LP® SHED ASSEMBLY INSTRUCTIONS | POPPY COURT 10'x12' GAMBREL SHED

1. Refer to Poppy Court 10'x12' Gambrel Roof Shed plans for actual lumber dimensions and details. 2. Refer to lpshed.com for additional application and installation details to help build your shed.

Shed images are for illustrative purposes only. Louisiana-Pacific Corporation (LP) has provided the shed designs described as a general guide to those who are interested in building sheds or in having a shed built. We do not claim that the designs or that the materials we describe are correct or the only options you have. LP has prepared each design in an attempt to satisfy generally accepted building rules and regulations. However, the designs were created without any knowledge of local conditions or geographic variables. Specific soil conditions, snow loads, wind loads, frost depth and materials will vary and may require modifications. LP cannot assure that the structures made using our designs meet your local conditions or local building code requirements. Local laws may require a permit. You are responsible for verifying that the design you choose conforms to your local building code. We strongly recommend that you: (a) contact a licensed contractor for detailed plans and construction advice; (b) contact a local building official to verify that the design meets your code requirements; and (c) check your neighborhood covenants before starting a shed project so that you can determine the appropriate size, location and approvals needed for a shed. LP is not responsible for changes made to a design. LP does not perform construction supervision and is not responsible for verifying that construction conforms to a design. LP is not responsible for how the construction work is performed including methods, sequences, techniques or procedures of construction. LP is not responsible for site safety. LP makes no representations or warranties of any kind, express or implied, relating to the completeness, accuracy, reliability, suitability or availability of the designs or materials shown here. Without limiting the prior sentence, we specifically disclaim the implied warranties of merchantability and fitness for a particular purpose to the extent allowed under applicable state laws. Any reliance you place on the information in this plan is at your own risk. You agree that LP will not be liable for any loss, damage or injury arising from the use of the designs and the materials described in this plan, whether such loss, damage or injury is claimed to be directly, indirectly, consequentially or incidentally caused by LP. You agree and acknowledge that the sole and exclusive remedy of any such claim, including attorneys’ fees and costs, shall not exceed $100.00.

FPO BEFORE YOU START

MATERIALS LIST HARDWARE LIST

MINIMUM MINIMUM DESCRIPTION DESCRIPTION QUANTITIES QUANTITIES

6 8x8x16 cmu blocks 8 Angle brackets for 6x6 platform beams

30 2x4x8' wall studs 150 Screws for platform flooring

4 4x4x8' corner posts 400 Nails for wood stud wall framing

16 2x6x8' roof 400 Nails for wall panel siding and trim

1 2x10x8' ridge beam 200 Nails for roof panels

12 2x4x8' studs for horizontal/vertical blocking Door and window hardware by Owner

12 2x4x10' studs for top & bottom plates

12 2x6x8' floor

2 2x6x12' rim joists for floor members

2 6x6x12' platform beams

8 2x4x4' studs for vertical end wall studs

50 lf Metal flashing

3 2'-0"x3'-0" windows (by Owner)

1 pair 2'-0"x6'-8" doors (by Owner)

120 sf LP® ProStruct® floor panels*

550 sf LP® SmartSide® siding panels

250 sf LP® ProStruct® Roof Sheathing with SilverTech®**

315 lf 1x4 LP® SmartSide® trim boards

250 sf Roofing material (by Owner)

*If this product is unavailable, you can substitute LP® TopNotch® Sub-Flooring. 2 **If this product is unavailable, you can substitute LP® TechShield® Radiant Barrier Sheathing or LP® OSB sheathing. FOUNDATION

1. Most buildings of less than 120 square feet do not require a building permit 1 2x10 BLOCKING BETWEEN from the local building department, but be sure to check with your local GAMBREL TRUSSES 4x4 RIDGE SUPPORT

authorities before starting construction. 12 12 7 OWNER-SUPPLIED ROOFING 7 MATERIALS 2. Contact your local building department to locate existing underground 2 1'-7" LP PROSTRUCT ROOF utility lines for you. You don’t want to disturb or hit any lines while preparing SHEATHING WITH SILVERTECH

your foundation. 1/2" PLYWOOD DOGLEG BRACE 12 3. Refer to the LP website lpshed.com/advice/buildshedfoundation for more 16 (2)2x6 BOTTOM CHORD 12 LP SMARTSIDE PANEL SIDING 3 OF GAMBREL TRUSS 16 detailedWINDOW instruction ASSEMBLY BY OWNER on how to prep and ready your site for the shed foundation. RIPPED 2x6 BLOCKING BETWEEN RAFTERS Important: The shed needs to sit on a stable/level surface, enabling the doors 3'-1 3/8" 1x4 LP SMARTSIDE TRIM BOARD LP SMARTSIDE TRIM BOARDS to work properly. 2x4 TOP PLATE (2)2x4 SILL LP SMARTSIDE PANEL SIDING METAL DRIP EDGE FLASHING 4. The shed floor also needs to sit at least 6" above the surrounding ground, 1'-0"

7 1/8" FLASHING ABOVE ALL HORIZ. for proper rainwater drainage and to prevent the shed from absorbing any LP SMARTSIDE TRIM BOARDS standing rainwater. Detail 4 Scale: 1 1/2" = 1'-0" 3'-0" LP SMARTSIDE PANEL SIDING

2x4 STUDS @ 16" O.C. 4 2x4 WINDOW FRAMING

LP PROSTRUCT FLOOR PANEL

2x4 BOTTOM PLATE LP SMARTSIDE PANEL SIDING LP SMARTSIDE PANEL SIDING

FLASHING 2'-11" 2x4 FRAMING STUDS @ 16" O.C. 5 1/2" 2x6 FLOOR JOISTS 5 LP PROSTRUCT FLOOR PANEL 1x4 LP SMARTSIDE TRIM BOARD FINISHED FLOOR 2x6 TREATED FLOOR JOISTS @ 16" O.C. Z-FLASHING FLASHING ABOVE ALL HORIZONTAL

5 1/2" LP SMARTSIDE TRIM BOARDS

6x6 TREATED PLATFORM BEAM TREATED 6x6 PLATFORM FINISHED GRADE FINISHED GRADE FOUNDATION BY OWNER

Cross-Section 8x8x16 CMU FOOTING Scale: 1/2" = 1'-0" Detail 5 Scale: 1 1/2" = 1'-0"

NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials. Please refer to "lpshed.com" for additional application and Poppy Court NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. installation details to help build your shed. 10'x12' Gambrel Roof A5 For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials.

Please refer to "lpshed.com" for additional application and Poppy Court 3 installation details to help build your shed. 10'x12' Gambrel Roof A7 SHED PLATFORM/FLOORING

10'-0" 1. Lay out the perimeter of the shed, either with a stringline or with stakes 4'-0" 2'-0" EST. 4'-0" marking the corners. ENDWALL 2x4 STUD 2'-0"x3'-0" WINDOW LP SMARTSIDE 3 1/2" 2. This shed will rest on an assembly of 6x6 and 2x6 wood framing members. 3/4" TRIM BOARDS 4x4 CORNER

5 1/2" POSTS

3" 3 1/2" 3. Install (6) 8"x8"x16" concrete masonry units (cmu’s) at the corners and 1'-0 3/8" 1'-4" 1'-1 1/8" 3" 2'-0" 3" 1'-1 1/8" 1'-4" 1'-0 3/8" 3 1/2" mid-span of the 12' length of 6x6 platform. Be sure the cmu’s are level 5 1/2" and straight in line with the overall dimensions of this 10'x12' shed.

4. Lay the 6x6’s across the 3 cmu’s on each side of the shed. Test and adjust 5'-0" 1'-10 1/4"

as needed for levelness and squareness. To achieve squareness, measure 1'-4" diagonally from corner to opposite corner of the 6x6’s. You can adjust this as you build the platform.

1'-3 1/4" (2)2x4 WINDOW 5. Cut WINDOWand install ASSEMBLY the BY OWNER 2x6 floor joists at 16" on center, attach to the 6x6’s with lag BLOCKING 8x8x16 CMU FOUNDATION 3" bolts and washers or with joist hangers. Adjust the diagonal measurements BLOCK 1x4 LP SMARTSIDE TRIM BOARD 2'-0"x3'-0" WINDOW until they are equal. The platform framing will then be square. BY OWNER (2)2x4 SILL 2'-0" LP SMARTSIDE PANEL SIDING 12'-0" 2'-0"x3'-0" 2'-0" EST. 6. Install sheets of LP® ProStruct® floor panels following the LP ProStruct Flooring WINDOW

installation instructions found at lpcorp.com/resources/product-literature. 3" Be sure to stagger the seams between floor panels so 4 corners of 4 panels do LP SMARTSIDE not meet.Detail PANEL SIDING 1'-3 1/4" 4 Scale: 1 1/2" = 1'-0"

1'-4" 2x4 STUDS @ 2x4 STUDS @ 16" O.C. 5'-0" 16" O.C. (MIN.)

LP PROSTRUCT FLOOR PANEL 8x8x16 CMU FOUNDATION (2)2x4 DOOR BLOCK 2x4 BOTTOM PLATE BLOCKING

LP SMARTSIDE PANEL SIDING 1'-10 1/4"

FLASHING 5 1/2" 2x6 FLOOR JOISTS 3 1/2" 1x4 LP SMARTSIDE TRIM BOARD (2)2'-0"x6'-8" DOORS & FRAME Z-FLASHING BY OWNER 5 1/2" 2'-11 1/4" 4'-1 1/2" ESTIMATED 2'-11 1/4" 6x6 TREATED PLATFORM BEAM

FINISHED GRADE 10'-0"

8x8x16 CMU FOOTING Floor Plan Scale: 1/2" = 1'-0" Detail 5 Scale: 1 1/2" = 1'-0" NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials. Please refer to "lpshed.com" for additional application and Poppy Court installation details to help build your shed. 10'x12' Gambrel Roof A14

NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials. Please refer to "lpshed.com" for additional application and Poppy Court installation details to help build your shed. 10'x12' Gambrel Roof A7 WALLS

1. Lay out the (2) 4x4 corner posts and 2x4 studs (at 16" on center) on the shed 1 2x10 BLOCKING BETWEEN floor. Use the shed floor as a guide to constructing your walls, since the floor is GAMBREL TRUSSES 4x4 RIDGE SUPPORT

level and square. 12 12 7 OWNER-SUPPLIED ROOFING 7 MATERIALS 2. When framing window and door openings, use 2 2x4 studs on each side of 2 1'-7" LP PROSTRUCT ROOF the openings. SHEATHING WITH SILVERTECH

1/2" PLYWOOD DOGLEG BRACE 3. Secure the ends of the posts and studs with 2x4 top and bottom stud plates at 12 each end. Drive screws through these top and bottom plates into the posts and 16 (2)2x6 BOTTOM CHORD 12 LP SMARTSIDE PANEL SIDING 3 OF GAMBREL TRUSS 16 studs to hold them in place. We will be adding a second top plate member after RIPPED 2x6 BLOCKING BETWEEN RAFTERS 3'-1 3/8" all walls are erected. LP SMARTSIDE TRIM BOARDS 2x4 TOP PLATE 4. Install the horizontal cross bracing/blocking between the studs with 2x4’s cut METAL DRIP EDGE FLASHING to length. 1'-0"

7 1/8" FLASHING ABOVE ALL HORIZ. LP SMARTSIDE TRIM BOARDS 5. Continuously measure the wall to be sure it is square.

6. After the studs and corner posts are secured to the top and bottom plates, raise the wall into place on the shed floor. Attach 2x4 diagonal bracing to the 3'-0" LP SMARTSIDE PANEL SIDING top of the wall at each end. Use a level to determine that the corner posts are perfectly plumb and vertically square. Once square, screw the diagonal brace 4 2x4 WINDOW FRAMING to the outside face of the platform to hold the wall in place.

7. Construct the remaining 3 walls in a similar fashion, making sure to frame LP SMARTSIDE PANEL SIDING

properly for all appropriate openings in the walls. Allow the shorter 10' end 2'-11" 2x4 FRAMING STUDS walls to rest within the corner posts. Temporarily hold these walls in place @ 16" O.C. with diagonal bracing. 5 LP PROSTRUCT FLOOR PANEL FINISHED FLOOR 2x6 TREATED FLOOR JOISTS @ 16" O.C. FLASHING ABOVE ALL HORIZONTAL 8. Before continuing, re-measure all corners and walls, making sure all are level LP SMARTSIDE TRIM BOARDS and plumb as needed. TREATED 6x6 PLATFORM FINISHED GRADE

9. Attach 2x4 top plates to the tops of the wall assembly. Overlap the joints FOUNDATION BY OWNER where the walls come together with the top plates. Continue installation of these top plates all around the perimeter of the walls. Cross-Section Scale: 1/2" = 1'-0"

NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials. Please refer to "lpshed.com" for additional application and Poppy Court installation details to help build your shed. 10'x12' Gambrel Roof A5

5 ROOF RAFTERS

1. The rafters meet at the top and are secured to the 2x10 ridge beam. You will 1 2x10 BLOCKING BETWEEN have to temporarily brace the ridge beam at the height required. Use a piece of GAMBREL TRUSSES 4x4 RIDGE SUPPORT

4x4 to support the ridge beam. 12 12 7 OWNER-SUPPLIED ROOFING 7 MATERIALS 2. The 2x6 roof rafters have small notches (“birds-mouth”) cut into them which 2 1'-7" LP PROSTRUCT ROOF allow them to sit on the top plates of the walls. Cut out these notches on the SHEATHING WITH SILVERTECH

dimensions shown on the Details in the shed plan. Make another angle cut at 1/2" PLYWOOD DOGLEG BRACE the end of the to fit onto the ridge beam. Refer to the Details on the 12 16 (2)2x6 BOTTOM CHORD 12 LP SMARTSIDE PANEL SIDING shed plan for these dimensions. Use a power saw to cut the majority of the 3 OF GAMBREL TRUSS 16 RIPPED 2x6 BLOCKING rafters, and finish the cuts with a handsaw. BETWEEN RAFTERS 3'-1 3/8" LP SMARTSIDE TRIM BOARDS 3. If the bottom end of the rafter shows a decorative “raftertail,” cut out 2x4 TOP PLATE according to the Details on the shed plan. METAL DRIP EDGE FLASHING 1'-0"

7 1/8" FLASHING ABOVE ALL HORIZ. 4. Make 2 roof rafters. Test-fit them on the walls and ridge beam. Adjust and LP SMARTSIDE TRIM BOARDS re-cut as needed for a tight fit. Once a good fit is established, these rafters will act as a template for the remaining rafters. Simply place this rafter template on the remaining 2x6’s, mark and cut as needed. But, it’s always good practice 3'-0" LP SMARTSIDE PANEL SIDING to test-fit as you go.

4 2x4 WINDOW FRAMING 5. Once all the rafters are cut, mark their locations on the tops of the walls. Refer to the drawings for locations of rafters and outlookers members.

LP SMARTSIDE PANEL SIDING 6. Start the assembly by setting pairs of rafters at the ends of the building.

Adjust the ridge beam as needed so all are straight, level and plumb. Then, 2'-11" 2x4 FRAMING STUDS install the remaining rafters, making sure all fits are tight. Attach with screws @ 16" O.C. LP PROSTRUCT FLOOR PANEL angled through the rafters into the top plates of the walls. 5 FINISHED FLOOR 2x6 TREATED FLOOR JOISTS @ 16" O.C. FLASHING ABOVE ALL HORIZONTAL LP SMARTSIDE TRIM BOARDS TREATED 6x6 PLATFORM FINISHED GRADE

FOUNDATION BY OWNER

Cross-Section Scale: 1/2" = 1'-0"

NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials. Please refer to "lpshed.com" for additional application and Poppy Court installation details to help build your shed. 10'x12' Gambrel Roof A5

6 ROOF DECK

1. We will be using the LP® ProStruct® Roof Sheathing with SilverTech®. Cut 1 2x10 BLOCKING BETWEEN sheets as needed to fit the overall size of the roof. Fasten to each roof rafter GAMBREL TRUSSES 4x4 RIDGE SUPPORT

and outrigger following the roof sheathing installation instructions found at 12 12 lpcorp.com/resources/product-literature. 7 OWNER-SUPPLIED ROOFING 2 7 MATERIALS 1'-7" LP PROSTRUCT ROOF 2. Depending on the type of roofing finish you put on the shed, follow that roof SHEATHING WITH SILVERTECH

manufacturer’s nailing instruction for proper installation. To accommodate 1/2" PLYWOOD DOGLEG BRACE longer recommended nail lengths, you may have to add a layer of ½" oriented 12 16 (2)2x6 BOTTOM CHORD 12 LP SMARTSIDE PANEL SIDING strand board (OSB) on top of the LP ProStruct Roof Sheathing with SilverTech. 3 OF GAMBREL TRUSS 16 RIPPED 2x6 BLOCKING Then, install the finished roof and materials as recommended by BETWEEN RAFTERS 3'-1 3/8" the manufacturer. LP SMARTSIDE TRIM BOARDS 2x4 TOP PLATE METAL DRIP EDGE FLASHING 1'-0"

7 1/8" FLASHING ABOVE ALL HORIZ. LP SMARTSIDE TRIM BOARDS

3'-0" LP SMARTSIDE PANEL SIDING

4 2x4 WINDOW FRAMING

LP SMARTSIDE PANEL SIDING

2'-11" 2x4 FRAMING STUDS @ 16" O.C. 5 LP PROSTRUCT FLOOR PANEL FINISHED FLOOR 2x6 TREATED FLOOR JOISTS @ 16" O.C. FLASHING ABOVE ALL HORIZONTAL LP SMARTSIDE TRIM BOARDS TREATED 6x6 PLATFORM FINISHED GRADE

FOUNDATION BY OWNER

Cross-Section Scale: 1/2" = 1'-0"

NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials. Please refer to "lpshed.com" for additional application and Poppy Court installation details to help build your shed. 10'x12' Gambrel Roof A5

7 COMPLETING THE EXTERIOR

1. Re-measure the window and door rough opening, to assure a good fit with the window frame. Adjust your rough framing as needed to properly accept the window and door frames.

12 12 2. Install the windows as per the window manufacturer you selected to use. Be 7 7 2'-2" ROOF MATERIALS (BY OWNER) ON 30# FELTS ON LP PROSTRUCT ROOF sure to include a length of metal flashing along the top of horizontal window SHEATHING WITH SILVERTECH trims. Refer also to the Details on the shed plans. Install window hardware. 2x6 GAMBREL TRUSS FASCIA

LP SMARTSIDE PANEL SIDING W/ 8" OR 4" (SHOWN) O.C. 3. Install the door frame and door as per its manufacturer. Be sure to include a 12 12 VERTICAL GROOVES length of metal flashing along the top of horizontal door trims. Shim the frame 16 16 2'-3 3/8" as needed to assure that it’s plumb. Install the doors on their hinges. Install the FLASHING ABOVE ALL HORIZONTAL door hardware. LP SMARTSIDE TRIM BOARDS

4. Install the LP® SmartSide® panel siding, along with the LP® SmartSide® 8 1/4" trim boards following the LP® SmartSide® installation instructions found at

lpcorp.com/resources/product-literature. Use 8" o.c. grooved, vertical panels 1'-0" LP SMARTSIDE TRIM BOARDS for the lower section of the gable wall ends, and use 4" o.c. grooved, vertical

siding panels above the trim boards to the studs. Be sure to include a length of LP SMARTSIDE PANEL SIDING W/ 8" (SHOWN) OR 4" O.C. metal flashing along the top of horizontal trim pieces and panel seams. VERT. GROOVES

(2)2'-0"x6'-8" DOORS W/ 5. Finish the exterior of the shed with materials of your choice. Be sure to LP SMARTSIDE TRIM BOARDS 6'-8" follow the manufacturer’s installation instructions for proper application and maintenance of your finishes.

FINISHED FLOOR

FLASHING ABOVE ALL HORIZONTAL LP SMARTSIDE TRIM BOARDS

FINISHED GRADE

CMU FOUNDATION BLOCKS

Front Elevation Scale: 1/2" = 1'-0"

NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials. Please refer to "lpshed.com" for additional application and Poppy Court installation details to help build your shed. 10'x12' Gambrel Roof A2 8 COMPLETING THE EXTERIOR (CONT.)

ROOF MATERIALS (BY OWNER) ON 30# FELTS ON LP PROSTRUCT ROOF SHEATHING WITH SILVERTECH 2'-2" ROOF MATERIALS (BY 12 OWNER) ON 30# FELTS 12 ROOF MATERIALS (BY ON LP PROSTRUCT ROOF 7 OWNER) ON 30# FELTS ON SHEATHING WITH SILVERTECH 7 LP PROSTRUCT ROOF 2'-2" 2'-2" SHEATHING WITH SILVERTECH

2x6 GAMBREL TRUSSES @ 24" O.C.

FLASHING ABOVE ALL LP SMARTSIDE PANEL SIDING HORIZONTAL LP SMARTSIDE W/ 8" OR 4" (SHOWN) O.C. 12 VERTICAL GROOVES 3'-1 1/2" TRIM BOARDS 16 12 FLASHING ABOVE ALL HORIZONTAL 2x6 GAMBREL TRUSSES @

2'-3 3/8" LP SMARTSIDE TRIM BOARDS FLASHING24" O.C. ABOVE ALL 16 HORIZONTAL LP SMARTSIDE

3'-1 1/2" TRIM BOARDS

2x6 GAMBREL TRUSSES @ 24" O.C. 6 1/8"

1'-0"

LP SMARTSIDE TRIM BOARDS 1'-4 1/4" 6 1/8" LP SMARTSIDE TRIM BOARDS 1'-0" LP SMARTSIDE PANEL SIDING 1'-0" LPW/ SMARTSIDE 8" (SHOWN) TRIM OR 4" BOARDS O.C. VERT. GROOVES

LP SMARTSIDE PANEL SIDING LP SMARTSIDE PANEL SIDING W/2'-0"x3'-0" 8" (SHOWN) WINDOW OR 4" W/ O.C. W/ 8" (SHOWN) OR 4" O.C. VERT.LP SMARTSIDE GROOVES TRIM BOARDS VERTICAL GROOVES 6'-0"

2'-0"x3'-0" WINDOW W/ 2'-0"x3'-0" WINDOW W/ LP SMARTSIDE TRIM BOARDS LP SMARTSIDE TRIM BOARDS 6'-0" 6'-0"

FINISHED FLOOR FLASHING ABOVE ALL HORIZONTAL LP SMARTSIDE TRIM BOARDS FINISHED FLOOR FINISHED FLOOR FINISHED GRADE FLASHING ABOVE ALL FLASHING ABOVE ALL HORIZONTAL HORIZONTAL LP SMARTSIDE LP SMARTSIDE TRIM BOARDS TRIM BOARDS CMU FOUNDATION BLOCK FINISHED GRADE FINISHED GRADE

CMU FOUNDATION BLOCK CMU FOUNDATION BLOCK

Left & Right Side Elevations Rear Elevation Scale: 1/2" = 1'-0" Scale: 1/2" = 1'-0" NOTE: Refer to "LPSHED.com/advice/buildshedfoundation"Left & Right Side Elevations for all site prep information. For exclusive useScale: with 1/2" all = 1'-0" LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials. NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prepPoppy information. Court Please refer to "lpshed.com" for additional application and NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. installationFor exclusive details use to with help all build LP®SMARTSIDE®, your shed. LP®PROSTRUCT®, and LP®SILVERTECH®building10'x12' Gambrel Roof materials.A3 For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials. Please refer to "lpshed.com" for additional application and Poppy Court installation details to help build your shed. 10'x12' Gambrel Roof A3 Please refer to "lpshed.com" for additional application and Poppy Court installation details to help build your shed. 10'x12' Gambrel Roof A4 9 DETAILS

OWNER-SUPPLIED ROOFING MATERIALS

LP PROSTRUCT ROOF SHEATHING WITH SILVERTECH

2x10 BLOCKING BETWEEN GAMBREL OWNER-SUPPLIED ROOFING TRUSSES MATERIALS LP PROSTRUCT ROOF 2x6's GAMBREL TRUSS SHEATHING WITH SILVERTECH

1/2" PLYWOOD DOGLEG 4x4 SUPPORT BRACE

2x6's GAMBREL TRUSS WINDOW ASSEMBLY BY OWNER

1x4 LP SMARTSIDE TRIM BOARD

(2)2x4 SILL LP SMARTSIDE PANEL SIDING Detail @ Ridge Detail @ Roofbreak 1 2 Scale: 1 1/2" = 1'-0" Scale: 1 1/2" = 1'-0" Detail 4 Scale: 1 1/2" = 1'-0"

OWNER-SUPPLIED ROOFING MATERIALS 2x4 STUDS @ 16" O.C.

LP PROSTRUCT ROOF SHEATHING 2x6 BLOCKING BETWEEN RAFTERS LP PROSTRUCT FLOOR PANEL WITH SILVERTECH 2x4 TOP PLATE 2x4 BOTTOM PLATE 1x4 LP SMARTSIDE TRIM BOARD LP SMARTSIDE PANEL SIDING LP SMARTSIDE PANEL SIDING FLASHING

2x4 STUDS @ 16" O.C. 5 1/2" 2x6 FLOOR JOISTS 2x6 ROOF RAFTERTAIL 1'-0" 3 1/2" 1x4 LP SMARTSIDE TRIM BOARD Z-FLASHING METAL DRIP FLASHING UNDER OWNER-SUPPLIED ROOFING 5 1/2" 6x6 TREATED PLATFORM BEAM LP SMARTSIDE PANEL SIDING (2)2x4 HEADER FINISHED GRADE FLASHING

1x4 LP SMARTSIDE TRIM BOARD (SET 3/8" ABOVE WINDOW FRAME)

Z-FLASHING 8x8x16 CMU FOOTING WINDOW ASSEMBLY BY OWNER Detail 5 Scale: 1 1/2" = 1'-0"

Detail 3 Scale: 1 1/2" = 1'-0"

NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. NOTE: Refer to "LPSHED.com/advice/buildshedfoundation" for all site prep information. For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials.For exclusive use with all LP®SMARTSIDE®, LP®PROSTRUCT®, and LP®SILVERTECH®building materials. Please refer to "lpshed.com" for additional application and Poppy Court Please refer to "lpshed.com" for additional application and Poppy Court 10 installation details to help build your shed. 10'x12' Gambrel Roof installationA6 details to help build your shed. 10'x12' Gambrel Roof A7