Poster Abstracts

Total Page:16

File Type:pdf, Size:1020Kb

Poster Abstracts POSTER ABSTRACTS American Glaucoma Society 30th Annual Meeting 3 AGS 2020 Poster Schedule Poster abstracts are available online at www.americanglaucomasociety.net. THURSDAY, FEBRUARY 27 7:00 AM – 8:00 AM Poster Presentation Session (1-46) 7:00 AM – 5:00 PM Poster viewing (1-46) FRIDAY, FEBRUARY 28 7:00 AM – 8:00 AM Poster Presentation Session (47-104) 7:00 AM – 5:00 PM Poster viewing (47-104) SATURDAY, FEBRUARY 29 7:00 AM – 8:00 AM Poster Presentation Session (105-151) 7:00 AM – 4:05 PM Poster viewing (105-151) THURSDAY, FEBRUARY 27 Minimally Invasive Glaucoma Surgery (MIGS) POSTER # TITLE PRESENTER NAME 1 Outcomes of Iridex MicroPulse P3 (MP3) with Higher-Than-Usual Settings for the Nandita Anand, MD Management of Elevated Eye Pressure 2 Sustained 5-Year Safety and IOP Outcomes in Open-Angle Glaucoma Subjects Jason Bacharach, MD Treated with Trabecular Micro-Bypass Stents (iStent Inject) 3 Outcomes of Combined Cyclophotocoagulation with Trabecular Meshwork Jonathan Buttram, MD Bypass Minimally Invasive Glaucoma Surgeries in the Treatment of Advanced Open-Angle Glaucoma 4 Long-term Efficacy of Minimally Invasive Glaucoma Surgery in Uveitic and Rebecca Chen, MD Steroid-responsive Glaucoma 5 Clinical Outcomes Following a Novel Technique of Sub-tenon XEN Gel Stent Anna Do, MD Implantation with Conjunctival Peritomy 6 12-Month Outcomes of Stand-Alone Excisional Goniotomy in Mild to Severe Mohammed ElMallah, MD Open-Angle Glaucoma 7 Comparison of Clinical Outcomes After Micropulse and Continuous Wave Monica Ertel, MD, PhD Transscleral Cyclophotocoagulation 8 Ab Interno Canaloplasty Combined with Phacoemulsification and Ab Interno Consuelo Gajardo Menzel, MD Canaloplasty Stand-alone Procedure In Medically Controlled Glaucoma 9 Survey of Microinvasive Glaucoma Surgery (MIGS) and Other Glaucoma Surgical Kevin Halenda, MD Experience Among United States Ophthalmology Residents 10 The Effect of Iris Color on Outcomes of Micropulse Cyclophotocoagulation Sara Hooshmand, BS (mTSCPC) in Adult Glaucoma Patients at One Year 11 Initial Outcomes of Combined Phacoemulsification with Juan Carlos Izquierdo Endocyclophotocoagulation with and without Ab Interno Trabeculotomy in Villavicencio, MD Open Angle Glaucoma 12 Effect of Pre-randomization Glaucoma Medication Washout on Intraocular Thomas Johnson, MD, PhD Pressure in the COMPASS and HORIZON Trials 4 Poster Schedule American Glaucoma Society 30th Annual Meeting 13TIME Three Year Follow-UpEVENT of/ TITLE Ab-Interno Canaloplasty (ABiC) with iTrack Catheter: MahmoudLOCATION Khaimi, / SPEAKER MD A Large, Single-Center Retrospective Review 14 Five-Year Outcomes of Two 2nd-Generation Trabecular Micro-Bypass Stents Albert Khouri, MD (iStent Inject) Combined with Travoprost in Open-Angle Glaucoma on 2 Preoperative Medications 15 The Efficacy of Two Trabecular Micro-Bypass Stents with Phacoemulsification Michael Lawson, MD Surgery Compared to Trabeculectomy with Phacoemulsification Surgery 16 Long-Term Outcomes of iStent Trabecular Micro-Bypass Stenting with Cataract Richard Lehrer, MD Surgery Including VF, OCT and Disease Progression – Real-world Case Series 17 XEN Gel Stent Insertion in Patients with Failed Trabeculectomy: Lindsay Machen, MD A Novel Surgical Approach 18 Goniotomy Using the Kahook Dual Blade in Severe and Refractory Glaucoma: Kaweh Mansouri, MD, MPH, One Year Outcomes FEBO 19 Efficacy and Safety of Micropulse Transscleral Cyclophotocoagulation (M-TSCPC) Rodolpho Matsumoto, MD in Uncontrolled Mild to Severe Glaucoma: A Single Center Canadian Study 20 Retrospective Study: Outcomes of Ab Interno Hydrus Microstent with William Mccollum, MD Concomitant Cataract Surgery 21 Mapping the Aqueous Veins Outflow System and Its Relation to Canaloplasty Sayoko Moroi, MD, PhD Surgery Outcomes 22 Demographic Differences in the Effectiveness of Minimally Invasive Glaucoma Mildred Olivier, MD Surgery (MIGS) Devices/Procedures 23 Outcomes of Ab Interno Gelatin Microstent with MMC Using Targeted Jeb Ong, MD Supra-tenon’s Placement 24 Short Term Outcomes of a Trans-scleral Gelatin Stent: Ab Interno vs Ab Externo Joseph Panarelli, MD Stent Placement 25 Outcomes of Ab Interno Versus Ab Externo XEN Gel Stent Implantation Robert Purgert, MD, PhD 26 Current State of Micro-invasive Glaucoma Surgeries in Ophthalmology Mary Qiu, MD Residency Education 27 Reduction in Incisional Glaucoma Surgery After 4-Years with a Schlemm’s Canal Douglas Rhee, MD Microstent Combined with Cataract Surgery for Treatment of Primary Open Angle Glaucoma 28 A Single-Surgeon Interventional Case Series of 80 Ab Interno XEN Gel Stent David Rooney, MD Implantations 29 Surgical Outcomes of Gonioscopy-Assisted Transluminal Trabeculotomy Ali Salimi, MSC (GATT) with and without Concomitant Cataract Surgery in Young and Middle-aged Adults 30 Outcomes of the iStent Trabecular Micro-bypass Implant: 3-Year Follow-up Saba Samet, MD 31 Real-world Experience with 2nd Generation Trabecular Micro-bypass Stents Steven Sarkisian, MD (iStent inject) Implanted in Conjunction with Phacoemulsification 32 Outcomes of Primary Cyclophotocoagulation Using the Slow Coagulation Mohamed Sayed, MD Continuous Wave Settings: One Year Results 33 Outcomes of Phacoemulsification Combined with Endocyclophotocoagulation & Anthony Scott, MHI Kahook Dual Blade Goniotomy 34 Comparison of Clinical Outcomes after XEN Gel Stent and EX-PRESS Glaucoma Ari Stoner, BS Drainage Device 35 Circumferential Viscodilation Ab Interno Combined with Phacoemulsification Nathaniel Tracer, BA for Treatment of Open-Angle Glaucoma: 12-Month Outcomes 36 PRESERFLO MicroShunt in the Surgical Management of Glaucoma Secondary Jing Wang, MD to Uveitis 37 Early Results of 2nd Generation Trabecular Micro-Bypass Stents (iStent inject®) Tyler Wickas, BS with Cataract Surgery in a Real-World Setting American Glaucoma Society 30th Annual Meeting Poster Schedule 5 38TIME To GATT or Half-GATT?EVENT / TITLE Comparison of Ab Interno Circumferential 360 Degree AliceLOCATION Williams, MD / SPEAKER Trabeculotomy vs 180 Degree Trabeculotomy in the Treatment of Glaucoma 39 Pre-operative Predictors of Gonioscopy-Assisted Transluminal Trabeculotomy Connie Wu, MD (GATT) Outcomes 40 Surgical Outcomes of XEN45 Gel Stent Placement with MMC for Treatment of Tina Xia, MD Glaucoma at a Single Tertiary Medical Center 41 Safety and Short-term Efficacy Outcomes of Using the OMNI® Device in Eyes Arkadiy Yadgarov, MD with Primary Open Angle Glaucoma Undergoing Cataract Extraction 42 Outcomes of Ab Interno Placement Versus Ab Externo Transconjunctival Lucy Yuan, BS Placement of Xen 45 Gel Stents 43 A Retrospective Outcome Analysis of XEN Gel Stent Joseph Zimmer, BS 44 Observational Case Series Evaluating Outcomes of a Single Surgeons First 100 Mark Gallardo, MD Cases of the Xen45 Gel Stent Implanted Via an Ab-Interno or Ab-Externo Approach for the Managment of Open Angle Glaucoma 45 Second-Generation Trabecular Micro-Bypass Stents (iStent Inject®) with Cataract Michael Hopen, MD Surgery in Open-Angle Glaucoma: Single-Surgeon Outcomes 46 A Retrospective Study of Cataract Surgery Combined with Ab-Interno Matthew Porter, MD Canaloplasty Using the iTrack TM Catheter and a Hydrus Microstent in Patients with Primary OpenAngle Glaucoma FRIDAY, FEBRUARY 28 Traditional Surgery, Sustained Delivery, New Drugs, IOP Evaluation POSTER # TITLE PRESENTER NAME 47 Uveitic Glaucoma: A 10-year Retrospective and Risk Factors for Requiring Daniela Alvarez-Ascencio, MD Filtering Surgery 48 Incidence of Corneal Transplant Graft Failure with Glaucoma Drainage Device Cara Capitena Young, MD Placed in the Anterior Chamber Compared to the Ciliary Sulcus 49 Early Surgeon Experience with a New Valveless Glaucoma Drainage Device Peter Chang, MD 50 Factors Associated with Trabeculectomy Failure Following Phacoemulsification Paul Cotran, MD 51 Long-Term Outcomes of Primary Trabeculectomy Versus Combined Jose Davila, MD Phacoemulsification-Trabeculectomy Using Automated Electronic Health Record Data Extraction 52 The Relationship of Patient Distance to Postoperative Care on Follow-up Ian Funk, BA Attrition and Glaucoma Surgery Outcomes 53 Direct Cyclopexy for Postraumatic Cyclodyalisis: Clinical Characteristics Jorge Eduardo Gamiochipi and Outcomes Arjona, MD 54 Ahmed Versus Baerveldt Glaucoma Drainage Device in Uveitic Glaucoma Allen Ganjei, BS 55 Progression to No Light Perception Vision is Equally Likely with Valved and Aakriti Garg Shukla, MD Non-Valved Tube Shunts in Neovascular Glaucoma 56 Surgical Outcomes Assessment of Glaucoma Tube Shunt Implantation: Xinxing Guo, MD, PhD An Electronic Health Records Analysis 57 Safety and Efficacy Outcomes of Modern Trabeculectomy with Low Dose Injected Sumeet Gupta, MD Mitomycin C with Planned Laser Suturelysis 58 Three Year Outcomes of Trabecular Micro-Bypass Stents (iStent Inject) Stratified Fritz Hengerer, MD, PhD by Prior Glaucoma Surgery 59 Diplopia in Patients with Baerveldt 250 and 350, and Ahmed FP7 Glaucoma Khin Kilgore, MD, JD Drainage Devices 6 Poster Schedule American Glaucoma Society 30th Annual Meeting 60TIME The RequirementEVENT of Additional / TITLE Glaucoma Surgery After Glaucoma Drainage FelixLOCATION Kung, BA / SPEAKER Device Surgery in Patients with Open-angle, Angle-closure, Neovascular, and Pseudoexfoliative Glaucoma 61 Higher Rates of Recurrent Tube Exposure with Anti-VEGF Therapy in Patients Katy Liu, MD, PhD with Macular Degeneration 62 Predictive Factors for Microcystic Macular Edema in Glaucoma Golnoush Sadat Mahmoudi Nezhad, MD-MPH 63 Risk Factors for Glaucoma Drainage Device Failure in
Recommended publications
  • Deep Learning Analysis of Eye Fundus Images to Support Medical Diagnosis
    Deep learning analysis of eye fundus images to support medical diagnosis Oscar Juli´anPerdomo Charry Universidad Nacional de Colombia Departamento de Ingenier´ıade Sistemas e Industrial Bogot´a,Colombia 2020 Deep learning analysis of eye fundus images to support medical diagnosis Oscar Juli´anPerdomo Charry Thesis submitted as requirement to obtain the title of: PhD. in Systems and Computer Engineering Advisor: Fabio A. Gonz´alez,Ph.D. Universidad Nacional de Colombia Departamento de Ingenier´ıade Sistemas e Industrial Bogot´a,Colombia 2020 Deep learning analysis of eye fundus images to support medical diagnosis Oscar Perdomo Dedication To my muse and beautiful wife Ana To my parents Alvaro´ and Isabel To my brothers Kike and Cesar Abstract Machine learning techniques have been successfully applied to support medical decision making of cancer, heart diseases and degenerative diseases of the brain. In particular, deep learning methods have been used for early detection of abnormalities in the eye that could improve the diagnosis of different ocular diseases, especially in developing countries, where there are major limitations to access to specialized medical treatment. However, the early detection of clinical signs such as blood vessel, optic disc alterations, exudates, hemorrhages, drusen, and microaneurysms presents three main challenges: the ocular images can be affected by noise artifact, the features of the clinical signs depend specifically on the acquisition source, and the combination of local signs and grading disease label is not an easy task. This research approaches the problem of combining local signs and global labels of different acquisition sources of medical information as a valuable tool to support medical decision making in ocular diseases.
    [Show full text]
  • Usage of Laser Induced Bubbles for Measuring Intraocular Eye Pressure
    ALTIND Fatih Fatih İŞ USAGE OF LASER INDUCED BUBBLES USAGE OF LASER INDUCED BUBBLES FOR MEASURING MEASURING FOR BUBBLES INDUCED LASER OF USAGE FOR MEASURING INTRAOCULAR EYE PRESSURE INTRAOCULAREYE A THESIS SUBMITTED TO THE DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING AND THE GRADUATE SCHOOL OF ENGINEERING AND SCIENCE OF PRESSURE ABDULLAH GUL UNIVERSITY IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF MASTER IN SCIENCE By Fatih ALTINDİŞ AGU 2017 December 2017 i USAGE OF LASER INDUCED BUBBLES FOR MEASURING INTRAOCULAR EYE PRESSURE A THESIS SUBMITTED TO THE DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING AND THE GRADUATE SCHOOL OF ENGINEERING AND SCIENCE OF ABDULLAH GUL UNIVERSITY IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF MASTER IN SCIENCE By Fatih ALTINDİŞ December 2017 ii SCIENTIFIC ETHICS COMPLIANCE I hereby declare that all information in this document has been obtained in accordance with academic rules and ethical conduct. I also declare that, as required by these rules and conduct, I have fully cited and referenced all materials and results that are not original to this work. Fatih ALTINDIŞ iii REGULATORY COMPLIANCE M.Sc. thesis titled USAGE OF LASER INDUCED BUBBLES FOR MEASURING INTRAOCULAR PRESSURE has been prepared in accordance with the Thesis Writing Guidelines of the Abdullah Gül University, Graduate School of Engineering & Science. Prepared By Advisor Fatih ALTINDIŞ Prof. Bülent YILMAZ Head of the Electrical and Computer Engineering Program Assoc. Prof. V. Çağrı GÜNGÖR iv ACCEPTANCE AND APPROVAL M.Sc. thesis titled USAGE OF LASER INDUCED BUBBLES FOR MEASURING INTRAOCULAR PRESSURE and prepared by Fatih Altındiş has been accepted by the jury in the Electrical and Computer Engineering Graduate Program at Abdullah Gül University, Graduate School of Engineering & Science.
    [Show full text]
  • Factors Affecting Measurements of Iop Using Non-Contact Eye Tonometer
    Strojnícky časopis – Journal of MECHANICAL ENGINEERING, VOL 70 (2020), NO 2, 133 - 140 FACTORS AFFECTING MEASUREMENTS OF IOP USING NON-CONTACT EYE TONOMETER RYBÁŘ Jan1, HUČKO Branislav2*, ĎURIŠ Stanislav1, PAVLÁSEK Peter3,1, CHYTIL Miroslav3, FURDOVÁ Alena4, VESELÝ Pavol4,5 1Slovak University of Technology in Bratislava, Faculty of Mechanical Engineering, Institute of Automation, Measurement and Applied Informatics, Mýtna 36, 811 07 Bratislava, Slovakia 2Slovak University of Technology in Bratislava, Faculty of Mechanical Engineering, Institute of Applied Mechanics and Mechatronics, Nám. slobody 17, 812 31 Bratislava, Slovakia, e – mail: [email protected] 3Slovak Metrology Institute, Karloveská 63, 842 55 Bratislava 4, Slovakia 4University Hospital Bratislava, Ophthalmology Clinic LFUK and UNB, Ružinovská 6, 826 06 Bratislava, Slovakia 5VESELY Očná klinika, s.r.o, Karadžičova 16, 821 08Bratislava, Slovakia Abstract: The objective measurement of intraocular pressure (IOP) represents the identification of the symptoms of some diseases, e.g. glaucoma. This objective measurement can only be achieved by correct calibration of tonometers. Today, there is no uniform methodology for this calibration. Therefore, we introduce potential sources of error and try to quantify their contributions in this paper. Subsequently, a calibration standard containing an artificial cornea with similar properties to the human one should be designed. KEYWORDS: measurement, intraocular pressure, non-contact eye tonometer, uncertainties and factors 1 Introduction Correct metrological assurance in ocular tonometry is very important in the prevention of such insidious diseases as glaucoma. Specifically, to ensure accurate measurement of intraocular pressure with eye tonometer is the goal of our efforts. The most commonly used type of ophthalmological tonometers in ophthalmic practice are those that measure eye pressure using contactless methods.
    [Show full text]
  • Effect of Macular Hole Volume on Postoperative Central Macular Thickness O Efeito Do Volume De Buraco Macular Da Espessura Macular Central Pós-Operatória
    ORIGINAL ARTICLE Effect of macular hole volume on postoperative central macular thickness O efeito do volume de buraco macular da espessura macular central pós-operatória TAYLAN OZTURK1, EYYUP KARAHAN2, DUYGU ER1, MAHMUT KAYA1, NILUFER KOCAK1, SULEYMAN KAYNAK1 ABSTRACT RESUMO Purpose: To evaluate the association between macular hole volume (MHV) and Objetivo: Avaliar a relação entre o volume do buraco macular (MHV) e a espessura postoperative central macular thickness (CMT) using spectral-domain optical macular central pós-operatória (CMT) por meio da tomografia de coerência óptica coherence tomography (SD-OCT). de domínio espectral (SD-OCT). Methods: Thirty-three eyes of 30 patients with a large full-thickness idiopathic Método: Trinta e três olhos de 30 pacientes com buracos maculares idiopáticos de macular hole with or without vitreomacular traction who underwent surgical espessura total grandes, com ou sem tração vitreorretiniana, que foram submetidos a intervention were included in this cross-sectional study. Complete ophthalmo- intervenção cirúrgica foram incluídos neste estudo transversal. O exame oftalmo- logical examination, including SD-OCT, was performed for all participants du- lógico completo, incluindo SD-OCT foi realizado nas visitas pré e pós-operatórias ring the pre- and postoperative visits. MHV was preoperatively measured using de todos os participantes. MHV foi medido a partir da imagem de SD-OCT pré- SD-OCT, which captured the widest cross-sectional image of the hole. For normal -operatória que capturou a imagem mais larga da secção transversal do buraco. distribution analysis of the data, the Kolmogorov-Smirnov test was performed, Após a análise distribuição nomral da população do estudo ter sido realizada com and for statistical analyses, chi-square, Student’s t-test, Mann-Whitney U test, and o teste Kolmogorov-Smirnov, os testes de qui-quadrado, t de Student, Mann-Whitney Pearson’s correlation coefficient test were performed.
    [Show full text]
  • Clinical Studies Articles Testimonials Feline Breeds Predisposed to Glaucoma
    DNA CLINICAL STUDIES ARTICLES TESTIMONIALS FELINE BREEDS PREDISPOSED TO GLAUCOMA Persians Siamese Domestic Short-Hair CANINE BREEDS PREDISPOSED TO GLAUCOMA Afghan Dalmatian Norwich Terrier Akita Dandie Dinmont Terrier Pekingese Alaskan Malamute English Cocker Spaniel Pembroke Welsh Corgi American Eskimo Dog English Springer Spaniel Petit Basset Griffon Vendéen Australian Cattle Dog Entlebucher Mountain Dog Poodle (all varieties) Basset Hound Flat-coated Retriever Pug Beagle Fox Terrier (all varieties) Saluki Bedlington Terrier Golden Retriever Samoyed Bichon Frise Great Dane Schnauzer (all varieties) Blue Healer Greyhound Scottish Terrier Border Collie Irish Setter Sealyham Terrier Boston Terrier Italian Greyhound Shar Pei Bouvier des Flanders Brittany Keeshond Shiba Inu Brittany Labrador Retriever Shih Tzu Bullmastiff Lakeland Terrier Siberian Husky Cairn Terrier Maltese Skye Terrier Cardigan Welsh Corgi Manchester Terrier Tibetan Terrier Chihuahua Miniature Pinscher Welsh Springer Spaniel Chow Chow Newfoundland Welsh Terrier Cocker Spaniel Norfolk Terrier West Highland Terrier Dachshund Norwegian Elkhound ICARE TONOVET TECHNICAL INFORMATION TYPE: TV01 DIMENSIONS: 13 – 32 mm (W) * 45 – 80 mm (H) * 230 mm (L) WEIGHT: 155 g (without batteries), 250 g (4 x AA batteries) POWER SUPPLY: 4 x AA batteries DISPLAY RANGE: 0-99 mmHg ACCURACY OF DISPLAY: 1 DISPLAY UNIT: Millimeter mercury (mmHg) STORAGE/TRANSPORTATION ENVIRONMENT: Temperature +5 to +40 °C Rel. humidity 10 to 80% (without condensation) The device conforms to CE regulations. For veterinary use only. There are no electrical connections from the tonometer to the patient. The device has B-type electric shock protection. 2 WWW.ICARETONOMETER.COM FAQ IS THE TONOVET MEASUREMENT PAINLESS? CAN SAME PROBE BE USED TO MEASURE BOTH Measurement is painless, the light-weight probe touches EYES OF ONE PATIENT? the cornea momentarily and very gently, and most pa- Yes, same probe can be used to measure both eyes of one tients don’t even notice the measurement.
    [Show full text]
  • Echographic Evaluation of a Subconjunctival Cystic Lesion
    Hindawi Case Reports in Ophthalmological Medicine Volume 2017, Article ID 5401850, 3 pages https://doi.org/10.1155/2017/5401850 Case Report Echographic Evaluation of a Subconjunctival Cystic Lesion Maddalena De Bernardo,1 Gennarfrancesco Iaccarino,2 Valeria Russo,1 and Nicola Rosa1 1 DepartmentofMedicineandSurgery,UniversityofSalerno,Salerno,Italy 22ndUniversityofNaples,Naples,Italy Correspondence should be addressed to Nicola Rosa; [email protected] Received 27 February 2017; Accepted 3 April 2017; Published 12 April 2017 Academic Editor: Claudio Campa Copyright © 2017 Maddalena De Bernardo et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Migration of intraocular silicone oil, used in the treatment of complicated retinal detachment, has been rarely described, but when it happens it can arise with a differential diagnosis with scleral buckling extrusion, tumor, dermoid, ocular cysticercosis, and abscess. The presence of silicone oil in the eye gives very ugly echographic pictures, but these kinds of pictures can bevery useful in making a differential diagnosis in the above-mentioned cases. A 39-year-old white female complained of the presence of conjunctival hyperemia and tearing in the right eye (RE); her visual acuity was hand motion, and the intraocular pressure was 14 mmHg. In the upper nasal quadrant a dome shaped lesion was detected. Due to the lens opacities, the patient underwent an echographic examination, which revealed the presence of silicon oil both in the vitreous chamber and in a large subconjunctival space, corresponding to the lesion. This article in addition provides a possible explanation of such cystic formation and discusses the risk factors and the role of the echographic examination in such cases.
    [Show full text]
  • Disinfection of Tonometers a Report by the American Academy of Ophthalmology
    Ophthalmic Technology Assessment Disinfection of Tonometers A Report by the American Academy of Ophthalmology Anna K. Junk, MD,1 Philip P. Chen, MD,2 Shan C. Lin, MD,3 Kouros Nouri-Mahdavi, MD,4 Sunita Radhakrishnan, MD,5 Kuldev Singh, MD, MPH,6 Teresa C. Chen, MD7 Objective: To examine the efficacy of various disinfection methods for reusable tonometer prisms in eye care and to highlight how disinfectants can damage tonometer tips and cause subsequent patient harm. Methods: Literature searches were conducted last in October 2016 in the PubMed and the Cochrane Library databases for original research investigations. Reviews, non-English language articles, nonophthalmology articles, surveys, and case reports were excluded. Results: The searches initially yielded 64 unique citations. After exclusion criteria were applied, 10 labo- ratory studies remained for this review. Nine of the 10 studies used tonometer prisms and 1 used steel discs. The infectious agents covered in this assessment include adenovirus 8 and 19, herpes simplex virus (HSV) 1 and 2, human immunodeficiency virus 1, hepatitis C virus, enterovirus 70, and variant Creutzfeldt-Jakob disease. All 4 studies of adenovirus 8 concluded that after sodium hypochlorite (dilute bleach) disinfection, the virus was undetectable, but only 2 of the 4 studies found that 70% isopropyl alcohol (e.g., alcohol wipes or soaks) eradicated all viable virus. All 3 HSV studies concluded that both sodium hypochlorite and 70% isopropyl alcohol eliminated HSV. Ethanol, 70% isopropyl alcohol, dilute bleach, and mechanical cleaning all lack the ability to remove cellular debris completely, which is necessary to prevent prion transmission. Therefore, single-use tonometer tips or disposable tonometer covers should be considered when treating patients with suspected prion disease.
    [Show full text]
  • Applanation Tonometry: a Comparison of the Perkins Handheld and Goldmann Slit Lamp-Mounted Methods
    Clinical Ophthalmology Dovepress open access to scientific and medical research Open Access Full Text Article ORIGINAL RESEARCH Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods R Arora1 Purpose: To compare intraocular pressure (IOP) measurements, taken using Perkins H Bellamy2 applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). MW Austin2 Methods: 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was 1University Hospital of Southampton, Southampton, Hampshire, 2Singleton measured, for all subjects, and the data used in statistical analysis. The comparability of results Hospital, Abertawe Bro Morgannwg given by the two instruments was evaluated using the Bland–Altman method. University Health Board, Swansea, IOP measurements for 100 eyes were obtained (range: 10–44 mmHg). The mean GAT Wales, UK Results: reading was 21.63 mmHg, with standard deviation (SD) 5.69 mmHg. The mean PAT reading was 21.40 mmHg, with SD 5.67 mmHg. The mean difference between readings from Goldmann For personal use only. versus Perkins tonometry was 0.22 mmHg (SD: 0.44 mmHg). The limits of agreement were calculated to be −0.64–+1.08 mmHg (1.96 SD either side of the bias). Conclusion: The Perkins applanation tonometer yields IOP measurements that are closely comparable with GAT. Therefore, PAT may be used in routine clinical practice, as part of the implementation of national guidelines,
    [Show full text]
  • Preliminary Results of an Intravitreal Dexamethasone Implant (Ozurdex®) in Patients with Persistent Diabetic Macular Edema
    Clinical Ophthalmology Dovepress open access to scientific and medical research Open Access Full Text Article MethodoloGY Preliminary results of an intravitreal dexamethasone implant (Ozurdex®) in patients with persistent diabetic macular edema Elena Pacella1 Background: To evaluate the efficacy and safety of an intravitreal dexamethasone implant Anna Rita Vestri2 (Ozurdex®; Allergan Inc, Irvine, CA, USA) in patients with persistent diabetic macular edema Roberto Muscella1 (DME) over a 6-month follow-up period. Maria Rosaria Carbotti1 Methods: Seventeen patients (20 eyes) affected by DME were selected. The mean age was Massimo Castellucci1 67 ± 8 years, and the mean duration of DME was 46.3 ± 18.6 months. The eligibility criteria Luigi Coi1 were: age $18, a best-corrected visual acuity between 5 and 40 letters, and macular edema with a thickness of $275 m. Thirteen patients had also previously been treated with anti-vascular Paolo Turchetti3 µ endothelial growth factor medication. Fernanda Pacella1 Results: The mean ETDRS (Early Treatment Diabetic Retinopathy Study) value went from 1 For personal use only. Department of Sense Organs, 18.80 ± 11.06 (T0) to 26.15 ± 11.03 (P = 0.04), 28.15 ± 10.29 (P = 0.0087), 25.95 ± 10.74 Faculty of Medicine and Dentistry, Sapienza University of Rome, Rome, (P = 0.045), 21.25 ± 11.46 (P = 0.5) in month 1, 3, 4, and 6, respectively. The mean logMAR Italy; 2Department of Public Health (logarithm of the minimum angle of resolution) value went from 0.67 ± 0.23 (at T0) to and Infectious Diseases, Faculty of 0.525 ± 0.190 (P = 0.03), 0.53 ± 0.20 (P = 0.034), and 0.56 ± 0.22 (P = 0.12) in month 1, 3, Pharmacy and Medicine, Sapienza University of Rome, Rome, Italy; and 4, respectively, to finally reach 0.67 ± 0.23 in month 6.
    [Show full text]
  • Congenital Corneal Clouding: a Case Series
    Case Series Congenital corneal clouding: A case series Sushma Malik1, Vinaya Manohar Lichade2, Shruti M Sajjan3, Prachi Shailesh Gandhi2, Darshana Babubhai Rathod4, Poonam Abhay Wade5 From 1Professor and Head, 2Assistant Professor, 3Resident, 4Associate Professor, Department of Pediatrics, 5Associate Professor, Department of Opthalmology, Topiwala National Medical College, B.Y.L.Ch. Nair Hospital, Mumbai, Maharashtra, India Correspondence to: Dr. Vinaya Manohar Lichade, Flat A14, Aanand Bhavan, Third Floor, Nair Hospital, Mumbai - 400 008, Maharashtra, India. E-mail: [email protected] Received - 18 February 2019 Initial Review - 11 March 2019 Accepted - 16 March 2019 ABSTRACT Congenital corneal clouding often causes diagnostic dilemma; hence, detailed evaluation and timely intervention are required to decrease the morbidity. Various genetic, developmental, metabolic, and idiopathic causes of congenital corneal clouding include Peters anomaly, sclerocornea, birth trauma, congenital glaucoma, mucopolysaccharidosis, and dermoids. We report a case series of four neonates with congenital corneal clouding admitted in our neonatal intensive care unit, over 5 years. Two cases were of Peters anomaly, one each of primary congenital glaucoma and glaucoma secondary to congenital rubella. Key words: Buphthalmos, Corneal clouding, Glaucoma, Peters anomaly he prevalence of congenital corneal opacities (CCO) is 5 years (Table 1). Two cases were of Peters anomaly, the third estimated to be 3 in 100,000 newborns. This number neonate was of primary congenital glaucoma, and the fourth Tincreases to 6 in 100,000, if congenital glaucoma patients are had glaucoma secondary to congenital rubella. The two cases included. Corneal opacifications of infancy are caused by several of Peters anomaly were siblings and the first case was a full- different disorders such as anterior segment dysgenesis disorders term female child with Peters Type 2 (Figs.
    [Show full text]
  • Confidential: for Review Only
    BMJ Confidential: For Review Only Defining a new threshold for ocular hypertension and estimating referral burden from the EPIC-Norfolk Eye Study: a cross-sectional study of the potential impact on referrals to the Hospital Eye Services Journal: BMJ Manuscript ID BMJ.2016.036789 Article Type: Research BMJ Journal: BMJ Date Submitted by the Author: 21-Dec-2016 Complete List of Authors: Chan, Michelle; UCL Institute of Ophthalmology , Division of Genetics & Epidemiology Broadway, David; Norfolk and Norwich University Hospital, Department of Ophthalmology Khawaja, Anthony; University of Cambridge, Department of Public Health & Primary Care Garway-Heath, David; NIHR Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology , Optometry Burr, Jennifer; Universityof St Andrews, School of Medicine Luben, Robert; University of Cambridge, Department of Public Health and Primary Care Hayat, Shabina; University of Cambridge, Department of Public Health & Primary Care Dalzell, Nichola; University of Cambridge, Department of Public Health & Primary Care Khaw, Kay-Tee; University of Cambridge, Clinical Medicine Foster, Paul; Moorfields Eye Hopsital NHS Foundation Trust, Intraocular pressure, Glaucoma, Ocular tonometry, Ocular hypertension, Keywords: England https://mc.manuscriptcentral.com/bmj Page 1 of 24 BMJ 1 2 3 Defining a new threshold for ocular hypertension and estimating referral burden from 4 the EPIC-Norfolk Eye Study: a cross-sectional study of the potential impact on 5 6 referrals to the Hospital Eye Services 7 8 Confidential: For Review Only 9 Michelle P Y Chan, David C Broadway, Anthony P Khawaja, David F Garway-Heath, 10 11 Jennifer M Burr, Robert Luben, Shabina Hayat, Nichola Dalzell, Kay-Tee Khaw, Paul J 12 Foster 13 14 15 Division of Genetics and Epidemiology, UCL Institute of Ophthalmology, 11-43 Bath Street, 16 London EC1V 9EL, UK.
    [Show full text]
  • Acute Rabbit Eye Model for Testing Subretinal Prostheses
    https://doi.org/10.1167/tvst.8.5.20 Article Acute Rabbit Eye Model for Testing Subretinal Prostheses Ying Xiao1,*, Yuqin Wang1,*, Fangting Li1, Tiezhu Lin1, Kristyn Huffman1, Stephanie Landeros1, Brandon Bosse2, Yi Jing2, Dirk-Uwe Bartsch1, Scott Thorogood2, William R. Freeman1, and Lingyun Cheng1 1 Department of Ophthalmology, Jacobs Retina Center at Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA 2 Nanovision Biosciences, Inc., La Jolla, CA, USA Correspondence: Lingyun Cheng, Purpose: Subretinal prostheses are a novel technology for restoring useful vision in MD, Jacobs Retina Center/Shiley Eye patients with retinitis pigmentosa or age-related macular degeneration. We Institute at University of California, characterize the surgical implantation technique and functional time window of an San Diego, La Jolla, CA 92037, USA. acute rabbit eye model for testing of human subretinal prostheses. e-mail: [email protected] Dr. Xiao is a faculty member at Methods: Retinal prostheses were implanted subretinally in 26 rabbits using a two- Provincial Hospital affiliated to step technique. Fundus imaging, fluorescein fundus angiography, and optical Shandong University, No. 324, Jing- coherence topography (OCT) were conducted postoperatively from days 1 to 21 to wu Weiqi Rd, Jinan City, Shandong monitor prosthesis positioning and retinal anatomic changes. Province, China 250021. Results: Successful implantation and excellent retina apposition were achieved in Dr. Wang is a faculty member at Eye 84.6% of the rabbits. OCTs showed the overlying retina at full thickness for the first 2 Hospital and School of Ophthalmol- days after implantation. Histology confirmed intact inner layers of the overlying retina ogy and Optometry, Wenzhou until day 3.
    [Show full text]