Final Report

Total Page:16

File Type:pdf, Size:1020Kb

Final Report Final Report Reducing Taste and Odor and Other Algae-Related Problems for Surface Water Supplies in Arid Environments Prepared by Milton Sommerfeld Department of Plant Biology Arizona State University, Tempe, AZ Paul Westerhoff Department of Civil and Environmental Engineering Arizona Stae University, Tempe, AZ Larry Baker Baker Consulting St. Paul, MN Contributors: Qiang Hu, Mario Esparza-Soto, Darlene Bruce, My-Linh Nguyen, Thomas Dempster, Kirsten Hintze, Samanth Dawson, Mari Rodriguez, Michelle Cummings, Marisa Masles, and Dave Lowry Arizona State University, Tempe, AZ August 2002 ACKNOWLEDGEMENTS This project was financially supported by the City of Phoenix, AZ. Field, laboratory and analytical activities were performed by a series of talented post-doctoral researchers (Mario Esparza-Soto, Qiang Hu, Darlene Bruce), analytical technicians (Marisa Marsles, David Lowry), Ph.D. graduate students (Tom Dempster, My-Linh Nguyen, Kirsten Hintze), Master graduate students (Samanth Dawson, Mari Rodriguez-Hernandez, Michelle Cummings), and undergraduate students. ii ACRONYMS ADEQ - Arizona Department of Environmental Quality CAP - Central Arizona Project CAWCD - Central Arizona Water Conservatin District Cfs - Cubic feet per second COP - City of Phoenix DOC- dissolved organic carbon DBP - disinfection byproduct FPA - GAC - granulated activated carbon GC/MS - gas chromatography/mass spectroscopy HAA- haloacetic acids HPA - MCL - Maximum Contaminant Limit MWD - Metropolitan Water District of Southern California MIB - 2- methylisoborneol MPI - Malcolm Pirnie Inc. NAWQA - National Water Quality Assessment program (USGS) PAC- powdered activated carbon SPME - Solid Phase Micro-Extraction SRP - Salt River Project T&O - taste and odor T&OCS - Taste and Odor control Study THM - trihalomethane USEPA - U.S. Environmental Protection Agency USGS - United States Geological Survey UV - ultraviolet WTP - Water Treatment Plant iii TABLE OF CONTENTS SECTION PAGE EXECUTIVE SUMMARY ................................................................................................................ 1 SECTION 1: PROJECT OBJECTIVES........................................................................................ 13 SECTION 2: MONITORING PROGRAM (TASK 1)..................................................................... 16 SECTION 3: FIELD SCALE EXPERIMENTS TO EVALUATE T&O CONTROL MEASURES (TASK 2) ................................................................................................................. 73 SECTION 4: ASSESSMENT OF IN-PLANT CONTROLS (TASK 3) .......................................... 95 SECTION 5: CONTROLLED LABORATORY EXPERIMENTS (TASK 4) ................................ 115 SECTION 6: STUDIES OF DOC SOURCE, CHARACTERIZATION, AND TREATABILITY (TASK 5) ............................................................................................................... 187 SECTION 7: MIDCOURSE EVALUATION (TASK 6) ................................................................ 209 SECTION 8: IMPLEMENTATION CONTROLS (TASK 7)......................................................... 257 SECTION 9: SUMMARY AND RECOMMENDATIONS ............................................................ 282 APPENDIX A: BASELINE DATA TABLES................................................................................. 295 iv EXECUTIVE SUMMARY The goal of this project was to develop a comprehensive management strategy to reduce algae- related water quality problems for drinking water supplies in arid environments. Algae can cause problems in water supply lakes, water distribution canals, and water treatment plants. The primary focus was the taste and odor problem. However, because algae also produce dissolved organic carbon (DOC), which reacts to form disinfection by-products (DBPs) and contribute other in-plant operational problems, these issues will also be addressed. This final report includes a summary of findings related to research and field-scale activities aimed at algae-related problems. Specific sections include: · Summary of research report (Tasks 1 through 5) · Implementation report and Overview of Guidance Manual (Tasks 6 through 8) · Summary of Research Products · Future Research Needs · Recommendations for T&O Control and regional T&O management RESEARCH REPORT (TASKS 1 THROUGH 5) The research aspect of this project included five tasks. The major findings of each task will be summarized. The five tasks included: · Task 1 – Monitoring program · Task 2 – Field scale experiments to evaluate T&O control measures · Task 3 – Assessment of in-plant controls · Task 4 – Controlled laboratory experiments · Task 5 – Studies of DOC source, characterization, and treatability Task 1 – Monitoring Program The initially selected set of 20 baseline monitoring sites proved to be well-selected, with only a few additional sites added to the monthly monitoring program in order to obtain a comprehensive evaluation of the raw water system for the City of Phoenix. The hydraulic operation of this system is complex and dynamic. During the period of study, precipitation and watershed runoff was below average, and therefore represented a “drought” condition. Results differing from those encountered and reported here may occur during wetter years in the watershed. The work conducted during this task has lead to an improved understanding of the factors leading to T&O production in arid region surface water systems. MIB and Geosmin concentrations exhibited seasonal patterns (highest in summer and fall) and 1 significant spatial variability. MIB data are shown in Figure E.1 as contour plots with respect to concentration (ng/L). MIB was the dominant T&O compound observed in the watershed and finished drinking water systems. Geosmin occurred at lower concentrations. MIB and Geosmin spatial and temporal trends followed predictable patterns with regards to water temperature and nutrient conditions. The highest MIB concentrations (>50 ng/L) were found in the reservoir epilimnion and downstream points of the canal systems. The algae species responsible for T&O compound production ("culprit" algae) represented only a very small percentage of the total algae numbers or biomass. Intensive monitoring indicated “hot spots” for MIB production. For example, plankton in the open water of Saguaro Lake appeared to be the source of MIB, rather than pockets of benthic algae in shallower portions of the lake. In contrast, periphytic algae attached to the concrete- lined canal walls at two locations was a major source of caused MIB production in Arizona Canal. Task 2 – Field Scale Experiments to Evaluate T&O Control Measures Due to access limitations to reservoirs and non-site specific T&O spatial occurrence in the reservoirs, field-scale experiments were focused on MIB and Geosmin production in the canals. Experiments focused on (1) mechanical canal brushing of canal walls, (2) chemical liquid copper application to the canals, and (3) polymeric biocides fixed to canal walls. Mechanical brushing removed over 80% of the periphyton biomass from the canal walls and essentially lead to zero net MIB production along the length of the treated canal section. Copper addition lead to a gradual decrease in biomass, but a more rapid decrease of in-canal MIB production. In the weeks after both mechanical brushing and copper treatment biomass regrowth occurred, followed by MIB production. The treatments appear effective for two to three weeks. A combination of first mechanical brushing followed one week later by copper treatment would be a recommended course of action for MIB control in reaches of canals identified to produce T&O compounds. Task 3 – Assessment of In-plant Controls An assessment of each City of Phoenix WTP was conducted. No in-plant production of MIB or Geosmin was documented at any of the City of Phoenix WTPs which all practice periodic prechlorination, although reports of such production have been noted at City of Tempe and Chandler which do not prechlorinate. Conventional WTPs offer limited potential to control MIB and Geosmin present in the raw/influent water. The COP therefore has four options to minimize MIB and Geosmin in the finished water: 1. Minimize raw water T&O levels through upstream controls (e.g., canal treatments) 2. Optimize PAC brand selection, feed rates, and feed capability 3. Allow filters to operate in a biological mode 4. Upgrade treatment processes to include advanced oxidation processes or nanofiltration/reverse osmosis membranes. 2 Task 4 – Controlled Laboratory Experiments Experiments were conducted in the laboratory to (1) screen parameters important for implementation at field- or full-scale and (2) gain insights into a biological process or mechanism. Powder activated carbon (PAC) tests demonstrated PACs ability to remove MIB and Geosmin from surface waters in Arizona. Performance of PAC brands varied and was lower in surface water than distilled water. Kinetics tests for MIB adsorption requires at least one hour of contact time. Ozone and advanced oxidation processes that produce hydroxyl radicals can oxidize MIB and Geosmin, and are more effective than chlorine dioxide; chlorine did not oxidize MIB or Geosmin. Two biocide coatings fo the canal walls were evaluated. Copper biocides can kill MIB-producing algae, but organically-complexed copper products should be avoided since they react with free chlorine to form organic chloramines. Inorganically complexed copper products are recommended. Coating concrete canal walls with biocides or photo-reactive paints
Recommended publications
  • Protocol for Equipment Verification Testing For
    CHAPTER 3 EPA/NSF ETV EQUIPMENT VERIFICATION TESTING PLAN COAGULATION AND FILTRATION FOR THE REMOVAL OF MICROBIOLOGICAL AND PARTICULATE CONTAMINANTS Prepared By: NSF International 789 Dixboro Road Ann Arbor, Michigan 48105 Copyright 2002 NSF International 40CFR35.6450. Permission is hereby granted to reproduce all or part of this work, subject to the limitation that users may not sell all or any part of the work and may not create any derivative work therefrom. Contact ETV Drinking Water Systems Center Manager at (800) NSF-MARK with any questions regarding authorized or unauthorized uses of this work. April 2002 Page 3-1 TABLE OF CONTENTS Page 1.0 APPLICATION OF THIS VERIFICATION TESTING PLAN .....................................3-6 2.0 INTRODUCTION ................................................................................................................3-6 3.0 GENERAL APPROACH.....................................................................................................3-7 4.0 OVERVIEW OF TASKS.....................................................................................................3-7 4.1 Task A: Characterization of Feed Water ................................................................................3-7 4.2 Task B: Initial Test Runs........................................................................................................3-7 4.3 Task 1: Verification Testing Runs..........................................................................................3-7 4.4 Task 2: Feed Water and Finished Water
    [Show full text]
  • How Is the Thermal Performance of Solar Heating Systems Influenced by Thermal Stratification in the Heat Storage
    Literature study How is the thermal performance of solar heating systems influenced by thermal stratification in the heat storage Prepared as part of SolNet PhD course No. 13 “Heat Storage for Solar Heating Systems” held during 17-23 May 2014 at Danish Technical University, Lyngby, Copenhagen, Denmark Adrian Pugsley (University of Ulster, Jordanstown, UK) Stefano Poppi (Dalarna University, Borlänge, Sweden) 22 May 2014 1 Contents Literature study ............................................................................................. 1 How is the thermal performance of solar heating systems influenced by thermal stratification in the heat storage ....................................................................... 1 1 Introduction ............................................................................................. 3 1.1 Aim ................................................................................................... 3 1.2 Objectives .......................................................................................... 3 1.3 Solar water heating systems overview ................................................... 3 1.3.1 Tank and heat exchanger arrangements .............................................. 3 1.3.2 Passive and active systems ............................................................. 4 1.4 Definition of thermal stratification ......................................................... 5 1.5 Sanitary considerations ........................................................................ 5 2 The importance
    [Show full text]
  • Comparing Modes of Operation for Residential Ceiling Fans to Achieve Thermal Destratification 12/15/2014
    WHITE PAPER COMPARING MODES OF OPERATION FOR RESIDENTIAL CEILING FANS TO ACHIEVE THERMAL DESTRATIFICATION 12/15/2014 Credit: Thomas Lesser, Research Engineer Jay Fizer, Research-and-Development Laboratory Manager Christian Taber, Applications Engineer Overview Conventional wisdom says to reverse the direction of a ceiling fan’s rotation in the winter. Heat rises, filling a room with warm air from the top down and requiring heaters to run longer to achieve a desired ambient air temperature at the height of the thermostat and occupants. Running a fan in reverse helps move this heat across the ceiling and down the walls, recirculating the warm air through the space. Fans have been capable of reversing direction for decades, and legislation was passed in 2007 that required ceiling fans to have a reverse function. The logic behind reversing a fan is simple: since running fans in the forward direction creates a cooling effect through air movement, reversing those fans helps recirculate heat in the winter without creating an uncomfortable cooling draft. Big Ass Fans is aiming to prove that there’s a more energy-efficient and comfortable way to address heating conservation with ceiling fans. This study compared the effects of paddle fan reversal with Big Ass Fans’ Haiku ceiling fan, operating in the forward direction at lower speed settings than a paddle fan. Hypothesis Primary Hypothesis: Reverse Operation Is Less Efficient Reversing a paddle fan is not the best way to efficiently recirculate heat and fight heat stratification. A Haiku ceiling fan, operating in the forward direction, can destratify a room more efficiently than paddle ceiling fans operating in reverse.
    [Show full text]
  • Market Characterization of Indoor Cannabis Cultivation
    Emerging Technologies Market Characterization of Indoor Cannabis Cultivation ET20SCE8030 Prepared by: Emerging Products Customer Service Southern California Edison April 2021 Indoor Cannabis Market Characterization ET20SCE8030 Acknowledgements Southern California Edison’s Emerging Products (EP) group is responsible for this project. It was developed as part of Southern California Edison’s Emerging Technologies Program under internal project number ET20SCE8030. Energy Resource Integration, LLC (ERI) conducted this study with the overall guidance and management from Dave Rivers and Edwin Hornquist. For more information on this project, contact [email protected]. Disclaimer This report was prepared by Southern California Edison (SCE) and funded by California utility customers under the auspices of the California Public Utilities Commission. Reproduction or distribution of the whole or any part of the contents of this document without the express written permission of SCE is prohibited. This work was performed with reasonable care and in accordance with professional standards. However, neither SCE nor any entity performing the work pursuant to SCE’s authority make any warranty or representation, expressed or implied, with regard to this report, the merchantability or fitness for a particular purpose of the results of the work, or any analyses, or conclusions contained in this report. The results reflected in the work are generally representative of operating conditions; however, the results in any other situation may vary depending upon
    [Show full text]
  • Comparison of Computational Results with a Low-G Nitrogen Slosh And
    Comparison of Computational Results with a Low-g, Nitrogen Slosh and Boiling Experiment Mark. E. M. Stewart1 VPL at NASA Glenn Research Center, Cleveland, Ohio, 44135 Jeffrey P. Moder2 NASA Glenn Research Center, Cleveland, Ohio, 44135 This paper compares a fluid/thermal simulation, in Fluent, with a low-g, nitrogen slosh and boiling experiment. In 2010, the French Space Agency, CNES, performed cryogenic nitrogen experiments in a low-g aircraft campaign. From one parabolic flight, a low-g interval was simulated that focuses on low-g motion of nitrogen liquid and vapor with significant condensation, evaporation, and boiling. The computational results are compared with high-speed video, pressure data, heat transfer, and temperature data from sensors on the axis of the cylindrically shaped tank. These experimental and computational results compare favorably. The initial temperature stratification is in good agreement, and the two-phase fluid motion is qualitatively captured. Temperature data is matched except that the temperature sensors are unable to capture fast temperature transients when the sensors move from wet to dry (liquid to vapor) operation. Pressure evolution is approximately captured, but condensation and evaporation rate modeling and prediction need further theoretical analysis. Nomenclature 2 a, acg = acceleration, acceleration of center of gravity, m/s ALAT = Air Liquide Advanced Technology CNES = Centre National d’Etudes Spatiales Cp, Cv = specific heat at constant pressure and constant volume, J/kg-K c = VOF fraction, unitless
    [Show full text]
  • Destratair Brochure
    The most effective destratification & air distribution system Minimising energy use and reducing heating and cooling costs DESTRATAIR TECHNICAL INFORMATION DESTRATAIR TECHNICAL INFORMATION BENEFITS What is DestratificationBENEFITS ? Why Destratair ? Minimising energy usage by redistribution of • Exceptional Performance in a • Flexible Control high level warm air. compact design All units are speed controllable making Minimising energy usage by redistributionAir Distributionof • Exceptional - The Destratair Performance product in ais unique in that• Flexible it Control Thermal destratification is the process of mixingDestratification to within 1ºC. commissioning of the system quick and Destratair utilizes the total heat available becomes the prime air mover not only pushing hot air back the internal air in a buildinghigh to leveleliminate warm air.stratified compact design efficient. All units are speed controllable making layershowever and genera achieveted, and redistributestemperature it equalization down into the Destratificationoccupied zone, to withinbut distributing 1ºC. the heatedcommissioning or of the system quick and Destratair utilizes the total• Energyheat available Efficient throughoutcounteracting the the naturalspace. tendencyAir stratification of the occurs cooled air evenly around the space. efficient. however generated, and redistributesMinimising it energy usage by redistribution • Easy Maintenance inhot allair tobuildings rise to the andunderside can ofresult the roof. in dramatic • Energy Efficient counteracting the natural tendencyof high level ofDestratair the warm air. fansUp to are 20% wall saving mounted in at Lowabout level 3m mounting from the of floorunits means easy temperature differences from floor to ceiling and and throw air upMinimising across the energy roof usage creating by redistribution an air movement• back Easy Maintenance System design utilising Destratairhot air as to the rise to the undersidefabric of relatedthe roof.
    [Show full text]
  • Cfd Simulation of Stratified Thermal Energy Storage Tank Ecovat
    Ecovat® Seasonal Thermal Energy Storage CFD SIMULATION OF STRATIFIED THERMAL ENERGY STORAGE TANK ECOVAT PREPARED BY: HAMED KHATAM BOLOURI SANGJOEEI SUPERVISION BY: ECOVAT TEAM Winter 2021 Abstract Ecovat as a stratified thermal storage tank brings the possibility of making optimal use of renewable energy demands flexibility for heating and cooling. Regarding utilization of Thermal stratification in the storage tank, some unbalancing for thermal stratification would emerge during charging and discharging. In this project, a Computational Fluid Dynamics investigation on Ecovat is performed to determine the effects of inlet hot water, thermocline thickness, temperature difference between inlet water and existing water in tank, and position of diffusers on the mixing and thermocline formation, which influenced the performance of Ecovat systems and thermal stratification. Furthermore, the CFD model would be Proposed for the the whole Ecovat system (Diffusers and Tank) for the first time and this model can be utilized to simulate the Ecovat with custom dimensions based on the client’s requirements. CFD Simulation will demonstrate how the Ecovat system will work in real operational cases. ii | P a g e Table of Contents Abstract ............................................................................................................................... ii Table of Contents ............................................................................................................... iii List of Figures ....................................................................................................................
    [Show full text]
  • Solar Combi Systems Department of Civil Engineering
    Elsa Andersen Department of Civil Engineering Solar Combi Systems Department of Civil Engineering Civil of Department Systems Combi Solar Elsa Andersen Solar Combi Systems Department of Civil Engineering Report no R-156 2007 ISSN 1601-2917 ISBN 978-87-7877-228-2 P H D T H E S I S BYG • DTU Solar Combi Systems Elsa Andersen Ph.D. Thesis Department of Civil Engineering Technical University of Denmark 2007 Solar Combi System Copyright (c), Elsa Andersen, 2007 Printed by DTU-Tryk Department of Civil Engineering ISBN number: 9788778772282 ISSN number: 1601-2917 Preface This thesis is submitted as a fulfilment of the requirement for the Danish Ph.D. degree. The thesis is divided into two parts. The first part introduces the motivation and highlights the major findings and conclusions. The second part is a collection of papers, presenting the research in details. Ten papers are written, all of them with more than one author. Below is listed the division of labour in preparing the papers: Paper I. Thermal performance of Danish solar combi systems in practice and in theory, Journal of Solar Energy Engineering, Vol. 126, pp. 744 – 749, May 2004. Elsa Andersen has written the paper. Louise Jivan Shah has carried out the parameter analysis for solar combi systems shown in Figures 8 and 9 and proof-read the paper. Simon Furbo has supervised the Ph.D. study and proof-read the paper. Paper II. The influence of weather on the thermal performance of solar heating systems, submitted to Journal of Solar Energy, May 2007. Elsa Andersen has written the paper.
    [Show full text]
  • Evaluation of a Stratified Multi-Tank Thermal Storage for Solar Heating Applications
    EVALUATION OF A STRATIFIED MULTI-TANK THERMAL STORAGE FOR SOLAR HEATING APPLICATIONS by Cynthia Ann Cruickshank A thesis submitted to the Department of Mechanical and Materials Engineering In conformity with the requirements for the degree of Doctor of Philosophy Queen’s University Kingston, Ontario, Canada June, 2009 Copyright © Cynthia Ann Cruickshank, 2009 Abstract A novel multi-tank thermal energy storage (TES) was evaluated experimentally and numerically. The multi-tank storage is based on the interconnection of standard hot water storage tanks by a single charge flow loop. Each tank is charged through a thermosyphon loop and natural convection heat exchanger (NCHE). Both series- and parallel-connected configurations were investigated and results show that high degrees of stratification can occur. To predict the performance of the series- and parallel-connected multi-tank TES, a numerical model was developed and implemented in the TRNSYS simulation environment. Laboratory tests were also conducted to measure the unit’s performance under charge conditions representative of combinations of clear and overcast days. The effects of rising and falling charge loop temperatures and power levels on storage temperatures and heat transfer rates were studied and indicated that sequential stratification was achieved in the series-connected storage. Under certain conditions, reverse flow through the thermosyphon loops was identified, leading to destratification and carry-over of heat to the downstream storage tanks. Consequently, a new model was developed and showed to model reverse thermosyphon operation. A subsequent analysis showed that these effects could be minimized by careful system design. To quantify the relative benefits of the sequentially stratified TES, values of exergy stored versus time were determined and compared against fully stratified and fully mixed storages.
    [Show full text]
  • Zero Gravity Cryogenic Vent System Concepts for Upper
    ZERO GRAVITY CRYOGENIC VENT SYSTEM CONCEPTS FOR UPPER STAGES Robin H. Flachbart James B. Holt Leon J. Hastings Space Transportation Directorate NASA- Marshall Space Flight Center ABSTRACT The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space, and would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray-bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray-bar system consists of a recirculation pump, a parallel flow concentric tube heat exchanger, and a spray-bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure.
    [Show full text]
  • GLEON 19 Poster Session and New Sites Abstract Book
    Poster Session Abstract Book GLEON 19 Lake Mohonk, NY, USA 27 Nov - 1 Dec 2017 Co-hosted by SUNY New Paltz, Mohonk Preserve and Cary Institute of Ecosystem Studies, and with additional generous support from NYC Department of Environmental Protection Last updated 2017-12-13 Table of Contents Poster Abstracts ................................................................ 3 Last name: A-C ........................................................................... 3 Last name: D-F .......................................................................... 19 Last name: G-J .......................................................................... 32 Last name: K-L ......................................................................... 46 Last name: M-Q ......................................................................... 63 Last name: R-V ......................................................................... 80 Last name: W-Z....................................................................... 101 New Site Abstracts ....................................................... 108 2 Poster Abstracts 1. Lauren M. ADKINS1, Craig Williamson1, Abby McBee1, Tom Fisher2 Application of geographic information systems (GIS) techniques to identify potential public health risks from waterborne disease among lakes and reservoirs experiencing browning 1Department of Biology, Miami University, Oxford, Ohio, USA 2Department of Statistics, Miami University, Oxford, Ohio, USA Long-term data from two lakes in northeastern Pennsylvania revealed a correlation
    [Show full text]
  • Thermal Destratification of Air Streams to Improve the Cooling Provisioning of Air-Cooled Data Centers
    THERMAL DESTRATIFICATION OF AIR STREAMS TO IMPROVE THE COOLING PROVISIONING OF AIR-COOLED DATA CENTERS by ANTO JOSEPH BARIGALA CHARLES PAULRAJ THESIS Submitted in partial fulfillment of the requirements for the degree of Master of Science in Mechanical Engineering at The University of Texas at Arlington May 2019 Arlington, Texas Supervising Committee: Dr. Dereje Agonafer, Supervising Professor Dr. Abdolhossein Haji-sheikh Dr. Andrey Beyle Copyright by Anto Joseph Barigala Charles Paulraj 2019 ACKNOWLEDGEMENTS I would like to take this opportunity to express my sincerest appreciation to my supervising professor Dr. Dereje Agonafer for his exceptional support, guidance and inspiration throughout the course of my research work. The invaluable advice and timely support whenever required was the major driving force, which enabled me to complete my research work. I would like to thank Dr. Abdolhossein Haji Sheikh and Dr. Andrey Beyle for taking their time for serving as my committee members. I would also like to take this opportunity to thank Mr. Mark Seymour of Future Facilities for all his expertise and continuous support and feedback during the projects. His industrial expertise has been important for my research. Also, I would like to thank Ashwin Siddarth, Rajesh Kasukurthy and other lab mates for their invaluable support while working at the EMNSPC labs. I would like to thank all my friends in the EMNSPC team and my roommates who constantly supported me throughout my time here. Lastly, I would like to thank my parents Mr. Charles Paulraj Barigala Francis and Mrs. Jessia Margaret Selvaraj for their support both emotionally and financially, without which I would not have dreamt this far.
    [Show full text]