10, a webbrowser will Using the configuration page it is possible to entered values, the device will reboot to on. The AurAir Monitor will create its own WiFi open automatically the url: http://192.168.4.1 do a number of AurAir Monitor configuration configure. The initial startup time after reboot Access Point (AP). tasks like connecting the AurAir Monitor to a will be longer than normal due to the device If you are using IOS, please open the Safari WiFi network. connecting itself to the Internet. An active WiFi network with SSID AurAir-XX- browser and enter the url: http://192.168.4.1 YYYYYY will appear in your WiFi network list. c. Reboot the AurAir Monitor If you are using Android, please open the XX represents the specific modeltype and Click on the ‘Reboot’ button to reboot the version (Base or Pro), where ‘YYYYYY’ is an Chrome browser and enter the url: AurAir Monitor, after clicking on the button the alpha-numeric number. http://192.168.4.1 AurAir will immediately reboot itself. WARNING: If you do not see an After entering the url, press enter to access the d. Update the AurAir Monitor firmware active WiFi network with SSID like AurAir Monitor device home page. Click on the ‘Update button to update the AurAir-XX-YYYYYY, reset the device General - Home Page AurAir Monitor firmware, after clicking on the by unplugging the device, hold the on/off button the AurAir will immediately reboot itself. After reboot it will display firmware update button pressed and plug it into the wall socket The home page shows the Device Dashboard again. Hold the on/off button pressed until the messages, load the latest firmware from the that displays the main AurAir Monitor data like cloud (if newer then the current one) and screen goes off and on again, then release the The configuration page has the following CO2, humidity and pressure or AQI values. updates the AurAir Monitor firmware. button. After the reset the AurAir Monitor options: should return to AP mode. If not, please This home page will automatically refresh every This will ONLY work IF you have an active a. Set the administrator password repeat or contact our customer support. minute. connection the Internet! Enter the administrator password in the ‘Admin Cloud Dashboard Configuration (optional) Password’ field shown in the previous page and click on the submit button. After reboot, www.aurair.eu/aurair-cloud-manuals/ AurAir Customer Support you can only visit the home page and configu- ration page after entering the administrator NOTE: To be able to access historic values of For customer support visit: password. measured data in a browser, you must fully complete the configuration of the connection https://www.aurair.eu/support/ to the AurAir Cloud Dashboard. AurAir Base–F, Pro-F Safety Notices Limited Warranty Returns Disclaimer GENERAL 1. Read, follow, and keep these instructions. AURAIR B.V. ( “AURAIR”) warrants that the product(s) No Products will be accepted fot replacement or repair without EXCEPT FOR ANY EXPRESS WARRANTlES PROVIDED DIMENSIONS (LxWxH) 138.6mm x 54.1mm x 77.4mm furnished hereonder (the “Product(s)” shall be free from obtaining a Return MateriaIs Authorization (RMA) number from HEREIN, AURAIR , ITS AFFILIATES, AND lTS AND THEIR defects in material and workmanship for a period of one (1) AURAIR during the warranty period, and the Products being THIRD PARTY DATA, SERVICE, SOFTWARE AND HARD- WEIGHT 186 gram 2. Comply to all warnings. year trom the date of shipment by AURAIR under normal use and operation. received at AURAIR facility freight prepaid in accordance with WARE PROVIDERS HEREBY DISCLAIM AND MAKE NO POWER INPUT/ 230VAC, 50Hz 3. Only use attachments/accessories specified by the the RMA process of AURAIR. Products returned without an RMA OTHER REPRESENTATION OR WARRANTY OF ANY manufacturer . AURAIR sole and exclusive obligation and liability under the number will not be processed and will be returned freight KIND,EXPRESS, IMPLIED OR STATUTORY. INCLUDING, MAXIMUM LOAD 3500W foregoing warranty shall be for AURAIR, at its discretion, to collector subject to disposal. lnformation on the RMA process BUT NOT LIMITED TO, REPRESENTATIONS, GUARAN- WARNING: Do not use this product in location repair or replace any Product that fails to conform to the and obtaining an RMA number can be found at: www.aurair.eu/ TEES, OR WARRANTlES OF MERCHANTABILITY. ACCU- above warranty during the above warranty period. The POWER USAGE 1.5W (idle) ~ 3W (Max) that can be submerged by water. expense of remaval and reinstallation of any Product is not support/warranty. RACY, QUALITY OF SERVICE OR RESULTS, AVAILABILI- included in this warranty. The warranty period of any repaired TY, SATISFACTORY QUALITY, LACK OF VIRUSES, QUIET OPERATING TEM- Range: 0 ~ 50 degrees C WARNING: Avoid using this product during an or replaced Product shall not extend beyond its original term. Limitation of Liability ENJOYMENT, FITNESS FOR A PARTICULAR PURPOSE electrical storm. There may be a remote risk AND NON-INFRINGEMENT AND ANY WARRANTlES RELATIVE HUMIDITY Range: 0 ~ 100 %RH (NOT suitable for wet Warranty Conditions ARISING FROM ANY COURSE OF DEALING, USAGE OR areas!) of electric shock from lightning. EXCEPT TO THE EXTENT PROHIBITED BY LOCAL LAW, IN TRADE PRACTICE IN CONNECTION WITH SUCH PRO- NO EVENT WlLL AURAIR OR lTS SUBSIDIARIES, AFFILI- DUCTS AND SERVICES. BUYER ACKNOWLEDGES THAT SOCKET Type F The above warranty does not apply if the Product: ATES OR SUPPLIERS BE LIABLE FOR DIRECT, SPECIAL, Electrical Safety lnformation NEITHER AURAIR NOR lTS THIRD PARTY PROVIDERS INCIDENTAL, CONSEQUENTAL OR OTHER DAMAGES I. has been modified and/or altered, or an addition made CONTROL BUYER'S EQUIPMENT OR THE TRANSFER OF PLUG Type F (INCLUDING LOST PROFIT, LOST DATA, OR DOWNTIME 1. Compliance is required with respect to vol tage, frequency, thereto, except by AURAIR, or AURAIR authorized DATA OVER COMMUNICATIONS FACILITIES, INCLUDING COSTS), ARISING OUT OF THE USE, INABILITY TO USE, and current requirements indicated on the manufacturer's representatives, or as approved by AURAIR in writing; THE INTERNET, AND THAT THE PRODUCTS AND SERVI- IP CLASS IP40 label. Connection to a different power source than those OR THE RESULTS OF USE OF THE PRODUCT, WHETHER- CES MAY BE SUBJECT TO LIMITATlONS, INTERRUPTI- specified may result in improper operation, damage to the II.