Frequency Counter 5382A

Total Page:16

File Type:pdf, Size:1020Kb

Frequency Counter 5382A ®_ PER ATING AN® S E R V I C E M A N U A L FREQUENCY COUNTER 5382A HEWLETT ~ PACKARD CERTIFICATION The Hewlett-Packard Company certifies that this instrument was thoroughly tested and inspected and found to meet its published specifications when it was shipped from the factory. The Hewlett- Packard Company further certifies that its calibration measure- ments are traceable to the U.S. National Bureau of Standards to the extent allowed by the Bureau's calibration facility. WARRANTY AND ASSISTANCE This Hewlett-Packard product is warranted against defects in materials and workmanship. This warranty applies for one year from the date of delivery, or, in the case of certain major com- ponents listed in the manual, for the specified period. We will repair or replace products which prove to be defective during the warranty period provided they are returned to Hewlett- Packard. No other warranty is expressed or implied. We are not liable for consequential damages. Service contracts or customer assistance agreements are available for Hewlett-Packard products that require maintenance and repair on-site. For any assistance, contact your nearest Hewlett-Packard Sales and Service Office. FREQUENCY COUNTER 5382A OPERATING AND SERVICE MANUAL SERIAL PREFIX: 1408A This manual applies directly to HP Model 5382A Fre- quency Counters having serial number prefix 1408A. NEWER INSTRUMENTS This manual, with enclosed "Manual Changes" sheet, applies to HP Model 5382A Frequency Counters having serial number prefixes as listed on the "Manual Changes" sheet. Copyright HEWLETT-PACKARD COMPANY 1974 5301 STEVENS CREEK BLVD., SANTA CLARA, CALIF. 95050 Printed: MAY 1974 MANUAL PART NUMBER 05382-90001 MICROFICHE PART NUMBER 05382-90002 PRINTED IN U.S .A. HEWLETT&I PACKARD Model 5382A Table of Contents TABLE OF CONTENTS Section Title Page I GENERAL INFORMATION . 1-1 1-1 . Introduction . 1-1 1-3. Instrument Description . 1-1 1-5. Instrument Identification . 1-1 1-8. Specifications . 1-2 II INSTALLATION AND OPERATION . 2-1 2-1. Introduction . 2-1 2-3. Unpacking and Inspection . 2-1 2-5. Storage and Shipment . 2-1 2-8. Line Voltage Selection . 2-1 2-11. Operation . 2-2 2-13. Cable and Termination Requirements . 2-2 2-15. Ratio Measurements (Standard Counter Only) . 2-2 2-18. Optimizing Noise Rejection . 2-2 III MAINTENANCE . 3-1 3-1. Introduction . 3-1 3-3. Theory of Circuit Operation . 3-1 3-5. Input Circuits . 3-2 3-7. Decade Counter, Latch, and Multiplexer Circuits . 3-2 3-9. Time Base Oscillator and Divider . 3-2 3-14. Display Scanner . 3-2 3-17. Display Blanking Circuits . 3-3 3-20. Reset and Transfer Control Circuits . .. 3-3 3-22. Recommended Test Equipment . 3-3 3-24. In-Cabinet Performance Check . 3-4 3-26. Instrument Access . 3-4 3-28. Preventive Maintenance . 3-6 3-30. General Repair . 3-7 3-34. Adjustments . .. 3-7 3-36. Amplifier Balance Adjustment . 3-7 3-38. Oscillator Adjustment (Standard Unit) . 3-7 3-40. Oscillator Adjustment (Option 001 Unit) . 3-8 3-42. Troubleshooting . 3-8 3-45. Replaceable Parts . 3-8 3-47. Ordering Information . 3-10 3-49. Schematic Diagram . 3-10 Model 5382A List of Tables List of Figures LIST OF TABLES Table Title Page 1-1. Specifications . 1-1 3-1. Recommended Test Equipment . 3-4 3-2. In-Cabinet Performance Check . 3-5 3-3. Replaceable Parts . 3-12 3-4. Manufacturers Code List . 3-15 3-5. Major Signal Definitions . 3-17 LIST OF FIGURES Figure Title Page 1-1. Model 5382A Frequency Counter . 1-1 2-1. Power Cord Connector for 240-Volt Operation . 2-1 2-2. Front-Panel Operating Controls, Connectors, and Indicators . 2-3 2-3. Rear-Panel Operating Controls and Connectors . 2-4 3-1. Simplified Block Diagram . 3-1 3-2. Troubleshooting Flow Chart . 3-9 3-3. Schematic Diagram Notes . 3-16 3-4. Instrument Timing Diagram . 3-18 3-5. Component Locators . 3-19 3-6. Overall Schematic Diagram . 3-21 Model 5382A General Information SECTION 1 GENERAL INFORMATION 1-1 . INTRODUCTION 1-2. This section of the manual gives a description of the instrument, information on instrument identification and available options, and complete specifications. 1-3. INSTRUMENT DESCRIPTION 1-4. The HP Model 5382A Frequency Counter (see Figure 1-1) is a direct-counting frequency counter that has a range of 10 Hz to 225 MHz. Eight display digits are provided . Front-panel controls allow a selection of gate times and attenuation factors of the input signal. A rear-panel connector and associated selector switch allow connection of an external time base oscillator. This feature also allows ratio measurements to be made by the counter. When the optional temperature compensated crystal oscillator is included (Option 001), the switch is not provided and the connector allows external use of the 10 MHz time base oscillator . Refer to Table 1-1 for all counter specifications. 1-5. INSTRUMENT IDENTIFICATION 1-6. Hewlett-Packard uses a 2-section, 10-character serial number (OOOOA00000) mounted on the rear panel to identify the instrument . The first four digits are the serial prefix and the last five digits refer to the specific instrument . The alphabetical character identifies the country of manu- facture. If the serial prefix on your instrument differs from that listed on the title page of this manual, there are differences between the manual and your instrument . Any lower serial pre- fixes are documented separately in this manual, and higher serial prefixes are covered by a manual change sheet included with the manual . 1-7. The printed circuit boards within the instrument are identified by a 2-section, 10-digit part number (e.g., 05382-60001) and a 4-digit series number (e.g., "SERIES 1404"). The series num- ber identifies the electrical characteristics of the complete printed-circuit assembly . A replace- ment circuit-board assembly may have a different series number than the assembly originally supplied with the instrument . Therefore, when troubleshooting a circuit-board assembly, ensure that the series number on the schematic diagram matches the series number on the board assem- bly. If the series number on the assembly is lower than the number on the schematic diagram in Section III, refer to backdating information in this manual for change information. If the series number on the assembly is higher than the number on the schematic diagram, the change infor- mation is provided in a manual change sheet which is available from the nearest Hewlett- Packard Sales and Service Office. Figure 1-1. Model 5382A Frequency Counter Model 5382A General Information 1-8. SPECIFICATIONS 1-9. Table 1-1 lists all specifications of the frequency counter. Table 1-1 . Specifications Frequency Range: 10 Hz to 225 MHz Display: 8 Digit (LEDs) Input Impedance: 1 MQ, <40 pf Sensitivity: 25 mV (rms sinewave) 30 Hz to 10 MHz 50 mV (rms sinewave) 10 Hz to 225 MHz Input Attenuator: Three Position (xl, x10, x100) Maximum Input Levels: DC to 40 Hz 200 V (dc + Peak ac) ATTENUATOR 40 Hz to 100 kHz 250 V rms 14x1" 100 kHz to 5 MHz 2.5 x 107 V Hz >5 MHz 5 V rms DC to 40 Hz 200 V (dc + Peak ac) ATTENUATOR 40 Hz to 1 MHz 250 V rms "x10" 1 MHz to 50 MHz 2.5 x 108 V Hz "x100" 50 MHz to 225 MHz 5 V rms Accuracy: tl Count t Time Base Accuracy Gate Times: Manually Selected .1 second, 1 second, 10 seconds Resolution : 10 Hz at 0.1 second gate time 1 Hz at 1 second gate time 0.1 Hz at 10 second gate time Time Base: Internal Frequency: 10 MHz Crystal Aging: <0.3 ppm/Month Temperature: t2.5 ppm 0°C to 40°C Line Voltage: t0.5 ppm for 10% line variation External Input Frequency Range: 100 kHz to 10 MHz Sensitivity: 250 mV rms 1 KSZ input impedance Maximum Input: 25 V rms do to 10 MHz Operating Temperature: 0°C to 40°C Power Requirements: 100, 120, 220, and 240 V rms (48 Hz to 440 Hz) (+5%-15%) 20 VA max. Weight: Net: 4.75 lb (2,2 kg) Shipping: 6 lb (2,8 kg) Dimensions: 3.5 in. H x 6.25 in. W x 9.75 in. D (89 mm x 160 mm x 248 mm) OPTION 001 Temperature Compensated Crystal Oscillator Frequency: 10 MHz Aging: <1 part in 10'/Month Temperature: t1 ppm 0°C to 40°C Line Voltage: 1 part in 107 for 10% change External input replaced with Oscillator Monitor Output on Option 001 Model 5382A Installation and Operation SECTION 11 INSTALLATION AND OPERATION 2-1. INTRODUCTION 2-2. This section of the manual provides information about unpacking, inspecting, storing, and shipping the frequency counter and gives instructions for operating the counter. Descriptions of all controls, connectors, and indicators are.
Recommended publications
  • The 4 States QRP Group HF Test Set Construction Manual
    Copyright 2006, NB6M - Unauthorized Copying or Publication Prohibited The 4 States QRP Group HF Test Set Construction Manual Containing several key pieces of simple Test Equipment that are used to either test or troubleshoot radio circuitry By Wayne McFee, NB6M Revision 0.2 October 21, 2007 Copyright 2006, NB6M - Unauthorized Copying or Publication Prohibited 1 THE HF TEST SET .....................................................................................................................................3 INTRODUCTION............................................................................................................................................3 HF TEST SET SCHEMATIC ...........................................................................................................................5 BOARD LAYOUT..........................................................................................................................................6 PARTS LIST .................................................................................................................................................7 TOOLS AND EQUIPMENT NEEDED................................................................................................................9 PC BOARD, PARTS SIDE ...........................................................................................................................10 PC BOARD, TRACE SIDE...........................................................................................................................11 STARTING
    [Show full text]
  • Keysight 53147A/148A/149A Microwave Frequency Counter/Power Meter/DVM
    Keysight 53147A/148A/149A Microwave Frequency Counter/Power Meter/DVM Assembly Level Service Guide Notices U.S. Government Rights Warranty The Software is “commercial computer THE MATERIAL CONTAINED IN THIS Copyright Notice software,” as defined by Federal Acqui- DOCUMENT IS PROVIDED “AS IS,” sition Regulation (“FAR”) 2.101. Pursu- AND IS SUBJECT TO BEING © Keysight Technologies 2001 - 2017 ant to FAR 12.212 and 27.405-3 and CHANGED, WITHOUT NOTICE, IN No part of this manual may be repro- Department of Defense FAR Supple- FUTURE EDITIONS. FURTHER, TO THE duced in any form or by any means ment (“DFARS”) 227.7202, the U.S. MAXIMUM EXTENT PERMITTED BY (including electronic storage and government acquires commercial com- APPLICABLE LAW, KEYSIGHT DIS- retrieval or translation into a foreign puter software under the same terms CLAIMS ALL WARRANTIES, EITHER language) without prior agreement and by which the software is customarily EXPRESS OR IMPLIED, WITH REGARD written consent from Keysight Technol- provided to the public. Accordingly, TO THIS MANUAL AND ANY INFORMA- ogies as governed by United States and Keysight provides the Software to U.S. TION CONTAINED HEREIN, INCLUD- international copyright laws. government customers under its stan- ING BUT NOT LIMITED TO THE dard commercial license, which is IMPLIED WARRANTIES OF MER- Manual Part Number embodied in its End User License CHANTABILITY AND FITNESS FOR A 53147-90010 Agreement (EULA), a copy of which can PARTICULAR PURPOSE. KEYSIGHT be found at http://www.keysight.com/ SHALL NOT BE LIABLE FOR ERRORS Edition find/sweula. The license set forth in the OR FOR INCIDENTAL OR CONSE- Edition 3, November 1, 2017 EULA represents the exclusive authority QUENTIAL DAMAGES IN CONNECTION by which the U.S.
    [Show full text]
  • Keysight U1251B and U1252B Handheld Digital Multimeter
    Keysight U1251B and U1252B Handheld Digital Multimeter User’s and Service Guide Notices U.S. Government Rights Warranty The Software is “commercial computer THE MATERIAL CONTAINED IN THIS Copyright Notice software,” as defined by Federal DOCUMENT IS PROVIDED “AS IS,” AND Acquisition Regulation (“FAR”) 2.101. IS SUBJECT TO BEING CHANGED, © Keysight Technologies 2009 – 2019 Pursuant to FAR 12.212 and 27.405-3 WITHOUT NOTICE, IN FUTURE No part of this manual may be and Department of Defense FAR EDITIONS. FURTHER, TO THE reproduced in any form or by any Supplement (“DFARS”) 227.7202, the MAXIMUM EXTENT PERMITTED BY means (including electronic storage U.S. government acquires commercial APPLICABLE LAW, KEYSIGHT and retrieval or translation into a computer software under the same DISCLAIMS ALL WARRANTIES, EITHER foreign language) without prior terms by which the software is EXPRESS OR IMPLIED, WITH REGARD agreement and written consent from customarily provided to the public. TO THIS MANUAL AND ANY Keysight Technologies as governed by Accordingly, Keysight provides the INFORMATION CONTAINED HEREIN, United States and international Software to U.S. government INCLUDING BUT NOT LIMITED TO THE copyright laws. customers under its standard IMPLIED WARRANTIES OF commercial license, which is embodied MERCHANTABILITY AND FITNESS FOR Manual Part Number in its End User License Agreement A PARTICULAR PURPOSE. KEYSIGHT U1251-90036 (EULA), a copy of which can be found at SHALL NOT BE LIABLE FOR ERRORS http://www.keysight.com/find/sweula. OR FOR INCIDENTAL OR Edition The license set forth in the EULA CONSEQUENTIAL DAMAGES IN Edition 24, July 26, 2019 represents the exclusive authority by CONNECTION WITH THE FURNISHING, which the U.S.
    [Show full text]
  • 53200A Series RF/Universal Frequency Counter/Timers
    Keysight Technologies 53200A Series RF/Universal Frequency Counter/Timers Data Sheet Imagine Your Counter Doing More! Introduction Frequency counters are depended on in R&D and in manufacturing for the fastest, most accurate frequency and time interval measurements. The 53200 Series of RF and universal frequency counter/timers expands on this expectation to provide you with the most information, connectivity and new measurement capabilities, while building on the speed and accuracy you’ve depended on with Keysight Technologies, Inc. time and frequency measurement expertise. Three available models offer resolution capabilities up to 12 digits/sec frequency resolution on a one second gate. Single- shot time interval measurements can be resolved down to 20 psec. All models offer new built-in analysis and graphing capabilities to maximize the insight and information you receive. More bandwidth Measurement by model Measurements Model Standard Opt MW Inputs – 350 MHz baseband frequency 350 MHz Input (53210A: Ch 2, – 6 or 15 GHz optional microwave Channel(s) 53220A/30A: Ch 3) channels Frequency 53210A, ● ● More resolution & speed 53220A, – 12 digits/sec 53230A – 20 ps single-shot time resolution Frequency ratio 53210A, ● ● – Up to 75,000 and 90,000 53220A, readings/sec (frequency and 53230A time interval) Period 53210A, ● ● More insight 53220A, 53230A – Datalog trend plot Minimum/maximum/ 53210A, ● – Cumulative histogram peak-to-peak input 53220A, – Built-in math analysis and voltage 53230A statistics – 1M reading memory and RF signal strength
    [Show full text]
  • Chapter 26 Oscillator Is Sufficient for Most of Our Needs and Most Amateur Equipment Relies on This Technique
    Test Procedures and Projects 26 his chapter, written by ARRL Technical Advisor Doug Millar, K6JEY, covers the test equipment and measurement techniques common to Amateur Radio. With the increasing complexity of T amateur equipment and the availability of sophisticated test equipment, measurement and test procedures have also become more complex. There was a time when a simple bakelite cased volt-ohm meter (VOM) could solve most problems. With the advent of modern circuits that use advanced digital techniques, precise readouts and higher frequencies, test requirements and equipment have changed. In addition to the test procedures in this chapter, other test procedures appear in Chapters 14 and 15. TEST AND MEASUREMENT BASICS The process of testing requires a knowledge of what must be measured and what accuracy is required. If battery voltage is measured and the meter reads 1.52 V, what does this number mean? Does the meter always read accurately or do its readings change over time? What influences a meter reading? What accuracy do we need for a meaningful test of the battery voltage? A Short History of Standards and Traceability Since early times, people who measured things have worked to establish a system of consistency between measurements and measurers. Such consistency ensures that a measurement taken by one person could be duplicated by others — that measurements are reproducible. This allows discussion where everyone can be assured that their measurements of the same quantity would have the same result. In most cases, and until recently, consistent measurements involved an artifact: a physical object. If a merchant or scientist wanted to know what his pound weighed, he sent it to a laboratory where it was compared to the official pound.
    [Show full text]
  • Agilent Digital Multimeters
    Agilent Digital Multimeters Designed to handle your toughest assignments in various applications Index Measurement Digits of speed (reading/s Basic 1-yr DCV Connectivity & Model Description resolution at 42 digits) accuracy Basic measurements software Page: Benchtop DMM, 42 (U3401A) N/A 0.0120% DCV, ACV, DCI, ACI, N/A 4 dual display 52 (U3402A) 2-wire resistance (4-wire Elegantly simple on U3402A), frequency, and affordable continuity, and diode DMMs with basic and good capabilities U3401A/U3402A 5.5-digit DMM 52 26 0.0250% DCV, ACV, DCI, ACI, USB 2.0, GPIB 5 with built-in 30 W 2- and 4-wire resistance, power supply frequency, continuity, Halves bench/ diode, and capacitance rackspace need 30-W with four output for two instruments ranges, OVP/OCP, auto scan/ramp and square U3606A/U3606B wave generator 5.5 digit bench 52 190 0.0150% DCV, ACV, DCI, ACI, USB 2.0, 6 digital multimeter 2- and 4-wire resistance, Serial Interface OLED dual display frequency, continuity, (RS-232), GPIB diode, capacitance, and DMM Connectivity temperature Utility software (page 24) 34450A Bench/System 62 300/1000 0.0075/0.0035% DCV, ACV, DCI, ACI, USB, LAN/LXI 7 DMM 2- and 4-wire resistance, Core, GPIB, 34401A frequency, period, DMM Connectivity Replacement for continuity, diode, Utility (page 24) accuracy, speed, temperature measurement ease 34460A/34461A and versatility Bench/System 62 1000 0.0035% DCV, ACV, DCI, ACI, GPIB, RS-232, 8 DMM 2- and 4-wire resistance, DMM Connectivity Industry standard frequency, period, Utility software for accuracy, speed, continuity,
    [Show full text]
  • Oscilloscope Selection Guide Oscilloscope Selection Guide
    OSCILLOSCOPE SELECTION GUIDE OSCILLOSCOPE SELECTION GUIDE OSCILLOSCOPE SELECTOR GUIDE Tektronix offers oscilloscopes for many different applications and uses. To help you choose the right scope for your needs, the most common criteria for selecting a scope are listed below, along with helpful tips for determining your requirements. 1 Bandwidth All oscilloscopes have a low-pass frequency response that rolls CONTENTS off at higher frequencies. Oscilloscope bandwidth is specified as CHOOSING YOUR OSCILLOSCOPE 1-3 being the frequency at which a sinusoidal input signal is MIXED SIGNAL AND MIXED DOMAIN OSCILLOSCOPES 4-5 attenuated to 70.7% of the signal’s true amplitude – the -3 dB point. Your oscilloscope must have sufficient bandwidth to MSO/DPO2000B 4 capture all relevant frequency components of your signal. If you MDO3000 4 regularly work with digital signals, it may be easier to consider MDO4000C 5 bandwidth by comparing signal and oscilloscope rise time specifications. Use an oscilloscope with a rise time ADVANCED SIGNAL ANALYSIS OSCILLOSCOPES 6-7 specification five times faster than your signal rise time to MSO/DPO5000B 6 keep error below 2%. 5 Series MSO 6 Rule: Bandwidth > 5 x Highest Signal Frequency DPO7000C Series 7 MSO/DPO70000 Series 7 2 Sample Rate DPO70000SX Series 8 The faster an oscilloscope samples, the greater the resolution SAMPLING OSCILLOSCOPES 8 and detail of the displayed waveform, and the less likely that DSA8300 8 critical information or events will be lost. Tektronix recommends at least 5X oversampling to ensure signal details are captured BASIC OSCILLOSCOPES 9 and to avoid aliasing. TBS1000 9 Rule: Sample Rate > 5 x (Highest Frequency Component) TBS1000B/TBS1000B-EDU 9 TBS2000 9 BATTERY POWERED OSCILLOSCOPES 3 Record Length WITH ISOLATED CHANNELS 10 Record length is the number of samples the oscilloscope can THS3000 10 digitize and store in a single acquisition.
    [Show full text]
  • Build an Rf Frequency Counter Buffer for Hf
    BUILD IT YOURSELF By Dwayne Kincaid WD8OYG BUILD AN RF FREQUENCY COUNTER BUFFER FOR HF Most frequency counters can tolerate only low levels of RF at their input, but here’s a way to safely measure the frequency of an RF signal of up to 200 watts with your existing frequency counter. 36 January/February 2019 ■ FIGURE 1. Block diagram of frequency counter buffer. ■ FIGURE 2. Schematic of frequency counter buffer. his buffer allows you to connect your transceivers. It performs well, is easy to reproduce, counter to any RF source from 20 mW to is low cost, and has a minimal parts count. 200 watts, from 200 kHz to 60 MHz. The Most amateur HF transceivers are in the 5 to circuit has a protection limiter that keeps 200 watt range. This buffer (Figure 2) will allow Tthe RF signal strength in a safe range for the TTL you to connect your standard desktop frequency input of the counter, as well as providing gain for counter directly to the RF line, even with higher weaker signals (Figure 1). signal levels that most frequency counters can You can think of the buffer as a dam safely handle. For Citizens Band, most transceivers are in keeping high water out of Frequency Counter- the 4 to 12 watt range and will work fine with the ville. If the water/signal is too high upstream, buffer. you can limit how much of it gets through. Or, The low end of the buffer’s power range if its strength is too low, you can add some.
    [Show full text]
  • AN200-1 Fundamentals of Microwave Frequency Counters
    H Fundamentals of Microwave Frequency Counters Application Note 200-1 Electronic Counters Series 1 Table of Contents Down-Conversion Techniques for Automatic Microwave Frequency Counters ................................................. 3 Prescaling .................................................................................................... 3 Heterodyne Converter ............................................................................... 4 Transfer Oscillator ..................................................................................... 5 Harmonic Heterodyne Converter ............................................................ 6 Comparing the Principal Microwave Down-Conversion Techniques .................................................................................... 8 Measurement Speed .................................................................................. 8 Accuracy...................................................................................................... 8 Sensitivity and Dynamic Range ............................................................... 10 Signal-to-Noise Ratio ................................................................................. 11 FM Tolerance.............................................................................................. 12 AM Tolerance ............................................................................................. 14 Amplitude Discrimination ........................................................................ 14 Summary of the
    [Show full text]
  • Spectrum Analyzer
    Spectrum Analyzer GSP-9330 USER MANUAL ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will company. The information in this manual was correct at the time of printing. However, Good Will continues to improve products and reserves the rights to change specification, equipment, and maintenance procedures at any time without notice. Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan. Table of Contents Table of Contents SAFETY INSTRUCTIONS .................................................. 3 GETTING STARTED .......................................................... 8 GSP-9330 Introduction .......................... 9 Accessories .......................................... 12 Appearance .......................................... 14 First Use Instructions .......................... 26 BASIC OPERATION ........................................................ 38 Frequency Settings ............................... 41 Span Settings ....................................... 45 Amplitude Settings .............................. 48 Autoset ................................................ 62 Bandwidth/Average Settings ................ 64 Sweep .................................................. 70 Trace .................................................... 77 Trigger ................................................
    [Show full text]
  • Frequency Measurements and Mixer
    Frequency Measurements and Mixer Introduction In this laboratory experience the student will measure the frequency of some signal using a frequency counter and a frequency translating device (mixer). Available instrumentation For this practical session you will use the following instrumentation: waveform generator (Hameg 8130, Hameg 8131 or similar) LED signal generator (output C and D, 5 MHz) analog oscilloscope frequency counter (Hameg HM 8122 or similar) For manuals and documentation: http://led.polito.it/main it/instrumentation.asp or see the “Addendum” at the end of these pages Mixer The internal scheme and the pins of the mixer are shown in figures 1 and 2. Figure 1: simplified scheme of the SBL-3 mixer Figure 2: pin scheme for the SBL-3 mixer (as seen from the top) Frequency measurements You can measure the frequency of the signals indicated in table I with the frequency counter. Following the manual instructions you must evaluate the uncertainty. For the trigger related uncertainty you can use a S/N value of 80dB. What’s happen to the trigger uncertainty if the S/N is reduced to a value of 40dB? Table I: frequency measurements Signal f /Hz f /Hz 1 kHz from waveform generator 15 kHz from waveform generator 5 MHz from waveform generator 5 MHz from LED sign.gen. output C 5 MHz from LED sign.gen. output D Frequency difference measurement Compute the frequency difference between output C and output D, starting from the measurements you reported on the table I. Now you can evaluate the uncertainty of the frequency difference.
    [Show full text]
  • Electronic Measurement & Measuring Instruments Syllabus
    ELECTRONIC MEASUREMENT & MEASURING INSTRUMENTS SYLLABUS Module-I (12 Hours) Basics of Measurements: Accuracy, Precision, resolution, reliability, repeatability, validity, Errors and their analysis, Standards of measurement. Bridge Measurement: DC bridges- wheatstone bridge, AC bridges – Kelvin, Hay, Maxwell, Schering and Wien bridges, Wagner ground Connection. Electronic Instruments for Measuring Basic Parameters: Amplified DC meter, AC Voltmeter, True- RMS responding Voltmeter, Electronic multi-meter, Digital voltmeter, Vector Voltmeter. Module-II (12 Hours) Oscilloscopes: Cathode Ray Tube, Vertical and Horizontal Deflection Systems, Delay lines, Probes and Transducers, Specification of an Oscilloscope. Oscilloscope measurement Techniques, Special Oscilloscopes – Storage Oscilloscope, Sampling Oscilloscope. Signal Generators: Sine wave generator, Frequency – Synthesized Signal Generator, Sweep frequency Generator. Pulse and square wave generators. Function Generators. Module-III (10 Hours) Signal Analysis: Wave Analyzer, Spectrum Analyzer. Frequency Counters: Simple Frequency Counter; Measurement errors; extending frequency range of counters Transducers: Types, Strain Gages, Displacement Transducers. Module-IV (6 Hours) Digital Data Acquisition System: Interfacing transducers to Electronics Control and Measuring System. Instrumentation Amplifier, Isolation Amplifier. An Introduction to Computer-Controlled Test Systems.IEEE-488 GPIB Bus Text Books: 1. Modern Electronics Instrumentation & Measurement Techniques, by Albert D.Helstrick and William D.Cooper, Pearson Education. Selected portion from Ch.1, 5-13. 2. Elements of Electronics Instrumentation and Measurement-3rd Edition by Joshph J.Carr.Pearson Education. Selected portion from Ch.1,2,4,7,8,9,13,14,18,23 and 25. Reference Books : 3. Electronics Instruments and Instrumentation Technology – Anand, PHI 4. Doebelin, E.O., Measurement systems, McGraw Hill, Fourth edition, Singapore, 1990. MODULE –I Chapter 1. Basics of Measurements 1.
    [Show full text]