SAS Storage Architecture

Total Page:16

File Type:pdf, Size:1020Kb

SAS Storage Architecture world-class technical training Are your company’s technical training needs being addressed in the most effective manner? MindShare has over 25 years experience in conducting technical training on cutting-edge technologies. We understand the challenges companies have when searching for quality, effective training which reduces the students’ time away from work and provides cost-effective alternatives. MindShare offers many fl exible solutions to meet those needs. Our courses are taught by highly-skilled, enthusiastic, knowledgeable and experienced instructors. We bring life to knowledge through a wide variety of learning methods and delivery options. training that fi ts your needs MindShare recognizes and addresses your company’s technical training issues with: • Scalable cost training • Customizable training options • Reducing time away from work • Just-in-time training • Overview and advanced topic courses • Training delivered effectively globally • Training in a classroom, at your cubicle or home offi ce • Concurrently delivered multiple-site training MindShare training courses expand your technical skillset 2 PCI Express 2.0 ® 2 Serial Attached SCSI (SAS) 2 Intel Core 2 Processor Architecture 2 DDR2/DDR3 DRAM Technology 2 AMD Opteron Processor Architecture 2 PC BIOS Firmware 2 Intel 64 and IA-32 Software Architecture 2 High-Speed Design 2 Intel PC and Chipset Architecture 2 Windows Internals and Drivers 2 PC Virtualization 2 Linux Fundamentals 2 USB 2.0 ... and many more. 2 Wireless USB All courses can be customized to meet your 2 Serial ATA (SATA) group’s needs. Detailed course outlines can be found at www.mindshare.com bringing life to knowledge. real-world tech training put into practice worldwide *PCI Express ® is a registered trademark of the PCISIG MindShare Learning Options MindShare MindShare MindShare MindShare Classroom Virtual Classroom eLearning Press Intro eLearning In-House Training Virtual In-House Training Books Modules Comprehensive Public Training Virtual Public Training eLearning Modules eBooks Classroom Training Virtual Classroom Training eLearning Module Training MindShare Press Invite MindShare to train The majority of our courses MindShare is also an eLearning Purchase our books and you in-house, or sign-up to live over the web in an inter- company. Our growing list of eBooks or publish your attend one of our many public active environment with WebEx interactive eLearning modules own content through us. classes held throughout the and a phone bridge. We deliver include: MindShare has authored year and around the world. training cost-effectively across • Intro to Virtualization over 25 books and the list No more boring classes, the multiple sites and time zones. Technology is growing. Let us help ‘MindShare Experience‘ is Imagine being trained in your • Intro to IO Virtualization make your book project sure to keep you engaged. cubicle or home offi ce and • Intro to PCI Express 2.0 a successful one. avoiding the hassle of travel. Updates Contact us to attend one of • PCI Express 2.0 our public virtual classes. • USB 2.0 • AMD Opteron Processor Architecture • Virtualization Technology ...and more Engage MindShare Have knowledge that you want to bring to life? MindShare will work with you to “Bring Your Knowledge to Life.” Engage us to transform your knowledge and design courses that can be delivered in classroom or virtual class- room settings, create online eLearning modules, or publish a book that you author. We are proud to be the preferred training provider at an extensive list of clients that include: ADAPTEC • AMD • AGILENT TECHNOLOGIES • APPLE • BROADCOM • CADENCE • CRAY • CISCO • DELL • FREESCALE GENERAL DYNAMICS • HP • IBM • KODAK • LSI LOGIC • MOTOROLA • MICROSOFT • NASA • NATIONAL SEMICONDUCTOR NETAPP • NOKIA • NVIDIA • PLX TECHNOLOGY • QLOGIC • SIEMENS • SUN MICROSYSTEMS SYNOPSYS • TI • UNISYS 4285 SLASH PINE DRIVE COLORADO SPRINGS, CO 80908 USA M 1.602.617.1123 O 1.800.633.1440 [email protected] www.mindshare.com SAS Storage Architecture (Revision 1.1) MINDSHARE, INC. Mike Jackson MINDSHARE PRESS The authors and publishers have taken care in preparation of this book, but make no expressed or implied warranty of any kind and assume no responsibility for errors or omissions. No liability is assumed for incidental or consequential damages in connec- tion with or arising out of the use of the information or programs contained herein. Visit MindShare, Inc. on the web: www.mindshare.com Library of Congress Control Number: 2005931901 Copyright ©2005 by MindShare, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopy- ing, recording, or otherwise, without the prior written permission of the publisher. Printed in the United States of America. For information on obtaining permission for use of material from this work, please sub- mit a written request to: MindShare Press Attn: Robin Winkles 4285 Slash Pine Dr. Colorado Springs, CO 80908 Fax: 719-487-1434 Set in 10-point Palatino by MindShare, Inc. ISBN 0977087808 First Printing September 2005 Revision History Date Revision Description - Fixed Table of Contents chapter numbers. - Page 104 – “SAS implements the SATA Tunneled Protocol…” - Page 141 – third line of first paragraph, SPC-3 was July 2007 1.1 changed to SBC-3 - Figure 16-8 – the transmitter buffer was removed from the drawing. This buffer is in the Physical Layer. - Table 19-1 – third entry was changed to “2 to (n-4)” - Corrected minor grammatical errors. September 2005 1.0 - Initial Release Contents About This Book Scope............................................................................................................................................. 1 The MindShare Architecture Series ....................................................................................... 1 Cautionary Note ......................................................................................................................... 2 The Standard Is the Final Word .............................................................................................. 3 Documentation Conventions................................................................................................... 3 Hexadecimal Notation ........................................................................................................ 3 Binary Notation.................................................................................................................... 3 Decimal Notation ................................................................................................................. 4 Bits Versus Bytes Notation ................................................................................................. 4 Bit Fields (Logical Groups of Bits or Signals) .................................................................. 4 Visit Our Web Site..................................................................................................................... 5 We Want Your Feedback...........................................................................................................5 Part 1: Introduction Chapter 1: The Motivation for SAS Introduction................................................................................................................................. 9 Serial SCSI................................................................................................................................. 10 General................................................................................................................................. 10 Earlier Serial Buses Supported SCSI ............................................................................... 11 SAS Design Goals.................................................................................................................... 13 The SAS Solution..................................................................................................................... 14 Bandwidth........................................................................................................................... 15 Advantages ......................................................................................................................... 15 Positioning SAS........................................................................................................................ 17 Disk Drive Comparison.......................................................................................................... 19 Interface Comparison .............................................................................................................. 21 Example Topology ................................................................................................................... 23 Usage Model Summary........................................................................................................... 25 Chapter 2: Origins of SAS and Background Background for Serial SCSI ................................................................................................... 27 SCSI Background ............................................................................................................... 28 SCSI Definitions ................................................................................................................. 31 Problems with Parallel SCSI............................................................................................
Recommended publications
  • Clustered Data ONTAP® 8.3 SAN Configuration Guide
    Updated for 8.3.1 Clustered Data ONTAP® 8.3 SAN Configuration Guide NetApp, Inc. Telephone: +1 (408) 822-6000 Part number: 215-10114_A0 495 East Java Drive Fax: +1 (408) 822-4501 June 2015 Sunnyvale, CA 94089 Support telephone: +1 (888) 463-8277 U.S. Web: www.netapp.com Feedback: [email protected] Table of Contents | 3 Contents Considerations for iSCSI configurations .................................................... 5 Ways to configure iSCSI SAN hosts with single nodes .............................................. 5 Ways to configure iSCSI SAN hosts with HA pairs ................................................... 7 Benefits of using VLANs in iSCSI configurations ..................................................... 8 Static VLANs .................................................................................................. 8 Dynamic VLANs ............................................................................................. 9 Considerations for FC configurations ...................................................... 10 Ways to configure FC SAN hosts with single nodes ................................................. 10 Ways to configure FC with HA pairs ........................................................................ 12 FC switch configuration best practices ..................................................................... 13 Supported number of FC hop counts ......................................................................... 13 Supported FC ports ...................................................................................................
    [Show full text]
  • SAS Storage Architecture: Serial Attached SCSI, 2005, Mike Jackson, 0977087808, 9780977087808, Mindshare Press, 2005
    SAS Storage Architecture: Serial Attached SCSI, 2005, Mike Jackson, 0977087808, 9780977087808, MindShare Press, 2005 DOWNLOAD http://bit.ly/1zNQCoA http://www.barnesandnoble.com/s/?store=book&keyword=SAS+Storage+Architecture%3A+Serial+Attached+SCSI SAS (Serial Attached SCSI) is the serial storage interface that has been designed to replace and upgrade SCSI, by far the most popular storage interface for high-performance systems for many years. Retaining backward compatibility with the millions of lines of code written to support SCSI devices, SAS incorporates recent advances in high-speed serial design to provide better performance, better reliability and enhanced capabilities, all at a lower cost. SAS will be a significant part of many future high-performance storage systems, and hardware designers, system validation engineers, device driver developers and others working in this area will need a working knowledge of it.SAS Storage Architecture provides a comprehensive guide to the SAS standard. The book contains descriptions and numerous examples of the concepts presented, using the same building block approach as other MindShare offerings. This book details important concepts relating to the design and implementation of storage networks.Specific topics of interest include:SATA Compatibility Expander devices Discovery Process Connection protocols Arbitration of competing connection requests Flow Control protocols ACK/NAK protocol Primitives ? construction and uses Frames ? format, definition, used of each field Error checking mechanisms
    [Show full text]
  • Fibre Channel Interface
    Fibre Channel Interface Fibre Channel Interface ©2006, Seagate Technology LLC All rights reserved Publication number: 100293070, Rev. A March 2006 Seagate and Seagate Technology are registered trademarks of Seagate Technology LLC. SeaTools, SeaFONE, SeaBOARD, SeaTDD, and the Wave logo are either registered trade- marks or trademarks of Seagate Technology LLC. Other product names are registered trade- marks or trademarks of their owners. Seagate reserves the right to change, without notice, product offerings or specifications. No part of this publication may be reproduced in any form without written permission of Seagate Technol- ogy LLC. Revision status summary sheet Revision Date Writer/Engineer Sheets Affected A 03/08/06 C. Chalupa/J. Coomes All iv Fibre Channel Interface Manual, Rev. A Contents 1.0 Contents . i 2.0 Publication overview . 1 2.1 Acknowledgements . 1 2.2 How to use this manual . 1 2.3 General interface description. 2 3.0 Introduction to Fibre Channel . 3 3.1 General information . 3 3.2 Channels vs. networks . 4 3.3 The advantages of Fibre Channel . 4 4.0 Fibre Channel standards . 5 4.1 General information . 6 4.1.1 Description of Fibre Channel levels . 6 4.1.1.1 FC-0 . .6 4.1.1.2 FC-1 . .6 4.1.1.3 FC-1.5 . .6 4.1.1.4 FC-2 . .6 4.1.1.5 FC-3 . .6 4.1.1.6 FC-4 . .7 4.1.2 Relationship between the levels. 7 4.1.3 Topology standards . 7 4.1.4 FC Implementation Guide (FC-IG) . 7 4.1.5 Applicable Documents .
    [Show full text]
  • Crack Iscsi Cake 197
    1 / 2 Crack Iscsi Cake 197 Open-E DSS V7 increases iSCSI target efficiency by supporting ... drive serial number and the drive serial number information from the robotic library), ... Open-E DSS V7 MANUAL www.open-e.com. 197 work in that User .... nuance pdf converter professional 8 crack keygen · avunu telugu movie english subtitles download torrent · Veerappan ... Crack Iscsi Cake 197.. Crack Iscsi Cake 1.97. Download. Crack Iscsi Cake 1.97. ISCSI...CAKE...1.8.0418...CRACK.. Merci..de..tlcharger..iSCSI.. Contribute to Niarfe/hack-recommender development by creating an account on GitHub. ... 197, ETAP. 198, EtQ. 199, Cincom Eloquence ... 1022, Adobe Target. 1023, Adobe ... 3485, Dell EqualLogic PS6500E iSCSI SAN Storage. 3486, Dell .... iscsi cake, iscsi cake crack, iscsi cake 1.8 crack full, iscsi cake 1.97 full, iscsi cake tutorial, iscsi cake 1.9 crack, iscsi cake 1.9 full, iscsi cake .... Crack Iscsi Cake 197 iscsi cake, iscsi cake 1.8 crack full, iscsi cake 1.9, iscsi cake full, iscsi cake 1.9 expired, iscsi cake crack, iscsi cake 1.9 full, .... Crack Iscsi Cake 197. June 16 2020 0. iscsi cake, iscsi cake 1.8 crack full, iscsi cake full, iscsi cake 1.8 serial number, iscsi cake 1.9, iscsi cake crack, iscsi cake ... Serial interface and protocol. Standard PC mice once used the RS-232C serial port via a D-subminiature connector, which provided power to run the mouse's .... Avira Phantom VPN Pro v3.7.1.26756 Final Crack (2018) .rar · fb limiter pro cracked full version ... Crack Iscsi Cake 197 · Hoshi Wo Katta Hi ...
    [Show full text]
  • SAS Enters the Mainstream Although Adoption of Serial Attached SCSI
    SAS enters the mainstream By the InfoStor staff http://www.infostor.com/articles/article_display.cfm?Section=ARTCL&C=Newst&ARTICLE_ID=295373&KEYWORDS=Adaptec&p=23 Although adoption of Serial Attached SCSI (SAS) is still in the infancy stages, the next 12 months bode well for proponents of the relatively new disk drive/array interface. For example, in a recent InfoStor QuickVote reader poll, 27% of the respondents said SAS will account for the majority of their disk drive purchases over the next year, although Serial ATA (SATA) topped the list with 37% of the respondents, followed by Fibre Channel with 32%. Only 4% of the poll respondents cited the aging parallel SCSI interface (see figure). However, surveys of InfoStor’s readers are skewed by the fact that almost half of our readers are in the channel (primarily VARs and systems/storage integrators), and the channel moves faster than end users in terms of adopting (or at least kicking the tires on) new technologies such as serial interfaces. Click here to enlarge image To get a more accurate view of the pace of adoption of serial interfaces such as SAS, consider market research predictions from firms such as Gartner and International Data Corp. (IDC). Yet even in those firms’ predictions, SAS is coming on surprisingly strong, mostly at the expense of its parallel SCSI predecessor. For example, Gartner predicts SAS disk drives will account for 16.4% of all multi-user drive shipments this year and will garner almost 45% of the overall market in 2009 (see figure on p. 18).
    [Show full text]
  • AMD Opteron™ Shared Memory MP Systems Ardsher Ahmed Pat Conway Bill Hughes Fred Weber Agenda
    AMD Opteron™ Shared Memory MP Systems Ardsher Ahmed Pat Conway Bill Hughes Fred Weber Agenda • Glueless MP systems • MP system configurations • Cache coherence protocol • 2-, 4-, and 8-way MP system topologies • Beyond 8-way MP systems September 22, 2002 Hot Chips 14 2 AMD Opteron™ Processor Architecture DRAM 5.3 GB/s 128-bit MCT CPU SRQ XBAR HT HT HT 3.2 GB/s per direction 3.2 GB/s per direction @ 0+]'DWD5DWH @ 0+]'DWD5DWH 3.2 GB/s per direction @ 0+]'DWD5DWH HT = HyperTransport™ technology September 22, 2002 Hot Chips 14 3 Glueless MP System DRAM DRAM MCT CPU MCT CPU SRQ SRQ non-Coherent HyperTransport™ Link XBAR XBAR HT I/O I/O I/O HT cHT cHT cHT cHT Coherent HyperTransport ™ cHT cHT I/O I/O HT HT cHT cHT XBAR XBAR CPU MCT CPU MCT SRQ SRQ HT = HyperTransport™ technology DRAM DRAM September 22, 2002 Hot Chips 14 4 MP Architecture • Programming model of memory is effectively SMP – Physical address space is flat and fully coherent – Far to near memory latency ratio in a 4P system is designed to be < 1.4 – Latency difference between remote and local memory is comparable to the difference between a DRAM page hit and a DRAM page conflict – DRAM locations can be contiguous or interleaved – No processor affinity or NUMA tuning required • MP support designed in from the beginning – Lower overall chip count results in outstanding system reliability – Memory Controller and XBAR operate at the processor frequency – Memory subsystem scale with frequency improvements September 22, 2002 Hot Chips 14 5 MP Architecture (contd.) • Integrated Memory Controller
    [Show full text]
  • Gen 6 Fibre Channel Technology
    WHITE PAPER Better Performance, Better Insight for Your Mainframe Storage Network with Brocade Gen 6 TABLE OF CONTENTS Brocade and the IBM z Systems IO product team share a unique Overview .............................................................. 1 history of technical development, which has produced the world’s most Technology Highlights .................................. 2 advanced mainframe computing and storage systems. Brocade’s Gen 6 Fibre Channel Technology technical heritage can be traced to the late 1980s, with the creation of Benefits for z Systems and Flash channel extension technologies to extend data centers beyond the “glass- Storage ................................................................ 7 house.” IBM revolutionized the classic “computer room” with the invention Summary ............................................................. 9 of the original ESCON Storage Area Network (SAN) of the 1990s, and, in the 2000s, it facilitated geographically dispersed FICON® storage systems. Today, the most compelling innovations in mainframe storage networking technology are the product of this nearly 30-year partnership between Brocade and IBM z Systems. As the flash era of the 2010s disrupts between the business teams allows both the traditional mainframe storage organizations to guide the introduction networking mindset, Brocade and of key technologies to the market place, IBM have released a series of features while the integration between the system that address the demands of the data test and qualification teams ensures the center. These technologies leverage the integrity of those products. Driving these fundamental capabilities of Gen 5 and efforts are the deep technical relationships Gen 6 Fibre Channel, and extend them to between the Brocade and IBM z Systems the applications driving the world’s most IO architecture and development teams, critical systems.
    [Show full text]
  • Architecture and Application of Infortrend Infiniband Design
    Architecture and Application of Infortrend InfiniBand Design Application Note Version: 1.3 Updated: October, 2018 Abstract: Focusing on the architecture and application of InfiniBand technology, this document introduces the architecture, application scenarios and highlights of the Infortrend InfiniBand host module design. Infortrend InfiniBand Host Module Design Contents Contents ............................................................................................................................................. 2 What is InfiniBand .............................................................................................................................. 3 Overview and Background .................................................................................................... 3 Basics of InfiniBand .............................................................................................................. 3 Hardware ....................................................................................................................... 3 Architecture ................................................................................................................... 4 Application Scenarios for HPC ............................................................................................................. 5 Current Limitation .............................................................................................................................. 6 Infortrend InfiniBand Host Board Design ............................................................................................
    [Show full text]
  • USB Software Package for Infiniivision X-Series Oscilloscopes
    USB Software Package for InfiniiVision X-Series Oscilloscopes The USB Software Package for Keysight’s InfiniiVision oscilloscopes enables USB 2.0 low-, full-, and hi-speed protocol triggering and decode, as well as USB PD (Power Delivery) trigger and decode. This package also enables other advanced analysis capabilities including USB 2.0 automated signal quality testing, jitter analysis, mask testing, and frequency response analysis (Bode plots) to help test and debug high-speed digital signals, such as USB 2.0. Find us at www.keysight.com Page 1 Table of Contents Introduction ................................................................................................................................................................ 3 Serial Trigger and Decode ......................................................................................................................................... 4 USB 2.0 Low- and Full-speed .................................................................................................................................... 4 USB 2.0 Hi Speed ...................................................................................................................................................... 6 USB PD (Power Delivery) .......................................................................................................................................... 7 Advanced Analysis ...................................................................................................................................................
    [Show full text]
  • FICON Native Implementation and Reference Guide
    Front cover FICON Native Implementation and Reference Guide Architecture, terminology, and topology concepts Planning, implemention, and migration guidance Realistic examples and scenarios Bill White JongHak Kim Manfred Lindenau Ken Trowell ibm.com/redbooks International Technical Support Organization FICON Native Implementation and Reference Guide October 2002 SG24-6266-01 Note: Before using this information and the product it supports, read the information in “Notices” on page vii. Second Edition (October 2002) This edition applies to FICON channel adaptors installed and running in FICON native (FC) mode in the IBM zSeries procressors (at hardware driver level 3G) and the IBM 9672 Generation 5 and Generation 6 processors (at hardware driver level 26). © Copyright International Business Machines Corporation 2001, 2002. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . vii Trademarks . viii Preface . ix The team that wrote this redbook. ix Become a published author . .x Comments welcome. .x Chapter 1. Overview . 1 1.1 How to use this redbook . 2 1.2 Introduction to FICON . 2 1.3 zSeries and S/390 9672 G5/G6 I/O connectivity. 3 1.4 zSeries and S/390 FICON channel benefits . 5 Chapter 2. FICON topology and terminology . 9 2.1 Basic Fibre Channel terminology . 10 2.2 FICON channel topology. 12 2.2.1 Point-to-point configuration . 14 2.2.2 Switched point-to-point configuration . 15 2.2.3 Cascaded FICON Directors configuration. 16 2.3 Access control. 18 2.4 Fibre Channel and FICON terminology.
    [Show full text]
  • 单端模拟输入/输出和 S/Pdif的立体声音频编解码器 查询样品: Pcm2906c
    PCM2906C www.ti.com.cn ZHCS074 –NOVEMBER 2011 具有USB 接口、单端模拟输入/输出和 S/PDIF的立体声音频编解码器 查询样品: PCM2906C 1特性 • 立体声 DAC: 上的模拟性能 234• 片载 USB 接口: – VBUS = 5V: – 具有全速收发器 – THD+N = 0.005% – 完全符合 USB 2.0 规范 – SNR = 96 dB – 由 USB-IF 认证 – 动态范围 = 93 dB – 用于回放的 USB 自适应模式 – 过采样数字滤波器: – 用于记录的 USB 异步模式 – 通频带纹波 = ±0.1 dB – 总线供电 – 阻带衰减 = –43 dB • 16 位 Δ-Σ ADC 和 DAC – 单端电压输出 • 采样速率: – 包含模拟 LPF – DAC: 32,44.1,48 kHz • 多功能: – ADC: – 人机接口 (HID) 功能: 8,11.025,16,22.05,32,44.1,48 kHz – 音量控制和静音 • 具有单个 12-MHz 时钟源的片载时钟发生器 – 终止标识功能 • S/PDIF 输入/输出 • 28-引脚 SSOP 封装 • 单电源: 应用 – 5 V 典型值 (VBUS) • 立体声 ADC: • USB 音频扬声器 • USB 耳机 – VBUS 时的模拟性能 = 5V: – THD+N = 0.01% • USB 显示器 – SNR = 89 dB • USB 音频接口盒 动态范围 – = 89 dB 说明 – 数字抽取滤波器: PCM2906C 是德州仪器的含有一个USB兼容全速协议 – 通频带纹波 = ±0.05 dB 控制器和S/PDIF的单片,USB,立体声编码器。 USB – 阻带衰减 = –65 dB 协议控制器无需软件编码。 PCM2906C 采用 SpAct™ – 单端电压输入 架构,这是 TI 用于从 USB 数据包数据恢复音频时钟 – 包含抗混淆滤波器 的独特系统。 采用SpAct 的片载模拟PLL支持具有低 – 包含数字 HPF 时钟抖动以及独立回放和录音采样率的回放和录音。 1 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. 2SpAct is a trademark of Texas Instruments. 3System Two, Audio Precision are trademarks of Audio Precision, Inc. 4All other trademarks are the property of their respective owners. PRODUCTION DATA information is current as of publication date. Copyright © 2011, Texas Instruments Incorporated Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not English Data Sheet: SBFS037 necessarily include testing of all parameters.
    [Show full text]
  • Serial Attached SCSI (SAS)
    Storage A New Technology Hits the Enterprise Market: Serial Attached SCSI (SAS) A New Interface Technology Addresses New Requirements Enterprise data access and transfer demands are no longer driven by advances in CPU processing power alone. Beyond the sheer volume of data, information routinely consists of rich content that increases the need for capacity. High-speed networks have increased the velocity of data center activity. Networked applications have increased the rate of transactions. Serial Attached SCSI (SAS) addresses the technical requirements for performance and availability in these more I/O-intensive, mission-critical environments. Still, IT managers are pressed on the other side by cost constraints and the need White paper for flexibility and scalability in their systems. While application requirements are the first measure of a storage technology, systems based on SAS deliver on this second front as well. Because SAS is software compatible with Parallel SCSI and is interoperable with Serial ATA (SATA), SAS technology offers the ability to manage costs by staging deployment and fine-tuning a data center’s storage configuration on an ongoing basis. When presented in a small form factor (SFF) 2.5” hard disk drive, SAS even addresses the increasingly important facility considerations of space, heat, and power consumption in the data center. The backplanes, enclosures and cabling are less cumbersome than before. Connectors are smaller, cables are thinner and easier to route impeding less airflow, and both SAS and SATA HDDs can share a common backplane. White paper Getting this new technology to the market in a workable, compatible fashion takes various companies coming together.
    [Show full text]