The Business Benefits of the Qlogic 8400 Series 10Gbe CNA for the Software- Defined Data Center

Total Page:16

File Type:pdf, Size:1020Kb

The Business Benefits of the Qlogic 8400 Series 10Gbe CNA for the Software- Defined Data Center Solution Sheet The Business Benefits of the QLogic 8400 Series 10GbE CNA for the Software- Defined Data Center KEY BENEFITS • High-Performance Network Overlays: VXLAN & NVGRE Tunneling Offloads • Simplified Migration to 10GbE: Switch Independent NIC Partitioning (NPAR) • Next Gen I/O Virtualization: Single Root I/O Virtualization (SR-IOV) • Single Pane of Glass Multi-Adapter Management (ACS) • More VMs per Server: Full FCoE and iSCSI Offloads OVERVIEW PERFORMANCE WITHOUT CPU BURDEN The QLogic 8400 Series Adapter combines a broad set of 10Gb In today’s Information Age, faster data means faster business. QLogic Ethernet features optimized for a virtualized Software-Defined Data leads the industry in providing high-performance hardware based true Center (SDDC) driven by Software Defined Networks (SDN). In Converged Network Adapters for all manner of data communication from addition, it features industry-leading performance by delivering “bare metal OS” 10GbE connectivity to virtualized SDN optimization and hardware-based true Converged Network Adapter (CNA) that fully the industry’s highest performing FCoE and iSCSI 10GbE Converged offloads FCoE and iSCSI storage networking traffic. Networking technology. INDUSTRY CHALLENGE Acceleration for Software Defined Networking—VXLAN/ Do more with less. NVGRE SUPPORT Networking, server, and storage virtualization technologies provide Software Defined Networking (SDN) was created in part to solve problems more flexibility and better Total Cost of Ownership of the IT systems associated with multi-tenant environments. A data center that hosts that run businesses today. A crucial decision confronts business hundreds of thousands of customers across many physical locations leaders building up or building out their IT infrastructure: What is the with virtualized customer workloads will need many VLANs and the best way to connect these highly virtualized resources within the data ability to share resources on different networks. To enable this wide center and out to customers? resource sharing, Microsoft created Network Virtualization Generic Routing Encapsulation (NVGRE) for Hyper-V and VMware created Virtual Extensible Not all networking adapters have the same capabilities. LAN (VXLAN) “tunneling protocols.” To optimize networking traffic, Some Ethernet adapters may be described as having “converged network adapters must be compatible with these tunneling protocols. networking” features to connect Fibre Channel or iSCSI storage to their servers but such claims can often by misleading. A QLogic The QLogic 8400 CNAs support tunneling offload within the adapter 8400 hardware based true Converged Network Adapter will provide hardware, which offers stateless offload support of tunneled network all the performance and virtualization capabilities expected in a traffic. In addition to fully supporting Windows Hyper-V NVGRE 10Gb Ethernet adapter and provide hardware based storage protocol and VMware vSphere VXLAN, the QLE8400 provides many other offloads that make it a clear leader in Performance, Reliability, virtualization features. and Control. The QLogic 8400 Series adapter delivers everything imaginable for today’s needs and tomorrow’s possibilities. SN0530904-00 Rev. A 10/14 1 The Business Benefits of the QLogic 8400 Series Solution Sheet Feature QLogic 8400 QLogic 8300 QLogic 8200 Intel X710 Intel X540 Line Rate Performance Switch Independent NIC Partitioning VXLAN / NVGRE Offloads SR-IOV Remote Adapter Management Multi-Protocol SAN Boot Support Full iSCSI Offload in the Adapter Full FCoE Offload in the Adapter Industry Leading Hardware based Full Offload of iSCSI & FCoE RELIABILITY Demartek compared the QLogic hardware based true Converged Network QLogic has over 20 years of experience building bullet-proof state-of-the- Adapters to our competitors in their report: art communications hardware. The QLE8400 has grown from 13 previous Demartek Evaluation of QLogic 57810S. product generations. This technology is fully adopted by every major tier-1 OEM. Passing rigorous OEM server certifications validates the 8400 Series The Demartek study includes data showing 100% higher IOPS for iSCSI adapter’s dependable functionality. and FCOE storage traffic as compared to Intel when “no offload” is used on either the Intel or the QLogic 10GbE adapter. Further, when the hardware CONTROL offloads are being utilized on the QLE8400 the performance jumps to The 8400 Series Adapter enables quick and easy multi-adapter over 384% higher IOPS per CPU for the QLE8400 as compared to the administration with full functionality. This lets SAN administrators discover, Intel adapter. configure, monitor, diagnose, provision, and control access across multiple physical servers, operating systems, and protocols. A 364% higher IOPS per CPU benchmark is more than a performance statistic—extremely improved CPU utilization yields a greater return on CONCLUSION investment. The QLE8400 frees up server CPU cycles, which makes more QLogic 8400 Series Adapter hardware effectively matches today’s ever- computing power available for running more customer VMs on the same evolving data center. Whether the infrastructure is virtualized or not, virtualized server. includes 10GbE features or converged networking, the QLE8400 is the networking adapter to choose for Performance, Reliability, and Control. Follow us: Share: Corporate Headquarters QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 949-389-6000 International Offices UK | Ireland | Germany | France | India | Japan | China | Hong Kong | Singapore | Taiwan | Israel www.qlogic.com © 2014 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic and the QLogic logo re registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners. Information supplied by QLogic Corporation is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this brochure. QLogic Corporation reserves the right, without notice, to make changes in product design or specifications. SN0530904-00 Rev. A 10/14 2 .
Recommended publications
  • Storage Area Networks Windows 2000 and Windows Server 2003
    Server Clusters : Storage Area Networks Windows 2000 and Windows Server 2003 Microsoft Corporation Published: March 2003 Abstract This document describes what storage area networks (SAN) are, how server clusters can be deployed in a SAN, and how the Microsoft® Windows® platform, and Windows clustering in particular, take advantage of storage area network technology. Microsoft® Windows® Server 2003 Technical Article The information contained in this document represents the current view of Microsoft Corporation on the issues discussed as of the date of publication. Because Microsoft must respond to changing market conditions, it should not be interpreted to be a commitment on the part of Microsoft, and Microsoft cannot guarantee the accuracy of any information presented after the date of publication. This document is for informational purposes only. MICROSOFT MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AS TO THE INFORMATION IN THIS DOCUMENT. Complying with all applicable copyright laws is the responsibility of the user. Without limiting the rights under copyright, no part of this document may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), or for any purpose, without the express written permission of Microsoft Corporation. Microsoft may have patents, patent applications, trademarks, copyrights, or other intellectual property rights covering subject matter in this document. Except as expressly provided in any written license agreement from Microsoft, the furnishing of this document does not give you any license to these patents, trademarks, copyrights, or other intellectual property. © 2003. Microsoft Corporation. All rights reserved. Microsoft, Windows, Windows NT, SQL Server, and the Windows logo are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
    [Show full text]
  • Data Sheet QLE8152 Dual Port 10Gbps Enhanced Ethernet to Pcie Converged Network Adapter
    D ATA S H E E T Third party information brought to you courtesy of Dell. QLE8152 Dual Port 10Gbps Enhanced Ethernet to PCIe Converged Network Adapter Fibre Channel over Ethernet (FCoE) Technology. FCoE provides an opportunity to reduce data center costs by converging data and storage networking. Standard TCP/IP and Fibre Channel traffic can both run on the same high speed 10Gbps Ethernet wire, resulting in cost savings High Performance through reduced adapter, switch, cabling, power, cooling, and management requirements. FCoE has gained rapid market traction because it delivers • 10Gbps per port maximum throughput for high excellent performance, reduces data center TCO, and protects current data bandwidth storage (SAN) and networking (LAN) center investment. traffic • Full hardware offload for FCoE protocol processing iSCSI. The QLE8152 even supports iSCSI storage protocol using iSCSI • 250,000 IOPS per port deliver high I/O transfer software initiators, which are available with all major operating systems. rates for storage applications • Full support for TCP/IP and Ethernet performance High Performance. The QLE8152 boosts system performance with 10Gbps enhancements such as priority-based flow control speed and full hardware offload for FCoE protocol processing. Cutting edge (802.1Qbb), jumbo frames, checksum offloads, and 10Gbps bandwidth eliminates performance bottlenecks in the I/O path with segmentation offloads a 10X data rate improvement versus existing 1Gbps Ethernet solutions. Additionally, full hardware offload for FCoE protocol processing reduces Lower Total Cost of Ownership (TCO) system CPU utilization for I/O operations, which leads to faster application performance and higher levels of consolidation in virtualized systems. • Reduced hardware, cabling, power, cooling, and management costs through convergence of data Lower TCO.
    [Show full text]
  • System Design for Telecommunication Gateways
    P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come SYSTEM DESIGN FOR TELECOMMUNICATION GATEWAYS Alexander Bachmutsky Nokia Siemens Networks, USA A John Wiley and Sons, Ltd., Publication P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come SYSTEM DESIGN FOR TELECOMMUNICATION GATEWAYS P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come SYSTEM DESIGN FOR TELECOMMUNICATION GATEWAYS Alexander Bachmutsky Nokia Siemens Networks, USA A John Wiley and Sons, Ltd., Publication P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come This edition first published 2011 C 2011 John Wiley & Sons, Ltd Registered office John Wiley & Sons Ltd, The Atrium, Southern Gate, Chichester, West Sussex, PO19 8SQ, United Kingdom For details of our global editorial offices, for customer services and for information about how to apply for permission to reuse the copyright material in this book please see our website at www.wiley.com. The right of the author to be identified as the author of this work has been asserted in accordance with the Copyright, Designs and Patents Act 1988. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, except as permitted by the UK Copyright, Designs and Patents Act 1988, without the prior permission of the publisher.
    [Show full text]
  • End-To-End SAN Infrastructure
    Brochure QLogic. End-to-End SAN Infrastructure. HBAs Switches End-to-End SAN Infrastructure Routers Storage Virtualization Corporate Headquarters QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 949.389.6000 Europe Headquarters QLogic (UK) LTD. Surrey Technology Centre 40 Occam Road Guildford Surrey GU2 7YG UK +44 (0)1483 295825 © 2006 QLogic Corporation. All rights reserved. QLogic, the QLogic Logo, the Powered by QLogic Logo, SANbox, SANsurfer, SAN Express, SANmark, SANtrack, Designed to the Core, HyperStack, ReadyPath, and SmartWrite are registered trademarks or trademarks of QLogic Corporation. SANblade is a registered trademark of QLogic in the United States. All other brands and product names are trademarks or registered trademarks of their respective owners. Information supplied by QLogic is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this brochure. QLogic Corporation reserves the right, without notice, to makes changes in product design or specifications. SN0030522-00 Rev A 9/06 3 End-to-End End-to-end SAN infrastructure from QLogic. SANblade® Host Bus Adapters (HBAs) provide server connectivity throughout the SAN. SANbox® switches provide the switched fabric that connects servers to storage. SANbox Intelligent Storage Routers connect low-cost servers to SAN storage and allow you to replicate data across a WAN. The SANbox® Storage Services Platform provides network-based storage virtualization to form a pool of easy-to-manage storage. And QLogic network
    [Show full text]
  • Qlogic 4Gb Fibre Channel Expansion Card for IBM <Phsave;201;211>
    QLogic 4Gb Fibre Channel Expansion Card for Eserver IBM BladeCenter Installation Guide QLogic 4Gb Fibre Channel Expansion Card for Eserver IBM BladeCenter Installation Guide Note: Before using this information and the product it supports, read the general information in Appendix B, “IBM Statement of Limited Warranty Z125-4753-08 04/2004,” on page 29 and Appendix C, “Notices,” on page 53. First Edition (September 2005) © Copyright International Business Machines Corporation 2005. All rights reserved. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Safety . .v Chapter 1. Introduction . .1 Fibre Channel overview . .2 Related documentation . .2 Features and specifications . .4 Inventory checklist . .6 Notices and statements used in this book . .6 Major components of the Fibre Channel expansion card . .6 Chapter 2. Installing a Fibre Channel expansion card . .7 Handling static-sensitive devices . .7 Installation guidelines . .7 Installing the Fibre Channel expansion card on a blade server . .9 Configuring a command session . .9 Chapter 3. Updating the boot code and firmware and installing device drivers . .11 Installing the device drivers . .11 Chapter 4. Using Fast!UTIL . .13 Starting Fast!UTIL . .13 Using the configuration settings menu . .13 Selecting the host adapter . .13 Configuring the host adapter . .13 Configuring the selectable boot settings . .16 Restoring default settings . .16 Accessing Raw NOVRAM data . .16 Accessing advanced adapter settings . .16 Scanning for Fibre Channel devices . .18 Using the Fibre Channel disk utility . .18 Performing a loopback data test . .18 Using ExitFast!UTIL . .18 Chapter 5. Using the SANsurfer application . .19 Overview of the QLogic SANsurfer application .
    [Show full text]
  • Qlogic Fibre Channel Stack
    Technology Brief QLogic® Fibre Channel Driver Stack Field-Proven as the Most Diverse, Stable, and Reliable Driver Architecture QLogic® adapters from Marvell® are the world’s largest installed base of Fibre Channel Adapters with more than 20 million ports shipped. QLogic Fibre Channel Stack QLogic adapters from Marvell are the most established, proven Fibre Channel stack in the industry and has held over ten consecutive years of Fibre Channel market leadership. Executive Summary QLogic technology from Marvell is at the forefront of data and storage networking QLogic Fibre Channel Stack innovation with a multi-faceted product portfolio of Fibre Channel, Fibre Channel with server-based caching, Ethernet, Fibre Channel over Ethernet (FCoE), and iSCSI network- Key Benefits ing solutions. When it comes to best-in-class interoperability, performance, power optimization, reliability, and ease of use, the top storage area networking companies in the world rely on QLogic adapters from Marvell. With more than 20 years of consistent • Field-Proven storage networking expertise, QLogic technology offers market-leading Fibre Channel • Higher Uptime Adapters that leverage the QLogic Fibre Channel stack with unsurpassed reliability and a diverse offering of products to fit virtually every SAN deployment. • Superior Performance For Enterprise Applications The QLogic Fibre Channel stack from Marvell has been field-proven over years of extensive internal testing, stringent OEM qualifications, and world-class engineering • Unmatched Scalability For Virtualized Environments development expertise. QLogic adapters from Marvell offer the most established and proven Fibre Channel stack in the industry and has over ten consecutive years of Fibre Investment Protection • Channel market leadership. QLogic adapters from Marvell are the world’s largest • Lower Cost Of Ownership installed base of Fibre Channel Adapters with more than 20 million ports shipped.
    [Show full text]
  • Introduction to Storage Area Networks
    SG24-5470- Introduction to Storage Area Networks Jon Tate Pall Beck Hector Hugo Ibarra Shanmuganathan Kumaravel Libor Miklas Redbooks International Technical Support Organization Introduction to Storage Area Networks December 2017 SG24-5470-08 Note: Before using this information and the product it supports, read the information in “Notices” on page ix. Ninth Edition (December 2017) This edition applies to the products in the IBM Storage Area Networks (SAN) portfolio. © Copyright International Business Machines Corporation 2017. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . ix Trademarks . .x Preface . xi Authors. xii Now you can become a published author, too! . xiv Comments welcome. xiv Stay connected to IBM Redbooks . xiv Summary of changes. .xv December 2017, Ninth Edition . .xv Chapter 1. Introduction. 1 1.1 Networks . 2 1.1.1 The importance of communication . 2 1.2 Interconnection models . 2 1.2.1 The open systems interconnection model. 2 1.2.2 Translating the OSI model to the physical world. 4 1.3 Storage . 5 1.3.1 Storing data. 5 1.3.2 Redundant Array of Independent Disks . 6 1.4 Storage area networks . 11 1.5 Storage area network components . 13 1.5.1 Storage area network connectivity . 14 1.5.2 Storage area network storage. 14 1.5.3 Storage area network servers. 14 1.6 The importance of standards or models . 14 Chapter 2. Storage area networks . 17 2.1 Storage area networks . 18 2.1.1 The problem . 18 2.1.2 Requirements .
    [Show full text]
  • Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance
    Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance August 2012 By Tom Hanvey; update by Peter Brouwer This paper describes how to implement a Fibre Channel (FC) SAN boot solution using Oracle's Sun ZFS Storage Appliance on a high-availability SAN. This solution has been validated with a variety of servers, operating systems, and hardware configurations. Introduction Overview Benefits of Booting from a SAN FC SAN Boot Configuration Requirements Configuring the Sun ZFS Storage Appliance for Fibre Channel Boot Configuring the Client Server for Fibre Channel SAN Boot Installing the Operating System on the Server FC SAN Boot Time Test Results Best Practices Conclusion Appendix: References Introduction Organizations are continually looking for ways to simplify their management infrastructure, enhance scalability, and reduce costs while increasing reliability and performance in their data center. Booting from a storage area network (SAN) offers many benefits, leading to cost savings as well as higher levels of protection, ease of management, increased flexibility, and reduced down time. Traditionally, operating systems have been installed on internal disks on individual servers or on direct attached storage (DAS). This approach presents a number of challenges to an IT organization. Dedicated internal boot devices cannot be shared with other servers, so are often underutilized. IT staff must perform management tasks on these systems locally rather than from a central management system, leading to increased administrative costs. For optimal redundancy and performance, additional RAID software or host bus adapters (HBAs) are required to manage these storage devices. Local disks on individual servers present particular challenges for multi-site administration and disaster recovery site maintenance.
    [Show full text]
  • EMC® Host Connectivity with Qlogic Fibre Channel and Iscsi Host Bus
    EMC® Host Connectivity with QLogic Fibre Channel and iSCSI Host Bus Adapters (HBAs) and Fibre Channel over Ethernet Converged Network Adapters (CNAs) for the Linux Environment P/N 300-002-803 REV A21 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.EMC.com Copyright © 2001–2012 EMC Corporation. All rights reserved. Published March, 2012 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS IS.” EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. For the most up-to-date regulatory document for your product line, go to the EMC Powerlink website. All other trademarks used herein are the property of their respective owners. 2 EMC Host Connectivity with QLogic FC and iSCSI HBAs and FCoE CNAs for the Linux Environment Contents Preface............................................................................................................................ 11 Chapter 1 Introduction Purpose of this document................................................................ 16 Host connectivity
    [Show full text]
  • IBM Bladecenter : Qlogic Virtual Fabric Extension Module
    IBM Europe, Middle East, and Africa Hardware Announcement ZG09-0804, dated December 15, 2009 IBM BladeCenter : QLogic Virtual Fabric Extension Module Table of contents 1 Overview 2 Product number 2 Key prerequisites 3 Technical information 2 Planned availability date 4 Terms and conditions 2 Description 5 Prices 2 Product positioning 6 Announcement countries At a glance The QLogic Virtual Fabric Extension Module is the latest Ethernet switching option for the IBM® BladeCenter®. This offering allows BladeCenter integration with virtually any open-standards-based local area network (LAN). Overview Blades have made inroads into enterprise data centers by delivering higher density with a lower footprint and reduced costs for power and cooling compared to traditional rack servers. Now with multicore environments, there is an increased need for faster I/O such as 10 Gb Ethernet. QLogic Virtual Fabric Extension Module for IBM BladeCenter IBM has been at the forefront of offering new technology to clients. The QLogic Virtual Fabric Extension Module is another example of IBM's innovation. IBM was among the first to deliver Fibre Channel over Ethernet (FCoE) across System x® and BladeCenter and this new module takes this a step further by offering clients IO convergence inside the chassis. Clients using the BNT 10 Gb switch (part number 46C7191) for their LAN traffic can now combine it with this module and the QLogic CNA (#42C1830) to converge their LAN and SAN on a single network. This not only offers a simplified fabric, but also offers significant savings over separate 10 Gb/8 Gb infrastructure. Other than the cost and management savings, this solution provides the flexibility to upgrade existing chassis to implement IO convergence without replacing existing 10 Gb switch.
    [Show full text]
  • Fibre Channel Adapters
    Marvell® QLogic® Fibre Channel Adapters QLE2660-DEL, QLE2662-DEL, QME2662-DEL, QLE2690-DEL, QLE2690L-DEL, QLE2692-DEL, QLE2692L-DEL, and QME2692-DEL User’s Guide Third party information brought to you courtesy of Dell. Doc. No. CU0354604-00 Rev. X January 21, 2021 Cover Marvell Fibre Channel Adapters User’s Guide THIS DOCUMENT AND THE INFORMATION FURNISHED IN THIS DOCUMENT ARE PROVIDED “AS IS” WITHOUT ANY WARRANTY. MARVELL AND ITS AFFILIATES EXPRESSLY DISCLAIM AND MAKE NO WARRANTIES OR GUARANTEES, WHETHER EXPRESS, ORAL, IMPLIED, STATUTORY, ARISING BY OPERATION OF LAW, OR AS A RESULT OF USAGE OF TRADE, COURSE OF DEALING, OR COURSE OF PERFORMANCE, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT. This document, including any software or firmware referenced in this document, is owned by Marvell or Marvell's licensors, and is protected by intellectual property laws. No license, express or implied, to any Marvell intellectual property rights is granted by this document. The information furnished in this document is provided for reference purposes only for use with Marvell products. It is the user's own responsibility to design or build products with this information. Marvell products are not authorized for use as critical components in medical devices, military systems, life or critical support devices, or related systems. Marvell is not liable, in whole or in part, and the user will indemnify and hold Marvell harmless for any claim, damage, or other liability related to any such use of Marvell products. Marvell assumes no responsibility for the consequences of use of such information or for any infringement of patents or other rights of third parties that may result from its use.
    [Show full text]
  • Qlogic Bcm57xx and Bcm57xxx
    User’s Guide Ethernet iSCSI Adapters and Ethernet FCoE Adapters QLogic BCM57xx and BCM57xxx Third party information brought to BC0054508-00 J you courtesy of Dell. User’s Guide—Ethernet iSCSI Adapters and Ethernet FCoE Adapters QLogic BCM57xx and BCM57xxx Document Revision History Revision A, February 18, 2015 Revision B, July 29, 2015 Revision C, March 24, 2016 Revision D, April 8, 2016 Revision E, February 2, 2017 Revision F, August 25, 2017 Revision G, December 19, 2017 Revision H, March 15, 2018 Revision J, April 13, 2018 Changes Sections Affected Changed Step 1. “Downloading Documents” on page xxiii Added support for NPIV (via Fibre Channel - Link “FCoE” on page 4 Services specification) on Linux and Windows. In the first paragraph, clarified the last sentence to “Configuring Teaming in Windows Server” on indicate that “Windows Server 2016 and later do page 7 not support QLogic’s QLASP teaming driver.” In the NOTE, clarified the last sentence to indicate “QLASP Overview” on page 7 that “Windows Server 2016 does not support QLogic’s QLASP teaming driver…” In the NOTE, clarified the first and second sen- “Link Aggregation (802.3ad)” on page 9 tences: “The static and dynamic Link Aggregation (switch dependent) team type is not supported on ports with NIC partitioning (NPAR) mode enabled or iSCSI-offload enabled. Some switches support FCoE-offload in dynamic LACP teaming mode.” Added RHEL 6.9, 7.4, 7.5, SLES12 SP3 to the list “Linux” on page 18 of supported OSs. Added ESXi 6.0 U3, ESXi 6.5 U1, ESXi 6.5 U2, “VMware ESXi” on page 19 ESXi 6.7 to the list of supported OSs.
    [Show full text]