ENERGY STAR Lamps V1.0 Draft 4 Comments” in the Subject Line

Total Page:16

File Type:pdf, Size:1020Kb

ENERGY STAR Lamps V1.0 Draft 4 Comments” in the Subject Line ENERGY STAR® Program Requirements Product Specification for Lamps (Light Bulbs) Eligibility Criteria Version 1.0, DRAFT 4 Following is the fourth draft of Version 1.0 ENERGY STAR Product Specification for Lamps. A product shall meet all of the identified criteria if it is to earn the ENERGY STAR. Note: Partners are strongly encouraged to read the cover letter distributed with this draft, and all note boxes located throughout this draft to learn about the changes proposed. For purposes of this specification development process, EPA invites stakeholders to send comments to [email protected], with “ENERGY STAR Lamps V1.0 Draft 4 Comments” in the subject line. 1. SPECIFICATION SCOPE & LAMP CLASSIFICATION 1.1. Included Products The ENERGY STAR Lamps specification (“this specification”) scope includes the lamp types intended to replace incandescent lamps as outlined in Table 1. The scope is limited to lamps with integrated ballasts and drivers intended to be connected to the electric power grid with the following ANSI standard base types: E26, E26d, E17, E11, E12, GU24, GU5.3, and GX5.3. The scope is also limited to lamps with rated nominal operating voltages of 120, 240 or 277 VAC, or 12 or 24 VAC or VDC. Table 1: Specification Scope and Classification Lamp Purpose and ANSI Standard Lamp Non-Standard Lamp Form Factor Performance Description Shape 1 Omnidirectional – A, BT, P, PS, S and T Self-ballasted compact fluorescent lamps (CFLs) intended to Lamps intended for general replace ANSI standard incandescent lamps that do not meet purpose that meet applicable Lamp Shape Dimension requirements. omnidirectional performance requirements in this The following self-ballasted compact fluorescent lamps are specification. included: Decorative - Lamps of B, BA, C, CA, DC, F, G Bare spiral common decorative shapes Bare mini-spiral meeting applicable decorative Bare twin tube performance requirements in Bare triple tube this specification. Bare quadruple tube Directional - Lamps meeting R, BR, ER, MR and PAR Covered CFLs applicable directional Covered CFLs with reflectors performance requirements in this specification. 1 Standard form factor lamps must meet the ANSI standard lamp type dimensional requirements in the specification and may claim wattage and ANSI lamp type equivalency. All solid-state lamps must meet standard lamp dimensional requirements. ENERGY STAR Program Requirements for Lamps - Eligibility Criteria Page 1 of 30 1.2. Excluded Products: Lamps, other than MR types, that operate only on an external (i.e. not integral to the lamp) ballast, driver or transformer, e.g. pin-based fluorescent lamps (linear and compact) or their solid-state replacements. Solid-state lamps intended to replace linear fluorescent or high-intensity discharge lamps. Lamps powered by an internal power source, e.g. solar-powered cell. Lamps incorporating power-consuming features in the on or off state which do not provide illumination (e.g. audio functions, air fresheners). Lamp technologies lacking applicable industry standardized methods of measurement. Lamps with bases not covered in ANSI standards. Zhaga compliant LED light engines. Note: In this Draft 4, EPA has removed the GU-10 base from Section 1.1. Included Products to avoid confusion regarding the eligibility of line voltage MR-16 products with GU-10 bases that will not be covered by the program until maximum and minimum overall lengths (MOL) are established by ANSI. This base and product type combination is now listed in Section 3.1.7 Consideration for Future Revisions. In Section 1.2 Excluded Products the bullet for “Solid-state lighting lamps with non-standard form factors” was removed to avoid confusion over lamps that do not follow ANSI outlines but fit within the MOL and MOD of the ANSI shape per Lamp Shape Dimensions requirements in this specification. The second footnote included under Table 1 as presented in Draft 3 was also removed to avoid limitations on educating consumers about the means in which they can find efficient replacement bulbs. It remains EPA’s intent to provide consumers with efficient replacement products without sacrifice to performance and not award the ENERGY STAR label to products that look like common incandescent lamps but fail to deliver the necessary light distribution to properly replace currently installed products. 2. EFFECTIVE DATE The ENERGY STAR Lamps Version 1.0 specification shall take effect TBD. To qualify for ENERGY STAR, a product model shall meet the ENERGY STAR specification in effect on its date of manufacture. The date of manufacture is specific to each unit and is the exact date on which a unit is considered to be completely assembled. Note: Lamps Version 1.0 is set to take effect 12 months after the release of the Final Program Requirements. This time will allow manufacturers with qualified products under the existing ENERGY STAR Compact Fluorescent Lamps V4.3 and Integral LED Lamps Version 1.4 specifications sufficient time to transition to the new specification. Manufacturers are encouraged to begin testing and certifying products to this specification as soon as it is final. EPA recognized certification bodies will be asked to stop certifying products to the ENERGY STAR Compact Fluorescent Lamps V4.3 and Integral LED Lamps V1.4 specifications nine months after the release of the final Lamps V1.0 specification. This transition period allows products in testing for the existing specifications to complete and be certified to the specification they were designed to. As of the Version 1.0 effective date, only those products that have been certified to the new requirements will appear on the Qualified Product List 3. FUTURE SPECIFICATION REVISIONS EPA reserves the right to change this specification should technological and/or market changes affect its usefulness to consumers, industry, or the environment. In keeping with current policy, revisions to the specification are arrived at through stakeholder discussions. In the event of a specification revision, please note that ENERGY STAR certification is not automatically granted for the life of a product model. While this document currently refers to industry standards and test procedures for fluorescent and solid-state lighting sources, as new technologies emerge that have equal or better performance to the levels proposed here, consistent with a technology neutral approach, EPA may amend the program requirements by adding additional requirements, methods of measurement and reference documents. ENERGY STAR Program Requirements for Lamps - Eligibility Criteria Page 2 of 30 3.1. Considerations for Future Revisions 3.1.1. Lamps incorporating power-consuming features when off e.g. Wi-Fi. EPA is committed to continuing to develop performance levels for lamps that account for special features and functionality that benefit consumers, and anticipates that lamps with new features may become more prevalent in the coming years as technology advances, particularly with solid-state lamps. EPA is interested in better understanding the power consumption associated with these products and will work with stakeholders to monitor the growth of lamps with power-consuming features in the off state for additional consumer benefit. EPA will explore the possibility of expanding the scope of this specification to include these products with appropriate off-state power consumption requirements in a future revision. 3.1.2. Directional lamp beam quality EPA will continue to monitor the market and work with stakeholders to explore methods for evaluating beam performance to avoid consumer dissatisfaction with ENERGY STAR certified lamps. To support this effort EPA will be collecting luminous distributions test data for all directional lamps. 3.1.3. Enhanced requirements for dimmable lamps EPA is committed to continuing to develop performance requirements for lamps that incorporate special features and functionality that benefit consumers such as dimming. Basic dimming requirements are included in this specification as a first step to address the most common types of dimmable lamps currently in the market. EPA will continue to explore opportunities to improve the dimming experience and accurately capture the performance of dimmable lamps. For example, EPA understands that useful life of dimmable products may be significantly reduced or extended for some products when they are operated in a dimmed state. EPA hopes to better understand the actual use of dimmable products in the field to examine expanding requirements for dimmable lamps. 3.1.4. Color As indicated in previous drafts of this specification, EPA sees color quality as an important aspect and a potential barrier to broader consumer adoption of energy efficient lighting. EPA will continue to monitor the market and explore opportunities for improving color quality and consistency of lamps to appropriately address this barrier while balancing other considerations such as cost, efficacy and other performance trade-offs. 3.1.5. Zhaga compliant LED light engines EPA will continue to monitor the development and proliferation of these products. 3.1.6. Industry test methods in development EPA and DOE actively monitor the activities of lighting standards working groups and regulatory activities that may impact ENERGY STAR specifications. Several relevant test methods and technical memoranda are in development, such as LM-84 and TM-28 for testing and projecting lumen maintenance for solid-state lighting end products, which the EPA and DOE will evaluate when
Recommended publications
  • ENERGY STAR Lamps V2.0 Revised Spec
    ENERGY STAR® Program Requirements Product Specification for Lamps (Light Bulbs) Eligibility Criteria Version 2.0 Following is the Version 2.0 product specification for ENERGY STAR certified Lamps. A product shall meet all of the identified criteria if it is to earn the ENERGY STAR. To certify a lamp for ENERGY STAR, first determine which requirements in this document are applicable to the specific lamp. ENERGY STAR requirements are specific to lamps classified by the program as omnidirectional, directional, or decorative. This specification is generally organized by the requirements, not by lamp type or by light source technology. Partners are advised to review each section, and take note of exceptions where specific performance criteria need not be evaluated. 1. SPECIFICATION SCOPE & LAMP CLASSIFICATION 1.1. Included Products The ENERGY STAR Lamps specification (“this specification”) scope includes the lamp types intended to replace incandescent lamps as outlined in Table 1. The scope of this specification is limited to lamps with: Integrated ballasts and drivers intended to be connected to the electric power grid with the following ANSI standard base types: E26, E26d, E17, E11, E12, G4, G9, GU10, GU24, GU5.3, and GX5.3; and Rated nominal operating voltages of 120, 240 or 277 VAC, or 12 or 24 VAC or VDC. Table 1: Specification Scope and Classification Lamp Purpose and ANSI Standard Non-Standard Lamp Form Factor Performance Description Lamp Shape1 Omnidirectional – Self-ballasted compact fluorescent lamps (CFLs) intended to replace ANSI Lamps intended for general standard incandescent lamps that do not meet Lamp Shape Dimension purpose that meet applicable A, BT, P, PS, S and T requirements.
    [Show full text]
  • What Is ENERGY STAR?
    What is ENERGY STAR? • ENERGY STAR is a U.S. voluntary program that helps businesses and individuals save money and protect our climate through superior energy efficiency. 1 Who manages ENERGY STAR? • The U.S. Environmental Protection Agency manages the Energy Star program. • The U.S. Department of Energy develops energy test procedures for products covered by Energy Star and conducts product compliance testing. 2 How did ENERGY STAR start? • In 1992, the US Environmental Protection Agency (EPA) introduced ENERGY STAR as a voluntary labeling program designed to identify and promote energy- efficient products to reduce greenhouse gas emissions. • Computers and monitors were the first labeled products. • Through 1995, EPA expanded the label to additional office equipment products and residential heating and cooling equipment. • In 1996, EPA partnered with the US Department of Energy to cover more product categories. 3 What does ENERGY STAR cover? • The ENERGY STAR label is now on major appliances, office equipment, lighting, home electronics, new homes and commercial and industrial buildings and manufacturing plants. 4 What has ENERGY STAR Accomplished? • Through its partnerships with 18,000 private and public sector organizations, has successfully delivered energy and cost savings across the country, saving businesses, organizations, and consumers $24 billion in 2012 alone. • Over the past two decades, ENERGY STAR has been a driving force behind the more widespread use of such technological innovations as efficient fluorescent lighting, power management systems for office equipment, and low standby energy use. 5 Greenhouse Gas Savings Over Time 6 How does it work? -Products • EPA evaluates products sold in the US market.
    [Show full text]
  • ENERGY STAR Program Requirements for Computers
    ® ENERGY STAR Program Requirements for Computers Partner Commitments Following are the terms of the ENERGY STAR Partnership Agreement as it pertains to the manufacture and labeling of ENERGY STAR qualified products. The ENERGY STAR Partner must adhere to the following partner commitments: Qualifying Products 1. Comply with current ENERGY STAR Eligibility Criteria, which define performance requirements and test procedures for Computers. A list of eligible products and their corresponding Eligibility Criteria can be found at www.energystar.gov/specifications. 2. Prior to associating the ENERGY STAR name or mark with any product, obtain written certification of ENERGY STAR qualification from a Certification Body recognized by EPA for Computers. As part of this certification process, products must be tested in a laboratory recognized by EPA to perform Computer testing. A list of EPA-recognized laboratories and certification bodies can be found at www.energystar.gov/testingandverification. Using the ENERGY STAR Name and Marks 3. Comply with current ENERGY STAR Identity Guidelines, which define how the ENERGY STAR name and marks may be used. Partner is responsible for adhering to these guidelines and ensuring that its authorized representatives, such as advertising agencies, dealers, and distributors, are also in compliance. The ENERGY STAR Identity Guidelines are available at www.energystar.gov/logouse. 4. Use the ENERGY STAR name and marks only in association with qualified products. Partner may not refer to itself as an ENERGY STAR Partner unless at least one product is qualified and offered for sale in the U.S and/or ENERGY STAR partner countries. 5. Provide clear and consistent labeling of ENERGY STAR qualified Computers.
    [Show full text]
  • Energy Policy Act of 2005
    PUBLIC LAW 109–58—AUG. 8, 2005 ENERGY POLICY ACT OF 2005 VerDate 14-DEC-2004 09:45 Sep 08, 2005 Jkt 039139 PO 00058 Frm 00001 Fmt 6579 Sfmt 6579 E:\PUBLAW\PUBL058.109 APPS10 PsN: PUBL058 119 STAT. 594 PUBLIC LAW 109–58—AUG. 8, 2005 Public Law 109–58 109th Congress An Act Aug. 8, 2005 To ensure jobs for our future with secure, affordable, and reliable energy. [H.R. 6] Be it enacted by the Senate and House of Representatives of Energy Policy Act the United States of America in Congress assembled, of 2005. 42 USC 15801 SECTION 1. SHORT TITLE; TABLE OF CONTENTS. note. (a) SHORT TITLE.—This Act may be cited as the ‘‘Energy Policy Act of 2005’’. (b) TABLE OF CONTENTS.—The table of contents for this Act is as follows: Sec. 1. Short title; table of contents. TITLE I—ENERGY EFFICIENCY Subtitle A—Federal Programs Sec. 101. Energy and water saving measures in congressional buildings. Sec. 102. Energy management requirements. Sec. 103. Energy use measurement and accountability. Sec. 104. Procurement of energy efficient products. Sec. 105. Energy savings performance contracts. Sec. 106. Voluntary commitments to reduce industrial energy intensity. Sec. 107. Advanced Building Efficiency Testbed. Sec. 108. Increased use of recovered mineral component in federally funded projects involving procurement of cement or concrete. Sec. 109. Federal building performance standards. Sec. 110. Daylight savings. Sec. 111. Enhancing energy efficiency in management of Federal lands. Subtitle B—Energy Assistance and State Programs Sec. 121. Low-income home energy assistance program. Sec. 122. Weatherization assistance.
    [Show full text]
  • Climate Change Mitigation: EPA's Role in President Obama's Action
    CLIMATE CHANGE MITIGATION EPA’S ROLE IN PRESIDENT OBAMA’S ACTION PLAN Sally Rand Office of Air and Radiation May 7, 2014 PRESIDENT OBAMA’S CLIMATE ACTION PLAN • Calls on the federal government to work together with states, tribes, cities, industries, consumers and the international community to address one of the greatest challenges of our time. • Reinforces the federal commitment to: – Cutting harmful pollution, – Protecting our country from the impacts of climate change, and – Leading an international effort to address a changing climate. 2 EPA MITIGATION ACTIONS UNDER PRESIDENT OBAMA’S PLAN • Reducing carbon pollution from power plants • Building a 21st century transportation sector • Cutting energy waste in homes, businesses, and factories • Reducing methane and HFCs • Advance public-private partnerships • Leading international efforts to address global climate change 3 4 CARBON STANDARDS FOR NEW POWER PLANTS • Standards for new power plants under 111(b) – Proposal issued on September 20, 2013, published January 8, 2014 • Follows usual approach to setting New Source Performance Standards • Reflects more than 2.5 million public comments on a 2012 proposal and recent trends in the electric power sector • Sets separate standards for different types of new power plants – Defines Best System of Emission Reduction that is based on adequately demonstrated technologies – Public comment period closes on May 9, 2014 5 CARBON GUIDELINES FOR EXISTING POWER PLANTS • Guidelines for existing power plants under 111(d) – Will follow EPA’s normal, open and transparent regulatory process • Proposal: June 2014—Currently at OMB for interagency review • Final: June 2015 • State 111(d) Plans: June 2016 – Existing power plants are different than new power plants • Guidelines are expected to be different from, and less stringent than, the proposed standards for new plants.
    [Show full text]
  • ENERGY STAR® and Other Climate Protection Partnerships 2010 Annual Report ENERGY STAR® and OTHER CLIMATE PROTECTION PARTNERSHIPS 2010 ANNUAL REPORT
    ENERGY STAR® and Other Climate Protection Partnerships 2010 Annual Report ENERGY STAR® AND OTHER CLIMATE PROTECTION PARTNERSHIPS 2010 ANNUAL REPORT CONTENTS Letter from the Administrator .............................................................................................................................................................................1 Executive Summary ..............................................................................................................................................................................................2 Highlights of 2010 .........................................................................................................................................................................................4 ENERGY STAR Overview ......................................................................................................................................................................................8 ENERGY STAR Qualified Products ....................................................................................................................................................................13 ENERGY STAR in the Residential Sector .........................................................................................................................................................19 ENERGY STAR in the Commercial Sector .......................................................................................................................................................23
    [Show full text]
  • The ENERGY STAR Office Equipment Example
    Market Transformation Through International Cooperation: The ENERGY STAR@ Office Equipment Example Scott Thigpen, Andrew Fanara, Alison ten Cate, EPA, Washington, DC Paolo Bertoldi, European Commission Energy Directorate, Brussels Toshimi Takigawa, Ministry of International Trade and Industry, Tokyo ABSTRACT Though most market transformation efforts take place at the national or even local level, this paper, using the example of the ENERGY STAR@Office Equipment Program, illustrates the possibilities of international cooperation for achieving larger scale transformations. Specifically, potential benefits include complete and global market transformation, production efficiencies, and reduction of potential barriers to trade, as well as administrative efllciencies in managing programs. To achieve these efficiencies, managers of market transformation efforts must overcome significant challenges such as dealing with multiple languages and cultures, differing power conditions and energy prices, and competing policy priorities. While these issues can be managed, it is also challenging to set programs’ efficiency levels. The paper reviews these challenges and benefits, citing the case of the ENERGYSTARinternational collaboration on office equipment, offering two years of experience between the U.S. and Japan, and anticipating Europe’s entry into the program. Introduction The ENERGY STAR programs were introduced in 1993 as part of President Clinton’s Climate Change Action Plan. This plan was based on the premise that greenhouse gas emissions in the United States could be significantly reduced through voluntary efforts. As noted in the Climate Action Report, the purpose of the program is to “bring high-efficiency consumer products into America households and buildings..., including those for space heating and cooling, water heating, lighting, refrigeration laundering, cooking and other services” (CAR 1997).
    [Show full text]
  • Energy Star Faq Wp
    Insightful ENERGY STAR ® FAQs for Staying Ahead of the Game Intertek Testing Services 70 Codman Hill Road Boxborough, MA 01719 www.intertek.com 1-800-WORLD LAB [email protected] Insightful ENERGY STAR ® FAQs for Staying Ahead of the Game Contents Introduction .....................................................................................................3 About EPA’s ENERGY STAR Program..................................................................3 Momentum Achieved.................................................................................. 3 Cause and Effect......................................................................................... 4 Qualification Procedures Changes..................................................................... 5 Certification Body Approval......................................................................... 5 Updates for Testing and Verification............................................................ 8 So You Want your Product ENERGY STAR Certified.......................................... 9 Third-Party Testing Options ......................................................................... 9 Data Acceptance Programs........................................................................ 11 Keeping Up with Spec Changes.......................................................................12 Revisions & Development .......................................................................... 12 Updates to the ENERGY STAR Partner Agreement............................................14
    [Show full text]
  • Version 6.1 Computers Program Requirements (Rev
    ® ENERGY STAR Program Requirements for Computers Partner Commitments Following are the terms of the ENERGY STAR Partnership Agreement as it pertains to the manufacture and labeling of ENERGY STAR certified products. The ENERGY STAR Partner must adhere to the following partner commitments: Certified Products 1. Comply with current ENERGY STAR Eligibility Criteria, which define performance requirements and test procedures for Computers. A list of eligible products and their corresponding Eligibility Criteria can be found at www.energystar.gov/specifications. 2. Prior to associating the ENERGY STAR name or mark with any product, obtain written certification of ENERGY STAR qualification from a Certification Body recognized by EPA for Computers. As part of this certification process, products must be tested in a laboratory recognized by EPA to perform Computer testing. A list of EPA-recognized laboratories and certification bodies can be found at www.energystar.gov/testingandverification. 3. Ensure that any model associated with the ENERGY STAR name or mark meets the following standards: 3.1. Product material requirements as defined in restriction of hazardous substances (RoHS) regulations, as generally accepted. This includes exemptions in force at the date of product manufacture, where the maximum concentration values tolerated by weight in homogeneous materials are: lead (0.1%), mercury (0.1%), cadmium (0.01%), hexavalent chromium (0.1%), polybrominated biphenyls (PBB) (0.1%), or polybrominated diphenyl ethers (PBDE) (0.1%). Batteries are exempt. 3.2. The generally accepted attributes of a recyclable product at the date of product manufacture: where products shall be designed for ease of disassembly and recyclability where external enclosures, sub-enclosures, chassis and electronic subassemblies are easily removable with commonly available tools, by hand, or by a recycler's automated processes.
    [Show full text]
  • ENERGY STAR Computers Final Version 8.0 Specification- Rev. April
    ® ENERGY STAR Program Requirements for Computers Partner Commitments Following are the terms of the ENERGY STAR Partnership Agreement as it pertains to the manufacture and labeling of ENERGY STAR certified products. The ENERGY STAR Partner must adhere to the following partner commitments: Certified Products 1. Comply with current ENERGY STAR Eligibility Criteria, which define performance requirements and test procedures for Computers. A list of eligible products and their corresponding Eligibility Criteria can be found at www.energystar.gov/specifications. 2. Prior to associating the ENERGY STAR name or mark with any product, obtain written certification of ENERGY STAR qualification from a Certification Body recognized by EPA for Computers. As part of this certification process, products must be tested in a laboratory recognized by EPA to perform Computer testing. A list of EPA-recognized laboratories and certification bodies can be found at www.energystar.gov/testingandverification. 3. Ensure that any model associated with the ENERGY STAR name or mark meets the following standards: 3.1. Product material requirements as defined in restriction of hazardous substances (RoHS) regulations, as generally accepted. This includes exemptions in force at the date of product manufacture, where the maximum concentration values tolerated by weight in homogeneous materials are: lead (0.1%), mercury (0.1%), cadmium (0.01%), hexavalent chromium (0.1%), polybrominated biphenyls (PBB) (0.1%), or polybrominated diphenyl ethers (PBDE) (0.1%). Batteries are exempt. 3.2. The generally accepted attributes of a recyclable product at the date of product manufacture: where products shall be designed for ease of disassembly and recyclability where external enclosures, sub-enclosures, chassis and electronic subassemblies are easily removable with commonly available tools, by hand, or by a recycler's automated processes.
    [Show full text]
  • ENERGY STAR Lamps V2.1 Final Specification
    ENERGY STAR® Program Requirements for Lamps (Light Bulbs) Partner Commitments Following are the terms of the ENERGY STAR Partnership Agreement as it pertains to the manufacture and labeling of ENERGY STAR certified products. The ENERGY STAR Partner must adhere to the following partner commitments: Certifying Products 1. Comply with current ENERGY STAR Eligibility Criteria, which define performance requirements and test procedures for Lamps. A list of eligible products and their corresponding Eligibility Criteria can be found at www.energystar.gov/specifications. 2. Prior to associating the ENERGY STAR name or mark with any product, obtain written certification of ENERGY STAR certification from a Certification Body recognized by EPA for Lamps. As part of this certification process, products must be tested in a laboratory recognized by EPA to perform Lamp testing. A list of EPA-recognized laboratories and certification bodies can be found at www.energystar.gov/testingandverification. Using the ENERGY STAR Name and Marks 3. Comply with current ENERGY STAR Brand Book, which define how the ENERGY STAR name and marks may be used. Partner is responsible for adhering to these guidelines and ensuring that its authorized representatives, such as advertising agencies, dealers, and distributors, are also in compliance. The ENERGY STAR Brand Book are available at www.energystar.gov/logouse. 4. Use the ENERGY STAR name and marks only in association with certified products. Partner may not refer to itself as an ENERGY STAR Partner unless at least one product is certified and offered for sale in the U.S. and/or ENERGY STAR partner countries. 5. Provide clear and consistent labeling of ENERGY STAR certified Lamps.
    [Show full text]
  • ENERGY STAR Version 3.1 Imaging Equipment Program Requirements
    ENERGY STAR® Program Requirements for Imaging Equipment Partner Commitments Following are the terms of the ENERGY STAR Partnership Agreement as it pertains to the manufacture and labeling of ENERGY STAR qualified products. The ENERGY STAR Partner must adhere to the following partner commitments: Qualifying Products 1. Comply with current ENERGY STAR Eligibility Criteria, which define performance requirements and test procedures for Imaging Equipment. A list of eligible products and their corresponding Eligibility Criteria can be found at www.energystar.gov/specifications. 2. Prior to associating the ENERGY STAR name or mark with any product, obtain written certification of ENERGY STAR qualification from a Certification Body recognized by EPA for Imaging Equipment. As part of this certification process, products must be tested in a laboratory recognized by EPA to perform Imaging Equipment testing. A list of EPA-recognized laboratories and certification bodies can be found at www.energystar.gov/testingandverification. 3. Ensure that any model associated with the ENERGY STAR name or mark meets the following standards: 3.1. Product material requirements as defined in restriction of hazardous substances (RoHS) regulations, as generally accepted. This includes exemptions in force at the date of product manufacture, where the maximum concentration values tolerated by weight in homogeneous materials are: lead (0.1%), mercury (0.1%), cadmium (0.01%), hexavalent chromium (0.1%), polybrominated biphenyls (PBB) (0.1%), polybrominated diphenyl ethers (PBDE) (0.1%), bis(2-ethylhexyl) phthalate (DEHP) (0.1%), benzyl butyl phthalate (BBP) (0.1%), dibutyl phthalate (DBP) (0.1%), or diisobutyl phthalate (DIBP) (0.1%). Batteries are exempt. 3.2. The generally accepted attributes of a recyclable product at the date of product manufacture: where products shall be designed for ease of disassembly and recyclability where external enclosures, sub-enclosures, chassis and electronic subassemblies are easily removable by hand with commonly available tools.
    [Show full text]