NFPA 704 Placard Guidelines WFPD.Pdf WOODSIDE FIRE PROTECTION DISTRICT NFPA 704 Placard Guidelines January 2020 808 Portola Rd. #C Portola Valley, CA 94028 Fire Prevention 650-423-1405 Fax 650-851-3960 NFPA 704 Placards are required for any business or commercial building that has a quantity of hazardous materials equal to or greater than a total weight of 500 pounds solid, 55 gallons liquid, 200 cubic feet of gas or where a radioactive product is used, stored or handled. Placards may also be required where the hazardous materials could present a hazard to emergency responders. Placards provide emergency responders notification of potential hazards that may increase their risk while entering into a building, room or storage area. You may be required to place a placard on the outside and/or the inside of your business. Placards are designed to warn of health, flammability, reactivity or special hazards that may exist. Placards will be 16 inches square on outside locations and 12 inches square on inside locations. Listed below are the some of the most common materials used in commercial applications. Refer to your MSDS sheets for those not on this list. FLAMMABILITY Example of placard for Oxygen 0 HEALTH 1 0 REACTIVITY OXY SPECIAL COMMON MATERIALS Chemical Name Health Flammability Reactivity Special Acetone 2 3 0 Acetylene 1 4 2 Acetylene Argon (compressed) 1 0 0 Aromatic hydrocarbon 2 3 0 (paint thinner) Carbon dioxide (compressed) 1 0 0 Chlorine gas 3 0 0 OXY Diesel Fuel 0 2 0 Ethylene glycol (antifreeze) 1 0 0 Freon Refrigerant 2 0 0 Gasoline 1 3 0 Helium (compressed) 1 0 0 Hydrogen (compressed) 1 4 0 Isopropyl alcohol 2 3 0 Kerosene 1 2 0 Lead Acid Batteries 2 0 0 Muriatic Acid (hydrochloric) 3 0 0 Nitrogen (compressed) 1 0 0 Nitrous Oxide 1 0 2 OXY Oil 0 1 0 Oxygen (compressed) 1 0 0 OXY Oxygen (cryogenic) 3 0 0 OXY Propane (LPG) 2 4 0 Safety Kleen Parts Cleaner 1 2 0 Sodium Hydroxide 3 0 1 Stoddard solvent (part cleaner) 2 2 0 Sulfuric Acid 3 0 2 W *For materials not listed above please see product manufacturer data sheet* WFPD January 2020 .
Recommended publications
  • Health Hazard Flammability Instability
    Health Hazard Very short exposure could cause death or serious 4 residual injury even though prompt medical attention was given. Short exposure could cause serious temporary or 3 residual injury even though prompt medical attention was given. Intense or continued exposure could cause temporary 2 incapacitation or possible residual injury unless prompt medical attention is given. Exposure could cause irritation but only minor residual 1 injury even if no treatment is given. Exposure under fire conditions would offer no hazard 0 beyond that of ordinary combustible materials. Flammability Will rapidly or completely vaporize at normal pressure 4 and temperature, or is readily dispersed in air and will burn readily. Liquids and solids that can be ignited under almost all 3 ambient conditions. Must be moderately heated or exposed to relatively high 2 temperature before ignition can occur. 1 Must be preheated before ignition can occur. 0 Materials that will not burn. Instability1 Readily capable of detonation or of explosive 4 decomposition or reaction at normal temperatures and pressures. Capable of detonation or explosive reaction, but 3 requires a strong initiating source or must be heated under confinement before initiation, or reacts Normally unstable and readily undergo violent decomposition but do not detonate. Also: may react 2 violently with water or may form potentially explosive mixtures with water. Normally stable, but can become unstable at elevated 1 temperatures and pressures or may react with water with some release of energy, but not violently. 0 Normally stable, even under fire exposure conditions, Special Hazards This section is used to denote special hazards.
    [Show full text]
  • Laboratory Safety for Chemistry Students
    LABORATORY SAFETY FOR CHEMISTRY STUDENTS ROBERT H. HILL, JR. DAVID C. FINSTER A JOHN WILEY & SONS, INC., PUBLICATION LABORATORY SAFETY FOR CHEMISTRY STUDENTS LABORATORY SAFETY FOR CHEMISTRY STUDENTS ROBERT H. HILL, JR. DAVID C. FINSTER A JOHN WILEY & SONS, INC., PUBLICATION Copyright 2010 by John Wiley & Sons, Inc. All rights reserved Published by John Wiley & Sons, Inc., Hoboken, New Jersey Published simultaneously in Canada No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, scanning, or otherwise, except as permitted under Section 107 or 108 of the 1976 United States Copyright Act, without either the prior written permission of the Publisher, or authorization through payment of the appropriate per-copy fee to the Copyright Clearance Center, Inc., 222 Rosewood Drive, Danvers, MA 01923, (978) 750-8400, fax (978) 750-4470, or on the web at www.copyright.com. Requests to the Publisher for permission should be addressed to the Permissions Department, John Wiley & Sons, Inc., 111 River Street, Hoboken, NJ 07030, (201) 748-6011, fax (201) 748-6008, or online at http://www.wiley.com/go/permission. Limit of Liability/Disclaimer of Warranty: While the publisher and author have used their best efforts in preparing this book, they make no representations or warranties with respect to the accuracy or completeness of the contents of this book and specifically disclaim any implied warranties of merchantability or fitness for a particular purpose. No warranty may be created or extended by sales representatives or written sales materials.
    [Show full text]
  • National Fire Protection Association Pamphlet 704 Identification of Hazard Materials for Emergency Response
    SAN BERNARDINO COUNTY FIRE DEPARTMENT COMMUNITY SAFETY/HAZARDOUS MATERIALS DIVISION “STANDARDS FOR INTERPRETATIONS” NATIONAL FIRE CODES AND THE CALIFORNIA FIRE CODE STANDARD NUMBER 704 NATIONAL FIRE PROTECTION ASSOCIATION PAMPHLET 704 IDENTIFICATION OF HAZARD MATERIALS FOR EMERGENCY RESPONSE I SCOPE: This standard, in conjunction with N.F.P.A. pamphlet 704 currently adopted, shall address the health, flammability, instability, and related hazards that are presented by short term, acute exposure to a material under conditions of fire, spill, or similar emergencies. II PURPOSE: The purpose of this standard is to provide identification of fire hazard and to placard all businesses that have storage were certain minimum quantity of hazard material exists. III LOCATION: 1. The identification placard shall be located on the outside of buildings and/or storage tanks in locations deemed appropriate by fire department staff. Inside placarding shall be required when chemicals are segregated into separate areas. 2. The material safety data sheet (MSDS) should have the information on hazard ratings to be used for each material. Community Safety staff shall approve the placard numbering. 3. The acceptable sizes of NFPA 704 signs are: 4 inches on each side with 2 inch symbol (interior posting) 10 inches on each side with 4 inch symbols for buildings less than 100,000 ft2 15 inches on each side with 6 inch symbols for buildings greater than 100,000 ft2 4. Letters shall be a minimum of four (4) inches high by three (3) inches wide by 5/8-inch stroke. 5. The number or symbol indication in each colored category shall reflect the most severe hazard associated with any hazardous materials at the business or in the area indicated by the posting.
    [Show full text]
  • Technical Committee on Classification and Properties of Hazardous
    Technical Committee on Classification and Properties of Hazardous Chemical Data NFPA 704 First Draft Meeting Agenda October 24, 2019 2:00 PM-4:00 PM Eastern Time Web Meeting/Teleconference 1. Call to Order, Ron Kirsch, Chair 2. Introductions. 3. Approval of Meeting Minutes from October 13, 2015 (Attachment A). 4. Staff Updates. Debra Gursha, NFPA Staff • Committee membership update. (Attachment B) • Annual 2021 revision cycle schedule. (Attachment C) • Overview of NFPA Process. 5. Task Group Updates: • DSC-Differential Scanning Calorimetry (DSC) related to Annex E and Table 7.2 • Combustible Dust definitions related to NFPA 652 6. Review of Public Inputs. NFPA 704 (Attachment D) 7. New Business. 8. Next Meeting. 9. Adjourn. TECHNICALCOMMITTEEON ClassificationandPropertiesofHazardousChemicalData MINUTES SecondDraftMeeting October13,2015 10AMͲ1PMEDT ConferenceCall/AdobeConnectMeeting Attendees: RonKirsch,Chair RobertMichaels JasonBeam LarryBritton LauraDraelos WalterGroden DavidHollinger KennethLewis CarolineMiller DavidPhelan BrianPrimeau GaryRobinson DavidWechsler CynthiaWernet JenniferLawless NancyPearce,NFPAStaff Guests: BrianO’Connor,NFPAStaff BrendaPrine,RetiredDowChemical KeithHarrison,UniversityofAlabama 1. RonKirsch,Chair,welcomedtheCommitteeandguests.Themeetingbeganpromptly at10AMEDT. 2. Attendancewastakenandguestintroducedthemselves. 3. TheFirstDraftMeetingMinutesfromSeptember23,2014wereapproved. 4. NancygaveaPowerPointpresentationontheseconddraftmeetingprocessthat includedanupdateonCommitteemembership,areviewofthemeetingmotionsand
    [Show full text]
  • Bayer Cropscience
    Bayer CropScience Safety Data Sheet SDS Number: 102000013572 SENCOR® 480 F FLOWABLE HERBICIDE SDS Version 2.1 Revision Date: 04/04/2013 Print Date: 05/09/2013 SECTION 1. CHEMICAL PRODUCT AND COMPANY INFORMATION Product name SENCOR® 480 F FLOWABLE HERBICIDE SDS Number 102000013572 Product code (UVP) 04886011 PCP Registration No. 26280 Product Use Herbicide Bayer CropScience Inc #200, 160 Quarry Park Blvd, SE Calgary, Alberta T2C 3G3 Canada For MEDICAL, TRANSPORTATION or other EMERGENCY call: 1-800-334-7577 (24 hours/day) For Product Information call: 1-888-283-6847 SECTION 2. HAZARDS IDENTIFICATION NOTE: Please refer to Section 11 for detailed toxicological information. Emergency Overview Caution! Harmful if swallowed, inhaled or absorbed through the skin. Avoid contact with skin, eyes and clothing. Avoid breathing dust or spray mist. Physical State liquid suspension Odor weak characteristic Appearance white to grey-beige Exposure routes Eye contact, Skin Absorption, Inhalation, Ingestion Immediate Effects Eye Mild eye irritation. Avoid contact with eyes. Skin Slight irritation Avoid contact with skin and clothing. Ingestion Harmful if swallowed. Do not take internally. Inhalation May be harmful if inhaled. Chronic or Delayed This product or its components may have target organ effects. Long-Term Page 1 of 10 Bayer CropScience Safety Data Sheet SDS Number: 102000013572 SENCOR® 480 F FLOWABLE HERBICIDE SDS Version 2.1 SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS Hazardous Component Name CAS-No. Average % by Weight Metribuzin 21087-64-9 41.00 Fatty acid methyl tauride sodium salt 137-20-2 1.18 Glycerine 56-81-5 15.00 SECTION 4. FIRST AID MEASURES General When possible, have the product container or label with you when calling a poison control center or doctor or going for treatment.
    [Show full text]
  • Understanding NFPA Labeling
    120 White Bridge Rd. Nashville, TN 37209 Understanding National Fire Protection Association (NFPA) Labeling NFPA Diamond Labeling System HEALTH Deadly: even the slightest exposure to this substance would be life threatening. Only specialized 4 protective clothing, for these materials, should be worn. Extreme Danger: serious injury would result from exposure to this substance. Do not expose 3 anybody surface to these materials. Full protective measures should be taken. Dangerous: exposure to this substance would be hazardous to health. Protective measures are 2 indicated. Slight Hazard: irritation or minor injury would result from exposure to this substance. Protective 1 measures are indicated. 0 No Hazard: exposure to this substance offers no significant risk to health. FLAMMABILITY Flash Point Below 73ºF and Boiling Point Below 100ºF: this substance is very flammable, volatile or 4 explosive depending on its state. Extreme caution should be used in handling or storing of these materials. Flash Point Below 100ºF: flammable, volatile or explosive under almost all normal temperature 3 conditions. Exercise great caution in storage or handling of these materials. Flash Point Below 200ºF: moderately heated conditions may ignite this substance. Caution 2 procedures should be employed in handling. Flash Point Above 200ºF: this substance must be preheated to ignite. Most combustible solids would 1 be in this category. 0 Will Not Burn: substances that will not burn. REACTIVITY May Detonate: substances that are readily capable of detonation or explosion at normal 4 temperatures and pressures. Evacuate area if exposed to heat or fire. Explosive: substances that are readily capable of detonation or explosion by a strong initiating 3 source, such as heat, shock or water.
    [Show full text]
  • Safety Data Sheet Tetrino
    SAFETY DATA SHEET TETRINO 1/10 Version 1.0 / CDN Revision Date: 03/31/2020 102000032078 Print Date: 03/31/2020 SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING Product identifier Trade name TETRINO Product code (UVP) 84500089 SDS Number 102000032078 PCP Registration No. 33714 Relevant identified uses of the substance or mixture and uses advised against Use Insecticide Restrictions on use See product label for restrictions. Information on supplier Supplier Bayer CropScience Inc #200, 160 Quarry Park Blvd, SE Calgary, Alberta T2C 3G3 Canada Responsible Department Email: [email protected] Emergency telephone no. Emergency Telephone 1-800-334-7577 Number (24hr/ 7 days) Product Information 1-888-283-6847 Telephone Number SECTION 2: HAZARDS IDENTIFICATION Classified in accordance with Part 2 of the Hazardous Products Regulations This material is not hazardous under the criteria of Part 2 of the Hazardous Products Regulation. Hazards Not Otherwise Classified (HNOC) No physical hazards not otherwise classified. No health hazards not otherwise classified. SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS Hazardous Component Name CAS-No. Concentration % by weight Tetraniliprole 1229654-66-3 4.07 Sodium diisopropylnaphthalene sulphonate 1322-93-6 1.0 SAFETY DATA SHEET TETRINO 2/10 Version 1.0 / CDN Revision Date: 03/31/2020 102000032078 Print Date: 03/31/2020 SECTION 4: FIRST AID MEASURES Description of first aid measures General advice When possible, have the product container or label with you when calling a poison control center or doctor or going for treatment. Inhalation Move to fresh air. If person is not breathing, call 911 or an ambulance, then give artificial respiration, preferably mouth-to-mouth if possible.
    [Show full text]
  • Fd Spec #25 Exhibit 1 Nfpa 704 Frequently Asked Questions
    FD Specification #25 Standard for Hazardous Materials Storage, Dispensing, Use, Handling & Disposal (Exhibit 1) NFPA 704: Standard System for the Identification of the Hazards of Materials for Emergency Response Frequently Asked Questions 1. What is NFPA 704? NFPA 704 provides a simple, readily recognized, easily understood system for identifying the specific hazards of a material and the severity of the hazard that would occur during an emergency response. The system addresses the health, flammability, instability, and special hazards presented from short‐term, acute exposures that could occur as a result of a fire, spill, or similar emergency. The Lake Havasu City Fire Department endorses this standard. Please read and use the information in this document along with the NFPA 704 Warning Placard Requirements document to properly mark your building/facility/premises. (See Question 14 for additional information) 2. How does the 704 label differ from other hazardous material labels? There are several widely used systems for labeling hazardous materials. Each has a specific purpose and it is important to recognize the differences between each. Table 1 provides a brief summary of the purpose and use of three common labeling systems used for hazardous materials. Note that you may see more than one label on a container depending on the situation. (See Question 12 for additional information on the differences between OSHA HazCom 2012 classifications and NFPA 704 ratings) 3. What information on the SDS do I use to rate my hazardous materials? The ratings can be determined by using the information found on a HazCom 2012 compliant Safety Data Sheet (SDS), formerly known as MSDS, and comparing it to the criteria provided in NFPA 704.
    [Show full text]
  • SDS # : 001180 Supplier's Details : Airgas USA, LLC and Its Affiliates 259 North Radnor-Chester Road Suite 100 Radnor, PA 19087-5283 1-610-687-5253
    SAFETY DATA SHEET ARGON, REFRIGERATED LIQUID Section 1. Identification GHS product identifier : ARGON, REFRIGERATED LIQUID Chemical name : Argon Refrigerated Liquid Other means of : Cryogenic Liquid Argon, Liquid Argon identification Product type : Liquefied gas Product use : Synthetic/Analytical chemistry. Synonym : Cryogenic Liquid Argon, Liquid Argon SDS # : 001180 Supplier's details : Airgas USA, LLC and its affiliates 259 North Radnor-Chester Road Suite 100 Radnor, PA 19087-5283 1-610-687-5253 24-hour telephone : 1-866-734-3438 Section 2. Hazards identification OSHA/HCS status : This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200). Classification of the : GASES UNDER PRESSURE - Refrigerated liquefied gas substance or mixture GHS label elements Hazard pictograms : Signal word : Warning Hazard statements : Contains refrigerated gas; may cause cryogenic burns or injury. May cause frostbite. May displace oxygen and cause rapid suffocation. Precautionary statements General : Read and follow all Safety Data Sheets (SDS’S) before use. Read label before use. Keep out of reach of children. If medical advice is needed, have product container or label at hand. Close valve after each use and when empty. Use equipment rated for cylinder pressure. Do not open valve until connected to equipment prepared for use. Use a back flow preventative device in the piping. Use only equipment of compatible materials of construction. Always keep container in upright position. Do not change or force fit connections. Avoid spills. Do not walk or roll equipment over spills. Prevention : Wear cold insulating gloves and face shield. Use and store only outdoors or in a well ventilated place.
    [Show full text]
  • Download the Carbon Dioxide Liquid (Airgas) Safety Data Sheet
    SAFETY DATA SHEET Carbon Dioxide Section 1. Identification GHS product identifier : Carbon Dioxide Chemical name : Carbon dioxide Other means of : Carbonic, Carbon Dioxide, Carbonic Anhydride, R744, Carbon Dioxide USP identification Product use : Synthetic/Analytical chemistry. Synonym : Carbonic, Carbon Dioxide, Carbonic Anhydride, R744, Carbon Dioxide USP SDS # : 001013 Supplier's details : Airgas USA, LLC and its affiliates 259 North Radnor-Chester Road Suite 100 Radnor, PA 19087-5283 1-610-687-5253 24-hour telephone : 1-866-734-3438 Section 2. Hazards identification OSHA/HCS status : This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200). Classification of the : GASES UNDER PRESSURE - Liquefied gas substance or mixture Simple asphyxiant. GHS label elements Hazard pictograms : Signal word : Warning Hazard statements : Contains gas under pressure; may explode if heated. May cause frostbite. May displace oxygen and cause rapid suffocation. May increase respiration and heart rate. Precautionary statements General : Read and follow all Safety Data Sheets (SDS’S) before use. Read label before use. Keep out of reach of children. If medical advice is needed, have product container or label at hand. Close valve after each use and when empty. Use equipment rated for cylinder pressure. Do not open valve until connected to equipment prepared for use. Use a back flow preventative device in the piping. Use only equipment of compatible materials of construction. Always keep container in upright position. Prevention : Use and store only outdoors or in a well ventilated place. Response : Not applicable. Storage : Protect from sunlight when ambient temperature exceeds 52°C/125°F. Store in a well- ventilated place.
    [Show full text]
  • HEALTH HAZARD DATA Division
    MATERIAL LindeAGA GAS, Gas LLCINC. (216) 642-6600 SAFETY P.O.6055 Box ROCKSIDE 94737 WOODS BLVD DATA SHEET Cleveland,P.O. BOX 94737 Ohio 44101 www.us.lindegas.comCLEVELAND, OH 44101-4737 PRODUCT NAME CAS # 7664-41-7 Ammonia DOT I.D. No.: TRADE NAME AND SYNONYMS UN 1005 RQ 100 (45.5) Ammonia, Anhydrous (D.O.T.) DOT Hazard Class: Division 2.2 CHEMICAL NAME AND SYNONYMS Formula Ammonia NH3 ISSUE DATES AND REVISIONS Chemical Family: Nitrogen Hydride Revised March 1998 HEALTH HAZARD DATA TIME WEIGHTED AVERAGE EXPOSURE LIMIT TWA = 25 Molar PPM; STEL = 35 Molar PPM (ACGIH 1997,). OSHA 1995 PEL (8 hr. TWA) 50 Molar PPM. SYMPTOMS OF EXPOSURE Corrosive and irritating to the skin, eyes, upper respiratory system and all mucosal tissue. Depending on the concentration inhaled, it may cause burning sensations, coughing, wheezing, shortness of breath, headache, nausea, with eventual collapse. Mild concentrations of vapor will cause dermatitis or conjunctivitis. Higher concentrations of vapor or liquid contact will cause caustic-like dermal burns and inflammation and swelling of the eyes with possible loss of vision. Rapidly evaporating liquid contacting dermal tissue or the eyes can cause cryoqenic “burns.” TOXICOLOGICAL PROPERTIES Inhalation: Affects the upper airway (larynx and bronchi) by causing caustic-like burning resulting in edema and chemical pneumonitis. If it enters the deep lung, pulmonary edema will result. Toxic level exposure to dermal tissue causes caustic-like burns and skin lesions resulting in early necrosis and scarring. Burns to the eye result in lesions and possible loss of vision. Cryogenic “burns” are like frostbite with a change in skin color to gray or white possibly followed by blistering.
    [Show full text]
  • NFPA 704 Markings
    704 MARKING SYSTEM The NFPA 704 Marking System is a system developed by the National Fire Protection Association to alert emergency personnel of the type and degree of hazards within an area enabling them to more easily decide whether to evacuate the area or to commence control procedures. The Virginia Fire Prevention Code requires the use of this system to identify the contents of stationary containers and above-ground storage tanks and to identify locations where hazardous materials are stored, dispensed, used or handled in quantities requiring an Operational Permit. Storage tanks of 300 gallons capacity or less used for heating and cooking fuels at single-family homes are exempted from this requirement. When displayed: Used for hazards in facilities and may be found on non-bulk packaging. How displayed: The system uses a diamond shaped symbol, positioned on point, divided into four smaller diamonds. Symbol description: The four smaller diamond shapes or quadrants have specific meanings as follows: • Blue quadrant (left) indicates health hazard • Red quadrant (top) indicates health hazard • Yellow quadrant (right) indicates reactivity hazard • Lower quadrant (bottom) contains symbols indicating special hazards, such as OXY for oxidizers, radioactive trefoil (propeller), W for water reactive materials Degree of Hazard: Each of the colored quadrants contains a number from 0 to 4 indicating the relative degree of hazard of the material stored in the container or area. NFPA 704 MARKING SYSTEM HEALTH HAZARD FLAMMABILITY HAZARD REACTIVITY