Agilent 2100 Bioanalyzer 2100 Expert User's Guide

Total Page:16

File Type:pdf, Size:1020Kb

Load more

Agilent 2100 Bioanalyzer 2100 Expert User’s Guide s1 Notices implied, with regard to this manual and any information con- tained herein, including but not limited to the implied war- © Agilent Technologies, Inc. 2000-2006 ranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for inciden- No part of this manual may be reproduced in any form or by tal or consequential damages in connection with the fur- any means (including electronic storage and retrieval or nishing, use, or performance of this document or of any translation into a foreign language) without prior agreement information contained herein. Should Agilent and the user and written consent from Agilent Technologies, Inc. as have a separate written agreement with warranty terms governed by United States and international copyright laws. covering the material in this document that conflict with these terms, the warranty terms in the separate agreement Manual Part number: G2946-90004 shall control. Edition: June 2006 Restricted Rights Legend Agilent Technologies If software is for use in the performance of a U.S. Govern- Hewlett-Packard Str. 8 ment prime contract or subcontract, Software is delivered 76337 Waldbronn and licensed as “Commercial computer software” as Germany defined in DFAR 252.227-7014 (June 1995), or as a “com- mercial item” as defined in FAR 2.101(a) or as “Restricted computer software” as defined in FAR 52.227-19 (June Adobe and Acrobat are U.S. registered trademarks of Adobe 1987) or any equivalent agency regulation or contract Systems Incorporated. clause. Use, duplication or disclosure of Software is subject to Agilent Technologies’ standard commercial license Microsoft® and Windows® are U.S. registered trademarks terms, and non-DOD Departments and Agencies of the U.S. of Microsoft Corporation. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Gov- ernment users will receive no greater than Limited Rights as Technology Licenses defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Warranty The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by appli- cable law, Agilent disclaims all warranties, either express or Contents ▲ 2 ▼ Index Contents About this Manual ..................................................................................................................5 In this Manual............................................................................................................................. 6 Related Documents ................................................................................................................... 8 How to Use this Manual ......................................................................................................... 11 Quick Start.............................................................................................................................15 Looking at 2100 Expert .........................................................................................................29 Introduction to the Key Features of the 2100 expert.......................................................... 30 Starting 2100 Expert ................................................................................................................ 32 2100 Expert Work Area ........................................................................................................... 33 Closing 2100 Expert ................................................................................................................. 44 Running and Evaluating Electrophoretic Assays ..............................................................46 Principles of Nucleic Acid and Protein Analysis on a Chip............................................... 47 Preparing and Running an Electrophoretic Assay.............................................................. 51 Analyzing and Evaluating the Results of an Electrophoretic Assay................................ 82 Result Flagging....................................................................................................................... 157 Running and Evaluating Flow Cytometric Assays...........................................................171 Principles of Flow Cytometric Measurements.................................................................. 172 Overview of Flow Cytometric Assays ................................................................................. 181 Contents ▲ 3 ▼ Index Preparing and Running a Flow Cytometric Assay ............................................................ 184 Analyzing and Evaluating the Results of a Flow Cytometric Assay............................... 217 Working with Chip Data and Assays................................................................................264 2100 Expert Data Overview .................................................................................................. 265 Handling Assays..................................................................................................................... 268 Handling Chip Data................................................................................................................ 273 Organizing, Backing up, and Archiving 2100 Expert Data ............................................... 275 Importing Data........................................................................................................................ 277 Exporting Data ........................................................................................................................ 283 Printing Reports ..................................................................................................................... 292 Configuring Tables................................................................................................................. 299 Administering System Functions ......................................................................................305 Configuring 2100 expert........................................................................................................ 306 Using Log Books .................................................................................................................... 316 Running Instrument Diagnostics ......................................................................................322 How to Run Instrument Diagnostics Tests........................................................................ 327 Performing Verifications....................................................................................................331 Products, Spare Parts, and Accessories..........................................................................340 Glossary ...............................................................................................................................344 Contents ▲ 4 ▼ Index About this Manual Welcome to the User’s Guide for the Agilent 2100 expert software. This manual provides beginners and advanced users with information needed to successfully run electrophoretic and flow cytometric assays with the bioanalyzer. The 2100 expert software allows the control of the bioanalyzer (including diagnostic functions) and, in combination with a LabChip kit, the acquisition, interpretation and result presentation of data generated during the analysis of DNA, RNA, proteins, and cells. Contents ▲ 5 ▼ Index In this Manual This manual provides bioanalyzer users with the following information: • “About this Manual” on page 5 gives an overview of the subjects in this manual, and lists major innovations and improvements of the 2100 expert software. It also lists supplemental literature and shows you how to make efficient use of this manual. • “Quick Start” on page 15 is meant for experienced users. It briefly summarizes the necessary steps to prepare and run an assay. • “Looking at 2100 Expert” on page 29 shows how to get started with the 2100 expert software, and outlines its main operational possibilities. • “Running and Evaluating Electrophoretic Assays” on page 46 explains how electrophoretic measurements are made using the bioanalyzer, gives detailed descriptions of all steps necessary to run electrophoretic assays, and shows how to analyze and evaluate results using electropherograms and gel-like images. • “Running and Evaluating Flow Cytometric Assays” on page 171 explains how flow cytometric measurements are made using the bioanalyzer, gives detailed descriptions of all steps necessary to run flow cytometric assays, and shows how to analyze and evaluate results using histograms and dot plots. • “Working with Chip Data and Assays” on page 264 shows you what to do to open, save, import and export files, and how to print the results. • “Administering System Functions” on page 305 is your guideline for configuring the 2100 expert software. • “Running Instrument Diagnostics” on page 322 shows how to use the diagnostic tests to check the bioanalyzer hardware for proper functioning. Contents ▲ 6 ▼ Index • “Performing Verifications” on page 331 describes how you can validate your bioanalyzer system. • “Products, Spare Parts, and Accessories”
Recommended publications
  • Validation of Two Ribosomal RNA Removal Methods for Microbial Metatranscriptomics

    Validation of Two Ribosomal RNA Removal Methods for Microbial Metatranscriptomics

    ANaLYSIS Validation of two ribosomal RNA removal methods for microbial metatranscriptomics Shaomei He1,2,5, Omri Wurtzel3,5, Kanwar Singh1, Jeff L Froula1, Suzan Yilmaz1, Susannah G Tringe1, Zhong Wang1, Feng Chen1, Erika A Lindquist1, Rotem Sorek3 & Philip Hugenholtz1,2,4 The predominance of rRNAs in the transcriptome is a major Among these methods, subtractive hybridization and exo- technical challenge in sequence-based analysis of cDNAs from nuclease digestion have become the most popular owing to the microbial isolates and communities. Several approaches have availability of commercial kits from Ambion (MICROBExpress been applied to deplete rRNAs from (meta)transcriptomes, but Bacterial mRNA Enrichment kit) and Epicentre (mRNA-ONLY no systematic investigation of potential biases introduced by Prokaryotic mRNA Isolation kit). The former kit uses a subtrac- any of these approaches has been reported. Here we validated tive hybridization with capture oligonucleotides specific to 16S the effectiveness and fidelity of the two most commonly and 23S rRNAs. It has been applied to both bacterial isolates used approaches, subtractive hybridization and exonuclease and environmental samples, in one or two rounds6,13–18. The digestion, as well as combinations of these treatments, on Epicentre kit uses exonuclease to preferentially degrade processed two synthetic five-microorganism metatranscriptomes using RNAs with 5′ monophosphate (the majority of which are believed massively parallel sequencing. We found that the effectiveness to be rRNAs)19,20. In some instances, these methods have been of rRNA removal was a function of community composition and used in combination to improve rRNA removal21–23. There is no RNA integrity for these treatments.
  • Comparison of RIN and Rine Algorithms for the Agilent 2100 Bioanalyzer and the Agilent 2200 Tapestation Systems Technical Overview

    Comparison of RIN and Rine Algorithms for the Agilent 2100 Bioanalyzer and the Agilent 2200 Tapestation Systems Technical Overview

    Comparison of RIN and RINe algorithms for the Agilent 2100 Bioanalyzer and the Agilent 2200 TapeStation systems Technical Overview Introduction A typical application for the 96-well plate compatible Agilent 2200 TapeStation system is automated, effi cient, and reliable RNA analysis, including RNA charac- terization and quality assessment with Agilent R6K ScreenTape or Agilent High Sensitivity R6K ScreenTape. When separated by electrophoresis, eukaryotic total RNA samples typically display two major peaks representing the 18S and 28S ribosomal RNA (rRNA). Depending on the purifi cation method, additional smaller peaks can also been seen, which correspond to small rRNAs as well as tRNAs. As total RNA degrades, the 18S and 28S rRNA peaks slowly disappear and the degradation products emerge in the region between the 18S and small RNAs, termed as the fast zone. The RNA integrity number (RIN) functionality of the Agilent 2100 Expert software for the Agilent 2100 Bioanalyzer system uses a proprietary neural network trained algorithm to make an assessment of the entire electrophoretic trace for a given total RNA sample, including ribosomal peak ratios, separation, and the presence or absence of degradation products. RIN values from 1 to 10 can be obtained, where 10 indicates the highest possible RNA quality. Due to fundamental differences in the nature of the raw data, a dedicated soft- ware algorithm has been developed for the 2200 TapeStation system and R6K ScreenTape to determine the RNA integrity number equivalent (RINe). The RINe algorithm is based on a Experimental RNA preparation mathematical model that calculates an Total RNA from HEK 293, Hep G2, and objective quantitative measurement of Material Jurkat cells was purifi ed using the RNA degradation1.
  • ACE-2019-Query-Builder-And-Tree

    ACE-2019-Query-Builder-And-Tree

    Copyright © 2019 by Aras Corporation. This material may be distributed only subject to the terms and conditions set forth in the Open Publication License, V1.0 or later (the latest version is presently available at http://www.opencontent.org/openpub/). Distribution of substantively modified versions of this document is prohibited without the explicit permission of the copyright holder. Distribution of the work or derivative of the work in any standard (paper) book form for a commercial purpose is prohibited unless prior permission is obtained from the copyright holder. Aras Innovator, Aras, and the Aras Corp "A" logo are registered trademarks of Aras Corporation in the United States and other countries. All other trademarks referenced herein are the property of their respective owners. Microsoft, Office, SQL Server, IIS and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Notice of Liability The information contained in this document is distributed on an "As Is" basis, without warranty of any kind, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose or a warranty of non-infringement. Aras shall have no liability to any person or entity with respect to any loss or damage caused or alleged to be caused directly or indirectly by the information contained in this document or by the software or hardware products described herein. Copyright © 2019 by Aras Corporation. This material may be distributed only subject to the terms and conditions set forth in the Open Publication License, V1.0 or later (the latest version is presently available at http://www.opencontent.org/openpub/).
  • Kurzweil 1000 Version 12 New Features

    Kurzweil 1000 Version 12 New Features

    Kurzweil 1000 Version 12 New Features For the most up-to-date feature information, refer to the Readme file on the product CD. The following is a summary of what’s new in Version 12. For complete details, go to the online Manual by pressing Alt+H+O. Where applicable, Search key words are provided for you to use in the online Manual. • While you may not notice any difference, the internal structure of Kurzweil 1000 Version 12 has been overhauled and now uses Microsoft .NET Framework. The intent is to make it easier for Cambium Learning Technologies to develop features for the product going forward. • Note that Kurzweil 1000 Version 12 now supports 64-bit operating systems and Microsoft Windows 7 operating system. • As always, Kurzweil 1000 has the latest OCR engines, FineReader 9.0.1 and ScanSoft 16.2. The new ScanSoft version includes recognition languages from the Sami family. • An especially exciting new feature is the New User Wizard, a set of topics that introduces and walks new users through a number of Kurzweil 1000 features and preference setups. It appears when you start up Kurzweil 1000, but can be disabled and accessed from the Help menu by pressing Alt+H+W. (Search: New User Wizard.) • Currency Recognition has been updated to support new bills. Note that Currency Recognition now requires a color scanner. • New features and enhancements in reference tools include: 1. updates of the American Heritage Dictionary and Roget’s Thesaurus. 2. the ability to find up to 114 of your previously looked up entries; and last but not least the addition to dictionary and thesaurus lookup of human pronunciations and Anagrams.
  • A Mobile Interface for Navigating Hierarchical Information Space$

    A Mobile Interface for Navigating Hierarchical Information Space$

    Journal of Visual Languages and Computing 31 (2015) 48–69 Contents lists available at ScienceDirect Journal of Visual Languages and Computing journal homepage: www.elsevier.com/locate/jvlc A mobile interface for navigating hierarchical information space$ Abhishek P. Chhetri a,n, Kang Zhang b,c, Eakta Jain c,d a Computer Engineering Program, Erik Jonsson School of Engineering and Computer Science, University of Texas at Dallas, Richardson, TX 65080-3021, USA b School of Software Engineering, Tianjin University, Tianjin, China c Department of Computer Science, University of Texas at Dallas, Richardson, TX 65080-3021, USA d Texas Instruments, Dallas, TX, USA article info abstract Article history: This paper presents ERELT (Enhanced Radial Edgeless Tree), a tree visualization approach Received 2 June 2015 on modern mobile devices. ERELT is designed to offer a clear visualization of any tree Accepted 5 October 2015 structure with intuitive interaction. Such visualization can assist users in interacting with Available online 22 October 2015 a hierarchical structure such as a media collection, file system, etc. General terms: In the ERELT visualization, a subset of the tree is displayed at a time. The displayed tree Algorithms size depends on the maximum number of tree elements that can be put on the screen Design while maintaining clarity. Users can quickly navigate to the hidden parts of the tree Human factors through touch-based gestures. We have conducted a user study to evaluate this visuali- zation for a music collection. The study results show that this approach reduces the time Keywords: and effort in navigating tree structures for exploration and search tasks.
  • Low RIN Value for RNA-Seq Library Construction from Long-Term Stored Seeds: a Case Study of Barley Seeds

    Low RIN Value for RNA-Seq Library Construction from Long-Term Stored Seeds: a Case Study of Barley Seeds

    G C A T T A C G G C A T genes Technical Note Low RIN Value for RNA-Seq Library Construction from Long-Term Stored Seeds: A Case Study of Barley Seeds Marta Puchta , Maja Boczkowska * and Jolanta Groszyk National Centre for Plant Genetic Resources, Plant Breeding and Acclimatization National Research Institute, Radzików, 05-870 Błonie, Poland; [email protected] (M.P.); [email protected] (J.G.) * Correspondence: [email protected] Received: 20 August 2020; Accepted: 8 October 2020; Published: 13 October 2020 Abstract: Seed aging is a complex biological process and its fundamentals and mechanisms have not yet been fully recognized. This is a key issue faced by research teams involved in the collection and storage of plant genetic resources in gene banks every day. Transcriptomic changes associated with seed aging in the dry state have barely been studied. The aim of the study was to develop an efficient protocol for construction of RNA-Seq libraries from long-term stored seeds with very low viability and low RNA integrity number (RIN). Here, barley seeds that have almost completely lost their viability as a result of long-term storage were used. As a control, fully viable seeds obtained in the course of field regeneration were used. The effectiveness of protocols dedicated to RNA samples with high and low RIN values was compared. The experiment concluded that library construction from low viable or long-term stored seeds with degraded RNA (RIN < 3) should be carried out with extraordinary attention due to the possibility of uneven degradation of different RNA fractions.
  • PD-WP-017 Issue2 (Interpreting Bioanaylzer).Indd

    PD-WP-017 Issue2 (Interpreting Bioanaylzer).Indd

    Interpreting bioanalyzer results for RNA collected using Oragene®•RNA The Agilent Bioanalyzer is an instrument for assessing however, for several reasons, it is more difficult to the “quality” of RNA used for microarray analysis. obtain a high RIN value. As with blood, saliva has a The sharpness of the ribosomal RNA peak and the lower RNA to DNA ratio than that of cultured cells or low baseline between peaks on the electropherogram tissue therefore similar care must be taken to remove generated by the instrument are used as measures of the contaminating DNA. Additionally, saliva is not a integrity of the ribosomal RNA and, by implication, the sterile source of nucleic acid; some of the RNA integrity of messenger RNA. The bioanalyzer uses an contained in saliva originates from oral bacteria. algorithm to generate an “RNA integrity number” (RIN) The ratio between the 16S and 23S bacterial ribosomal that helps researchers decide if the RNA is of sufficiently RNAs is less than the human 18S:28S ratio. The high integrity to proceed with microarray analysis. algorithm used by the bioanalyzer was not designed for use with samples containing both human and Most high quality RNA samples share the same bacterial RNA so the instrument generates a lower common features: RIN that is not indicative of the integrity of the RNA. • distinct 18S and 28S ribosomal peaks Instead of relying on the RIN, a visual assessment of (or 16S and 23S for prokaryotic samples) the electropherogram can provide valuable insight • the absence of smaller peaks between the into the quality of the RNA.
  • Impact of RNA Degradation on Gene Expression Profiling

    Impact of RNA Degradation on Gene Expression Profiling

    Opitz et al. BMC Medical Genomics 2010, 3:36 http://www.biomedcentral.com/1755-8794/3/36 RESEARCH ARTICLE Open Access Impact of RNA degradation on gene expression profiling Lennart Opitz1, Gabriela Salinas-Riester1, Marian Grade2, Klaus Jung3, Peter Jo2, Georg Emons2, B Michael Ghadimi2, Tim Beißbarth3*†, Jochen Gaedcke2† Abstract Background: Gene expression profiling is a highly sensitive technique which is used for profiling tumor samples for medical prognosis. RNA quality and degradation influence the analysis results of gene expression profiles. The impact of this influence on the profiles and its medical impact is not fully understood. As patient samples are very valuable for clinical studies, it is necessary to establish criteria for the RNA quality to be able to use these samples in later analysis. Methods: To investigate the effects of RNA integrity on gene expression profiling, whole genome expression arrays were used. We used tumor biopsies from patients diagnosed with locally advanced rectal cancer. To simulate degradation, the isolated total RNA of all patients was subjected to heat-induced degradation in a time- dependent manner. Expression profiling was then performed and data were analyzed bioinformatically to assess the differences. Results: The differences introduced by RNA degradation were largely outweighed by the biological differences between the patients. Only a relatively small number of probes (275 out of 41,000) show a significant effect due to degradation. The genes that show the strongest effect due to RNA degradation were, especially, those with short mRNAs and probe positions near the 5′ end. Conclusions: Degraded RNA from tumor samples (RIN > 5) can still be used to perform gene expression analysis.
  • Completeview™ Video Client User Manual

    Completeview™ Video Client User Manual

    CompleteView™ Video Client User Manual CompleteView™ Version 4.7 Contents Introduction ................................................................................................................ 1 End User License Agreement ........................................................................................................................1 System Requirements ....................................................................................................................................3 Operation .................................................................................................................... 3 Getting Started ...............................................................................................................................................3 Starting the CompleteView Client ................................................................................................................3 Logging In to the CompleteView Client .......................................................................................................4 The Login Dialog .........................................................................................................................................4 Client Application Update ...........................................................................................................................5 Contacting Video Servers ............................................................................................................................6 Application Overview
  • Assessing Integrity of Insect RNA

    Assessing Integrity of Insect RNA

    Assessing Integrity of Insect RNA Application Note Nucleic Acid Analysis Authors Abstract Jeffrey A. Fabrick and J. Joe Hull Assessing total RNA integrity is important for the success of downstream RNA Pest Management and Biocontrol applications. The Agilent 2100 Bioanalyzer system with the RNA Integrity Number Research Unit, (RIN) provides a quantitative measure of RNA degradation. Although RINs may not Agricultural Research Service, be ascertained for RNA from all organisms, namely those with unusual or complex United States Department of RNA profiles, this Application Note demonstrates the applicability of total RNA Agriculture, quality assessment of different insect species with the 2100 Bioanalyzer system Maricopa, AZ, USA and its relevance to downstream quantitative RT-PCR experiments. Introduction Experimental RNA extraction Total RNA was extracted from insect In general, the success of downstream Materials RNA applications depends on the tissues using a TissueLyser and TRI quality and integrity of the extracted TissueLyser was obtained from Qiagen Reagent. For RNA degradation, tissues total RNA. Therefore, evaluating levels (Valencia, CA, USA). TRI Reagent, were homogenized in 2-mL round-bottom of degradation in RNA samples is OPTIZYME DNase I and a NanoDrop microfuge tubes with two steel critical. Electrophoretic separation and 1000 spectrophotometer were from beads in PBS buffer (700 µL) or TRI visual inspection of the highly abundant Thermo Fisher Scientific (Waltham, Reagent (positive controls), and held ribosomal RNAs (rRNAs) – 16S and MA, USA). An Agilent 2100 Bioanalyzer at room temperature for 0, 5, 10, 30, or 23S in prokaryotes and 18S and 28S in system (G2940CA or G2943CA) and the 60 minutes.
  • Massey Genome Service

    Massey Genome Service

    MASSEY GENOME SERVICE RNA Quality Analysis using Agilent 2100 Bioanalyzer Operational since 2011 BIOANALYZER TECHNICAL INFORMATION BULLETIN January 2017 BULLETIN INCLUDES Checking the quality of RNA Assay Results Details of Bioanalyzer Report Summary Details of Bioanalyzer Service QC Report Enquiries regarding sequencing technical information contact: Xiaoxiao Lin – Acting Laboratory Manager Massey Genome Service Private Bag 11222, Palmerston North 4442, New Zealand Lab +64 6 350 5378 Office +64 6 951 9080 http://genome.massey.ac.nz MASSEY GENOME SERVICE (MGS) RNA Quality Analysis using Agilent 2100 Bioanalyzer and the RNA 6000 Nano Assay TECHNICAL BULLETIN Background This document provides you with information on how to check the quality of your RNA 6000 Nano assay data, and includes information on: Checking the quality of the RNA Ladder used for product sizing Checking the quality of the total RNA profiles and mRNA profiles Massey Genome Service (MGS) provides the following two reports to the customer: Bioanalyzer Report Summary: This report is generated by the Agilent Bioanlyzer 2100 Expert software used for running the instrument. The report is a summary of the quality of your RNA samples and includes the RNA ladder, which is run with each LabChip assay and is used for product sizing. Bioanalyzer Service QC Report: This report is generated by the MGS and is a summary of our services analysis of the data quality. Included with these two reports are the Data Files, which can be opened using the Agilent 2100 expert software. This is the same software used by the MGS for running and analyzing the results. This software can be downloaded from the MGS website at http://genome.massey.ac.nz , by going to the ‘Bioanalyzer Service’ link.
  • RNA-QC-Protocol-2013.Pdf

    RNA-QC-Protocol-2013.Pdf

    SAMPLE MANAGEMENT STANDARD OPERATING PROCEDURE RNA (tube based) QC SOP (For Collaborators) Version Number: 1 Version Date: 5.03.13 Author(s): Jennifer Chiniquy Reviewed/Revised by: Mansi Chovatia, Chia-lin Wei and Shweta Deshpande Summary Before shipping your RNA sample(s), please be sure to follow the JGI sample preparation and sample submission guidelines located at http://my.jgi.doe.gov/general/gettingstarted.html This protocol describes how to perform quality control of RNA samples to evaluate the quantity (Qubit RNA BR Assay) and quality (Agilent Bioanalyzer, RNA 6000 Nano Kit) of your RNA sample(s). We recommend all RNA samples to be evaluated with this protocol before they are shipped to JGI. Materials & Reagents Materials/Reagents/Equipment Supplier/Vendor Stock Number Disposables Qubit assay tubes Q32856 10 ml Serological pipettes 1367811E 0.2 ml PCR 8-tube flex-free strip (RNase-free) 1402-4700 0.2 ml PCR tubes (individual) Ambion/Life Technologies AM12225 Bioanalyzer Cleaning Chips Agilent 5065-9951 Petri Dishes, 100x15 mm, BD Falcon 25373-100 1.5 ml microcentrifuge tubes (RNase-free) Ambion AM12450 Air canister 23022523 Agilent RNA 6000 Nano Kit and Chips (includes syringe for Priming Station) Agilent 5067-1511 Reagents RNase Zap Ambion AM9780 DNA AWAY Surface Decontaminant Fisher Scientific 21-236-28 70% Isopropanol Fisher Scientific 19-130-3860 Nuclease Free Water (10 × 50 ml) Ambion AM9937 Qubit RNA BR Assay Kit Invitrogen Q10211 Equipment 96-well cold block E&K Scientific EK-76120 RNA QC.V1.DOC 1/11 SAMPLE MANAGEMENT STANDARD OPERATING PROCEDURE Bioanalyzer Chip Priming Station Agilent 5065-4401 Chip Vortexer IKA 3617036 2100 Electrophoresis Bioanalyzer Agilent G2939AA Qubit 2.0 Fluorometer Invitrogen Q32866 Thermocycler Applied Biosystems N8050001 Microcentrifuge Eppendorf 022620100 Serological pipettor Eppendorf 022230204 Speed Vac Thermo Fisher SPD1010 EH&S PPE Requirements: Safety glasses, lab coat, and nitrile gloves should be worn at all times while performing this protocol.