Principles of Chromatography
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Gas Chromatography-Mass Spectroscopy
Gas Chromatography-Mass Spectroscopy Introduction Gas chromatography-mass spectroscopy (GC-MS) is one of the so-called hyphenated analytical techniques. As the name implies, it is actually two techniques that are combined to form a single method of analyzing mixtures of chemicals. Gas chromatography separates the components of a mixture and mass spectroscopy characterizes each of the components individually. By combining the two techniques, an analytical chemist can both qualitatively and quantitatively evaluate a solution containing a number of chemicals. Gas Chromatography In general, chromatography is used to separate mixtures of chemicals into individual components. Once isolated, the components can be evaluated individually. In all chromatography, separation occurs when the sample mixture is introduced (injected) into a mobile phase. In liquid chromatography (LC), the mobile phase is a solvent. In gas chromatography (GC), the mobile phase is an inert gas such as helium. The mobile phase carries the sample mixture through what is referred to as a stationary phase. The stationary phase is usually a chemical that can selectively attract components in a sample mixture. The stationary phase is usually contained in a tube of some sort called a column. Columns can be glass or stainless steel of various dimensions. The mixture of compounds in the mobile phase interacts with the stationary phase. Each compound in the mixture interacts at a different rate. Those that interact the fastest will exit (elute from) the column first. Those that interact slowest will exit the column last. By changing characteristics of the mobile phase and the stationary phase, different mixtures of chemicals can be separated. -
Assessment of Energetic Heterogeneity of Reversed-Phase
Seton Hall University eRepository @ Seton Hall Seton Hall University Dissertations and Theses Seton Hall University Dissertations and Theses (ETDs) Spring 5-15-2018 Assessment of Energetic Heterogeneity of Reversed-Phase Surfaces Using Excess Adsorption Isotherms for HPLC Column Characterization Leih-Shan Yeung [email protected] Follow this and additional works at: https://scholarship.shu.edu/dissertations Part of the Analytical Chemistry Commons Recommended Citation Yeung, Leih-Shan, "Assessment of Energetic Heterogeneity of Reversed-Phase Surfaces Using Excess Adsorption Isotherms for HPLC Column Characterization" (2018). Seton Hall University Dissertations and Theses (ETDs). 2527. https://scholarship.shu.edu/dissertations/2527 Assessment of Energetic Heterogeneity of Reversed- Phase Surfaces Using Excess Adsorption Isotherms for HPLC Column Characterization By: Leih-Shan Yeung Dissertation submitted to the Department of Chemistry and Biochemistry of Seton Hall University In partial fulfilment of the requirements for the degree of Doctor of Philosophy In Chemistry May 2018 South Orange, New Jersey © 2018 (Leih Shan Yeung) We certify that we have read this dissertation and that, in our opinion, it is adequate in scientific scope and quality as a dissertation for the degree of Doctor of Philosophy. Approved Research Mentor Nicholas H. Snow, Ph.D. Member of Dissertation Committee Alexander Fadeev, Ph.D. Member of Dissertation Committee Cecilia Marzabadi, Ph.D. Chair, Department of Chemistry and Biochemistry Abstract This research is to explore a more general column categorization method using the test attributes in alignment with the common mobile phase components. As we know, the primary driving force for solute retention on a reversed-phase surface is hydrophobic interaction, thus hydrophobicity of the column will directly affect the analyte retention. -
22 Chromatography and Mass Spectrometer
MODULE Chromatography and Mass Spectrometer Biochemistry 22 Notes CHROMATOGRAPHY AND MASS SPECTROMETER 22.1 INTRODUCTION We know that the biochemistry or biological chemistry deals with the study of molecules present in organisms. These molecules are called as biomolecules and they form the basic unit of every cell. These include carbohydrates, proteins, lipids and nucleic acids. To study the biomolecules and to know their function, they have to be obtained in purified form. Purification of the biomolecules includes many physical and chemical methods. This topic gives about two of the commonly used methods namely, chromatography and mass spectrometry. These methods deals with purification and separation of biomolecules namely, protein and nucleic acids. OBJECTIVES After reading this lesson, you will be able to: z define the chromatography and mass spectrometry z describe the principle and important types of chromatographic methods z describe the principle and components of a mass spectrometer z enlist types of mass spectrometer z describe various uses of mass spectrometry 22.2 CHROMATOGRAPHY When we have a mixture of colored small beads, it is easily separated by visual examination. The same holds true for many chemical molecules. In 1903, 280 BIOCHEMISTRY Chromatography and Mass Spectrometer MODULE Mikhail, a botanist (person studies plants) described the separation of leaf Biochemistry pigments (different colors) in solution by using solid adsorbents. He named this method of separation called chromatography. It comes from two Greek words: chroma – colour graphein – to write/detect Modern separation methods are based on different types of chromatographic methods. The basic principle of any chromatography is due to presence of two Notes phases: z Mobile phase – substances to be separated are mixed with this fluid; it may be gas or liquid; it continues moves through the chromatographic instrument z Stationary phase – it does not move; it is packed inside a column; it is a porous matrix that helps in separation of substances present in sample. -
Comprehensive Two-Dimensional Liquid Chromatography - Practical Impacts of Theoretical Considerations
Cent. Eur. J. Chem. • 10(3) • 2012 • 844-875 DOI: 10.2478/s11532-012-0036-z Central European Journal of Chemistry Comprehensive Two-Dimensional Liquid Chromatography - practical impacts of theoretical considerations. A review. Review Article Pavel Jandera Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Pardubice 532 10, Czech Republic Received 24 October 2011; Accepted 31 January 2012 Abstract: A theory of comprehensive two-dimensional separations by liquid chromatographic techniques is overviewed. It includes heart-cutting and comprehensive two-dimensional separation modes, with attention to basic concepts of two-dimensional separations: resolution, peak capacity, efficiency, orthogonality and selectivity. Particular attention is paid to the effects of sample structure on the retention and advantages of a multi-dimensional HPLC for separation of complex samples according to structural correlations. Optimization of 2D separation systems, including correct selection of columns, flow-rate, fraction volumes and mobile phase, is discussed. Benefits of simultaneous programmed elution in both dimensions of LCxLC comprehensive separations are shown. Experimental setup, modulation of the fraction collection and transfer from the first to the second dimension, compatibility of mobile phases in comprehensive LCxLC, 2D asymmetry and shifts in retention under changing second-dimension elution conditions, are addressed. Illustrative practical examples of comprehensive LCxLC separations are shown. Keywords: -
Coupling Gas Chromatography to Mass Spectrometry
Coupling Gas Chromatography to Mass Spectrometry Introduction The suite of gas chromatographic detectors includes (roughly in order from most common to the least): the flame ionization detector (FID), thermal conductivity detector (TCD or hot wire detector), electron capture detector (ECD), photoionization detector (PID), flame photometric detector (FPD), thermionic detector, and a few more unusual or VERY expensive choices like the atomic emission detector (AED) and the ozone- or fluorine-induce chemiluminescence detectors. All of these except the AED produce an electrical signal that varies with the amount of analyte exiting the chromatographic column. The AED does that AND yields the emission spectrum of selected elements in the analytes as well. Another GC detector that is also very expensive but very powerful is a scaled down version of the mass spectrometer. When coupled to a GC the detection system itself is often referred to as the mass selective detector or more simply the mass detector. This powerful analytical technique belongs to the class of hyphenated analytical instrumentation (since each part had a different beginning and can exist independently) and is called gas chromatograhy/mass spectrometry (GC/MS). Placed at the end of a capillary column in a manner similar to the other GC detectors, the mass detector is more complicated than, for instance, the FID because of the mass spectrometer's complex requirements for the process of creation, separation, and detection of gas phase ions. A capillary column is required in the chromatograph because the entire MS process must be carried out at very low pressures (~10-5 torr) and in order to meet this requirement a vacuum is maintained via constant pumping using a vacuum pump. -
Four Channel Liquid Chromatography/Electrochemistry
Four Channel Liquid Chromatography/Electrochemistry Bruce Peary Solomon, Ph.D. The new epsilon family of electrochemical detectors from BAS can Hong Long, Ph.D. Yongxin Zhu, Ph.D. control up to four working electrodes simultaneously. There are several Chandrani Gunaratna, Ph.D. advantages to using multiple detector electrodes. By using four different Lou Coury, Ph.D.* applied potentials with electrodes placed in a parallel arrangement, a Bioanalytical Systems, Inc. hydrodynamic voltammogram can be generated quickly through Corporate R&D Laboratories 2701 Kent Avenue acquisition of four data points for every analyte injection. This speeds West Lafayette, IN method development time. In addition, co-eluting compounds in complex 47906-1382 mixtures can be resolved on the basis of their observed half-wave * corresponding author potentials by using the same arrangement of electrodes, also in parallel. This article presents a few examples of four-electrode experiments performed with epsilon detectors in the BAS R&D labs during the past few months, using both radial-flow and cross-flow thin-layer configurations. The epsilon Platform the past fifteen years, our contract These instruments are fully network- research division, BAS Analytics, able and will be upgradable over the BAS developed and introduced the has provided analytical data of the Internet. New techniques and fea- first commercial electrochemical de- highest quality to the world’s leading tures may initially be ordered àla tector for liquid chromatography pharmaceutical companies using carte, or added at any time when the over twenty-five years ago. With this state-of-the-art products from BAS, need arises. In the coming months, issue of Current Separations,BAS as well as other leading vendors. -
Chapter 15 Liquid Chromatography
Chapter 15 Liquid Chromatography Problem 15.1: Albuterol (a drug used to fight asthma) has a lipid:water KOW (see “Profile—Other Applications of Partition Coefficients”) value of 0.019. How many grams of albuterol would remain in the aqueous phase if 0.001 grams of albuterol initially in a 100 mL aqueous solution were allowed to come into equilibrium with 100 mL of octanol? C (aq) ⇌ C (org) Initial (g) 0.001 g 0 Change -y +y Equil 0.001-y y 푦 100 푚퐿 퐾푂푊 = 0.019 = (0.001−푦) ⁄100푚퐿 1.9 x 10-5 – 0.019y = y 1.019y = 1.9 x 10-5 y = 1.864x10-5 g albuterol would be in the octanol layer Problem 15.2: (a) Repeat Problem 15.1, but instead of extracting the albuterol with 100 mL of octanol, extract the albuterol solution five successive times with only 20 mL of octanol per extraction. After each step, use the albuterol remaining in the aqueous phase from the previous step as the starting quantity for the next step. (Note: the total volume of octanol is the same in both extractions). (b) Compare the final concentration of aqueous albuterol to that obtained in Problem 15.1. Discuss how the extraction results changed by conducting five smaller extractions instead of one large one. What is the downside to the multiple smaller volume method in this exercise compared to the single larger volume method in Problem 15.1? 푦 (a) Each step will have this general form of calculation: 퐾 = 20 푚퐿 푂푊 (푔푖푛푖푡−푦) ⁄100푚퐿 (퐾 )(푔 ) so we can calculate the g transferred to octanol from 푦 = 푂푊 푖푛푖푡 5+퐾푂푊 We can use a spreadsheet to calculate the successive steps: First extraction: -
Triple-Detection Size-Exclusion Chromatography of Membrane Proteins
Triple-Detection Size-Exclusion Chromatography of Membrane Proteins vom Fachbereich Biologie der Technischen Universit¨atKaiserslautern zur Erlangung des akademischen Grades Doktor der Naturwissenschaften (Doctor rerum naturalium; Dr. rer. nat.) genehmigte Dissertation von Frau Dipl.-Biophys. Katharina Gimpl Vorsitzende: Prof. Dr. rer. nat. Nicole Frankenberg-Dinkel 1. Gutachter: Prof. Dr. rer. nat. Sandro Keller 2. Gutachter: Prof. Dr. rer. nat. Rolf Diller Wissenschaftliche Aussprache: 08. April 2016 D 386 Abstract Membrane proteins are generally soluble only in the presence of detergent micelles or other membrane-mimetic systems, which renders the determination of the protein's mo- lar mass or oligomeric state difficult. Moreover, the amount of bound detergent varies drastically among different proteins and detergents. However, the type of detergent and its concentration have a great influence on the protein's structure, stability, and func- tionality and the success of structural and functional investigations and crystallographic trials. Size-exclusion chromatography, which is commonly used to determine the molar mass of water-soluble proteins, is not suitable for detergent-solubilised proteins because the protein{detergent complex has a different conformation and, thus, commonly exhibits a different migration behaviour than globular standard proteins. Thus, calibration curves obtained with standard proteins are not useful for membrane-protein analysis. However, the combination of size-exclusion chromatography with ultraviolet absorbance, -
9.2.3.7 Retention Parameters in Column Chromatography
9.2.3.7 Retention Parameters in Column Chromatography Retention parameters may be measured in terms of chart distances or times, as well as mobile phase volumes; e.g., tR' (time) is analogous to VR' (volume). If recorder speed is constant, the chart distances are directly proportional to the times; similarly if the flow rate is constant, the volumes are directly proportional to the times. Note: In gas chromatography, or in any chromatography where the mobile phase expands in the column, VM, VR and VR' represent volumes under column outlet pressure. If Fc, the carrier gas flow rate at the column outlet and corrected to column temperature (see Flow Rate), is used in calculating the retention volumes from the retention time values, these correspond to volumes at column temperatures. The various conditions under which retention volumes (times) are expressed are indicated by superscripts: thus, a prime ('; as in VR') refers to correction for the hold-up volume (and time) while a circle (º; as in VRº) refers to correction for mobile-phase compression. In the case of the net retention volume (time) both corrections should be applied: however, in order not to confuse the symbol by the use of a double superscript, a new symbol (VN, tN) is used for the net retention volume (time). Hold-up Volume (Time) (VM, tM ) The volume of the mobile phase (or the corresponding time) required to elute a component the concentration of which in the stationary phase is negligible compared to that in the mobile phase. In other words, this component is not retained at all by the stationary phase. -
Studies on the Interaction of Surfactants and Neutral
________________________________________________________ Alma Mater Studiorum – Università di Bologna DOTTORATO DI RICERCA IN SCIENZE FARMACEUTICHE Ciclo XXI Settore scientifico disciplinare di afferenza: CHIM/08 STUDIES ON THE INTERACTION OF SURFACTANTS AND NEUTRAL CYCLODEXTRINS BY CAPILLARY ELECTROPHORESIS. APPLICATION TO CHIRAL ANALYSIS. Dott.ssa Claudia Bendazzoli Coordinatore Dottorato Relatore Prof. Maurizio Recanatini Prof. Roberto Gotti Esame finale anno 2009 ________________________________________________________ “Quando il saggio indica la luna, lo stolto guarda il dito.” (proverbio cinese) ________________________________________________________ To my Mum ________________________________________________________ Table of Contents: Preface (pag.8-9) Chapter 1:Sodium DodecylSulfate and Critical Micelle Concentration • Introduction (pag.11-16) Structure of a Micelle Dynamic properties of surfactants solution • SDS: determination of critical micelle concentration by CE (pag.16-17) • Methodologicalapproaches (pag.18-25) Method based on the retention model—micellar electrokinetic chromatography method Method based on the mobility model—capillary electrophoresis (mobility) method Practical requirements for making critical micelle concentration measurements: micellar electrokinetic chromatography method and capillary electrophoresis (mobility) method • Method based on the measurements of electric current using capillary electrophoresis instrumentation- capillary electrophoresis (current) method (pag.26-28) Practical requirements -
Complexometric Titration and Atomic Emission Spectroscopy) That Allow Us to Quantify the Amount of Each Metal Present Individually
Title Quantitative Analysis of a Solution Containing Cobalt and Copper Name Manraj Gill (Lab partner: Tanner Adams) Abstract In this series of experiments, we determine the concentrations of two metal species, copper and cobalt, in a mixture of the two by initially using an ion exchange column to separate them from the mixture. We consequently use two different techniques (complexometric titration and atomic emission spectroscopy) that allow us to quantify the amount of each metal present individually. This step-by-step analysis not only goes through the basis for the experimental approach but also is a breakdown of the measurements that leads us to the final results: the Co:Cu ratio in the unknown mixture. Purpose In this series of three experiments (Parts I – III), we aim to initially separate a solution containing a mixture of Cobalt, Co (II), and Copper, Cu (II), ions in an unknown ratio and in unknown concentrations. The end goal of the entire experiment is to determine how much Co and Cu were originally present in the sample we obtained in Part I. But to do so, as explained in further detail in the ‘Theory and Methods’ section below, we initially separate the two ions (Part I) based on their unique chemical properties and then we attempt to quantify the separated ions through two different methods (Parts II, III). The overall purpose is an analysis of the efficiency of the separation and quantification approaches used to measure the constituent compounds in a mixture. This “efficiency” can be determined by comparing the obtained measurements to the known amounts that were used to make the solution. -
Solubility and Distribution Phenomena Solubility Definitions
Solubility and Distribution Phenomena Solubility definitions • Solubility is: • the concentration of solute in a saturated solution at a certain temperature, • the spontaneous interaction of two or more substances to form a homogeneous molecular dispersion. • Solubility is an intrinsic material property that can be altered only by chemical modification of the molecule. • the solubility of a compound depends on: 1. the physical and chemical properties of the solute and the solvent 2. temperature, pressure, the pH of the solution, • The term miscibility refers to the mutual solubility of the components in liquid–liquid systems. • The equilibrium involves a balance of the energy of three interactions against each other: • (1) solvent with solvent, • (2) solute with solute, • (3) solvent and solute. • Thermodynamic equilibrium is achieved when the overall lowest energy state of the system is achieved. Solubility Expressions • The United States Pharmacopeia (USP): • describes the solubility of drugs as parts of solvent required for one part solute. • Solubility is also quantitatively expressed in terms of molality, molarity, and percentage. • For exact solubilities of many substances: official compendia (e.g., USP) and the Merck Index. Solvent–Solute Interactions • “like dissolves like.” 1. Polar Solvents 2. Nonpolar Solvents 3. Semipolar Solvents Polar Solvents • dissolve ionic solutes and other polar substances. • reduce the attraction between the ions of strong and weak electrolytes because of the solvents' high dielectric constants. • Water dissolves sugars, phenols, alcohols, aldehydes, ketones, amines, and other oxygen- and nitrogen-containing compounds that can form hydrogen bonds with water: • As the length of a nonpolar chain of an aliphatic alcohol increases, the solubility of the compound in water decreases.