Digital Storage Oscilloscope Instrument

Total Page:16

File Type:pdf, Size:1020Kb

Digital Storage Oscilloscope Instrument • Unique split window function. Power Cord for the United Kingdom • Flexible application modules. SAFETY INSTRUCTIONS GETTING STARTED • Three standard input impedances When using the instrument in the United Kingdom, (50Ω/75Ω/1MΩ). make sure the power cord meets the following safety This section contains the basic safety symbols that may The Getting started chapter introduces the • Optional power measurement instructions. appear on the accompanying User Manual CD or on the oscilloscope's main features, appearance, and set up functions are available for fast Digital Storage Oscilloscope instrument. For detailed safety instructions and procedure. analysis of power quality tests. precautions, please see the Safety Instructions chapter NOTE: This lead/appliance must only be wired by • Optional analysis software for I2C, competent persons. in the user manual CD. Main Features SPI and UART serial signal GDS-3000 Series triggering and decoding. Safety Symbols WARNING: THIS APPLIANCE MUST BE EARTHED Model name Frequency bandwidth Input channels • 2 and 4 channel models available IMPORTANT: The wires in this lead are coloured in GDS-3152 150MHz 2 up to 500 MHz. These safety symbols may appear in the user manual or accordance with the following code: GDS-3252 250MHz 2 • Large 8” color TFT LCD, on the instrument. GDS-3352 350MHz 2 supporting a large 8 x 10 graticule. Green/ Yellow: Earth Warning: Identifies conditions or GDS-3502 500MHz 2 • On-screen Help. Blue: Neutral practices that could result in injury or GDS-3154 150MHz 4 • 64 MB internal flash memory. Brown: Live (Phase) • FreeWave remote control software Warning loss of life. GDS-3254 250MHz 4 As the colours of the wires in main leads may not correspond with (free download). GDS-3354 350MHz 4 Caution: Identifies conditions or the coloured marking identified in your plug/appliance, proceed as • USB host port: front and rear panel, Interface practices that could result in damage follows: GDS-3504 500MHz 4 for storage devices. The wire which is coloured Green & Yellow must be connected to QUICK START GUIDE to the instrument or to other the Earth terminal marked with either the letter E, the earth symbol Performance • USB slave port(Optional GPIB to Caution properties. • High sampling rate: up to 5GSa/s GW INSTEK PART NO. 82DS-33040MD1 or coloured Green/Green & Yellow. real-time (4GSa/s GDS-350X), USB), RS-232C port: for remote The wire which is coloured Blue must be connected to the terminal 100GSa/s equivalent-time. control. DANGER High Voltage which is marked with the letter N or coloured Blue or Black. • Calibration output. The wire which is coloured Brown must be connected to the terminal • Deep memory: 25k points record marked with the letter L or P or coloured Brown or Red. length. • Go-No Go output. Attention Refer to the Manual If in doubt, consult the instructions provided with the equipment or • Minimum 2ns peak detection. • Trigger output. contact the supplier. • Ethernet port. This cable/appliance should be protected by a suitably rated and Features • 2 and 4 channel models. approved HBC mains fuse: refer to the rating information on the Protective Conductor Terminal • Bandwidth up to 500 MHz. equipment and/or user instructions for details. As a guide, a cable of Package Contents and Accessories 0.75mm2 should be protected by a 3A or 5A fuse. Larger conductors • 5GSa/s (200ps resolution) real-time Earth (ground) Terminal would normally require 13A types, depending on the connection sampling rate (4GSa/s, 250ps method used. resolution for GDS-350X). Standard Accessories Do not dispose electronic equipment Any exposed wiring from a cable, plug or connection that is engaged • 100GSa/s equivalent sample rate. Item Part Number as unsorted municipal waste. Please in a live socket is extremely hazardous. If a cable or plug is deemed hazardous, turn off the mains power and remove the cable, any • VPO waveform processing. User Manual CD use a separate collection facility or fuses and fuse assemblies. All hazardous wiring must be • Large 8’’ 800 x 600 high-resolution Quick Start Guide (this document) contact the supplier from which this immediately destroyed and replaced in accordance to the above ISO-9001 CERTIFIED MANUFACTURER Power Cord x1 Region Dependent instrument was purchased. standard. TFT LCD. 1 2 3 4 9. Rear stand 10. Power input socket Optional Accessories Driverss Description USB driver LabVIEW driver 1. Print /Save key 2. Variable knob and 11. Fan 12. Key lock Item Part Number Select key 13. Calibration output Instrument cart, 470(W) x GTC-001 3. Function keys 4. Split window cluster 430(D)mm (U.S. type input socket) Display and Panel Overview Instrument cart, 330(W) x GTC-002 5. Trigger controls 6. Horizontal controls Setting up the Oscilloscope 430(D)mm (U.S. type input socket) Display Overview 7. EXT trigger input (2CH 8. Vertical controls This section describes how to set up the oscilloscope test lead, BNC to BNC heads GTL-110 Acquistion mode only) Memory bar properly including setting the stand, installing the RS-232C cable, 9-pin Female to 9- GTL-232 9. Math, Reference & Bus 10. CH1~4 input optional modules and compensating the probe. pin female, Null modem for keys computer Trigger Trigger Dat e and 11. USB Probe 12. Power button USB cable, USB2.0A-B type cable GTL-246 position status time compensation, Ground Tilting the Stand 4P port Demoboard for the GDS-3000 GDB-03 Upright Turn the legs under the casing as shown Trigger 13. Bottom menu keys 14. Menu key Series DSO Channel Waveform level below to have the instrument sit upright. 25MHz high voltage differential GDP-025 indicat or 15. Side menu keys 16. LCD probe 50MHz high voltage differential GDP-050 Horizontal Signal Rear Panel probe Channel status status frequency 100MHz high voltage differential GDP-100 13 1 2 3 4 5 6 7 probe 5A/ 40Hz~1kHz current probe GCP-005 8 200A/40Hz~10kHz current probe GCP-020 Automatic measurements Trigger configuration Tilt To tilt, tilt the legs back behind the 100A/DC~100kHz current probe GCP-100 casing, as shown below. This manual contains proprietary information, which is 50MHz/ 30A current probe GCP-530 Front Panel protected by copyright. All rights are reserved. No part 100MHz/ 30A current probe GCP-1030 of this manual may be photocopied, reproduced or Power supply for current probe GCP-206P 16 2 3 4 5 translated to another language without prior written (2 input channels) Digital Sto rage Oscillo scope VARIABLE T RI GG E R GDS -3352 350 M H z 5 GS/s Visual Persistence Oscil loscope LEVEL Au toset Pr i n t Power supply for current probe GCP-425P Ru n /St o p consent of Good Will Corporation. Sa ve Se lect S p lit 1 W in dow M enu Si ngl e De fa u lt M easur e Cu rso r Test Acq uire 50 % (4 input channels) S e tu p The information in this manual was correct at the time Displ ay He lp Sa ve/Re call Ut i lit y For ce - T r ig A u to -Ra nge Passive probe; 150 MHz,10X with GTP-151R VERTICA L HO RIZONTAL 12 11 10 9 of printing. However, Good Will continues to improve 15 P OSIT I ON P OSIT I ON P OSIT I ON M ATH readout M AC 50W AC 50W REF BW 75W BW 75W its products and therefore reserves the right to change 13 R CH 1 BUS CH 2 Zoo m M enu Passive probe; 250 MHz, 10X with GTP-251R 14 O ff B1 6 Description VOLTS /DI V VOLTS /DI V TIME /DIV First Time Use the specifications, equipment, and maintenance B2 readout 1. Trigger output 2. Go-NoGo output procedures at any time without notice. 2V CH1 CH2 EXT TRIG Passive probe; 350 MHz, 10X with GTP-351R POWER 1MW 15pF 1MW 15pF 300 Vrms MAX. 300 Vrms MAX. 3. Video out 4. RS232 Output 50 W & 75 W 50 W & 75 W This section describes how to connect a signal, adjust 5 Vrms MAX. 5 Vrms MAX. readout CAT CAT 7 5. Line out 6. LAN port the scale, and compensate the probe. Before operating Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng Passive probe, 500MHz, 10X with GTP-501R 12 11 10 9 8 the GDS-3000 in a new environment, run these steps to Dist., New Taipei City 236, Taiwan. readout 7. Ground strap connector 8. USB Device/Host port 5 6 7 8 make sure the instrument performs at its full potential. Common Specifications Type Edge, Pulse Width(Glitch), Video, Pulse Runt, Rise & Fall(Slope), Alternate, 1. Power the GDS-3000 on. PECIFICATIONS Vertical Event-Delay(1~65535 events), Time- S Delay(Duration)(10ns~10s), I2C*, SPI*, 2. Set the date and time. Resolution 8 bit UART* The specifications apply when the oscilloscope is Sensitivity @1MΩ: 2mV~5V/div 3. Reset the system by recalling the factory *optional @50/75Ω: 2mV~1V/div powered on for at least 30 minutes under +20°C~+30°C. settings. Press the Default Setup key on Input Coupling AC, DC, GND Runt:Trigger on a pulse that crosses one the front panel. threshold but fails to cross a second Model Specific Specifications Input Impedance 1MΩ// 15pF DC Gain Accuracy ±3% full scale threshold before crossing the first again. 4. Install optional software. The optional software Polarity Normal & Invert SPI (optional):Trigger on SS, MOSI, packages (Power Analysis, Serial Bus Decode) can GDS-3152 & GDS-3154 Maximum Input @1MΩ: 300Vrms, CAT I MISO, or MOSI and MISO on SPI buses.
Recommended publications
  • An Oscilloscope Correction Method for Vector-Corrected RF Measurements
    This article has been accepted for inclusion in a future issue of this journal. Content is final as presented, with the exception of pagination. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 1 An Oscilloscope Correction Method for Vector-Corrected RF Measurements Sebastian Gustafsson, Student Member, IEEE, Mattias Thorsell, Member, IEEE, Jörgen Stenarson, Member, IEEE, and Christian Fager, Member, IEEE Abstract— The transfer characteristics of the RF front-end circuit components. As these errors must be compensated for circuitry of a real-time oscilloscope (RTO) are not only frequency to achieve accurate signal sampling [4], several correction dependent and nonlinear with signal amplitude but also depen- techniques have been introduced [5], [6]. Other correction dent on the voltage range setting of the oscilloscope. A correction table in the frequency domain is proposed to account for the techniques have also been introduced [7]–[12], but they are additional gain and delay introduced when switching between only valid for sampling oscilloscopes. Previous research different voltage ranges. The table was extracted from the has focused on correction techniques for a certain set of measured data in which a continuous-wave signal source was instrument settings, e.g., a particular voltage range. Hence, connected to the oscilloscope ports, whereas the input power, the changing the settings would make the correction invalid. frequency, and voltage ranges were varied. The importance of the corrections is demonstrated by its use in an RTO-based two-port However, changing the range is desirable in some applications, vector-corrected measurement system. Measurements from the to fully utilize the voltage range of the ADC.
    [Show full text]
  • Future of Vector Network Analysis Dylan Williams and Nate Orloff Integrated Circuits Drive Wireless Communications
    Future of Vector Network Analysis Dylan Williams and Nate Orloff Integrated Circuits Drive Wireless Communications Application Frequency (GHz) 10 30 100 300 1000 100 10 Transit Frequency (GHz) Frequency Transit 1990 1995 2000 2005 2010 2015 2020 Year We Cannot Take the Integrated Circuit for Granted at mmWaves 2 Next 15 Years of Wireless Manufacturing by Country The United States still dominates mmWave manufacturing Enables $12.3T in Total Economic Growth (2020-2035) Communication Providers Want Speed of Fiber on Your Phone Millimeter-Waves are the Next Wireless Frontier Measurements and Calibrations Matter at mmWaves Before Calibration 64 QAM at 44 GHz After Calibration mmWave Measurement Challenge of our Era Not a Single RF Connector! On-Wafer IC and System-Level Test OTA System-Level Test Transistor models IC Test System-Level Test End-to-End Verification On-Wafer Connectorized Free-Space Goals for Vector Network Analysis in CTL Project Calibration Reference Planes On-Wafer and to OTA Test On-Wafer Measurements • Innovations in Calibration • Support Device Models to System-Level Test • State-Of-The-Art Instruments for US mmWave NR Manufacturers Vector Network Analysis • Platform for Traceable System-Level Tests Across CTL • Close the Connector-Less Gap mmWave Design Extremely Complex Accurate measurements are a must 80 80 GHz GHz 160 ~ GHz 240 GHz • Highly nonlinear operating states required for efficiency • Characterize, capture, control and reuse harmonics • Must maintain linearity On-Wafer Measurement the Only Way to Test ICs Yesterday
    [Show full text]
  • P50xxa Streamline Series Vector Network Analyzer 2/4-Port up to 53 Ghz
    P50xxA Streamline Series Vector Network Analyzer 2/4-port Up to 53 GHz. 2/4/6-port Up to 20 GHz Compact Form. Zero Compromise. P5000A/P5020A 9 kHz to 4.5 GHz P5001A/P5021A 9 kHz to 6.5 GHz P5002A/P5022A 9 kHz to 9 GHz P5003A/P5023A 9 kHz to 14 GHz P5004A/P5024A 9 kHz to 20 GHz P5005A/P5025A 100 kHz to 26.5 GHz P5006A/P5026A 100 kHz to 32 GHz P5007A/P5027A 100 kHz to 44 GHz P5008A/P5028A 100 kHz to 53 GHz Find us at www.keysight.com Page 1 Keysight P500xA and P502xA Streamline Series VNA The freedom of portable network analysis doesn’t have to mean a compromise in performance. The P50xxA Series brings high-end performance and flexibility to the portable Keysight Streamline Series. Gain confidence in your measurements with best-in-class performance offering fast, reliable, and repeatable results. Explore the complete characterization of your devices with a rich portfolio of software applications that transform the compact network analyzer into a complete RF measurement solution. The P50xxA Series, a member of Keysight’s Streamline Series offers the performance required for testing passive components, amplifiers, mixers or frequency converters. The vector network analyzer (VNA) provides best-in-class key specifications such as dynamic range, measurement speed, trace noise and temperature stability. Choose from 2- or 4-port models up to 53 GHz, or 2-, 4- or 6-port models up to 20 GHz. The VNA is packaged in a compact chassis and controlled by an external computer with powerful data processing capabilities and functionalities.
    [Show full text]
  • 10 Factors in Choosing a Basic Oscilloscope 10 Factors in Choosing a Basic Oscilloscope Contents Intro 1 2 3 4 5 6 7 8 9 10 11 Contact 2
    10 FACTORS IN CHOOSING A BASIC OSCILLOSCOPE 10 FACTORS IN CHOOSING A BASIC OSCILLOSCOPE CONTENTS INTRO 1 2 3 4 5 6 7 8 9 10 11 CONTACT 2 10 Factors in Choosing a Basic Oscilloscope There are several ways to navigate this interactive PDF document: Click on the table of contents (page 3) Basic oscilloscopes are used as windows into signals for troubleshooting Use the navigation at the top of each page to jump circuits or checking signal quality. They generally come with bandwidths to sections or use the page forward/back arrows from around 50 MHz to 200 MHz and are found in almost every design lab, Use the arrow keys on your keyboard education lab, service center and manufacturing cell. Use the scroll wheel on your mouse Whether you buy a new scope every month or every five years, this guide will Left click to move to the next page, right click to move to the previous page (in full-screen mode only) give you a quick overview of the key factors that determine the suitability of a Click on the icon ß to enlarge the image. basic oscilloscope to the job at hand. The digital storage oscilloscope Oscilloscopes are the basic tool for anyone designing, manufacturing or repairing electronic equipment. A digital storage oscilloscope (DSO, on which this guide concentrates) acquires and stores waveforms. The waveforms show a signal’s voltage and frequency, whether the signal is distorted, timing between signals, how much of a signal is noise, and much, much more. 10 FACTORS IN CHOOSING A BASIC OSCILLOSCOPE CONTENTS INTRO 1 2 3 4 5 6 7 8 9 10 11
    [Show full text]
  • Oscilloscope & Multimeter
    INSTRUCTION OVERVIEW FOR Oscilloscope & Multimeter Stock No.64573 Part No.O20M/3C IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent holder of the product. Read all these instructions before assembling, operating or maintaining this product. This manual has been compiled by Draper Tools describing the purpose for which the product has been designed, and contains all the necessary information to ensure its correct and safe use. By following all the general safety instructions contained in this manual, it will ensure both product and operator safety, together with longer life of the product itself. AlI photographs and drawings in this manual are supplied by Draper Tools to help illustrate the operation of the product. Whilst every effort has been made to ensure the accuracy of information contained in this manual, the Draper Tools policy of continuous improvement determines the right to make modifications without prior warning. 1. TITLE PAGE 1.1 INTRODUCTION: USER MANUAL FOR: OSCILLOSCOPE & MULTIMETER Stock no. 64573 Part no. O20M/3C 1.2 REVISIONS: Date first published March 2015 As our user manuals are continually updated, users should make sure that they use the very latest version. Downloads are available from: http://www.drapertools.com/b2c/b2cmanuals.pgm DRAPER TOOLS LIMITED WEBSITE: drapertools.com HURSLEY ROAD PRODUCT HELPLINE: +44 (0) 23 8049 4344 CHANDLER’S FORD GENERAL FAX: +44 (0) 23 8026 0784 EASTLEIGH HAMPSHIRE SO53 1YF UK 1.3 UNDERSTANDING THIS MANUALS SAFETY CONTENT: WARNING! Information that draws attention to the risk of injury or death.
    [Show full text]
  • Voltage and Power Measurements Fundamentals, Definitions, Products 60 Years of Competence in Voltage and Power Measurements
    Voltage and Power Measurements Fundamentals, Definitions, Products 60 Years of Competence in Voltage and Power Measurements RF measurements go hand in hand with the name of Rohde & Schwarz. This company was one of the founders of this discipline in the thirties and has ever since been strongly influencing it. Voltmeters and power meters have been an integral part of the company‘s product line right from the very early days and are setting stand- ards worldwide to this day. Rohde & Schwarz produces voltmeters and power meters for all relevant fre- quency bands and power classes cov- ering a wide range of applications. This brochure presents the current line of products and explains associated fundamentals and definitions. WF 40802-2 Contents RF Voltage and Power Measurements using Rohde & Schwarz Instruments 3 RF Millivoltmeters 6 Terminating Power Meters 7 Power Sensors for URV/NRV Family 8 Voltage Sensors for URV/NRV Family 9 Directional Power Meters 10 RMS/Peak Voltmeters 11 Application: PEP Measurement 12 Peak Power Sensors for Digital Mobile Radio 13 Fundamentals of RF Power Measurement 14 Definitions of Voltage and Power Measurements 34 References 38 2 Voltage and Power Measurements RF Voltage and Power Measurements The main quality characteristics of a parison with another instrument is The frequency range extends from DC voltmeter or power meter are high hampered by the effect of mismatch. to 40 GHz. Several sensors with differ- measurement accuracy and short Rohde & Schwarz resorts to a series of ent frequency and power ratings are measurement time. Both can be measures to ensure that the user can required to cover the entire measure- achieved through utmost care in the fully rely on the voltmeters and power ment range.
    [Show full text]
  • Lab 1 – Measurements of Frequency
    Physics of Music PHY103 Lab Manual Lab 1 – Measurements of Frequency EQUIPMENT and PREPARATION Part A: • Oscilloscopes (get 5 from teaching lab) • BK Precision function generators (get 5 from Thang or teaching lab) • Counter/timers (PASCO, 4 + 1 other) • Connectors and cables (BNC to BNC’s, banana plug pairs) connecting function/signal generators to oscilloscopes and speaker. • BNC to 2 leads • Adaptors: mike to BNC so that output of preamps can be looked at on oscilloscope. • BNC to banana adapters • BNC T- adapters • Oscilloscope probes • Pasco open speakers • Microphones, preamps, mic stands • Strobes (3) optional Warning: do not place speakers near oscilloscope screens as they can damage the CRT (cathode ray tube) screens. Note: The professor will attempt to have the equipment out and available for the labs. However the TAs/TIs should check that the equipment is ready to use, that every lab setup has all the necessary equipment. The TA/TIs should also be familiar with the lab and know how to troubleshoot the equipment. INTRODUCTION In this lab, we will be measuring the frequency of a signal using three different methods. The first method involves the use of the function generator. A function generator is an instrument that can produce sine, square, and triangular waves at a given frequency. The second method makes use of the oscilloscope. An oscilloscope is an instrument principally used to display signals as a function of time. The final method for measuring the frequency uses the counter/timer. A counter/timer is an instrument that can give a very accurate measurement of the frequency of a signal by counting each time a voltage crosses a particular value.
    [Show full text]
  • The Oscilloscope and the Function Generator: Some Introductory Exercises for Students in the Advanced Labs
    The Oscilloscope and the Function Generator: Some introductory exercises for students in the advanced labs Introduction So many of the experiments in the advanced labs make use of oscilloscopes and function generators that it is useful to learn their general operation. Function generators are signal sources which provide a specifiable voltage applied over a specifiable time, such as a \sine wave" or \triangle wave" signal. These signals are used to control other apparatus to, for example, vary a magnetic field (superconductivity and NMR experiments) send a radioactive source back and forth (M¨ossbauer effect experiment), or act as a timing signal, i.e., \clock" (phase-sensitive detection experiment). Oscilloscopes are a type of signal analyzer|they show the experimenter a picture of the signal, usually in the form of a voltage versus time graph. The user can then study this picture to learn the amplitude, frequency, and overall shape of the signal which may depend on the physics being explored in the experiment. Both function generators and oscilloscopes are highly sophisticated and technologically mature devices. The oldest forms of them date back to the beginnings of electronic engineering, and their modern descendants are often digitally based, multifunction devices costing thousands of dollars. This collection of exercises is intended to get you started on some of the basics of operating 'scopes and generators, but it takes a good deal of experience to learn how to operate them well and take full advantage of their capabilities. Function generator basics Function generators, whether the old analog type or the newer digital type, have a few common features: A way to select a waveform type: sine, square, and triangle are most common, but some will • give ramps, pulses, \noise", or allow you to program a particular arbitrary shape.
    [Show full text]
  • Experiment No. 3 Oscilloscope and Function Generator
    Experiment No. 3 Oscilloscope and Function Generator An oscilloscope is a voltmeter that can measure a fast changing wave form. Wave forms A simple wave form is characterized by its period and amplitude. A function generator can generate different wave forms. 1 Part 1 of the experiment (together) Generate a square wave of frequency of 1.8 kHz with the function generator. Measure the amplitude and frequency with the Fluke DMM. Measure the amplitude and frequency with the oscilloscope. 2 The voltage amplitude has 2.4 divisions. Each division means 5.00 V. The amplitude is (5)(2.4) = 12.0 V. The Fluke reading was 11.2 V. The period (T) of the wave has 2.3 divisions. Each division means 250 s. The period is (2.3)(250 s) = 575 s. 1 1 f 1739 Hz The frequency of the wave = T 575 10 6 The Fluke reading was 1783 Hz The error is at least 0.05 divisions. The accuracy can be improved by displaying the wave form bigger. 3 Now, we have two amplitudes = 4.4 divisions. One amplitude = 2.2 divisions. Each division = 5.00 V. One amplitude = 11.0 V Fluke reading was 11.2 V T = 5.7 divisions. Each division = 100 s. T = 570 s. Frequency = 1754 Hz Fluke reading was 1783 Hz. It was always better to get a bigger display. 4 Part 2 of the experiment -Measuring signals from the DVD player. Next turn on the DVD Player and turn on the accessory device that is attached to the top of the DVD player.
    [Show full text]
  • Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science
    Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science 6.002 - Circuits and Electronics Fall 2004 Lab Equipment Handout (Handout F04-009) Prepared by Iahn Cajigas González (EECS '02) Updated by Ben Walker (EECS ’03) in September, 2003 This handout is intended to provide a brief technical overview of the lab instruments which we will be using in 6.002: the oscilloscope, multimeter, function generator, and the protoboard. It incorporates much of the material found in the individual instrument manuals, while including some background information as to how each of the instruments work. The goal of this handout is to serve as a reference of common lab procedures and terminology, while trying to build technical intuition about each instrument's functionality and familiarizing students with their use. Students with previous lab experience might find it helpful to simply skim over the handout and focus only on unfamiliar sections and terminology. THE OSCILLOSCOPE The oscilloscope is an electronic instrument based on the cathode ray tube (CRT) – not unlike the picture tube of a television set – which is capable of generating a graph of an input signal versus a second variable. In most applications the vertical (Y) axis represents voltage and the horizontal (X) axis represents time (although other configurations are possible). Essentially, the oscilloscope consists of four main parts: an electron gun, a time-base generator (that serves as a clock), two sets of deflection plates used to steer the electron beam, and a phosphorescent screen which lights up when struck by electrons. The electron gun, deflection plates, and the phosphorescent screen are all enclosed by a glass envelope which has been sealed and evacuated.
    [Show full text]
  • Function Generator and Oscilloscope
    Summer 2007 Lab 2 EE100/EE43 EECS 100/43 Lab 2 – Function Generator and Oscilloscope 1. Objective In this lab you learn how to use the oscilloscope and function generator 2. Equipment a. Breadboard b. Wire cutters c. Wires d. Oscilloscope e. Function Generator f. 1k resistor x 2 h. Various connectors (banana plugs-to-alligator clips) for connecting breadboard to power supply and for multimeter connections. 3. Theory a. The HP33120A Function Generator The front panel of your function generator is shown in Figure 1. This instrument outputs a time-varying periodic voltage signal (the OUTPUT connector, do not use the sync connector, refer to figure 2). By pushing the appropriate buttons on the front panel, the user can specify various characteristics of the signal. Figure 1. Front panel of your function generator (Ref: Agilent Function Generator User’s Guide #33120-90006) University of California, Berkeley Department of EECS Summer 2007 Lab 2 EE100/EE43 Figure 2. Make sure you use BLACK BNC input cables. Connect them to the OUTPUT terminal as shown above. Do not use the SYNC connector The main characteristics that you will be concerned with in this class are: • Shape: sine, square, or triangle waves. • Frequency: inverse of the period of the signal; units are cycles per second (Hz) • Vpp: peak to peak Voltage value of the signal • DC Offset: constant voltage added to the signal to increase or decrease its mean or average level. In a schematic, this would be a DC voltage source in series with the oscillating voltage source. Figure 3 below illustrates a couple of the parameters above.
    [Show full text]
  • M980xa Series Pxie Vector Network Analyzer 9 Khz to 20 Ghz/100 Khz to 53 Ghz
    M980xA Series PXIe Vector Network Analyzer 9 kHz to 20 GHz/100 kHz to 53 GHz Drive down the size of test M9800A 9 kHz to 4.5 GHz M9801A 9 kHz to 6.5 GHz M9802A 9 kHz to 9 GHz M9803A 9 kHz to 14 GHz M9804A 9 kHz to 20 GHz M9805A 100 kHz to 26.5 GHz M9806A 100 kHz to 32 GHz M9807A 100 kHz to 44 GHz M9808A 100 kHz to 53 GHz Find us at www.keysight.com Page 1 M980xA Series PXIe Vector Network Analyzer As the margins for multiport devices become tighter, your test equipment needs to be one step ahead. The Keysight M980xA PXIe Vector Network Analyzer (VNA) meets the most demanding multiport challenges with a true multiport architecture that offers exceptional performance no matter how many ports you use. Gain deeper insights into your devices with the widest available portfolio of measurement applications for PXI VNAs, including spectrum analysis, noise figure measurements, and more. The M980xA Series offers the performance required for testing passive components, amplifiers, mixers or frequency converters. It provides best-in-class key PXI VNA specifications such as dynamic range, measurement speed, trace noise and temperature stability. Each module is a completely independent vector network analyzer with 2-, 4- or 6-ports up to 20 GHz, or 2-ports up to 53 GHz. The modules are easily configured as a true multiport VNA by using additional modules installed in the same chassis, and a VNA with up to 50-ports can be configured in a single chassis for multiport applications.
    [Show full text]