CYANO USER’S MANUALS Table of Contents

CAPTER 1 | INTRODUCTION 1

CAPTER 2 | CAUTIONS & WARNINGS 2

CAPTER 3 | GETTING STARTED 3

App Installation and Bluetooth connection

App description and use

Viewing settings

Logs and Settings

CAPTER 4 | DIVING 9

Preparing to dive

Alarms

Dive mode

CAPTER 5 | SERVICING 13

CAPTER 6 | TECHNICAL SPECIFICATIONS 15

Algorithm

Other specificiations

CAPTER 7 | COPYRIGHTS, BRAND, TRADEMARK, KC CERTIFIED 17

CAPTER 8 | DEFENITIONS 18

Appendix | ACCESSORIESS 19 Introduction

CYANO

Derived from the Greek word Kuan(e)os, meaning "DEEP BLUE", a thick and dark blue color used to describe the sea.

The Cyano-RF is a wrist type diving computer with a compact and smooth design to satisfy your stylish everyday lifestyle integrated with an intuitive UI to provide important information clearly during your dive.

Compared to the usual LCD panel, the CYANO-RF is a computer equipped with a 1.54" ISP LCD Panel to provide a wider and clearer view of the information even at depth, also containing features and a digital compass.

You could share you diving logs through SNS with CYANO's application, as well as personalize your settings. You can comfortably charge wirelessly to avoid accidents caused by changing the battery. You can try on different styles of straps with CYANO's quick release strap with ease.

Warnings & Cautions

The following manual contains important information on how to use the CYANO-RF It is required for the user to read and understand this manual to be aware of the use and features of the CYANO-RF

● Wrong input of information may result malfunctions and so it is required to read the manual thoroughly

● Before using the CYANO-RF, it is recommended th understand and know the limits of the this computer Misuse of the product may lead to defection of product, serious injuries or death

● The CYANO-RF is to be used only by certified divers. The CYANO-RF is not be used as a sole instrument to refer during diving The CYANO-RF model is made for Recreational Diving ONLY ● Dives such as Technical or Commercial Dives extend outside the range of recreational diving being more exposed to DCI Therefore it is prohibited to use the CYANO-RF when executing dives that extend outside the range of recreational diving

● DECO stop procedures will be strictly exercised immediately, ignoring may result to serious injuries or death. Disobeying DECO stop procedures will result to prohibiting the use of this computer for 48 hours

● It is recommended to practice safety stops within 3~6 meters when ascending

● Please strictly obey required ascent rate to minimize danger of Illness (DCI). Ascending too fast may result to DCI and may result to serious injuries or death

An alarm and warning screen will appear 2 minutes before your NDL or 2 minutes before the computer enters DECO mode. It is strictly ● required to exercise DECO stop procedures in the required depth after entering the DECO MODE due to ignoring the alarm and not ascending earlier

It is impossible to eliminate entirely the of DCI with any instruments when diving, even when all safety procedures are met with correct ● dive plans and correct use of diving tables. It is recommended for the user to stay fit and healthy for the computer is unable to calculate personal fitness of each user, it is also recommended that the user dives after consulting with a physician

1 Warnings and Cautions

● CYANO-RF’s maximum partial for is set to 1.4bar.

The CYANO-RF does not support , therefore it is prohibited to use the CYANO-RF when diving in altitudes. ● It is recommended that the user makes sure the CYANO-RF has atleast 50% or more battery life before executing 1 dive. ●

● All data of will be lost if the CYANO-RF switches off due to lack of battery. If so ever the CYANO-RF switches off during a dive it is recommended to the user not to dive atleast 48 hours prior to the last dive.

It is recommended to access the CYANO app before exercising your 100th dive, ● for the CYANO-RF saves up to 99 dives ONLY and will delete the previous data's when exercising your 100th dive.

● Diving again within 5 minutes after reaching the surface will be regarded continuing your previous dive and the overall diving time will regard your short surface interval as part of the dive. After 5 minutes from reaching the surface, the dive will be regarded finish and your will be saved.

● Important features such as Log Book Memories, peronal settings will be retained even after the watch is turned off or turned off due to no battery. But current time, daily alarms and few simple settings will be resetted.

Please be adviced, buttons will not work during the continuous dive phase. ● It is recommended to avoid flying when the NO-FLY icon is displayed ignoring this may result to serious injury or death. ● Decompression table will not be calculated when diving with the Gauge mode ● when diving with the Gauge mode all responsibilities will be laid upon the user.

Free diving is prohibited after diving for 12~18 hours. due to the danger of SWB (Shallow Water Black out) and DCI (). ● Nitrox Diving is to be exercised ONLY by divers with Nitrox Specialty Certifications certified by training organizations that are ● registered in the RSTC (Recreational Scuba Training Council). Exceeding EAN40 when Nitrox Diving exceeds the limits of recreational sports diving therefore it is prohibited to use this computer when ● diving with more than EAN40. Please be careful not to let the phone’s screen turn off when uploading your dives to the app. ● You may upload your divelogs by pressing divelog after connecting your application. Please be adviced that the CYANO-RF will switch off if not connected with the phone within 5 minutes after being switched ON. ●

For further questions and inquiries please email us to the address below. [email protected]

CYANO membership card must be kept and used ONLY by the first user when servicing the product and is prohibited from lending or giving to another user ● The following membership card will not be reprinted therefore please be cautious for losses. ●

2 Getting Starting

App installation and Bluetooth connection

The following product is sold after being reset, ! Please follow the instructions below to use the CYANO-RF product

Use Playstore for Android phones, and App Store for iOS phones

Please connect to CYANO app with bluetooth 4A0503010

Sign up and Log In Turn on your computer(press the UP button) Click on the Bluetooth icon (Verify ID by clicking link sent to Email Required) (if computer does not turn on, please charge battery) (a pop up will be shown when bluetooth is turned off)

Click the designated Serial number See if it is connected Edit your protocol settings (refer to your membership card or (Bluetooth icon turns blue when connected) by clicking on the settings computer screen for the serial number) Press on the Start button

3 Getting Starting

Protocol Settings

The following product is sold after being reset, ! Please follow the instructions below to use the CYANO-RF product

Use Playstore for Android phones, and App Store for iOS phones

Check if basic measurements are set Enter Protocol Settings Set your date, time and GPS settings Check your watch (Please reconnect bluetooth (Date/Time/GPS will set automatically when clicked on) if not automatically set)

Menu and Watch Face

Watch face design (Theme / Color)

Select measurements

Select measurements

Alarm settings

Connected Computer Ver. Changing connected Comp. Reset Personalize your watch theme and color Protocol Settings

Company Website Terms of Use Logging Out

4 Getting Starting

Log Book

The following product’s GPS feature uses the GPS feature of the user’s phone. To use the log book’s GPS feature, GPS settings should be set at the Protocol Settings after connecting through Bluetooth.

Use Playstore for Android phones, and App Store for iOS phones

Enter Dive Log Select the preffered Log Check your Dive data

Type in a more detailed dive log Get your dive buddy or instructor to sign Share your dive log

5 Getting Starting

Charging

Place the CYANO-RF on the center top of the QI-charging pad and see if the charging light of the QI-charging pad changes from red to blue. note: misplacement may interupt charging speed of the computer. Take note the battery is a consumable material therefore battery use time may decrease as time passes

The following device uses Li-Polymer battery. Lithium Polymer batteries are thinner and is lessdangerous to explosion compared to Lithium Ion batteries. Therefore it is safe, light, and strong against battery leaks which makes it a much stress-free battery

Compatibility : any QI standard wireless rechargable device Use Time : Dive Mode - 10 hours at most Input : DC: 5V / 1A Time Mode - 18 hours at most (w/ sleep mode) Charging distance : 4~6mm Charging Time : 1hour 40minutes Stand by Mode - 15 days or more (power off)

Please be aware when using

Over charging may lead to defection of battery, explosion, serious injuries or death. Please do not expose to fire, and do not leave under sunlight and near water unattended

The screen may display an unstable percentage of the battery life during charging It is to show the exact amount of battery at the current situation so please be adviced you may continue charging.

For Battery Problems please refer to Defection Check up Q&A page

8 Getting Starting

Buttons Checking Current Settings (Status)

Menu / Enter / Up Back Enter Current Settings (Status) Current Settings (status) / Down by pressing the button

PPO2 ( Oxygen) Battery life Change ONLY when Nitrox Diving Brightness Dive Log

Bluetooth Personal Condition

Alarm Surface Interval

Gauge Mode Measurement Setting

No-Fly Time No-Dive Time

No-Fly Time Surface Interval It is best not to travel high altitudes and board a plane while the Surface Interval starts counting as the user surfaces out of water and changes No-Fly Time is counting down. No-Fly time counts 6 hours atleast, from DIVE MODE to TIME MODE. and depending on the user’s dive(s), time may increase. No-Dive Mode If the user does not follow decompressions procedures, the user is No-Dive Mode is activated as the user surfaces after not following recreational prohibited from flying at least 48 hours to decrease danger of DCI. dive regulations, then the user is prohibited from diving for atleast 48 hours. When No-Dive Mode is activated, the screen will blink 3 times followed by a pop up screen. The pop up screen can be exited by pressing any buttons, and time mode will appear.

Dive Plan Mode

(EAN21=AIR)

Depth PPO2 Non-Deco Limit

6 Getting Starting

Log and Settings

나이트룩스설정 다이빙로그

기타설정 전원

Enter Menu by pressing the UP button Press Up to enter, Down to move Use the UP & Down button to set your PPO2

Use the to go through Logs Press or to view log in detail by time (Move Automatically) To view details press the Down Button long Press or again to stop

Black Screen Brightness (1~4) 3 (10s, 30s, 60s)

Bluetooth Alarm

Gauge Mode off (Algorithm NOT Compass supported)

Calibration Screen (2 seconds) Turn the computer clockwise on a flat plain

7 Diving

The User MUST read and understand all the instructions and warnings stated in this manual before using the CYANO-RF, ● misuse of the product may lead to serious injuries or death

CYANO-RF dive computer is a recreational diving computer and exceeding limits of recreational diving may lead to serious injuries or death ● Nitrox diving with Nitrox settings should ONLY be executed by divers who are certified by internationally recognized ● diving schools such as SSI, PADI and those part of the RSTC

CYANO-RF diving computer should ONLY be used by divers who are certified by an instructor belonging to an ● internationally recognized SCUBA school such as SSI, PADI, and those part of the RSTC

CYANO-RF diving computer should ONLY be used by one user, lending is strictly prohibited for it may lead to serious injuries or death ●

CYANO-RF diving computer is NOT capable of underwater gas exhange, please take note when using the Nitrox feature. ●

Before Diving

1. Is the following mode suited for my diving? (Air / Nitrox / Gauge) 2. Is the battery enough? 3. is the compass calibrated? 4. are the measurements correct? (Meter / Feet) - Check with App

5. Are settings personalized? (condition, EAN settings and etc.) 3. Compass 5. Personal Settings

Nitrox Diving

Nitrox Diving refers to diving with decreased partial pressure of Nitrogen reducing the danger of and decompression time. By decreasing Nitrogen, Oxygen is increased where in divers are exposed to , therefore divers with Nitrox specialties certified by Internationally acknowledged SCUBA schools such as SSI, PADI and those part of the RSTC (Recreational Scuba Training Council) should be the ONLY divers to use the Nitrox feature.

Checkin Battery Status

Batteries are effected by its surrounding and internal consumption. Low battery signal may be shown although battery is charged when unattended for a period of time, or exposed to low for some time. If unused or unattend for some time, please remember to check your battery status before use. .*Consumable parts such as batteries are discluded from the warranty service CYANO provides. [refer to Pg.11 concerning After Service Policy]

Personal Settings

Compass Calibration Remember to Calibrate your Compass before diving, compass measurements may defer from place to place. Enter settings -> Calibration to calibrate your compass, take note to calibrate only on flat planes rotating a few times to get measurements correct. After measurements are adjusted, screen will automatically return to menu.

Personal Setting You may adjust condition settings up to 3 levels depending on your expereance and condition. Depending on your settings, decompression computations may vary, where as setting to POOR decreases your non-decompression limit, set to NORMAL for average computation set to POOR for when diving conditions including the user are not so good set to GREAT for when diving conditions including the user are excellent

Using the Dive Mode

1. The CYANO-RF changes to DIVE MODE automatically when, submerged under water at a depth of 1.5 meter for more than 30 seconds. 2. The CYANO-RF changes to DIVE MODE automatically when, submerged under water at a depth of more than 8 meters It is highly recommended to check Oxygen partial pressure settings and battery status before Diving

!Free Diving CYANO-RF model does not provide Free diving features

! High Altitude CYANO-RF model does not support high altitude diving, it is prohibited to use the CYANO-RF when diving high altitudes It is recommended not to travel to high altitudes after diving for this may effect silent bubbles within the body of the user resulting to serious injuries, DCI (decompression illness), and death.

9 Diving

User Interface

Brightness PPO2 Battery

Current Depth Water Temp.

Bottom Time NDL Ascent & Descent Bar

Stop Watch Maximum Depth

Current Time

Alarms

An alarm that appears 2 min. before reaching NDL The Alarm will be visible and heard when the user exceeds safe ascent speed The Alarm will be visible and heard 2 min. before reaching NDL This Alarm is to prevent exceeding recreational limits.

Critical Depth Alarm The Alarm will be visible and heard to help user to maintain An alarm will be visible and heard after reaching the depth of 40m designated STOP depths during Safety Stop and DECO Stop which is the depth limit for recreational divers to reduce danger of DCI procedures.

It is impossible to eliminate entirely the risk of DCI with any instruments when diving, even when all safety procedures are met with correct dive plans and ● correct use of diving tables. It is recommended for the user to stay fit and healthy for the computer is unable to calculate personal fitness of each user, it is also recommended that the user dives after consulting with a physician

This page is to warn and notify the user that no instruments or dive plans may eliminate the danger of DCI entirely. ● It is recommended for the user to consult with the , dive master or the instructor thoroughly concerning the dive plan before diving

10 Diving

Different Dive Modes

Color differs from Dive mode to Dive mode depending on the current state of diving. Usual Safety Stop Deco-Mode Gauge Mode

Normal Dive Mode The Blue dive mode is the normal mode when diving There are two types of interface during this mode where the user may use the prefered one The first interface includes the minimum information that is needed while exectuing a dive and also for users with low eye grades with informations displayed bigger compared to the second

Display 1 Display 2

Safety Stop Mode Doing Safety Stops is a good habit for divers It is recommended to all divers to prevent decompression illness as much as possible by stopping at a designated depth for a time to release residual Nitrogen within the body The CYANO-RF computes for Safety Stops if the computer was used more than 10 minutes during diving.

Safety Stop procedures After executing most of your dive, the computer’s interface will change to Safety Stop mode when ascending to depths of 8m The CYANO-RF will start alarming to ascend to a Safety Stop depth starting 6.5m and will count down from 5.9m It is recommended for the user to execute a Safety Stop before exiting the water

Diving with DECO MODE A red screen will appear when user exceeds his or her NDL and enters DECO MODE A visual alarm will appear to alert the user to ascend or descend to a designated depth to do a DECO STOP It is required for the diver to move to the designated depth to do a DECO STOP before exiting the water If not followed, the user may be exposed to serious injuries, DCI or death. Incase air in the tank is not enough to compensate for a DECO STOP, proceed with a DECO STOP until air lasts before exiting water.

Diving with Gauge Mode Calculations for an average Scuba Dive may differ when diving right after diving with the Gauge Mode The Gauge Mode does not include features such as an algorithm or ascent rate indicator All dangers or problems caused by Scuba Diving with the Gauge Mode is relied on the user The Gauge Mode does not compute for decompression procedures therefore it is prohibited to use the Gauge Mode when Scuba Diving

Diving in Nitrox Mode

Cautions before diving Residual Nitrogen and decompression calculations differ depending on the input of partial pressure Oxygen. Never round up the decimal point of the actual PPO2 when inputting to computer. (ex. 31.8% oxygen should be inputted as 31% to ensure safety If inputted incorrectly, and rounded up, this may result to a decompression dive where in No-Decompression Limits will be miscalculated. like wise when oxygen is misinputted the wrong way it may result to oxygen toxicity therefore please be cautious when inputting information. Dive Plan Mode will adjust NDL depending on the PPO2 that was set by the user.

Basic Nitrox Settings CYANO_RF sets PPO2 to 21%. The user may set his or her PPO2 from 21%~99% depending on the dive.

Always remember to consult with your instructor before doing any adjustments.

11 Diving

Using the Dive Mode 다이빙시간 관리하기

Compass

Press the button twice from dive mode

Brightness

Press button at the same time

Configurations set underwater ※ returns to original state after diving.

Stop Watch

[ENTER] Button starts the stopwatch while pressing again stops it, if pressed long enough stop watch resets

Gauge Mode

! Safety Stops and Decompression Stops will not work When diving in Gauge Mode, since it does not compute decompression procedures. (Gauge Mode only portrays Dive Time, measurements, Depths)

Please take note to check off that Gauge Mode is off before SCUBA Diving.

12 Warranty

● CYANO Premium Warranty CYANO provides a a premium warranty for a limited time in celebration of its launch. It is required to register the purchased product within a month at CYANO’s official homepage. ● 1. An additional 1 year warranty will be extended to those who are registered within a month after purchase resulting to a 2 year warranty. ● 2. For a year prior to purchase, Cyano will provide a free exhange of the watch bodies for defected products to those registered within a month after purchase ONLY once ● Please take note that defected products due to misuse of the user will be discluded in this case, once exchanged with a new watch body only servicing will be provided according to purchased country service regulations.

CYANO warranty service ● Free service concerning the defected part of the watch will be provided for a year after purchase. ● Free service will be provided for 6 months if within the period, same defects occur after receiving initial service. ● For unavailable products, Service may be limited. ● Free service will NOT be provided for products bought abroad. (Free service will ONLY be provided by the service center within the country where the watch was purchased)

Please contact nearest CYANO service center for more details

Warranty will NOT be provided for ● defects and damages caused by exposure to extreme temperatures ● natural defects and damages due to time of use ● not using product properly (damages made by sharp objects, damages caused by dropping or forcefully damaging product and etc.) ● defects and damages that occur due to not following CYANO Guildlines(예: Quick Manual or E-manual) ● defects and damages caused by using the product for other purposes aside from stated purpose ● using unauthorized parts to replace computer parts or altering parts of the computer ● accessories or parts that are consumable and exchangable ● products that are altered or serviced by unauthorized service centers or others ● illegal use or deletion of serial number : In this case CYANO HQ has the right to decide ● defects and damages caused by exposure to misquitto repelants and chemical substance as such ● defects and damages caused by exposure to extreme heat within a closed space such as microwaves ● defects and damages in the pressure sensors caused by packing the watch within a closed space such as hard cases and travelling by plane

Leakage caused by changing of battery by the consumer, user or others aside from the official CYANO service centers. All settings will reset after exchanging the battery except for personal settings and dive logs.

13 Warranty

● Maintenance Please put effort on caring and putting aside the CYANO computer ● Never dismantle the watch. Defects and damges that follow will not be covered by warranty. ● If any problems occur when using an accessory, always exchange or receive service from a Official CYANO service center. ● It is required to send the watch to the nearest CYANO service center for a check every after 100 dives or 2 years. ● These check ups require special tools therefore always use the nearest official CYAno service center. ● Contact the nearest CYANO service center for questions on any problems that occur or might occur. ● Misuse of the watch may leave a scratch on the glass of the watch. ● Glass exchange will be charged, therefor please always use a glass protector or body cover at all times. ● CYANO-RF must be used with a body cover. ● Always wash with clean water after use. If any fog appears on the glass while washing or using refrain from using the watch and directly contact the nearest CYANO service center. ● Always keep in dry area when not in use. ● Never expose watch to extreme temperatures or any chemical substance, this may result to of watch due to o-ring problems ● Never use a pressurized water spray or air spray on the watch.

● Battery ● The user or any other party is prohibited from exchanging the watch’s batteries. ● Always use the nearest CYANO service center. ● A battery is a consumable part therefore shortage may occur after a period of time. ● The wireless charging pad is also sold separately. ● Deletion of important information or settings may occur during servicing therefore always transfer important informations to the application before receiving service. CYANO and CYANO service centers will NOT be hold liable concerning deleted informations during servicing. ● Always charge the watch and maintain 30% of battery power even when not in use. ● problems in charging may occur when watch is left with NO battery for a long period of time.

● Buttons ● Exchange of buttons is recommended when buttons are too hard to press or to loose compared to initial use. ● Button defections may result to water leakage therefore occationally receive check ups from a near by CYANO service center before using for diving.

● Waterproof testing Waterproof testing of the watch will ONLY be executed by an official CYANO service center. a slip or receipt will be provided after testing. CYANO or CYANO service centers will not be hold liable after initial check ups for product defects caused by leakage without this slip or receipt CYANO or CYANO service centers will not be hold liable for problems or defects that occur after initial check ups done by a third party service center or by the USER or others.

14 Technical Specifications

B ühlmann(ZH-L16C) Algorithm ● CYANO uses bühlmann ZH-L16C as its algorithm. The Bühlmann decompression algorithm computes by detecting the inert gases that enter and leave the human body as the changes. This algorithm helps the diver to plan and executes his or her dive by being able to calculate those gases.The algorithm was developed by Swiss physician Dr. Albert A. Bühlmann, who did research into at the Laboratory of Hyperbaric at the University Hospital in Zürich, Switzerland. The results of Bühlmann's research that began in 1959 were published in a 1983 German book whose English translation was entitled Decompression-Decompression Sickness. The book was regarded as the most complete public reference on decompression calculations and was used soon after in dive computer algorithms. The model assumes limited and multiple parallel tissue compartments and uses an inverse exponential model for in-gassing and out-gassing, both of which are assumed to occur in the dissolved phase (without bubble formation).

Decompression Dives ● Decompression Dives refer to diving with the need of decompression under water to minimized the danger of DCI by lowering the amount of residual Nitrogen within the body, which is a result of exceeding recreational limits. Recreational divers a prohibited from exceeding these limits without learning the dangers and procedures.

2 Minunte Pre-alarm CYANO-RF helps the user not to exceed these limits by setting off an alarm visually and by sound to warn the user 2 minutes before his or her NDL

cause of Decompression Sickness ● the following may be the cause of decompression sickness which may vary from person to person.

Diving in waters under 20 degrees Divers with disabilities and physical illness Fatigue State Dehydrated State Divers with history of expereancing Decompression Illness Stress Obesity Divers with Patent Foramen Ovale (PFO) Radical excercise before diving

15 Technical Specifications

Case size 35mm x 40mm 57mm Case thickness 14.9mm Total length 270mm 105g

40mm 14.9mm

Dsiplay 1.54“ 240px TFT LCD Panel Algorithm Bühlmann ZH-L16C Glass Material K1 Glass Mode Dive / Gauge / Time (Reflect and scratch proof coating) Gas Air/Nitrox (21%~99%) Body Material Stainless 316L Safety Stop Depth / Time Display Cover Material PC+GF30% Non-decompression Limit Time Display Strap Material Silicon DECO Time Depth / Time Display Strap replacement Quick Release Spring Bar Alarm during Up / Down alarm Strap compatibility any 24mm watch strap DECO & Safety Stops Battery Li-Polymer(350mAh) Stop Watch Integrated Charging type Qi standard wireless (charging pad included) Current Time Integrated Charge Time 2hours 40minute Compass Integrated Working Depth 100m at most Dive Plan Mode Integrated Recommended depth 40m Ascent/Descent Rate Alarm / Notice / Speed Bar Use Time Dive Mode - 10 hours at most (brightness4) Battery display Integrated Time Mode - 18 hours at most (sleep mode) EAN Setting display Integrated Stand by Mode - 15 days at most (power off) Depth Alarm Integrated Brightness 4 levels No-Fly Time display Integrated Language English Accessaries (separate) Color (Mint/Pink) Strap measurements fahrenheit/celcius , meter/feet Leather (Black/Light Brown) Alarm / Time Included D-Ring Connector (316L) Watch face Design 16 types = 4color x 4design (2digital+ 2analog) Pendant Connector (316L) Memory 99 dive logs Body Cover (Urethane) Data Transfer Bluetooth 4.1 Glass Protecter (9H) Application Android / iOS Log Book/Management, SNS Settings, Watch face Design

16 Copyright, trademark, patent notice KC certification, quality assurance

Copyright : The following manual is made by CYANO, all rights reserved by CYANO, it is prohibited to use, distribute, relay, open nor copy without CYANO’s agreement. Brand : brands CYANO, WATOOM are protected under the trademarks law Patent : The following product’s patent are protected by the patent office.

● Compliance Certification

KC : MSIP-RMM-WaC-CYANO-RF

FCC : 2AN2P-CYANO-RF

CE, ROHS, WEEE

The following product may expereance radio interference, personal safety will not be hold liable nor guaranteed.

● Battery Certifications

.CELL UN38.3 (Shipping Certifications) / Report No. TCT170818B012

.PACK UN38.3 (Shipping Certifications) / Report No. TCT170818B009

.CELL CB (International Standards Certifications) / Certificate No. JPTUV-083210

.PACK CB (International Standards Certifications) / Certificate No. JPTUV-083211

.KC Certificate_ Certificate of Battery Safety Confirmation / Certificate No. XH100078-17030A

● Device Certifications

. KC Certificate (Compliance registration of broadcasting communication equipments) / Registration N : MSIP-RMM-WaC-CYANO-RF

. CE-RED (EU RED) / Certificate Number. DTNC52-1A

. RoHS (Restriction of Hazardous Substances Directive) / Test Report No. ERPO-170824-01-197-34

. WEEE (Waste Electrical and Electronic Equipment Directive) / Test Report No. EWP-170824-01-197-34

. FCC PART-15 C(Federal Communication Commission) / FCC IDENTIFIER : 2AN2P-CYANO-RF

. FCC PART-15B (US FC C Electromagnetic Certification) / Reference Report No. DREFCC1710-0279

● Design Registration (Design Protection Act) / Registered : Article Number 30-0979433. Application Number : Article Number 30-2017-0019613

● Trademark Registration (Trademark Law) / Registered : Article Number 40-1275346. Application Number : Article Number 40-2017-0006276

17 Definitions

● NDL (No-Decompression Limit) : Refers to time limit at a certain depth to avoid decompression diving

● Altitude diving : where the surface is 300 metres (980 ft) or more above

● Ascent rate : Ascent speed of a diver.

● Decompression : Releasing residual Nitrogen within the body, to avoid DCI

● Decompression sickness : Also known as “bends”is a condition arising from dissolved gases coming out of into bubbles inside the body on depressurisation

● Dive time : Time spent under water.

● EAN : Enriched air nitrox.

● NITROX : refers to any gas mixture composed (excepting trace gases) of nitrogen and oxygen.

● Repetitive dive : refers to dives with enough surface intervals to release the residual Nirtrogen within the body.

● Residual nitrogen : Remaining Nitrogen within the body after a dive.

● Surface interval time : Time after exiting water.

18 Accessories

Changing

All quick release type accessories can be changed accordingly

flip the CYANO-RF Pull the release bar separate the strap from the body

fit the bar into the hole first while holding the bar in place let go of the bar fit the other side into the other hole to see fitness

Different Accessories

Silicon Band

Black Strap White Strap Mint Strap Pink Strap

Leather Band

Black Strap Light Brown Strap

Body Protector

Pendant Connector White Black Glass Protector D-Ring Connector

19