Characterization of Functionalized Polyolefins by High

Total Page:16

File Type:pdf, Size:1020Kb

Characterization of Functionalized Polyolefins by High Reprinted from American Laboratory January 2011 Application Note by Anton Ginzburg, Tibor Macko, and Robert Brüll way. Another drawback is that TREF is a Characterization of Functionalized relatively time-consuming technique. The method of choice when it comes to sepa- Polyolefins by High-Temperature rating complex polymers with regard to their chemical composition is HPLC. Separation in HPLC can be achieved via different mecha- nisms, including adsorption–desorption and Two-Dimensional Liquid precipitation–redissolution.6 However, HPLC has thus far been limited to polymers that are soluble at room temperature. The authors’ Chromatography group developed the first interactive HPLC systems for the separation of functionalized unctionalized polyolefins, such as such as branching, and by the chemical com- polyolefins at high temperatures.7–9 It was copolymers of ethylene vinyl ace- position via affinity toward the used solvent. shown that EVA copolymers,7–9ethylene tate (EVA), are a commercially This means that macromolecules having the methyl acrylate copolymers,8 and ethylene important polymer commodity. identical hydrodynamic volume but different butyl acrylate8 can be separated according to FDepending on their comonomer con- chemical composition may coelute at the their chemical composition at a temperature tent, these materials find application in same elution volume in SEC. of 140 °C using silica gel as stationary phase the production of foams, films, and hot and gradients of nonpolar/polar solvents as melt adhesives. The polyolefin market is Crystallization fractionation (CRYSTAF) mobile phase. To characterize the chemi- growing by 5–6% annually due to its ver- and temperature-rising elution fraction- cal heterogeneity, i.e., the relationship of satile physical and mechanical properties, ation (TREF) are commonly used to deter- CCD and MMD (hyphenation of interac- low cost, and easily available raw materi- mine the CCD of semicrystalline olefin tive HPLC with SEC), 2D-LC separation is als.1 As a result, the characterization of copolymers. Both techniques utilize the required. The advantages and disadvantages functionalized polyolefins has become an relationship between comonomer content of using either HPLC-SEC or SEC-HPLC important area in polymer research.2 and the crystallizability from a hot dilute sequences have been discussed in detail by solution, which is derived from Flory’s the- van der Horst et al.10 Olefin copolymers are generally distributed ory.3 TREF can also be hyphenated with with regard to various parameters such as SEC to reveal the full chemical heteroge- At present, standard 2D-LC procedures chemical composition, molar mass, func- neity.4,5 This can be done either off-line4 and instruments are limited to separation tionality, degree of branching, block length, or on-line.5 However, the entire approach at ambient temperatures,11 and therefore and tacticity. Comprehensive characteriza- is limited to well-crystallized samples; thus cannot be applied to the characterization tion of the interrelationship between these samples with a higher content of comono- of semicrystalline polyolefins. This paper distributions is therefore essential to under- mer (>10 wt%) cannot be studied in this describes the coupling of the interac- standing the catalyst performance, as well as to optimizing the synthesis and structure– property relationships. In the case of func- tionalized polyolefins, the most important distributions are molar mass distribution (MMD) and chemical composition distri- bution (CCD), and their interrelationship is referred to as chemical heterogeneity. A number of fractionation techniques are commonly used in polyolefin analysis. High- temperature-size exclusion chromatogra- phy (HT-SEC) is the established method to determine the MMD. SEC separation is based on the size of the molecules in solu- tion (hydrodynamic volume) and the extent to which they are excluded from the pores of a stationary phase. The MMD and cor- responding molar mass averages can be obtained from a calibration curve that relates the molar mass to the elution volume, or by using on-line molar mass detectors such as light scattering or viscosimetry. However, the size of a macromolecule in solution is also influenced by its molecular architecture, Figure 1 HT-2D-LC schematic. Figure 4 Chromatogram obtained from the Figure 2 Photograph of the HT-2D-LC system. Figure 3 Chromatogram corresponding to the SEC separation of the mixture of five polymers: PE HPLC separation of the mixture of five polymers: PE (Mw = 1.18 kg/mol), PVAc (Mw = 37 kg/ (Mw = 1.18 kg/mol), PVAc (Mw = 37 kg/mol), and mol), and EVAs (19, 45, and 80 wt% VA, tive HT-HPLC system developed by the EVAs (19, 45, and 80 wt% VA, respectively). respectively). Experimental conditions described in authors’ group with SEC, and application Experimental conditions described in the text. the text. of HT-2D-LC for the characterization of commercial functional polyolefins. column size 250 × 4.5 mm i.d., and aver- Results and discussion age particle size diameter 5 µm (MZ Experimental Analysentechnik, Mainz, Germany). TCB For the separation of commercial EVAs and cyclohexanone were used as the com- according to chemical composition, a sorbent/ Polymers and solvents ponents of the mobile phase with a flow solvent system developed in the authors’ labo- 1,2,4-Trichlorobenzene (TCB) and cyclo- rate of 0.1 mL/min. ratory7 was applied that separates the EVA hexanone (Merck, Darmstadt, Germany) macromolecules with regard to their content were used as components of the mobile A PL Rapide H column, 150 × 7.5 mm of the polar comonomer. The polar copoly- phase. The polymer samples were dissolved (Polymer Laboratories, Church Stretton, mers were first fully adsorbed on silica gel from in TCB at a concentration of 3 mg/mL at U.K.), was used in the second dimension TCB and subsequently desorbed according to a temperature of 140 °C; 200 µL of the (SEC). TCB was used as the mobile phase their comonomer content by applying a gradi- sample solutions was injected and analyzed in the SEC column at a flow rate of 2.5 ent of cyclohexanone.7 A blend of five com- by 2D-LC. mL/min. A calibration curve for that col- ponents, including the PVAc, polyethylene umn was obtained with 11 polystyrene (PE), and three EVA copolymers varying in EVA copolymers were products of Bayer standards at a flow rate of 2.5 mL/min. The their average VA content, was prepared. The (Leverkusen, Germany). Polystyrene stan- temperature of the autosampler and both chromatogram in SEC and HPLC are shown dards (PS) with weight-average molar masses column ovens was set to 140 °C. in Figures 3 and 4. (Mw) in the range 0.687–2570 kg/mol (poly- dispersity index between 1.02 and 1.07) as The HPLC and SEC columns were con- SEC shows a multimodal distribution, but well as polyvinyl acetate (PVAc) (Mw = nected via an electronically controlled it is not possible to recognize that the num- 37 kg/mol) were obtained from Polymer eight-port valve system (VICI Valco ber of components as macromolecules with Standards Service (Mainz, Germany). Instruments, Houston, TX) with two 200- different chemical composition coelute in µL loops. From the moment of injection SEC (Figure 3). No information about the into the HPLC column, the eight-port MMD of macromolecules with different Instrumentation valve was switched every 2 min in order chemical composition can be obtained from Separations were achieved on a proto- to inject 200 µL of effluent from the HPLC the HPLC chromatogram alone (Figure 4). type system for high-temperature two- column into the SEC column. dimensional chromatography, constructed To study the chemical heterogeneity interre- by Polymer Char (Valencia, Spain). An evaporative light scattering detector lationship, HT-HPLC must be hyphenated The system consisted of an autosam- (ELSD, model PL-ELS 1000, Polymer to SEC. On-line hyphenation of HT-HPLC pler, two column ovens, valves, and two Laboratories) was used for detection after and HT-SEC was achieved in the 2D-LC pumps (Agilent, Waldbronn, Germany). the SEC. The ELSD was operated at a instrument, in which both chromatographic A binary gradient pump was used for the nebulization temperature of 140 °C, an modes were connected on-line by an elec- HPLC analysis and an isocratic pump was evaporation temperature of 260 °C, and an tronically controlled eight-port valve system used for SEC. Figure 1 is a schematic of the airflow of 1.5 L/min. equipped with two 200-µL loops. The two 2D-LC instrument; a photograph of the loops were used alternately in the symmetri- system is presented in Figure 2. 2D-LC system handling was done with cal configuration to store the effluent from software provided by Polymer Char. the first-dimension column and to subse- Separations in the first dimension were WinGPC-software (Polymer Standards quently inject it into the second-dimension carried out on a silica gel Nucleosil 500 Service) was used for data acquisition and column. While one sample fraction from the column with the following parameters: construction of 2-D contour plots. first dimension was being injected and ana- Two-dimensional liquid chromatography is experimentally more demanding than other chromatographic techniques. How- ever, the complete characterization yields qualitatively new information about the polymer material, and results can be pre- sented in an impressively simple way. References 1. Kaminsky, W. Macromol. Chem. Phys. 2008, 209, 459–66. 2. Yanjarappa, M.J.; Sivaram, S. Progress Polym. Sci. 2002, 27, 1347–98. 3. Flory, P.J. J. Chem. Phys. 1949, 17, 223– 40. 4. Wild, L. Adv. Polym. Sci. 1991, 98, 1. 5. Ortin, A.; Monrabal, B.; Sancho-Tello, J. Macromol. Symp. 2007, 257, 13–28. 6. Pasch, H.; Trathnigg, B. HPLC of Polymers; Springer: Berlin, 1997. Figure 5 HT-2D-LC separation of the mixture of five polymers: PE (Mw = 1.18 kg/mol), PVAc (Mw = 37 7.
Recommended publications
  • Detector Gel Permeation Chromatography
    Methods of long chain branching detection in PE by triple-detector gel permeation chromatography Thipphaya Pathaweeisariyakul,1 Kanyanut Narkchamnan,1 Boonyakeat Thitisuk,1 Wallace Yau2 1Siam Cement Group (SCG), SCG Chemicals Co., Ltd., 10 I-1 Road, Map Ta Phut Industrial Estate, Muang District, Rayong Province 21150, Thailand 2Polymer Characterization Consultant, USA, www.linkedin.com/pub/wallace-yau Correspondence to: T. Pathaweeisariyakul (E-mail: [email protected]) ABSTRACT: Long chain branching (LCB) in polyethylene is one of the key microstructures that controls processing and final proper- ties. Gel permeation chromatography (GPC) with viscometer (IV) and/or light scattering (LS) has been intensely used to quantify LCB. The widespread method to quantify LCB from GPC with IV or LS is the method of LCB frequency (LCBf) based on the Zimm–Stockmayer (ZS) random branching model. In this work, the conventional approach was compared with the recently devel- oped method, called gpcBR. The comparison of the sensitivity of both methods is made on highly branched polymer, that is, various grades of commercial LDPE and also on polymer with very low level of LCB, that is, a commercial HDPE with no LCB, converted into several branched test samples of gradually increasing LCB by multiple extrusion. Finally, the linkages of LCB quantities from both methods to the rheological data and processing properties are illustrated. The new gpcBR index can access lower LCB level and shows obviously better relationship with both rheological data and processing properties than LCBf from the conventional ZS model. VC 2015 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2015, 132, 42222.
    [Show full text]
  • Tgic Thermal Gradient Interaction Chromatography
    TGIC THERMAL GRADIENT INTERACTION CHROMATOGRAPHY A new and fully automated Thermal Gradient Interaction Chromatograph for measuring Composition Distribution in Elastomers and Low Crystallinity Polyolefin Copolymers. High Temperature HPLC has become recently available for the KEY FEATURES analysis of polyolefins, field where it is better known under the name of Interaction Chromatography. It was first used in Fully automated operation with no manual solvent handling. Integrated Solvent Gradient Interaction Chromatography mode (SGIC) vial solvent filling, sample dissolution and in-line filtration. and it is today extended with the use of a thermal gradient Fast analysis time of around 2-3 hours including sample dissolution. instead, also known as Thermal Gradient Interaction Chromatography (TGIC). Analysis of up to 40 samples sequentially, with the possibility of using different methods each one. The TGIC technique using carbon based adsorbents was Both TGIC and CEF analyses can be performed in the same instrument developed by The Dow Chemical Company to characterize the with dedicated software packages. composition distribution in polyethylene copolymers. This technique requires a cooling (adsorption) and a heating Easy incorporation of Polymer Char’s on-line Viscometer for composition- (desorption) step. Elution of the sample takes place in that last molar mass interdependence. heating step, observing a linear dependence of comonomer content to desorption temperatures in a similar manner to TREF Option to integrate IR5 MCT detector for maximum sensitivity in both and CEF, and being molar mass independent above 20,000 Da. concentration and composition signals. TGIC will adsorb polymer molecules by the level of molecular surface in contact with the surface of the adsorbent, thus it 20 TGIC 20/2/0.5 Carbon-based Column 10 cm o-DCB may discriminate polymers by the level of irregularities in the 18 chain, in a similar approach to crystallization techniques.
    [Show full text]
  • 4Th International Conference on Polyolefin Characterization
    4th International Conference on Polyolefin Characterization October 21-24, 2012, The Woodlands, TX, U.S.A. WELCOME LETTER Welcome to the International Polyolefin Characterization Meeting Point par excellence. Dear ICPC Delegate, Welcome to the 4th edition of the International Conference on Polyolefin Characterization. After successful previous editions in Houston, Valencia and Shanghai, we are proud to host this forth edition again in Texas, as a leading centre in the field of polyolefin research. Once more, the 4th ICPC Conference will focus on the latest developments and innovative research in the characterization of polyolefins, grouped into sessions on Separation, Morphology, Rheology, Spectroscopy and Mathematical Modeling. An outstanding technical program, composed of 41 lectures and 38 posters, will shape this 2012 edition, together with vendor presentations, a booth area, a companions program for attendee’s family, and networking cocktails in the evenings that we encourage you to attend. Additionally, the 4th ICPC Short Course on Polyolefin Characterization Techniques will be held on the first day of the meeting. This one-day training course represents a unique scenario where the world experts in the field share their knowledge and experiences in GPC/SEC, Chemical Composition Distribution, High Temperature HPLC, Cross Fractionation and Preparative Fractionation techniques. The 4th ICPC will provide once more a platform to bring together researchers from both industry and academia. With attendees from around 20 countries and representing over 50 different organizations that play a key-role in the research or production of polyolefins, ICPC covers again the whole world map, becoming this way a truly unique international conference on the field of polyolefin characterization.
    [Show full text]
  • An Alternative Method for Long Chain Branching Determination by Triple-Detector Gel Permeation Chromatography
    Polymer 107 (2016) 122e129 Contents lists available at ScienceDirect Polymer journal homepage: www.elsevier.com/locate/polymer An alternative method for long chain branching determination by triple-detector gel permeation chromatography * Thipphaya Pathaweeisariyakul a, , Kanyanut Narkchamnan a, Boonyakeat Thitisak a, Wonchalerm Rungswang a, Wallace W. Yau b a SCG Chemicals Co., Ltd., 1 Siam Cement Rd., Bangsue, Bangkok 10800, Thailand b Polymer Characterization Consultant, 7755 Tim Tam Ave., Las Vegas, NV 89178, USA article info abstract Article history: Gel permeation chromatography with refractive index (RI) or infrared detector (IR), viscometer for Received 8 August 2016 intrinsic viscosity (IV) and/or light scattering (LS) has become a prominent technique for quantitative Received in revised form study of polymer long chain branching (LCB). A quantity known as LCB frequency (LCBf) derived from g- 14 October 2016 factor of Zimm-Stockmayer (ZS) model was here studied and found its problems in reproducibility and Accepted 5 November 2016 accuracy. In this work, an alternative high precision method of the gpcBR approach was used to estimate Available online 8 November 2016 a more reliable g-factor, called gest. The branching index, B-factor for number of LCB per molecule was found to be more relevant than LCBf in relating to polymer properties. A proposal is made that enables Keywords: Long chain branch the distinction between two LCB categories, i.e. branch on main chain and branch on branch. This allows GPC the analysis of these two LCB types on their relative importance to polymer processing and end-use Light Scattering properties. NMR results were obtained in support of the LCB data.
    [Show full text]
  • NIST HPLC/SEC Paper
    pubs.acs.org/Macromolecules Article Design and Characterization of Model Linear Low-Density Polyethylenes (LLDPEs) by Multidetector Size Exclusion Chromatography Sara V. Orski, Luke A. Kassekert, Wesley S. Farrell, Grace A. Kenlaw, Marc A. Hillmyer, and Kathryn L. Beers* Cite This: Macromolecules 2020, 53, 2344−2353 Read Online ACCESS Metrics & More Article Recommendations *sı Supporting Information ABSTRACT: Separations of commercial polyethylenes, which often involve mixtures and copolymers of linear, short-chain branched, and long-chain branched chains, can be very challenging to optimize as species with similar hydrodynamic sizes or solubility often coelute in various chromatographic methods. To better understand the effects of polymer structure on the dilute solution properties of polyolefins, a family of model linear low-density polyethylenes (LLDPEs) were synthesized by ring-opening metathesis polymerization (ROMP) of sterically hindered, alkyl-substituted cyclooctenes, followed by hydrogenation. Within this series, the alkyl branch frequency was fixed while systematically varying the short-chain branch length. These model materials were analyzed by ambient- and high-temperature size exclusion chromatography (HT-SEC) to determine their molar mass, intrinsic viscosity ([η]), and degree of short-chain branching across their respective molar mass distributions. Short-chain branching is fixed across the molar mass distribution, based on the synthetic strategy used, and measured values agree with theoretical values for longer alkyl branches, as evident by HT-SEC. Deviation from theoretical values is observed for ethyl branched LLDPEs when calibrated using either α-olefin copolymers (poly(ethylene-stat-1-octene)) or blends of polyethylene and polypropylene standards. A systematic decrease of intrinsic viscosity is observed with increasing branch length across the entire molar mass distribution.
    [Show full text]
  • Quality and Process Control in PE and PP Manufacturing Separation Solutions for Plants and QC Laboratories Contents
    Quality and Process control in PE and PP Manufacturing Separation Solutions for Plants and QC Laboratories Contents 6 AN OVERVIEW: NEWLY DEVELOPED RESINS ARE MORE CHALLENGING TO CONTROL IN PRODUCTION PLANTS 15 CRSYTEX® QC 18 APPLICATION NOTE: SOLUBLE FRACTION FOR POLYPROPYLENE PRODUCTION PLANTS 25 CRYSTEX® 42 29 GPC-QC 32 APPLICATION NOTE: GPC FOR PROCESS AND QUALITY CONTRON IN PE AND PP MANUFACTURING 39 INTRINSIC VISCOSITY ANALYZER, IVA 42 APPLICATION NOTE: INTRINSIC VISCOSITY DETERMINATION FOR POLYMERIC MATERIALS 49 UPCOMING INNOVATION: CEF QC 05 SEPARATION SOLUTIONS FOR AMORPHOUS FRACTION PLANTS AND QC LABORATORIES CRYSTEX® QC Complete automation of the Soluble Fraction measurement in polypropylene while quantifying the ethylene content and intrinsic viscosity in the whole sample, and the soluble and crystallyne fractions. Analysis of one sample at-a-time in approximately 2.5 hours (Page 15). MOLAR MASS DISTRIBUTION GPC-QC CRYSTEX® 42 Simplified and fully-automated GPC instrument for control This intrument shares the same analytical concept as laboratories in polyolefin production plants. Provides robust CRYSTEX® QC, but it uses a high-temperature autosampler and precise Molar Mass Distribution data for process with 42 positions, ideal for a central laboratory, where large control, in a simplified and automated wrokflow, for one batches of pelletized, more homogeneous samples need to sample at-a-time in 30 minutes (Page 29). be analyzed in sequence (Page 25). INTRINSIC VISCOSITY CHEMICAL COMPOSITION DISTRIBUTION IVA CEF QC (upcoming) Fully-automated instrument for the Intrinsic Viscosity A simplified CEF for production plants to obtain the complete analysis of all polymeric materials, even the very challenging chemical composition distribution curve for one sample in ones that can require temperatures of up to 200ºC for less than 1h (incl.
    [Show full text]
  • Rheology of Crystallizing LLDPE
    Rheology of Crystallizing LLDPE Marat Andreeva, David Nicholsona, Anthony Kotulab, Jonathan Moorec, Jaap den Doelderd,e, Gregory C. Rutledgea* aDepartment of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA bNational Institute of Standards and Technology, Gaithersburg, MD cThe Dow Chemical Company, Midland, MI dDow Benelux BV, Terneuzen, The Netherlands eLaboratory of Physical Chemistry, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology. Eindhoven, The Netherlands Abstract Polymer crystallization occurs in many plastic manufacturing processes, from injection molding to film blowing. Linear low-density polyethylene (LLDPE) is one of the most commonly processed polymers, wherein the type and extent of short-chain branching (SCB) may be varied to influence crystallization. In this work, we report simultaneous measurements of the rheology and Raman spectra, using a Rheo-Raman microscope, for two industrial-grade LLDPEs undergoing crystallization. These polymers are characterized by broad polydispersity, SCB and the presence of polymer chain entanglements. The rheological behavior of these entangled LLDPE melts is modeled as a function of crystallinity using a slip-link model. The partially crystallized melt is represented by a blend of linear chains with either free or crosslinked ends, wherein the crosslinks represent attachment to growing crystallites, and a modulus shift factor that increases with degree of crystallinity. In contrast to our previous application of the slip-link model to isotactic polypropylene (iPP), in which the introduction of only bridging segments with crosslinks at both ends was sufficient to describe the available data, for these LLDPEs we find it necessary to introduce dangling segments, with crosslinks at only one end. The model captures quantitatively the evolution of viscosity and elasticity with crystallization over the whole range of frequencies in the linear regime for two LLDPE grades.
    [Show full text]
  • Method Development in Interaction Polymer Chromatography
    Trends in Analytical Chemistry 130 (2020) 115990 Contents lists available at ScienceDirect Trends in Analytical Chemistry journal homepage: www.elsevier.com/locate/trac Method development in interaction polymer chromatography Andre M. Striegel Chemical Sciences Division, National Institute of Standards & Technology (NIST), 100 Bureau Drive, MS 8390, Gaithersburg, MD, 20899-8390, USA article info abstract Article history: Interaction polymer chromatography (IPC) is an umbrella term covering a large variety of primarily Available online 29 July 2020 enthalpically-dominated macromolecular separation methods. These include temperature-gradient interaction chromatography, interactive gradient polymer elution chromatography (GPEC), barrier Keywords: methods, etc. Also included are methods such as liquid chromatography at the critical conditions and Interaction chromatography GPEC in traditional precipitation-redissolution mode. IPC techniques are employed to determine the Polymers chemical composition distribution of copolymers, to separate multicomponent polymeric samples ac- Characterization cording to their chemical constituents, to determine the tacticity and end-group distribution of polymers, Method development Fundamentals and to determine the chemical composition and molar mass distributions of select blocks in block co- polymers. These are all properties which greatly affect the processing and end-use behavior of macro- molecules. While extremely powerful, IPC methods are rarely employed outside academic and select industrial laboratories.
    [Show full text]
  • Chain Branches in a Low-Density Polyethylene
    www.nature.com/scientificreports OPEN Direct Observation of Long- Chain Branches in a Low-Density Polyethylene Received: 26 November 2018 Ken-ichi Shinohara 1, Masahiro Yanagisawa2 & Yuu Makida1 Accepted: 18 June 2019 Low-density polyethylene (LDPE) has short-chain branch (SCB) and long-chain branch (LCB). In Published: xx xx xxxx particular, the infuence of the structure of LCBs on polymer properties is remarkable; however, it has been difcult to precisely analyze LCB structures. In this study, we measured the chain length of LCBs and the distance between branch points of LDPE by atomic force microscopy. Consequently, three LCBs were confrmed in a main chain of 162 nm, and their length were measured as 10, 31, and 18 nm. The positions of the LCBs were 33, 70, and 78 nm from the main-chain end. Te properties of a polymer change signifcantly depending on the structure of the polymer chain, particularly, with branched structures, depending on the number of branches and the length of the branch1–5. However, the long-chain branch (LCB) structure of polyethylene was unclear, due particularly to the complex polymer struc- ture and the limitations of its analysis methods. Tus, in this study, we aimed to directly observe the LCB struc- tures in low-density polyethylene (LDPE). Specifcally, single-molecule imaging was performed by an atomic force microscopy, which improved the structural observation of the polymer chain6–11 and allowed direct obser- vation of the number and length of LCBs in LDPE, the positions of the branch points, and the distance between them. Experimental LDPE sample.
    [Show full text]
  • Crystex® Qc Automated Soluble Fraction Analyzer
    CRYSTEX® QC AUTOMATED SOLUBLE FRACTION ANALYZER Reliable and automated instrument for KEY FEATURES Amorphous Fraction determination in Quality Fully-automated analysis of the soluble (amorphous) fraction in Control laboratories of Polypropylene plants. polypropylene and other polyolefins. CRYSTEX® QC is a step forward in technology for automating A sample can be analyzed every 2.5 hours (including dissolution and the Soluble Fraction determination (amorphous fraction) in rinsing time) without manual operation. polypropylene and other polyolefin resins. This is a reliable No need for accurate weighing of sample nor manual solvent handling. instrument for continuous operation in the manufacturing plant laboratory, with minimum bench-space and utilities No external filtration nor solvent evaporation required. requirements. Additional measurement of ethylene content and intrinsic viscosity for the CRYSTEX® QC stands as a modern alternative to the traditional fraction, the crystalline fraction, and whole sample. wet chemistry method based on xylene solubility, which is known For Process/QC laboratories in production plants. for being very time consuming and for requiring constant manual handling of solvent at high temperature. In comparison, Compatible with other polyolefin materials such as LDPE, and adaptable CRYSTEX® QC is very easy to operate, and obtaining the to other solubility tests (heptane or hexane solubles). amorphous phase content in a shorter time. It also eliminates the need to handle solvent manually and it uses less flammable Soluble Fraction Crystalline Fraction Whole Sample solvents than Xylene (TCB or oDCB), increasing the safety level in the laboratory. Weight % Weight % Ethylene Content % Ethylene Content % Ethylene Content % Intrinsic Viscosity The only manual task required is to put a representative amount of sample (up to 4g) in a disposable bottle, without the need Intrinsic Viscosity Intrinsic Viscosity of accurate weighing.
    [Show full text]
  • Newly Developed Resins More Challenging to Control In
    48-51 Polymer Char Tech Paper_046854 IndustryNews.QXD 4/20/18 7:11 AM Page 48 TECHNICAL ARTICLE Newly Developed Resins More Challenging to Control in Production Plants Developments in resins have opened up a whole new world of design choices, but challenges remain because current quality control parameters only show part of the picture By B. Monrabal, A. Ortín, and P. del Hierro Polymer Char, Valencia, Spain he introduction of single-site catalysts and the use of multiple reactors in the polyolefins industry has opened new routes to design resins with the desirable microstructure to optimize performance in specific applications. While this is good news for manufactur- Ting, it presents a greater challenge for quality control because the currently used parameters show only partial information of the resin microstructure. Melt Index (MI) and density are common parameters in simplified design for quality control purposes (GPC-QC). process control and product definition that represent aver- A similar situation is that of PE copolymers, such as the three age molar mass and average composition respectively. LLDPE resins shown in Figure 2. They all have the same However, with today’s sophisticated industrial resins, these comonomer content, expressed with the density parameter, parameters are very far from defining resin performance. A set of analytical techniques has been recently developed to detail additional parameters relevant to the resin perform- ance. Same Resins, Different Performance? Within the polyethylene (PE) family, the added information is essential, especially in the case in dual reactor resins––as with pipe and blow molding products––or in the broad spec- trum of linear low-density polyethylene (LLDPE) resins.
    [Show full text]
  • Sgic 2D Solvent Gradient Interaction Chromatography X Gpc
    SGIC 2D SOLVENT GRADIENT INTERACTION CHROMATOGRAPHY X GPC A fully automated system to determine chemical KEY FEATURES composition distribution and molar mass Fully automated instrument to measure the chemical composition - molar interdependence by Solvent Gradient Interaction mass interdependence of complex and functional Polyolefins. Chromatography (SGIC) combined with GPC/SEC. Of special interest for polar or low crystallinity Polyolefins. The Two-Dimensional Solvent Gradient Interaction Detection performed in TCB and in isocratic mode: a linear IR detector Chromatograph (SGIC 2D) instrument performs an analytical can be used instead of a non-linear ELSD. Compatible with molar-mass fractionation of the polymer according to chemical composition -sensitive detectors. by selective adsorption/desorption on a HPLC column, followed No solvents handling, fully automated process, including in-line filtration. by a second separation according to molar mass on a GPC/SEC column, being the only high temperature SGIC system available Flexible definition of the number of fractions and the solvent gradient in the market. profile. Bivariate distribution results presented as contour or 3D surface graphs. The instrument is fully automated and the whole process is controlled by the virtual instrumentation software. Once the vials Automated analysis of a sequence of samples, with flexibility to use with the dry polymer samples are placed in the autosampler’s different methods for each one. external tray, the instrument takes care of the vial-filling with solvent, dissolution with gentle shaking, optional in-line filtration, and injection into the HPLC column. Then the solvent gradient program starts, and the resulting fractions are injected towards the GPC/SEC columns.
    [Show full text]