Alcohol Lamp Laboratory Hot Plate Electric Gas Lighter Safety Spark

Total Page:16

File Type:pdf, Size:1020Kb

Alcohol Lamp Laboratory Hot Plate Electric Gas Lighter Safety Spark Bu Burners Alcohol Lamp Laboratory Hot Plate Safe and durable lamp with compact design Gas-operated hot plate provides an efficient source Alcohol lamp is ideal of infrared heat for laboratories where ■ Solid-state push- there is no gas source. button auto ignition It is made of nickel- plated brass. Optional ■ Heat output is fully two-way lamp stand adjustable available. The height ■ Refill with standard of the lamp stand is butane fuel 4" or 5" (10 or 12 cm), depending on This compact ceramic orientation of stand. heating burner features an infrared heat source What’s included: that can be adjusted Hot plate 36138-00 shown with snuffer cap and one from ambient to 2012°F extra wick (order (1100°C). beaker stand 36138-02 additional wicks below). Catalog number Description H x dia Price Lamp 36300-20 shown with two-way stand 36300-26 T-36138-00 Laboratory hot plate 3" x 6" (7.6 x 15.2 cm) T-36138-02 Beaker stand, supports a 1-L beaker Catalog number Description H x dia Price T-36138-90 Butane fuel canisters. Case of 12 T-36300-20 Alcohol lamp 31⁄2" x 4" (9 x 10 cm) T-36300-26 Two-way lamp stand T-36300-22 Replacement wicks. Pack of 12 Test Tube Clamp Safety Spark Lighter Spring action, self-closing rectangular jaws 08048-60 Sure, safe ignition for your (test tube not included) bunsen burner Use this well-constructed, safety spark lighter for all your burner ignition needs. Special spark hood Catalog number Length Material Qty/pk Price/pk protects the flint. Gas pocket forms T-08048-60 5" (12.7 cm) Brass 5 beneath the hood, ensuring instant lighting. What’s included: five flint renewals (order more separately below). Wire Gauze Spark lighter 36136-50 Stainless steel mesh for long life and safety (gas burner not included) ■ Withstands temperatures up Catalog number Description Price to 1472°F (800°C) T-36136-50 Safety spark lighter ■ Edges are reinforced T-36136-55 Single flint renewals. Pack of 5 to prevent fraying 36300-40 36300-42 36300-44 Electric Gas Lighter Catalog number L x W Qty/pk Price/pk T-36300-40 4" x 4" (10.2 x 10.2 cm) T-36300-42 5" x 5" (12.7 x 12.7 cm) 10 Lighter provides safe lighting T-36300-44 6" x 6" (15.2 x 15.2 cm) without an open flame This hazard-proof lighter eliminates the difficulty of a striking flint. It features a comfortable plastic pistol grip and has a push-button trigger Tripod Burner Stands that creates a 20 Kv electrical spark. These single-ring tripod stands feature a cast-iron top and mild steel legs. The top finished in baked hammertone and the legs are plated and removable. 36310-45 36300-49 Catalog number Description Length Price T-36310-45 Electric gas lighter 107⁄16" (26.5 cm) Catalog number H x dia Price T-36300-46 6" x 3" (15.2 x 7.6 cm) T-36300-49 9" x 4" (22.9 x 10.2 cm) 238 US Toll-free: 800-323-4340 • Outside the US: 1-847-549-7600 • www.coleparmer.com Canada 800-363-5900 • India 91-22-6716-2222 • UK 0500-345-300.
Recommended publications
  • T&S Quality Pet-Care Plumbing Products
    JA Pet-CarePre-Rinse Plumbing Units Products T&S Quality Pet-Care Plumbing Products – Our Pedigree is Your Quality Assurance RINSE UNITS Wash and Rinse Products Replacement Parts Model # Description EB-10K Repair Kit 013539-45 Replacement Hose PG-35AV Aluminum Valve PG-4DREV Lighweight Aluminum Spray Unit PG-35AV-CH Coiled Hose and Spray Valve • 4” (102 mm) deck-mount faucet (B-0326-LN) • Lightweight aluminum handle with rubber grip and hold down clip • ½” NPT female eccentric flanged inlets (00AA) • ¼” NPT male inlet • Vacuum breaker outlet • Coiled polyurethane hose with maximum stretching length of 9 ft. • 9 ft. coiled hose and aluminum spray valve • Lightweight spray valve for easy, all-day use PG-35AV-CH01 Same as PG-35AV-CH except with ¾” female garden • Wall hook hose inlet (PG-0001) PG-35AV-CH02 Same as PG-35AV-CH except with ³/8” NPT female PG-1DREV Same as PG-4DREV except single hole inlet (PG-0002) single temperature deck mount faucet with vacuum PG-35AV-CH03 Same as PG-35AV-CH except with ½” NPT female breaker inlet (PG-0003) PG-8DREV Same as PG-4DREV except with 8” centers PG-35AV-CH05 Same as PG-35AV-CH except with ¾” x 14 female inlet (052A) PG-8WSAV-08 Lighweight Aluminum Spray Unit PG-8WREV Lighweight Aluminum Spray Unit • 8” (203 mm) wall-mount faucet • 8” (203 mm) wall-mount faucet • ½” NPT female eccentric flanged inlets (00AA) • ½” NPT female eccentric flanged inlets (00AA) • Vacuum breaker • Vacuum breaker outlet • 9 ft. coiled hose and aluminum spray valve • 9 ft. coiled hose and aluminum spray valve • Swivel adapter • Lightweight spray valve for easy, all-day use • Add-on faucet with 8” swing nozzle and stream regulator outlet • Wall hook • Lightweight spray valve for easy, all-day use • Wall hook PG-1WSAV-06 Same as PG-8WSAV-08 except single hole wall-mount faucet with vacuum breaker, 9 ft.
    [Show full text]
  • Steam Distillation Manual NC-13223
    DIRECTIONS FOR USING 24/40 DISTILLATION APPARATUS, NC-11663 WARNING: For use by adults with knowledge of general laboratory safety procedures. Always wear proper eye and hand protection when handling glass labware and heat! SAFETY FIRST Other items needed (not supplied in kit)... This apparatus uses a heat source (optionally • Heat source such as alcohol, Bunsen, or gas available) to heat the contents of the Boiling Flask. burner. Use caution when handling to prevent burns! • Two pieces of flexible tubing to connect a water Protect eyes and skin from hot gasses and broken supply to the Graham condenser. or chipped glassware. Be sure all components are properly set up ASSEMBLY (Refer to Figure 1). This apparatus is an open Assemble the Lab Support Stand by attaching system so pressure is relieved at the drip end of the support rod to the metal base. Then open wide the condenser. (Make sure you leave a small gap the jaws of the clamp and loosely attach it to the between the drip tip and the receiving flask.) support rod. Material may crystallize in the condenser, which, over time, could block steam causing a dangerous Assemble the tripod base by screwing the three build up of pressure and possible explosion. When legs into the iron ring. Place the Wire Gauze finished with distillation, allow system to cool, then Square and the Boiling Flask on top of the iron drain the condenser of cooling water. Always work ring. with clean glassware. Next, place the Kjeldahl Distilling Column in the Use caution when handling glassware, top of the Boiling Flask, and attach the Graham especially when cleaning.
    [Show full text]
  • Laboratory Equipment Used in Filtration
    KNOW YOUR LAB EQUIPMENTS Test tube A test tube, also known as a sample tube, is a common piece of laboratory glassware consisting of a finger-like length of glass or clear plastic tubing, open at the top and closed at the bottom. Beakers Beakers are used as containers. They are available in a variety of sizes. Although they often possess volume markings, these are only rough estimates of the liquid volume. The markings are not necessarily accurate. Erlenmeyer flask Erlenmeyer flasks are often used as reaction vessels, particularly in titrations. As with beakers, the volume markings should not be considered accurate. Volumetric flask Volumetric flasks are used to measure and store solutions with a high degree of accuracy. These flasks generally possess a marking near the top that indicates the level at which the volume of the liquid is equal to the volume written on the outside of the flask. These devices are often used when solutions containing dissolved solids of known concentration are needed. Graduated cylinder Graduated cylinders are used to transfer liquids with a moderate degree of accuracy. Pipette Pipettes are used for transferring liquids with a fixed volume and quantity of liquid must be known to a high degree of accuracy. Graduated pipette These Pipettes are calibrated in the factory to release the desired quantity of liquid. Disposable pipette Disposable transfer. These Pipettes are made of plastic and are useful for transferring liquids dropwise. Burette Burettes are devices used typically in analytical, quantitative chemistry applications for measuring liquid solution. Differing from a pipette since the sample quantity delivered is changeable, graduated Burettes are used heavily in titration experiments.
    [Show full text]
  • Download Author Version (PDF)
    Chemistry Education Research and Practice Accepted Manuscript This is an Accepted Manuscript, which has been through the Royal Society of Chemistry peer review process and has been accepted for publication. Accepted Manuscripts are published online shortly after acceptance, before technical editing, formatting and proof reading. Using this free service, authors can make their results available to the community, in citable form, before we publish the edited article. We will replace this Accepted Manuscript with the edited and formatted Advance Article as soon as it is available. You can find more information about Accepted Manuscripts in the Information for Authors. Please note that technical editing may introduce minor changes to the text and/or graphics, which may alter content. The journal’s standard Terms & Conditions and the Ethical guidelines still apply. In no event shall the Royal Society of Chemistry be held responsible for any errors or omissions in this Accepted Manuscript or any consequences arising from the use of any information it contains. www.rsc.org/cerp Page 1 of 26 Chemistry Education Research and Practice 1 2 3 4 Video episodes and action cameras in the undergraduate chemistry laboratory: Eliciting 5 6 student perceptions of meaningful learning 7 Kelli R. Galloway and Stacey Lowery Bretz* 8 Department of Chemistry & Biochemistry, Miami University, Oxford, OH, 45056, United States 9 10 Abstract 11 A series of quantitative studies investigated undergraduate students’ perceptions of their cognitive and 12 affective learning in the undergraduate chemistry laboratory. To explore these quantitative findings, a 13 qualitative research protocol was developed to characterize student learning in the undergraduate Manuscript 14 15 chemistry laboratory.
    [Show full text]
  • First Aid & Safety Product and Services Guide
    WE DELIVER. WE STOCK. WE MAINTAIN. WE TRAIN. WE MAINTAIN. WE STOCK. WE DELIVER. VISIT CINTAS.COM OR CALL OR 877.973.2811 CINTAS.COM VISIT FIRST AID Cintas First Aid & Safety Product and Services Guide Services and Product Safety & Aid First Cintas May 2021 May Product and Services Guide First Aid & Safety TRAINING EYEWASH AEDs WATERBREAK® SAFETY & PPE FIRST AID We've got you covered Providing first aid & safety supplies to your employees is important to the success of your business. That’s why over 250,000 businesses choose Cintas First Aid & Safety. We are a single source provider for your first aid, safety, training, AED, eyewash and employee hydration needs. Our services can help you keep your employees safe, productive and on the job. Cintas helps you manage the details with personal, van-delivered, onsite service so that the products you've selected are always stocked. We know that being in business is hard and staying in business is even harder. With Cintas, you can focus on what you are good at and let our trained service professionals restock your first aid supplies, maintain your safety and personal protective equipment (PPE) inventory, check your AEDs, offer training and compliance courses of your choice, service your eyewash stations and provide clean, affordable filtered water. Our goal is to help you and your employees get Ready for the Workday®. Contents First Aid .......................................................... 2 Eye relief ...........................................................38 Apparel ............................................................86
    [Show full text]
  • Laboratory Equipment AP
    \ \\ , f ?7-\ Watch glass 1 Crucible and cover Evaporating dish Pneumatlo trough Beaker Safety goggles Florence Wide-mouth0 Plastic wash Dropper Funnel flask collecting bottle pipet Edenmeyer Rubber stoppers bottle flask € ....... ">. ÿ ,, Glass rod with niohrome wire Scoopula (for flame re,sting) CruoiNe tongs Rubber ubing '1 ,v .... Test-tube brush square Wire gau ÿ "\ file Burner " Tripod Florence flask: glass; common sizes are 125 mL, 250 mL, 500 .d Beaker: glass or plastic; common sizes are 50 mL, mL; maybe heated; used in making and for storing solutions. 100 mL, 250 mL, 400 mL; glass beakers maybe heated. oÿ Buret: glass; common sizes are 25 mL and 50 mL; used to Forceps: metal; used to hold or pick up small objects. Funnel: glass or plastic; common size holds 12.5-cm diameter measure volumes of solutions in titrafions. Ceramic square: used under hot apparatus or glassware. filter paper. Gas burner: constructed of metal; connected to a gas supply Clamps" the following types of clamps may be fastened to with rubber tubing; used to heat chemicals (dry or in solution) support apparatus: buret/test-tube clamp, clamp holder, double buret clamp, ring clamp, 3-pronged jaw clamp. in beakers, test tubes, and crucibles. Gas collecting tube: glass; marked in mL intervals; used to 3: Clay triangle: wire frame with porcelain supports; used to o} support a crucible. measure gas volumes. Glass rod with nichrome wire: used in flame tests. Condenser: glass; used in distillation procedures. Q. Crucible and cover: porcelain; used to heat small amounts of Graduated cylinder: glass or plastic; common sizes are 10 mL, 50 mL, 100 mL; used to measure approximate volumes; must solid substances at high temperatures.
    [Show full text]
  • Visco Handbook THEORY and APPLICATION of VISCOMETRY with GLASS CAPILLARY VISCOMETERS Welcome to SI Analytics!
    Visco handbook THEORY AND APPLICATION OF VISCOMETRY WITH GLASS CAPILLARY VISCOMETERS Welcome to SI Analytics! We express our core competence, namely the production of analytical instruments, with our company name SI Analytics. SI also stands for the main products of our company: sensors and instruments. As part of the history of SCHOTT® AG, SI Analytics has nearly 80 years experience in glass technology and in the development of analytical equipment. As always, our products are manufactured in Mainz with a high level of innovation and quality. Our electrodes, titrators and capillary viscometers will continue to be the right tools in any location where expertise in analytical measurement technology is required. In 2011 SI Analytics became part of the listed company Xylem Inc., headquartered in Rye Brook / N.Y., USA. Xylem is a leading international provider of water solutions. We are pleased to introduce you to the Visco Handbook! It replaces the previous brochure "Theory and Practice of Capillary Viscometry". This has been updated, redesigned and restructured. The information content of some areas such as polymer analysis was increased and specially themed areas such as hydrodynamic principles were moved into their own appendices so as not to deter the reader by too much theory. The focus was placed on the practical and general information needed by each user of capillary viscometry. Both laboratory experiences and policies of the relevant standards are considered here. We thus hope to provide you with a faithful companion for everyday laboratory work, one that you can use profitably. We of SI Analytics are pleased to work with you successfully in the future.
    [Show full text]
  • Tests of Instruments for the Determination, Indication, Or Recording of the Specific Gravities of Gases
    U. S. DEPARTMENT OF COMMERCE W. AVERELL HARRIMAN, Secretary NATIONAL BUREAU OF STANDARDS E. U. CONDON, Director NATIONAL BUREAU OF STANDARDS MISCELLANEOUS PUBLICATION M177 TESTS OF INSTRUMENTS FOR THE DETERMINATION, INDICATION, OR RECORDING OF THE SPECIFIC GRAVITIES OF GASES By FRANCIS A. SMITH, JOHN H. EISEMAN, AND E. CARROLL CREITZ Issued January 20, 1947 UNITED STATES GOVERNMENT PRINTING OFFICE WASHINGTON : 1947 For sale by the Superintendent of Documents, U. S. Government Printing Office Washington 25, D. C. - Price $1.00 PREFACE At the request of the American Society for Testing Materials, a critical study was made of the commercial instruments for the deter- mination of the specific gravities of gases. Eleven different instru- ments were studied with the use of 15 test gases of known specific gravities. Determinations were made of the accuracy and reproduci- bility, of the effects of changes of temperature, relative humidity and water content of the surrounding air, and of sources of error and applicable corrections. It is believed that the results herein presented will be of considerable value to those requiring accurate data on the specific gravities of gases. E. U. Condon, Director. ii TESTS OF INSTRUMENTS FOR THE DETERMINATION, INDICATION, OR RECORDING OF THE SPECIFIC GRAVITIES OF GASES By Francis A. Smith, John H. Eiseman, and E. Carroll Creitz ABSTRACT At the request of the American Society for Testing Materials, the National Bureau of Standards completed in 1941 a critical study of instruments available to industry for the determination, indication, or recording of the specific gravities of gases. Instruments were submitted for test by all interested manufacturers.
    [Show full text]
  • Theory and Praxis of Capillary Viscometry
    Theory and Praxis of Capillary Viscometry - An Introduction – Authors: Prof. Dr.-Ing. habil. Jürgen Wilke Hochschule Anhalt Food and biotechnology (Process and environmental Technology Faculty) Dr.-Ing. Holger Kryk Magdeburg Dr.-Ing. Jutta Hartmann Rheinfelden Dieter Wagner SCHOTT-GERÄTE GmbH Viscometry development dept. Table of contents Page 1 Viscosity – Rheology ................................................... 2 2 Basics of capillary viscometry ................................. 5 2.1 Measurement principle ................................................. 5 2.2 Designs of glass capillary viscometers ......................... 5 3 Measurement of flow time .......................................... 7 3.1 Manual time measurement ........................................... 7 3.2 Automatic time measurement ....................................... 7 3.2.1 Tasks and particularities ............................................... 7 3.2.2 Detection of the meniscus passage ............................. 7 4 Working equation of glass capillary viscometers ...................................... 9 4.1 Procedure for viscosity determination .......................... 9 4.1.1 Neglect of HC correction .............................................. 9 4.1.2 Calculation of HC correction resp. use of given table values ............................................ 10 4.1.3 Experimental determination of the individual HC correction ............................................. 12 5 Calibration ......................................................................
    [Show full text]
  • Fisher Science Education 2021 Product Catalog Featured Suppliers
    Lab Consumables Fisher Science Education 2021 Product Catalog Featured Suppliers Visit fisheredu.com/featuredsuppliers to learn more about these suppliers and their products. Helpful Icons Guarantee New product If you’re not 100% satisfied with your purchase, contact our customer service team within 30 days of your invoice date and we’ll either exchange, repair, or replace the product, or Must be shipped by truck for regulatory give you a credit for the full purchase price. Call us toll-free reasons for a return authorization number. Special order items, furniture, and closeouts cannot be exchanged or credited. Meets Americans with Disabilities Act Phone: 1-800-955-1177 • 7 a.m. to 5:30 p.m. requirements Central Time, Monday through Friday Fax: 1-800-955-0740 • 24 hours a day, 7 days a week Protects against splashes from Email: [email protected] hazardous chemicals or potentially infectious materials Website: fisheredu.com Address: Fisher Science Education 4500 Turnberry Drive Applicable for remote learning Hanover Park, IL 60133 For international orders, see page 110. All prices are subject to change. Connect with Us on Social Media fisheredu.com/facebook twitter.com/fishersciedu pinterest.com/fishersciedu Lab Consumables Preparing today’s students to be the innovators of tomorrow isn’t always easy, but finding the right teaching tools can be. From basic lab supplies to state-of- the-art classroom technology, the Fisher Science Education team has everything you need to create a 21st century STEM learning environment. Visit fisheredu.com to get started. Want to customize aspects of your curriculum? Explore custom kits to meet the unique demands of your classroom.
    [Show full text]
  • THE STOICHIOMETRY of ANCIENT METALLURGY Materials: Ring
    THE STOICHIOMETRY OF ANCIENT METALLURGY Adapted by: MIDN 1/C Justin Dion Materials: Ring stand (2), tripod stand, clay triangle, small porcelain crucible with lid, Bunsen burner (2), malachite chips, granular (“fish bowl”) charcoal, crucible tongs, forceps, striker, weighing boat Ref: Yee, Gordon T.; Johnson, Chris E. J. Chem. Educ. 2004, 81, 1777-1779 Purpose: The purposes of this experiment are: (1) To prepare elemental copper through the techniques used by Stone Age men circa 3000 B.C.E; and (2) to trace the stoichiometry of a 2 step reaction through percent yield determinations at each step. Learning Objectives: 1. Master the proper and most effective use of a Bunsen burner 2. Understand basic stoichiometry and be able to calculate the expected and % yield of each step of a reaction 3. Recognize and appreciate the historical aspects of metallurgy and apply them to a contemporary laboratory environment Pre-lab: Complete the pre-lab questions before lab. Discussion1: Technological advancements were for thousands of years the outcome of accidents. The greatest discoveries of the Stone Age period were driven not by a desire for scientific data, but rather by the activities that were part of everyday life for the ancient man. Stone Age men were drawn to naturally occurring materials that were aesthetically pleasing. They searched for strong, durable materials that could be used as tools. They also searched for materials that could be used as jewelry or as works of art. Around 3000 B.C.E, Stone Age men were drawn towards malachite, a bright green mineral that was abundant in the cliffs and hillsides that surrounded them.
    [Show full text]
  • Outdoor Microalgae Production
    Outdoor microalgae production Jeroen H. de Vree Thesis committee Promotor Prof. Dr R. H. Wijffels Professor of Bioprocess Engineering Group Wageningen University Co-promotors Dr R. Bosma AlgaePARC operational manager, Bioprocess Engineering Group Wageningen University Dr M. J. Barbosa Associate Professor, Bioprocess Engineering Group Wageningen University Other members Prof. Dr. F.G. Acien Fernandez, Almeria University, Spain Dr. B.G. Temmink, Wageningen University Dr. L. Rodolfi, Florence University, Italy Prof. Dr. E.J. van Henten, Wageningen University This research was conducted under the auspices of the Graduate School VLAG (Advanced studies in Food Technology, Agrobiotechnology, Nutrition and Health Sciences). Outdoor production of microalgae Jeroen Hendrik de Vree Thesis submitted in fulfilment of the requirements for the degree of doctor at Wageningen University by the authority of the Rector Magnificus Prof. Dr A.P.J. Mol in the presence of the Thesis Committee appointed by the Academic Board to be defended in public on Friday 14 October 2016 at 4 p.m. in the Aula. Jeroen H. de Vree Outdoor production of microalgae, 177 pages. PhD thesis, Wageningen University, Wageningen, NL (2016) With references, with summary in English ISBN 978-94-6257-878-4 DOI 10.18174/387236 Table of Contents Chapter 1 Introduction ................................................................................................................................ 9 Chapter 2 ....................................................................................................................................
    [Show full text]