High Performance Flat Plate Solar Thermal Collector Evaluation
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Investigation of the Impact of Commercial Building Envelope Airtightness on HVAC Energy Use
NISTIR 7238 Investigation of the Impact of Commercial Building Envelope Airtightness on HVAC Energy Use Steven J. Emmerich Tim McDowell Wagdy Anis NISTIR 7238 Investigation of the Impact of Commercial Building Envelope Airtightness on HVAC Energy Use Steven J. Emmerich Building and Fire Research Laboratory Timothy P. McDowell TESS, Inc. Wagdy Anis Shepley Bulfinch Richardson and Abbott Prepared for: U.S. Department of Energy Office of Building Technologies June 2005 U.S. Department of Commerce Carlos M. Gutierrez, Secretary Technology Administration Phillip J. Bond, Under Secretary of Commerce for Technology National Institute of Standards and Technology Hratch Semerjian, Acting Director ABSTRACT This report presents a simulation study of the energy impact of improving envelope airtightness in U.S. commercial buildings. Despite common assumptions, measurements have shown that typical U.S. commercial buildings are not particularly airtight. Past simulation studies have shown that commercial building envelope leakage can result in significant heating and cooling loads. To evaluate the potential energy savings of an effective air barrier requirement, annual energy simulations were prepared for three nonresidential buildings (a two-story office building, a one-story retail building, and a four-story apartment building) in 5 U.S. cities. A coupled multizone airflow and building energy simulation tool was used to predict the energy use for the buildings at a target tightness level relative to a baseline level based on measurements in existing buildings. Based on assumed blended national average heating and cooling energy prices, predicted potential annual heating and cooling energy cost savings ranged from 3 % to 36 % with the smallest savings occurring in the cooling-dominated climates of Phoenix and Miami. -
Solar Energy: State of the Art
Downloaded from orbit.dtu.dk on: Sep 27, 2021 Solar energy: state of the art Furbo, Simon; Shah, Louise Jivan; Jordan, Ulrike Publication date: 2003 Document Version Publisher's PDF, also known as Version of record Link back to DTU Orbit Citation (APA): Furbo, S., Shah, L. J., & Jordan, U. (2003). Solar energy: state of the art. BYG Sagsrapport No. SR 03-14 General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim. Editors: Simon Furbo Louise Jivan Shah Ulrike Jordan Solar Energy State of the art DANMARKS TEKNISKE UNIVERSITET Internal Report BYG·DTU SR-03-14 2003 ISSN 1601 - 8605 Solar Energy State of the art Editors: Simon Furbo Louise Jivan Shah Ulrike Jordan Department of Civil Engineering DTU-bygning 118 2800 Kgs. Lyngby http://www.byg.dtu.dk 2003 PREFACE In June 2003 the Ph.D. course Solar Heating was carried out at Department of Civil Engineering, Technical University of Denmark. -
Infiltration Modeling Guidelines for Commercial Building Energy Analysis
PNNL-18898 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 DOCKET 12-BSTD-1 DATE RECD. MAY 15 2012 Infiltration Modeling Guidelines for Commercial Building Energy Analysis K Gowri D Winiarski R Jarnagin September 2009 ii Executive Summary This report presents a methodology for modeling air infiltration in EnergyPlus to account for envelope air barrier characteristics. Based on a review of various infiltration modeling options available in EnergyPlus and sensitivity analysis, the linear wind velocity coefficient based on DOE-2 infiltration model is recommended. The methodology described in this report can be used to calculate the EnergyPlus infiltration input for any given building level infiltration rate specified at known pressure difference. The sensitivity analysis shows that EnergyPlus calculates the wind speed based on zone altitude, and the linear wind velocity coefficient represents the variation in infiltration heat loss consistent with building location and weather data. EnergyPlus infiltration input is calculated to be 0.2016 cfm/sf of exterior wall area, assuming that uncontrolled air leakage through the building envelope can be specified by a baseline leakage rate of 1.8 cfm/sf (@ 0.30 in. w.c) of exterior above grade envelope area (based on ASHRAE SSPC-90.1 Envelope Subcommittee recommendation). iii Contents 1. Introduction ................................................................................................................................ 4 2. Building Infiltration Rate ........................................................................................................... -
GRID-INTERACTIVE EFFICIENT BUILDINGS TECHNICAL REPORT SERIES: Overview of Research Challenges and Gaps
Grid-interactive Efficient Buildings Technical Report Series Overview of Research Challenges and Gaps December 2019 (This page intentionally left blank) GRID-INTERACTIVE EFFICIENT BUILDINGS TECHNICAL REPORT SERIES: Overview of Research Challenges and Gaps Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government, nor any agency thereof, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency, contractor, or subcontractor thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. iii GRID-INTERACTIVE EFFICIENT BUILDINGS TECHNICAL REPORT SERIES: Overview of Research Challenges and Gaps Authors The authors of this report are: Monica Neukomm, U.S. Department of Energy (DOE) Valerie Nubbe, Navigant Consulting, Inc. Robert Fares, former American Association for the Advancement of Science (AAAS) fellow at DOE Acknowledgments The authors would like to acknowledge the valuable guidance and input provided during the preparation of this report. The authors are also grateful to the following list of contributors. Their feedback, guidance, and review proved invaluable in preparing this report. -
A Review of Building Integrated Solar Thermal (Bist)
enewa f R bl o e ls E a n t e n r e g Journal of y m a a n d d Zhang et al., n u A J Fundam Renewable Energy Appl 2015, 5:5 F p f p Fundamentals of Renewable Energy o l i l ISSN: 2090-4541c a a DOI: 10.4172/2090-4541.1000182 n t r i o u n o s J and Applications Review Article Open Access Building Integrated Solar Thermal (BIST) Technologies and Their Applications: A Review of Structural Design and Architectural Integration Xingxing Zhang*1, Jingchun Shen1, Llewellyn Tang*1, Tong Yang1, Liang Xia1, Zehui Hong1, Luying Wang1, Yupeng Wu2, Yong Shi1, Peng Xu3 and Shengchun Liu4 1Department of Architecture and Built Environment, University of Nottingham, Ningbo, China 2Department of Architecture and Built Environment, University of Nottingham, UK 3Beijing Key Lab of Heating, Gas Supply, Ventilating and Air Conditioning Engineering, Beijing University of Civil Engineering and Architecture, China 4Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, China Abstract Solar energy has enormous potential to meet the majority of present world energy demand by effective integration with local building components. One of the most promising technologies is building integrated solar thermal (BIST) technology. This paper presents a review of the available literature covering various types of BIST technologies and their applications in terms of structural design and architectural integration. The review covers detailed description of BIST systems using air, hydraulic (water/heat pipe/refrigerant) and phase changing materials (PCM) as the working medium. The fundamental structure of BIST and the various specific structures of available BIST in the literature are described. -
District Heating System, Which Is More Efficient Than
Supported by ECOHEATCOOL Work package 3 Guidelines for assessing the efficiency of district heating and district cooling systems This report is published by Euroheat & Power whose aim is to inform about district heating and cooling as efficient and environmentally benign energy solutions that make use of resources that otherwise would be wasted, delivering reliable and comfortable heating and cooling in return. The present guidelines have been developed with a view to benchmarking individual systems and enabling comparison with alternative heating/cooling options. This report is the report of Ecoheatcool Work Package 3 The project is co-financed by EU Intelligent Energy Europe Programme. The project time schedule is January 2005-December 2006. The sole responsibility for the content of this report lies with the authors. It does not necessarily reflect the opinion of the European Communities. The European Commission is not responsible for any use that may be made of the information contained therein. Up-to-date information about Euroheat & Power can be found on the internet at www.euroheat.org More information on Ecoheatcool project is available at www.ecoheatcool.org © Ecoheatcool and Euroheat & Power 2005-2006 Euroheat & Power Avenue de Tervuren 300, 1150 Brussels Belgium Tel. +32 (0)2 740 21 10 Fax. +32 (0)2 740 21 19 Produced in the European Union ECOHEATCOOL The ECOHEATCOOL project structure Target area of EU28 + EFTA3 for heating and cooling Information resources: Output: IEA EB & ES Database Heating and cooling Housing statistics -
Net Energy Analysis of a Solar Combi System with Seasonal Thermal Energy Store
Net energy analysis of a solar combi system with Seasonal Thermal Energy Store Colclough, S., & McGrath, T. (2015). Net energy analysis of a solar combi system with Seasonal Thermal Energy Store. Applied Energy, 147, 611-616. https://doi.org/10.1016/j.apenergy.2015.02.088 Published in: Applied Energy Document Version: Peer reviewed version Queen's University Belfast - Research Portal: Link to publication record in Queen's University Belfast Research Portal Publisher rights © Elsevier 2015. This manuscript version is made available under the CC-BY-NC-ND 4.0 license (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits distribution and reproduction for non-commercial purposes, provided the author and source are cited. General rights Copyright for the publications made accessible via the Queen's University Belfast Research Portal is retained by the author(s) and / or other copyright owners and it is a condition of accessing these publications that users recognise and abide by the legal requirements associated with these rights. Take down policy The Research Portal is Queen's institutional repository that provides access to Queen's research output. Every effort has been made to ensure that content in the Research Portal does not infringe any person's rights, or applicable UK laws. If you discover content in the Research Portal that you believe breaches copyright or violates any law, please contact [email protected]. Download date:29. Sep. 2021 Elsevier Editorial System(tm) for Applied Energy Manuscript Draft Manuscript Number: Title: Net Energy analysis of a Solar Combi System with Seasonal Thermal Energy Store Article Type: Original Paper Keywords: Seasonal Thermal Energy Storage; STES; Passive House; Life Cycle Analysis; Net Energy Ratio Corresponding Author: Dr. -
Heating, Cooling, and Ventilation Strategies in Passive House Design
On a Path to Zero Energy Construction: Passive House & Building Workshop Heating, Cooling, and Ventilation Strategies in Passive House Design John Semmelhack www.think-little.com AGENDA o HVAC goals o Heating, Cooling, Dehumidification o Ventilation o Single-family, mixed-humid climate focus HVAC GOALS o We don’t build buildings in order to save energy o Our first job is to provide comfort! o Indoor Air Quality – first, do no harm HEAT – COOL – DEHU AGENDA o PHIUS heating + cooling load standards o Load calculations o Equipment selection o Supplemental dehumidification? o Duct design PHIUS HEATING + COOLING METRICS PHIUS HEATING + COOLING METRICS For a 2,500ft2 house: 10,000 Btu/hr heating load 12,250 Btu/hr cooling load “1-ton” LOAD CALCULATIONS* Why do we do load calcs? * aka “Peak loads” or “Design Loads” LOAD CALCULATIONS Why do we do load calcs? Prior to selecting equipment, we need to know how much heat we need to add or remove in order to maintain comfort during peak/design conditions. We’d like to pick equipment that’s neither too small (bad comfort) nor too big (higher cost and bad comfort) ……but just right! LOAD CALCULATIONS Three loads: 1. Heating 2. Sensible cooling 3. Latent cooling (aka dehumidification) LOAD CALCULATIONS Three loads: 1. Heating 2. Sensible cooling 3. Latent cooling LOAD CALCULATION METHODS Manual J o Room-by-room or block load o Typically uses 1% and 99% ASHRAE design temperatures o Incorporates solar and internal gains for cooling, but not for heating o Thermal mass/lag is accounted for in solar gains. -
Passive House 101
PASSIVE HOUSE 101 An Introduction t o Passive Buildings & D e s i g n AGENDA What is Passive House Passive House Standards & Metrics Design Principles and Features Case Studies and Lessons Learned Can You Find the Passive House? Can You Find the Passive House? Passive House Passive House is a performance-based building certification that focuses on the dramatic reduction of energy use for space heating and cooling Passive House achieves: ● Dramatic reduction in overall energy use ● Dramatic reduction in carbon emissions ● Proven improvement in air quality, health, and occupant comfort ● Greater building durability ● Resilience to major weather events ● Lower operating costs ● Pathway to net-zero Goal: 90% reduction in heating and cooling loads comparted to a typical building Goal: 60-70% reduction in Typical Residential Passive House overall energy use Building comparted to typical buildings Measured Performance: 30-45% less carbon emissions than MA stretch code buildings Source: New Ecology Air Quality, Health, and Comfort Continuous ventilation of filtered air Increased use of non-toxic materials Consistent comfortable room temps Elimination of air drafts Increased natural lighting Quieter acoustic conditions Durability & Resilience Shelter in Place Maintain consistent indoor temps during extreme weather and power outages Durable & Long Lasting Construction Resists mold, rot, pests & water intrusion Passive Not Active Lower reliance on mechanical systems Passive House Examples Rocksbury House Placetailor Design/Build 33.2 EUI Wayland -
Compact Heat Exchangers for Mobile Co2 Systems
COMPACT HEAT EXCHANGERS FOR MOBILE CO2 SYSTEMS A. Hafner SINTEF Energy Research Refrigeration and Air Conditioning Trondheim (Norway) ABSTRACT The natural refrigerant carbon dioxide (CO2) with all its advantages offers new possibilities of efficient heating and cooling at different climates. In reversible air conditioning systems the capacity and efficiency in cooling mode is seen to be most important. The efficiency of the reversible interior heat exchanger depends on the design of the heat exchanger. Efficiency reduction is among other factors caused by refrigerant- side pressure drop, heat conduction, refrigerant- and air maldistribution. Uniform air temperatures at the outlet of the heat exchanger are an important aspect regarding comfort and control of the mobile HVAC system. A prototype CO2 system with a separator, refrigerant pump and a single pass heat exchanger was tested under varies conditions. The tests were performed at low compressor revolution speed i.e. idle conditions. Compared with a baseline heat exchanger of equal size, the use of an external operated pump to circulate the refrigerant through the heat exchanger, increased the cooling capacity at equal pressure levels by up to 14 %. At equal cooling capacities the COP increased by up to 23 %. Airside temperature distribution was more uniform with this way of operating the system. 1 INTRODUCTION Several authors for example Hrnjak et al 2002, Nekså et al. 2001 describe CO2 systems where flash gas was bypassed the evaporator and thereafter reunified with the leaving gas of the evaporator. With such a system concept only liquid refrigerant enters the evaporator which has an positive effect on distribution of the refrigerant into 20000 the microchannels. -
Heat Exchangers Quick Facts
TM WATER HEATERS Heat Exchangers Quick Facts HUBBELLHEATERS.COM What Are They? A heat exchanger is a device that allows thermal energy (heat) from a liquid or gas to pass another fluid without the two fluids mixing. It transfers the heat without transferring the fluid that carries the heat. Therefore, just the heat is exchanged from one fluid to another. This type of heat transfer is utilized with many applications including water heating, sewage treatment, heating and air conditioning, and refrigera- tion. There are several different types of heat exchangers, each with their own design that work to heat up water. Next we will break down some of the key features of commonly used heat exchangers and the differences between them. Plate: A plate heat exchanger consists of a series of metal plates, typically stainless steel, that are joined together with a small amount of space between the face of the plates. The bottom of the plates create a small gutter or channel in between each plate which helps to keep water flowing. The thinner the channel, the more efficient the plates will be at transferring heat to the water because smaller amounts of water can be heated up faster. Plate heat exchangers have a large surface area, so as fluid flows in between these plates, it extracts heat from the plates rather quickly. This design is available as a brazed plate or gasketed design and can be configured as single or double wall. www.hubbellheaters.com Page 1 Electric/Coil: An electric heat exchanger is probably what most people think of when they think “electric heat” It is a simple coil wire that gives off heat like a light bulb in a lamp, and when electricity flows through it, it converts the energy passing through into heat. -
Characterization and Energy Performance of a Slurry PCM-Based Solar Thermal Collector: a Numerical Analysis
View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by PORTO Publications Open Repository TOrino Politecnico di Torino Porto Institutional Repository [Article] Characterization and energy performance of a slurry PCM-based solar thermal collector: a numerical analysis Original Citation: Serale G.; Baronetto S.; Goia F.; Perino M. (2014). Characterization and energy performance of a slurry PCM-based solar thermal collector: a numerical analysis. In: ENERGY PROCEDIA, vol. 48, pp. 223-232. - ISSN 1876-6102 Availability: This version is available at : http://porto.polito.it/2592626/ since: February 2015 Publisher: Elsevier Published version: DOI:10.1016/j.egypro.2014.02.027 Terms of use: This article is made available under terms and conditions applicable to Open Access Policy Article ("Creative Commons: Attribution-Noncommercial-No Derivative Works 3.0") , as described at http: //porto.polito.it/terms_and_conditions.html Porto, the institutional repository of the Politecnico di Torino, is provided by the University Library and the IT-Services. The aim is to enable open access to all the world. Please share with us how this access benefits you. Your story matters. Publisher copyright claim: This is the publisher’s version of a proceedings published on [pin missing: event_title], Publisher [pin missing: publisher], Vol 48 , Number UNSPECIFIED Year 2014 (ISSN epc:pin name ="issn"/> - ISBN [pin missing: isbn] )The present version is accessible on PORTO, the Open Access Repository of the Politecnico of Torino