Alitherm 600 double glazed aluminium framed manufactured by Smart Systems (RAL 7039). Windows to achieve u-value of 1.3 External reveals and W/M2K in accordance with manufacturers heads to rainscreen cladding specifications. Details as per the schedule of system to be constructed from works and window schedule 12423.007 3mm powder coated aluminium Remove, sheet (RAL 7039) and fixed in ArGeTon cladding panels of 1000mm x 300mm x35mm depth fixed on amend and aluminium horizontal support rails with anodised aluminium tile clips in accordance with Taylor Maxwell reinstate

accordance with manufacturers specification. Panels to be 'Ferro Grey'. 12423.009 Elevation C drawings ARG-CDO7, existing CCTV Remove, ARG-CD08 and ARG-CD09. equipment amend and reinstate existing CCTV DWG No. equipment Notes: N

Retain existing Remove, finish to amend and vehicular dock reinstate existing palisade fencing A

B D1

Burnley Combined Court Existing uPVC downpipe to be removed and Allow to amend D replaced with new Existing palisade Existing structural Install Cedral weatherboard 'Click' cladding panels of Existing and roller and redecorate Kingspan Highline fencing and roller to be clad with Alumasc 186mm width to underside of the existing in shutters to be removed, Continue existing timber aluminium system. Cut and amend shutters to be accordance with manufacturers recommendations. Rendabrick to all faces. Cut and amend C Continue amended and reinstated Alumasc louvred vents Allow to amend Allow for all existing palisade removed, amended Cladding colour to be dark grey (CC15) and fixed to Insulate front face only to existing palisade Alumasc to suit reduced opening Rendabrick to with 2no. coats and redecorate Terminate system in accordance amendments to suit fencing and and reinstated to 70mm x 38mm treated timber softwood battens with provide a consistent fencing and with manufacturers instructions a Existing uPVC Supply and install new Alumasc Rendabrick to extend 300mm external grade existing timber B1 new line. sandstone dwarf suit reduced stainless steel click screws. Battens are to be building line. Termination sandstone dwarf minimum of 150mm from existing downpipe to be Cut and amend Rendabrick Lite External extend 300mm into reveal black paint louvred vents with wall to suit new opening mechanically fixed to existing substrate at a maximum detail as per Alumasc wall to suit new gas supply pipework. Install removed and existing stonework Insulated Render System in into reveal 2no. coats external building line of 600mm centres. drawing ref S-SUPA-M-201 building line 18mm marine plywood to face up replaced with new kerb to suit new accordance with manufacturers grade black paint remaining visible tiles and Kingspan Highline building line recommendations and (RAL 9005) decorate with 2no. coats external aluminium system. specification grade black paint. Terminate Allow for all Undercroft Car Park 150mm from F.F.L amendments to suit new building line.

Supply and install new Alitherm 600 double glazed aluminium framed ArGeTon cladding panels of 1000mm x Alumasc Rendabrick Lite windows manufactured by Smart Systems Interface between Rendabrick Lite and Kingspan 300mm x35mm depth fixed on aluminium Elevation D1 External Wall Insulated (RAL 7039). Windows to achieve u-value of Highline aluminium gutter to be in accordance with Remove, horizontal support rails with anodised Render System in accordance 1.3 W/M2K in accordance with manufacturers Alumasc 'EWI Gutter Detail' drawing S-SUPA-M-703 amend and aluminium tile clips in accordance with with manufacturers specifications. Details as per the schedule of reinstate manufacturers specification. Panels to be recommendations and works and window schedule 12423.007 existing CCTV specification equipment 'Ferro Grey'.

Vehicle Dock

Allow to terminate Existing security fence to be removed Provide and install 'party wall stop system a miniumum of and replaced with new PPC finish bead detail' in accordance with Provide and install 'party wall stop Terminate system here by use of a 150mm above the palisade fencing to fit new building line Alumasc drawing S-SUPA-M-401 to bead detail' in accordance with Existing external lights to be bellcast bead Insulated render system to be terminated existing external following the installation of the terminate the system flush with the Alumasc drawing S-SUPA-M-401 to removed and reinstates upon with bellcast bead a minimum of 150mm level as per alumasc insulated render system. Allow for front elevation of the vehicular dock. terminate the system 25mm from completion. Allow for electrical above existing adjacent flat level. Allow drawing S-SUPA-M-201 secure mechanical fixings to wall using Supply and install proprietary uPVC the rear elevation of the vehicular amendments as necessary. stainless steel anti-tamper mechanical blanking plate and securely fix into to form 25mm chase into substrate and dock. fixings. Railings to be removed and existing substrate with stainless steel install new code 4 lead flashing to junction replaced in the same shift to ensure brackets and M8 masonry anchors at a between court building and flat roof. Apply Existing timber set to be security levels are maintained. Existing maximum of 500mm centres to 2no. coats anti-vandal paint to all new lead removed and replaced by new to be retained. completely cover the junction between work. Refer to Aluasc roof abutment detail Comar 7Pi aluminium door set. the court building and vehicle dock drawing S-SUPA-M-808 for further Refer to schedule of works for information further details.

%QR[TKIJV#NNTKIJVUTGUGTXGF6JKUFTCYKPIOWUVPQVDGTGRTQFWEGFYKVJQWV RGTOKUUKQPHTQO##2TQLGEVU.VF&QPQVUECNGQHHVJKUFTCYKPI#NN FKOGPUKQPUCTGVQDGEJGEMGFQPUKVGD[EQPVTCEVQTUWDEQPVTCEVQT#P[ FKUETGRCPEKGUVQDGTGRQTVGFVQ##2TQLGEVU.VF

Rev Date Revision notes By Check

1 Pilkington Court Sinclair Way Prescot Business Park, Prescot Liverpool L34 1QG Tel: 0151 430 2340 Fax: 0151 430 2341

Additional offices in Birmingham, Leeds, , Manchester and Newcastle www.aaprojects.co.uk

Client Drawing Title G4S Proposed Elevation Plans (Elevations C and D1)

Project Title Drawn Date Burnley Combined Court JM 05/2018

Re-Cladding Works Checked Date TH 05/2018

A1 DWG No. 12423.009 Scale 1:100 Revision