NQ-A4060, NQ-A4120, NQ-A4300 4 Channel Audio Power Amplifiers
Total Page:16
File Type:pdf, Size:1020Kb
4-Channel Audio Power Amplifiers Configuration Manual NQ-A4060, NQ-A4120, NQ-A4300 2019 Bogen Communications, Inc. All rights reserved. 740-00099D 191101 Contents List of Figures ............................................................................... v List of Tables .............................................................................. vii Configuring the Four-Channel Audio Power Amplifiers 1-1 1 Using the Dashboard ..............................................................................3 2 Updating Firmware ..................................................................................4 3 Setting Network Tab Parameters .......................................................6 4 Setting Configuration Tab Parameters ............................................8 5 Accessing Log Files ............................................................................... 10 6 Setting DSP Parameters ...................................................................... 13 6.1 Setting the Channel Level .................................................. 15 6.2 Signal LED, Clip LED, and VU Meter .............................. 15 6.3 Muting a Channel ................................................................. 16 6.4 Adjusting Volume Levels ................................................... 16 6.5 Adjusting Compression Settings .................................... 16 6.6 Adjusting the Graphic Equalizer ..................................... 18 6.7 Setting High/Low Pass Parameters ................................ 20 6.8 Adjusting the Limiter ........................................................... 23 6.9 Adjusting Noise Gate Settings ......................................... 24 6.10 Adjusting Parametric Equalizer Settings ...................... 25 6.11 Adjusting Router Settings ................................................. 27 6.12 Settings ..................................................................................... 28 6.13 Signal Present ........................................................................ 30 6.14 Status ......................................................................................... 32 i ii List of Figures Figure 1, Nyquist Appliance Login . 2 Figure 2, Matrix Mixer Pre-Amp Dashboard . 2 Figure 3, Firmware Update Page . 5 Figure 4, Network Settings. 6 Figure 5, Appliance Configuration Settings. 9 Figure 6, Logs . 11 Figure 7, DSP Page with Channel Drop-Down Menu . 13 Figure 8, Compressor Settings. 17 Figure 9, Graphic EQ Settings . 18 Figure 10, High/Low Pass Parameters . 20 Figure 11, Limiter Settings . 23 Figure 12, Noise Gate Settings . 24 Figure 13, Parametric Equalizer Settings . 25 Figure 14, Router . 27 Figure 15, Router for Single Channel Bridged Mode and 2 Mono Mode Channels . 28 Figure 16, Settings Parameters for 2 Channel Mono. 29 Figure 17, Settings Parameters for 2 Single Channel Bridged . 29 Figure 18, Signal Present Parameters . 31 Figure 19, Status for 2 Channel . 32 Figure 20, Status When Channels 1 and 2 Are Bridged. 32 v vi List of Tables Table 1, Appliance Dashboard Read-Only Fields . 3 Table 2, Appliance Dashboard Buttons . 3 Table 3, Network Settings . 7 Table 4, Configuration Settings . 9 Table 5, Device Stations Settings . 10 Table 6, Logs. 12 Table 7, DSP Page . 14 Table 8, Compressor Settings . 17 Table 9, High Pass/Low Pass Parameters. 21 Table 10, Limiter Settings . 23 Table 11, Noise Gate Settings . 25 Table 12, Signal Present Parameters. 31 Table 13, Status . 33 vii viii Configuring the Four-Channel Audio Power Amplifiers Bogen’s Nyquist-based networked four-channel audio power ampli- fiers (NQ-A4060, NQ-A4120, NQ-A4300) support small, medium, and large Nyquist intercom solutions in schools and in commercial paging and public address solutions. Available in 240, 480, and 1200-watt models, the audio power ampli- fiers provide flexibility and versatility without the need for add-on modules. Each model offers state-of-the-art, built in Digital Signal Processing (DSP) software that includes factory loudspeaker presets and that turns the amplifier into a complete audio solution. A short press of the appliance’s Reset button reboots the device. If you press the Reset button for 10 seconds, the appliance returns to the factory default configuration settings. Returning to the default configuration settings does not change the appliance’s firmware. The following sections describe the process for manual configuration. For information about using Nyquist’s automatic configuration pro- cess, refer to the Nyquist System Administrator Manual. Note: Do not use third-party Chrome browser extensions with the Nyquist user interface. To access the appliance’s UI: Step 1 Access the appliance’s web UI by doing one of the fol- lowing: a On your web browser, enter the IP address for the appliance as the URL. b From the Nyquist web UI navigation bar, select Sta- tions, select Stations Status, navigate to the device that you want to configure, and then select the Link icon. 1 Figure 1, Nyquist Appliance Login Step 2 At the Nyquist Appliance - Login page, enter username and password, and then select Login. The default username is admin; the default password is bogen. The dashboard for the selected appliance appears. Figure 2, Matrix Mixer Pre-Amp Dashboard 2 1 Using the Dashboard The dashboard displays the following read-only fields: Table 1, Appliance Dashboard Read-Only Fields Device Type Identifies the physical device used by the station. Serial Number Identifies the serial number for the device. MAC Address Specifies the Media Access Control (MAC) address, which is a unique identifier assigned to network interfaces for commu- nications on the physical network segment. Firmware Version Provides the firmware version installed on the station. The dashboard also contains the following buttons: Table 2, Appliance Dashboard Buttons Dashboard Refreshes the dashboard. Configuration Set- Accesses the Configuration Settings page tings where you can either manually set various options, such as the SIP Username, or select to receive configuration settings from the server. Network Settings Accesses the Network Settings page where you can view and set network settings, such as the static IP address. Firmware Update Accesses the Firmware Update page where you can view the current Nyquist version, check for updates, restore factory settings, and reboot the appliance. Logs Accesses log files, which record either events or messages that occur when soft- ware runs and are used when trouble- shooting the appliance. DSP Accesses the DSP page where you can view and set parameters for Digital Signal Pro- cessing (DSP). 3 Table 2, Appliance Dashboard Buttons Help Accesses the appliance’s online help. Manual Displays the appliance’s configuration manual. Logout Logs out of the appliance’s dashboard. 2Updating Firmware When you select Firmware Update from the appliance’s web UI, the Firmware Update page appears. From this page you can determine which Nyquist version the appliance is using and if an update is required. You can also use this page to restore factory settings and to reboot the appliance. Note: A Nyquist appliance connected to the Nyquist network receives a configuration file from the Nyquist server that includes the latest firmware available from the server. If the firmware is later than the one installed on the appliance, an automatic firmware update occurs unless the Firmware parameter for the station is left blank. Refer to the Nyquist System Administrator Manual for more information. 4 Figure 3, Firmware Update Page To use the Firmware Update page: Step 1 On the appliance web UI’s main page, select Firmware Update to ensure you have the latest firmware version. Step 2 Select Upload Firmware to upload firmware from the server to the appliance. If you select this option, a popup screen appears that allows you to select the file that you want to upload. You can navigate to the file’s location. After you select the file, select Upload. If Nyquist discovers a new firm- ware version, the Firmware Update page displays an Update Firmware button. Select this button if you want to update the appliance’s firmware to the new version. Step 3 If you want to return your appliance to its original state (undoing firmware updates), select Restore Factory Settings. Step 4 Select Reboot Appliance to restart your appliance. 5 3 Setting Network Tab Parameters Network settings can be configured dynamically by the Nyquist server or manually by using the appliance’s web UI. To manually configure network settings: Step 1 On the appliance web UI’s main page, select Network Settings. Step 2 Select your desired network settings. Step 3 Select Save. Figure 4, Network Settings 6 Network settings are described in the following table: Table 3, Network Settings Static IP Identifies the fixed IP address assigned to the appliance by a system administra- tor. Netmask Identifies the subnetwork subdivision of an IP network. Gateway Identifies the address, or route, for the default gateway. VLAN ID Identifies the Virtual Local Area Network (VLAN) for this appliance. Values range from 0 to 4094. VLAN Priority Identifies the priority of the network traf- fic on the VLAN. Priority can range from 0 through 7. NTP Server Identifies the IP address or the domain name of the Network Time Protocol (NTP) Server. This field is read only. TFTP Server Identifies the IP address of the Trivial File Transfer Protocol (TFTP) server. TFTP is used by Nyquist VoIP phone and appli- ance provisioning. A TFTP server runs