6U CompactPCI Platforms cPCIS-3300BLScPCIS-3300BLS Series Series Blade Chassis for 12 PICMG 2.16 Blades with Dual Fabric Switch Slots

Specifications

Mechanical Specifications Refer to the 3300 series base chassis specifications on page 4-4 cBP-6614A: 14-slot PICMG 2.16 6U cPCI Blade Server Backplane CompactPCI standards PICMG 2.0 R3.0, PICMG 2.1 R2.0 PICMG 2.9 R1.0, PICMG 2.11 R1.0 PICMG 2.16 R1.0 2.16 Node slot 12 2.16 Fabric slot 2 cPCI Bus None System slot All node slots act as system slot cPCIS-3300BLS Front View CMM slot 1 Rear I/O P3, P4, P5 rear I/O with AB-type shroud H.110 bus None cPCIS-3300BLS Rear View V (I/O) 3.3V or 5V (default) selectable Power socket 3 for 6U 8HP redundant power supply Power input AC or DC input, one ATX connector, DC screw terminals CMM: Chassis Monitors boards via the Intelligent Platform Management Interface Management Module (IPMI) (Model dependent) Monitors backplane voltage and status for up to eight power supplies Features System event logging for abnormal statuses Standard 6U CompactPCI and PICMG 2.16 open architecture Remote login and management via LAN or modem Dual PICMG 2.16 fabric slots for high availability Remote reset control for computing blades 21 slots, including 12 configurable node slots, 2 fabric slots, 3 redundant 6U 8HP Web-based GUI for both remote and stand-alone applications CompactPCI power modules, and 1 optional CMM slot Hot swappable 800W+400W redundant power supplies with Universal AC input Power Supply Supports up to 3 in-rack 6U cPCI 8HP power modules PICMG 2.9 compliant backplane with FAL#, DEG# sense, and INH# control for each Supports current sharing on 5V, 3.3V, and 12V power module PICMG 2.11 47-pin power interface Optional CMM for remote monitoring and controlling via Available power module: cPS-H640/AC (400W redundant) Guarded power switch and reset button Weight 23kg/50.7lbs (including redundant power supply and backplane) Redundant cooling architecture Magnetic circuit breaker protection for AC-input Operating Temp. 0 to 55˚C (depending on system configurations) Storage Temp. -20 to 80˚C Humidity 5% to 95%, non-condensed Ordering Information Shock 15G peak-to-peak, 11ms duration, non-operation Vibration Non-operation: 1.88Grms, 5-500Hz, each axis cPCIS-3300BLS Blade Server Chassis for 12 CompacPCI Blades and Dual Fabrics, Operation: 0.5Grms, 5-500Hz, each axis, test with 2.5" HDD without PSU cPCIS-3300BLS/AC Blade Server Chassis for 12 CompacPCI Blades and Dual Fabrics, with 3 cPS-H640/AC PSU cPCIS-3300BLS/M/AC 9U Rackmount CompactPCI Blade Server Sub-system with CMM and 3 cPCIS-3300BLS System Architecture cPS-H640/AC PSU

Note: EMC blank panels (cPCI-Panel-Kit-6U1S) are optional. All models above do not include any system or On/ OFF Switch & LED Indicators peripheral board. 2+1 Redundant 6U Power Supply Optional Chassis Monitoring Module

+5V +3.3V

Power +12V -12V

RES FAN TEMP

Fan Tray 1 Fan Tray 2 Fan Tray 3 Fan Tray 4 Fan Tray 5 F F

abric Board abric Board abric CompactPCI CompactPCI CompactPCI

POWER POWER POWER Node Board Node Board Node Board FAULT FAULT FAULT Redundant Fan cPS- cPS- cPS- H640/ H640/ H640/ AC AC AC Tray Design INPUT RANGE INPUT RANGE INPUT RANGE 100-240 VAC 100-240 VAC 100-240 VAC 60/50 Hz 60/50 Hz 60/50 Hz 400W HOT SWAP 400W HOT SWAP 400W HOT SWAP PICMG 2.11 PICMG 2.11 PICMG 2.11 CMM

Fan Tray 6 Fan Tray 7 Fan Tray 8 Fan Tray 9 Fan Tray 10

2 Redundant Ethernet Fabric Slots 12 PICMG 2.16 Node Slots

All specifications are subject to change without further notice. 4-5