Design Considerations of LED Based Visible Notification Appliances
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
11L Visual Signaling Devices ''Steady On'' Beacons, ''Rotating'' Beacons and ''Flashing'' Strobe Lights
2: 5: 50: 95: 98: 100: SYS19: BASE2 JOB: CRMAIN06-0939-6 Name: 11L-939 DATE: JAN 19 2006 Time: 6:02:54 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100 2 Visual Signaling Devices 11L ‘‘Steady On’’ Beacons, ‘‘Rotating’’ Beacons and ‘‘Flashing’’ Strobe Lights Luminaires for Hazardous and Non-Hazardous Locations Description Page No. Application 940 VF Beacons Fluorescent ‘‘Steady On’’ 941 EX Fire Alarm Strobe Light 942, 944, 949 EX Strobe Light 943, 944, 949 EX Steady-on Beacon 945, 946, 949 EX Rotating Beacon 947, 948, 949 VDAS Strobe Lights 950 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 939 STIBOINFO((CRH:66008com:11L:939)) PDFINFO C H 0 0 0 0 8 L 2: 5: 50: 95: 98: 100: SYS19: BASE2 JOB: CRMAIN06-0940-9 Name: 11L-940 DATE: JAN 19 2006 Time: 6:02:55 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100 11L Visual Signaling Devices ‘‘Steady On’’ Beacons, ‘‘Rotating’’ Beacons and ‘‘Flashing’’ Strobe Lights Luminaires for Hazardous and Non-Hazardous Locations Application: Considerations for ɀ for use in hazardous and non-hazardous Selection: areas (as shown in the quick selector chart Environmental: shown below). ɀ What is the hazardous area classification ɀ to supplement audible signals, especially in (NEC/CEC) of the location in which the high noise areas. luminaire will be installed? ɀ as visual signals or warning lights. ɀ Signaling Requirements: to identify the location of safety equipment ɀ such as emergency shower, eye wash What will the visual signal be used for stations, and emergency telephones, fire (Communicating, alerting, warning)? extinguishers and emergency stop switches. -
Zipka® Plus2
TIKKA - ZIPKA headlamps New lighting performance ZIPKA® PLUS2 Selling points Product specifications • Compact, light and comfortable: Weight: 71 g Ultra-compact headlamp with - 25 % more compact than the TIKKA PLUS2 headlamp Beam pattern: wide retractable cord, 1 high-output LED, - single compartment contains LEDs and batteries Max. light quantity: 70 lumens - ZIP retractable cord is adjustable Max. lighting distance: 40 m 1 red LED and five lighting modes • Versatile and powerful: Max. battery life: 155 h (three continuous and two blinking) - three white lighting modes (maximum, economic and Number of batteries: 3 strobe) Battery type (included): AAA/LR03 The ultra-compact ZIPKA PLUS2 headlamp - two red lighting modes: maximum and strobe Battery compatibility: alkaline, lithium, rechargeable Ni-MH, is equipped with the ZIP retractable cord - type of lighting (white or red) is selected by pressing rechargeable Ni-Cd for two seconds on the push-button (the last mode used Watertightness: IP X4 (water resistant) system. This feature allows the headlamp to remains in the memory until the next use) Certification(s): CE be worn on the head or wrist, or attached to • One high-output white LED: any other support, like a tent pole, a bicycle - 70 lumens (maximum mode) Accessories - shines up to 40 meters (maximum mode) seat post, etc. This headlamp integrates - 155 h light duration on economic mode POCHE ZIPKA®2: E94990 two light sources for versatility: one white, - specific Petzl lens optimizes the reach of the beam and KIT ADAPT TIKKA®2: E97900 maximizes versatility CORE: E93100 high-output LED and one red LED. The white • Easy to use: LED delivers 70 lumens in maximum mode - electronic push-button switch and lights up to 40 meters. -
Chapter 347 Equipment of Vehicles
Updated 2013−14 Wis. Stats. Published and certified under s. 35.18. January 1, 2015. 1 Updated 13−14 Wis. Stats. EQUIPMENT OF VEHICLES 347.02 CHAPTER 347 EQUIPMENT OF VEHICLES SUBCHAPTER I 347.28 Certain vehicles to carry flares or other warning devices. GENERAL PROVISIONS 347.29 Display of warning devices for certain vehicles when standing on highway. 347.01 Words and phrases defined. 347.30 Penalty for violating lighting equipment requirements. 347.02 Applicability of chapter. SUBCHAPTER III 347.03 Sale of prohibited equipment unlawful. OTHER EQUIPMENT 347.04 Owner responsible for improperly equipped vehicle. 347.35 Brakes. 347.05 Reciprocity agreements as to equipment. 347.36 Performance ability of brakes. SUBCHAPTER II 347.37 Brake fluid, sale regulation. LIGHTING EQUIPMENT 347.38 Horns and warning devices. 347.06 When lighted lamps required. 347.385 Auxiliary lamps on emergency vehicles; traffic control signal emergency 347.07 Special restrictions on lamps and the use thereof. preemption devices. 347.08 Determining the visibility distance and mounted height of lamps. 347.39 Mufflers. 347.09 Headlamps on motor vehicles. 347.40 Mirrors. 347.10 Headlamp specifications for motor vehicles other than mopeds and motor 347.41 Speed indicators. bicycles. 347.413 Ignition interlock device tampering; failure to install. 347.11 Headlamp specifications for mopeds and motor bicycles. 347.415 Odometer tampering. 347.115 Modulating headlamps for motorcycles, motor bicycles or mopeds. 347.417 Immobilization device tampering. 347.12 Use of multiple−beam headlamps. 347.42 Windshield wipers. 347.13 Tail lamps and registration plate lamps. 347.43 Safety glass. 347.14 Stop lamps. -
29 Light Bulbs 29
PARTS CATALOG FOR SCHOOL BUSES AND MORE! © 2013 Blue Bird Body Company. All rights reserved. PARTS CATALOG FOR SCHOOL BUSES AND MORE! Thank you for choosing Blue Bird…and Blue Bird parts! As a seller of the most recognized and trusted brand in student transportation vehicles, your nearest Blue Bird Authorized Dealer is your best source for original equipment and aftermarket parts to keep your fleet in top shape. Your Blue Bird Dealer is staffed with true school bus parts experts; and the Parts and Service team at the Blue Bird home plant in Fort Valley, GA partners with industry leading component manufacturers to bring you top quality at competitvely attractive prices. Many of the leading-brand components used in the assembly of Blue Bird buses also occur in a broad range of medium duty truck applications, as well as other brand school buses. And that’s what this catalog is all about. We hope you’ll keep it handy as a quick lookup tool for many of the most frequently-needed replacement parts for your Blue Bird buses, other brand school buses, and even for other vehicles you may service in your facility. Just browse the catalog for the Item To Order numbers you need, contact your Blue Bird Dealer for current pricing, and we’ll take care of the rest. Blue Bird’s state-of-the-art Parts Distibution Center provides over 2.1 million cubic feet of clean, modern storage for over 40,000 items (and growing). And our business partnerships enable us to ship many more items to you directly from the manufacturers’ warehouses, saving you time and money. -
LFC-050-LE Light Flux Color and Luminous Efficacy Measurement Systems Why Choose Lightfluxcolor
LFC-050-LE Light Flux Color and Luminous Efficacy Measurement Systems Why Choose LightFluxColor • Calibrations are traceable to NIST (USA) which are accepted and recognized globally. Ideal For Flux, Color & AC/DC The most economical and • Calibrated lamp standards NVLAP Electrical Characterization of: reliable solution for photometry accreditation Lab Code 200951-0 of light source needs! Automotive Lamps Traffic Lighting (ISO 17025) LED Clusters Architectural Lighting • Spectral flux standards (calibration LightFluxColor-LE Series Systems are the performed at each wavelength) are LED Bulbs Railway Lighting most affordable and reliable systems for testing supplied with each system for highest LED lighting products. Whether you are a possible accuracy. manufacturer of LED luminaires, street lights, • Single software controls all electronics and solar powered LED lanterns, LED bulbs, LightFluxColor-LE Series Systems also include provides optical and electrical data. or any other type of LED lighting product, a highly sensitive mini-calibrated CCD Array Spectrometer with spectral range from LightFluxColor Systems will meet all your testing • Competitive systems only provide 250 to 850 nm. This low noise and broad spectral requirements. LightFluxColor Systems allow luminous flux standards with CCT luminaire manufacturers to test LED products response spectrometer provide instantaneous calibration which limits overall for photometric performance. measurement of radiometric, photometric, and system accuracy. color characteristics of the LED sources. • AC/DC operation in one packaged LightFluxColor-LE Series Systems allow testing system users to test AC/DC characterization of lamps The fast results from the spectrometer helps at various input frequencies along with lumens to increase the rate of product development, • An auxiliary lamp is provided for and color parameters. -
Energy Efficiency – HID Lighting
PDHonline Course E423 (5 PDH) Energy Efficiency High Intensity Discharge Lighting Instructor: Lee Layton, P.E 2014 PDH Online | PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.PDHonline.org www.PDHcenter.com An Approved Continuing Education Provider www.PDHcenter.com PDHonline Course E423 www.PDHonline.org Energy Efficiency High Intensity Discharge Lighting Lee Layton, P.E Table of Contents Section Page Introduction ………………………………….….. 3 Chapter 1, Lighting Market ………………….….. 5 Chapter 2, Fundamentals of Lighting ………….... 16 Chapter 3, Characteristics of HID Lighting……... 28 Chapter 4, Types of HID Lighting……………..... 37 Summary ……………………………………..…. 66 © Lee Layton. Page 2 of 66 www.PDHcenter.com PDHonline Course E423 www.PDHonline.org Introduction Gas-discharge lamps are light sources that generate light by sending an electrical discharge through an ionized gas. The character of the gas discharge depends on the pressure of the gas as well as the frequency of the current. High-intensity discharge (HID) lighting provides the highest efficacy and longest service life of any lighting type. It can save 75%-90% of lighting energy when it replaces incandescent lighting. Figure 1 shows a typical high-intensity discharge lamp. In a high-intensity discharge lamp, electricity arcs between two electrodes, creating an intensely bright light. Usually a gas of mercury, sodium, or metal halide acts as the conductor. HID lamps use an electric arc to produce intense light. Like fluorescent lamps, they require ballasts. They also take up to 10 minutes to produce light when first turned on because the ballast needs time to establish the electric arc. -
Illumination Fundamentals
Illumination Fundamentals The LRC wishes to thank Optical Research Associates for funding this booklet to promote basic understanding of the science of light and illumination. Project Coordinator: John Van Derlofske Author: Alma E. F. Taylor Graphics: Julie Bailey and James Gross Layout: Susan J. Sechrist Cover Design: James Gross Technical Reviewers: Dr. Mark Rea and Dr. John Van Derlofske of the Lighting Research Center; Dr. William Cassarly and Stuart David of Optical Research Associates. Table 2.1 and Figures 2-3 and 2-5 are from Physics for Scientists and Engineers, copyright (c) 1990 by Raymond A. Serway, reproduced by permission of Harcourt, Inc. No portion of this publication or the information contained herein may be duplicated or excerpted in any way in other publications, databases, or any other medium without express written permission of the publisher. Making copies of all or part of this publication for any purpose other than for undistributed personal use is a violation of United States copyright laws. © 2000 Rensselaer Polytechnic Institute. All rights reserved. Illumination Fundamentals 3 Contents 1. Light and Electromagnetic Radiation ...................................... 7 1.1. What is Light? ................................................................... 7 1.2. The “Visible” Spectrum .................................................... 8 1.3. Ultraviolet Radiation ........................................................ 8 1.4. Infrared Radiation ............................................................ 8 2. -
Luminaire Efficacy Building Technologies Program
LED Measurement Series: Luminaire Efficacy Building Technologies Program LED Measurement Series: Luminaire Efficacy The use of light-emitting diodes (LEDs) as a general light source is forcing changes in test procedures used to measure lighting performance. This fact sheet describes the concept of luminaire efficacy and the technical reasons for its applicability to LED-based lighting fixtures. Lighting energy efficiency is a function of both the light source (the light “bulb” or lamp) and the fixture, including necessary controls, power supplies and other electronics, and optical elements. The complete unit is known as a luminaire. Traditionally, lighting energy efficiency is characterized in terms of lamp ratings and fixture Photo credit: Luminaire Testing Laboratory efficiency. The lamp rating indicates how much light (in lumens) the lamp will produce when operated at standard room/ambient temperature (25 degrees C). The luminous efficacy of a light source is typically given as the rated lamp lumens divided by the nominal wattage of the lamp, abbreviated lm/W. The fixture efficiency indicates the proportion of rated lamp lumens actually Terms emitted by the fixture; it is given as a percentage. Fixture efficiency is an appropriate measure for Photometry – the measurement fixtures that have interchangeable lamps for which reliable lamp lumen ratings are available. of quantities associated with light, However, the lamp rating and fixture efficiency measures have limited usefulness for LED including luminance, luminous lighting at the present time, for two important reasons: intensity, luminous flux, and illuminance. 1) There is no industry standard test procedure for rating the performance of LED devices or packages. -
Characterization of Gatewell Orifice Lighting at the Bonneville Dam Second Powerhouse and Compendium of Research on Light Guidance with Juvenile Salmonids
PNNL-17210 Characterization of Gatewell Orifice Lighting at the Bonneville Dam Second Powerhouse and Compendium of Research on Light Guidance with Juvenile Salmonids FINAL REPORT RP Mueller MA Simmons September 2008 PNNL-17210 Characterization of Gatewell Orifice Lighting at the Bonneville Dam Second Powerhouse and Compendium of Research on Light Guidance with Juvenile Salmonids Final Report RP Mueller MA Simmons September 2008 Prepared for the U.S. Army Corps of Engineers, Portland District, under a Government Order with the U.S. Department of Energy Contract DE-AC05-76RL01830 Pacific Northwest National Laboratory Richland, Washington 99352 Summary The study described in this report was conducted by the Pacific Northwest National Laboratory (PNNL) to provide biologist and engineers of the U.S. Army Corps of Engineers (USACE) with general design guidelines for using artificial lighting to enhance the passage of juvenile salmonids into the collection channel at the Bonneville Dam second powerhouse, managed by the USACE Portland District. The work comprised three primary objectives. The first was to review and synthesize all relevant studies in which artificial light was evaluated in a field or laboratory setting for its potential to guide fish at passage barriers within juvenile salmonid outmigration corridors. The second objective was to conduct a field study at the Bonneville Dam second powerhouse to evaluate the output levels of two artificial light sources at one orifice entrance within Gatewell 12. The third objective was to compare, in a laboratory setting, the performance of three light sources in terms of light intensity values. PNNL reviewed 36 sources in the published gray and peer-reviewed literature and prepared a synopsis that includes the study objectives, species and life stage, experimental conditions, type of lighting used, and a summary of the results. -
Final Report (2018-2019) 50 Wolf Road Albany, NY 12232 14
Authors: John D. Bullough Nicholas P. Skinner Conducted for the NEW YORK STATE DEPARTMENT OF TRANSPORTATION By the LIGHTING RESEARCH CENTER RENSSELAER POLYTECHNIC INSTITUTE 21 Union Street, Troy, NY 12180 November 2019 1. Report No. 2. Government Accession No. 3. Recipient's Catalog No. C-18-03 4. Title and Subtitle 5. Report Date EVALUATION OF LIGHT EMITTING SURFACE AND November 2019 LIGHT EMITTING DIODE ROADWAY LUMINAIRES 6. Performing Organization Code 7. Author(s) 8. Performing Organization Report No. John D. Bullough and Nicholas P. Skinner 9. Performing Organization Name and Address 10. Work Unit No. Lighting Research Center 11. Contract or Grant No. Rensselaer Polytechnic Institute 21 Union Street Troy, NY 12180 12. Sponsoring Agency Name and Address 13. Type of Report and Period Covered NYS Department of Transportation Final Report (2018-2019) 50 Wolf Road Albany, NY 12232 14. Sponsoring Agency Code 15. Supplementary Notes Rodney Delisle from the NYS Department of Transportation served as Project Manager. Project funded in part with funds from the Federal Highway Administration (FHWA). 16. Abstract In the present study, roadway luminaires using light emitting surface (LES) technology were compared in terms of photometric performance to roadway luminaires using high pressure sodium (HPS) lamps and light emitting diode (LED) sources. Measurements of light output and electrical power use revealed that the LES luminaires performed similar to the high end of the range of LED luminaires used for comparison. Spectral metrics were similar to those of LED luminaires with the same correlated color temperature (CCT). Measurements of the intensity distribution showed close correspondence with published data for roadway luminaire distributions. -
Overhead High Bay Lighting
ADD VENDORS TO FRONT www.portlandfasteners.com 1 OVERHEAD HIGH BAY LIGHTING CEP 120 WATT LED HIGH BAY FIXTURE 200 watt LED temporary work light • LED High Bay Light Outshines Metal Halides • 120% LED Efficiency • Includes a 15A Female Receptacle to daisy chain lights downstream LED 14,000 LUMENS CL120LED CEP 400 WATT METAL HALIDE SOUTHWIRE 400 WATT METAL LIGHT HALIDE LIGHT with lamp and wire guard • Heavy-duty formed steel enclosure with powder- • UL Listed, suitable for damp locations coated finish • Compact size for easy handling • Open-air ballast for cooler operation • Heavy-duty formed steel enclosed powder coated • Hook with latching feature - fixture mounts in finish seconds, no tools required METAL HALIDE REPLACEMENT BULB METAL HALIDE REPLACEMENT BULB 29,000 LUMENS 5940P CL400P 29,000 LUMENS 540P 7605SW 2 LOW BAY 15FT LOWER LIGHTING CEP 105 WATT COMPACT HANG-A-LIGHT® HANG-A-LIGHT® FLOURESCENT FIXTURE 105 WATT SPIRAL 80 WATT LED LIGHT FLOURESCENT • Covered and protected LED’s • UL/cUL for Dry LIGHT • 360° lighting Locations • No Hot Surfaces • Energy Efficient 105 watt • Welded wire safety cage • 105 Watts @ 120 Flourescent Bulb Volts = 0.87 Amps • Self-Ballasted CFL Bulb, lightweight and flicker free • Electrical Receptacle, interconnect up to 8 units • on 120V/15A service FLUORESCENT REPLACEMENT BULB FLUORESCENT REPLACEMENT BULB LED REPLACEMENT BULB 5,800 LUMENS 105WCFL CL105CFL 6,900 LUMENS 111915 111105F 8,600 LUMENS 2145 111080LED M18 RADIUSTM LED 78W TEMPORARY LED RADIUS LED 70 WATT COMPACT SITE LIGHT LOW BAY LIGHT TEMPORARY SITE LIGHT WITH ONE-KEYTM • High lumen output of 8200 lumens while consuming 78W • Survives The Job. -
How to Install This Strobe Light
IF THIS STROBE LIGHT ACTIVATES SPECIAL COMPLIANCE CONSIDERATIONS RECOMMENDED PLACEMENT FOR HEARING HOW TO INSTALL THIS STROBE LIGHT USER’S MANUAL IMPAIRED STROBE LIGHTS This Strobe Light is designed to be mounted on any standard wiring junction box to a 4-inch (10 cm) diagonal size, on either the ceiling or wall (if allowed RESPONDING TO AN ALARM According to NFPA 72, at a minimum a strobe should installed within Strobe Lights along with residential smoke and carbon monoxide by local codes). Read “Recommended Placement for Hearing Impaired Strobe Lights” before you begin installation. During an alarm, depending on what type of alarms you have alarms alone are not a suitable substitute for complete fire 16 feet (4.9 meters) of the pillow. Tools you will need: • Standard Flathead screwdriver • Wire strippers connected, the strobe light will flash different patterns. AC POWERED STROBE LIGHT detection systems in places housing many people—like apartment For wall mounting, the strobe should be between 80 to 96 inches (203 Smoke/Heat Alarms: Constant approximately 1 flash per second. buildings, condominiums, hotels, motels, dormitories, hospitals, FOR THE HEARING IMPAIRED to 244 cm) above the floor. THE PARTS OF THIS STROBE LIGHT CO Alarms: Intermittent approximately 1 flash per second for four long-term health care facilities, nursing homes, day care facilities, For ceiling mounting: Ideally, the strobe should be located near the flashes, then 5 seconds off. Pattern is repeated. or group homes of any kind—even if they were once single-family Input: 120V AC ~, 60Hz center of the room. See diagram. The Mounting Bracket homes.