Digital Multimeter Function Generator, Model 1247-10

Total Page:16

File Type:pdf, Size:1020Kb

Digital Multimeter Function Generator, Model 1247-10 Digital Multimeter / Function Generator 580853 (1247-15) LabVolt Series Datasheet Festo Didactic en 220 V - 60 Hz * The product images shown in this document are for illustration purposes; actual products may vary. Please refer to the Specifications section of each product/item for all details. Festo Didactic reserves the right to change product images and specifications at any time without notice. 10/2021 Digital Multimeter / Function Generator, LabVolt Series Table of Contents General Description _________________________________________________________________________________ 2 Features & Benefits _________________________________________________________________________________ 2 Manual ___________________________________________________________________________________________ 2 Specifications______________________________________________________________________________________ 2 General Description The Digital Multimeter / Function Generator is a compact, general-purpose instrumentation module that provides the necessary test equipment (except the oscilloscope) to perform the courses in the FACET program. The module consists of a sine/square/triangle waveshape function generator and an auto-ranging digital multimeter. All instruments share a common power input and are housed in a portable enclosure. All components, switches, and terminals are mounted in a tamper-resistant manner. The module’s design protects the instruments from inadvertent short circuits and overloads in the context of the FACET training system. The 3½ digit multimeter uses a liquid-crystal display (LCD) with auto-ranging capability for the voltage, ohms, and frequency functions. In addition, two current ranges (200 mA and 2 A) can be selected manually. Internal circuit protection is provided on all functions and ranges, except the current input, which is fuse protected. The sine/square/triangle waveshape generator provides a continuously adjustable output signal from 0 to 20 V peak-to-peak into an open circuit. The frequency coverage is continuous over 20 Hz to 200 kHz in four ranges and can be monitored internally using the frequency counter of the multimeter. The output is protected against overload conditions by the clamping action of diodes built into the internal circuitry. The Digital Multimeter / Function Generator is provided with all the necessary leads, as well as a user's manual for an easy introduction into its operation. Features & Benefits • Easy-to-read, silk-screened front panel • 3½ digit auto-ranging multimeter • Function generator • A tilt bail is included and can be attached using a screwdriver Manual Manual Description number Digital Multimeter / Function Generator (User Guide) _____________________________________583878 (20799-E0) Specifications Parameter Value Digital Multimeter Ranges DC Voltage 200 mV, 2 V, 20 V, 200 V, 250 V DC Current 200 mA, 2 A AC Voltage 200 mV, 2 V, 20 V, 200 V, 250 V AC Current 200 mA, 2 A Resistance 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ Frequency 2000 Hz, 20 kHz, 200 kHz, 2 MHz, 20 MHz Measurement Accuracy DC Voltage 0.5% of input ±2 counts © Festo Didactic 2 Digital Multimeter / Function Generator, LabVolt Series Parameter Value DC Current 1.5% of input ±2 counts AC Voltage 1.5% of input ±2 counts AC Current 1.5% of input ±2 counts Resistance (200 Ω, 2 kΩ, 20 kΩ, 200 kΩ) 0.5% of input ±2 counts Resistance (2 MΩ) 1% of input ±2 counts Resistance (20 MΩ) 3% of input ±2 counts Frequency 0.1% of input ±1 count Display Readout 3½ digits, 7 segments, LCD Conversion Range 2 samples/s Overrange Indication OL (Overload) Input Impedance (Voltages) 9 MΩ or greater on all voltage ranges (greater than 80 MΩ on 200 mV range) Voltage Drop Across Current Input 1 V max. Resolution (Lowest Range) Voltage 0.1 mV Current 10 μA Resistance 0.1 Ω Frequency 1 Hz Power Requirements Current 0.055 A Service Installation Standard single-phase ac outlet Resistance Measurement (Open-Circuit Voltage) 20 MΩ Range < 1.25 V Up to 2 MΩ Range < 500 mV Diode Measurement 2.0 V max. Overload Protection Voltage 250 V Current 2.5 A Fuse Resistance + Frequency 250 V Protection Internal circuit protection provided on all functions and ranges. Function Generator Frequency Range 20 Hz to 200 kHz Output Amplitude (Open Circuit) 20 V p-p Output Impedance 50 Ω ±20% Sine Wave Distortion Less than 1% Square Wave Rise Time (Typical) 40 ns Triangle Wave Linearity 3% The output is protected against overload conditions by the clamping action of diodes built into the internal Protection circuitry. Physical Characteristics Intended Location On a table able to support the weight of the equipment Dimensions (H x W x D) 155 x 219 x 140 mm (6.1 x 8.6 x 5.5 in) Net Weight 2.9 kg (6.4 lb) 3 © Festo Didactic Digital Multimeter / Function Generator, LabVolt Series Reflecting the commitment of Festo Didactic to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification. Festo Didactic reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors. Festo Didactic recognizes all product names used herein as trademarks or registered trademarks of their respective holders. © Festo Didactic Inc. 2021. All rights reserved. Festo Didactic SE Rechbergstrasse 3 73770 Denkendorf Germany P. +49(0)711/3467-0 F. +49(0)711/347-54-88500 Festo Didactic Inc. 607 Industrial Way West Eatontown, NJ 07724 United States P. +1-732-938-2000 F. +1-732-774-8573 Festo Didactic Ltée/Ltd 675 rue du Carbone Québec QC G2N 2K7 Canada P. +1-418-849-1000 F. +1-418-849-1666 www.labvolt.com www.festo-didactic.com © Festo Didactic 4.
Recommended publications
  • MXG X-Series Signal Generators N5183B Microwave Analog 9 Khz to 13, 20, 31.8, Or 40 Ghz
    MXG X-Series Signal Generators N5183B Microwave Analog 9 kHz to 13, 20, 31.8, or 40 GHz Find us at www.keysight.com Page 1 Definitions Specification (spec): Specifications represent warranted performance of a calibrated instrument that has been stored for a minimum of 2 hours within the operating temperature range of 0 to 55 °C, unless otherwise stated, and after a 45 minutes warm-up period. The specifications include measurement uncertainty. Data represented in this document are specifications unless otherwise noted. Typical (typ): Typical (typ) describes additional product performance information. It is performance beyond specifications that 80 percent of the units exhibit with a 95 percent confidence level at room temperature (approximately 25 °C). Typical performance does not include measurement uncertainty. Nominal (nom) or measured (meas): Nominal (nom) or measured (meas) describes a performance attribute that is by design or measured during the design phase for the purpose of communicating sampled, mean, or average performance, such as the 50-ohm connector or amplitude drift vs. time. This data is not warranted and is measured at room temperature (approximately 25 °C). Find us at www.keysight.com Page 2 Frequency Specifications Range Frequency range Option 513 9 kHz to 13 GHz Option 520 9 kHz to 20 GHz Option 532 9 kHz to 31.8 GHz Option 540 9 kHz to 40 GHz Resolution 0.001 Hz Phase offset Adjustable in nominal 0.1° increments Frequency switching speed 1 () = typical Standard Option UNZ 2, 4 Option UZ2 3, 4 CW mode SCPI mode (≤ 5 ms) ≤ 1.15 ms (≤ 750 μs) < 1.65 ms (1 ms) List/step sweep mode (≤ 5 ms) ≤ 900 μs (≤ 600 μs) < 1.4 ms (850 μs) 1.
    [Show full text]
  • The Oscilloscope and the Function Generator: Some Introductory Exercises for Students in the Advanced Labs
    The Oscilloscope and the Function Generator: Some introductory exercises for students in the advanced labs Introduction So many of the experiments in the advanced labs make use of oscilloscopes and function generators that it is useful to learn their general operation. Function generators are signal sources which provide a specifiable voltage applied over a specifiable time, such as a \sine wave" or \triangle wave" signal. These signals are used to control other apparatus to, for example, vary a magnetic field (superconductivity and NMR experiments) send a radioactive source back and forth (M¨ossbauer effect experiment), or act as a timing signal, i.e., \clock" (phase-sensitive detection experiment). Oscilloscopes are a type of signal analyzer|they show the experimenter a picture of the signal, usually in the form of a voltage versus time graph. The user can then study this picture to learn the amplitude, frequency, and overall shape of the signal which may depend on the physics being explored in the experiment. Both function generators and oscilloscopes are highly sophisticated and technologically mature devices. The oldest forms of them date back to the beginnings of electronic engineering, and their modern descendants are often digitally based, multifunction devices costing thousands of dollars. This collection of exercises is intended to get you started on some of the basics of operating 'scopes and generators, but it takes a good deal of experience to learn how to operate them well and take full advantage of their capabilities. Function generator basics Function generators, whether the old analog type or the newer digital type, have a few common features: A way to select a waveform type: sine, square, and triangle are most common, but some will • give ramps, pulses, \noise", or allow you to program a particular arbitrary shape.
    [Show full text]
  • Design About Simple Tester of Low Capacitance Based on MAX038
    Information Technology and Mechatronics Engineering Conference (ITOEC 2015) Design about Simple Tester of Low Capacitance Based on MAX038 Zheng Liping1,a 1Photoelectric Engineering College of Yunnan Open University, Kunming, China, 650500 [email protected] Keywords: MAX038, test of low capacitance, TM4C123GH6PM, frequency measurement by equal precision Abstract. Simple tester of low capacitance was designed based on MAX038 in this paper. The principle is that external capacitor of MAX038 as test capacitor to provide corresponding frequency signal output, and TM4C123GH6PM was selected to measure frequency by equal precision and calculate test capacitance. In order to improve the accuracy, data were piecewise fitted by the least square method, and comparison tests were between high accuracy capacitance tester and the simple tester to realize auto correction and show measurement results. The tester can detect 10pF~1µF capacitor. Test results show that the tester is running stable, rapid measuring; accuracy is grade 1. Introduction In this paper, through the research of how standard function signals are generated and the relationship between signal frequency and capacitance values, we designed this portable capacitor tester based on MAX038. In the design, we applied digital signal processing technique [1,4] and the method of ratio correcting [5], making the tester faster and more accurate. It can be functioned not only as a general portable capacitance tester, but also as suitable subject for students, so that they can grow through practice, and be excellent after repeated renovation. The Hardware Components and Working Principle of Simple Tester of Low Capacitance The capacitance test system designed in this paper include power module, function signal generator module, zoom conditioning module, TM4C123GH6PM control system and display module, the systematic structure can be shown in Figure 1.
    [Show full text]
  • Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science
    Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science 6.002 - Circuits and Electronics Fall 2004 Lab Equipment Handout (Handout F04-009) Prepared by Iahn Cajigas González (EECS '02) Updated by Ben Walker (EECS ’03) in September, 2003 This handout is intended to provide a brief technical overview of the lab instruments which we will be using in 6.002: the oscilloscope, multimeter, function generator, and the protoboard. It incorporates much of the material found in the individual instrument manuals, while including some background information as to how each of the instruments work. The goal of this handout is to serve as a reference of common lab procedures and terminology, while trying to build technical intuition about each instrument's functionality and familiarizing students with their use. Students with previous lab experience might find it helpful to simply skim over the handout and focus only on unfamiliar sections and terminology. THE OSCILLOSCOPE The oscilloscope is an electronic instrument based on the cathode ray tube (CRT) – not unlike the picture tube of a television set – which is capable of generating a graph of an input signal versus a second variable. In most applications the vertical (Y) axis represents voltage and the horizontal (X) axis represents time (although other configurations are possible). Essentially, the oscilloscope consists of four main parts: an electron gun, a time-base generator (that serves as a clock), two sets of deflection plates used to steer the electron beam, and a phosphorescent screen which lights up when struck by electrons. The electron gun, deflection plates, and the phosphorescent screen are all enclosed by a glass envelope which has been sealed and evacuated.
    [Show full text]
  • Function Generator and Oscilloscope
    Summer 2007 Lab 2 EE100/EE43 EECS 100/43 Lab 2 – Function Generator and Oscilloscope 1. Objective In this lab you learn how to use the oscilloscope and function generator 2. Equipment a. Breadboard b. Wire cutters c. Wires d. Oscilloscope e. Function Generator f. 1k resistor x 2 h. Various connectors (banana plugs-to-alligator clips) for connecting breadboard to power supply and for multimeter connections. 3. Theory a. The HP33120A Function Generator The front panel of your function generator is shown in Figure 1. This instrument outputs a time-varying periodic voltage signal (the OUTPUT connector, do not use the sync connector, refer to figure 2). By pushing the appropriate buttons on the front panel, the user can specify various characteristics of the signal. Figure 1. Front panel of your function generator (Ref: Agilent Function Generator User’s Guide #33120-90006) University of California, Berkeley Department of EECS Summer 2007 Lab 2 EE100/EE43 Figure 2. Make sure you use BLACK BNC input cables. Connect them to the OUTPUT terminal as shown above. Do not use the SYNC connector The main characteristics that you will be concerned with in this class are: • Shape: sine, square, or triangle waves. • Frequency: inverse of the period of the signal; units are cycles per second (Hz) • Vpp: peak to peak Voltage value of the signal • DC Offset: constant voltage added to the signal to increase or decrease its mean or average level. In a schematic, this would be a DC voltage source in series with the oscillating voltage source. Figure 3 below illustrates a couple of the parameters above.
    [Show full text]
  • EE 462G Laboratory #1 Measuring Capacitance
    EE 462G Laboratory #1 Measuring Capacitance Drs. A.V. Radun and K.D. Donohue (1/24/07) Revised by Samaneh Esfandiarpour and Dr. David Chen (9/17/2019) Department of Electrical and Computer Engineering University of Kentucky Lexington, KY 40506 I. Instructional Objectives Introduce lab instrumentation with linear circuit elements Introduce lab report format Develop and analyze measurement procedures based on two theoretical models Introduce automated lab measurement and data analysis II. Background A circuit design requires a capacitor. The value of an available capacitor cannot be determined from its markings, so the value must be measured; however a capacitance meter is not available. The only available resources are different valued resistors, a variable frequency signal generator, a digital multi-meter (DMM), and an oscilloscope. Two possible ways of measuring the capacitor’s value are described in the following paragraphs. For this experiment, the student needs to select resistors and frequencies that are convenient and feasible for the required measurements and instrumentation. Be sure to use the digital multi-meter (DMM) to measure and record the actual resistance values used in each measurement procedure. III. Pre-Laboratory Exercise Step Response Model 1. For a series circuit consisting of a voltage source v(t), resistor R, and capacitor C, derive (show all steps) the complete solution for the capacitor voltage vc(t) when the source is a step with amplitude A and the initial capacitor voltage is 0. 2. Assume the source v(t) is a function generator, where the source voltage can only be measured after the 50 Ω internal resistance.
    [Show full text]
  • Tektronix Signal Generator
    Signal Generator Fundamentals Signal Generator Fundamentals Table of Contents The Complete Measurement System · · · · · · · · · · · · · · · 5 Complex Waves · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 15 The Signal Generator · · · · · · · · · · · · · · · · · · · · · · · · · · · · 6 Signal Modulation · · · · · · · · · · · · · · · · · · · · · · · · · · · 15 Analog or Digital? · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 7 Analog Modulation · · · · · · · · · · · · · · · · · · · · · · · · · 15 Basic Signal Generator Applications· · · · · · · · · · · · · · · · 8 Digital Modulation · · · · · · · · · · · · · · · · · · · · · · · · · · 15 Verification · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 8 Frequency Sweep · · · · · · · · · · · · · · · · · · · · · · · · · · · 16 Testing Digital Modulator Transmitters and Receivers · · 8 Quadrature Modulation · · · · · · · · · · · · · · · · · · · · · 16 Characterization · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 8 Digital Patterns and Formats · · · · · · · · · · · · · · · · · · · 16 Testing D/A and A/D Converters · · · · · · · · · · · · · · · · · 8 Bit Streams · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 17 Stress/Margin Testing · · · · · · · · · · · · · · · · · · · · · · · · · · · 9 Types of Signal Generators · · · · · · · · · · · · · · · · · · · · · · 17 Stressing Communication Receivers · · · · · · · · · · · · · · 9 Analog and Mixed Signal Generators · · · · · · · · · · · · · · 18 Signal Generation Techniques
    [Show full text]
  • © Rohde & Schwarz Solutions for the Educational Market
    ROHDE & SCHWARZ SOLUTIONS FOR THE EDUCATIONAL MARKET UP TO 30% OFF for EDU Customers 1 2 Rohde & Schwarz Solutions for the educational market ROHDE & SCHWARZ IN THE EDUCATIONAL MARKET Test and measurement specialist Rohde & Schwarz has decades of experience in producing innovative, class-leading test and measurement solutions that guarantee high quality, compatibility and precision. With its solid technological background, Rohde & Schwarz is proud to support universities and carry the legacy of cooperation forward. Rohde & Schwarz was founded by two PhD students, The search for synergy goes beyond providing universities Lothar Rohde and Hermann Schwarz, who were working with test and measurement equipment. Rohde & Schwarz together at the University of Jena in Germany. Over 80 considers universities and schools as partners. The company years ago, they decided to bring their mutual interest organizes guest lectures by leading experts as well as in high frequency technology into practice by opening seminars and training courses for both specialists and the Physikalisch-Technisches Entwicklungslabor students, and is involved in sponsoring engineering student Dr. L. Rohde & Dr. H. Schwarz in Munich. competitions and hackathons with test equipment. Ever since the company was started, Rohde & Schwarz Maintaining close ties with the educational field is has stayed true to the innovative enthusiasm of its young mutually beneficial. In addition to providing useful tools founders by creating and maintaining close connections for teaching, Rohde & Schwarz is keeping up-to-date with with educational institutions. Rohde & Schwarz is committed the specific needs and peculiarities of the educational to cultivating this highly valued cooperation by providing market. With one of them being budgetary restrictions, universities and schools with reliable and novel test and the company proactively offers special terms and measurement solutions of high quality, ideally suited discounts for the customers in the educational market.
    [Show full text]
  • 03208523-MIT.Pdf
    2 DESIGN OF A P OGRAi&ABLE OPTICAL SCANNER by ANDREW C. FRECHTLING Submitted to the Department of Mechanical Engineering on June 28,1976,in partial fulfillment of the requirements for the Degree of Bachelor of Science in Mech- anical Engineering. ABSTRACT To photograph three-dimensional fluid flow,a laser scanning device capable of scanning through 60 ppints per second is required. A General Scanning Ge-300PD galvanometer-type scanneroperateut under closed-loop control,can achieve the necessary speed of response. The desired scan points are to be pre-programmed as a series of DC voltage inputs,using a step function generator built up of analog and digital elements. The closed-loop controller to be used is the A-603 amplifier, also designed by General Scanning. The complete scanner system will consist of the step function generator,used as a reference signal,and the control circuitwhich will drive the scanner. Thesis Supervisor: C. Forbes Dewey, Jr. Title: Professor of Mechanical Engineering :3 ACKNOv'LEDGEMENTS I would like to extend special thanks to Prof. C. Forbes Dewey, who provided the initial idea for this thesis and who has been immensely helpful ever since. Acknowledgements are also due Dick Fenner and Lon Hocker, who have given me invaluable aia and advice around and about the Fluids Lab. I would like to thank Ken Yeager,of the Joint Computer Facility,for his guidance through the field of digital electronics. Prof. Bell, Prof. Wormley, and Prof. Sidell have all been very helpful in discussing problems of control design with me. To all of the above,I am very grateful i this thesis truly couldn't have been done without their help.
    [Show full text]
  • A Guide to Calibrating Your Spectrum Analyzer
    A Guide to Calibrating Your Spectrum Analyzer Application Note Introduction As a technician or engineer who works with example, the test for noise sidebands that deter- electronics, you rely on your spectrum analyzer to mines whether the spectrum analyzer meets its verify that the devices you design, manufacture, phase noise specification often expresses the results and test—devices such as cell phones, TV broadcast in dBc, while analyzer specifications are typically systems, and test equipment—are generating the quoted in dBc/Hz. Consequently, the test engineer proper signals at the intended frequencies and must convert dBc to dBc/Hz as well as applying levels. For example, if you work with cellular radio several correction factors to determine whether the systems, you need to ensure that carrier signal spectrum analyzer is in compliance with specifications. harmonics won’t interfere with other systems For these reasons, spectrum analyzer calibra- operating at the same frequencies as the harmon- tion is a task best handled by skilled metrolo- ics; that intermodulation will not distort the infor- gists, who have both the necessary equipment mation modulated onto the carrier; that the device and an in-depth understanding of the procedures complies with regulatory requirements by operating involved. Still, it’s helpful for everyone who works at the assigned frequency and staying within the with spectrum analyzers to understand the value allocated channel bandwidth; and that unwanted of calibrating these instruments. This application emissions, whether radiated or conducted through note is intended both to help application engineers power lines or other wires, do not impair the opera- who work with spectrum analyzers understand the tion of other systems.
    [Show full text]
  • Lab 2: Oscilloscopes and Function Generators
    EE 206 Lab 2: Oscilloscopes and Function Generators Objectives: To learn the basic operations of an oscilloscope and of a function generator. Equipment Needed: Breadboard, CADET, function generator, multimeter, oscilloscope Parts List: 2.0 kW and 10.0 kW resistors from Lab kit Introduction An oscilloscope is used to measure and display signals. The oscilloscope can display the waveform of any dc or varying signal. It can also be used to measure the amplitude, frequency, and time period of any periodic signal. A function generator (also called a “signal generator”) is used to produce a time­varying signal with various characteristics. Part I: Measuring dc Voltage using the Oscilloscope 1. Review the oscilloscope manual in the lab to become familiar with the operation and controls of the oscilloscope. 2. Set the CH 1 VOLTS/DIV setting of the oscilloscope to 2 V. 3. Connect CH 1 to the 1.3 – 15 V dc supply of the CADET. Note: one lead of the oscilloscope probe is always ground. Always be sure that this ground corresponds to the ground of the CADET. 4. Measure this supply voltage using both the oscilloscope and the multimeter. Observe the effect of varying the dc voltage and varying the VOLTS/DIV setting on the oscilloscope. Record at least five different voltage observations that differ by at least 2.0 V. Compare the readings you obtain from the oscilloscope and from the multimeter. Part II: Operating a Function Generator 1. Review the function generator manual in the lab to become familiar with the operation and controls of the function generator.
    [Show full text]
  • Microwave Signal Generator 2500B Series - 100 Khz to 50 Ghz
    Technical Datasheet Microwave Signal Generator 2500B Series - 100 kHz to 50 GHz Ultra-Low Phase Noise and Fast-Switching Speed in a Single Unit 34797-Rev.L / US052015 Table of Contents Frequency Ranges and available options ......................................................................................................................................... 1 Frequency Reference and Frequency Bands .................................................................................................................................... 2 Output Power ................................................................................................................................................................................... 3 Power Level Accuracy ....................................................................................................................................................................... 5 Switching Speed ................................................................................................................................................................................ 7 Sweep Modes ................................................................................................................................................................................... 8 Remote programming ...................................................................................................................................................................... 8 Spectral Purity .................................................................................................................................................................................
    [Show full text]