No. 13, Jalan Budiman, HVLS Budiman Business Park, , 43000 , , .

+603 8741 7300 [email protected] facebook.com/AireGardMY AireGard.com there’s quality in every inch of Airegard HVLS fan

Every one of our HVLS fans is We only use world class, industrial-grade engineered to deliver the smoothest, components and the highest quality most efficient, and most precise airflow parts to ensure the most efficient, and possible. Our fan blades are made from reliable fan possible. From an investment aviation grade magnalium, making them perspective, we offer you the best-value stronger and lighter. proposition in the market.

3. Benefits of hvls fans 1 Industrial ventilation, perfect solution for personal cooling.

2 Energy saving up to 90%, compared to conventional solution.

3 Maximum air volume.

4 Maximum coverage area.

5 Comfortable and gentle with natural breeze simulation.

5. Six series 7. Ac motor Aerodynamic empennage Six series

It often seen on airplanes and racing cars, but it was not developed for aesthetic: The air will flow in the movement of the blade tip to form a vortex. The installation of a small empennage is designed to eliminate the energy loss, stable fan operation, and bring significant benefits. AireGard HVLS collaborated Germany brand and jointly developed motor. Minimum noise with low gear grinding and grinding process. In addition of strengthen bearing frame Control system structure, trapezoidal shaft structure increased oil seal and strengthened the fuselage structure for the higher safety Electric Schneider set offers built-in factor. security module to cut off the output when accidentally occurs. German brand cabinet, certified by SGS EMC Switzerland, CCC certification and leak test, offers useful shield ability for Airfoil Blades electromagnetic interference. IP55 Protection level and certified by UL, EMC, LVD, and RoHs

Imported high-grade special aviation Chassis magnesium alloy with fluorocarbon paint surface aerodynamic fan blades. The chassis made of 1500T hot satin and AireGard‘s patented fan blade - CNC precision machining process. AireGard Airfoil Blades. Its unique Forging process can ensure the continuity design includes up to three sets of of metal fiber organization. So that the stiffener support system within the forging of the fibrous tissue can maintain blade, enhance fan blade strength, avoid the same shape with complete metal sagging blade and fatigue loss of streamline, to provide the best mechanical connecting components that caused by properties of the site; After CNC the blade. machining, the tolerance of chassis accuracy controlled at 100um, to ensure the precise balance of the site.

9. Six series

SIX series Cooling System Integrated Blower Fan

Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

BLADES SIX-12 SIX-16 SIX-20 SIX-24 DRIVE TRAIN

Blade diameter 12 ft (3.6 m) 16 ft (4.9 m) 20 ft (6.1 m) 24 ft (7.3 m) Gearbox Type GST Series Dual Stage Helical Gearbox

Blade style Airfoil with winglet Manufacturer Lenze Drives GmbH, Germany

Blade material Magnalium (Aluminium Alloy) , Carbon Fluorine Treated Surface Mechanical Efficiency 0.97

Number of blades 6 Max. Torque 375 Nm Standards cURus, GOST-R, CCC & UkrSepro PERFORMANCE & POWER CONTROLS 365,000 CFM 397,000 CFM 428,000 CFM 460,000 CFM Max. Displacement (10,350 CMM) (11,250 CMM) (12,150 CMM) (13,050 CMM) Control Type Variable Frequency Drive ( Inverter Drive )

Variable Speed 90 RPM 70 RPM 60 RPM 50 RPM Features 16-bit Microprocessor Logic , LED Status Display , Built-in Dynamic Braking Transistor Max. Power Usage 1.1 kW 1.5 kW 1.5 kW 1.5 kW Manufacturer Yaskawa Electric Corporation, Japan Equivalent Horsepower Rating 1.5 HP 2.0 HP 2.0 HP 2.0 HP UL 508C , CSA 22.2 No. 14-95 , UL, cUL listed; CE marked , Standards RoHS compliant , EN 50178 (LVD) , EN 50081-2, EN 50082-2 2.4 Amps 3.5 Amps 3.5 Amps 3.5 Amps Rated Current (EMC) , EN 61800-3 , IEC 529, 146 / 415 V / 415 V / 415 V / 415 V Max. Ambient Temperature 50 Celcius WEIGHT & DIMENSIONS for Operation

Total Hanging Weight 65 kg 80 kg 105 kg 120 kg INSTALLATION

MOTOR Mounting Hardware Complete Mounting Kit Included

Motor Type MD Series 3 Phase AC Motor (4 poles) Drop Extensions Optional Extension Lengths Available Manufacturer Lenze Automation GmbH, Germany WARRANTY Max. Ambient Temperature 60 Celcius for Operation WARRANTY 5 Years** Degree of Protection IP55 (EN60529) **Subject to Terms & Conditions.

11. AC MODEL A Six series

SIX-24 24’ (7.3 m)

SIX-20 20’ (6.1 m)

EXTENSION TUBES SIX-16 16’ (4.9 m) min. 300 mm ( 1ft ) SIX-12 12’ (3.6 m)

800 mm

A

Line Drawing control box specifications

General Guideline Before beginning installation, check that the building structure and fan location meet safety guidelines by confirming the below requirements.

Fans mounted on fabricated I-beams, which are common in steel buildings, could cause the 60 65 beam to flex and the fan to move during operation.

The fan’s lateral movement must be secured using guy wires if the fan’s extension tube is 1 ft (0.3 m) or longer or if the mounting structure requires it. If the fan is close to any building

400 2-Ă24 fixtures it is recommended to secure the fan with guy wires as a safety measure. 210

The fan must be installed so that it is ≥ 18 ft (6 m) above the finished floor.

Multiple fans must be spaced at a center-to-center distance that is no less than 2.5x the fan diameter. 210 300 All fan parts must be ≥ 2 ft (0.6m) from all obstructions. The fan installation area must be free of obstructions such as lights, cables, sprinklers, or other building structure components. (mm)

*For specific requirements, please call 1300-88-4273

13. Mounting Details Six series Mounting Details To Conrete Beam Mounting Details To Circular Hollow Section Concrete slab/Beam 4 Nos X M16 X 150 Anchors (Min Grade 30) Circular Hollow M16 Bolts Section & Nuts

Upper yoke Upper Yoke Top View

Drop tube 400 Drop Tube 270 150 Concrete Slab/Beam 97 4 Nos X M16 X 150 Anchors 81 (Min Grade 30) Circular M16 Bolts Hollow & Nuts Section 335

Upper Yoke Upper yoke Drop Tube Front View Drop tube 400 32 170 Mounting Details To Square/Rectangular Hollow Section Mounting Details To I-BEAM 136

Square Hollow Section Beam clamp I-beam Min. 100 mm X 100 mm M16 Bolts Spacer Thickness Min. 4 mm & Nuts Upper yoke M16 bolts Upper Yoke & Nuts Side View

270

Drop tube 170 Drop Tube

195 Square Hollow Section M16 Bolts I-beam M16 bolts Min. 100 mm X 100 mm & Nuts & Nuts Thickness Min. 4 mm Upper yoke (mm) Upper Yoke

Drop Tube Drop tube

15. DC Series

17. BLDC Motor Aerodynamic empennage

BLDC Technology is the cutting-edge technology in the HVLS industry, excellent dynamic characteristics, high efficiency, long lifespan, minimum noise and various speed range. Through years of design and It often seen on airplanes and racing cars, research and development, AireGard has but it was not developed for aesthetic: mastered the most advanced theories and The air will flow in the movement of the techniques of BLDC application in HVLS blade tip to form a vortex. The installation industry and transformed them into of a small empennage is designed to productivity, AireGard has surpassed the eliminate the energy loss, stable fan DC Series performances of all local HVLS products operation, and bring significant benefits. and reaches the advanced world standard.

Airfoil Blades SKF BEarings

Imported high-grade special aviation magnesium alloy with fluorocarbon paint surface aerodynamic fan blades. AireGard‘s patented fan blade - AireGard Airfoil Blades. Its unique design includes up to three sets of stiffener support system within the blade, enhance fan blade strength, avoid With SKF bearings increase, CNC sagging blade and fatigue loss of precision engraving and milling processes connecting components that caused by and high precision engineering to ensure the blade. the stability of the transmission system and longer lifespan.

19.

DC series

Max. Ambient Temperature for 60 Celcius BLADES DC-8 DC-10 DC-12 DC-14 Operation

Blade diameter 8 ft (2.4 m) 10 ft (3.0 m) 12 ft (3.6 m) 14 ft (4.2 m) Degree of Protection IP20

Blade style Airfoil with winglet Cooling System Centrifugal Cooling Blade material Magnalium (Aluminium Alloy) , Carbon Fluorine Treated Surface

Number of blades 8 Sound Level < 43 dB

PERFORMANCE & CONTROLS

POWER DC Series Control Type Variable Frequency Drive ( Inverter Drive ) Max. Displacement 52,618 CFM 84,048 CFM 106,297 CFM 131,723 CFM (1,490 CMM) (2,380 CMM) (3,010 CMM) (3,730 CMM) Features Dual Microprocessor Logic, LED Status Display , Built-in Dynamic Braking Transistor Variable Speed 120 RPM 100 RPM 90 RPM 76 RPM Manufacturer Yaskawa Electric Corporation, Japan Max. Power Usage 150 W 300 W 405 W 410 W UL 508C , CSA 22.2 No. 14-95 , UL, cUL listed; CE marked , Rated Current (Max.) 2.0 Amps / 240 V RoHS compliant , EN 50178 (LVD) , EN 50081-2 , EN 50082- Standards 2(EMC) , EN 954-1 , category 3 safety standard , EN 61800-3 , IEC 529, 146 , FCC CFR 47 Part 15 Subpart B (w/ External Input Voltage 220 - 240 V / 1 P Filter) , TUV Max. Ambient Temperature 50 Celcius WEIGHT & DIMENSIONS for Operation Total Hanging Weight 31 kg 35 kg 38 kg 41 kg INSTALLATION Mounting Hardware Complete Mounting Kit Included MOTOR Drop Extensions Optional Extension Lengths Available Motor Type Brushless DC Motor (BLDC)

Drive Train Gearless Direct Drive WARRANTY Max. Torque 22.5 Nm 32.5 Nm 37.5 Nm 42.5 Nm WARRANTY 3 Years**

Mechanical Efficiency 0.8 **Subject to Terms & Conditions.

21. 82.29 DC MODEL A DC-14 14’ (4.2 m)

DC-12 12’ (3.6 m)

DC-10 10’ (3.0 m) Depend on EXTENSION TUBES the Exntension min. 300 mm ( 1ft ) DC-8 8’ (2.4 m) Tube Length

201.23 DC Series

A Line Drawing

General Guideline Before beginning installation, check that the building structure and fan location meet safety guidelines by confirming the below requirements.

Fans mounted on fabricated I-beams, which are common in steel buildings, could cause the beam to flex and the fan to move during operation.

The fan’s lateral movement must be secured using guy wires if the fan’s extension tube is 1 ft (0.3 m) or longer or if the mounting structure requires it. If the fan is close to any building fixtures it is recommended to secure the fan with guy wires as a safety measure.

The fan must be installed so that it is ≥ 10 ft (3 m) above the finished floor.

Multiple fans must be spaced at a center-to-center distance that is no less than 2.5x the fan diameter.

All fan parts must be ≥ 2 ft (0.6m) from all obstructions. The fan installation area must be free of obstructions such as lights, cables, sprinklers, or other building structure component.

*For specific requirements, please call 1300-88-4273

23. control box specifications Mounting Details

For Rectangular Hollow Section & Circular Hollow Section

80 mm

60 mm 100 mm 4 x M16 Stud & Nuts

Ø 5 mm 285 mm Ø 65 mm 65 mm Rectangular Hollow Scetion Ø 22 mm 65 mm

150 122 x 17 Ø 9 mm 65 mm 63 11

63 DC Series L 56

185 mm 400 140 - 350 122 200

(mm)

195 mm For Concrete Slab 185 mm

40 mm 50 mm 4 x M20 Expansion Bolts 25 mm50 mm 50 mm Ø 130 mm 80 mm 70 mm 130mm 100 mm Ø 5 mm 50 mm 150 Ø 65 mm 60 mm 122 x 17

185 mm 195mm 63 2 x M16 Drop-In Anchors & 11 63 Eys Nuts tied with 56

M5 Stainless Steel Guy Wire 400 140 - 350 122 200

(mm)

25. DCb series 27. DCB Series

Max. Ambient Temperature for 60 Celcius Operation

BLADES DCB-16 DCB-18 DCB-20 DCB-22 Degree of Protection IP20 Blade diameter 16 ft (4.9 m) 18 ft (5.5 m) 20 ft (6.1 m) 22 ft (6.7 m) Cooling System Centrifugal Cooling Blade style Airfoil with winglet

Blade material Magnalium (Aluminium Alloy) , Carbon Fluorine Treated Surface Sound Level 39 dBA 38 dBA 40 dBA 39 dBA

Number of blades 5 CONTROLS DCb series PERFORMANCE & Control Type Variable Frequency Drive ( Inverter Drive ) POWER Features Dual Microprocessor Logic, LED Status Display , Max. Displacement 345,882 CFM 372,352 CFM 412,235 CFM 446,823 CFM Built-in Dynamic Braking Transistor Manufacturer Yaskawa Electric Corporation, Japan Speed 25-100 RPM 25-80 RPM 25-70 RPM 25-60 RPM UL 508C , CSA 22.2 No. 14-95 , UL, cUL listed; CE marked , RoHS Max. Power Usage 600 W 700 W 800 W 900 W compliant , 5.0 Amps 5.5 Amps 6.0 Amps 6.5 Amps Standards EN 50178 (LVD) , EN 50081-2 , EN 50082-2(EMC) , EN 954-1 , Rated Current (Max.) category 3 safety standard , EN 61800-3 , IEC 529, 146 , / 240 V / 240 V / 240 V / 240 V FCC CFR 47 Part 15 Subpart B (w/ External Filter) , TUV Input Voltage 220 - 240 V / 1P Max. Ambient Temperature 50 Celcius WEIGHT & DIMENSIONS for Operation

Total Hanging Weight 64 kg 68 kg 73 kg 78 kg INSTALLATION Mounting Hardware Complete Mounting Kit Included MOTOR Drop Extensions Optional Extension Lengths Available Motor Type Brushless DC Motor ( BLDC ) Drive Train Gearless Direct Drive WARRANTY Max. Torque 210Nm WARRANTY 3 Years** Mechanical Efficiency 0.94 **Subject to Terms & Conditions.

29. DC MODEL A

DCB-22 22’ (6.7 m)

DCB-20 20’ (6.1 m)

EXTENSION TUBES DCB-18 18’ (5.5 m) min. 300 mm ( 1ft ) DCB-16 16’ (4.9 m)

A DCb series

Line Drawing control box specifications

General Guideline Before beginning installation, check that the building structure and fan location meet safety guidelines by confirming the below requirements.

Fans mounted on fabricated I-beams, which are common in steel buildings, could cause the 60 65 beam to flex and the fan to move during operation.

The fan’s lateral movement must be secured using guy wires if the fan’s extension tube is 1 ft (0.3 m) or longer or if the mounting structure requires it. If the fan is close to any building

400 2-Ă24 fixtures it is recommended to secure the fan with guy wires as a safety measure. 210

The fan must be installed so that it is ≥ 18 ft (6 m) above the finished floor.

Multiple fans must be spaced at a center-to-center distance that is no less than 2.5x the fan diameter. 210 300 All fan parts must be ≥ 2 ft (0.6m) from all obstructions. The fan installation area must be free of obstructions such as lights, cables, sprinklers, or other building structure components. (mm)

*For specific requirements, please call 1300-88-4273

31. Mounting Details

Mounting Details To Conrete Beam Mounting Details To Circular Hollow Section Concrete slab/Beam 4 Nos X M16 X 150 Anchors (Min Grade 30) Circular Hollow M16 Bolts Section & Nuts

Upper yoke Upper Yoke Top View

Drop tube 400 Drop Tube 270 150 Concrete Slab/Beam 4 Nos X M16 X 150 Anchors 81 97 (Min Grade 30) Circular M16 Bolts Hollow & Nuts Section 335

Upper Yoke DCB series Upper yoke Drop Tube Front View Drop tube 400 32 170 Mounting Details To Square/Rectangular Hollow Section Mounting Details To I-BEAM 136

Square Hollow Section Beam clamp I-beam Min. 100 mm X 100 mm M16 Bolts Spacer Thickness Min. 4 mm & Nuts Upper yoke M16 bolts Upper Yoke & Nuts Side View

270

Drop tube 170 Drop Tube

Square Hollow Section 195 M16 Bolts I-beam M16 bolts Min. 100 mm X 100 mm & Nuts & Nuts Thickness Min. 4 mm Upper yoke (mm) Upper Yoke

Drop Tube Drop tube

33. PortFolio

DHL , SIX Series One City, USJ SIX Series

From cold rooms to multi-tiered racking, one of their biggest challenge is The economic challenges of operating an al-fresco retail store dictate to maintain a comfortable temperature across their massive warehouse. smart design, value and comfort for customers – as comfortable They chose AireGard as their choice of HVLS fans to move air throughout customers generally shop longer and spend more. AireGard HVLS are the warehouse, from ceiling to floor and wall to wall, including up and over installed in the Garden Boulevards to do just that. obstructions such as racking.

35. PortFolio

MPOB, SIX Series Masjid Sultan Abdul Samad, SIX Series

The client needed air circulation to combat chemical fumes and stay Masjid Sultan Abdul Samad, also fondly known as KLIA Mosque, is a comfortable. They considered installing air conditioning but the high initial distinctive landmark among visitors landing at the KL International cost and prospect of expensive monthly electric bills turned them off. They Airport. With a total ceiling height of more than 50ft, its operator. installed one 24-ft (7.3-m) diameter SIX-24 to move air throughout the Malaysia Airport Holdings Bhd knows there is only one way to keep the entire space. The fan creates a perceived cooling effect that makes main prayer hall cool and comfortable – installing AireGard HVLS fans. occupants feel up to 10°F (5.6°C) cooler.

37. PortFolio

The Gasket Alley, DC Series Pos Malaysia , Shah Alam DC Series Petrol Heads. Custom motorcycles. Groovy folks. Good vibes. The Gasket Alley is a curated space housing all of the above, with a huge Facility managers worked with AireGard to create powerful air movement knack for events from time to time. That’s where they also realised the that kept workers cool in this semi air-conditioned facility. The facility need for cool spaces. They wanted to up the comfort level without installed ten DC-14(4.2-m) fans to help circulate the conditioned air in the compromising their goal of being the greenest auto shop in the business plant to eliminate heat pockets for better comfort and even temperature. and their choice of solution was to install 2 units of our DC-12 (3.6m) diameter HVLS fans. The hot rods couldn’t have been more cooler.

39. PortFolio

Masjid Gulang-Gulang, DC Series Auction Hall, DC Series

A historical mosque located in the small township of Kuala Selangor. Back On a busy afternoon, this auction house would turn into an unpleasant in the days, this was the flagship mosque and the place to go for the place as a result of trapped heat due to poor airflow. The client wanted a muslims prayers. Whilst being small, the akward design of the mosque proper solution, an energy saving one too. We proposed the DC 8 14Ft wasn’t particularly built for having good airflow. So we put up a 12Ft model. It created airflow like never before and at the same time, being HVLS DC FAN and it brought life back into this historical mosque. energy efficient thanks to the DC powered HVLS Fan.

41. PortFolio

Honda Service Centre, Kajang DCB Series SMK St Mary, Kuala Lumpur DCB Series They needed a way to improve the comfort level of the mechanics working For many years, the school officials unsuccessfully tried to cool down the in the service bays, while being operationally efficient and environmentally non-air conditioned multipurpose hall with box fans, floor fans and a variety conscious too. Several different things such as industrial wall fans were of inefficient air movers. Excessive heat made teachers and students tried to bring that heat down and provide comfort but with limited success. uncomfortable at assemblies. With the full support and confidence of the The installation, shipment and delivery of the AireGard HVLS fans met all board of governors, the school chose AireGard HVLS fan as their choice the owner’s expectations, and the fan's performance has drawn rave over other major competitors simply because of our expertise and good reviews. consultation services.

43. PortFolio

Amway, Petaling Jaya DCB Series IOI Mall, DCB Series

Set to undergo a major and important facelift in the near future, the mall AireGard's quiet and effective gearless and silent HVLS fans was brought management decided that taking care and making sure their customers in to relieve the stagnant air by improving air circulation in the sorting are comfortable now is as important. AireGard was chosen because of and unloading area - where most of their employees are. their confidence in our credibility to deliver.

45. Gard squard

Our trained engineers will visit your site to At AireGard, we set ourselves apart from the evaluate the situation competition by providing professional installation, SITE EVALUATION excellent customer service and prompt after-sales services. Our promise is only possible simply because of Gard Squad, our in-house technical team. Valuable info collected from site visit will be Specially factory-trained and certified, Gard Squad important for our team to design an action plan team takes the guess work out of any problems or for your site. DESIGN service call and in reliably quick time.

We will present the proposal to you and explain thoroughly on what should you install and why.

PROPOSAL

47.