Detector Technology Evaluation

Total Page:16

File Type:pdf, Size:1020Kb

Detector Technology Evaluation Detector Technology Evaluation Dr. Peter T. Martin, Associate Professor University of Utah Yuqi Feng, Xiaodong Wang Research Assistants Department of Civil and Environmental Engineering University of Utah Traffic Lab 122 South Central Campus Drive November 2003 Acknowledgements The research presented in this paper was supported by finding from the Mountain Plains Consortium (U.S. Department of Transportation) and the Utah Department of Transportation through the Utah Transportation Center. Disclaimer The contents of this report reflect the views of the authors, who are responsible for the facts and the accuracy of the information presented. This document is disseminated under the sponsorship of the Department of Transportation, University Transportation Centers Program, in the interest of information exchange. The U.S. Government assumes no liability for the contents or use thereof. ii TABLE OF CONTENTS 1. INTRODUCTION....................................................................................................................1 2. PROJECT GOALS AND OBJECTIVES.................................................................................3 3. TRAFFIC DATA NEEDS AND DETECTOR APPLICATIONS.............................................5 3.1 Traffic Data Needs ............................................................................................................5 3.2 Detector Applications ........................................................................................................8 3.2.1 Historical Data Collections .....................................................................................8 3.2.2 Real-time Data Collections .....................................................................................8 3.3 Current Practices With Detector Technologies ..................................................................12 3.3.1 Surveys on Departments of Transportation .............................................................12 3.3.2 Guidelines and Standards ......................................................................................17 4. STATE-OF-THE-ART DETECTOR TECHNOLOGIES ......................................................19 4.1 Intrusive Detector Technologies.......................................................................................19 4.1.1 Inductive Loop .....................................................................................................19 4.1.2 Magnetic Detector ................................................................................................23 4.1.3 Pneumatic Road Tube...........................................................................................26 4.1.4 Piezoelectric ........................................................................................................27 4.1.5 Weigh-in-Motion (WIM) ......................................................................................29 4.2 Non-intrusive Detector Technologies................................................................................33 4.2.1 Active and Passive Infrared...................................................................................33 4.2.2 Microwave Radar.................................................................................................36 4.2.3 Ultrasonic and Passive Acoustic ............................................................................38 4.2.4 Video Image Processing (VIP)..............................................................................40 4.2.5 Combined Detector Technologies..........................................................................45 4.3 Off-roadway Technologies ..............................................................................................45 4.3.1 Probe Vehicle ......................................................................................................45 4.3.2 Remote Sensing ...................................................................................................49 4.4 Manual Counting Equipment ...........................................................................................49 4.5 Pedestrian and Bicycle Detection .....................................................................................51 References ...........................................................................................................................54 5. DETECTOR TECHNOLOGY EVALUATION AND SELECTION......................................57 5.1 Data Type.......................................................................................................................57 5.2 Data Accuracy................................................................................................................62 5.2.1 Field Evaluation Results .......................................................................................66 5.2.2 Environmental and Traffic Impacts........................................................................77 5.2.3 Best Performance Technologies for Traffic Monitoring and Intersection Signal Control Applications .........................................................................................83 5.3 Ease of Installation ..........................................................................................................85 5.4 Cost ............................................................................................................................91 5.5 Other Issues.................................................................................................................. 103 5.6 Advantages and Disadvantages ...................................................................................... 107 5.7 Procedure of Detector Technology Selection................................................................... 109 5.7.1 Permanent Application ....................................................................................... 109 5.7.2 Temporary Application ....................................................................................... 116 References ......................................................................................................................... 118 iii 6. CONCLUSIONS..................................................................................................................121 7. RECOMMENDATIONS......................................................................................................123 APPENDIX: VENDOR LISTS IN THE REPORT ..................................................................125 iv LIST OF FIGURES Figure 3.1: Actuated Isolated Intersection Signal Control..........................................................9 Figure 3.2: Traffic Responsive Ramp Metering Control System...............................................11 Figure 4.1: Principal Components of an Inductive Loop Detector.............................................20 Figure 4.2: Preformed Inductive Loop....................................................................................21 Figure 4.3: Inductive Loop Detectors....................................................................................22 Figure 4.4: Distortion of Earth’s Magnetic Field Created as a Vehicle Enters and Passes Through the Detection Zone of a Magnetic Sensor. ..............................................24 Figure 4.5: SPVD .................................................................................................................25 Figure 4.6: 3M™ Canoga™ Vehicle Detection System...........................................................25 Figure 4.7: JAMAR TRAX I PLUS.......................................................................................27 Figure 4.8: A Typical Piezocable Configuration......................................................................28 Figure 4.9: Kistler LINEAS Quartz Sensor.............................................................................28 Figure 4.10: Comparison Between Ordinary Piezocables and LINEAS Quartz Sensors .............29 Figure 4.11: A Bending Plate.................................................................................................30 Figure 4.12: A Load Cell WIM System..................................................................................31 Figure 4.13: Truck Driving Over Portable Capacitive Mat WIM System..................................31 Figure 4.14: Typical Portable Fiber Optics Sensor Installation.................................................32 Figure 4.15: Laser Detector Beam Geometry..........................................................................33 Figure 4.16: Emission and Reflection of Energy by Vehicle and Road Surface .........................34 Figure 4.17: Passive Infrared Detectors..................................................................................35 Figure 4.18: Autosense II......................................................................................................35 Figure 4.19: Microwave Detector Operation ...........................................................................36 Figure 4.20: True Presence Microwave Radar Detectors..........................................................37 Figure 4.21: Doppler Microwave Radar Detectors ..................................................................38 Figure 4.22: Ultrasonic Detectors...........................................................................................39 v Figure 4.23: Passive Acoustic Detectors.................................................................................40
Recommended publications
  • The Stage Is Set
    The Stage Is Set: Developments before 1900 Leading to Practical Wireless Communication Darrel T. Emerson National Radio Astronomy Observatory1, 949 N. Cherry Avenue, Tucson, AZ 85721 In 1909, Guglielmo Marconi and Carl Ferdinand Braun were awarded the Nobel Prize in Physics "in recognition of their contributions to the development of wireless telegraphy." In the Nobel Prize Presentation Speech by the President of the Royal Swedish Academy of Sciences [1], tribute was first paid to the earlier theorists and experimentalists. “It was Faraday with his unique penetrating power of mind, who first suspected a close connection between the phenomena of light and electricity, and it was Maxwell who transformed his bold concepts and thoughts into mathematical language, and finally, it was Hertz who through his classical experiments showed that the new ideas as to the nature of electricity and light had a real basis in fact.” These and many other scientists set the stage for the rapid development of wireless communication starting in the last decade of the 19th century. I. INTRODUCTION A key factor in the development of wireless communication, as opposed to pure research into the science of electromagnetic waves and phenomena, was simply the motivation to make it work. More than anyone else, Marconi was to provide that. However, for the possibility of wireless communication to be treated as a serious possibility in the first place and for it to be able to develop, there had to be an adequate theoretical and technological background. Electromagnetic theory, itself based on earlier experiment and theory, had to be sufficiently developed that 1.
    [Show full text]
  • Oipeec Canova Final Paper 2009
    OIPEEC Conference / 3 rd International Ropedays - Stuttgart - March 2009 Aldo Canova (1), Fabio Degasperi (2), Francesco Ficili (4), Michele Forzan (3), Bruno Vusini (1) (1) Dipartimento di Ingegneria Elettrica - Politecnico di Torino (Italy) (2) Laboratorio Tecnologico Impianti a Fune (Latif) – Ravina di Trento, Trento (Italy) (3) Dipartimento di Ingegneria Elettrica - Università di Padova (Italy) (4) AMC Instruments – Spin off del Politecnico di Torino (Italy) Experimental and numerical characterisation of ferromagnetic ropes and non-destructive testing devices Summary The paper mainly deals with the magnetic characterisation of ferromagnetic ropes. The knowledge of the magnetic characteristic is useful in the design of non- destructive testing equipments with particular reference to the design of magnetic circuit in order to reach the required rope magnetic behaviour point. The paper is divided in two main section. In the first part a description of the experimental procedure and of the provided setup devoted to the measurement of the non linear magnetic characteristic of different rope manufactures and different typology is presented. In the second part of the paper the magnetic model of the ropes is adopted for the simulation of a non-destructive device under working conditions. The simulation are provided with a non linear three dimensional numerical code based on Finite Integration Technique. Finally the numerical results are compared with some experimental tests under working conditions. 1 Introduction In addition to satisfying the requirements for the eligibility of magneto-inductive devices for control of rope for people transport equipment, defined by relevant national and European directives, one of the major performances required from a magneto inductive device is to provide an LF or LMA [1] signal (LF: Localized Fault and LMA Loss Metallic Area) with high signal-noise ratio.
    [Show full text]
  • History of Naval Ships Wireless Systems I
    History of Naval Ships Wireless Systems I 1890’s to the 1920’s Wireless telegraphy was introduced in to the RN in 1897 by Marconi and Captain HB Jackson, a Torpedo specialist. There was no way to measure wavelength and tuning was in its infancy. Transmission was achieved by use of a spark gap transmitter and the frequency was dependent upon the size and configuration of the aerial. As a result, there was only one wireless channel as the electromagnetic energy leaving the antenna would cover an extremely wide frequency band. The receiver consisted of a similar aerial and the use of a "coherer" which detected EM waves. A battery operated circuit then operated a telegraph "inker" which displayed the signal visually on tape. There was no means of tuning the receiver except to make the aerial the same size as that of the transmitter. It could not distinguish between atmospherics and signals and if two stations transmitted at once, the result was a jumble of unintelligible marks on the tape. There was a notable characteristic about the spark gap transmitter. On reception, each signal sounded just a little bit different than the rest. This signal characteristic was usually determined by electrode gap spacings, electrode shapes, and power levels inherent to each transmitter. With a little practice, one could attach an identity to the transmitting station based on the sound in the headphones. From a security viewpoint, this was not good for any navy, as a ship could eventually be identified by the tone of its transmitted signal. On the other hand, this signal trait was a blessing, otherwise, there would have been no hope of communication as 'spark' produced signals were extremely wide.
    [Show full text]
  • Sir J. C. Bose's Diode Detector Received Marconi's
    Sir J. C. Bose’s Diode Detector Received Marconi’s First Transatlantic Wireless Signal of December 1901 (The “Italian Navy Coherer” Scandal Revisited) PROBIR K. BONDYOPADHYAY, SENIOR MEMBER, IEEE The true origin of the “mercury coherer with a telephone” receiver that was used by G. Marconi to receive the first transat- lantic wireless signal on December 12, 1901, has been investigated and determined. Incontrovertible evidence is presented to show that this novel wireless detection device was invented by Sir. J. C. Bose of Presidency College, Calcutta, India. His epoch- making work was communicated by Lord Rayleigh, F.R.S., to the Royal Society, London, U.K., on March 6, 1899, and read at the Royal Society Meeting of Great Britain on April 27, 1899. Soon after, it was published in the Proceedings of the Royal Society. Twenty-one months after that disclosure (in February 1901, as the records indicate), Lieutenant L. Solari of the Royal Italian Navy, a childhood friend of G. Marconi’s, experimented with this detector device and presented a trivially modified version to Marconi, who then applied for a British patent on the device. Surrounded by a scandal, this detection device, actually a semiconductor diode, is known to the outside world as the “Italian Navy Coherer.” This scandal, first brought to light by Prof. A. Banti of Italy, has been critically analyzed and expertly presented in a time sequence of events by British historian V. J. Phillips but without discovering the true origin of the novel detector. In this paper, the scandal is revisited and the mystery of the device’s true origin is solved, thus correcting the century-old misinformation on an epoch-making chapter in the history of semiconductor devices.
    [Show full text]
  • Finite Element Modeling of the Effect of Creep Damage on a Magnetic
    FINITE ELEMENT MODELING OF THE EFFECT OF CREEP DAMAGE ON A MAGNETIC DETECTOR SIGNAL FOR SEAM-WELDED STEEL PIPES M.l Sablik Southwest Research Institute P.O. Drawer 28510 San Antonio, Tx 78228-0510 D.C. Jiles Center for NDE Iowa State University Ames, IA 50011 M.R. Govindaraju Magnetica, Inc. P.O. Box 1521 Ames, IA 50014 INTRODUCTION Creep damage is the result of slow plastic flow of metal under stress and at high temperature, typically about 50% of the absolute melting temperature. If there is enough creep damage, the end result can be sudden, catastrophic failure. Lately, creep has become a serious problem in the petrochemical industry and in fossil fuel power plants, where alloy steel pipes are subjected to stress and high temperature for long periods of time. The problem is particularly acute in seam-welded pipe because the creep damage develops first inside the pipe wall and doesn't appear at the wall surface until the pipe is almost ready to fail Thus, it is possible to have failure almost without warning. This dangerous situation can occur with seam-welded pipe because the cross-section of the weld is shaped like two trapezoids with the larger bases of the trapezoids on the inside and outside wall of the pipe and with the smaller trapezoid bases meeting in the interior to form an interior cusp. The stress concentrates at the cusp, and it is at the cusp where creep damage begins. The creep damage then works its way toward the inside and outside pipe surfaces. [1] A standard technique for detecting creep damage is replication [2], which involves making a wax or epoxy replica of the pipe surface and subsequent microscopic analysis.
    [Show full text]
  • Electronic Home Music Reproducing Equipment
    Electronic Home Music Reproducing Equipment Daniel R von Recklinghausen Copyright © 1977 by the Audio Engineering Society. Reprinted from the Journal of the Audio Engineering Society, 1977 October/November, pages 759...771. This material is posted here with permission of the AES. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the AES by contacting the Managing Editor, William McQuaid., [email protected]. By choosing to view this document, you agree to all provisions of the copyright laws protecting it. John G. (Jay) McKnight, Chair AES Historical Committee 2005 Nov 07 Electronic Home Music Reproducing Equipment DANIEL R. VON RECKLINGHAUSEN Arlington, MA The search for amplification and control of recorded and transmitted music over the last 100 years has progressed from mechanical amplifiers to tube amplifiers to solid-state equipment. The AM radio, the record player, the FM receiver, and the tape recorder have supplemented the acoustical phonograph and the telephone. An incomplete summary of important developments in the past is presented along with challenges for the future. Home music reproduction began when Bell invented the tromechanical repeater caused it to be used for 20 years telephone in 1876 and Edison invented the phonograph in more as a hearing-aid amplifier [5, pp. 64-69]. 1877. Instruments were manufactured soon thereafter and C.A. Parsons of London, England, inventor of the leased or sold to the public. Yet the listener had very little Auxetophone, marketed in 1907 a phonograph where the control over the reproduction and the volume of sound, the playback stylus vibration caused a valve to modulate a tone quality being predetermined by the manufacturer of stream of compressed air which was fed to a reproducing the phonograph and record or by the telephone company horn [6].
    [Show full text]
  • Birth of the Valve.Indd 68 25/01/2019 08:21 Attention to the Problem of Developing an Eff Cient Receiving Detector
    Feature by Dr Bruce Taylor HB9ANY ● E-mail: [email protected] Birth of the Thermionic Valve n the archives of Marconi’s Dr Bruce Taylor HB9ANY relates how chance, ingenuity Wireless Telegraph Company and confl ict created the technology that dominated radio for November 1904, there is a handwritten letter that communication for half a century. concludes: “I have not mentioned Ithis to anyone yet, as it may become useful”. The letter is signed by the English scientist John Ambrose Fleming and it describes how he had found a method of detecting oscillatory electrical currents in an antenna using a thermionic valve. “It may become useful” was perhaps the understatement of the century! While the saga of the thermionic valve had a large cast, the two principal roles were initially played by Fleming and the American experimenter Lee de Forest. The characters of these two men could hardly have been more different. De Forest was an enterprising inventor but a f amboyant showman unashamedly motivated by a desire for fame, fortune and a luxurious life style. He was lucky in his discoveries, but not in his private life or his somewhat unethical business practices, and he died in 1961 without achieving the f nancial success of which he dreamed. Fleming, on the other hand, was the careful archetypal physicist, methodical in his investigations and A 1915 advertisement by Elmer Cunningham explains that, unlike the de Forest Audion, his AudioTron motivated to earn the esteem and can be bought alone. recognition of his peers for advancing scientif c knowledge. He achieved his aim, he patented the device as a means for The Fleming Diode and was knighted in 1929, but he wasn’t controlling mains voltage but made no In 1899, Fleming had been appointed interested in vigorously exploiting his mention of its rectifying properties, for he scientif c advisor to Marconi and became discoveries and left Marconi and others was promoting DC rather than AC power responsible for the design of part of the to prof t from their commercialisation.
    [Show full text]
  • A Magnetic Flux Leakage NDE System for CANDUR Feeder Pipes
    A Magnetic Flux Leakage NDE System for CANDU R Feeder Pipes by Thomas Don Mak A thesis submitted to the Department of Physics, Engineering Physics & Astronomy in conformity with the requirements for the degree of Master of Applied Science Queen’s University Kingston, Ontario, Canada March 2010 Copyright c Thomas Don Mak, 2010 Library and Archives Bibliothèque et Canada Archives Canada Published Heritage Direction du Branch Patrimoine de l’édition 395 Wellington Street 395, rue Wellington Ottawa ON K1A 0N4 Ottawa ON K1A 0N4 Canada Canada Your file Votre référence ISBN: 978-0-494-65131-5 Our file Notre référence ISBN: 978-0-494-65131-5 NOTICE: AVIS: The author has granted a non- L’auteur a accordé une licence non exclusive exclusive license allowing Library and permettant à la Bibliothèque et Archives Archives Canada to reproduce, Canada de reproduire, publier, archiver, publish, archive, preserve, conserve, sauvegarder, conserver, transmettre au public communicate to the public by par télécommunication ou par l’Internet, prêter, telecommunication or on the Internet, distribuer et vendre des thèses partout dans le loan, distribute and sell theses monde, à des fins commerciales ou autres, sur worldwide, for commercial or non- support microforme, papier, électronique et/ou commercial purposes, in microform, autres formats. paper, electronic and/or any other formats. The author retains copyright L’auteur conserve la propriété du droit d’auteur ownership and moral rights in this et des droits moraux qui protège cette thèse. Ni thesis. Neither the thesis nor la thèse ni des extraits substantiels de celle-ci substantial extracts from it may be ne doivent être imprimés ou autrement printed or otherwise reproduced reproduits sans son autorisation.
    [Show full text]
  • JI ~U 1U 112 ~A\. IL JULY-AUG 1984
    Ctil!~ ()fficlar JI ~u 1u 112 ~A\. IL JULY-AUG 1984 1930 "AMERICAN" MICROPHONE I .... CALIFORNIA HISTORICAL RADIO SOCIETY PRESIDENT: NORMAN BERGE SECRETARY: BOB CROCKETT TREASURER: JOHN ECKLAND EDITOR: HERB BRA~S PHOTOGRAPHY: GEORGE DURFEY CONTENTS SPARK TRANSMITTERS .... ..... ....... .. .... ··· .. ················ · · l EARLY DETECTORS ......................... ···.················· ·· 3 TRANSMITTER ............................... · .. · ·········· · ··· ··· 6 BUSCO CRYSTAL SET . ........................ · ... · · · · · · · · · · · · · · · · · 6 CRYSTAL DETECTORS ............................................ THE GEIGER COUNTER ..... ........ .... ... ... ... ············ ··· 8 WUNDERLICH DETECTOR TUBES .. .................... .. · · · · · · · · · · · · · · 0 THE FRIENDLY B.E.A.R .......... ..... ........ .. ............ .• . J.:2 VOLTAG E MEASUREMENTS ... .... .................................. 1 5 USI NG DISCRETION IN ALIGNMENT . ............................. ...• ADVERTISEMENTS ........................................... •. •.22 THE SOCIETY 1be California Historical Radio Society is a non-profit corporation chartered in 1974 to pranote the preservation of early rad i o equipment and radio broadcasting. CHRS provides a medium for members to exchange infor­ mation on the history of radio with emphas i s on areas such as collecting, cataloging and restoration of equipment , l i terature . and progr ams. Regu ax swap meets are scheduled four times a year . For further information. wr i te the California Historical Radio Society, P. O.
    [Show full text]
  • Effectiveness of Magnetic Detectors in Alarm Systems
    Tomasz PRAUZNER Jan Dlugosz University in Czestochowa, Institute of Technical Education and Safety Effectiveness of magnetic detectors in alarm systems Abstract. The paper presents results of experiments and of modelling magnetic field by means of the finite element method (FEM). The study was performed on a magnetic detector K-1 manufactured by Satel, and the results of modelling were subsequently compared to those published by the manufacturer. The study also comprises the influence of changes in selected constructional parameters of the magnet on the detecting range. The finite element method is widely applied for the description of inductive phenomena since it is well suited for the analysis of complex electrical systems and their components. Streszczenie. W artykule przedstawiono wyniki badań oraz modelowania pola magnetycznego za pomocą metody elementów skończonych. Modelowaniu poddano czujkę magnetyczną K-1 firmy Satel, wyniki porównano z wynikami udostępnionymi przez producenta. W pracy zbadano również wpływ zmiany wybranych parametrów konstrukcyjnych magnesu na zasięg detekcji czujki. Metoda elementów skończonych jest powszechnie znaną i wykorzystywaną w ocenie zjawisk indukcyjnych, umożliwiającą analizę pracy skomplikowanych elementów i układów elektrycznych. (Skuteczność działania czujek magnetycznych w układach alarmowych) Keywords: magnetic detector, simulation, modelling, FEM Słowa kluczowe: czujka, symulacja, modelowanie, MES doi:10.12915/pe.2014.12.68 Introduction the contacts of the reed switch. The construction of some The study is based on an application of FEM modelling switches, such as small-size switches, or multiple-switch in a 2-D space. This method makes it possible to divide the detectors requires that the shift dy has to be minimised, region under scrutiny into triangles and to set the boundary which affects the operating characteristics of the reed conditions.
    [Show full text]
  • HISTORY of WIRELESS MUSEUM Bits of Ihelfj5 History
    OF GRAY HISTORY OF WIRELESS MUSEUM Bits of IHElfJ5 History BY G. J. GRAY FOREWORD This book was written primarily to supply the visitor to The Gray History of Wireless Museum with pictures and descriptions of items in the Museum. It is hoped that my many friends who are historians and collectors of antique radio equipment will find it useful. The original idea came from a suggest­ ion to do some historical sketches for The Greater Cincinnati Amateur Radio Association "Mike & Key" magazine. Encouragement has come from many visitors to the Museum and from fellow members of The Antique Wireless Association. Sources of material have been early radio magazines, books, catalogues, inter­ views and over fifty years in the radio field. G.J.Gray January 1969 First Edition Oopyright 1969 by GeJ.Gray Th1s book 1s affect10nately ded1cated te my w1fe Ruth BITS OF WIRELESS HISTORY 1-Bergman Direct Current Meter 2-The Condenser is Born 3-1906 Clark Wireless Receiver 4-The Electrolytic Detector 5-Hassie Oscillaphone Detector 6-de Forest Gas Flame Detector 7-de Forest Spherical Audion 8-de Forest RJ-5 Audion Detector 9-Audiotron Detector Panel 10-Audiotron Tube 11-Marconi-de Forest Tube Litigation 12-de Forest Interpanel Receiver 13-Marconi Magnetic Detector 14-The Boston Transmitting Key 15-Electro Importing Company 16-E.I. Co. Two Slide Tuning Coil E.I. Co. 10¢ Galena Detector 17-A.C.Gilbert One Tube Receiver 18-1915 Loose Coupler Receiver 19-William B. Duck Catalogue 20-Duck Arlington Loose Coupler 21-Ferron Crystal Detector Stand 22-Blitzen Receiving Tuner Magnavox Horn 23-Phonograph Horn With Microphone Burns Radio Speaker 24-Hurdock Variable Condenser Remler Variable Condenser 25-Aeriola Jr.
    [Show full text]
  • The Genesis of the Thermionic Valve
    1 THE GENESIS OF THE THERMIONIC VALVE A lecture given to the Institution of Electrical Engineers in 1954 on the fiftieth anniversary of the invention of the thermionic valve. By Professor G. W. O. HOWE, D.Sc., LL.D., Member Prof. Howe is Emeritus Professor of Electrical Engineering, University of Glasgow. Lecture delivered before The Institution 16th November, 1954 I FEEL honoured in being invited to give the opening lecture at this celebration of the jubilee of the invention of the thermionic valve. I feel that I cannot begin the lecture in a more appropriate manner than by trying to give you a picture of the inventor himself, for I realize that to many of the younger members of The Institution he is little more than a name. John Ambrose Fleming was born at Lancaster in 1849, but when he was five years old the family moved to North London. His father, a clergyman and a doctor of divinity, was born at Kelso, in Scotland, of an old Scottish family of Flemish origin, as the name shows. At the age of 14 young John was sent to University College School , a day school conducted at that time in a wing of University College in Gower Street, where he was later to be Professor of Electrical Engineering. Although his interests were mainly in machinery and scientific matters, he had to work hard at Latin and Greek in order to pass the London Matriculation examination, which he did when he was 16. He was then entered as a science student at the College.
    [Show full text]