Data Center Information Guide
Total Page:16
File Type:pdf, Size:1020Kb
DATA CENTER INFORMATION GUIDE CheyenneCheyenne Data Data Center Center • • 1 1 With data center facilities and cloud installations across the country, Green House Data provides cloud hosting, colocation, disaster recovery, and managed IT services throughout North America. Companies of all industries and sizes, including healthcare, legal, MSPs, energy, and retail, choose Green House Data for custom infrastructure design and Hear from a Human Support. The company is a certified Microsoft Partner, VMware provider, SOC 1 and 2 Type II and HIPAA com- pliant, as well as a B-Corp and EPA Green Power Partner. 2 • Cheyenne Data Center OUR HOUSE, YOUR HOUSE With data centers across the United States, Green House Data is uniquely positioned to offer energy-efficient, highly reliable IT infrastructure hosting and related services. Explore the connectivity, resiliency, and design of each of our facilities. CONTENTS Cheyenne, Wyoming ......................... 4 Seattle, Washington ........................... 6 Bellingham, Washington ................... 8 Atlanta, Georgia ................................ 10 Optional Services ............................. 12 Dedicated Support ........................... 13 Nationwide Cloud ............................. 14 Cheyenne Data Center • 3 CHEYENNE WYOMING Space & Power Square Footage: 45,000 Provisioned UPS Power: 5,000 kW (5 MW) Potential UPS Power: 8,000 kW (8 MW) Year Built: 2014 Full Cabinet Size: 24” W x 47” D x 84” H Power per Cabinet: Up to 15 kW Connectivity Available Carriers: CenturyLink, Level 3, Zayo, Charter Speeds: Up to 100 Gbps Points of Entry: Four Meet-Me-Room / Peering Exchange Access: Yes Features • Outside 100 year floodplain • Purpose-built data center • Slab floor • Hardened exterior able to withstand 125+ MPH winds • Onsite NOC staffed 24/7 • Customer portal for ticketing, work notifications, and access control Security • 24/7/365 onsite security personnel and CCTV monitoring • Mantrap access to white space • Biometric and key card access controls • Ballistic rated exterior walls • Pre-action fire suppression • Low risk of natural disasters 4 • Cheyenne Data Center Data Center Infrastructure Concurrently Maintainable Electric: Yes Concurrently Maintainable Mechanical: Yes Incoming Electrical Voltage: 13.2 kV Incoming Electrical Service Type: Ring Bus Electrical Design: Distributed Redundant Power Circuits: 208V, 208 three phase, 120V UPS Redundancy: N+1 (2N to cabinet) UPS Type: Static UPS: PDU Redundancy: N+1 (2N to cabinet) Static Switch PDUs: Yes Generator Redundancy: N+1 Diesel Fuel Runtime at 100% Load: 24 hours with three resupply contracts in place Fire Suppression: VESDA and pre-action systems Primary Cooling Type: Indirect Evaporative Free Cooling Cooling Redundancy: N+1 Cooling Tower Redundancy: N/A Chiller Redundancy: N/A Variable Frequency Drives: Yes PUE: 1.14 Energy Efficient Design: Hot aisle containment, free cooling, energy consumption offset by Renewable Energy Credits Compliance & Certifications • HIPAA Compliant • SSAE 18 Type II Compliant • (includes SOC 1 and SOC 2) • PCI DSS 2.0 Compliance Available • Can assist with SOX, GLB, and other standards Building Amenities • Dedicated office space • 24/7/365 onsite security personnel and CCTV monitoring • Shared office areas • Mantrap access to white space • Shared / reservable conference rooms • Biometric and key card access controls • Private / shared staging • Ballistic rated exterior walls • Secure storage areas • Pre-action fire suppression • Kitchen • Low risk of natural disasters • Lounge • Showers Cheyenne Data Center • 5 SEATTLE WASHINGTON Space & Power Square Footage: 8,550 Provisioned UPS Power: 700 kW Potential UPS Power: 1 MW (1,000 kW) Year Built: 1981 - renovated several times Full Cabinet Size: 24” W x 40” or 48” D x 84” H Power per Cabinet: 1.92 kW up to 10 kW Connectivity Available Carriers: Over 100 providers plus the Seattle Internet Exchange Speeds: Up to 100 Gbps Meet-Me-Room / Peering Exchange Access: Yes Features • Outside 100 year floodplain • Raised floor • Onsite NOC • Customer portal for ticketing, work notifications, and access control • Same-floor access to meet-me-room Security • 24/7/365 onsite security personnel and CCTV monitoring • Biometric and key card access controls • Mantrap access to building • Pre-action fire suppression 6 • Seattle Data Center Data Center Infrastructure Concurrently Maintainable Electric: Yes Concurrently Maintainable Mechanical: Yes Incoming Electrical Voltage: 13.2 kV Incoming Electrical Service Type: Dual Circuits Electrical Design: Distributed Redundant - DC Power 100A to 500A; 205 to 300 kVA IT Load; 600 or 800A Utility Load UPS Redundancy: N+1 UPS Type: Static UPS PDU Redundancy: N+1 Generator Redundancy: N+1 Diesel Fuel Runtime at 100% Load: 24 hours with resupply contracts in place Fire Suppression: Wet Pipe and pre-action available Primary Cooling Type: Air-cooled chillers CRAH/CRAC Redundancy: N+1 Cooling Tower Redundancy: N+1 Chiller Redundancy: N+1 PUE: 1.5 Energy Efficient Design: Hot aisle containment, energy consumption offset by Renewable Energy Credits Compliance & Certifications • HIPAA Compliant • SSAE 18 Type II Compliant • (includes SOC 1 and SOC 2) • PCI DSS 2.0 Compliance Available • Can assist with SOX, GLB, and other standards Building Amenities • 24/7/365 onsite security personnel and CCTV monitoring • Shared office areas • Biometric and key card access controls • Shared / reservable conference rooms • Mantrap access to building • Shared staging • Pre-action fire suppression • Secure storage areas • Kitchen Seattle Data Center • 7 BELLINGHAM WASHINGTON Space & Power Square footage: 8,010 Provisioned UPS Power: 350 kW Potential UPS Power: 400 kW Year Built: 1999 Full Cabinet Size: 24” W x 39” D x 84” H Power per Cabinet: 1.92 kW up to 10kW Connectivity Available Carriers: Wave Broadband, Zayo Level 3 and 100s of SIX providers via crossconnect to WBX Speeds: Up to 10 Gbps Meet-Me-Room / Peering Exchange Access: Yes Features • Outside 100 year floodplain • Raised floor • Onsite NOC • Customer portal for ticketing, work notifications, and access control • Dark fiber to Westin Building Exchange Security • 24/7/265 onsite security personnel and CCTV monitoring • Biometric and key card access controls • Mantrap access to white space • Pre-action and FM 200 fire suppression 8 • Bellingham Data Center Data Center Infrastructure Concurrently Maintainable Electric: Yes Concurrently Maintainable Mechanical: Yes Incoming Electrical Voltage: 13.2 kV Incoming Electrical Service Type: Dual Circuits Electrical Design: Distributed Redundant - 800A Utility Load, 430 kVA IT Load UPS Redundancy: N+1 UPS Type: Static UPS 8,010 PDU Redundancy: N+1 350 kW Generator Redundancy: N+1 400 kW Diesel Fuel Runtime at 100% Load: 24 hours with resupply contracts in place 1999 Fire Suppression: Pre-action and FM 200 24” W x 39” D x 84” H Primary Cooling Type: Air-Cooled chillers 1.92 kW up to 10kW CRAH/CRAC Redundancy: N+1 Cooling Tower Redundancy: N Chiller Redundancy: N+1 PUE 1.8 Energy Efficient Design: Energy consumption offset by Renewable Energy Credits Compliance & Certifications • HIPAA compliant • SSAE 18 Type II compliant • (includes SOC 1 and SOC 2) • PCI DSS 2.0 compliance available • Can assist with SOX, GLB, and other standards Building Amenities • Shared office areas • Shared / reservable conference rooms • 24/7/265 onsite security personnel and CCTV monitoring • Shared staging • Biometric and key card access controls • Secure storage areas • Mantrap access to white space • Kitchen • Pre-action and FM 200 fire suppression Bellingham Data Center • 9 Green House Data colocation services ATLANTA in Atlanta are provided from rack space GEORGIA within Equinix AT1 and AT3 facilities. Space & Power Square footage: 70,390 (AT1 + At3) Provisioned UPS Power: 140 kW Potential UPS Power: 140 kW Electrical Tier Equivalent: Tier 3 Mechanical Tier Equivalent: Tier 3 Year Built: 1927 - renovated 2000 Connectivity Available Carriers: Over 180 carriers including Equinix Cloud Connect, Internap, AT&T, Verizon, Cogent, Megapath, Masergy, TW Telecom, FiberLight Speeds: Up to 100 Gbps Meet-Me-Room / Peering Exchange Access: Yes Features • Raised floor • Onsite NOC staffed 24/7 • Customer portal for ticketing, work notifications, and access control Security • 24/7/265 onsite security personnel and CCTV monitoring • Biometric and key card access controls • Mantrap access to white space • Pre-action fire suppression 10 • Atlanta Data Center Data Center Infrastructure Concurrently Maintainable Electric: Yes Concurrently Maintainable Mechanical: Yes Incoming Electrical Voltage: 13.2 kV Incoming Electrical Service Type: Dual Circuits Electrical Distribution Design: Distributed Redundant UPS Redundancy: N+1 UPS Type: Static UPS PDU Redundancy: N+1 70,390 (AT1 + At3) Generator Redundancy: N+1 140 kW Diesel Fuel Runtime at 100% Load: 24 hours with resupply contracts in place 140 kW Primary Cooling Type: Direct Evaporative Tier 3 CRAH/CRAC Redundancy: N+1 Tier 3 Cooling Tower Redundancy: N+1 1927 - renovated 2000 Chiller Redundancy: N+2 PUE 1.5 Energy Efficient Design: Energy consumption offset by Renewable Energy Credits Compliance & Certifications • HIPAA compliant • SSAE 18 Type II compliant • (includes SOC 1 and SOC 2) • PCI DSS 2.0 compliance available • ISO 27001 • Can assist with SOX, GLB, and other standards • LEED Silver Building Amenities • Break room • Shared office areas • 24/7/265 onsite security personnel and CCTV monitoring • Shared / reservable conference