Wavesurfer 3000 Oscilloscope Getting Started Guide
Total Page:16
File Type:pdf, Size:1020Kb
WaveSurfer 3000 Getting Started Guide 700 Chestnut Ridge Road Chestnut Ridge, NY 10977 1.800.5.LECROY • teledynelecroy.com WaveSurfer 3000 Getting Started Guide © 2015 Teledyne LeCroy, Inc. All rights reserved. Unauthorized duplication of Teledyne LeCroy documentation materials other than for internal sales and distribution purposes is strictly prohibited. However, clients are encouraged to distribute and duplicate Teledyne LeCroy documentation for their own internal educational purposes. WaveSurfer, WaveScan and Teledyne LeCroy are trademarks of Teledyne LeCroy. Windows is a registered trademark of Microsoft Corporation. Other product or brand names are trademarks or requested trademarks of their respective holders. Information in this publication supersedes all earlier versions. Specifications are subject to change without notice. 926057-00 July, 2015 WaveSurfer 3000 Getting Started Guide Welcome Thank you for buying a Teledyne LeCroy product. We’re certain you’ll be pleased with the detailed features unique to our instruments. This Getting Started Guide is designed to cover important oscilloscope safety and installation information along with some basic operating procedures so you’re quickly working with waveforms. Contents Introduction Basics About the WaveSurfer 3000 Oscillosocopes 2 Vertical 24 Specifications 3 Horizontal (Timebase) 26 Materials List 3 Triggers 27 General Safety Information 4 Cursors 28 Support 5 Zoom 29 Measurements & Statistics 30 Set Up Math 31 The Front of Your Oscilloscope 8 Memories (Reference Waveforms) 32 The Back of Your Oscilloscope 10 WaveSource 33 Carrying 11 Documenting 34 Powering On/Off 11 Temperature Dependent Calibration 34 Connecting 11 Software Options 35 Micro SD Card 12 Probes 12 Reference Digital Leadset 13 Service 38 Software Activation 14 Teledyne LeCroy Service Centers 39 Firmware Updates 14 Certifications 40 Warranty 42 User Interface Windows License Agreement 42 Touch Screen Display 16 Changing the Display 18 Working With Traces 18 Entering/Selecting Data 20 Front Panel 21 INTRODUCTION WaveSurfer 3000 INTRODUCTION About the WaveSurfer 3000 Oscillosocopes WaveSurfer 3000 oscilloscopes feature the MAUI advanced user interface Capture, Debug, Analyze, Document with touch screen simplicity to shorten debug time. Quickly identify and The advanced active probe interface gives tremendous flexibility for isolate anomalies with WaveScan, Fast Display, and History mode for capturing all types of signals. Debug, analyze and document problems faster troubleshooting; LabNotebook enables easy documentation and through the use of powerful math and measurement capabilities, convenient collaboration. The advanced probeinterface, upgradable Pass/Fail mask testing, sequence mode segmented memory, and bandwidth and multi-instrument capabilities provide maximum versatility LabNotebook report generator. and investment protection. Multi-Instrument Capabilities MAUI - A New Wave of Thinking Beyond traditional oscilloscope functionality the WaveSurfer 3000 has MAUI is the most advanced oscilloscope user interface. MAUI is designed a variety of multi-instrument capabilities including waveform generation for touch; all important oscilloscope controls are accessed through the through a built-in function generator with arbitrary waveform capabilities, intuitive touch screen. MAUI is made for simplicity; time saving shortcuts protocol analysis with serial data trigger and decode, a digital voltmeter, and intuitive dialogs simplify setup. MAUI is built to solve; deep set of and logic analysis with an available 16-channel mixed signal option. debug and analysis tools help identify problems and find solutions quickly. Advanced Anomaly Detection Combining a fast waveform update rate of 130,000 waveforms/second with History mode waveform playback and WaveScan search and find, the WaveSurfer 3000 is an outstanding tool for waveform anomaly detection. 2 INTRODUCTION Specifications Materials List Detailed specifications are maintained in the Datasheet on the product Check that you have all the parts listed here. Contact Teledyne LeCroy page at teledynelecroy.com. immediately if any part is missing. • 1 oscilloscope Key Specifications • 2 or 4 passive probes (one for each channel) Bandwidth 200 MHz – 750 MHz • 1 Micro SD Card (installed) Channels 2 or 4 • 1 AC power cord (rated for country) Sample Rate (all channels) 2 GS/s • 1 protective front cover Memory (per channel) 10 Mpts/ch • 1 Getting Started Guide Digital Channels 16 • 1 Oscilloscope Registration Card Digital Sample Rate 500 MS/s • 1 Calibration Document Minimum Detectable Pulse Width 4 ns • 1 CE Certificate Maximum Input Frequency 125 MHz WaveSurfer 3000 Getting Started Guide 3 INTRODUCTION General Safety Information Precautions This section contains instructions that must be observed to keep the • Use proper power cord. Use only the power cord shipped with this instrument operating in a correct and safe condition. You are required to instrument and certified for the country of use. follow generally accepted safety procedures in addition to the precautions Maintain ground. This product is grounded through the power cord specified in this section. The overall safety of any system incorporating • grounding conductor. To avoid electric shock, connect only to a this instrument is the responsibility of the assembler of the system. grounded mating outlet. Symbols • Connect and disconnect properly. Do not connect/disconnect probes These symbols appear on the instrument’s front or rear panels and in its or test leads while they are connected to a voltage source. documentation to alert you to important safety considerations. • Observe all terminal ratings. Do not apply a voltage to any input (C1, CAUTION of damage to instrument, or WARNING of hazard to C2, C3, C4, EXT or Dig) that exceeds the maximum rating of that input. health. Attend to the accompanying information to protect against Refer to the front of the oscilloscope for maximum input ratings. personal injury or damage. Do not proceed until conditions are fully • Use only within operational environment listed. Do not use in wet or understood and met. explosive atmospheres. Use indoors only. WARNING. Risk of electric shock. • • Keep product surfaces clean and dry. Measurement ground connection. • Do not block the cooling vents. Leave a minimum six-inch gap between the instrument and the nearest object. Alternating Current. • Do not remove the covers or inside parts. Refer all maintenance to On/Standby power. qualified service personnel. • Do not operate with suspected failures. Inspect all parts regularly and do not use the product if any part is damaged. Cease operation immediately and sequester the instrument from inadvertent use. 4 INTRODUCTION Operational Environment Fuse Replacement Temperature: 0° to 50° C Disconnect the power cord before inspecting or replacing the fuse. Open Humidity: Maximum relative humidity 90% for temperatures up to the fuse holder (located at the rear of the instrument below the AC power 31° C decreasing linearly to 50% relative humidity at 50° C inlet) using a small, flat-bladed screwdriver. Replace the old fuse with a Altitudes: up to 3,048 m (at < 30° C) new 5 x 20 mm T-rated 3.15 A/250 V fuse. Close the fuse holder before powering on. Power and Ground Connections WARNING. For continued fire protection at all line voltages, replace The instrument operates from a single-phase, 100 to 240 Vrms (± 10%) the fuse with one of the specified type and rating only. Always AC power source at 50/60 Hz (± 5%), or a 100 to 120 Vrms (± 10%) AC disconnect the power cord before replacing the fuse. power source at 400 Hz (± 5%). The instrument automatically adapts to the line voltage. Manual voltage selection is not required. The AC inlet ground is connected directly to the frame of the instrument. Support For adequate protection again electric shock, connect to a mating outlet with a safety ground contact. Online Documentation Teledyne LeCroy publishes a free Technical Library on its website. WARNING. Interrupting the protective conductor inside or outside Manuals, tutorials, application notes, white papers, and videos are the oscilloscope, or disconnecting the safety ground terminal, available to help you get the most out of your Teledyne LeCroy products. creates a hazardous situation. Intentional interruption is prohibited. The WaveSurfer 3000 Oscillosocopes Operator’s Manual can be Maximum power consumption with all accessories installed (e.g., active downloaded from teledynelecroy.com/support/techlib. This .PDF probes, USB peripherals, digital leadsets) is 150 W (150 VA) for four- document contains more extensive procedures for operating your channel models and 100 W (100 VA) for two-channel models. Power oscilloscope than are found here. consumption in standby mode is 4 W. The Datasheet published on the product page contains the detailed Cleaning product specifications. Clean only the exterior of the oscilloscope using a damp, soft cloth. Do not use harsh chemicals or abrasive elements. Under no circumstances Technical Support submerge the instrument or allow moisture to penetrate it. Avoid electric Registered users can contact their local Teledyne LeCroy service center shock by unplugging the power cord from the AC outlet at the number listed in this guide to make Technical Support requests by before cleaning. phone or email. You can also submit Technical Support requests via the website at teledynelecroy.com/support/techhelp. CAUTION. Do not attempt to clean internal parts. WaveSurfer