Test & Measurement

Total Page:16

File Type:pdf, Size:1020Kb

Test & Measurement TEST & MEASUREMENT 2018 UNIVERSAL TEST & MEASUREMENT Testers ___________________________________________________________ 24 Voltage detectors ___________________________________________________ 28 Multimeters _______________________________________________________ 31 Digital ammeters ____________________________________________________ 40 Digital clamps ______________________________________________________ 42 ELECTRICAL SAFETY Installation testers ___________________________________________________ 62 Multimeter clamps for leakage current ____________________________________ 66 Insulation testers ____________________________________________________ 77 Earth and resistivity testers ____________________________________________ 79 Electrical equipment testers ___________________________________________ 87 Other testers _______________________________________________________ 91 Data processing software _____________________________________________ 100 ENERGY QUALITY & INSTALLATION MONITORING Power and harmonics clamps __________________________________________ 118 Power and energy quality analysers _____________________________________ 122 Solar power analysers _______________________________________________ 126 Recorders ________________________________________________________ 139 Data processing software _____________________________________________ 142 PHYSICAL & ENVIRONMENTAL MEASUREMENTS Calibrators _______________________________________________________ 154 Thermal cameras ___________________________________________________ 157 Thermometers _____________________________________________________ 164 Other physical and environmental measuring equipment ______________________ 172 RADIOFREQUENCY & MICROWAVE MEASUREMENTS LAN tester ________________________________________________________ 199 Field meters ______________________________________________________ 200 Directional wattmeters ______________________________________________ 202 LABORATORY & EDUCATIONAL EQUIPMENT Training benches ___________________________________________________ 207 Training cases _____________________________________________________ 210 Other instruments __________________________________________________ 213 CURRENT MEASUREMENT Current clamps ____________________________________________________ 221 Flexible sensors and probes ___________________________________________ 224 ACCESSORIES Protection, storage and transport _______________________________________ 232 Connection technology ______________________________________________ 238 Adapters and probes _________________________________________________ 242 Fuses ___________________________________________________________ 243 THE CHAUVIN ARNOUX GROUP ABOUT THE CHAUVIN ARNOUX GROUP YEARS OF 125 DEVELOPMENT Every story starts somewhere. The story of the Chauvin Arnoux company as an inventor and manufacturer of measurement instruments since 1893 is rich in developments and innovations. Today, its products bear witness to and reflect the sociological and technological changes and the industrial innovations which marked the previous century. A fascinating story that explains why and how Chauvin Arnoux’s image and personality evolved... in two colours. Logo on the company’s former main gate t is often said that at the root of knowledge is language, measurement instruments. Beige was also introduced or that the origin of an innovation was an idea,… yet it with the use of varnished wood in the casings, while is the individual, the person, who is really the source black was reserved for the instruments’ dials. Right from Iof knowledge and discoveries. This also applies to the start in 1893, the contrast between black and the electricity, which was not invented in the 19th century, but yellow of varnished wood soon became the norm for the discovered in the 6th century BCE by a Greek philosopher measurement instruments produced by Chauvin Arnoux. and scientist named Thales, the first person to note the electrostatic properties of amber. In a relatively short time, between 1900 and 1936, with the development of new technologies and new techniques From the beginning of the 19th century, there was the for working materials, yellow brass began to be used yellow of amber. Then manufactured goods began to with black Bakelite, eventually spreading to nearly all include the yellow of brass and copper, materials used our instruments. in measurement instruments, either for the casings Already known for its sense of designg and the of galvanometers or for the connections of electrical combination of its originall cocolourslours yyeyellowllloww bbrassrasss aandnd This calibration potentiometer dating from 1900 waswa 1895 reflection used with a standard battery and a galvanometer like galvanometer the one shown above. Its price was 195 francs! The Monoc L CdA 600 Polyclamp (1982) 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 4 ABOUT THE CHAUVIN ARNOUX GROUP black, in its measurement instruments, Chauvin Arnoux The MAN’X 500 series launched by Chauvin Arnoux, the reproduced these colours in its first corporate logo in very first multimeters made of a flexible material, further 1927. strengthened the company’s visual identity. In the 1940s, many measurement instruments only used At about the same time, Metrix launched several black or black and the silver-grey of ferrous metals, products with yellow casings and black platens, including sometimes painted. Chauvin Arnoux adapted its original the instruments in its MX 44 series (1988) followed by visual identity to suit the fashions of the time, which also the MX 51 series. corresponded to technical criteria for safety, life-span Over the years, Chauvin Arnoux has developed its visual extension or weight considerations linked to the metal identity across all its product ranges: its multimeters, and the manufacturing process used. wattmeters, megohmmeters and installation testers all bear the company’s colours The 1950s saw the arrival of rubber-like materials, used for the bases of portable instruments, and subsequently One last remark about colours: while yellow is always for the shockproof sheaths made of black neoprene, first seen as the colour of the sun and of certain kings or designed and patented by Metrix® and Chauvin Arnoux emperors in Asia, it is not so widely known that in in 1958. These shockproof sheaths later became widely physics, black is the symbol of a “black body”, meaning used on the handheld instrument market. a system which absorbs all the light it receives. Black and yellow? A historic tandem for Chauvin Arnoux which With the 1970s came plastics technology. This was was the first company to use this pairing for its corporate when Chauvin Arnoux launched worldwide its first visual identity in the early 20th century when it first innovative products made of black and yellow plastic: designed its logo in 1927. the CdA 8 tester in 1979, the CdA 600 multimeter clamp in 1982, followed by the whole range. Some Axel Arnoux earth testers, such as the Terca in 1985 and the Prowatt wattmeters in 1989, also had a yellow casing. The combination of yellow and black for on-site equipment began to spread with its use for safety signage and for identifying hazardous areas on site… This encouraged Chauvin Arnoux to launch the well- known IMEG 500 or ISOL1000 series in Europe and then in the United States with the company’s two colours. On both the FrenchFrenchh MICAMICA mulmultimetertimimeter inin 1985198985 andandtd thethhe ANAANAGRAFGRAF American version availableavailabable theth sasameme yeayear,r, the yelloyellow of Chauvin Arnoux is clearly in evideevidence. MX 51 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 5 THE CHAUVIN ARNOUX GROUP MEASUREMENT EXPERTS Founded in 1893 by Raphaël Chauvin and René Arnoux, CHAUVIN ARNOUX is an expert in the measurement of electrical and physical quantities in the industrial and tertiary sectors. Total control of product design and manufacturing in-house enables the Group to innovate constantly and to propose a very broad product and service offering meeting all its customers’ needs. The Group’s quality policy enables it to deliver products which comply with the specifications, as well as the international and national standards, in the metrological, environmental and user-safety sectors. 6 R&D departments 125 years worldwide Metering, and still measurement & thriving! &11% of revenues energy performance invested in R&D Portable test & measurement instrumentation Chauvin Arnoux®, Metrology Metrix®, Multimetrix® & regulatory expert measurement brands testing 5companies 7 production sites 3 in Normandy 1 in Lyon 1 in Milan (Italy) 1 in Dover (USA) 10 subsidiaries 1 in Shanghai Allemagne (China) Autriche Chine Espagne Etats-Unis Italie Liban Royaume-Uni Temperatures Design of optical sensors Suède in industrial for quality control Suisse processes in laboratories & in-line processes. A FEW FIGURES • 100 million euros • 1,000 employees • 7 production sites of sales revenues • 6 R&D departments • 11% of revenues • 10 subsidiaries across the world worldwide invested in R&D 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 6 THE CHAUVIN ARNOUX GROUP CHAUVIN ARNOUX TEST & MEASUREMENT CHAUVIN ARNOUX, the French international Group specialized in electrical measurement, relies on its Chauvin Arnoux® brand to propose a wide range of portable measuring instruments. Its offering covers: • electrical measurement (testers, multimeters and current clamps) • electrical safety testing (insulation testers, ohmmeters, earth/ground
Recommended publications
  • Equivalent Resistance
    Equivalent Resistance Consider a circuit connected to a current source and a voltmeter as shown in Figure 1. The input to this circuit is the current of the current source and the output is the voltage measured by the voltmeter. Figure 1 Measuring the equivalent resistance of Circuit R. When “Circuit R” consists entirely of resistors, the output of this circuit is proportional to the input. Let’s denote the constant of proportionality as Req. Then VRIoeq= i (1) This is the same equation that we would get by applying Ohm’s law in Figure 2. Figure 2 Interpreting the equivalent circuit. Apparently Circuit R in Figure 1 acts like the single resistor Req in Figure 2. (This observation explains our choice of Req as the name of the constant of proportionality in Equation 1.) The constant Req is called “the equivalent resistance of circuit R as seen looking into the terminals a- b”. This is frequently shortened to “the equivalent resistance of Circuit R” or “the resistance seen looking into a-b”. In some contexts, Req is called the input resistance, the output resistance or the Thevenin resistance (more on this later). Figure 3a illustrates a notation that is sometimes used to indicate Req. This notion indicates that Circuit R is equivalent to a single resistor as shown in Figure 3b. Figure 3 (a) A notion indicating the equivalent resistance and (b) the interpretation of that notation. Figure 1 shows how to calculate or measure the equivalent resistance. We apply a current input, Ii, measure the resulting voltage Vo, and calculate Vo Req = (1) Ii The equivalent resistance can also be measured using and ohmmeter as shown in Figure 4.
    [Show full text]
  • Part 2 - Condenser Testers and Testing Correctly Part1 Condenser Testers and Testing Correctly.Doc Rev
    Part 2 - Condenser Testers and Testing Correctly Part1_Condenser_Testers_And_Testing_Correctly.doc Rev. 2.0 W. Mohat 16/04/2020 By: Bill Mohat / AOMCI Western Reserve Chapter If you have read Part 1 of this Technical Series on Condensers, you will know that the overwhelming majority of your condenser failures are due to breakdown of the insulating plastic film insulating layers inside the condenser. This allows the high voltages created by the “arcing” across your breaker points to jump through holes in the insulating film, causing your ignition system to short out. These failures, unfortunately, only happen at high voltages (often 200 to 500Volts AC)….which means that the majority of “capacitor testers" and "capacitor test techniques" will NOT find this failure mode, which is the MAJORITY of the condenser failure you are likely to encounter. Bottom line is, to test a condenser COMPLETELY, you must test it in three stages: 1) Check with a ohmmeter, or a capacitance meter, to see if the condenser is shorted or not. 2) Assuming your condenser is not shorted, use a capacitance meter to make sure it has the expected VALUE of capacitance that your motor needs. 3) Assuming you pass these first two step2, you then need to test your condenser on piece of test equipment that SPECIFICALLY tests for insulation breakdown under high voltages. (As mentioned earlier, you ohmmeter and capacitance meter only put about one volt across a capacitor when testing it. You need to put perhaps 300 or 400 times that amount of voltage across the condenser, to see if it’s insulation has failed, allowing electricity to “arc across" between the metal plates when under high voltage stress.
    [Show full text]
  • (Ohmmeter). Aims: • Calibrating of a Sensitive Galvanometer for Measuring a Resistance
    Exp ( ) Calibrating of a sensitive galvanometer for measuring a resistance (Ohmmeter). Aims: • Calibrating of a sensitive galvanometer for measuring a resistance. The theory When a galvanometer is used as an ohmmeter for measuring an ohmic resistance R, the deviation angle θ of the galvanometer’s coil is directly proportional to the flowing current through the coil and inversely proportional to the value of the resistance. The deviation will reach to the maximum end when the resistance equals to zero or the current has the maximum value. For this reason, the scale will be divide by inversely way in comparison with the ammeter and the voltmeter. The original circuit as shown in Fig(1) consists of a dry cell(E) , rheostat and ammeter (A) are connected in series with small resistor s has the range of 1 omega. The two terminals of “s” are connected in parallel to another combination includes a sensitive galvanometer “G” which has internal resistance “r” and a resistors box “R”, this combination is called the measuring circuit. When the value of R equals zero, and by moving the rheostat in the original circuit, it is possible to set the flowing electric current in measuring the circuit as a maximum value od deviation in the galvanometer. By assigning different values of R, the deviation θ is decreasing with increasing the value of R or by another meaning when the flowing current through the galvanometer decreases. Therefore, the current through the galvanometer is inversely proportional to the value of R according the following Figure 1: Ohmmeter Circuit diagram equation; V=I(R+r) R=V/I-r or R=V/θ-r 1 | P a g e This is a straight-line equation between R and (1/θ) as shown in Fig(2).
    [Show full text]
  • Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science
    Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science 6.002 - Circuits and Electronics Fall 2004 Lab Equipment Handout (Handout F04-009) Prepared by Iahn Cajigas González (EECS '02) Updated by Ben Walker (EECS ’03) in September, 2003 This handout is intended to provide a brief technical overview of the lab instruments which we will be using in 6.002: the oscilloscope, multimeter, function generator, and the protoboard. It incorporates much of the material found in the individual instrument manuals, while including some background information as to how each of the instruments work. The goal of this handout is to serve as a reference of common lab procedures and terminology, while trying to build technical intuition about each instrument's functionality and familiarizing students with their use. Students with previous lab experience might find it helpful to simply skim over the handout and focus only on unfamiliar sections and terminology. THE OSCILLOSCOPE The oscilloscope is an electronic instrument based on the cathode ray tube (CRT) – not unlike the picture tube of a television set – which is capable of generating a graph of an input signal versus a second variable. In most applications the vertical (Y) axis represents voltage and the horizontal (X) axis represents time (although other configurations are possible). Essentially, the oscilloscope consists of four main parts: an electron gun, a time-base generator (that serves as a clock), two sets of deflection plates used to steer the electron beam, and a phosphorescent screen which lights up when struck by electrons. The electron gun, deflection plates, and the phosphorescent screen are all enclosed by a glass envelope which has been sealed and evacuated.
    [Show full text]
  • Using Multimeters
    ORESU-G1-77-005 C. 3 Usingmultimeters lVlarine electrorocs boats gPIII I,,",.", I,'59< ~4'pg,g!gg By EdwardKolbe DC voltmeter CommercialFisheries Engineer, OSU Marine ScienceCenter, Newport Most multirnetersare designedfor measuringboth DC and AC voltages. AssistantProfessor of Agricultural Engineering This bulletin concentrates on how to Oregon State University measureDC voltages;procedures for making AC measurementsare similar. First, plug one of the leadsinto the Multimeters measure electrical voltage, negativeterminal, properly called a resistance,and current, For wiring and jack, marked ! or "COM" for troubleshootingon boats,they can be common! . Standard electrical practice extremelyuseful. Applications include: usesthe black wire for the ground, checkingthe continuity of wiring which is usuallythe negativeterminal. locating breaksin opencircuits; testing The other lead usually red, to signify fusesand diodes;measuring battery the "hot" sideof the circuit! goesinto voltageand voltagedrop over wires and the positivejack, marked + !. After eIectricalloads; identifying "hot" and selectingthe proper DC voltagerange groundedwires; locatingshort circuitsor with the selector switch, measure DC smallcurrent leaks;and checking voltageby touchingthe -! lead to the alternator and generator output, negativeterminal or wire and the + ! A multimeter, also called a volt-ohm- lead to the positiveterminaI or wire. milliammeter VOM!, is actually three Selectingthe proper voltagerange is toob in one.It is a voltmetercapable of important. It is achieved
    [Show full text]
  • TI S4 Audio Frequency Test Apparatus.Pdf
    TECHNICAL INSTRUCTION S.4 Audio-frequency Test Apparatus BRITISH BROADCASTING , CORPORATION ENGINEERING DlVlSlON - ', : . iv- TECHNICAL INSTRUCTION S.4 Third Issue 1966 instruction S.4 Page reissued May. 1966 CONTENTS Page Section I . Amplifier Detector AD14 . 1.1 Section 2 . Variable Attenuator AT119 . Section 3 . Wheatstone Bridge BG/I . Section 4 . Calibration IJnit CALI1 . Section 5. Harmonic Routine Tester FHP/3 . Section 6 . 0.B. Testing Unit 0BT/2 . Section . 7 . Fixed-frequency Oscillators OS/9. OS/ 10. OS/ IOA . Section 8 . Variable-frequency Oscillators TS/5 .. TS/7 . 1' . TS/8 . TS/9 . TS/ 10. TS/ 1OP . Section 9 . Portable Oscillators PTS/9 . PTS/IO . ... PTS/12 . PTS/13 . PTS/l5 .... PTS/l6 .... Appendix . The Zero Phase-shift Oscillator with Wien-bridge Control Section 10. Transmission Measuring Set TM/I . Section 1 I . Peak Programme Meter Amplifiers PPM/2 ..... PPM/6 . TPM/3 . Section 12 Valve Test Panels VT/4. VT/5 "d . Section 13. Microphone Cable Tester MCT/I . Section 14 . Aural Sensitivity Networks ASN/3. ASN/4 Section 15 . Portable Amplifier Detector PAD19 . Section 16. Portable Intermodulation Tester PIT11 Section 17. A.C. Test Meters ATM/I. ATM/IP . Section 18 . Routine Line Testers RLT/I. RLT/IP . Section 19. Standard Level Panel SLP/3 . Section 20 . A.C. Test Bay AC/55 . Section 21 . Fixed-frequency Oscillators: OS2 Series Standard Level Meter ME1611 . INSTRUCTION S.4 Page reissued May 1966 ... CIRCUIT DIAGRAMS AT END Fig. 1. Amplifier Detector AD14 Fig. 2. Wheatstone Bridge BG/1 Fig. 3. Harmonic Routine Tester FHP/3 Fig. 4. Oscillator OS/9 Fig.
    [Show full text]
  • A History of Impedance Measurements
    A History of Impedance Measurements by Henry P. Hall Preface 2 Scope 2 Acknowledgements 2 Part I. The Early Experimenters 1775-1915 3 1.1 Earliest Measurements, Dc Resistance 3 1.2 Dc to Ac, Capacitance and Inductance Measurements 6 1.3 An Abundance of Bridges 10 References, Part I 14 Part II. The First Commercial Instruments 1900-1945 16 2.1 Comment: Putting it All Together 16 2.2 Early Dc Bridges 16 2.3 Other Early Dc Instruments 20 2.4 Early Ac Bridges 21 2.5 Other Early Ac Instruments 25 References Part II 26 Part III. Electronics Comes of Age 1946-1965 28 3.1 Comment: The Post-War Boom 28 3.2 General Purpose, “RLC” or “Universal” Bridges 28 3.3 Dc Bridges 30 3.4 Precision Ac Bridges: The Transformer Ratio-Arm Bridge 32 3.5 RF Bridges 37 3.6 Special Purpose Bridges 38 3,7 Impedance Meters 39 3.8 Impedance Comparators 40 3.9 Electronics in Instruments 42 References Part III 44 Part IV. The Digital Era 1966-Present 47 4.1 Comment: Measurements in the Digital Age 47 4.2 Digital Dc Meters 47 4.3 Ac Digital Meters 48 4.4 Automatic Ac Bridges 50 4.5 Computer-Bridge Systems 52 4.6 Computers in Meters and Bridges 52 4.7 Computing Impedance Meters 53 4.8 Instruments in Use Today 55 4.9 A Long Way from Ohm 57 References Part IV 59 Appendices: A. A Transformer Equivalent Circuit 60 B. LRC or Universal Bridges 61 C. Microprocessor-Base Impedance Meters 62 A HISTORY OF IMPEDANCE MEASUREMENTS PART I.
    [Show full text]
  • Model 372 Series 3 Ohmmeter INSTRUCTION MANUAL
    Model 372 Series 3 Ohmmeter INSTRUCTION MANUAL About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument in compliance with its original advertised specifications. Notes and Safety Information This Operator’s Manual contains warning headings which alert the user to check for hazardous conditions. These appear throughout this manual where applicable and are defined below. To ensure the safety of operating performance of this instrument, these instructions must be adhered to. Warning, refer to accompanying documents. Caution, risk of electric shock. Technical Assistance SIMPSON ELECTRIC COMPANY offers assistance Monday through Friday, 8:00 am to 4:30 pm Central Time. Contact Technical Support or Customer Service at (715) 588-3311 or visit our website at http://www.simpsonelectric.com Warranty and Returns SIMPSON ELECTRIC COMPANY warrants each instrument and other articles manu- factured by it to be free from defects in material and workmanship under normal use and service, its obligation under this warranty being limited to making good at its factory or other article of equipment which shall within one (1) year after delivery of such instrument or other article of equipment to the original purchaser be returned intact to it, or to one of its authorized service centers, with transportation charges prepaid, and which its examination shall disclose to its satisfaction to have been thus defective; this warranty being expressly in lieu of all other warranties expressed or implied and of all other obligations or liabilities on its part, and SIMPSON ELECTRIC COMPANY neither assumes nor authorizes any other persons to assume for it any other liability in connection with the sales of its products.
    [Show full text]
  • The OHM Meter an Ohmmeter Is an Electrical Instrument That Measures
    The OHM meter An ohmmeter is an electrical instrument that measures electrical resistance, the opposition to an electric current. Micro-ohmmeters (microhmmeter or microohmmeter) make low resistance measurements. Megohmmeters (aka megaohmmeter or in the case of a trademarked device Megger) measure large values of resistance. The unit of measurement for resistance is ohms (). The original design of an ohmmeter provided a small battery to apply a voltage to a resistance. It uses a galvanometer to measure the electric current through the resistance. The scale of the galvanometer was marked in ohms, because the fixed voltage from the battery assured that as resistance is decreased, the current through the meter would increase. Ohmmeters form circuits by themselves, therefore they cannot be used within an assembled circuit. A more accurate type of ohmmeter has an electronic circuit that passes a constant current (I) through the resistance, and another circuit that measures the voltage (V) across the resistance. According to the following equation, derived from Ohm's Law, the value of the resistance (R) is given by: On the ohms ranges of a normal multimeter the unknown resistance is connected in series with a battery and the meter and the scale reads backwards. A variable resistor is included in the circuit so that the meter can be adjusted to read full scale with the test terminals shorted (Fig 1). In the shunt ohmmeter a battery and variable resistor are connected across a milli ammeter and the resistor is adjusted so that the meter reads full scale with the test terminals are unconnected (Fig.2).
    [Show full text]
  • Keithley Offers a Variety of Educational Lab Instruments Designed to Speed and Simplify This Lab Experience
    Overview The basic circuits and electronics devices lab is one of the first electrical engineering lab courses students will take. In this lab, students become familiar with making basic electrical measurements using laboratory instruments such as digital multimeters (DMMs), power supplies, function generators, and oscilloscopes. Once they’ve developed some competence in the use of these tools, students begin learning how basic components such as resistors, diodes, transistors, and operational amplifiers function. By the end of their lab coursework, students should be able to design, assemble, and use basic electronic circuits and have the skills necessary to measure and characterize their designs. Keithley offers a variety of educational lab instruments designed to speed and simplify this lab experience. As a leading manufacturer of electronics laboratory instrumentation, Keithley understands the importance of a solid understanding of measurement science, particularly for engineering students. To make the lab experience as instructive as possible, Keithley offers a variety of lab instruments, such as our Series 2000 DMMs and Series 2400 and 2600A SourceMeter® instruments, that are well suited for student use in circuits and basic electronics labs. Measurement Example Example 1: 2-wire resistance measurements vs. 4-wire resistance measurements using a DMM Ohms law relates voltage V across a circuit component to current I through a circuit component and resistance R of that component: R = V/I. Two-terminal DMMs source test current through the measuring test leads, terminating at the HI-LO inputs of the DMM. This two-wire ohms system works fine for most resistance measurements applications. However, the I-R drop in the test leads (RL) can cause inaccuracies that become apparent in lower resistance measurements.See the figure to the left.
    [Show full text]
  • Model 2450 Interactive Sourcemeter® Instrument User's Manual
    www.keithley.com Model 2450 Interactive SourceMeter Instrument User’s Manual 2450-900-01 Rev. D / May 2015 *P245090001D* 2450-900-01D A Greater Measure of Confidence Model 2450 Interactive SourceMeter® Instrument User's Manual © 2015, Keithley Instruments Cleveland, Ohio, U.S.A. All rights reserved. Any unauthorized reproduction, photocopy, or use of the information herein, in whole or in part, without the prior written approval of Keithley Instruments is strictly prohibited. ® ® ® TSP , TSP-Link , and TSP-Net are trademarks of Keithley Instruments. All Keithley Instruments product names are trademarks or registered trademarks of Keithley Instruments, Inc. Other brand names are trademarks or registered trademarks of their respective holders. Document number: 2450-900-01 Rev. D / May 2015 Safety precautions The following safety precautions should be observed before using this product and any associated instrumentation. Although some instruments and accessories would normally be used with nonhazardous voltages, there are situations where hazardous conditions may be present. This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and maintenance information carefully before using the product. Refer to the user documentation for complete product specifications. If the product is used in a manner not specified, the protection provided by the product warranty may be impaired. The types of product users are: Responsible body is the individual or group responsible for the use and maintenance of equipment, for ensuring that the equipment is operated within its specifications and operating limits, and for ensuring that operators are adequately trained.
    [Show full text]
  • Electrical Theory Lesson 2: Basic Instruments and Measurements Are Placed in the Hollow Core of a Solenoid. When the Current
    Electrical Theory Lesson 2: Basic Instruments and Measurements This document contains the transcript for the entire lesson. Page 1: Welcome to Lesson 2 of Electrical Theory. This lesson covers the following objectives: • Explain the correct procedure for using an ammeter, a voltmeter, and an ohmmeter. • Interpret a linear scale. • Compute shunt resistor values. • Compute multiplier resistor values. • Interpret a nonlinear scale. • Discuss the concept of meter sensitivity. • Understand basic electrical diagrams. • State and explain Ohm’s Law Page 2: Meters come in two formats; analog and digital. Analog meters use a continuous scale readout that must be interpreted by means of a needle, while the digital multimeter uses a liquid crystal display (LCD) readout that needs no interpretation. Page 3: A common type of meter movement is the D'Arsonval movement. The movement consists of a permanent‐type magnet and a rotating coil in the magnetic field. An indicating needle is attached to the rotating coil. When a current passes through the moving coil, a magnetic field is produced. The field reacts with the stationary field and causes rotation (deflection) of the needle. This deflection force is proportional to the strength of the current flowing through the coil. When the current ceases to flow, the moving coil is returned to its "at rest" position by hair springs. The coil that rotates in the magnetic field is mounted on precision‐type jewel bearings, much like a fine watch. The jewel‐type bearings and mount is known as a D'Arsonval movement. Page 4: When connecting a meter to an electrical circuit, proper polarity must be maintained.
    [Show full text]